Loading...
HomeMy WebLinkAboutSFADD2025-003149Survey (not to scale) Area Map (not to scale) P. 469.510.7672 | www.valekdesign.com 1901 Cedar Ridge Circle Ennis, TX 75119 Sheet Title Cover Sheet Number E. valek.jw@gmail.com J.W.Valek Building Designer August 5, 2025 None Scale None Owner Sidney Suzette Fenton 2510 Lone Star Lane Grapevine, TX 76051 Property Address 2510 Lone Star Lane Grapevine, TX 76051 Date Placid Penninsula Addition Block 10, Lot 12A Legal Description Proposal for existing patio cover permit Scope of Work: Construct new cover for existing hardscape in backyard (attached to existing residence) (previously not permitted) Apply for permit to allow previous rear patio cover (drawings attached) Area of New Structure: 150 SF Table of Contents Cover: Scope of Work, Survey, Area Map S1: Plan for patio cover addition/elevation/electrical Intended Purpose of Structure: Cover existing hardscape in backyard w/ roof covering attached to existing residence (previously completed without permit...replacing existing open top "arbor") No changes to lot coverage area(s) Rob and Sidney Suzette Fenton No changes to impervious area(s) Revised Area of Modification Bottom of Header 2:12 Pitch Metal Roofing Existing Brick Veneer Existing/no changes Existing/no changes Existing Window Existing Door (Addition) Existing Residence Existing Residence w/Patio Roof Covering Shown Cover Existing Patio Double 2 x 12 Laminated Header Wrapped in Cedar (@8') 2:12 Pitch Metal Roofing (Addition) Roof to be framed w/ 2 x 6s 24" o.c. (typical) Roof Plan Showing New Roof Over Existing Patio FlatworkRoof Plan Before Patio Cover Addition Rear Elevation Showing New Patio Cover Addition P. 469.510.7672 | www.valekdesign.com 1901 Cedar Ridge Circle Ennis, TX 75119 Sheet Title Plan/Elevation/ Electrical Sheet Number E. valek.jw@gmail.com J.W.Valek Building Designer August 5, 2025 S1 Scale 1 4 " = 1' Owner Sidney Suzette Fenton 2510 Lone Star Lane Grapevine, TX 76051 Property Address 2510 Lone Star Lane Grapevine, TX 76051 Date Placid Penninsula Addition Block 10, Lot 12A Legal Description ROOF FRAMING PLAN NOTES – TEXAS NEW ROOF FRAMING - New roof rafters shall be 2x6 SPF #2 or better, spaced at 24" o.c. - Provide full-depth birdsmouth cuts at exterior wall plates. - Rafters shall bear a minimum of 1½" on top plate. - Rafters to be securely fastened with (2) 16d nails at each bearing. TIE-IN TO EXISTING ROOF STRUCTURE - New rafters to tie into existing roof rafters using approved hanger brackets (e.g., Simpson LRU210 or equivalent) or properly notched and lag-screwed into existing framing as required. - Verify existing framing dimensions and spacing prior to tie-in. Field modifications must be approved by the structural designer. - Maintain structural continuity across ridge and valley connections where applicable. - Install collar ties or rafter ties where required to resist uplift and lateral thrust. ROOF SHEATHING - Roof sheathing shall be 1/2" APA-rated plywood, Exposure 1, installed perpendicular to rafters with staggered joints. - Use 8d nails at 6" o.c. on edges and 12" o.c. in the field, unless otherwise noted. - All panel edges must be supported by blocking or framing members. ROOF UNDERLAYMENT - Install two layers of ASTM D226 Type II roofing underlayment or approved synthetic equivalent, installed in accordance with manufacturer’s specifications and local code. - Overlap horizontal seams a minimum of 4", end laps 6", and fasten per manufacturer’s requirements. ROOF COVERING - Roof covering shall be standing seam metal roofing with minimum 24 ga. panels and concealed fasteners. - Panels must be installed over underlayment with approved clips and trim profiles. - Provide all manufacturer-specified flashings at hips, valleys, ridges, eaves, and penetrations. - Ensure proper ventilation per IRC Section R806.2. STRUCTURAL CONNECTIONS - All connections to existing framing shall use approved mechanical connectors (e.g., hangers, straps) as required by uplift and lateral force calculations. - Fasteners must meet Texas windstorm requirements, if in coastal or high-wind zone. - Coordinate all structural work with the existing conditions and framing layout. GENERAL NOTES - Contractor shall field-verify all dimensions and existing conditions before starting work. - All work shall comply with the 2021 International Residential Code (IRC) as adopted and amended by the State of Texas or applicable local jurisdiction. - Notify architect/engineer of any discrepancies prior to construction. Existing Flatwork w/ open top "arbor" Eave to match existing High Mount GFCI GFCI Rest double 2x12s on top of existing 8' top plate Rest double 2x12s on top of existing 8' top plate Wrap in cedar 25' Building Line Revised