HomeMy WebLinkAboutSladden Residence IFC - 2025 06 23Scale
Date
G.0
COVER SHEET
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
Sheet List
Sheet
Number Sheet Name
Sheet Issue
Date
G.0 COVER SHEET 06/18/2025
G.1 CODE SHEET/SPECIFICATIONS 06/18/2025
G.2 SPECIFICATIONS 06/18/2025
G.3 SPECIFICATIONS 06/18/2025
G.4 SPECIFICATIONS 06/18/2025
G.5 SPECIFICATIONS 06/18/2025
EXH-1 DRAINAGE PLAN 06/18/2025
S0.0 GENERAL NOTES 06/18/2025
S0.1 TYPICAL FRAMING DETAILS 06/18/2025
S0.2 TYPICAL FRAMING DETAILS 06/18/2025
S0.3 TYPICAL FRAMING SCHEDULE 06/18/2025
S0.4 TYPICAL FRAMING SCHEDULE 06/18/2025
S0.5 TYPICAL FRAMING SCHEDULE 06/18/2025
S1.0 FOUNDATION PLAN 06/18/2025
S1.1 FOUNDATION DETAILS 06/18/2025
S1.2 1ST FLOOR SHEARWALL PLAN 06/18/2025
S1.3 2ND FLOOR SHEARWALL PLAN 06/18/2025
S1.4 1ST FLOOR CEILING & 2ND FLOOR FRAMING PLAN 06/18/2025
S1.5 2ND FLOOR CEILING FRAMING PLAN 06/18/2025
S1.6 ROOF FRAMING PLAN 06/18/2025
A1.1 ARCHITECTURAL SITE PLAN 06/18/2025
No. Description Date
Sheet List
Sheet
Number Sheet Name
Sheet Issue
Date
A1.2 GROUND LEVEL - DEMOLITION PLAN 06/18/2025
A1.3 SECOND LEVEL - DEMOLITION PLAN 06/18/2025
A2.1 GROUND LEVEL - FLOOR PLAN 06/18/2025
A2.2 SECOND LEVEL - FLOOR PLAN 06/18/2025
A2.3 ROOF PLAN 06/18/2025
A3.1 GROUND LEVEL - REFLECTED CEILING PLAN 06/18/2025
A3.2 SECOND LEVEL - REFLECTED CEILING PLAN 06/18/2025
A4.1 EXTERIOR ELEVATIONS 06/18/2025
A4.2 EXTERIOR ELEVATIONS 06/18/2025
A4.3 BUILDING SECTIONS 06/18/2025
A5.1 WALL SECTIONS 06/18/2025
A6.1 INTERIOR ELEVATIONS 06/18/2025
A7.1 SECTION DETAILS 06/18/2025
A7.2 SECTION DETAILS 06/18/2025
A7.3 SECTION DETAILS 06/18/2025
A7.4 BATHROOM DETAILS 06/18/2025
E1.1 GROUND LEVEL - ELECTRICAL PLAN 06/18/2025
E1.2 SECOND LEVEL - ELECTRICAL PLAN 06/18/2025
SLADDEN RESIDENCE
06/18/2025
PROJECT INFORMATION
HOUSE AREA:LEVEL 1 LEVEL 2
EXISTING:1,532 SF 1,482 SF
EXISTING GARAGE:457 SF
DEMO:N/A 416 SF
NEW:649 SF 1,150 SF
TOTAL AREA PER FLOOR:2,181 SF 2,216 SF
TOTAL HOUSE AREA: 4,397 SF
LOT AREA: 12,500 SF
MAX LOT COVERAGE ALLOWED: 40% (5,000 SF)
TOTAL LOT COVERAGE:2,947 SF
MAX IMPERVIOUS AREA ALLOWED: 60% ALLOWED (7,500 SF)
REVISED GROUND LEVEL HOUSE AREA: 2,946 SF
EXISTING FLATWORK: 2,573 SF
TOTAL IMPERVIOUS AREA:5,519 SF
APPLICABLE CODES:
2021 INTERNATIONAL RESIDENTIAL CODE
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL MECHANICAL CODE
2020 NATIONAL ELECTRIC CODE
Scale
Date
G.1
CODE
SHEET/SPECIFICATIONS
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
SECTION 00 21 13 — INSTRUCTIONS TO BIDDERS
PART 1 — GENERAL
1.01 PROJECT DESCRIPTION
A. This project is located on a 0.28-acre lot at 2803 Highcrest Drive in Grapevine, Texas. The existing house is constructed of wood framing. The
exterior finish materials are brick and painted wood siding with an asphalt shingle roof. There is currently a living room, dining room, kitchen, four
bedrooms including the master, three bathrooms, an office, laundry room, garage, exterior patio, and exterior deck. The scope of the project is to
demolish the existing deck and patio that is located plan south of the garage, demolish the existing room and floor assembly above the garage,
construct a two story addition where the deck and patio was located, above the garage to create a bedroom with an en suite, a work space, and
studio room, and design a carport to the plan west of the existing garage.
Work includes all general construction, site work, architectural finishes, and coordination with MEP trades as indicated in the construction
documents.
1.02 BID DOCUMENTS
A. Bid documents include:
1. Project Drawings (Architectural, Structural)
2. Specifications included on sheets
3. Addenda (if issued)
4. This Section (Instructions to Bidders)
B. All documents may be obtained from the Owner, Christa Sladden in electronic PDF format.
1.03 EXAMINATION OF DOCUMENTS AND SITE
A. Bidders shall visit the project site and become familiar with existing conditions.
B. No allowances will be made for lack of knowledge of site conditions.
C. Coordinate site visits with Owner at (817) 239-9471.
1.04 BID FORMAT AND REQUIREMENTS
A. Submit a complete lump sum bid on form similar to AIA A701
B. Include:
1. Base Bid
2. Allowances (if required)
3. Unit Prices (if requested)
4. Alternates (if applicable)
5. Schedule of Values
1.05 BID SUBMISSION
A. Bids must be received by:
Date and time stated by Owner
Provide required bid documents to the Owner via email
sladdc@gmail.com
B. Late bids will not be accepted.
1.06 QUESTIONS AND SUBSTITUTIONS
A. All questions must be submitted in writing to the Architect.
B. Substitution requests must include full product data and comparison.
C. Approved substitutions will be issued via Addendum.
1.07 ADDENDA
A. Addenda will be issued no later than 3 days before the bid due date.
B. Bidders must acknowledge receipt of all addenda on the Bid Form.
1.08 WITHDRAWAL OR MODIFICATION OF BIDS
A. Bids may be modified or withdrawn prior to the deadline.
B. No bid may be withdrawn for 30 days after the bid date.
1.11 AWARD AND CONTRACT
A. The Owner reserves the right to reject any or all bids and to waive irregularities.
B. The successful bidder will be required to sign AIA Document A105 (or another Owner-approved agreement) and begin work per the
approved schedule.
1.12 SCHEDULE
A. Work is anticipated to begin on or about [Insert Start Date].
B. Substantial completion is expected within [Insert number] calendar days.
GENERAL CONDITIONS — DESIGN PROFESSIONAL & INSURANCE REQUIREMENTS
1. THIRD-PARTY BENEFICIARY
A. The Design Professional (Architect), identified in the Agreement and/or Contract Documents, shall be deemed a third-party beneficiary of this
Agreement solely with respect to matters pertaining to the Contractor’s obligations to the Client and the performance of the Work.
B. The Contractor acknowledges that the Design Professional has rights to enforce provisions of this Agreement that affect the integrity, quality,
timeliness, or conformance of the Work with the Contract Documents.
C. Nothing in this clause shall give the Design Professional authority to direct or control the means, methods, or safety procedures of the Contractor,
which remain the Contractor’s sole responsibility.
2. INSURANCE AND ADDITIONAL INSUREDS
A. The Contractor shall maintain Commercial General Liability (CGL) Insurance with limits not less than:
$1,000,000 per occurrence
$2,000,000 general aggregate
$2,000,000 products-completed operations aggregate
B. The Contractor shall name both the Client (Owner) and the Design Professional (Architect) as Additional Insureds under the CGL policy for both
ongoing and completed operations. Coverage shall be provided on a primary and non-contributory basis.
C. The Contractor shall provide certificates of insurance and endorsements evidencing the Additional Insured status before the start of Work and
upon renewal or request.
D. The insurance shall include a Waiver of Subrogation in favor of the Owner and Architect and shall remain in effect for the duration of the
construction and any applicable warranty period.
4. SECURITY: OBTAIN THROUGH OWNER, REQUIRED SECURITY CLEARANCES, ACCESS ARRANGEMENTS, PASSES OR BADGES
NECESSARY FOR CONTRACTOR'S WORKMEN, SUBCONTRACTORS, AND SUPPLIERS WHO MAY REQUIRE ACCESS DURING
CONSTRUCTION. COOPERATE WITH OWNER REGARDING AREAS OF LIMITED ACCESS
5. WASTE REMOVAL: MAINTAIN PROJECT SITE IN CLEAN AND ORDERLY CONDITION. REMOVE ALL RUBBISH AND WASTE MATERIAL ON
REGULAR BASIS AND EXERCISE STRICT CONTROL OVER JOB CLEANING TO PREVENT DIRT, DEBRIS, OR DUST FROM AFFECTING
FINISHED AREAS INSIDE OR OUTSIDE JOBSITE.
A. AT SUBSTANTIAL COMPLETION, LEAVE PREMISES AND ALL SURFACES AND FIXTURES FINISHED, CLEANED, ORDERLY, AND
READY FOR MOVE-IN.
6. CONSTRUCTION OFFICE:
A. PROVIDE AND MAINTAIN FIELD CONSTRUCTION OFFICE, AS DIRECTED BY OWNER, WHERE CITY-APPROVED COPY OF
CONSTRUCTION DOCUMENTS, CURRENT SET OF RECORD DRAWINGS, AND SAMPLES OF ALL FINISHES ARE KEPT.
7. PROTECTION OF EXISTING FACILITIES:
A. PROTECT EXISTING VEGETATION, EQUIPMENT, STRUCTURES, UTILITIES AND OTHER IMPROVEMENTS, EXCEPT AS
INDICATED TO BE REMOVED OR ALTERED.
B. COMPLY WITH ENVIRONMENTAL REGULATIONS AND MINIMIZE AIR, WATERWAY, SUBSOIL CONTAMINATION OR POLLUTION
OR OTHER UNDESIRABLE EFFECTS.
C. STORMWATER CONTROL: COMPLY WITH REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION (AHJ). PROVIDE
BARRIERS AS REQUIRED TO PREVENT RUNOFF OF STORMWATER FROM HEAVY RAINS.
D. MAINTAIN SITE, EXCAVATIONS, AND CONSTRUCTION FREE OF STANDING WATER. MINIMIZE ACCUMULATION OF SNOW AND
ICE.
8. USE OF PREMISES: CONFINE CONTRACTOR'S APPARATUS, DELIVERY AND STORAGE OF MATERIALS, AND OPERATIONS TO LIMITS
DEFINED BY OWNER.
9. TEMPORARY FIRE-PROTECTION: PROHIBIT SMOKING IN CONSTRUCTION AREAS. SUPERVISE WELDING OPERATIONS, TEMPORARY
HEATING, AND OTHER SOURCES OF FIRE IGNITION ACCORDING TO REQUIREMENTS OF AHJ.
10. MOISTURE AND MOLD CONTROL: PROTECT MATERIALS SUBJECT TO WATER ABSORPTION OR MOLD GROWTH. DISCARD
MATERIALS WITH WATER DAMAGE OR THAT HAVE MOLD. PERFORM WORK IN SEQUENCE THAT ALLOWS WET MATERIALS ADEQUATE
TIME TO DRY BEFORE ENCLOSING WITH OTHER CONSTRUCTION.
G. PRODUCT REQUIREMENTS
1. SINGLE SOURCE COMPATIBILITY: WHERE POSSIBLE, AND SUBJECT TO MANUFACTURER ACCEPTANCE AND WARRANTY
REQUIREMENTS, PROVIDE THE SAME PRODUCT COMPONENTS FOR DIFFERENT ASSEMBLIES, FOR EXAMPLE, SEALANT,
WATERPROOFING, PENETRATION FIREPROOFING.
2. PROVIDE PRODUCTS THAT ARE NEW AND UNDAMAGED, UNLESS SPECIFICALLY PERMITTED BY CONTRACT DOCUMENTS.
3. DO NOT USE PRODUCTS THAT:
A. ARE MADE USING OR CONTAINING CFC OR HCFC.
B. CONTAIN LEAD, CADMIUM, OR ASBESTOS.
C. CONTAIN ADDED UREA FORMALDEHYDE
4. WHERE DIRECTED BY OWNER, AND SUBJECT TO IMPACT ON CONTRACT SUM OR CONSTRUCTION SCHEDULE, GIVE
CONSIDERATION TO PRODUCTS THAT HAVE LOWER VOC EMISSIONS, HAVE RECYCLED CONTENT, AND/OR THAT ARE SUSTAINABLY
HARVESTED, PROVIDED ALL OTHER CRITERIA SPECIFIED ARE MET. SALVAGE, RE-USE, OR RECYCLE NON-HAZARDOUS
CONSTRUCTION MATERIALS WHERE POSSIBLE.
5. PRODUCT OPTIONS:
A. WHERE PRODUCTS ARE INDICATED BY THE TERM "AS SELECTED", ARCHITECT WILL MAKE SELECTION.
B. WHERE BASIS OF DESIGN PRODCTS OR PRODUCTS NAMED WITH A LMITED LIST OF MANUFACTURERS ARE INDICATED,
PROVICE ONLY THOSE PRODUCTS, UNLESS EQUIVALENT PRODUCST BY OTHER MANUFACTURERS ARE ALSO PERMITTED.
C. WHERE ONLY A LIMITED LIST OF MANUFACTURERS IS INDICATED, PROVIDE PRODUCTS FROM ONE OF THOSE
MANUFACTURERS THAT COMPLIES WITH REQUIREMENTS, UNLESS EQUIVALENT PRODUCTS BY OTHER MANUFACTURERS
ARE ALSO PERMITTED.
D. WHERE A SOLE PRODUCT IS NAMED AND NO OTHER MANUFACTURER OR PRODUCT IS LISTED, SUBSTITUTIONS WILL NOT
BE ACCEPTED, UNLESS EQUIVALENT PRODUCTS BY OTHER MANUFACTURERS ARE ALSO PERMITTED.
E. FOR EQUIVALENT PRODUCTS BY OTHER MANUFACTURERS, ARCHITECT WILL CONSIDER CONTRACTOR'S REQUEST FOR
COMPARABLE PRODUCTS, IF PROPOSED PRODUCTS ARE CONSISTENT WITH THE CONTRACT DOCUMENTS, WILL PRODUCE
THE INDICATED RESULTS, ARE COMPATIBLE WITH OTHER PARTS OF THE WORK, AND MEET WARRANTY REQUIREMENTS.
SUBMIT DETAILED COMPARISON OF PROPOSED PRODUCTS WITH NAMED PRODUCTS, AND SAMPLES IF APPLICABLE, FOR
REVIEW AND APPROVAL.
F. PRODUCTS SPECIFIED BY REFERENCE STANDARDS OR BY DESCRIPTION ONLY: USE ANY PRODUCT MEETING THOSE
STANDARDS OR DESCRIPTION.
G. FINISHES, COLORS, TEXTURES, AND PATTERNS ARE INDICATED ON DRAWINGS. WHERE NOT INDICATED, OR NOTED BY
THE TERM "AS SELECTED", ARCHITECT WILL MAKE SELECTION.
6. WARRANTIES
A. WARRANTIES SPECIFIED IN OTHER SECTIONS SHALL BE IN ADDITION TO, AND RUN CONCURRENT WITH, OTHER
WARRANTIES REQUIRED BY CONTRACT DOCUMENTS
B. MANUFACTURER'S DISCLAIMERS AND LIMITATIONS ON PRODUCT WARRANTIES DO NOT RELIEVE CONTRACTOR OF
OBLIGATIONS UNDER REQUIREMENTS OF THE CONTRACT DOCUMENTS.
7. DELIVERY, STORAGE, HANDLING AND PROTECTION:
A. COORDINATE DELIVERY OF PRODUCTS TO AVOID LENGTHY LEAD TIMES THAT MIGHT DELAY PROJECT, TO MINIMIZE SITE
STORAGE TIME, AND TO MINIMIZE PROTECTION OF POTENTIAL DAMAGE TO STORED MATERIALS.
B. PROVIDE PROTECTION OF STORED MATERIALS AND PRODUCTS AGAINST THEFT, CASULATY, OR DEERIORATION.
C. STRUCTURAL LOADING LIMITATIONS: HANDLE AND STORE PRODUCTS AND MATERIALS SO AS NOT TO EXCEED STATIC AND
DYNAMIC LOAD-BEARING CAPACITIES OF BUILDING FLOORS AND ROOFS.
H. EXECUTION & CLOSEOUT
1. USE OF EXPLOSIVES IS PROHIBITED
2. PROTECT SITE FROM PUDDLING OR RUNNING WATER. PREVENT EROSION AND SEDIMENTATION.
3. VENTILATION AND DUST CONTROL: VENTILATE ENCLOSED AREAS TO ASSIST CURE OF MATERIALS, TO DISSIPATE HUMIDITY, AND
TO PREVENT ACCUMULATION OF DUST, FUMES, VAPORS, OR GASES.
A. USE METHODS TO MINIMIZE DUST FROM CONSTRUCTION OPERATIONS.
4. PEST AND RODENT CONTROL: PROVIDE METHODS, MEANS, AND FACILITIES TO CONTROL RODENTS, INSECTS, AND OTHER PESTS
DURING CONSTRUCTION.
5. POLLUTION CONTROL: COMPLY WITH FEDERAL, STATE, AND LOCAL REGULATIONS TO PREVENT CONTAMINATION OF SOIL, WATER,
AND AIR FROM POLLUTANTS DUE TO CONSTRUCTION OPERATIONS.
6. EXAMINATION: VERIFY THAT EXISTING CONDITIONS AND SUBSTRATES ARE ACCEPTABLE FOR SUBSEQUENT WORK. BEGINNING OF
WORK MEANS ACCEPTANCE OF EXISTING CONDITIONS.
7. LAYOUT OF WORK:
A. PROMPTLY NOTIFY ARCHITECT OF ANY DISCREPANCIES DISCOVERED.
8. GENERAL INSTALLATION REQUIREMENTS
A. INSTALL PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS, AND SO AS TO
AVOID WASTE DUE TO NECESSITY FOR REPLACEMENT.
B. MAKE VERTICAL ELEMENTS PLUMB AND HORIZONTAL ELEMENTS LEVEL, UNLESS OTHERWISE INDICATED
C. INSTALL EQUIPMENT AND FITTINGS PLUMB AND LEVEL, NEATLY ALIGNED WITH ADJACENT VERTICAL AND HORIZONTAL
LINES, UNLESS OTHERWISE INDICATED. D. MAKE CONSISTENT TEXTURE ON SURFACES, WITH SEAMLESS TRANSITIONS,
UNLESS OTHERWISE INDICATED
E. MAKE NEAT TRANSITIONS BETWEEN DIFFERENT SURFACES, MAINTAINING TEXTURE AND APPEARANCE.
9. CUTTING AND PATCHING: EXECUTE WORK WHERE POSSIBLE BY METHODS THAT MINIMIZE CUTTING OR PATCHING. WHERE
CUTTING AND PATCHING IS NECESSARY, FINISH PATCHED SURFACES TO MATCH FINISH THAT EXISTED PRIOR TO PATCHING.
REPLACE IF WORK IS NOT TO SATISFACTION OF OWNER AND ARCHITECT.
10. PROGRESS CLEANING: MAINTAIN PROJECT SITE IN A CLEAN AND ORDERLY CONDITION. REMOVE WASTE MATERIALS, DEBRIS,
AND TRASH ON A DAILY BASIS. DO NOT BURY OR BURN.
11. ADJUST OPERATING PRODUCTS AND EQUIPMENT TO ENSURE SMOOTH AND UNHINDERED OPERATION.
12. FINAL CLEANING: EXECUTE FINAL CLEANING PRIOR TO SUBSTANTIAL COMPLETION.
A. FOLLOW MANUFACTURER RECOMMENDATIONS ON ITEMS TO BE CLEANED. USE NONHAZARDOUS CLEANING MATERIALS
WHERE POSSIBLE.
B. REMOVE WASTE, SURPLUS MATERIALS, TRASH, AND CONSTRUCTION FACILITIES FROM SITE. DISPOSE OF IN LEGAL
MANNER, DO NOT BURN OR BURY.
13. PROTECTION OF INSTALLED WORK: PROVIDE TEMPORARY AND REMOVABLE PROTECTION FOR INSTALLED PRODUCTS. CONTROL
ACTIVITY IN IMMEDIATE WORK AREA TO PREVENT DAMAGE.
14. CLOSEOUT PROCEDURES: NOTIFY ARCHITECT WHEN CONTRACTOR'S WORK IS NEARING COMPLETION.
A. PREPARE A PRELIMINARY LIST OF DEFICIENCIES (PUNCHLIST) OUTLINING INCOMPLETE WORK. ACCOMPANY ARCHITECT
ON PRELIMINARY INSPECTION. ARCHITECT SHALL REVIEW LIST OF DEFICIENCIES AND NOTE ANY ADDITIONAL
UNACCEPTABLE WORK AND ITEMS NEEDING ATTENTION.
B. TOUCH UP UP AND OTHERWISE REPAIR A R AND RESTORE MARRED EXPOSED FINISHES TO ELIMINATE VISUAL DEFECTS.
C. SUBMIT WARRANTIES, MAINTENANCE SERVICE AGREEMENTS, FINAL CERTIFICATIONS, AND SIMILAR DOCUMENTS.
D. PREPARE AND SUBMIT PROJECT RECORD DOCUMENTS, OPERATION AND MAINTENANCE MANUALS, WARRANTIES, AND
OTHER FINAL RECORD INFORMATION.
E. DELIVER SPARE PARTS, ATTIC STOCK, AND SIMILAR ITEMS TO OWNER.
F. MAKE FINAL CHANGEOVER OF PERMANENT LOCKS AND DELIVER KEYS TO OWNER. ADVISE OWNER OF CHANGEOVER IN
SECURITY PROVISIONS.
G. CORRECT ITEMS OF WORK LISTED IN PUNCHLIST AND NOTIFY ARCHITECT WHEN WORK IS CONSIDERED FINALLY
COMPLETE AND READY FOR ARCHITECT'S SUBSTANTIAL COMPLETION FINAL INSPECTION.
SECTION 010000 GENERAL REQUIREMENTS
A. GENERAL
1. GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION FORM AIA A201-2017 SHALL BE INCORPORATED INTO THE
CONTRACT DOCUMENTS. OWNER- CONTRACTOR AGREEMENT SHALL GOVERN, IF GENERAL CONDITIONS CONFLICT WITH THE
AGREEMENT.
A. THE USE OF THE WORD "PROVIDE" IN CONNECTION WITH ANY ITEM SPECIFIED IS INTENDED TO MEAN THAT SUCH ITEMS
SHALL BE FURNISHED, INSTALLED, AND CONNECTED BY CONTRACTOR, EXCEPT NOTED OTHERWISE.
B. CONTRACTOR SHALL ACKNOWLEDGE IN WRITING, THAT HE HAS READ AND REVIEWED CONSTRUCTION DOCUMENTS
INFORMATION CONTAINED IN GENERAL CONDITIONS. THEIR ENTIRETY INCLUDING ALL
C. NOTHING CONTAINED IN DRAWINGS OR IN ANY ACCOMPANYING CONTRACT DOCUMENTS SHALL CREATE ANY
CONTRACTUAL RELATIONSHIP BETWEEN CONTRACTOR AND ARCHITECT.
D. CONTRACTOR SHALL PURCHASE AND MAINTAIN LIABILITY INSURANCE FOR DURATION OF PROJECT AS INDICATED IN AIA
A201-2017, ARTICLE 11. CERTIFICATES OF INSURANCE ACCEPTABLE TO OWNER SHALL BE FILED WITH OWNER AND INCLUDE
OWNER, ARCHITECT, AND ARCHITECT'S CONSULTANTS AS ADDITIONAL
2. SHOULD ANY CONTRADICTION, AMBIGUITY, ERROR, OR INCONSISTENCY APPEAR IN OR BETWEEN ANY OF THE CONTRACT
DOCUMENTS, NOTIFY ARCHITECT AND REQUEST INTERPRETATION BEFORE PROCEEDING WITH WORK IN QUESTION.
A. DIMENSIONS AND DESCRIPTIONS ON CONSTRUCTION DRAWINGS ARE COMPLIMENTARY. WORK SHOWN OR REFERRED
TO ON ANY CONSTRUCTION DOCUMENT SHALL BE PROVIDED AS THOUGH ON ALL RELATED DOCUMENTS.
B. DO NOT DIRECTLY MEASURE OR "SCALE DRAWINGS TO ASCERTAIN ANY DIMENSION. CLARIFY DIMENSIONS IN CONFLICT
OR NOT NOTED, WITH ARCHITECT
3. EXISTING CONDITIONS:
A. INFORMATION RELATING TO EXISTING SURFACE, SUBSURFACE CONDITIONS AND ANY EXISTING STRUCTURES WILL BE
PROVIDED DIRECTLY BY OWNER.
B. PRIOR TO BEGINNING WORK, EXAMINE SITE AND PORTIONS THEREOF WHICH WILL AFFECT WORK AND COMPARE WITH
DRAWINGS TO VERIFY CONDITIONS UNDER WHICH WORK IS TO BE PERFORMED.
C. NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCIES IN EXISTING CONDITIONS PRIOR TO BEGINNING CONSTRUCTION.
WORK IN PROBLEM AREAS SHALL NOT PROCEED UNTIL APPROVED BY ARCHITECT. PROCEEDING WITH WORK SHALL
CONSTITUTE ACCEPTANCE OF PROJECT CONDITIONS.
4. WORK BY OWNER: COOPERATE FULLY WITH OWNER TO MINIMIZE CONFLICTS, WITHOUT INTERFERING WITH OR DELAYING WORK
UNDER THIS CONTRACT OR WORK BY OWNER. COORDINATE WORK UNDER THIS CONTRACT WITH WORK PERFORMED BY OWNER.
5. CONTRACTOR SHALL HAVE LIMITED USE OF PROJECT SITE FOR CONSTRUCTION OPERATIONS DURING CONSTRUCTION PERIOD.
CONTRACTOR’S USE OF SITE IS LIMITED ONLY BY OWNER’S RIGHT TO PERFORM WORK.
6. LANGUAGE CONVENTIONS: IMPERATIVE MOOD AND STREAMLINED LANGUAGE ARE GENERALLY USED IN THE DRAWINGS.
B. PRICE & PAYMENT PROCEDURES
1. SUBMIT SCHEDULE OF VALUES WITHIN 10 DAYS AFTER DATE SCHEDULED FOR SUBMITTAL OF INITIAL APPLICATIONS FOR
PAYMENT. SUBMITTED SCHEDULE OF VALUES SHALL BE BASED ON FORMAT OF AIA DOCUMENT G703. PROVIDE A BREAKDOWN OF
CONTRACT SUM IN ENOUGH DETAIL TO FACILITATE CONTINUED EVALUATION OF APPLICATION FOR PAYMENT AND PROGRESS
REPORTS.
2. APPLICATION FOR PAYMENT: SUBMIT AT INTERVALS STIPULATED IN THE AGREEMENT, ON PAYMENT FORM BASED ON AIA G702
AND AIA G703. FOLLOW BREAKDOWN OF THE CONTRACT SUM FROM THE SCHEDULE OF VALUES AND INCLUDE AMOUNTS OF
CHANGE ORDERS AND CONSTRUCTION CHANGE DIRECTIVES AS APPROPRIATE.
A. WITH EACH APPLICATION, SUBMIT WAIVERS OF MECHANIC'S LIENS FROM ENTITIES LAWFULLY ENTITLED TO FILE A
MECHANIC'S LIEN ARISING OUT OF CONTRACT, RELATED TO WORK COVERED BY THE PAYMENT.
C. SUBSTITUTIONS
1. SUBSTITUTIONS FOR SPECIFIED PRODUCTS, ASSEMBLIES, MATERIALS, AND EQUIPMENT SHALL BE EQUIVALENT TO OR BETTER
THAN THAT SPECIFIED, WITH AT LEAST THE SAME WARRANTY, AND SUBJECT TO REVIEW AND WRITTEN ACCEPTANCE BY
ARCHITECT.
A. ARCHITECT MAY REQUEST ADDITIONAL INFORMATION PRIOR TO RENDERING A DECISION.
B. ACCEPTED SUBSTITUTIONS CHANGE THE NATURE OF THE WORK AND MUST BE DOCUMENTED WITH COMPLETE DATA
SUBSTANTIATING COMPLIANCE WITH CONTRACT DOCUMENTS.
D. ADMINISTRATIVE REQUIREMENTS
1. PROJECT MEETINGS: SCHEDULE REGULAR AND PERIODIC MEETINGS AS APPROPRIATE.
A. ATTENDANCE SHALL BE BY RELEVANT PARTIES AS APPROPRIATE, INCLUDING CONTRACTOR, OWNER, ARCHITECT,
SUBCONTRACTORS, SUPPLIERS, AND OTHERS.
B. RECORD MINUTES INCLUDING SIGNIFICANT PROCEDURES AND DECISIONS. DISTRIBUTE COPIES OF MINUTES WITHIN 4
DAYS AFTER EACH MEETING TO THOSE AFFECTED BY DECISIONS.
2. CONSTRUCTION PROGRESS SCHEDULE: PRIOR TO BEING AWARDED CONTRACT, PREPARE AND SUBMIT TO ARCHITECT,
ESTIMATED PROGRESS SCHEDULE OF THE WORK.
3. CONTRACTOR IS RESPONSIBLE FOR SECURING PERMITS FOR ALL PHASES OF THE WORK, AS REQUIRED BY FEDERAL, STATE,
COUNTY, AND MUNICIPAL LAW. 4. REQUESTS FOR INFORMATION (RFI):
A. PREPARE AN RFI IMMEDIATELY UPON DISCOVERY OF A NEED FOR INTERPRETATION OF CONTRACT DOCUMENTS.
B. ARCHITECT WILL RESPOND AND RETURN RFI TO CONTRACTOR WITHIN 7 CALENDAR DAYS OF RECEIPT.
5. SUBMITTALS:
A. SUBMIT THE FOLLOWING TO ARCHITECT FOR REVIEW FOR THE LIMITED PURPOSE OF CHECKING COMPLIANCE WITH
DESIGN CONCEPT OF PROJECT AND GENERAL COMPLIANCE WITH INFORMATION IN THE CONTRACT DOCUMENTS, WHEN
SPECIFIED IN INDIVIDUAL SECTIONS: PRODUCT DATA, SHOP DRAWINGS, AND SAMPLES FOR SELECTION OR FOR
VERIFICATION.
B. SUBMIT THE FOLLOWING TO ARCHITECT FOR INFORMATION ONLY, WHEN SPECIFIED IN INDIVIDUAL SECTIONS: DESIGN
DATA, CERTIFICATES, TEST AND INSPECTION REPORTS, AND MANUFACTURER'S FIELD REPORTS.
C. REVIEW AND STAMP ALL SUBMITTALS. SUBMITTALS WHICH DO NOT BEAR CONTRACTOR'S APPROVAL STAMP SHALL BE
RETURNED WITHOUT REVIEW.
D. ARCHITECT WILL REVIEW AND RETURN TO CONTRACTOR MARKED "APPROVED", "REVISE AND RESUBMIT", "REJECTED",
"RECEIVED, OR OTHER APPROPRIATE ACTION. ADDITIONAL INFORMATION IS
E. ARCHITECT SHALL HAVE 10 WORKING DAYS FOR REVIEW OF EACH SHOP DRAWING. RESPONSE TIME MAY BE ADJUSTED,
REQUIRED, OR IF ARCHITECT'S CONSULTANTS ARE TO REVIEW SUBMITTALS.
F. REVIEW OF SUBMITTALS IS NOT FOR DETERMINING THE ACCURACY AND COMPLETENESS OF OTHER DETAILS SUCH AS
DIMENSIONS AND QUALITIES, OR FOR SUBSTANTIATING INSTRUCTIONS FOR INSTALLATION OR PERFORMANCE OF
EQUIPMENT OR SYSTEMS, ALL OF OF WHICH REMAIN RESPONSIBILITY OF CONTRACTOR.
G. ARCHITECT'S REVIEW SHALL NOT CONSTITUTE APPROVAL OF SAFETY PRECAUTIONS OR OF ANY CONSTRUCTION
MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES. ARCHITECT'S ACCEPTANCE OF A SPECIFIC ITEM SHALL
NOT INDICATE APPROVAL OF AN ASSEMBLY OF WHICH ITEM IS A COMPONENT.
H. CONTRACTOR SHALL PERFORM NO PORTION OF THE WORK REQUIRING SUBMITTAL AND REVIEW UNTIL THE RESPECTIVE
SUBMITTAL HAS BEEN REVIEWED BY ARCHITECT. SUCH WORK SHALL BE IN ACCORDANCE WITH APPROVED SUBMITTALS.
J. CONTRACTOR SHALL NOT BE RELIEVED OF RESPONSIBILITY FOR DEVIATIONS FROM REQUIREMENTS OF THE CONTRACT
DOCUMENTS BY ARCHITECT'S REVIEW UNLESS CONTRACTOR HAS SPECIFICALLY INFORMED ARCHITECT IN WRITING OF
SUCH DEVIATION AT TIME OF SUBMITTAL AND ARCHITECT HAS GIVEN WRITTEN ACCEPTANCE TO THE SPECIFIC DEVIATION.
CONTRACTOR SHALL NOT BE RELIEVED OF RESPONSIBILITY FOR ERRORS OR OMISSIONS IN SUBMITTALS BY ARCHITECTS
ACCEPTANCE THEREOF.
E. QUALITY REQUIREMENTS
1. CONTRACTOR'S PROFESSIONAL DESIGN SERVICES: PROVIDE ENGINEERING DESIGN SERVICES FOR CONSTRUCTION
ASSEMBLIES INDICATED IN INDIVIDUAL SECTIONS, BASED ON PERFORMANCE AND/OR DESIGN CRITERIA. ENGINEER MUST BE
EXPERIENCED IN DESIGN OF THE TYPE OF WORK SPECIFIED AND LICENSED IN STATE IN WHICH PROJECT IS LOCATED
2. WORK SHALL INCLUDE ALL LABOR, ASSEMBLIES, AND FINISH WORK WITH ALL PARTS AND MATERIAL NECESSARY TO MAKE A
COMPLETE, IN-PLACE, PROPERLY WORKING, AND FINISHED INSTALLATION, WHETHER OR NOT SHOWN ON DRAWINGS.
3. WORK SHALL BE DONE WITH THE FINEST WORKMANSHIP IN ACCEPTANCE WITH INDUSTRY STANDARDS FOR CONSTRUCTION,
FABRICATION, AND INSTALLATION FOR EACH TRADE. USE ONLY NEW HIGHEST QUALITY MATERIALS CONSISTENT WITH
SPECIFICATIONS. COMPLY WITH ALL APPLICABLE BUILDING CODES, AND FEDERAL STATE, AND LOCAL GOVERNMENT
REGULATIONS, INCLUDING THOSE DEALING WITH ENERGY, ADA REQUIREMENTS, FACTORY MUTUAL, AND UNDERWRITERS
LABORATORIES STANDARDS.
A. MONITOR QUALITY CONTROL OVER SUPPLIERS, MANUFACTURERS, PRODUCTS, SERVICES, SITE CONDITIONS, AND
WORKMANSHIP.
B. VERIFY QUALITY CUREMENTS ARE AS INDICATED ON SHOP DRAWINGS OR AS INSTRUCTED BY THE MANUFACTURER.
C. MONITOR FABRICATION AND INSTALLATION TOLERANCE CONTROL OF PRODUCTS TO PRODUCE ACCEPTABLE WORK. DO
NOT PERMIT TOLERANCES TO ACCUMULATE.
4. MANUFACTURER'S FIELD AND TECHNICAL SERVICES: WHEN SPECIFIED IN INDIVIDUAL SECTIONS, PROVIDE QUALIFIED STAFF
PERSONNEL TO OBSERVE AND INSPECT WORK AS APPLICABLE AND TO INITIATE INSTRUCTIONS AS NECESSARY.
F. TEMPORARY FACILITIES & CONTROLS
1. TEMPORARY UTILITIES: PROVIDE AND PAY FOR ALL ELECTRICAL POWER, LIGHTING, WATER, HEATING AND COOLING, AND
VENTILATION REQUIRED, UNLESS PROVIDED BY OWNER FOR USE BY CONTRACTOR.
A. USE OF GASOLINE-BURNING SPACE HEATERS, OPEN-FLAME HEATERS OR SALAMANDER-TYPE HEATING UNITS IS
PROHIBITED.
B. INTERRUPTION OF SERVICES: AVOID IF POSSIBLE, AND IF UNAVOIDABLE, MINIMIZE IMPACT OF INTERRUPTION OR
SHUTDOWN OF ELECTRICAL, MECHANICAL, PLUMBING, OR TELEPHONE SERVICES. OWNER SHALL BE NOTIFIED 48 HOURS IN
ADVANCE BEFORE SHUTDOWN OCCURS.
2. TEMPORARY SANITATION: PROVIDE TEMPORARY TOILETS, WASH FACILITIES, AND DRINKING WATER FOR USE BY CONSTRUCTION
PERSONNEL. MAINTAIN IN CLEAN AND SANITARY CONDITION.
3. BARRIERS: WHERE DIRECTED BY OWNER OR ARCHITECT, PROVIDE TEMPORARY BARRIERS AND CLOSURES TO PREVENT
UNAUTHORIZED ENTRY, TO PREVENT ACCESS TO POTENTIALLY HAZARDOUS AREAS, AND TO PROTECT EXISTING FACILITIES AND
NEW CONSTRUCTION.
A. DAMAGE TO NEW AND EXISTING MATERIAL, FINISHES, STRUCTURES, AND EQUIPMENT SHALL BE REPAIRED OR
REPLACED AT NO ADDITIONAL EXPENSE TO OWNER.
No. Description Date
06182025
Scale
Date
G.2
SPECIFICATIONS
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
a.
b.
c.
d.
SECTION 031535 UNDERSLAB VAPOR BARRIER
A SEE ARCHITECTURAL DRAWINGS FOR EXTENT OF WORK.
B. PERFORMANCE REQUIREMENTS:
1. WATER VAPOR PERMEANCE: NOT MORE THAN 0.010 PERMS, MAXIMUM,
2. COMPLY WITH ASTM E1745, CLASS A.
3. THICKNESS: 15 MILS.
C. ACCEPTABLE PRODUCTS:
1. EQUIVALENT PRODUCTS NOT LISTED BELOW BY OTHER MANUFACTURERS SHALL COMPLY WITH THIS SECTION AND BE
SUBJECT TO REVIEW AND APPROVAL BY ARCHITECT:
A. STEGO WRAP VAPOR BARRIER (15-MIL) BY STI STEGO INDUSTRIES (WWW.STEGOINDUSTRIES.COM).
2. ACCESSORY PRODUCTS: VAPOR BARRIER MANUFACTURER'S RECOMMENDED TAPE, ADHESIVE, MASTIC, ETC., FOR
SEALING SEAMS AND PENETRATIONS IN VAPOR BARRIER.
D. EXAMINATION:
1. VERIFY THAT SURFACE OVER WHICH VAPOR BARRIER IS TO BE INSTALLED IS READY BEFORE PROCEEDING WITH
INSTALLATION OF VAPOR BARRIER.
2. DO NOT PROCEED UNTIL UNDER-SLAB PLUMBING AND ELECTRICAL ROUGH-IN WORK IS COMPLETE, AND SPECIFIED FILL OR
SUBGRADE MATERIAL HAS BEEN PLACED, COMPACTED, AND TESTED; AND IS LEVEL AND WITHOUT VOIDS.
E. INSTALLATION:
1. INSTALL VAPOR BARRIER IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND ASTM E1643.
2. INSTALL VAPOR BARRIER UNDER INTERIOR SLABS ON GRADE. LAP SHEET OVER FOOTINGS AND SEAL TO FOUNDATION
WALLS.
3. LAP JOINTS MINIMUM 6 INCHES.
4. SEAL JOINTS, SEAMS AND PENETRATIONS WATERTIGHT WITH MANUFACTURER'S RECOMMENDED PRODUCTS.
5. NO PENETRATION OF VAPOR BARRIER IS ALLOWED EXCEPT FOR REINFORCING STEEL AND PERMANENT UTILITIES.
6. REPAIR DAMAGED VAPOR RETARDER BEFORE COVERING WITH OTHER MATERIALS.
F. PROTECTION:
1. DO NOT PERMIT UNNECESSARY FOOT OR VEHICULAR TRAFFIC ON UNPROTECTED HORIZONTAL MEMBRANE.
2. PROTECT COMPLETE MEMBRANE FROM DAMAGE. PRIOR TO POURING CONCRETE, INSPECT MEMBRANE FOR PUNCTURES
OR DAMAGE AND REPAIR AS REQUIRED TO MAINTAIN VAPOR RETARDER INTEGRITY.
Section 03 54 00 – Gypsum Cement Underlayment
(Includes Acoustical Mat and Perimeter Isolation Strip)
Part 1 – General
1.1 Summary
Provide sound control underlayment system consisting of Maxxon AcoustiMat®, perimeter isolation strip, and poured Gyp-Crete®
topping over subfloor or concrete slab to reduce impact and airborne sound transmission in multi-family or residential construction.
1.2 Submittals
Manufacturer’s product data for AcoustiMat, Gyp-Crete, and isolation strip
Acoustical performance test data (ASTC/IIC ratings)
MSDS for all components
Installation instructions and details
Part 2 – Products
2.1 Manufacturers
Basis of Design: Maxxon Corporation
AcoustiMat® [Specify Type I, II, or 3/4]
Gyp-Crete® [Specify 2000/3.2K or as required]
Perimeter Isolation Strip by Maxxon
2.2 Materials
Acoustical Mat:
Sound control mat with entangled mesh core and non-woven fabric backing
Mat thickness: [Specify 1/8", 1/4", or 3/8"]
STC/IIC Performance: When used in system, STC and IIC ≥ 50 (field) or 60 (lab) as required by code
Gypsum Underlayment:
Gyp-Crete® gypsum-based cementitious floor underlayment
Minimum compressive strength: 2,000 psi (standard residential)
Applied over AcoustiMat at min. 3/4" thickness or per system specification
Perimeter Isolation Strip:
Closed-cell foam or equivalent to decouple underlayment from vertical surfaces
Height: Minimum to extend above finished Gyp-Crete pour
Part 3 – Execution
3.1 Preparation
Clean and prime subfloor as recommended by Maxxon
Install perimeter isolation strip along all vertical interfaces
Unroll AcoustiMat and secure per manufacturer’s recommendations
Overlap fabric seams and seal per specification to prevent gypsum intrusion
3.2 Installation
Pour Gyp-Crete over AcoustiMat to specified thickness
Ensure full encapsulation of mat without displacement
Allow to cure per manufacturer’s guidelines (typically 5–7 days before light foot traffic)
Protect from heavy loads, water, or contamination during curing
3.3 Field Quality Control
Verify pour thickness and acoustical mat coverage
Remove isolation strip protruding above floor before final flooring installation
Conduct field sound tests if required
SECTION 04 20 00 — UNIT MASONRY
PART 1 — GENERAL
1.1 SUMMARY
A. Provide all labor, materials, tools, equipment, and services necessary for the installation of modular face brick masonry as indicated on
drawings.
B. Work includes:
1. Modular face brick veneer or full masonry walls
2. Mortar, reinforcement, ties, mortar net, and accessories
3. Flashing, weep holes, and control joints
1.2 BASIS OF DESIGN
A. Modular face brick, nominal size approximately 3-5/8" x 2-1/4" x 7-5/8" (modular size).
B. Color, texture, and finish as selected by Owner from manufacturer samples within allowance.
1.3 ALLOWANCE
A. Material allowance of $6.00 per square foot of installed brick veneer (brick only, excluding mortar, labor, reinforcement, and accessories).
B. Any selection exceeding the allowance shall be submitted to Owner for approval and paid as an upgrade via change order.
1.4 SUBMITTALS
A. Manufacturer’s product data and technical specifications.
B. Color and texture samples for Owner approval.
C. Sample of mortar color to match existing masonry.
D. Mockup panel (if required) showing typical brickwork, mortar joint, flashing, anchors, and weep holes.
1.5 QUALITY ASSURANCE
A. Comply with ASTM C216 for face brick or ASTM C652 for solid masonry units.
B. Install in accordance with the latest edition of the TMS 402/602 Building Code Requirements and Specification for Masonry Structures or
local building code.
C. Use experienced masons with proven track record.
PART 2 — PRODUCTS
2.1 FACE BRICK
A. Modular face brick conforming to ASTM C216, Type FBS (Face Brick, Solid), Grade SW (Severe Weather).
B. Size: Modular (nominal 3-5/8" x 2-1/4" x 7-5/8").
C. Color and texture: As selected by Owner within allowance.
D. Strength: Minimum compressive strength per ASTM C216.
2.2 MORTAR
A. Type: ASTM C270 Type N or Type S mortar as required for structural and weather exposure conditions.
B. Color: Mortar color to match existing masonry as closely as possible. Provide sample for approval.
2.3 ACCESSORIES
A. Flashing:
1. Self-adhered flexible flashing membrane or metal flashing as per project details.
2. Installed at all shelf angles, lintels, sills, and base of masonry to direct water out of cavity.
B. Mortar Net:
1. Provide corrosion-resistant mortar net or cavity drainage mat in the air space behind the veneer as per manufacturer’s recommendations.
C. Anchors and Ties:
1. Provide corrosion-resistant anchors complying with ASTM A82 (steel) or ASTM A666 (stainless steel).
2. Typical anchor type: adjustable masonry veneer anchors or corrosion-resistant wire anchors.
3. Spacing: Minimum 4.5 anchors per square yard (approx. 16" o.c. horizontally by 16" o.c. vertically), adjusted per structural engineer’s
specifications.
4. Anchor placement: Embed securely into backup wall or framing and securely attached to veneer per manufacturer and code
requirements.
D. Weep Holes:
1. Provide weep holes at base of veneer and above flashing locations.
2. Weep holes shall be spaced maximum 24" o.c. or per local code.
3. Use open head joints or plastic weep vents with corrosion-resistant wire mesh to prevent pest entry.
PART 3 — EXECUTION
3.1 PREPARATION
A. Verify substrate is clean, plumb, level, and structurally sound.
B. Coordinate with flashing and waterproofing trades to ensure continuous drainage plane.
3.2 INSTALLATION
A. Install brick veneer with uniform mortar joints (typically 3/8"), maintaining bond pattern.
B. Mortar color shall match approved sample and be consistent throughout installation.
C. Install flashing continuously at all shelf angles, lintels, and base of veneer to direct moisture out.
D. Install mortar net in cavity behind veneer to facilitate drainage.
E. Install anchors per specified spacing and securely attach to structural backup.
F. Provide weep holes at required intervals to allow drainage and ventilation.
G. Tool mortar joints to consistent profile after initial set.
3.3 CLEANING
A. Remove mortar droppings and smears promptly using manufacturer-approved cleaning methods.
B. Protect finished masonry from damage and staining until final acceptance.
SECTION 061053 MISCELLANEOUS ROUGH CARPENTRY
A. SEE ARCHITECTURAL DRAWINGS FOR EXTENT OF WORK.
B. QUALITY ASSURANCE
1. WOOD PRODUCTS SHALL HAVE MAXIMUM MOISTURE CONTENT OF 15%
2. FIRE RETARDANT TREATED LUMBER AND PLYWOOD BY PRESSURE PROCESS: PRODUCTS WITH FLAME SPREAD INDEX OF
25 OR LESS WHEN TESTED ACCORDING TO ASTM E84, AND WITH NO EVIDENCE OF SIGNIFICANT PROGRESSIVE
COMBUSTION WHEN TEST IS EXTENDED AN ADDITIONAL 20 MINUTES, AND WITH FLAME FRONT NOT EXTENDING MORE THAN
10.5 FEET BEYOND THE CENTERLINE OF BURNERS AT ANY TIME DURING TEST.
C. STORAGE AND HANDLING: STACK LUMBER FLAT WITH SPACERS BENEATH AND BETWEEN EACH BUNDLE TO PROVIDE AIR
CIRCULATION. PROTECT LUMBER AND PLYWOOD FROM WEATHER BY COVERING WITH WATERPROOF SHEETING, SECURELY
ANCHORED.
D. PRODUCTS:
1. ROUGH CARPENTRY:
A. SILLS ON CONCRETE: DOUGLAS FIR WITH PRESERVATIVE TREATMENT.
B. SILL SEALER GASKET: EPDM STRUCTURAL SILL GASKET WITH RAISED BULB ENDS BY CONSERVATION
TECHNOLOGY (WWW.CONSERVATIONTECHNOLGY.COM) OR EQUIVALENT BY OTHER MANUFACTURER. SIZE AS
REQUIRED FOR WIDTH OF SILL FRAMING.
C. LUMBER (WOOD FRAMING): MATERIAL GRADE AS SHOWN ON DRAWINGS.
D. PROVIDE MISCELLANEOUS LUMBER BLOCKING AND FURRING AT CONCEALED LOCATIONS FOR SUPPORT OR
ATTACHMENT OF OTHER CONSTRUCTION.
2. PLYWOOD AND OSB: PROVIDE THICKNESS AND GRADE AS FOLLOWS, UNLESS OTHERWISE INDICATED IN DRAWINGS.
MINIMUM 5 PLY FOR PLYWOOD THICKNESS 15/32 INCH OR GREATER.
A. WALL SHEATHING: 7/16 INCH OSB PANELS.
B. BUILDING SUB-FLOOR: 1-1/8 INCH EXTERIOR PLYWOOD, TONGUE AND GROOVE. SECURE TO FLOOR JOISTS WITH
LIQUID NAILS ADHESIVE AND SCREW TO FRAMING
C. ROOF DECKING: 3/4 INCH OSB ROOF DECKING WITH APA 24/16 SPAN RATING.
D. ATTIC SUB-FLOORING FOR A/C UNITS: 3/4 INCH C-D EXTERIOR PLYWOOD TO ACCOMMODATE A/C EQUIPMENT AND
SERVICE AREA.
E. TRAFFICABLE PATH IN ATTIC SPACE: 3/4 INCH C-D EXTERIOR PLYWOOD TO ACCOMMODATE STORAGE.
F. PLYWOOD EQUIPMENT BACKING PANELS: 3/4 INCH PLYWOOD, DOC PS 1. A-C EXTERIOR, FIRE RETARDANT
TREATED.
G. OTHER EXPOSED FINISH PLYWOOD: 3/4 INCH A2, LUMBER CORE BIRCH PLYWOOD, UNLESS OTHERWISE
INDICATED.
3. FASTENERS:
A. ALL EXTERIOR HARDWARE SHALL BE HOT-DIPPED GALVANIZED.
B. NAILS, BRADS, AND STAPLES: ASTM F1667.
C. SCREWS FOR FASTENING TO METAL FRAMING: ASTM C1002 OR ASTM C954, LENGTH AS RECOMMENDED BY
SCREW MANUFACTURER FOR MATERIAL BEING FASTENED.
D. POST-INSTALLED ANCHORS: STAINLESS STEEL WITH BOLTS AND NUTS COMPLYING WITH ASTM F593 AND ASTM
F594, ALLOY GROUP 1 OR 2.
4. ADHESIVES FOR GLUING FURRING TO CONCRETE OR MASONRY: COMPLYING WITH ASTM D3498 AND APPROVED
FOR USE INDICATED BY ADHESIVE MANUFACTURER.
E. WOOD-PRESERVATIVE TREATED MATERIALS:
1. PRESERVATIVE TREATMENT BY PRESSURE PROCESS: AWPA U1; USE CATEGORY UC2 FOR INTERIOR CONSTRUCTION NOT
IN CONTACT WITH THE GROUND, CATEGORY UC3B FOR EXTERIOR CONSTRUCTION NOT IN CONTACT WITH THE GROUND,
AND CATEGORY UC4A FOR ITEMS IN CONTACT WITH THE GROUND.
A. PRESERVATIVE CH E CHEMICALS: ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION AND CONTAINING NO
ARSENIC OR CHROMIUM. DO NOT USE INORGANIC BORON (SBX) FOR SILL PLATES.
F. FIRE-RETARDANT-TREATED MATERIALS: PRODUCTS WITH FLAME SPREAD INDEX OF 25 OR LESS WHEN TESTED ACCORDING TO
ASTM E84, AND WITH NO EVIDENCE OF SIGNIFICANT PROGRESSIVE COMBUSTION WHEN TEST IS EXTENDED AN ADDITIONAL 20
MINUTES, AND WITH FLAME FRONT NOT EXTENDING MORE THAN 10 FEET BEYOND THE CENTERLINE OF THE BURNERS AT ANY TIME
DURING TEST.
1. EXTERIOR TYPE: TREATED MATERIALS SHALL COMPLY WITH REQUIREMENTS NOTED ABOVE FOR FIRE-RETARDANT-
TREATED LUMBER AND PLYWOOD BY PRESSURE PROCESS AFTER BEING SUBJECTED TO ACCELERATED WEATHERING
ACCORDING TO ASTM D2898, USE FOR EXTERIOR LOCATIONS AND ELSEWHERE IF INDICATED.
2. INTERIOR TYPE: MOISTURE CONTENT OF 28% OR LESS WHEN TESTED ACCORDING TO ASTM D3201 AT 92% RELATIVE
HUMIDITY. USE WHERE EXTERIOR TYPE IS NOT INDICATED.
G. INSTALLATION:
1. SET CARPENTRY TO REQUIRED LEVELS AND LINES, WITH MEMBERS PLUMB, TRUE TO LINE, CUT, AND FITTED. FIT
CARPENTRY ACCURATELY TO OTHER CONSTRUCTION.
2. ATTACH SILL SEALER GASKET TO BASE FRAMING MEMBERS IN ACCORDANCE WITH MANUFACTURER'S DETAILS.
3. INSTALL PLYWOOD BACKING PANELS BY FASTENING TO STUDS; COORDINATE LOCATIONS WITH UTILITIES REQUIRING
BACKING PANELS.
4. PROVIDE BLOCKING AND FRAMING AS REQUIRED TO SUPPORT FACING MATERIALS, FIXTURES, SPECIALTY ITEMS, AND
TRIM.
A. PROVIDE METAL CLIPS FOR FASTENING GYPSUM BOARD OR LATH AT CORNERS AND INTERSECTIONS WHERE
FRAMING OR BLOCKING DOES NOT PROVIDE A SURFACE FOR FASTENING EDGES OF PANELS. SPACE CLIPS NOT
MORE THAN 16 INCHES O.C.
5. FURRING:
A. FURRING TO RECEIVE PLYWOOD PANELING: INSTALL 1 BY 3 INCH NOMINAL SIZE FURRING HORIZONTALLY AND
VERTICALLY AT 24 INCHES O.C.
B. FURRING TO RECEIVE GYPSUM BOARD: INSTALL 1 BY 2 INCH NOMINAL SIZE FURRING VERTICALLY AT 16 INCHES
O.C.
H. PROTECT MISCELLANEOUS ROUGH CARPENTRY FROM WEATHER. IF ROUGH CARPENTRY BECOMES WET, SPRAY-APPLY EPA
REGISTERED BORATE TREATMENT.
I CLEANING:
1. DISPOSE OF ALL WASTE INCLUDING SCRAP WOOD, SHAVINGS, SAWDUST, ETC., IN ACCORDANCE WITH LOCAL
REGULATIONS.
SECTION 062000 FINISH CARPENTRY
A. SEE ARCHITECTURAL DRAWINGS FOR EXTENT OF WORK.
B. ADMINISTRATIVE REQUIREMENTS:
1. COORDINATE WORK WITH PLUMBING AND ELECTRICAL ROUGH-IN, AND INSTALLATION OF ASSOCIATED COMPONENTS.
C. SUBMIT THE FOLLOWING:
1. SHOP DRAWINGS: INDICATE MATERIALS, COMPONENT PROFILES, FASTENING METHODS, JOINTING DETAILS, DIMENSIONS,
AND ACCESSORIES.
2. SAMPLES: SUBMIT 1 SAMPLE OF EACH TYPE OF EXTERIOR AND INTERIOR WOOD TRIM, MINIMUM 8 INCH LONG, INDICATING
STAIN OR COLOR, PROFILE AND FINISH.
a.
b.
c.
d.
e.
a.
a.
b.
c.
d.
D. QUALITY ASSURANCE:
1. COMPLY WITH AWI (QCP) WOODWORK ASSOCIATION STANDARDS FOR GRADES OF ARCHITECTURAL WOODWORK,
CONSTRUCTION, AND FINISHES (www.AWIQCP.ORG).
2. EXTERIOR MOCK-UP: OF WOOD TRIM, MOCK-UP MAY REMAIN PART OF FINISHED WORK.
3. INTERIOR CABINET MOCK-UP: SHOW RELATIONSHIP REMAIN OF FIND TO COUNTERTOP, MOCK-UP MAY REMAIN PART OF
FINISHED WORK.
E. STORAGE AND HANDLING:
1. PROTECT FROM SOLAR EXPOSURE AND MOISTURE DAMAGE. PROVIDE FOR AIR CIRCULATION AROUND STACKS AND
UNDER COVERINGS.
2. HANDLE MATERIALS AND PRODUCTS TO PREVENT DAMAGE TO EDGES, ENDS, OR SURFACES.
F. PROJECT CONDITIONS:
1. PROCEED WITH EXTERIOR WORK INSTALLATION ONLY WHEN FORECAST WEATHER
SPECIFIED FINISH CAN BE APPLIED WITHOUT EXPOSURE TO RAIN, SNOW, OR DAMPNESSONS PERMIT WORK TO BE
PERFORMED AND AT LEAST ONE COAT OF
2. DO NOT INSTALL INTERIOR MATERIALS UNTIL BUILDING IS ENCLOSED, WET-WORK IS COMPLETED, AND HVAC SYSTEM IS
OPERATING WITH TEMPERATURE BETWEEN 60-90 DEG F AND HUMIDITY RANGE OF 25-55%
3. DO NOT INSTALL FINISH CARPENTRY MATERIALS THAT ARE WET, MOISTURE DAMAGED, OR MOLD DAMAGED.
4. VERIFY DIMENSIONS OF OTHER CONSTRUCTION BY FIELD MEASUREMENTS BEFORE FABRICATION AND INDICATE
MEASUREMENTS ON SHOP DRAWINGS.
G. PERFORMANCE REQUIREMENTS:
1.QUALITY STANDARD: CUSTOM GRADE, PER AWIAWMAC/WI (AWS) OR AWMAC/WI (NAAWS).
2. HARDWOOD AND SOFTWOOD LUMBER: STAIN GRADE, SPECIES AS INDICATED, RIFT CUT UNLESS OTHERWISE INDICATED
3. SURFACE BURNING CHARACTERISTICS: PROVIDE MATERIALS HAVING FIRE AND SMOKE PROPERTIES AS REQUIRED BY
APPLICABLE CODE
4. COMPOSITE WOOD PRODUCTS SHALL CONTAIN NO ADDED UREA FORMALDEHYDE IN PRODUCT OR LAMINATING
ADHESIVES USED TO FABRICATE PRODUCT.
H. EXTERIOR FINISH CARPENTRY: PREPARE FOR STAIN OR PAINT FINISH WHERE INDICATED, WINDOW AND DOOR CASINGS AND
MOLDINGS, SOFFITS AND FASCIAE, AND/OR BEAMS AND WALL BRACKETS.
1. EXTERIOR SOFFITS: KILN-DRIED TONGUE AND GROOVE BOARDS, FACTORY COATED WITH EXTERIOR PRIMER
COMPATIBLE WITH TOPCOATS SPECIFIED. SPECIES, GRADE, AND PATTERN AS INDICATED.
2. LAMINATED WOOD DECKING: APPEARANCE GRADE, SMOOTH SANDED SURFACE TEXTURE IN SIMPLE SPAN LENGTHS AS
INDICATED ON DRAWINGS. PRE-FINISH WITH 1 COAT LATEX CLEAR VARNISH.
I. INTERIOR FINISH CARPENTRY:
1. DOOR AND WINDOW TRIM, BASES, MOLDS, BRACKETS, AND MISCELLANEOUS TRIM TO COMPLETE THE WORK SHALL BE
"A" GRADE, STAIN QUALITY OR PAINT GRADE AS REQUIRED, SPECIES AS SELECTED, AND FINGER JOINT AS INDICATED.
2. STAIRS, BALUSTRADES, AND HANDRAILS: SELECT AND BETTER WHITE OAK: PREPARE FOR STAINED FINISH, UNLESS
OTHERWISE INDICATED.
3. CABINET STOCK SHALL BE SELECT AND BETTER STAIN GRADE RIFT CUT WHITE OAK STOCK, UNLESS OTHERWISE
INDICATED.
A. MAGNETIC CATCH HARDWARE.
B. ADJUSTABLE SHELVING WITH PEG AND HOLE.
C. DRAWERS WITH FULL EXTENSION SOFT CLOSE GLIDES.
D. DRAWER PULLS: AS SELECTED.
E. BASIS OF DESIGN: BLUM SOFT CLOSE HINGES AND GLIDES
4. CLOSET BULKHEADS TO BE 16 INCHES DEEP. HANGING RODS TO BE SINGLE PIECE STAINLESS STEEL RODS CUT TO
LENGTH (RETRACTABLE RODS ARE UNACCEPTABLE STAIRS)
5. PULL DOWN ATTIC STAIRS: ALUMINUM STAIR CONSTRUCTION.
J. FASTENINGS:
1. EXTERIOR APPLICATIONS: STAINLESS STEEL, LENGTH REQUIRED TO PENETRATE WOOD SUBSTRATE MINIMUM 1-1/2
INCHES.
2. INTERIOR APPLICATIONS: NAILS, SCREWS, AND OTHER ANCHORING DEVICES OF TYPE, SIZE, MATERIAL, AND FINISH
REQUIRED TO PROVIDE SECURE ATTACHMENT, CONCEALED WHERE POSSIBLE.
3. MULTIPURPOSE CONSTRUCTION ADHESIVE: FORMULATION, COMPLYING WITH ASTM D3498, RECOMMENDED FOR
INDICATED USE BY ADHESIVE MANUFACTURER
4. CONCEALED JOINT FASTENERS: THREADED STEEL.
K. SHOP FINISHING:
1. SAND WORK SMOOTH AND SET EXPOSED NAILS AND SCREWS.
2. FOR OPAQUE FINISHES, APPLY WOOD FILLER IN EXPOSED NAIL AND SCREW INDENTATIONS AND SAND SMOOTH.
3. ON ITEMS TO RECEIVE TRANSPARENT FINISHES, USE WOOD FILLER MATCHING OR BLENDING WITH SURROUNDING
SURFACES AND OF TYPES RECOMMENDED FOR APPLIED FINISHES
L. EXAMINATION AND PREPARATION:
1. VERIFY ADEQUACY OF BACKING AND SUPPORT FRAMING
2. VERIFY LOCATION AND SIZES OF UTILITY ROUGH-IN ASSOCIATED WITH WORK OF THIS SECTION.
3. PRIME LUMBER AND TRIM TO BE PAINTED, INCLUDING BOTH FACES AND EDGES, UNLESS FACTORY PRIMED.
4. CONDITION INTERIOR MATERIALS TO AVERAGE PREVAILING HUMIDITY IN INSTALLATION AREAS FOR AT LEAST 24 HOURS.
M. INSTALLATION:
1. DO NOT USE MATERIALS THAT ARE UNSOUND, WARPED, IMPROPERLY TREATED OR FINISHED, INADEQUATELY
SEASONED, OR TOO SMALL TO FABRICATE WITH PROPER JOINTING A
2. INSTALL FINISH CARPENTRY LEVEL PLUMB, TRUE, AND ALIGNED WITH ADJACENT MATERIALS.
A. USE CONCEALED SHIMS WHERE NECESSARY, AND CONCEALED FASTENERS WHERE POSSIBLE. SECURE TO
SUBSTRATE USING APPROPRIATE ANCHORAGES
B. CAREFULLY SCRIBE AND CUT FINISH CARPENTRY TO FIT ADJOINING WORK.
C. REFINISH AND SEAL CUTS AS RECOMMENDED BY MANUFACTURER.
D. INSTALL TO TOLERANCE OF 1/8 INCH IN 96 INCHES FOR LEVEL AND PLUMB. INSTALL ADJOINING EXTERIOR FINISH
CARPENTRY WITH 1/32-INCH MAXIMUM OFFSET FOR FLUSH INSTALLATION AND 1/16-INCH MAXIMUM OFFSET FOR
REVEAL INSTALLATION.
3. FIT EXTERIOR JOINTS TO EXCLUDE WATER.
4. ADJUST JOINERY FOR UNIFORM APPEARANCE. ADJUST MOVING OR OPERATING PARTS TO FUNCTION SMOOTHLY.
N. CLEANING:
1. CLEAN ALL FINISH CARPENTRY ON EXPOSED AND SEMI-EXPOSED SURFACES.
2. TOUCH UP FACTORY-APPLIED FINISHES TO RESTORE DAMAGED OR SOILED AREAS.
O. PROTECTION:
1. PROTECT FROM DAMAGE WEATHER OTHER CAUSES
2 REMOVE AND REPLACE FINISH CARPENTRY MATERIALS THAT ARE WET, MOISTURE DAMAGED, OR MOLD DAMAGED.
Section 07 27 26 – Sheet Air Barriers
Part 1 – General
1.1 Summary
Provide a mechanically fastened, sheet-applied air and water-resistive barrier system on exterior walls behind cladding, including
flashing and accessories as required for a continuous, weather-tight enclosure.
1.2 Submittals
Product data for Tyvek® membrane, tape, and accessories
Installation instructions
Air and water resistance testing per ASTM standards
Material safety data sheets (MSDS)
Part 2 – Products
2.1 Manufacturer
Basis of Design: DuPont™ Tyvek® [HomeWrap® for residential or CommercialWrap® for commercial/light commercial]
Substitutions must be pre-approved and meet or exceed specified performance criteria
2.2 Materials
Air Barrier Membrane:
Spunbonded polyethylene sheet, mechanically fastened
Perm rating: > 10 perms (vapor-permeable)
Air permeance: ≤ 0.004 cfm/ft² @ 1.57 psf (ASTM E2178)
Water resistance: Pass ASTM D779
UV resistance: Up to 120 days exposure (HomeWrap); 270 days (CommercialWrap)
Fasteners:
Cap nails or staples with minimum 1" plastic cap
Flashing & Accessories:
DuPont™ Tyvek® Tape
DuPont™ FlexWrap™ for sills and curved penetrations
DuPont™ StraightFlash™ for windows and doors
DuPont™ Wrap Cap Fasteners or equivalent
Part 3 – Execution
3.1 Surface Preparation
Ensure substrate is smooth, clean, dry, and free of sharp edges
Repair surface defects before application
3.2 Installation
Install Tyvek® membrane horizontally with upper courses lapped over lower by a minimum of 6"
Vertical seams lapped minimum 6" and staggered
Secure with cap fasteners spaced per manufacturer’s instructions
Tape all seams with Tyvek® Tape
Flash all windows, doors, and penetrations with DuPont™ flashing products
Integrate properly with other building envelope materials for continuous air barrier
3.3 Field Quality Control
Visually inspect for tears, gaps, and unsealed seams
Repair and tape any punctures or incomplete laps immediately
No. Description Date
06/18/2025
Scale
Date
G.3
SPECIFICATIONS
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
a.
b.
c.
SECTION 07 21 00 — THERMAL INSULATION
PART 1 — GENERAL
1.1 SUMMARY
A. Provide all labor, materials, and equipment necessary to furnish and install thermal insulation in accordance with applicable building
codes and as shown on drawings.
B. Work includes:
1. Insulation at exterior framed walls
2. Insulation at roof/attic assemblies (MILO Insulation basis of design)
3. Insulation at floors over unconditioned space
4. Insulation at foundation walls and rim joists
5. Air sealing where applicable
1.2 REFERENCES
A. 2021 International Energy Conservation Code (IECC) or local energy code
B. ASTM C665 – Mineral-Fiber Blanket Thermal Insulation
C. ASTM C518 – Thermal Conductivity
D. ASTM E84 – Surface Burning Characteristics
1.3 SUBMITTALS
A. Product data for each insulation type, including R-values
B. Certification of compliance with local energy code
C. MSDS for spray foam or MILO insulation systems
D. Manufacturer installation guidelines for MILO attic system
PART 2 — PRODUCTS
2.1 BATT INSULATION (TYPICAL WALLS)
A. Type: Unfaced fiberglass or mineral wool batts
B. Manufacturer: Owens Corning, Johns Manville, CertainTeed, or Rockwool
C. Thickness/R-Value:
1. 2x4 walls: R-13 to R-15
2. 2x6 walls: R-19 to R-21
3. As required to meet or exceed code
D. Flame spread <25, smoke developed <450 (ASTM E84)
2.2 ATTIC AND CEILING INSULATION
A. Basis of Design: MILO Attic Insulation System
B. Description: Pre-fabricated thermal insulation panels engineered for use over attic floor framing
C. Performance:
1. Integrated air sealing and high R-value performance
2. Meets or exceeds R-49
3. Low-VOC, environmentally conscious materials
D. Installation: Installed in accordance with MILO manufacturer specifications and building code
E. Alternates: Other high-performance panelized insulation systems may be submitted for review and approval if equivalent in air sealing, R-
value, and environmental profile
2.5 FLOOR INSULATION
A. Batt or rigid board insulation
B. Minimum R-19 for floors over unconditioned spaces
PART 3 — EXECUTION
3.1 INSTALLATION
A. Install all insulation per manufacturer instructions and applicable codes
B. Fit materials snugly into framing cavities; avoid compression
C. Seal gaps, joints, and penetrations prior to installation
D. Ensure MILO panels are installed per manufacturer detailing, including attic access hatches, recessed fixtures, and ventilation clearances
3.2 CLEANUP AND PROTECTION
A. Protect all installed insulation from moisture and physical damage
B. Clean up jobsite and dispose of waste insulation properly
3.3 WARRANTY
A. Provide standard manufacturer warranties for MILO and other materials
B. Contractor to provide 1-year labor warranty
Section 07 31 13 – Asphalt Shingles
Part 1 – General
1.1 Summary
Section Includes:
Asphalt fiberglass shingles.
Underlayment and ice/water shield.
Roof flashing and accessories.
Ridge and eave ventilation.
1.2 References
A. ASTM D225 – Asphalt-Saturated Organic Felt Underlayment.
B. ASTM D3462 – Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules.
C. ASTM D3161 – Wind-Resistance of Asphalt Shingles (Fan-Induced Method).
D. ASTM D7158 – Wind Resistance of Sealed Asphalt Shingles.
E. UL 790 – Standard Test Methods for Fire Tests of Roof Coverings.
F. ICC-ES AC438 – Acceptance Criteria for Asphalt Shingles.
1.3 Submittals
A. Product Data: Manufacturer’s specifications and installation instructions.
B. Samples: One full-size shingle sample showing color and granule finish.
C. Warranty: Manufacturer’s warranty and contractor workmanship warranty.
1.4 Quality Assurance
A. Installer Qualifications: Installer must have minimum 3 years experience with similar roofing projects.
B. Comply with local building code and manufacturer’s instructions.
C. Mock-Up: Provide mock-up area of minimum 100 sq. ft. if requested by Architect/Owner.
1.5 Delivery, Storage, and Handling
A. Store shingles flat, in original packaging, protected from weather.
B. Do not stack pallets more than two high.
C. Handle to prevent damage to edges or granule surfaces.
1.6 Warranty
A. Provide manufacturer’s limited lifetime warranty with minimum 25-year non-prorated period.
B. Provide 2-year installer workmanship warranty.
Part 2 – Products
2.1 Manufacturers
Acceptable Manufacturers (or approved equal):
GAF
CertainTeed
Owens Corning
2.2 Asphalt Shingles
A. Type: Laminated architectural (dimensional) fiberglass shingles.
B. Performance:
UL Class A fire rating per UL 790.
Wind rating: ASTM D3161 Class F or ASTM D7158 Class H.
C. Color: [Specify from manufacturer’s standard colors].
D. Style: Architectural shingle to simulate wood shake appearance.
2.3 Underlayment
A. Ice and Water Shield:
Self-adhering rubberized asphalt membrane.
Minimum 40 mil thickness.
Install at all eaves, valleys, and roof penetrations.
B. Felt or Synthetic Underlayment:
ASTM D226 Type I #15 felt or approved synthetic equivalent.
2.4 Accessories
A. Ridge Vents: Shingle-over type ridge vents compatible with shingle system.
B. Starter Strips: Manufacturer’s standard starter shingles.
C. Flashing:
Pre-finished aluminum or galvanized steel, minimum 26 gauge.
Include step flashing at roof-to-wall intersections and valley flashing.
D. Fasteners:
Corrosion-resistant roofing nails, 12-gauge shank, 3/8" minimum head, long enough to penetrate decking by 3/4".
Part 3 – Execution
3.1 Examination
A. Verify roof deck is dry, clean, and structurally sound.
B. Plywood or OSB decking must be properly fastened with no protruding fasteners.
3.2 Preparation
A. Remove existing roofing materials as required.
B. Replace any rotted or damaged sheathing.
C. Install drip edge at eaves and rakes before underlayment.
3.3 Installation
A. Install underlayment and ice/water shield per code and manufacturer’s guidelines.
B. Apply shingles starting at the lowest point, working upward in a staggered pattern.
C. Nail shingles in designated nailing zone with required number of fasteners.
D. Install ridge caps, flashing, vents, and accessories in accordance with shingle manufacturer.
E. Ensure proper ventilation is maintained per code (minimum 1:150 or 1:300 ratio depending on conditions).
3.4 Cleaning and Protection
A. Remove all debris, fasteners, and cuttings from roof and surrounding areas.
B. Protect completed roof from damage until final acceptance.
a.
b.
c.
a.
b.
c.
d.
e.
a.
b.
c.
d.
e.
f.
g.
h.
SECTION 08 11 13 — RESIDENTIAL DOORS
PART 1 — GENERAL
1.1 SUMMARY
A. Furnish and install all interior and exterior doors, frames, hardware, and accessories as indicated on drawings and specified
herein.
B. Interior Doors: Hollow core and solid core 6-panel doors.
C. Exterior Doors: Vinyl-clad doors by Pella or approved equal.
1.2 SUBMITTALS
A. Product data sheets for all doors, frames, and hardware.
B. Samples of door styles and finishes for Owner approval.
C. Shop drawings for custom or factory-finished doors.
PART 2 — PRODUCTS
2.1 INTERIOR DOORS
A. Hollow Core Doors:
1. Type: 6-panel molded or flush hollow core doors.
2. Core: Honeycomb or composite core.
3. Thickness: 1-3/8 inches typical.
4. Material: Primed MDF or wood veneer face.
5. Finish: Factory-primed, ready to paint.
6. Sizes: As indicated on plans or schedule.
B. Solid Core Doors:
1. Type: 6-panel wood or wood veneer solid core doors.
2. Core: Particleboard or MDF core for sound reduction.
3. Thickness: 1-3/8 inches or 1-3/4 inches per schedule.
4. Material: Painted or stained wood veneer or MDF face.
5. Finish: Factory finished or field finished per Owner’s preference.
2.2 EXTERIOR DOORS
A. Basis of Design:
1. Pella® Vinyl-Clad Exterior Doors (model series to match project scope).
2. Construction: Multi-chamber vinyl frame with reinforced core for strength.
3. Door Panel: Vinyl clad or fiberglass with insulated core.
4. Finish: Factory-applied paint or stain finish (color as selected by Owner).
5. Energy Performance: Meet or exceed local energy code requirements (e.g., ENERGY STAR® rated).
6. Hardware Prep: Factory prepped for locksets, hinges, and weather stripping.
B. Alternates:
1. Other manufacturers meeting equivalent performance and aesthetic criteria, approved by Owner and Architect.
PART 3 — ACCESSORIES
3.1 FRAMES
A. Interior door frames: Wood jambs, primed or factory finished to match doors.
B. Exterior door frames: Manufacturer’s vinyl or composite frames matching door system.
3.2 HARDWARE
A. Provide hardware as specified in Section 08 71 00 or as scheduled.
B. Hinges, locks, handles, door stops, and weatherstripping coordinated for each door type and function.
3.3 THRESHOLDS AND WEATHERSTRIPPING
A. Provide door sweeps, thresholds, and weather seals on all exterior doors to ensure proper air and water infiltration control.
PART 4 — EXECUTION
4.1 INSTALLATION
A. Install doors, frames, and hardware in accordance with manufacturer’s instructions and industry best practices.
B. Ensure doors swing freely without binding; align door panels properly in frame.
C. Adjust hardware for smooth operation.
D. Install weatherstripping and thresholds on exterior doors to prevent drafts and moisture intrusion.
4.2 FINISHING
A. Interior doors primed or factory finished per product requirements.
B. Field finish doors only when factory finish is not provided, using compatible paints or stains.
Section 08 53 13 – Vinyl Windows
Part 1 – General
1.1 Summary
Provide factory-assembled residential vinyl windows with integral nail flange and Low-E insulated glazing.
1.2 Submittals
Product data and installation instructions
Manufacturer’s warranty (limited lifetime)
NFRC performance ratings
AAMA certification documents
1.6 Warranty
Manufacturer’s limited warranty:
20 years on insulated glass seal.
10 years on frame and components.
2 years on factory-applied finish.
Part 2 – Products
2.1 Manufacturer
Basis of Design: Pella® 250 Series or Pella® Encompass by Pella® vinyl windows.
Acceptable manufacturers: Andersen, Milgard, JELD-WEN, or approved equal meeting or exceeding specified requirements.
2.2 Materials
Frame: Multi-chambered, fully welded vinyl with integral nail flange; interior/exterior color: [white/tan/almond/etc.]
Glazing: Dual-pane insulated glass with Low-E coating (Pella Advanced Low-E Insulating Glass with Argon or equivalent)
Spacer: Intercept® Low Conductance Spacer System or equivalent
Hardware: Manufacturer’s standard cam-action locks and tilt latches (if applicable)
Screens: Half or full screen with fiberglass mesh and vinyl frame, as applicable
2.3 Performance Requirements
NFRC certified; Energy Star compliant for climate zone [insert zone]
Minimum thermal performance:
U-Factor: ≤ 0.30
SHGC: ≤ 0.30
AAMA/WDMA/CSA 101/I.S.2/A440 Performance Grade: PG-30 minimum
Air infiltration ≤ 0.30 cfm/ft² @ 1.57 psf
Water penetration ≥ 3.75 psf
Structural load as required by local code
Part 3 – Execution
3.1 Installation
Install per Pella’s published instructions and ASTM E2112
Secure through integral nail flange; shim and insulate as needed
Use manufacturer-approved flashing and sealants
Coordinate with wall weather-resistive barrier and siding finish
3.2 Cleaning and Protection
Remove labels, clean glass and frames with approved cleaners
Protect installed units from damage during construction
SECTION 08 62 00 — UNIT SKYLIGHTS
PART 1 — GENERAL
1.1 SUMMARY
A. Provide and install factory-assembled skylights and tubular daylighting devices, including flashing, electric operation components, and
accessories.
B. Products include:
1. Electric venting skylights
2. Flexible sun tunnel tubular skylights (light tubes)
1.2 SUBMITTALS
A. Product data and installation instructions
B. Shop drawings or manufacturer details for custom roof integration
C. Warranty information
D. Electrical requirements and wiring diagram for electric units
1.3 QUALITY ASSURANCE
A. Manufacturer: Products shall be by VELUX®, or approved equal.
B. Installation: Performed by experienced personnel in accordance with manufacturer instructions.
PART 2 — PRODUCTS
2.1 ELECTRIC SKYLIGHT
A. Basis of Design: VELUX® "VS Series" or "VSE Series" Electric Venting Skylight
B. Type: Curb-mounted or deck-mounted, as shown on drawings
C. Size: As indicated on drawings or standard size closest to opening
D. Frame: Maintenance-free, extruded aluminum with interior wood core
E. Glazing: Laminated dual-pane Low-E3 insulated glass
F. Operation:
1. Fully electric operation with remote control
2. Integrated rain sensor for automatic closing
G. Finish: Factory-finished exterior in neutral color (typically bronze or gray)
H. Controls: Wireless remote control; solar-powered wall-mounted keypad optional
I. Accessories: Interior insect screen and factory flashing kit to match roof type
a.
b.
c.
d.
e.
a.
b.
c.
d.
e.
f.
2.2 FLEXIBLE LIGHT TUBE (SUN TUNNEL)
A. Basis of Design: VELUX® TGF/TMR Series Flexible Sun Tunnel
B. Type: Residential, roof-mounted daylighting device
C. Tube Type: Flexible reflective tunnel for attic installations with obstructions
D. Diameter: 14" standard, or as needed for room size and light level
E. Dome: Impact-resistant acrylic or polycarbonate with UV-resistant coating
F. Diffuser: Double-glazed frosted diffuser for soft indoor light
G. Accessories:
1. Light kit (if nighttime illumination is desired)
2. Optional rigid extension tube for longer runs
2.3 FLASHING
A. Provide manufacturer-approved flashing kits for all skylights and sun tunnels.
B. Coordinate with roofing material (shingle, metal, tile) to ensure weather-tight seal.
C. Use underlayment collars or weatherproofing membranes where required by local codes.
PART 3 — EXECUTION
3.1 INSTALLATION
A. Install skylights and sun tunnels in accordance with Velux installation instructions.
B. Ensure full integration with roofing underlayment and flashing systems.
C. Coordinate electric rough-in for powered skylights.
D. Secure light tube pathway with minimal bends for optimal light performance.
3.2 SEALING AND WEATHERPROOFING
A. Ensure flashing is watertight and continuous with roof underlayment.
B. Caulk or seal all penetrations as required by roofing standards and manufacturer recommendations.
3.3 CLEANING AND PROTECTION
A. Clean units of fingerprints, debris, and sealant residue after installation.
B. Protect skylight glazing and finishes from construction damage.
SECTION 08 71 00 — DOOR HARDWARE
PART 1 — GENERAL
1.1 SUMMARY
A. Provide all door hardware required for interior and exterior doors to match existing house hardware in style, finish, and function.
B. Hardware includes locks, passage sets, privacy locks, hinges, stops, and weatherstripping.
1.2 SUBMITTALS
A. Submit product data sheets and finish samples for approval prior to ordering.
B. Provide hardware schedule keyed to door numbers.
PART 2 — PRODUCTS
2.1 HARDWARE STYLE AND FINISH
A. Style:
1. Match existing house hardware style, typically traditional or transitional lever or knob designs.
2. Confirm style with Owner or Architect by reviewing existing hardware samples or photos.
B. Finish:
1. Match existing hardware finish (e.g., Satin Nickel, Oil-Rubbed Bronze, Polished Brass, Antique Brass).
2. Provide finish samples for approval.
2.2 INTERIOR DOOR HARDWARE
A. Passage Sets: For closets, hallways, and other non-locking doors.
B. Privacy Sets: For bathrooms and bedrooms, locking from inside with emergency release outside.
C. Hinges:
1. Steel or brass, matching finish of hardware.
2. Size: 3.5" standard residential.
2.3 EXTERIOR DOOR HARDWARE
A. Entry Locks:
1. Keyed deadbolt locksets with matching lever or knob.
2. Grade 2 or higher ANSI/BHMA certified.
B. Hinges:
1. Ball bearing hinges, minimum 4.5" size, finish matched to locksets.
C. Weatherstripping and Thresholds:
1. Provide durable weatherstripping to ensure proper air and water sealing.
2. Thresholds to match existing or new door system.
PART 3 — EXECUTION
3.1 INSTALLATION
A. Install hardware in strict accordance with manufacturer instructions and best practices.
B. Coordinate keying with existing house master key system if applicable.
C. Adjust all hardware for smooth, quiet operation.
D. Verify locks function properly and latches engage securely.
3.2 PROTECTION
A. Protect hardware during construction to prevent damage or finish defects.
B. Replace any damaged hardware prior to project completion.
Section 09 29 00 – Gypsum Board
Part 1 – General
1.1 Summary
Provide all gypsum board for interior partitions and ceilings, including standard, moisture-resistant, fire-rated, and acoustically enhanced
boards as indicated. Include all necessary accessories, joint treatment, and finishing.
1.2 Submittals
Product data for each board type
Manufacturer’s installation instructions
Compliance documentation with ASTM standards and applicable code requirements
Part 2 – Products
2.1 Manufacturer
Basis of Design: National Gypsum
Standard Board: Gold Bond® XP® Gypsum Board
Fire-Rated: Gold Bond® XP® Fire-Shield® Type X
Moisture-Resistant: Gold Bond® XP® Mold & Moisture Resistant
Acoustical Board: SoundBreak XP® Acoustical Gypsum Board
Acceptable equals: USG, CertainTeed, Georgia-Pacific, or approved equal meeting the same performance criteria
2.2 Materials
Standard Gypsum Board: ASTM C1396, 1/2" thick, tapered edge
Ceiling Board: 5/8" thick, sag-resistant as required
Type X Fire-Rated Board: ASTM C1396, 5/8", for rated assemblies
Moisture- and Mold-Resistant Board: ASTM C1396, with mold-inhibiting core and treated paper
Acoustical Gypsum Board – SoundBreak XP®: Laminated double-layer gypsum core with viscoelastic damping polymer 5/8" thick,
ASTM C1396 compliant
STC-rated assemblies ≥ STC 55 depending on assembly design. Use in bedrooms, bathrooms, home offices, media rooms, and
demising walls
Accessories:
Joint compound, tape, control joints, corner beads, and trims compliant with ASTM C475
Part 3 – Execution
3.1 Installation
Install all boards per ASTM C840 and manufacturer’s recommendations
Install SoundBreak XP® per National Gypsum’s acoustic wall design details
Cut cleanly and fit boards snugly; stagger end joints
Do not bridge over irregular or unstable framing
Use appropriate fasteners: screws at 12" o.c. for walls, 8" o.c. for ceilings (unless otherwise noted)
3.2 Finishing
Finish joints to Level 4 unless otherwise indicated
Use mold-resistant coatings in wet areas prior to painting or tile installation
For acoustical assemblies, seal all perimeter joints and penetrations with acoustical sealant
3.3 Protection
Protect installed materials from damage and moisture
Replace or repair damaged materials before final finishes
No. Description Date
06/18/2025
Scale
Date
G.4
SPECIFICATIONS
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
SECTION 23 00 00 — HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)
PART 1 — GENERAL
1.1 SUMMARY
A. Provide complete HVAC systems for heating, cooling, ventilation, and air distribution throughout the residence as shown on drawings
and specified herein.
B. Work includes:
1. Central heating and air conditioning unit
2. Ductwork and registers
3. Thermostats and controls
4. Refrigerant and condensate piping
5. Exhaust fans and ventilation systems
6. Fresh air intake, ERV/HRV (as applicable)
1.2 SUBMITTALS
A. Submit product data sheets for all HVAC equipment and components
B. Provide equipment performance data, including SEER, EER, AFUE, and HSPF ratings
C. Submit HVAC layout or shop drawing if required
D. Submit warranty documentation
1.3 QUALITY ASSURANCE
A. Equipment and installation shall comply with all applicable building, energy, and mechanical codes (e.g., IRC, IECC, and local codes)
B. Installation by licensed HVAC contractor
C. Test and balance system for airflow and temperature performance
PART 2 — PRODUCTS
2.1 HVAC SYSTEM TYPE (BASIS OF DESIGN)
A. System Type: Split-system forced-air central HVAC
1. Gas furnace with electric A/C
2. OR all-electric heat pump (climate dependent)
3. Optional zoning if residence has more than one floor or wing
B. Furnace (if applicable):
1. AFUE: Minimum 95% efficiency
2. Two-stage or variable-speed preferred
3. ECM blower motor
C. Air Conditioner / Heat Pump:
1. SEER2 Rating: Minimum 16
2. HSPF2 (heat pump): Minimum 10
3. Variable or two-stage compressor preferred
4. Condenser with sound rating <76 dB(A)
D. Thermostats:
1. Programmable or Wi-Fi-enabled smart thermostats
2. One per zone
2.2 DUCTWORK
A. Galvanized sheet metal or ductboard per local code
B. Flex duct allowed for short branch runs only
C. Insulate to minimum R-8 for attic runs, R-6 for interior spaces
D. Provide balancing dampers and fire/smoke dampers as required
E. Provide Aprilaire filter box
2.3 REGISTERS AND GRILLES
A. Supply and return grilles sized for airflow and noise control
B. Finish: White or as selected by Owner
C. Ceiling, wall, or floor-mounted as appropriate
2.4 FRESH AIR VENTILATION
A. Provide fresh air intake in compliance with IRC and ASHRAE 62.2
B. Energy Recovery Ventilator (ERV) or Heat Recovery Ventilator (HRV) where required
C. Bathroom exhaust fans rated at minimum 50 CFM, continuous or switched
2.5 CONDENSATE AND REFRIGERANT PIPING
A. Copper refrigerant lines sized per manufacturer
B. Condensate drains with trap, cleanout, and overflow shutoff switch
C. Insulate suction line with closed-cell foam insulation
PART 3 — EXECUTION
3.1 INSTALLATION
A. Install equipment and ductwork per manufacturer recommendations and applicable codes
B. Coordinate with electrical and structural trades for power supply and clearances
C. Provide vibration isolation and seismic support as required
3.2 STARTUP AND TESTING
A. Start all equipment, check refrigerant charge, and verify performance
B. Balance airflow to each room per design
C. Test thermostat functions and program settings
3.3 COMMISSIONING
A. Provide Owner with system demonstration and user instructions
B. Submit final air balancing report (if required)
C. Provide written warranty and maintenance documentation
3.4 WARRANTY
A. Manufacturer warranty: 10-year parts minimum
B. Contractor labor warranty: 1 year minimum
SECTION 09 30 00 — TILE INSTALLATION
PART 1 — GENERAL
1.1 SUMMARY
A. Furnish and install tile and associated waterproofing and uncoupling membrane systems in all bathroom floor and shower areas.
B. Work includes:
1. Schluter®-Shower System for tiled shower assembly
2. Schluter®-DITRA underlayment for tile installation over wood subfloor outside of shower
1.2 SUBMITTALS
A. Product data for all Schluter® materials
B. Manufacturer’s installation instructions
C. Warranty documentation
1.3 QUALITY ASSURANCE
A. Tile and waterproofing installation shall conform to current TCNA Handbook methods and ANSI standards.
B. Installers shall be trained and experienced in Schluter® product installation or certified by the manufacturer.
PART 2 — PRODUCTS
2.1 MANUFACTURER
A. Schluter®-Systems L.P. — www.schluter.com
2.2 SHOWER SYSTEM COMPONENTS (WET AREA)
A. Waterproofing Membrane:
1. Schluter®-KERDI — polyethylene waterproofing membrane with non-woven fleece.
2. Applied with unmodified thin-set mortar.
B. Shower Tray:
1. Schluter®-KERDI-SHOWER-T/-TS/-TT — pre-sloped EPS shower tray
2. Sized to suit field conditions; may be trimmed.
C. Shower Curb:
1. Schluter®-KERDI-BOARD-SC — EPS curb with cementitious coating.
D. Drain:
1. Schluter®-KERDI-DRAIN or KERDI-LINE
2. Grate finish: [Specify, e.g., Brushed Stainless]
E. Accessories:
1. Schluter®-KERDI-BAND, inside/outside corners, pipe/valve seals
2.3 FLOOR TILE UNDERLAYMENT (DRY AREA)
A. Uncoupling Membrane Over Wood Subfloor:
1. Schluter®-DITRA
2. Polyethylene membrane with square dovetailed recesses and anchoring fleece
3. Functions: uncoupling, waterproofing (optional), vapor management, load distribution
B. Substrate Requirements:
1. APA-rated tongue-and-groove plywood or OSB subfloor, min. 19/32"
2. Floor shall be clean, dry, and flat before installation
PART 3 — EXECUTION
3.1 PREPARATION
A. Verify that substrates are structurally sound and properly fastened
B. Fill joints and level irregularities as required
C. Coordinate waterproofing membrane transitions between wet and dry areas
3.2 INSTALLATION — SHOWER SYSTEM
A. Install KERDI membrane on walls and floor with unmodified thin-set mortar
B. Ensure 2" minimum overlap at seams
C. Install tray, drain, curb, and accessories in accordance with Schluter® instructions
D. Flood test pan prior to tiling as required by code
3.3 INSTALLATION — FLOOR TILE OVER DITRA
A. Install DITRA membrane with modified thin-set mortar over wood subfloor
B. Ensure full contact between fleece backing and subfloor
C. Allow proper cure time before applying tile
D. Set tile with unmodified thin-set mortar over DITRA surface
3.4 TILE INSTALLATION
A. Install tile as per ANSI A108 and TCNA guidelines
B. Maintain uniform grout joint width; use spacers as needed
C. Use appropriate grout and sealant per manufacturer and project requirements
3.5 PROTECTION
A. Protect completed tile surfaces from damage until final acceptance
B. Prevent heavy traffic until mortar and grout have fully cured
3.6 WARRANTY
A. Provide manufacturer’s system warranty (Schluter®) when installed as a complete system
B. Coverage: lifetime limited warranty using full Schluter® components
SECTION 09 60 00 — FLOORING
PART 1 — GENERAL
1.1 SUMMARY
A. Provide all labor, materials, and equipment necessary to complete installation of laminate wood plank flooring over prepared subfloor.
B. Work includes:
1. Flooring underlayment (if separate)
2. Laminate plank flooring
3. Transition strips and edge profiles
4. Trim coordination at baseboards and doorways
1.2 BASIS OF DESIGN
A. Basis of Design Product:
1. Pergo® Outlast+ (or comparable)
a. Dimensions: 10mm thickness (includes attached underlayment)
b. Wear Rating: AC4 or higher
c. Waterproof surface with SpillProtect™
d. Finish: Low-gloss wood grain texture
e. Installation: Floating, click-lock system
B. Approved Alternates (upon Owner approval):
1. Mohawk® RevWood Plus
2. Shaw® Repel Laminate
3. Quick-Step® NatureTEK Select
4. PPG Kronotex® Mammut
C. All alternate products must meet or exceed performance and visual characteristics of basis-of-design product.
1.3 ALLOWANCE
A. Material Allowance: $4.00 per square foot (excluding labor)
B. Applies to flooring only. Underlayment, accessories, and installation are excluded from this allowance.
C. Any selections above the allowance shall be paid by the Owner as an upgrade via change order.
D. Owner to make final selection from approved options prior to procurement.
1.4 SUBMITTALS
A. Product data sheets for proposed flooring
B. Samples of proposed flooring for Owner approval
C. Manufacturer’s installation instructions and warranty documents
PART 2 — PRODUCTS
2.1 LAMINATE FLOORING
A. Laminate wood flooring planks, 7–10mm thick, AC3 minimum (AC4 preferred), textured woodgrain surface, click-lock installation
B. Color/finish: To be selected by Owner from approved line
C. Surface: Water-resistant or waterproof preferred for kitchens, baths, laundry rooms
2.2 ACCESSORIES
A. Underlayment (if separate from plank): Manufacturer-approved foam or cork underlayment
B. Edge transitions, reducers, and threshold trims to match or complement flooring
C. Moisture barrier if required over concrete slabs or below-grade areas
PART 3 — EXECUTION
3.1 PREPARATION
A. Verify that subfloor is clean, level, dry, and suitable for installation
B. Perform moisture tests where applicable (concrete slabs)
C. Remove or undercut door casing and trim as required for a clean installation
3.2 INSTALLATION
A. Install per manufacturer’s instructions and industry standards
B. Maintain required expansion gaps at walls and fixed objects
C. Lay planks in straight, aligned rows with staggered joints
D. Do not install flooring in areas subject to standing water unless approved by manufacturer
3.3 CLEANING AND PROTECTION
A. Clean completed floors of dust, glue residue, and construction debris
B. Protect finished flooring from damage until Owner occupancy
C. Do not allow heavy traffic or rolling loads until installation is complete and accepted
SECTION 09 68 00 — CARPETING
PART 1 — GENERAL
1.1 SUMMARY
A. Provide all labor, materials, and equipment necessary to complete the installation of carpet and cushion (pad) in designated residential
areas.
B. Work includes:
1. Broadloom carpet
2. Carpet cushion (pad)
3. Seam adhesives, transitions, and edge treatments
4. Substrate preparation and final cleaning
1.2 BASIS OF DESIGN
A. Carpet:
1. Manufacturer: Shaw Floors®
2. Product: Shaw “Foundations" series or equivalent
3. Fiber: 100% continuous filament nylon or polyester
4. Style: Cut pile or textured, residential grade
5. Weight: 40–60 oz./sq. yd.
6. Construction: Tufted broadloom, stain-resistant
7. Color: Selected by Owner
B. Approved Carpet Alternates (with Owner approval):
1. Mohawk® SmartStrand® or EverStrand®
2. Dream Weaver® Residential Collection
3. Phenix® Residential Carpet
C. Carpet Pad (Cushion):
1. Basis of Design: Leggett & Platt® 7/16" Rebond Pad, 8 lb. density
2. Minimum Standard: 7/16" thickness, 6–8 lb. density
3. Low-VOC and CRI Green Label Certified
4. Moisture barrier or antimicrobial treatment optional based on room use
1.3 ALLOWANCE
A. Material Allowance:
1. $4.00 per square foot total, applied to carpet and pad combined
2. Does not include labor, installation materials, or accessories
3. Any selection exceeding this allowance shall be paid by Owner as an upgrade via change order
B. Owner shall make final selection from approved samples within the allowance.
1.4 SUBMITTALS
A. Product data and technical specifications for carpet and pad
B. Samples of carpet and cushion for Owner approval
C. Manufacturer’s installation guidelines and warranty
1.5 QUALITY ASSURANCE
A. Installer shall be certified or regularly engaged in residential carpet installation
B. Installation shall comply with Carpet and Rug Institute (CRI 104/105) guidelines
1.6 WARRANTY
A. Provide manufacturer’s standard residential warranty
1. Minimum: 10-year wear and stain warranty for carpet
2. Minimum: 10-year warranty for pad
PART 2 — PRODUCTS
2.1 CARPET
A. Residential broadloom carpet, 12-foot wide
B. Construction: Tufted, cut pile or textured loop
C. Primary backing: Woven synthetic
D. Secondary backing: ActionBac® or similar
E. CRI Green Label Plus Certified
2.2 CARPET PAD (CUSHION)
A. High-density rebond polyurethane foam pad
B. Thickness: 7/16" (±1/16")
C. Density: Minimum 6 lb./cu. ft.; 8 lb. preferred
D. Optional: Spill barrier film or antimicrobial treatment for basements, playrooms, or pet areas
2.3 ACCESSORIES
A. Tack strip, transition strips, reducers, adhesives as needed for a complete installation
B. Edge guards or carpet-to-hard surface transitions where required
PART 3 — EXECUTION
3.1 PREPARATION
A. Verify subfloor is clean, dry, and level
B. Remove debris, protrusions, and old adhesives
C. Perform moisture tests in below-grade areas
3.2 INSTALLATION
A. Install carpet and pad per CRI and manufacturer guidelines
B. Stretch-in method with tack strip unless otherwise specified
C. Seams to be minimized and located away from traffic paths
D. Ensure tight edge transitions at tile, wood, or LVP interfaces
3.3 CLEANING AND PROTECTION
A. Vacuum newly installed carpet and remove debris
B. Protect from soiling and traffic until final acceptance
C. Provide leftover material for future patching
Section 09 80 00 – Acoustical Treatment
Part 1 – General
1.1 Summary
Provide mineral wool insulation for interior partitions, floor-ceiling assemblies, and other locations to reduce airborne sound transmission and
improve acoustic privacy.
1.2 Submittals
Product data for acoustical insulation
Manufacturer’s installation guidelines
Acoustic performance data (STC ratings of assemblies)
Part 2 – Products
2.1 Manufacturer
Basis of Design: Rockwool Safe’n’Sound® by Rockwool North America
Substitutions must meet or exceed all listed performance and physical characteristics and be approved in writing.
2.2 Materials
Type: Semi-rigid mineral wool batts, friction-fit
Dimensions: 16" or 24" wide x 47" long
Thickness: 3" (for 2x4 walls) or 6" (for 2x6 assemblies)
Density: Nominal 2.5 lbs/ft³
STC Performance: Improves sound transmission class (STC) ratings of standard wall and floor assemblies by up to 10–15 points depending
on design
Fire Resistance: Non-combustible per ASTM E136; melting point > 2150°F (1177°C)
Moisture Resistance: Water-repellent; will not promote mold, mildew, or bacterial growth
Sustainability: GREENGUARD Gold certified; no added formaldehyde
Part 3 – Execution
3.1 Installation
Install per manufacturer’s instructions and best practices for acoustical assemblies
Fit batts snugly into framing cavities without gaps, voids, or compression
Trim around electrical boxes, plumbing, and obstructions
Do not compress or stack insulation behind drywall or sheathing
Coordinate with other trades to ensure full cavity fill before enclosure
3.2 Coordination
Ensure placement of resilient channels, double-stud construction, or other acoustic detailing is completed per acoustic consultant or design
intent Coordinate installation with gypsum board and sealant trades for full acoustical performance
No. Description Date
06/18/2025
Scale
Date
G.5
SPECIFICATIONS
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
SECTION 26 00 00 — ELECTRICAL
PART 1 — GENERAL
1.1 SUMMARY
A. Provide all labor, materials, equipment, and services necessary to complete the electrical work for the residence as shown on
drawings and as specified herein.
B. Work includes:
1. Electrical service and distribution
2. Receptacles, switches, and lighting fixtures
3. Wiring and conduit
4. Grounding and bonding
5. Smoke and carbon monoxide detectors
6. Low voltage raceways (data, security, TV, etc.)
7. Panelboards and circuit breakers
1.2 CODES AND STANDARDS
A. All electrical work shall comply with the National Electrical Code (NEC, NFPA 70), local amendments, utility provider requirements,
and applicable state/local building codes.
1.3 SUBMITTALS
A. Product data for panelboards, devices, lighting, and other equipment
B. Shop drawings if custom electrical panel layout is required
C. Manufacturer documentation for lighting controls and specialty systems
PART 2 — PRODUCTS
2.1 ELECTRICAL SERVICE AND DISTRIBUTION
A. Service Size: As shown on electrical drawings (typically 200A or 400A residential)
B. Panelboards:
1. NEMA 1 indoor, load centers with copper bus
2. Main breaker and branch circuit breakers
3. Allow space for future circuits
C. Subpanels: As needed for detached structures or large residences
D. Circuit breakers: Thermal-magnetic; AFCI/GFCI as required by code
2.2 WIRING AND CONDUIT
A. Residential branch circuit wiring: Type NM-B (Romex), copper conductors, minimum #12 AWG
B. Wet locations: Use THWN-2 in PVC conduit
C. Grounding conductors per NEC and local code
D. Provide arc fault and ground fault protection where required
2.3 RECEPTACLES AND SWITCHES
A. Devices: Residential grade, tamper-resistant
B. Color: White (or as selected by Owner)
C. Mounting Height:
1. Switches: 48" AFF
2. Receptacles: 16" AFF standard, 48" in garage
D. GFCI Protection:
1. All outlets in bathrooms, kitchens, garages, unfinished basements, and outdoors
2. Weather-resistant covers at exterior outlets
2.4 LIGHTING
A. Fixtures: Energy-efficient LED fixtures unless otherwise noted
B. Interior Lighting:
1. Recessed cans, surface-mount ceiling fixtures, undercabinet lights (where shown)
2. Dimmable where specified
C. Exterior Lighting:
1. Porch, garage, and pathway lights
2. Fixtures rated for wet/damp locations
D. Controls:
1. Manual switches and dimmers
2. Motion sensors or photocells at exterior (as specified)
2.5 DETECTION AND SAFETY DEVICES
A. Smoke detectors: 120V with battery backup, interconnected per code
B. Carbon monoxide detectors: Where required by code, near bedrooms and gas appliances
C. Doorbell: Wireless or hardwired system with chime
2.6 SPECIALTY SYSTEMS
A. Low Voltage Raceways: Provide boxes and conduit for rough-in only (CAT6, coax, speaker wire)
B. EV Charger: Provide dedicated 240V circuit with NEMA 14-50R or hardwired EVSE if shown
C. Generator Transfer Switch: Pre-wired or manual transfer switch if specified
PART 3 — EXECUTION
3.1 INSTALLATION
A. Install all equipment per NEC, manufacturer instructions, and local code
B. Coordinate exact locations of outlets, switches, and fixtures with Owner and Architect
C. Support boxes securely; use appropriate box types for each location
3.2 LABELING AND IDENTIFICATION
A. Label all panelboards and circuits clearly and permanently
B. Provide typed circuit directory at each panel
3.3 TESTING AND FINALIZATION
A. Test all systems for continuity, ground, and proper function
B. Adjust dimmers and smart controls as needed
C. Provide Owner orientation on electrical panel and controls
3.4 WARRANTY
A. Provide 1-year contractor warranty on labor and workmanship
B. Equipment warranties per manufacturer
No. Description Date
06/18/2025
CP #51
3/8"IR
MISC 3" PVC DISC SENTRICON
MISC POWER CONTROL CONSOLE
FF EL=604.11'
concrete
concrete
concrete
rock walkway
gravelwood retaining wall
rock retaining wall
wood retaining wall
wood retaining wall
wood retaining wall
wood retaining wall
House
wo
o
d
b
o
a
r
d
f
e
n
c
e
wo
o
d
b
o
a
r
d
f
e
n
c
e
wood board fence
12,500 square feet
(0.2870 acres)
John M. and wife Christa
C. Sladden
Volume 9145, Page 467
D.R.T.C.T.
Lot 24, Block 3
Western Oaks
Volume 388-204, Page 91
P.R.T.C.T.
N0
0
°
3
8
'
0
9
"
E
1
4
8
.
2
5
'
S89°21'51"E 84.32'
S0
0
°
3
8
'
0
9
"
W
1
4
8
.
2
5
'
N89°21'47"W 84.32'
Lot 25, Block 3
Western Oaks
Volume 388-204, Page 91
P.R.T.C.T.
Lot 23, Block 3
Western Oaks
Volume 388-204, Page 91
P.R.T.C.T.
Lot 22, Block 3
Western Oaks
Volume 388-204, Page 91
P.R.T.C.T.
Lot 21, Block 3
Western Oaks
Volume 388-204, Page 91
P.R.T.C.T.
S89°21'47"E 84.31'
N0
1
°
2
5
'
0
7
"
W
5
0
.
0
3
'
40' building line
10'x10' T.P. & L. Easement
Volume 388-204, Page 91
P.R.T.C.T.
10' Utility Easement
Volume 388-204, Page 91
P.R.T.C.T.
604
60
4
603
60
3
60
2
60
1
603.85 603.86
GR603.61
GR603.61
GR603.61
GR603.61
603.95
GR604.11
604.11
603.96
604.09 604.11
604.09 604.11
603.50
CAUTION:
UNDERGROUND ELECTRIC
TO BE RELOCATED. CONTACT LOCAL
UTILITY PROVIDER
CAUTION:
UNDERGROUND ELECTRIC
TO BE RELOCATED. CONTACT
LOCAL UTILITY PROVIDER
EXISTING RESIDENCE
2803 HIGHCREST DRIVE
F.F. = 604.11
EXISTING RESIDENCE
ADDITION
2803 HIGHCREST DRIVE
F.F. = 604.11
EXISTING TREES LOCATED IN ADDITION
AND PATIO TO BE REMOVED AS DIRECTED
BY OWNER ( HAUL OFF DEBRIS)
REMOVE EXISTING ROCK
ROCK WALKWAY AS NEEDED TO
CONSTRUCT NEW ADDITION
OR DIRECTED BY OWNER
AC UNITS
REMOVE EXISTING ROCK
GRAVEL AS NEEDED TO
CONSTRUCT NEW ADDITION
OR DIRECTED BY OWNER
HIGHCREST DRIVE
Know what's below.before you dig.Call
R
@least 48 hours prior
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
X
LEGEND
NOTES
DRAINAGE NOTESMINIMUM CLEARANCE
PER SECTION
R404.1.6 AND
R317.1 TYP
12" MINIMUM DEPTH
OR GREATER FOR
FROST PROTECTION
R403.1.4 AND
R403.1.4.1 TYP
3.5" MINIMUM
CONCRETE SLAB
PER SECTION R506.1
W
MONOLITHIC SLAB-ON-GROUND
WITH TURNED-DOWN FOOTING
NOT TO SCALE
BOTTOM (SOLE) PLATE
ATTACHED PER SECTION
R403.1.6
NOTES
EXH-1
THE SEAL APPEARING ON THIS
DOCUMENT WAS AUTHORIZED BY
TRAVIS N. ATTANASIO, P.E., CFM
ON JUNE 18, 2025
GR
A
P
E
V
I
N
E
,
T
X
GENERAL STRUCTURAL NOTES
1.0 Applicable Design Codes and Loads
1.1 Codes and standards: 2021 International Residential Code (IRC), latest edition.
1.2 Design Loads
1 LL DL
Roof (Rafters)16 psf
2 10 psf 3
Ceiling joists
Limited storage 20 psf 10 psf
No storage 10 psf 5 psf
Floors 40 psf 10 psf 4,5
Balconies 60 psf 10 psf 4,5
1.3 Wind Speed (3 sec gust) Per Plan
1.4 Ground Snow Load
6 5 psf
1.5 Seismic Design Category B
1.6 Special Loads
HVAC/Water heaters 300 lbs/unit
Exterior/Interior Walls 100 plf
Gypcrete 8.5 psf/in
Lightweight Concrete 10.5 psf/in
Normalweight Concrete 12.5 psf/in
Stone 55 psf
1.7 Deflection Limits (based on live load, except masonry)
Rafters greater than 3:12 L/180
Ceilings L/240
Floors L/360
Masonry veneer L/600
1 References: IRC Chapter 3 or IBC Chapter 16 and ASCE 7.
2 For pitches less than 4:12 use 20 psf.3 Assumes composition shingles or equivalent, unless noted otherwise. Additional load
may be required for heavier roof coverings.
4 Trusses shall have tabulated DL distributed on top chord and an additional 5 psf on
bottom chord.
5 Assumes nominal floor covering (such as wood flooring, carpet, or thinset tile),
unless noted otherwise. Additional load may be required for heavier floor coverings.
6 Snow load to be applied nonconcurrently with live load, unless noted otherwise.
2.0 General Conditions
2.1 The Engineer's basic responsibility is for member size and strength, not dimension
control or fit and finish. Special conditions or loads must be brought to the attention
of the Architect and/or Engineer.
2.2 These structural plans are based on information provided to this office. The Engineer
shall be entitled to rely on the accuracy and completeness of this information in the
preparation of the construction documents.
2.3 These plans, notes, and details are based on the minimum code requirements and
accepted local standard of care for typical single family construction practices. More
stringent installation may be required by a local jurisdiction or increased performance
expectations. All special or non-standard conditions should be brought to the
attention of the Architect and/or Engineer. Where applicable, installation shall comply
with all Texas Department of Insurance requirements.
2.4 The contractor and all subcontractors/trades are responsible for reviewing the entire
set of plans and specifications, to include dimensions and sections. Any
discrepancies must be reported to the Architect and/or Engineer prior to fabrication
or installation of structural members.
2.5 The contractor is responsible for all temporary bracing and/or supports that may be
required as the result of the contractor's construction methods or sequences.
2.6 The contractor shall comply with all applicable safety requirements.
2.7 The contractor is responsible for the timely scheduling of all required product
submittals, inspections, and any other construction documentation.
2.8 Notes, details, and schedules herein are typical and may apply to similar conditions
unless otherwise noted or shown. Not all sections, schedules or notes may apply to
each project.
2.9 Information on the structural plans may supercede general notes and details.
3.0 Materials
3.1 Wood
1. Dimensional lumber shall conform to the National Design Specification (NDS), latest
edition.
2. All lumber shall be Spruce-Pine-Fir (SPF), Southern Yellow Pine (SYP), or Douglas
Fir-Larch (DF-L), UNO. Refer to plans for grade and species of structural members.
Bracing/blocking: Utility grade
Plates:#3 grade
3. All wood framing members to have 19% or less moisture content.
4. All sills on concrete slabs shall be treated lumber.
5. All wood framing in direct contact with concrete, masonry, or exposed to weather
shall be treated lumber or otherwise protected.
6. Finger-jointed lumber may be used for studs (same grade and species), except for
balloon framing. All other finger jointed lumber shall be rated for horizontal use.
7. Dimensional lumber shall conform to the following minimum design values. Values
are for nominal 12” depth. Refer to manufacturer for conversions to alternate grades
and sizes
8. Manufactured wood products (including, but not limited to, structural wood beams
and I-joists) shall be fabricated, handled, and installed in accordance with the
manufacturer's instructions.
9. Plywood, Oriented-Strand Board (OSB), or waferboard shall comply with US
Department of Commerce Voluntary Product Standard (PS2).
10. All wood products shall be grade marked for identification.
11. Alternate materials are acceptable if they have equivalent structural capacity and
performance, as established by applicable code evaluation reports.
3.2 Steel
1. Structural steel components shall comply with the following specifications and
standards:
General: American Institute of Steel Construction (AISC)
Manual of Steel Construction
American National Design Standards: ASCE 5-13/TMS 602-13
2. Structural Steel Rolled Shapes (Wide Flange): ASTM A992
3. Structural Steel Tubes: ASTM A500 Grade B
4. Steel Pipe: ASTM A53, Grade B
5. Other Structural Steel: ASTM A36
6. High Strength Bolts: ASTM A325N
7. Anchor Bolts: ASTM A307
3.3 Connectors
1. All nails, lag screws, and bolts shall comply with NDS, Chapters 10 and 11.
2. All nails shall be common nails, UNO. Pneumatic fasteners are permitted,
provided they have the same length and shank diameter, or otherwise have
equivalent structural capacity.
3. Specified hold-downs, hangers, straps, etc. are by Simpson Strong-Tie, UNO.
Products by other manufacturers may be used, provided they have equivalent
structural capacity and have a valid ICC report. All products shall be installed per
the manufacturer's instructions.
4. All connectors exposed to weather or used in conjunction with fire-retardant
lumber shall be galvanized or otherwise protected from corrosion.
4.0 Conventional Wood Framing
4.1 Framing shall conform with the IRC or the IBC and the Wood Frame Construction
Manual (WFCM), published by the American Forest & Paper Association
(AF&PA).
4.2 Framing shall be adequate to provide a continuous load path to transfer all vertical
and lateral loads from the roof, wall, and floor systems to the foundation.
4.3 Roof-Ceiling Construction
1. Rafters shall be sized and spaced per the Rafter Span Schedule.
2. Provide purlins same size as rafters and brace with min 2x4 brace at not more
than 48 inches on center to wall, header, or elevated beam below. The slope of
struts shall not be less than 45 degrees from horizontal. Struts longer than 8' shall
be 2x4 T-brace or 2x6. At wind speeds greater than 100 mph, use 2x4 T-brace.
Struts larger than 8' shall be 2x6 T-brace.
3. Ridge straps or collar ties installed in the upper
13 of the attic space shall not be
spaced more than 48 inches on center U.N.O.
4. Hips, valleys, and ridges shall provide full end-cut bearing for supported rafters,
not less than one dimensional size larger.
5. Roof sheathing shall be minimum 7/16” thickness sheathing with 24/16 span
rating. For roof coverings weighing more than 1000 pounds per square (100
sq.ft.), roof framing spacing shall be limited to not more than 16 inches on center.
Refer to Sheathing and Cladding Attachment Schedule for fastening requirements.
6. Ceiling joists shall be sized and spaced per the Ceiling Joist Span schedule.
7. All ceilings are designed for limited attic storage unless noted otherwise, except
for cathedral type ceilings where no attic storage is permitted. Ceilings are not
designed for future rooms, unless noted otherwise.
8. Rafters and ceiling joists shall have minimum 1 1/2 inches of bearing and
opposing ceiling joists shall be lapped a minimum of 3 inches at interior bearing
walls. Rafters and joists shall be face nailed together and both shall be toe nailed
to the plate. At vaulted ceilings, cripple rafters shall be added, to achieve full
bearing and toe nailing at the plate.
9. Where ceiling joists run perpendicular to rafters or where ceiling joists do not tie
into rafters, rafter ties or some other method of resisting out thrust shall be
installed. Refer to Typical Rafter Tie Detail. Cripple joists and rafters shall be
added to allow full bearing and toe nailing at the top plate.
10.Rafter and ceiling joists with a depth:thickness ratio greater than 5:1 shall have
lateral blocking at bearing points to prevent rotation. Where solid sawn rafters and
joists are parallel and face nailed together, the combined thickness may be used.
11.Rafters and ceiling joists with a depth:thickness ratio greater than 6:1 shall have
intermediate blocking at intervals not exceeding 8 feet.
12.Notches in sawn lumber rafters and joists shall not exceed one-sixth the depth of
the member, shall not be longer than one-third the depth of the member, and shall
not be located in the middle one-third of the span. Notches at the ends shall not
exceed one-fourth the depth of the member.
13.Holes in sawn lumber rafters and joists shall not exceed one-third the depth of the
member and shall not be within 2 inches of the top or bottom edge of the member,
a notch, or another hole.
4.4 Floors
1. Floor joists shall be sized and spaced per IRC Table R502.3.1(2) or IBC Table
2308.8(2). Manufactured floor systems (such as I-joists) shall be sized and spaced
per the manufacturer's specifications. Manufactured floor trusses shall be
designed for the applicable loads.
2. Floor joists or trusses shall be doubled under parallel walls or otherwise provide
full bearing, unless noted otherwise. Joists or trusses under perpendicular walls
shall be designed for the additional loads.
3. Floor joists or trusses shall have minimum 1 1/2 inches bearing and opposing
members shall lap minimum 3 inches at interior bearing walls.
4. Floor joists or trusses shall be supported at the ends by full depth 2x blocking, full
depth beam, band or rim joist. Blocking is also required for continuous floor joists
or trusses at perpendicular load bearing walls above or below.
5. Floor joists or trusses with a depth:thickness ratio greater than 6:1 shall have
intermediate blocking or bracing at intervals not exceeding 8 feet.
6. Floor sheathing shall be minimum 23/32” thickness T&G sheathing with 48/24
span rating. Refer to Sheathing and Cladding Attachment Schedule for fastening
requirements.
7. Allowances for notches and holes in sawn lumber floor joists are the same as for
rafters and ceiling joists. For manufactured products, notches and holes are
prohibited except where permitted by the manufacturer's installation guide or
where the effects of the alterations are specifically considered in the design of the
member by a registered engineer.
4.5 Wall Construction
1. Load bearing studs shall be sized and spaced per the Wall Stud Schedules,
unless otherwise noted on the plans. Interior non-load bearing walls may be 2x4s
@ 24 inches on center up to 14' height and 2x6s @ 24 inches on center up to 20'
height.
2. Notching in any stud in a nonbearing wall shall not exceed 40 percent of its width.
Notching of any stud in an exterior or load bearing wall shall not exceed 25
percent of its width.
5.3 Field Inspections.
1. Inspections are generally conducted by qualified inspectors, representing either the
Engineer or a third party. Inspections are to verify materials installation is in substantial
conformance with the structural plans and specifications or to verify actual field
conditions as the basis for field changes or repairs. The inspection is meant to be
representative of the construction and is not meant to ensure or imply complete
compliance.
2. A copy of the inspection form will generally be left on site, reflecting the items inspected
and discrepancies noted; no other observations are to be implied or inferred. Inspections
do not relieve the contractor of the responsibility to comply with the plans, contract
documents, or other applicable requirements.
5.4 Revisions, repairs and field changes are authorized only when in writing, signed and
sealed by a professional engineer with this office. When so issued, they become
incorporated into the plans and contract documents
5.5 Special Documentation. It is the contractor's responsibility to identify any special
documentation required by a local jurisdiction or a third party. This includes any program
enrollment, including but not limited to, a homebuyer warranty program and the Texas
Department of Insurance (TDI). It is the contractor's responsibility to notify the Architect
and Engineer of these special requirements in a timely manner.
For all areas that are governed by the Texas Department of Insurance (TDI), Fastening Requirements for Wind
Borne Debris Protection shall be per Section R301.2.1.2 of Texas Revisions to the International Residential
Code (IRC) or Section 1609.1.2 of Texas Revisions to the International Building Code (IBC), Structures in the
Inland I or Seaward areas, as adopted by the Texas Department of Insurance (TDI), shall have additional
protection for wind borne debris (no additional protection is required in Inland II areas). In the Inland I area,
protection is required for glazed exterior openings. In the Seaward area, protection is required for all exterior
openings to include windows, doors, garage doors, and sky lights. All protection systems shall meet the
requirements of the large missile test in accordance with ASTM E1996 and ASTM E1886, and shall be installed
per the manufacturer's installation instructions. Removable protection systems shall have installation
instructions provided.
Alternatively, structures in the Seaward and Inland I area may be protected by 15/32" plywood panels. All
panels shall be precut and labeled for exterior application to the building framing around the opening.
Installation instructions shall be provided. Fastening shall be per TDI Revised IRC Table R301.2.1.2
(See excerpt below).
Wind Borne Debris Protection
TDI Revised IRC Table R301.2.1.2, IBC Table 1609.1.2
wind borne Debris Protection Fastening Schedule For Plywood Panels Used In The Inland I Area
Seaward
Open Areas Vented/Enclosed Areas Conditioned Areas
Inland I
Stainless steel (ASTM A167)
Hot-dip galvanized
-prior to fabrication (ASTM A653)
-after fabrication (ASTM A123/A153)
Stainless steel (ASTM A167)
Hot-dip galvanized
-prior to fabrication (ASTM A653)
-after fabrication (ASTM A123/A153)
Mechanically deposited zinc (ASTM B695)
Electrodeposited zinc (ASTM B633)
Galvanized or electrogalvanized (ASTM A641)
Any method meeting the
requirements of Open Areas
Galvanized or electrogalvanized
(ASTM A641)
Mechanically deposited zinc
(ASTM B695)
Electrodeposited zinc (ASTM B633)
Any method meeting the
requirements of Open Areas
Epoxy coating (ASTM A899)
1 2 3
Corrosion Resistance
Inland II
Stainless steel (ASTM A167)
Hot-dip galvanized
-prior to fabrication (ASTM A653)
-after fabrication (ASTM A123/A153)
Mechanically deposited zinc (ASTM B695)
Electrodeposited zinc (ASTM B633)
Galvanized or electrogalvanized (ASTM A641)
Not Required Not
Required
Not Required
Not Required
For all areas that are governed by the Texas Department of Insurance (TDI), corrosion resistance
requirements shall be per Section R325.1 of Texas Revisions to the International Residential Code (IRC) or
section 1716.1 of Texas Revisions to the International Building Code (IBC). Metal connectors and fasteners
shall be corrosion resistant in accordance with the following:
1. Fasteners shall be located a minimum of 1" from the edge of the panels.
2. Fasteners shall be long enough to penetrate through exterior sheathing and a minimum of 1 3/4" into wood
stud framing.
3. Vibration resistant anchors with a minimum withdrawal capacity of 490 lbs. shall be used when panels are
attached to masonry or masonry/stucco.
4. If plywood panels will be used in Seaward area, this office shall be contacted for fastener requirements.
Fastener SpacingFastener Type Panel span < 4 foot 4 foot < panel span < 6 foot
#6 Wood screws
#8 Wood screws
6 foot < panel span < 8 foot
16"
16"16"
12"9"
12"
For all areas not governed by the Texas Department of Insurance (TDI), wind-born debris protection shall be
provided in all areas that are within 1 mile of the coastal mean high water line where the basic wind speed is
110 mph or greater; or portions of hurricane-prone regions where the basic wind speed is 120 mph or greater.
Fastening Requirements for Wind Borne Debris Protection shall be per Table R301.2.1.2 of the IRC or Table
1609.1.2 of the IBC.
IRC Table R301.2.1.2, IBC Table 1609.1.2
Wind Borne Debris Protection Fastening Schedule For Wood Structural Panels
Fastener SpacingFastener Type
Panel span < 4 foot 4 foot < panel span < 6 foot
#8 Wood screws w/ 2"
min. embedment
6 foot < panel span < 8 foot
16"
16"12"
10"8"
9"
16"16"16"
#10 Wood screws w/
2" min. embedment
1/4"Ø lag screws w/
2" min. embedment
3. Holes in any stud in a nonbearing wall shall not exceed 60 percent of its width.
Holes in any stud in an exterior or load bearing wall shall not exceed 40 percent
of its width. Hole diameter may be increased to 60 percent of the stud width if the
studs are doubled and not more than two successive studs are so bored. Holes
may not be located within 5/8 inch of the edge of the stud or in the same section
as a notch. Approved stud shoes may also be used.
4. Load bearing walls shall have minimum one bottom plate and two top plates,
having a width at least equal to the width of the studs. The double top plate shall
overlap at corners and intersections of bearing walls. End joints and splices shall
be offset at least 24 inches, unless noted otherwise.
5. The sill plate at exterior walls shall be anchored to the foundation with anchor
bolts spaced per the Sill Plate Anchorage Schedule, with at least two bolts in
each section of sill plate spaced not more than 12" or less than 7 bolt diameters
from the end. Bolts shall be at least 1/2" diameter and shall extend at least 7
inches into the foundation. The sill plate at interior bearing walls shall be
positively connected to the foundation with approved fasteners. Additional bolts
may be required per the Sheathing Schedule or other connections. At wind
speeds in excess of 100 mph in hurricane prone regions, all anchor bolts shall
have a 2 x 2 x 14 thick plate washer or (2) 2 x 2 x 1/8 plate washers. At wind
speeds less than or equal to 100 mph, all anchors bolts shall have a standard
washer. Equivalent fasteners are permitted.
6. Single top plates may be used, except that 3” x 6” 20ga galvanized steel plates
shall be used at corners, intersections, and joints. Rafters or joists shall be
centered over studs with a tolerance of not more than 1 inch.
7. If drilling or notching of the top plate exceeds 50 percent of its width, a 1-1/2" x
16ga galvanized metal tie shall be used across the opening.
8. Headers or beams at openings shall be per IRC Table R502.5 or IBC Tables
2308.9.5 and 2308.9.6 and WFCM Table 3.23, unless otherwise noted on the
plans.
9. The ends of flush beams and girders bearing on the top plate shall be supported
by a full-height stud pack. Dropped headers shall be supported by jack studs. For
conventional lumber, stud pack or jack studs shall be not less than 1 for 2x6 and
2x8 members and not less than 2 for 2x10 and 2x12 members. For manufactured
lumber and trusses, studs shall provide full bearing and shall be not less than 1
for up to 7 1/4 depth and 2 for up to 11 7/8 depth. These are minimums -
additional studs may be required based on actual loads. At upper floors, stud
packs and jack studs with 2 or more studs shall be continued at lower floors to
the foundation, to include blocking through subfloor as necessary.
10. At dropped headers, all jack studs shall have not less than one full-height king
stud. Additional king studs may be required at exterior walls subject to wind loads.
Refer to WFCM Tables 3.23C and 3.23D. King studs may replace required jack
studs if a mechanical connector is used to fasten the header to the king stud.
11. Wall bracing shall be per the IRC Section R602.10 or IBC Section 2308.9.3.
Framing perpendicular to braced wall lines shall be blocked in the plane of the
wall as required by the IRC/IBC. Framing parallel to braced wall lines shall have a
structural member in the plane of the wall. All braced wall lines shall be anchored
to the concrete foundation. These plans may contain a layout of braced wall lines
and panels, including portions of the structure which have been designed per IRC
Section R602.10.10 or IBC Section 2308.4. Refer to the Sheathing
Schedule/Shear Connection Schedule.
4.6 Coverings, Openings and Veneers
1. Wall coverings shall comply with IRC Chapter 7. Roof coverings shall comply with
IRC Chapter 9. Coverings, windows and other openings shall be rated for the
components and cladding loads of IRC Table R301.2(2) or IBC Table
1609.6.2.1(2)
2. Windows and other openings in wind borne debris regions shall be protected per
IRC Table R301.2.1.2 or IBC Table 1609.1.2, or per the TDI as applicable
3. Masonry veneers shall not exceed 30' in height or 40psf in weight, unless noted
otherwise on the plans. Brick ties shall be minimum 22ga corrugated sheet metal,
spaced not more than 24 inches on center horizontally and supporting not more
than 2.67 square feet of masonry. In high wind areas where the basic wind speed
is greater than or equal to 110 mph but does not exceed 130 mph, space anchors
a maximum of 16"o.c. in either direction. Add additional anchors around perimeter
of opening at a maximum of 24" o.c. and place anchors within 12" of opening.
Flashing is required beneath the first course of masonry and at other points of
support. Weepholes located immediately above the flashing shall be minimum
3/16 inch diameter, spaced not more than 33 inches on center.
4. Steel lintels supporting only dead load from masonry shall be per Schedule or
plans. Lintels shall have bearing length not less than 4 inches and shall not be
fastened to the wood framing, unless noted otherwise.
5. Brick veneer not exceeding 12'-8” in height may be supported on wood framing
per IRC Section R703.7.2.
4.7 Connections
1. Connections and fasteners shall be per IRC Table R602.3 or IBC Table 2304.9.1.
2. Where joists or beams frame into a flush beam or girder, the connection shall
consist of a metal hanger or other framing angle, except that single ceiling joists
spanning not more than 6 feet may be connected with 3-8d common or
3-0.131”x3” toe nails.
3. Framing members consisting of multiple plies of dimensional lumber shall be
fastened together with 2 rows of 0.131" x 3" nails at 24 inches on center, except
where side-loaded beams shall be fastened together with 2 rows of 0.131" x 3"
nails at 12 inches on center.
4. Framing members consisting of multiple plies of engineered wood products shall
be fastened per the manufacturer's instructions. Solid members of the same
nominal size and capacity may be used in lieu of built up members.
5.0 Construction Documentation
5.1 Submittals. Review of submittals is for general conformance with the structural
drawings and project specifications, not for dimension control. The Engineer shall
be entitled to rely on the accuracy and completeness of information provided by
the contractor, the Architect, or other third party. All materials and systems shall
be installed in accordance with the structural plans, project specifications, and
manufacturer's installation instructions.
5.2 Site visits. The purpose of site visits is to observe and become generally familiar
with the quality and progress of the construction work. Site visits are not intended
as detailed inspections. The Engineer makes no warranty or guarantee about
work observed during a site visit. Site visits may be conducted by a registered
engineer or by other qualified personnel.
Bending (psi)
Compression parallel to grain (psi)
Tension parallel to grain (psi)
Horizontal shear (psi)
Compression perpendicular to grain (psi)
Modulus of Elasticity (10 psi)
Specific Gravity
SPF SYP DF-L
#2 #3 #2 #2
875
1150
450
135
425
1.4
0.42
450
725
250
175
565
1.3
0.55
750
1250
450
175
565
1.4
0.55
900
1350
575
180
625
1.6
0.50
1. Open Areas include porches, exterior coverings, roof coverings, and the underside of elevated structures.
2. Vented/Enclosed Areas include attics, exterior wall stud cavities, and crawl spaces.
3. Conditioned Areas include heated and cooled living areas.
4. Exception: 1/2" $ or greater steel bolts are not required to be corrosion resistant except in Open Areas of
the Seaward Area.
PRIVATE
RESIDENCE
2803 HIGHCREST DR.
GRAPEVINE, TX
REVISION
06-18-25
GPEC
LLC
GRAND PYRAMID ENGINEERING
CONSULTANTS, LLC
REGISTRATION#F-24236 (TEXAS)
729 CREEKVIEW LN.
COLLEYVILLE, TX 76034
P:(214)574-0911
GPEC
L
L
C
.
C
O
M
-ADDITION-
S0.0
GENERAL NOTES
S0.0
Shear Wall Strapping Detail
Use double
studs at Tie
location
Tension ties may be
installed over sheathing.
See plan for Tension Tie
strap (Simpson MSTC66
shown). Install per
manufacturer's instructions
Nailing not
required at Subfloor.
Use
double
studs at
Tie
location
Alternate Offset Shear Wall Strapping Detail
Use double
studs at Tie
location
See plans for
size of beam.
See plan for Tension Tie
strap (Simpson
MSTC66B3 shown). Bent
strap secured to beam.
See manufacturer's info
for installation spec's.
Alternate Wall Strapping to Beam DetailBCTypical Shear Wall Strapping DetailA
Tension ties may be
installed over sheathing.
See plan for Tension Tie
strap (Simpson MSTC66
shown). Install per
manufacturer's instructions
Tension ties may be
installed over sheathing.
3
Gap to allow for continuous
structural sheathing through
full length of wall.
Perpendicular
Wall per
architecturals
Sheathing thickness
Additional Studs for
nailing to maintain
spacing, as required
Interior Gyp.
Sheathing
8d or 0.131" x 3"
Nails @ 6" O.C.
Edge Nailing per
Sheathing Schedule
Interior Gyp.
Sheathing
Continuous Shear WallA
Sheathing at Perpendicular Wall
B
Continuity Blocking for
Interior Shear Wall
See plans for tie down
(Simpson HTT5-KT
shown). Tie down shall be
secured to stud-pack (see
plan, double stud pack
min.) per manufacturer's
specifications.
Top
View
Drill and epoxy A307
grade all-thread rod with
Simpson SET epoxy or
approved equivalent per
tie down table.
See plans for sheathing
material. Sheathing shall be
continuous across entire
length of shear wall.
Tie
Down
Bolt
Dia.
Embedment
(inches)
HTT4 5/8" 7
HTT5-KT 75/8"
See plans for embedment
depth of tie downs not shown.
Bolted Tie Down Shear Wall Anchor2
Shear wall end stud w/0.131"
x 3" nails at
3" O.C. staggered into end
studs of adjoining shear wall
Alternate tie down location
(HTT tie down shown for
illustrative purposes)
Tie down or strap per plan
(STHD tie down shown for
illustrative purposes)
Nail each member of
triple stud pack together
w/ 0.131" x 3" nails at 3"
O.C. staggered.
Additional stud added as
nailer for interior gyp. board
Shear Walls w/SharedHoldown at Corner6 Note: This detail required for wind speeds greater than 100mph
only. For gable end walls longer than 24ft. in 130mph Exp.C wind
areas, refer to plan for bracing requirements.
Gable End Framing
Attach vertical block to stud
w/(4)0.131"x3" face
nails.
Outlooker
2x vertical blocking in first two ceiling
joist spaces at 48" o.c. Fasten gyp. board to
bottom of blocking at 4" o.c.
8ft. 2x4 strongback nailed into vertical
blocking w/0.131x3" nails at 3"o.c. Nail
strongback into each ceiling joist
w/(2)0.131x3" nails
Double horizontal blocking between continuous
full height studs located at height of flat ceiling
beyond. Block shall be secured to studs
w/(4)0.131"x3" toe-nails each end. As an
alternate, wall may be spliced with double plate
located at height of flat ceiling beyond.
Attach vertical block
to horizontal blocking
or double plate w/A35
clip.
7
Tie Strap Shear Wall Anchor
See plans for tie down
(Simpson STHD14 shown). Tie
down shall be secured to stud-pack
per manufacturer's specifications.
If plans call for shear panels in both directions,
strap tie down shall be secured to corner stud
pack. Only one tie down is required for both
directions. See Details 5 and 6. Tie down may be
installed over sheathing.
Tie down shall be installed to avoid post-tension strands. If no
post-tension strands are located near strap location, 1-#4 x 30"
rebar shall be installed per manufacturer's specs.
See plans for sheathing material.
Sheathing shall be continuous
across entire length of shear wall.
corner stud
pack
1
Double top plate (rake as
required).
Tie down may be
installed over sheathing.
At shear walls extend structural
sheathing to top of gable end
wall.
Tie down or strap per plan (STHD tie
down shown for illustrative purposes)
Alternate tie down location
(HTT tie down shown for
illustrative purposes)
Nail end stud of interior
shear wall into double studs
w/ 0.131" x 3" nails at
3" O.C. staggered.
Double stud nailed together
w/ 0.131" x 3" nails at 3"
O.C. staggered.
Exterior wall, may be
shear wall
These details may be used at a shared tie down condition.
Alternate tie down may be
placed in this location
provided there is a thickened
section of concrete called for
on foundation plan.
Interior/Exterior Shear
Wall w/Shared Holdown5
These details may be used at a shared tie down condition.
10d nails @ 2" o.c. into
all header members 10d toe nail jack stud to
header
2x top plate typ.
Provide full height stud
each side equal to half
of studs interrupted by
the opening
Header refer to header
schedule
2-2x stud
10d nails @ 8" o.c.
2x
blocking
Typical Window & Door Header8
PRIVATE
RESIDENCE
2803 HIGHCREST DR.
GRAPEVINE, TX
REVISION
06-18-25
GPEC
LLC
GRAND PYRAMID ENGINEERING
CONSULTANTS, LLC
REGISTRATION#F-24236 (TEXAS)
729 CREEKVIEW LN.
COLLEYVILLE, TX 76034
P:(214)574-0911
GPEC
L
L
C
.
C
O
M
-ADDITION-
S0.1
TYPICAL FRAMING
DETAILS
2
"
Secure adjoining rafters at
ridges and hips with CS22
w/8" lap at spacing per table.
Alternate: 2x collar tie, spaced and
fastened per table. Ties shall be
located in upper 13 of the attic.
Ridge Strap or Collar Tie Detail13
Top Plate
Rafter per plan.
Plan View
Joist or beam per plans, face
nailed to the rafter per the
Nailing Schedule. Multiple
plies shall be fastened
together.
Typical Roof Framing and Bracing Details
Attach brace to rafter per
Uplift Connection
Schedule.
Attach purlin to brace per
Uplift Connection
Schedule.Rafter
T
-
B
r
a
c
e
Attach rafter to ceiling joist
per Uplift Connection
Schedule.
Attach ceiling joist/beam to
top plate per Uplift
Connection Schedule.
Top plate to stud
connection per Uplift
Connection Schedule
Strap through sub-floor
as necessary per Uplift
Connection Schedule
Bottom plate to foundation
connection per Uplift
Connection Schedule.
Stud to bottom plate
connection (lower floor) per
Uplift Connection Schedule
Joist
Ceiling Ceiling Joist/Beam
Raft
e
r
T-B
r
a
c
e
Attach brace to top plate
or perpendicular beam per
uplift connection schedule.
Attach ceiling joist/beam
to top plate per Uplift
Connection Schedule.
Plate to stud connection
per Uplift Connection Schedule
Attach brace to ceiling
joist/beam per Uplift
Connection Schedule.
2x4 block
intermediate rafter
between braces
Attach block to rafter
w/(3)0.131"x3" nails
Attach purlin to block
w/(3)0.131"x3" nails
CONNECTION NOTES
1. When (2)mechanical fasteners are installed into single ply member or single
stud, fasteners shall be placed on opposite sides of the plate.
2. When more than (2)mechanical fasteners are installed on the same side of
the plate, they shall be installed to a double 2x min.
3. At typical header openings or at beams supporting exterior walls above, refer
to the Uplift Connections at Openings Schedule.
4. An LTS12 or MTS12 twist strap may be used in place of an H2.5A or LSTA9
at condition where connecting elements are at a 45 degree angle.
5. T-Brace shall be constructed w/ 2x6's fastened together w/0.131"x3" nails at
12"o.c.
11
Intermediate Rafter to Purlin Connection
2x4 Blocking between ceiling joists
@ mid span of 2x12 brace.
Secure 2x4 blocking to ceiling
joists with 2 - 10d nails each
end, and to 2x12 brace
with 4 - 10d nails
2x12 Brace, flush with bottom of ceiling
joists, spanning between load bearing
walls perpendicular to exterior stud wall.Exterior Stud Wall
Nail Ceiling joist to
2x12 brace with 10d
nails @ 2'-0" O.C.
1 1/2" x 16ga. Metal Tie
Strap @ every other rafter
w/ Min. 40ksi yield strength
fastened to rafters and 2x12
bracing w/ 5 - 10d nails
(staggered) each.
Secure 2x12 Brace to load
bearing wall top plate with
10 - 10d nails each end.
2"Typ
1 1/4"
1"
1"1"
Rafter
perpendicular
to ceiling joists
Ceiling Joists @
24" O.C.
Add 2nd brace
when exterior wall
length exceeds 12'.
2"Typ
Gyp board
Ceiling
Typical Rafter Tie Detail
2x4 brace w/ length as
required, nailed to each
joist with 2 - 10d nails.
Gyp board Ceiling
Exterior Stud Wall
6 ft - 2x6 @ every
other rafter with 6-10d
common wire nails
(staggered) each.
10d nails @ 6" O.C.
to connect 2x6 and
2x4 braces.
Rafter
perpendicular
to ceiling joists
Secure 2x4 rafter tie to double
joist @ load bearing wall with
6-10d common wire nails.
AlternateB
TypicalA
15
(4) 3/8" Ø Thru-Bolts
with 1" Ø Washers
Top Plate
B
A
A
Perpendicular to Ceiling JoistsBParallel to Ceiling JoistsA
Use Alternate Roof Framing and Bracing where purlin brace cannot reach load bearing wall
and no deflection is desired in ceiling framing or where specifically called out on plans.
Alternate Roof Framing and Bracing Details (Elevated Beam)
Rafter
T
-
B
r
a
c
e
Section A-A
2x4 (min.) blocking under
elevated beam at each end.
(see plan for size)
Elevated beam
Ceiling joist parallel
to elevated beam
CS16 w/14" lap or
(2)CS22 w/ 8" lap
each end, U.N.O.
Rafter T
-
B
r
a
c
e
CS16 w/14" lap or
(2)CS22 w/ 8" lap each
end, U.N.O. on plan
2x bracing on both
sides of elevated beam at each end
1 1/2"
Min. Clear
Section B-B
Connections per Uplift
Connections Schedule
Triple stud pack
below elevated beam
Ceiling joist
perpendicular to
elevated beam
(see plan for size)
Elevated beam
12
Lap
Distance
La
p
Di
s
t
a
n
c
e
La
p
Di
s
t
a
n
c
e
La
p
Di
s
t
a
n
c
e
Triple stud pack
below elevated beam
La
p
Di
s
t
a
n
c
e
CS16 w/14" lap or
(2)CS22 w/ 8" lap each
end, U.N.O. on plan
48" O.C.B<100 24" O.C.C
48" O.C.B110 24" O.C.C
48" O.C.B115 24" O.C.C
B120 24" O.C.C
B125 24" O.C.C
24" O.C.
24" O.C.
Wind Speed
and Exp.
Strap/Collar Tie
Spacing
Rafter to Joist Connection at Sloped Ceilings16
AlternateBTypicalA
Add cripple rafters as
required for full bearing for
joists. Face nail to rafter and
toe nail to top plate.
Add cripple rafters as
required for full bearing, plus
an additional full-height
rafter.
Rafter per plan.
Joist or beam per plans, face
nailed to the rafter per the
Nailing Schedule. Multiple
plies shall be fastened
together.
3
4
4
6
4
6
6
8
4
5
#0.131x3 Nails per
Collar Tie Connection
Roof Rafter at Exterior Wall14
Rafters and joist shall be face
nailed and both shall be
toenailed to top plate per Uplift
Connection Schedule.
Plate to stud connection per Uplift
Schedule (H2.5A shown).
Rafter to plate connection per
Uplift Connection Schedule
(H2.5A shown).
Blocking required where rafters or ceiling joists
have depth to thickness ratio greater than 5:1. For
wind speeds greater than 100 mph, blocking also
required at braced wall panels or shear walls
where noted on plans. Blocking need not be
full-depth, but may have no more than 2" gap at
roof sheathing, except at 2x6 rafters where a 2x4
flat block may be used.
B130 24" O.C.C1
24" O.C.
8
5
1. At 130 mph exp. C ridge strap shall be
upgraded to CS20 w/10" lap.
PRIVATE
RESIDENCE
2803 HIGHCREST DR.
GRAPEVINE, TX
REVISION
06-18-25
GPEC
LLC
GRAND PYRAMID ENGINEERING
CONSULTANTS, LLC
REGISTRATION#F-24236 (TEXAS)
729 CREEKVIEW LN.
COLLEYVILLE, TX 76034
P:(214)574-0911
GPEC
L
L
C
.
C
O
M
-ADDITION-
S0.2
TYPICAL FRAMING
DETAILS
< 6'
12"
32 psf
(3" Max
Width)6
>6' - <8'-3"
>8'-3" - <12'
>12' - <16'-3"
24"36"48"
3 x 3 x 1 4
3 x 3 x 1 4
4 x 3 x 1 4
5 x 312 x 5 16
3 x 3 x 1 4 3 x 3 x 1 4 3 x 3 x 1 4
31 2 x 31 2 x 1 4 4 x 3 x 1 4 4 x 312 x 14
5 x 312 x 5 16 6 x 4 x 5 16
6 x 4 x 3 8 7 x 4 x 1/2
15-8"
7 x 4 x 12
31 2 x 31 2 x 1 4 31 2 x 31 2 x 1 4 31 2 x 31 2 x 1 4
31 2 x 31 2 x 1 4 31 2 x 31 2 x 1 4 4 x 312 x 14
4 x 312 x 1 4 5 x 312 x 14
31 2 x 31 2 x 1 4
6 x 4 x 5 16 6 x 4 x 3 8
5 x 312 x 3 8 7 x 4 x 12 7 x 4 x 12 8 x 4 x 12
31 2 x 31 2 x 1 4 31 2 x 31 2 x 1 4 31 2 x 31 2 x 1 4 4 x 312 x 14
31 2 x 31 2 x 1 4 4 x 312 x 1 4
5 x 312 x 1 4
6 x 4 x 5 16
6 x 4 x 5 16
7 x 4 x 12
6 x 4 x 3 8
8 x 4 x 12
7 x 4 x 12
-----
5 x 312 x 14
5 x 312 x 1 4
5 x 312 x 1 4 5 x 312 x 1 4
Arch Action
3 x 3 x 1 4
31 2 x 31 2 x 1 4
6 x 4 x 5 16
8 x 4 x 12
31 2 x 31 2 x 1 4
6 x 4 x 5 16
8 x 4 x 12
31 2 x 31 2 x 1 4
7 x 4 x 12
-----
4 x 312 x 1 4
5 x 312 x 1 4
40 psf
(4" Max
Width)6
60 psf
(4" Max
Width)6
Masonry
Weight/Width
(NTE)
Opening
Width
_
_
_
_
< 6'
>6' - <8'-3"
>12' - <16'-3"
_
_
_
< 6'
>6' - <8'-3"
>12' - <16'-3"
_
_
_
>8'-3" - <12'_
>8'-3" - <12'_
Height of Masonry Veneer
Loose Lintels for Masonry Support
Steel Lintel:1. All lintels shall be A36 steel, oriented in the strong direction (longer leg vertical).2. All lintels shall extend at least 4 inches beyond each end of the opening.3. The arching action assumes that the weight of the masonry load is transferred around the opening at a 45 degree angle. Thisassumption is valid when there is sufficient masonry on both sides of the opening to carry the load from above and when noopenings interrupt the arch action.4. Deflection is limited to L/600 or 0.30", whichever is less.5. Lintels are designed for supporting non-structural masonry veneer only. Other gravity loads shall be carriedby other structural members. Lintels shall not be attached to header/beams U.N.O.6. Table based on typical sizes and weights. Builder to verify. Contact this office for alternate materials.
7. Masonry shall not extend more than
12" past the edge of the horizontal leg.8. Reference: Brick Industry Association and IRC R703.7.3 .
Nailing ScheduleWall Stud SchedulesComponents and Cladding Wind Pressures
Sheathing and Cladding Attachment Schedule
Ceiling Joist Span Schedule
Maximum Ceiling Joist Spans (Excerpt WFCM Tables 3.25A and 3.25B)
Species Grade Joist Size Limited Attic Storage
16" o.c.24" o.c.
Without Attic Storage
16" o.c.24" o.c.
12'-0"
#2
2x6
2x8
2x10
9'-10" 16'-11" 13'-11"
15'-3" 12'-6"21'-7" 17'-7"
18'-1" 14'-9" 25'-7" 20'-11"
9'-2"
#3
2x6
2x8
2x10
7'-5" 12-11" 10'-6"
11'-6" 9'-5" 16'-3" 13'-3"
14'-0" 11'-5" 19'-9" 16'-1"
SYP
12'-10"
#2
2x6
2x8
2x10
10'-6" 16'-11" 14'-9"
16'-3" 13'-3"22'-4"18'-9"
19'-10"16'-3"26'-0" 22-11"
12'-10"
#2
2x6
2x8
2x10
10'-6" 17'-8" 14'-10"
16'-3" 13'-3" 23'-0"18'-9"
19'-10" 16'-3" 26'-0" 22'-11"
SPF
Rafter Span Schedule
Maximum Rafter Spans (Excerpt WFCM Table 3.26A)
Species Grade Rafter Size 10 psf
16" o.c.24" o.c.
20 psf
16" o.c.24" o.c.
13'-6"
#2
2x6
2x8
2x10
11'-0"11'-8"9'-6"
17-1"13'-11"14'-9"12'-1"
20'-3"16'-6"17'-6"14'-4"
10'-2"
#3
2x6
2x8
2x10
8'-4"8'-10"7'-3"
12'-10"10'-6"11'-2"9'-1"
15'-7"12'-9"13'-6"11'-0"
SYP
14'-4"
#2
2x6
2x8
2x10
11'-9"12'-5"10'-2"
18'-2"14'-10"15'-9"12'-10"
22'-3"18'-2"19'-3"
14'-4"
#2
2x6
2x8
2x10
11'-9"12'-5"10'-2"
18'-2"14'-10"15'-9"12'-10"
22'-3"18'-2"19'-3"15'-8"
SPF
1. Where ceiling joists are not located at the bottom of the attic space, refer to footnote a in the span tables for adjustment factor
2. For hurricane winds of 100 mph or more or non hurricane winds of 110 mph or more refer to adjustment factors below
Pitch
4:12
6:12
8:12
10:12
12:12
Rafter Span Adjustment Factor for Wind Loads (Excerpt from footnotes of WFCM Tables 3.26A-H)
1. For other pitches, refer to the WFCM. Adjustment factor may not be greater than 1.00
110 MPH 120 MPH100 MPH
1.07
1.00
1.23
1.12
1.02
B C
0.96
0.89
1.09
1.00
0.91
0.77
0.72
0.87
0.80
0.73
0.86
0.80
0.98
0.90
0.81
B C B C
0.87
0.81
0.98
0.91
0.83
0.70
0.65
0.79
0.73
0.66
2x6
Roof + Ceiling
12
14
16
18
<10
2x6 @ 16" o.c.
2x6 @ 16" o.c.
2x6 @ 16" o.c.
2x4 @ 16" o.c.
2x4 @ 16" o.c.
20 2x6 @ 8" o.c.
22 2x6 @ 8" o.c.
24 2x6 @ 8" o.c.
2x6 @ 16" o.c.
2x6 @ 16" o.c.
2x6 @ 16" o.c.
2x6 @ 16" o.c.
2x4 @ 16" o.c.
2x6 @ 8" o.c.
2x6 @ 8" o.c.
2x6 @ 8" o.c.
Roof, Ceiling
and one floor
Roof, Ceiling and
two floors
2x6 @ 12" o.c.
2x6 @ 12" o.c.
2x6 @ 16" o.c.
2x6 @ 16" o.c.
2x6 @ 16" o.c.
2x6 @ 8" o.c.
See Engineer
See Engineer
Maximum Stud Length
Maximum Exterior Stud Length
(Excerpt from WFCM Table 3.20A)
Stud
#2
16" O.C.
Stud
#2
2x4
2x6
11'-9"
14'-6"
This table assumes SPF or equivalent. For other material, size, or
spacing combinations, refer to the WFCM.
9'-8"
12'-7"
16'-1"
10'-8"
10'-5"
12'-2"
15'-8"
8'-1"
110 MPH100 MPH 130 MPH90 MPH
13'-6"
18'-0"
120 MPH
11'-1"
13'-3"
17'-1"
8'-10"
Stud Height
(feet)
Max
Framing
Spacing
Min
Sheathing
Thickness
APA Span
Rating
Interior Zone
(Edge/Field)90 mph
B C
100 mph
B C B C B C
110 mph 120 mph
68/68
4/4
6/1276/127
49/49
6/127
4/4
6/127
68/68
6/125
6/126
7/16"
7/16"
23/32" 48/24
1. Perimeter Edge Zone shall be used at roofs within 4 feet of either the roof edge or roof peak. It shall also be used at walls within 4 feet of
outside or re-entrant corners.
2. Sheathing shall be OSB or APA Rated sheathing. Alternate sheathing materials may be used, provided they have code approval for
suitability for the anticipated wind pressures.
3. These are minimum requirements for cladding loads. Refer to notes and plans for wall bracing or shear wall requirements.
4. Refer to WFCM Tables 3.10 through 3.14
5. Reduce field spacing to 6" oc for 120 mph Exp C, and 130 mph Exp C for framing members with specific gravity between 0.42 and 0.49
6. Reduce field spacing to 6" oc for 110 mph, Exp C, 120 mph Exp C, and 130 mph Exp C for framing members with specific gravity between
0.42 and 0.49
7. Reduce spacing to 6" oc for framing members with specific gravity between 0.42 and 0.49
8. Reduce spacing to 4" oc for framing members with specific gravity between 0.42 and 0.49
9. Reduce spacing to 3" oc for framing members with specific gravity between 0.42 and 0.49
10. Reduce spacing to 2" oc for framing members with specific gravity between 0.42 and 0.49
11. For intermediate wind speeds, use the higher wind speed.
12. Roof sheathing shall be fastened with 8d common nails or equivalent.
13. Floor sheathing shall be fastened with 10d common nails or equivalent.
7/16"
16" O.C.
24" O.C.
16" O.C.
24" O.C.
Gable Endwall Rake
Exterior Wall Sheathing
Floor Sheathing
Roof Sheathing 7/16" 24/16 6/12 6/12 6/6 6/6 6/6
6/126/126/126/12
6/6
6/12
6/6
6/126/12
6/12
24/16
24/16
24/16
Fastening Location IRC Table R602.3(1)IBC Table 2304.9.1
Joist to Sill or Girder 3 - 8d (Toenail)3-3" x 0.131" nails (Toenail)
Bridging to Joist 2 - 8d (Toenail each end)2-3" x 0.131" nails (Toenail each end)
Sole Plate to Joist or Blocking 3 - 16d @ 16" oc (Facenail) 3" x 0.131" nails @ 8" oc (facenail)
Top Plate to Stud 2 - 16d (Endnail)3-3" x 0.131" nails (Endnail)
Stud to Sole Plate 3 - 8d or 2 - 16d (Toenail)4-3" x 0.131" nails (Toenail) or
2-3" x 0.131" (Endnail)
Double Studs 10d @ 24" oc (Facenail)3" x 0.131" nails @ 8" oc (Facenail)
Doule Top Plates 10d @ 24" oc (Facenail)3" x 0.131" nails @ 12" oc (Facenail)
Top Plates Laps & Intersections 2 - 10d (Facenail)3-3" x 0.131" nails (Facenail)
Continuous Header, Two Pieces 16d @ 16" oc along each edge -------------------------
Ceiling Joist to Plate 3-8d (Toenail)5-3" x 0.131" nails (Toenail)
Continuous Header to Stud 4 - 8d (Toenail) -------------------------
Ceiling Joist, Laps over Partitions 3 - 10d (Facenail)4-3" x 0.131" nails (Facenail)
Ceiling Joists to Parallel Rafters 3 - 10d (Facenail)4-3" x 0.131" nails (Facenail)
Built - Up Corner Studs 10d @ 24" oc 3" x 0.131" nails @16" oc
Built - Up girders & beams 10d @ 32" oc Top, Bot &3" x 0.131" nails @ 24" oc (Face nail)
Staggered - 2 nails @ ends &at Top and Bottom and Staggered
each splice 3- 3" x 0.131" nails ( Face nail)
at Ends and at each splice
Built - up Wood Columns 16d @ 8" oc (2x4's); 2 rows 16d @ -------------------------
8" oc for 2x6 or greater
Roof or Floor Truss to Plate 3 - 8d (Toenail)3-3" x 0.131" nails (Toenail)
Ledger Strip 3 - 16d (Facenail)4-3" x 0.131" nails
Blocking @ joists/rafters to Top Plate 3 - 8d (Toenail)3-3" x 0.131" nails (Toenail)
Rim Joist to Top Plate 8d @ 6" oc (Toenail)3" x 0.131" nails @ 6" oc (Toenail)
Rafter to Plate 2 - 16d (Toenail)3-3" x 0.131" nails (Toenail)
Collar Tie to Rafter 3 - 10d (Facenail)4-3" x 0.131" nails (Facenail)
Jack Rafter to Hip 4 - 16d (Toenail)/3 - 16d (Facenail) 4-3" x 0.131" nails (Toenail) &
3-3" x 0.131" nails (Facenail)
Roof Rafter to 2x Ridge Bm 4 - 16d (Toenail)/3 - 16d (Facenail) 3-3" x 0.131" nails (Toenail) &
3-3" x 0.131" nails (Facenail)
Rafter Ties to Rafters 3 - 8d (Facenail) --------------------------
Joist to Band Joist 3 - 16d (Facenail)4-3" x 0.131" nails
1. Assumes SPF stud grade or better.
2. Balloon frames or tall walls (greater than 12' max) shall be #2 grade or
better.
3. For exterior walls exposed to wind, stud lengths shall be limited by the
following.
12'-0"
18'-0"
Maximum Allowable Length & Spacing of Load Bearing Wall Studs
- Allowable stud length exceeds 20 feet.
Maximum Stud Length
Maximum Exterior Stud Length
(for walls with wood structural sheathing)
(Excerpt from WFCM Table 3.20B)
Stud
#2
16" O.C.
Stud
#2
2x4
11'-9"
15'-10"
This table assumes SPF or equivalent. For other material, size, or
spacing combinations, refer to the WFCM.
12'-7"
11'-2"11'-4"
17'-6"
10'-5"
13'-3"
16'-9"
9'-4"
110 MPH100 MPH 130 MPH90 MPH
13'-6"
19'-8"
120 MPH
11'-1"
14'-5"
17'-9"
10'-2"12'-10"
18'-10"
- Allowable stud length exceeds 20 feet.
B C
130 mph
68/68
310/310
6/127
Perimeter Edge Zone - Fastener Spacing (Edge/Field)
6/127
1. Reference: ASCE 7-05, Figure 6.3. For wind speeds less than 100 mph, refer to IRC Table R301.2(2).
2. Plus and minus signs signify pressures acting toward and away from the building surfaces. Pressures shall not be taken as less than 10 psf.
3. Pressures are taken from Zone 3 for roofs and Zone 5 for walls.
4. Linear interpolation is allowed for effective wind area only. For intermediate wind speeds, use the higher wind speed. For other conditions,
contact this office.
6/6
6/12
130 MPH
B C
0.79
0.75
0.90
0.83
0.76
0.63
0.60
0.72
0.66
0.61
Components and Cladding Wind Pressures (psf)
Exposure B - less than 25' MRH Exposure C - less than 25' MRH
110 mph 120 mph
-55.0
Exposure C - less than 15' MRH
Flat - 1.5:12
1.5 - 6:12
130 mph
10
20
50
100
10
20
50
100
10
20
50
100
10
20
50
100
110 mph 120 mph 130 mph 110 mph 120 mph 130 mph
500
Wall
Roof Pitch (sf)
+8.9
-45.5+8.3
-33.1+7.6
-23.6+7.0
-65.4+10.5
-54.2+9.9
-39.3+9.0
-28.1+8.3
-76.8+12.4
-63.6+11.6
-46.2+10.6
-33.0+9.8
-51.3+12.5
-47.9+11.4
-43.5+10.0
-40.2+8.9
-61.0+14.9
-57.1+13.6
-51.8+11.9
-47.9+10.5
-71.6+17.5
-67.0+16.0
-60.8+13.9
-56.2+12.4
-25.5+19.9
-24.3+19.4
-22.9+18.6
-21.8+18.1
-30.3+23.7
-29.0+23.0
-27.2+22.2
-25.9+21.5
-35.6+27.8
-34.0+27.0
-32.0+26.0
-30.4+25.2
-29.1+21.8
-27.2+20.8
-24.6+19.5
-22.6+18.5
-18.1+16.2
-34.7+25.9
-32.4+24.7
-29.3+23.2
-26.9+22.0
-21.5+19.3
-40.7+30.4
-38.0+29.0
-34.3+27.2
-31.6+25.9
-25.2+22.7
-66.6+10.8
-55.1+10.0
-40.1+9.2
-28.6+8.5
-79.1+12.7
-65.6+12.0
-47.6+10.9
-34.0+10.0
-92.9+15.0
-77.0+14.0
-55.9+12.8
-39.9+11.9
-62.1+15.1
-58.0+13.8
-52.6+12.1
-48.6+10.8
-73.8+18.0
-69.1+16.5
-62.7+14.4
-58.0+12.7
-86.6+21.2
-81.1+19.4
-73.6+16.8
-68.0+15.0
-30.9+24.1
-29.4+23.5
-27.7+22.5
-26.4+21.9
-36.7+28.7
-35.1+27.8
-32.9+26.9
-31.3+26.0
-43.1+33.6
-41.1+32.7
-38.7+31.5
-36.8+30.5
-35.2+26.4
-32.9+25.2
-29.8+23.6
-27.3+22.4
-21.9+19.6
-42.0+31.3
-39.2+29.9
-35.5+28.1
-32.5+26.6
-26.0+23.4
-49.2+36.8
-46.0+35.1
-41.5+32.9
-38.2+31.3
-30.5+27.5
-74.3+12.0
-61.4+11.2
-44.7+10.3
-31.9+9.5
-88.3+14.2
-73.2+13.4
-53.1+12.2
-37.9+11.2
-103.7+16.7
-85.9+15.7
-62.4+14.3
-44.6+13.2
-69.3+16.9
-64.7+15.4
-58.7+13.5
-54.3+12.0
-82.4+20.1
-77.1+18.4
-69.9+16.1
-64.7+14.2
-96.7+23.6
-90.5+21.6
-82.1+18.8
-75.9+16.7
-34.4+26.9
-32.8+26.2
-30.9+25.1
-29.4+24.4
-40.9+32.0
-39.2+31.1
-36.7+30.0
-35.0+29.0
-48.1+37.5
-45.9+36.5
-43.2+35.1
-41.0+34.0
-39.3+29.4
-36.7+28.1
-33.2+26.3
-30.5+25.0
-24.4+21.9
-46.8+35.0
-43.7+33.3
-39.6+31.3
-36.3+29.7
-29.0+26.1
-54.9+41.0
-51.3+39.2
-46.3+36.7
-42.7+35.0
-34.0+30.6
DF-L
Load Bearing Walls (Excerpt IRC Table R602.3.1)
DF-L
1. On shear walls and diaphragms, nails shall be placed not less than 3/8 inch from the panel edge.
Where exterior walls are sheathed with wood structural panels, max
stud lengths shall be per the following.
68/68 68/68
68/68 68/68 68/68 68/68 68/68
49/49 49/49 49/49
49/49 49/49
>6 - 12:12
12
13
PRIVATE
RESIDENCE
2803 HIGHCREST DR.
GRAPEVINE, TX
REVISION
06-18-25
GPEC
LLC
GRAND PYRAMID ENGINEERING
CONSULTANTS, LLC
REGISTRATION#F-24236 (TEXAS)
729 CREEKVIEW LN.
COLLEYVILLE, TX 76034
P:(214)574-0911
GPEC
L
L
C
.
C
O
M
-ADDITION-
S0.3
TYPICAL FRAMING
SCHEDULES
Sill Plate Anchorage Schedule
Sheathing Schedule / Shear Connection ScheduleUplift Connection Schedule
101 to 115 mph Exp. B 110 to 115 mph Exp. C 116 to 130 mph Exp. C
Rafter to exterior wall (3) 0.131"x3" toenails H2.5A + (3) 0.131"x3" toenails
- Plate to stud -H2.5A (every third stud)H2.5A (every other stud)
- Stud to bottom plate -H2.5A (every third stud)
Brace to rafter (6) 0.131"x3" face nails (6) 0.131"x3" face nails (6) 0.131"x3" face nails
Brace to top plate of interior
wall or perpendicular beam H2.5A H2.5A H2.5A
Brace to ceiling joist/beam (7) 0.131"x3" toe nails (4) 0.131"x 3" toe nails
+ LSTA9 strap
Ceiling joist/beam to top plate
of interior wall (supporting 1 brace)H2.5A H2.5A
- Top plate to stud --
- Stud to bottom plate -
Ceiling joist/beam to top plate of interior and
exterior wall (supporting 2 braces)(2) H2.5A
- Plate to stud
- Stud to bottom plate (2) H2.5A
- Bottom plate to foundation (2) Hilti X-CP 72
Ceiling joist/beam to top plate of interior
and exterior wall (supporting 3+ braces)
- Plate to stud
- Stud to bottom plate (4) H2.5A
- Bottom plate to foundation
H2.5A (every other stud)
(2) H2.5A
(2) H2.5A
(4) H2.5A
(2) H2.5A
(2) H2.5A
(2) H2.5A
- Through sub-floor -CS22 w/8" Lap (every third stud) CS22 w/8" Lap (every third stud)
- Through sub-floor -
- Through sub-floor CS22 w/8" Lap
- Through sub-floor
Rafter to ceiling joist (4) 0.131"x3" face nails (6) 0.131"x3" face nails (8) 0.131"x3" face nails
Typical ceiling joist to wall connection (5) 0.131"x3" toe nails (5) 0.131"x3" toe nails (5) 0.131"x3" toe nails
H2.5A + (3) 0.131"x3" toenails
H2.5A
-
-
CS16 w/12" Lap or FSC
CS22 w/8" Lap or FSC
Purlin to brace (3) 0.131"x3" face nails (3) 0.131"x3" face nails (3) 0.131"x3" face nails
-
-
-
H2.5A
H2.5A
H2.5A
H2.5A
CS22 w/8" Lap
CS16 w/12" LapCS22 w/8" Lap
H2.5A
(4) 0.131"x 3" toe nails
+ LSTA9 strap
(3) H2.5A
(3) H2.5A
(3) H2.5A
(3) H2.5A
Top Plate to Jack Stud(s)
Through Subfloor
Jack Stud(s) to Sill Plate
Sill Plate to Foundation
Hardware Option 1
CS22 w/8" Lap
CS22 w/8" Lap
H2.5A
Hardware Option 2
CS22 w/8" Lap
CS22 w/8" Lap
(2) H2.5A
Hardware Option 3
CS18 w/12" Lap
(3) H2.5A
Hardware Option 4
CS16 w/14" Lap
(4) H2.5A
CS18 w/12" Lap CS16 w/14" Lap
Wind Speed Exp.
≤100 B
C
105 B
C
(2) Hilti X-CP 72 3/8"Ø THD w/2x2x1/4" thick washer6
- --
5ft - 9ft > 9ft - 18ft > 18ft - 26ft -
7ft - 13ft > 13ft - 25ft --
5ft - 7ft > 7ft - 15ft > 15ft - 23ft
Connection Type
1. Hilti X-CP 72 "Shots" or equivalent shall have min. allowable tension capacity of 165 lbs. Shots shall be spaced at 2-3/4" O.C. with the first fastener spaced 2" from stud
or post. Split total number of shots equally on both sides of stud or post where possible. Shots called for in this table shall be in addition to other anchorage called for in
other notes, schedules, tables, or details in the structural drawings.
2. For uplift connection requirements at covered patios refer to Covered Patio Post Uplift Connection Table.
3. Uplift connections per Table above not required for headers in portal frames. Portal frame detail requirements resolve uplift forces.
4. Uplift connections from top plate down to header(through cripple studs) shall be per the uplift connection schedule.
5. (2)CS22 w/ 8" lap may be substituted for CS16 w/ 14" lap.
6. (2)2x2x1/8 washers may be used as an alternate.
≤ 100 mph Exp. B
Co
n
n
e
c
t
i
o
n
s
g
o
v
e
r
n
e
d
b
y
I
R
C
o
r
I
B
C
p
r
e
s
c
r
i
p
t
i
v
e
g
u
i
d
e
l
i
n
e
s
.
Re
f
e
r
t
o
N
a
i
l
i
n
g
S
c
h
e
d
u
l
e
f
o
r
c
o
n
n
e
c
t
i
o
n
r
e
q
u
i
r
e
m
e
n
t
s
.
B
C
B
C
B
C
B
C
110
115
120
125
> 11ft - 21ft
> 7ft - 14ft
> 9ft - 18ft
> 6ft - 12ft
> 8ft - 16ft
> 5ft - 11ft
> 7ft - 14ft
> 4ft - 10ft
> 21ft - 31ft
> 14ft - 21ft
> 18ft - 27ft
> 12ft - 19ft
> 16ft - 24ft
> 11ft - 17ft
> 14ft - 21ft
> 10ft - 15ft
> 24ft - 32ft
> 17ft - 23ft
> 21ft - 28ft
> 15ft - 21ft
6ft - 11ft
4ft - 7ft
5ft - 9ft
3ft - 6ft
4ft - 8ft
0ft - 5ft
4ft - 7ft
0ft - 4ft
-
-
> 21ft - 28ft
-
> 19ft - 25ft
Uplift Connections at Openings Schedule
1. Braced wall panels shall be a minimum of 48" wide, except for Method 1 which shall be a continuous diagonal brace from top to bottom plate and Method 5 single sided gypsum which shall be a
minimum of 96" wide, U.N.O.
2. Per Details 18A and 20A only; in addition to toe-nails add A35 @ 24" O.C. for Condition A. As an alternate for Condition B nails may be spaced at 3" O.C. with an A35 @ 48" O.C.
3. For exterior walls, the edge:field nailing requirements in this schedule must be compared to the general edge:field nailing requirements in the Sheathing and Cladding Attachment Schedule on Sheet
FR-0.2. The most strict requirement shall govern.
4. Gable end wall rakes shall be fastened with the more restrictive edge:field nailing per this table or the Sheathing and Cladding Attachment Schedule on Sheet FR-0.2.
-
Anchorage Options
Shear Wall
A
12" Ø anchor bolts
MASA anchors
Hilti X-CP 72(exterior walls
Hilti X-CP 72 (interior walls)
B C D E F
28"
15"
5"
4"
34"
18"
7"
5"
72"
34"
48"
12"
46"
24"
14"
7"
72"
32"
48"
12"
72"
32"
48"
18"
Non-Shear Wall
90 mph 100 mph 105 mph 110 mph 115 mph 120 mph 125 mph
B C
72"
B C
68"
B C
60"
B C
56"
B C
70" 50"
B C
64" 48"
B C
58"44"72" 72"72"72"
1. Refer to Note 5 in Section 4.5 of the General Notes on Sheet FR-0.1 for anchor bolt installation requirements.
2. Hilti X-CP 72 "shots" or equivalent shall have a min. allowable shear value of 250 lbs. Begin spacing fasteners 2" from end studs of shear wall.
3. Interior shear walls are assumed to have powder actuated sill anchorage. If 1/2" $ bolts or other embedded connection will be used, either due to builder preference or local code, the builder shall
contact this office prior to concrete placement. This is necessary to ensure minimum concrete coverage for required embedment depth of alternate anchorages.
4. Hilti X-CP 72 "shots" at exterior shear walls are required in addition to 1/2" $ anchor bolts or MASA specified for "non-shear wall" installation.
5. Sill plate anchorage shall be the more restrictive of the applicable shear wall and non-shear wall requirements.
6. For sill plates anchored with MASA anchors, (2) Hilti X-CP 72 "shots" shall be placed for each 4'-0" braced wall panel specified on the plans.
Nominal 1" by 4" continuous diagonal
braces let in to the top and bottom plates
and the intervening studs or approved
metal strap devices
(Method 1)
0.113" Red or Blue Thermo-ply
on exterior face and 1/2"
Gypsum Wall Board on interior face
1/2" or 1" DOW Styrofoam SIS Structural
Insulated Sheathing with 1/2" Gypsum
Wall Board on interior face
7/16" Oriented Strand Board4
(OSB) or APA Rated Sheathing
Single Sided12" Gypsum Wall Board
Portal Frame- 7/16" Oriented
Strand Board (OSB) and min.
dbl. 2x12 header
Engineered Sheathing
Vertical or Horizontal
Orientation
Thermo-ply: Vertical
Gypsum: Vertical or
Horizontal
Vertical or Horizontal
Vertical or Horizontal
Vertical
At sheathing
joints, blocking
req'd at panel
edges
Yes
No
Yes
Yes
Yes
Fastening
(Fastener, Spacing [in-o.c.} Edge : Field)
8d, 3:*3
5d cooler or wallboard nails, 4:4
or 1-1/4" drywall screws, 4:12
8d, 4:*3
8d, 6:*3
Sill Plate
Anchorage
A
B
C
3"/9"/16"
2"/10"/18"
Thermo-ply: 1"x1-1/4"x16ga staples, 3:3
Gypsum: 5d cooler nails. 8:8
1-1/4" drywall screws: 12:12
DOW SIS: 1/2" or 1" crown x 16ga
staples, 3:3
Gypsum: 5d cooler nails, 7:7
1-1/4" drywall screws, 12:12
8d, 3:3
Prescriptive Wall Panel Sheathing
(Bracing Method
per IRC Section 602.10.3)
Orientation
See Detail 8 See Detail 8
D
D
F
7/16" Oriented Strand Board
(OSB) or APA Rated Sheathing
(Method 3)
1/2" or 25/32" thick structural fiberboard
sheathing
(1/2" FiberBrace or 1/2" QuietBrace
acceptable)
(Method 4)
1/2" Gypsum Wall Board
(Interior Application)
(Method 5)
0.113" Red or Blue Thermo-ply
on exterior face and 1/2" Gypsum
Wall Board on interior face
(ICC approved prescriptive
alternate material)
1/2" or 1" DOW Styrofoam SIS Structural
Insulated Sheathing with 1/2" Gypsum
Wall Board on interior face
(ICC approved prescriptive
alternate material)
angled ≤60° & ≥ 45°
from the horizontal.
Vertical
Vertical or Horizontal
Vertical or Horizontal
No
Yes
Yes
No
Blocking req'd at
panel edges
Fastening
(Fastener, Spacing
Bottom Plate
anchorage at
Foundation
Yes
Yes
2-8d (2 1/2" x 0.131") nails or
2-16ga. wire staples (1 3/4" long, min. 7/16"$
crown width),
each stud
8d, 6:12
1 1/2" galvanized roofing nails,
8d common (2 1/2" x 0.131") nails, or 16ga.
corrosion resistant staples (1 1/2" long, min.
7/16"$ crown width),
3:6
5d cooler or wallboard nails, 7:7
or 1-1/4" drywall screws, 12:12
1-1/4" Type W or S Screws,
7:7
1/2" Gypsum Sheathing
(Exterior Application)
(Method 5)
Vertical or Horizontal
Vertical
Vertical or Horizontal
Yes
Thermo-ply: 1"x1-1/4"x16ga staples, 3:3
Gypsum: 5d cooler nails. 8:8
1-1/4" drywall screws: 12:12
DOW SIS: 1/2" or 1" crown x 16ga
staples, 3:3
Gypsum: 5d cooler nails, 7:7
1-1/4" drywall screws, 12:12
F
F
F
F
F
F
F
Double Sided12" Gypsum Wall Board Vertical or Horizontal No
5d cooler or wallboard nails, 4:4
or 1-1/4" drywall screws, 4:12 E
2"/9"/-
See Detail 8
Bottom PlateTop Plate
2"/10"/-
3"/16"/30"
4"/24"/48"
10"/48"/96"8"/48"/-
3"/16"/30"
3"/16"/-
3"/16"/-
6"/24"/-
Opening Width Opening Width Opening Width Opening Width
Options include one of the following:
(0.131"x3" nails or LPT4 clip or Ladder Blocking)
Joist to Plate Attachment (Fastener Spacing)
Bottom PlateTop Plate
Options include one of the following:
(0.131"x3" nails/LPT4 clip/Ladder Blocking)
6"/48"/48"
6"/48"/48"
6"/48"/48"
6"/48"/48"
6"/48"/48"
6"/48"/48"
6"/48"/48"
6"/48"/-
6"/48"/-
6"/48"/-
6"/48"/-
6"/48"/-
6"/48"/-
6"/48"/-
Joist to Plate Attachment (Fastener Spacing)
6"/24"/48"6"/24"/-
B
C130 > 6ft - 12ft
> 4ft - 10ft
> 12ft - 19ft
> 10ft - 15ft
> 19ft - 26ft
> 15ft - 20ft
3ft - 6ft
0ft - 4ft 130 mph
B C
54" 40"
(4) Hilti X-CP 72 (5) Hilti X-CP 72
(4) Hilti X-CP 72 (7) Hilti X-CP 72 (7) Hilti X-CP 72
(4) Hilti X-CP 72 (6) Hilti X-CP 72
1. Hilti X-CP 72 "Shots" or equivalent shall have min. allowable tension capacity of 165 lbs. Shots shall be spaced at 2-3/4" O.C. with the first fastener spaced 2" from
stud or post. Split total number of shots equally on both sides of stud or post where possible. Shots called for in this table shall be in addition to other anchorage called
for in other notes, schedules, tables, or details in the structural drawings.
2. CS22 w/8" lap may be substituted for LSTA9 and (2)CS22 w/ 8" lap may be substituted for CS16 w/ 12" lap.
3. Refer to Detail 11 connection notes for connector substitutions at 45 degree angle connections
72"58"50"46" 60"42"52" 38" 48" 36"72" 72"72"66"44"34"
6
PRIVATE
RESIDENCE
2803 HIGHCREST DR.
GRAPEVINE, TX
REVISION
06-18-25
GPEC
LLC
GRAND PYRAMID ENGINEERING
CONSULTANTS, LLC
REGISTRATION#F-24236 (TEXAS)
729 CREEKVIEW LN.
COLLEYVILLE, TX 76034
P:(214)574-0911
GPEC
L
L
C
.
C
O
M
-ADDITION-
S0.4
TYPICAL FRAMING
SCHEDULES
Floor Joists at Interior Shear/Braced Wall Panel
Floor joists per plan
Fasteners along shear wall
per Sheathing Schedule
Sheathing per plan
(2) 2x4 (side by side) horizontal
ladder blocking spaced per
Sheathing Schedule
(4) 0.131"x 3" nails
through each 2x ladder
block into top plate of
shear wall.
Sheathing per plan
Floor joists
per plan
Floor sheathing
Floor sheathing
A Typical
B Alternate
Joists parallel to shear wall
19
LPT4 clip into each block
Where floor system is parallel to wall, installation is similar except that continuous rim board shall be
replaced with minimum double joists for full bearing.
At an interior wall, installation is similar except that sheathing cannot typically be continuous through
the sub floor. Where floor system is parallel to wall and joists cannot be installed under the wall,
blocking shall be installed per Detail 21.
Floor Joist at Bearing Wall
Joists Perpendicular to Wall
20
Full depth blocking only required where ceiling
joists have a depth to thickness ratio greater
than 5:1. Blocking also required at interior
braced wall panels or shear walls. Refer to
Sheathing Schedule for fastening.
Ceiling joists shall be
lapped min. 3". Refer to
Nailing Schedule for
fastening to top plate.
Ceiling Joists at Interior Wall17
Joists Perpendicular to Wall
Blocking at Plumbing Penetration21
Verify permitted
holes in floor joists.
Full depth ladder blocking not more
than 48" O.C. w/(3)0.131"x3" end
nails each side.
Offset joist to allow for
plumbing penetration.
(3) 0.131"x3"
end nails into
each 2x block, typ.
(2) 2x4 (side by side)
horizontal ladder blocking
spaced per Shear
Connection Schedule
(4) 0.131"x 3" nails through
each 2x ladder block into top
plate of braced wall panel or
shear wall.
Ceiling or
floor joists
per plan
Ceiling joists per plan
Fasteners along braced wall
panel or shear wall per
Shear Connection Schedule
Ceiling Joists at Interior Shear/Braced Wall Panel
A Typical
B Alternate
Joists parallel to wall. Ladder blocking only
required at braced wall panels and shear walls.
18
<15ft beam(s)
Center PostCorner Post
<12ft beam(s)
Center PostCorner Post
<10ft beam(s)
Center PostCorner Post
Beam to Post
Post to Foundation100 mph
B
CS22 w/6" Lap
EPB44T
Beam to Post
Post to FoundationC CS22 w/6" Lap CS22 w/6" Lap CS22 w/7" Lap CS22 w/7" LapCS22 w/6" Lap
EPB44T EPB44T EPB44T EPB44T EPB44T
Covered Patio Post Uplift Connection Table
Beam to Post
Post to Foundation110 mph
B
Beam to Post
Post to FoundationC
Beam to Post
Post to Foundation115 mph
B
Beam to Post
Post to FoundationC
Beam to Post
Post to Foundation120 mph
B
Beam to Post
Post to FoundationC
Beam to Post
Post to Foundation125 mph
B
Beam to Post
Post to FoundationC
CS22 w/6" Lap
EPB44T
CS22 w/6" Lap CS22 w/6" Lap CS22 w/6" Lap CS22 w/6" LapCS22 w/6" Lap
EPB44T EPB44T EPB44T EPB44T EPB44T
CS22 w/6" Lap
EPB44T
CS22 w/6" Lap CS22 w/7" Lap CS22 w/8" Lap CS22 w/8" LapCS22 w/7" Lap
EPB44T EPB44T EPB44T EPB44T ABU44
CS22 w/6" Lap
EPB44T
CS22 w/6" Lap CS22 w/6" Lap CS22 w/7" Lap CS22 w/7" LapCS22 w/6" Lap
EPB44T EPB44T EPB44T EPB44T EPB44T
CS22 w/7" Lap
EPB44T
CS22 w/7" Lap CS22 w/8" Lap CS16 w/10" Lap CS16 w/10" LapCS22 w/8" Lap
EPB44T EPB44T ABU44 EPB44T ABU44
CS22 w/6" Lap
EPB44T
CS22 w/6" Lap CS22 w/6" Lap CS22 w/8" Lap CS22 w/8" LapCS22 w/6" Lap
EPB44T EPB44T EPB44T EPB44T ABU44
CS22 w/8" Lap
EPB44T
CS22 w/8" Lap
EPB44T EPB44T ABU44 EPB44T ABU44
CS22 w/6" Lap
EPB44T
CS22 w/6" Lap CS22 w/7" Lap CS22 w/8" Lap CS22 w/8" LapCS22 w/7" Lap
EPB44T EPB44T EPB44T EPB44T ABU44
CS22 w/8" Lap
EPB44T
CS22 w/8" Lap
ABU44 EPB44T ABU44 EPB44T ABU44
CS16 w/10" Lap CS16 w/10" Lap CS16 w/10" Lap CS16 w/10" Lap
CS16 w/10" Lap CS16 w/10" Lap CS16 w/10" Lap CS16 w/10" Lap
Beam to Post
Post to Foundation130 mph
B
Beam to Post
Post to FoundationC
CS22 w/7" Lap
EPB44T
CS22 w/7" Lap CS22 w/8" Lap CS22 w/10" Lap CS22 w/10" LapCS22 w/8" Lap
EPB44T EPB44T EPB44T EPB44T ABU44
CS22 w/8" Lap
EPB44T
CS22 w/8" Lap
ABU44 EPB44T ABU44 EPB44T ABU44
CS16 w/10" Lap CS16 w/10" Lap CS16 w/10" Lap CS16 w/10" Lap
Beam to Post
Post to Foundation90 mph
B
CS22 w/6" Lap
EPB44T
Beam to Post
Post to FoundationC CS22 w/6" Lap CS22 w/6" Lap CS22 w/6" Lap CS22 w/6" LapCS22 w/6" Lap
EPB44T EPB44T EPB44T EPB44T EPB44T
(4)Toenails CS22 w/6" Lap CS22 w/6" Lap CS22 w/6" Lap CS22 w/6" Lap
EPB44T EPB44T EPB44T EPB44T
CS22 w/6" Lap CS22 w/6" Lap CS22 w/6" Lap CS22 w/6" Lap CS22 w/6" LapCS22 w/6" Lap
EPB44T EPB44T EPB44T EPB44T EPB44T
(8)Toenails
(8)Toenails
(5)Toenails
(8)Toenails
Floor Joists Parallel to Wall
Covered Patio Beam to Post Connection22
Beam to Center PostBBeam to Corner PostA
Beam per plan.Beam per plan, with
continuous beam two
straps are still required.
La
p
Di
s
t
a
n
c
e
La
p
Di
s
t
a
n
c
e
La
p
Di
s
t
a
n
c
e
La
p
Di
s
t
a
n
c
e
Strap per Covered
Patio Post Uplift
Connection Table.
Corner Post Center Post
Strap per Covered
Patio Post Uplift
Connection Table.
Post base per Covered
Patio Post Uplift Connection
Table below (EPB44T
shown). Anchor bolt may be
cast in place or post
installed w/epoxy.Treated bearing block
Secure post to bearing block
w/(8)toenails 0.131"x3".
Secure bearing block to
foundation w/pneumatic
fasteners.
Covered Patio Post to Foundation Connection23
Post Base ConnectionBToenailed ConnectionA
Post Post
Note: This connection may be
used in wind speeds >100 mph.
Note: This connection may be
used in wind speeds <100 mph.
Floor JoistsEdge nailing for wall
sheathing above.
Refer to Nailing Schedule for standard nailing
requirements between rim board and plates
above and below (sheathing need not be
continuous through the sub floor).
Continuous rim
board (shown) or
full depth blocking
between floor
joists.Edge nailing for wall
sheathing below.
Refer to Sheathing Schedule for
LTP4 spacing between rim board and
plates above and below (sheathing
need not be continuous through the
sub floor).
Floor Joists
Continuous rim
board (shown) or
full depth blocking
between floor
joists.
Floor Joists
Continuous rim
board (shown) or
full depth blocking
between floor
joists.
Edge nailing for wall sheathing
above (sheathing must be
continuous across sub floor to
top plate below).
Rim board attachment may be
omitted when sheathing is
continuous across the sub floor.
Edge nailing for wall
sheathing below.
For braced wall panels and/or shear
walls, refer to the Sheathing Schedule
for nailing requirements between rim
board and plates above and below.
Alternate Sheathing ConnectionC
Alternate LTP4 ConnectionB
Typical Nailed ConnectionA
A35 clip as
required per
Shear Connection
Schedule.
1. At shear walls or braced walls install full depth blocking directly on wall
between ladder blocking for length of shear wall or braced wall. Fasten
blocking per Sheathing Schedule/Shear Connection Schedule.
1. Toenail connections shall use 0.131"x3" nails or larger.
2. Post bases specified above assume a 4" solid post, for built-up posts or larger posts a connection with equivalent or greater capacity may be
used.
3. Post caps with an equivalent capacity as the specified straps are acceptable.
4. The above table assumes min. SPF lumber or equivalent for posts and beams. For cedar or any lumber with design values less than SPF
contact the structural engineer.
5. The above table assumes a patio depth of 10ft. in conjunction with the beam lengths specified. If any of these dimensions are exceeded
contact the structural engineer.
PRIVATE
RESIDENCE
2803 HIGHCREST DR.
GRAPEVINE, TX
REVISION
06-18-25
GPEC
LLC
GRAND PYRAMID ENGINEERING
CONSULTANTS, LLC
REGISTRATION#F-24236 (TEXAS)
729 CREEKVIEW LN.
COLLEYVILLE, TX 76034
P:(214)574-0911
GPEC
L
L
C
.
C
O
M
-ADDITION-
S0.5
TYPICAL FRAMING
SCHEDULES
UPUP
33
'
-
0
"
2'
-
0
"
3'
-
1
1
"
2'
-
5
"
12'-9"22'-8"
5'
-
1
1
"
2'-0"2'-0"4'-8"2'-0"14'-0"10'-11"2'-0"
11
'
-
1
0
"
11
'
-
4
"
9'
-
1
0
"
1'-3"9'-8"2'-0"
1014"
2'-0"9'-9"1'-0"
3'
-
4
"
15
'
-
8
"
14
'
-
0
"
38
'
-
1
1
"
1-
1
/
2
"
SL
1-
1
/
2
"
SL
2'
-
0
"
SY
P
#
2
6
X
6
P
O
S
T
W/
P
B
6
6
P
O
S
T
B
A
S
E
AN
C
H
O
R
SY
P
#
2
6
X
6
P
O
S
T
W/
P
B
6
6
P
O
S
T
B
A
S
E
ANC
H
O
R
HDU4
HDU4
HDU4
HDU4
37'-7"
EXISTING STRUCTURE
EXISTING STRUCTURE
EXISTING STRUCTURE
3
S1.1
2
S1.1
7
S1.1
7
S1.1
1
S1.1
3
S1.1
2
S1.1
1
S1.1
4
S1.1
4
S1.1
8
S1.1
9
S1.1
STORM SHELTER MANUFACTURER
TO VERIFY SLAB THICKNESS FOR
ANCHOR BOLTS
GENERAL NOTES
I. SITE
A. THE NET ALLOWABLE SOIL BEARING CAPACITY IS1500PSF.
B. THE FOUNDATION DESIGN IS BASED UPON GEOTECHNICAL REPORT
NO.252019 (REVISED) BY GLOBE DATED ON MAY 29, 2025.
THE GRADE BEAMS SHALL BE EMBEDDED A MINIMUM OF 18 INCHES
BELOW FINISHED GRADE SUBGRADE. CONTRACTOR SHALL READ AND
BE FAMILIAR WITH THE PROJECT GEOTECHNICAL REPORT PRIOR TO
BEGINNING EARTHWORK. THE SUBGRADE SHALL BE CHEMICALLY
INJECTED IN CONFORMANCE WITH THE MATERIAL, METHODS AND
THE TEST IN THE ABOVE MENTIONED SOIL REPORT.
C. FINE GRADING UNDER SLAB SHALL BE TRIMABLE, COMPACTABLE,
GRANULAR FILL (NOT SAND).
D. A 6 MIL. VAPOR BARRIER(0.01 PERM MAXIMUM PER ASTM E1745)
SHALL BE PROVIDED ABOVE THE FINE GRADING. SUBSTITUTIONS
SHALL BE APPROVED IN WRITING BY ENGINEER OF RECORD.
E. CONTRACTOR SHALL BRACE GRADE BEAM WHILE PLACING BACKFILL
OR FILL MATERIAL.
II. CONCRETE
A. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF
3000 PSI AT 28 DAYS.
B. ALL SLABS TO RECEIVE FLOOR COVERINGS SHALL HAVE A MAXIMUM
WATER/CEMENTITIOUS MATERIAL RATIO OF 0.45, OR PROVIDE OTHER
TOPICAL
MEANS OF MOISTURE RESISTANCE ACCEPTABLE TO FLOORING
MANUFACTURER.
C. REINFORCING STEEL SHALL BE ASTM A615 GRADE 60 UNLESS NOTED
OTHERWISE. PROVIDE ASTM A706 GRADE 60 BARS FOR WELDED
REINFORCEMENT.
D. LAP REINFORCING SPLICES #6 AND SMALLER BARS - 57 BAR
DIAMETERS WITH 24" MINIMUM UNLESS NOTED OTHERWISE.
E. PROVIDE CORNER BARS WITH 30 BAR DIAMETER LAP TO MATCH
HORIZONTAL
REINFORCEMENT AT ALL GRADE BEAM AND WALL INTERSECTIONS.
2'-0" LAP MINIMUM.
F. ALL REINFORCEMENT SHALL BE DETAILED IN ACCORDANCE WITH THE
LATEST ACI DETAILING MANUAL.
G. CONTRACTOR SHALL COORDINATE ALL PENETRATIONS, CONDUIT,
CHAMFERS AND EMBEDDED ITEMS PRIOR TO CONCRETE PLACEMENT.
H. SET ANCHOR RODS TO HAVE AT LEAST 3" CONCRETE COVER AND TO
ALLOW REINFORCEMENT TO PASS OUTSIDE OF RODS.
FOUNDATION PLAN NOTES:
1. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL
DIMENSIONS AND ELEVATIONS PRIOR TO BEGINNING CONSTRUCTION.
2. REFER TO SHEET S1.1 FOR DETAILS NOT NOTED ON PLAN.
3. FLOOR SLAB SHALL BE 5" THICK CONCRETE REINFORCED WITH #3 @ 14"
O.C.B.W. CENTERED IN SLAB.
4. PROVIDE 2#4x4'-0" DOWELS CENTERED IN SLAB AT ALL INTERIOR CORNERS
5. FINISH FLOOR = DATUM ELEVATION 100'-0", ACTUAL = REFER TO CIVIL
6. REFER TO ARCHITECTURAL FOR LOCATION AND EXTENT OF ALL LEDGES,
POCKETS OR DEPRESSIONS.
7. UNLESS OTHERWISE NOTED ON PLAN, EXTERIOR WALL & LOAD BEARING
WALL STUDS SHALL BE 2X SOUTHERN PINE NO.2 @ 16"O.C. U.N.O.
8. ALL VERTICAL SUPPORTS UNDER BEAMS SHALL BE 4-2X6 U.N.O.
FOUNDATION PLAN
S1.0
PRIVATE
RESIDENCE
2803 HIGHCREST DR.
GRAPEVINE, TX
REVISION
06-18-25
GPEC
LLC
GRAND PYRAMID ENGINEERING
CONSULTANTS, LLC
REGISTRATION#F-24236 (TEXAS)
729 CREEKVIEW LN.
COLLEYVILLE, TX 76034
P:(214)574-0911
GPEC
L
L
C
.
C
O
M
-ADDITION-
843210
SCALE: 1/4" = 1'-0"
FOUNDATION PLAN1
S1.0
5"
DETAIL1
12"
112"
512"
DOWEL "A"
SLAB REINF. REFER
TO PLAN NOTES.
GRADE BEAM REINF.:
(3) #4 TOP CONT.
(3) #4 BOTTOM CONT.
T.O.C. EL.
PERIMETER BEAM WITH LEDGE
SCALE: 3/4"=1'-0"
3'
-
0
"
DETAIL4
SCALE: 3/4"=1'-0"
INTERIOR GRADE BEAM
2x WALL REFER
TO PLAN NOTES
2x PRESSURE TREATED SILL PLATE
WITH 5/8"Øx10" J BOLT @ 4'-0" O.C. &
12" FROM ENDS OF WALL AND DOOR
AND WINDOW OPENINGS. AT SHEAR
WALLS REFER TO SCHEDULE FOR
BOLT SIZE AND SPACING.
T.O.C. EL.
DETAIL10
1-#5 x 2'-6"
Bott., Typ.
TYPICAL BEAM REBAR
GRADE BEAM CORNER REINFORCING
DOWEL SCHEDULE
MARK SIZE
VERT.
LENGTH
HORIZ.
LENGTH SPACING
A #3 2'-0"2'-0"16" O.C.
RE
F
E
R
T
O
1
/
S
1
.
1
5"
DOWEL "A"
3"
C
L
R
.
2'-6"
3"
C
L
R
.
ALTERNATE
HOOKS
REFER
TO 1/S1.1
EXISTING STRUCTURENEW CONSTRUCTION
SLAB REINF.
REFER PLAN NOTES
REFER TO
S1.1
RE
F
E
R
T
O
1
/
S
1
.
1
GRADE BEAM REINF.:
REFER TO 1/S1.1
DETAIL8
SCALE: 3/4"=1'-0"
PERIMETER BEAM CONNECTION DETAIL
CHIP AWAY UPPER EDGE OF
EXISTING FOUNDATION IF
EXISTING BRICK LEDGE AT
JOINT LOCATION.
#4 @ 16" O.C.
MID-HEIGHT OF BEAM
BEND AS SHOWN
8"
#4 X 2'-6" @ 16" O.C. BEND DOWELS AS
REQ'D. WHILE CEMENT IS STILL WET.
DETAIL3
SCALE: 3/4"=1'-0"
PERIMETER BEAM AT PATIO/PORCH
DOWEL "A"
SLAB REINF. REFER
TO PLAN NOTES
5"
3"
C
L
R
.
RE
F
E
R
T
O
1
/
S
1
.
1
REFER
TO 1/S1.1
GRADE BEAM REINF.:
REFER TO 1/S1.1
4"
-
1
2
"
M
A
X
24" W/ 1" TO 4" DROP
36" W/ 5" TO 8" DROP
48" W/ 9" TO 12" DROP
1'-0"
VA
R
I
E
S
(BEAM ONLY WHERESHOWN ON PLAN)
DETAIL7
SCALE: 3/4"=1'-0"
DROP IN SLAB
12
"
M
A
X
RE
F
E
R
T
O
PL
A
N
S
REFER TO 1/S1.1 FORREINFORCEMENT NOTSHOWN
5"
DETAIL2
DOWEL "A"
SLAB REINF. REFER
TO PLAN NOTES.
T.O.C. EL.
PERIMETER BEAM AT PATIO/PORCH
SCALE: 3/4"=1'-0"
RE
F
E
R
T
O
1
/
S
1
.
1
5"
3"
C
L
R
.
GRADE BEAM REINF.:
REFER TO 1/S1.1
REFER
TO 1/S1.1
4"
-
1
2
"
M
A
X
GRADE BEAM REINF.:
REFER TO 1/S1.1
EXISTING STRUCTURE NEW CONSTRUCTION
SLAB REINF.
REFER PLAN NOTES
1/
S
1
.
1
F
I
E
L
D
V
E
R
I
F
Y
REFER
1/S1.1
RE
F
E
R
1/
S
1
.
1
GRADE BEAM REINF.:
REFER TO 1/S1.1
DETAIL9
SCALE: 3/4"=1'-0"
PERIMETER BEAM CONNECTION DETAIL
2-#4 @ 16" O.C.
MID-HEIGHT OF BEAM
BEND AS SHOWN
DRILL 3/4"Ø HOLES ON SLIGHT SLANT. BLOW
HOLES CLEAN WITH COMPRESSED AIR.
SCRAPE HOLES WITH HARD TOOL AND ROUND
WIRE BRUSH TO REMOVE DRILL DUST. BLOW
HOLES CLEAN AGAIN. IT IS CRITICAL THAT
HOLES BE THOROUGHLY CLEANED PRIOR TO
PLACEMENT OF EPOXY. EPOXY SHALL HAVE
MIN. 3000 PSI. BOND STRENGTH.
8"
#4 X 2'-6" @ 16" O.C. BEND DOWELS AS
REQ'D. WHILE CEMENT IS STILL WET.
RE
F
E
R
T
O
PL
A
N
PRIVATE
RESIDENCE
2803 HIGHCREST DR.
GRAPEVINE, TX
REVISION
06-18-25
GPEC
LLC
GRAND PYRAMID ENGINEERING
CONSULTANTS, LLC
REGISTRATION#F-24236 (TEXAS)
729 CREEKVIEW LN.
COLLEYVILLE, TX 76034
P:(214)574-0911
GPEC
L
L
C
.
C
O
M
-ADDITION-
S1.1
FOUNDATION DETAILS
UPUP
C.S.
C.
S
.
C.S.
C.S.
C.S.
C.S.
C.S.
C.S.C.S.
C.
S
.
C.
S
.
C.
S
.
HDU4
HDU4
HDU4
HDU4
EXISTING STRUCTURE
EXISTING STRUCTURE
EXISTING STRUCTURE
SCALE: 3/16" = 1'-0"
0 2 4 6 8 16
1ST FLOOR SHEARWALL PLAN1
S1.2
S1.2
1ST FLOOR
SHEARWALL PLAN
THE EXTERIOR WALLS SHALL BE CONTINUOUSLY SHEATHED WITH 3/8 APA RATED WITH MIN. 6D NAILS AT 6 EDGE/12 FIELD
THIS PLAN WAS DESIGNED BASED ON A WINDSPEED OF:
115 MPH (Vult)
90 MPH EXPOSURE: B(Vasd)
REFER TO S0.1 FOR HOLD DOWN SECTIONS
PRIVATE
RESIDENCE
2803 HIGHCREST DR.
GRAPEVINE, TX
REVISION
06-18-25
GPEC
LLC
GRAND PYRAMID ENGINEERING
CONSULTANTS, LLC
REGISTRATION#F-24236 (TEXAS)
729 CREEKVIEW LN.
COLLEYVILLE, TX 76034
P:(214)574-0911
GPEC
L
L
C
.
C
O
M
-ADDITION-
DN
C.S.
C.S.
C.S.
C.S.
C.
S
.
C.S.
C.
S
.
C.
S
.
SIMPSON MSTC66
STRAP
SIMPSON MSTC66
STRAP
SIMPSON MSTC66
STRAP
SIMPSON MSTC66
STRAP
SIMPSON MSTC66
STRAP
EXISTING STRUCTURE
S1.3
2ND FLOOR
SHEARWALL PLAN
THE EXTERIOR WALLS SHALL BE CONTINUOUSLY SHEATHED WITH 3/8 APA RATED WITH MIN. 6D NAILS AT 6 EDGE/12 FIELD
THIS PLAN WAS DESIGNED BASED ON A WINDSPEED OF:
115 MPH (Vult)
90 MPH EXPOSURE: B(Vasd)
PRIVATE
RESIDENCE
2803 HIGHCREST DR.
GRAPEVINE, TX
REVISION
06-18-25
GPEC
LLC
GRAND PYRAMID ENGINEERING
CONSULTANTS, LLC
REGISTRATION#F-24236 (TEXAS)
729 CREEKVIEW LN.
COLLEYVILLE, TX 76034
P:(214)574-0911
GPEC
L
L
C
.
C
O
M
-ADDITION-
843210
SCALE: 1/4" = 1'-0"
2ND FLOOR SHEARWALL PLAN1
S1.3
REFER TO S0.1 FOR STRAP SECTIONS
DN
3
THIS PLAN WAS DESIGNED BASED ON A WINDSPEED OF:
115 MPH (Vult)
90 MPH EXPOSURE: B(Vasd)
THE WINDSPEED IN GENERAL NOTES AND TABLES ON
S-000 SHEETS IS BASED ON Vasd
ALL JOIST SHALL BE SYP #2 GRADE 2X6 SYP @ 24"O.C. U.N.O.
ALL LOOSE LINTELS SHALL NOT BE FASTENED INTO HEADERS U.N.O
ALL VERTICAL SUPPORT UNDER BEAMS SHALL BE 4-2X U.N.O.
ALL VERTICAL SUPPORTS UNDER MANUFACTURED BEAMS SHALL BE 4-2X U.N.O.
ALL INTERIOR HEADERS SHALL BE BUILT UP W/ 2X6 SYP NO. 2 U.N.O.
ALL EXTERIOR HEADERS SHALL BE BUILT UP W/ 2X8 SYP NO. 2 U.N.O.
ALL LVL LUMBER MECHANICAL PROPERTIES AS FOLLOWS: Fb=2600PSI, Fv=285 PSI AND E=2000KSI
ALL GABLE WALLS AND RAKED WALLS THAT DO NOT HAVE A CEILING ARE TO BE CONTINUOUS FROM
BOTTOM PLATE TO TOP PLATE.
UP
GIRDER TRUSS
GI
R
D
E
R
T
R
U
S
S
G.
T
.
16" FLOOR TRUSSES @ 16"O.C.
ALL HEADERS UNDER FLOOR
SYSTEM ARE PER FLOOR
SYSTEM MANUFACTURER
16" FLOOR TRUSSES @ 16"O.C.
16
"
F
L
O
O
R
T
R
U
S
S
E
S
@
1
6
"
O
.
C
.
14" FLOOR TRUSSES @ 16"O.C.
TRUSS MANUFACTURER TO
ACCOMMODATE 2" GYPCRETE
IN THIS AREA
EXISTING 2ND FLOOR
SYSTEM
EXISTING 2ND FLOOR
SYSTEM
EXISTING 2ND FLOOR
SYSTEM
PRESSURE TREATED
2x12'S @ 24"O.C.
OPEN TO ABOVE
(2)1.75x11.25 LVL 2.0E
CONNECT BEAM TO POST W/
SIMPSON HUCQ412-SDS
CONNECT BEAM TO POST W/
SIMPSON HUCQ210-SDS P.
T
.
(
2
)
2
x
1
2
CON
T
I
N
U
O
U
S
SYP
#
2
6
X
6
P
O
S
T
CO
N
T
I
N
U
O
U
S
SYP
#
2
6
X
6
P
O
S
T
STRAP BEAM HEADER TO
STUD PACK BELOW W/
2-CS16 STRAPS
BEAM PER
MANUFACTURER
BE
A
M
P
E
R
MA
N
U
F
A
C
T
U
R
E
R
S1.4
1ST FLOOR CEILING & 2ND
FLOOR FRAMING PLAN
PRIVATE
RESIDENCE
2803 HIGHCREST DR.
GRAPEVINE, TX
REVISION
06-18-25
GPEC
LLC
GRAND PYRAMID ENGINEERING
CONSULTANTS, LLC
REGISTRATION#F-24236 (TEXAS)
729 CREEKVIEW LN.
COLLEYVILLE, TX 76034
P:(214)574-0911
GPEC
L
L
C
.
C
O
M
-ADDITION-
843210
SCALE: 1/4" = 1'-0"
1st FLOOR CEILING/ 2ND FLOOR FRAMING PLAN1
S1.4
THIS PLAN WAS DESIGNED BASED ON A WINDSPEED OF:
115 MPH (Vult)
90 MPH EXPOSURE: B(Vasd)
THE WINDSPEED IN GENERAL NOTES AND TABLES ON
S-000 SHEETS IS BASED ON Vasd
ALL JOIST SHALL BE SYP #2 GRADE 2X6 SYP @ 24"O.C. U.N.O.
ALL LOOSE LINTELS SHALL NOT BE FASTENED INTO HEADERS U.N.O
ALL VERTICAL SUPPORT UNDER BEAMS SHALL BE 4-2X U.N.O.
ALL VERTICAL SUPPORTS UNDER MANUFACTURED BEAMS SHALL BE 4-2X U.N.O.
ALL INTERIOR HEADERS SHALL BE BUILT UP W/ 2X6 SYP NO. 2 U.N.O.
ALL EXTERIOR HEADERS SHALL BE BUILT UP W/ 2X8 SYP NO. 2 U.N.O.
ALL LVL LUMBER MECHANICAL PROPERTIES AS FOLLOWS: Fb=2600PSI, Fv=285 PSI AND E=2000KSI
ALL GABLE WALLS AND RAKED WALLS THAT DO NOT HAVE A CEILING ARE TO BE CONTINUOUS FROM
BOTTOM PLATE TO TOP PLATE.
* THIS DESIGN ASSUMES NO ATTIC STORAGE WITH 5/10 LOADING U.N.O.
DN
RAFTERS SUPPORTED BY
EXISTING BEAM BELOW
2x8 LEDGER, ATTACH
LEDGER TO EA. STUD W/
5-10d NAILS AT EA STUD
SLOPED
CEILING
SKYLIGHT
SLOPED CEILING JOIST
(2)1.75x11.87 LVL 2.0E
2-2x12
2-
2
x
1
2
SK
Y
L
I
G
H
T
SK
Y
L
I
G
H
T
2-
2
x
1
2
2-
2
x
1
2
2-2x12
2-
2
x
1
2
SIMPSON HUS210-2
AT EA. END, TYP.
SIMPSON HUS210-2
AT EA. END, TYP.
2-2x12
CONNECT BEAM TO POST
W/ SIMPSON LCE4 AT
EACH FACE
CO
N
T
I
N
U
O
U
S
SY
P
#
2
6
X
6
P
O
S
T
CONNECT BEAM TO
POST W/ SIMPSON
LCE4 AT EACH FACE
STRAP BEAM HEADER TO
STUD PACK BELOW W/
2-CS16 STRAPS
DEMO
DEMO
CO
N
T
I
N
U
O
U
S
SY
P
#
2
6
X
6
P
O
S
T
2-2x10
EXISTING STRUCTURE
EXISTING STRUCTURE EXISTING STRUCTURE
S1.5
2ND FLOOR CEILING
FRAMING PLAN
PRIVATE
RESIDENCE
2803 HIGHCREST DR.
GRAPEVINE, TX
REVISION
06-18-25
GPEC
LLC
GRAND PYRAMID ENGINEERING
CONSULTANTS, LLC
REGISTRATION#F-24236 (TEXAS)
729 CREEKVIEW LN.
COLLEYVILLE, TX 76034
P:(214)574-0911
GPEC
L
L
C
.
C
O
M
-ADDITION-
843210
SCALE: 1/4" = 1'-0"
2ND FLOOR CEILING FRAMING PLAN3
S1.5
DN
ALL RAFTERS SHALL BE #2 GRADE SYP 2X6'S @ 24"O.C. U.N.O.
ALL HIPS AND VALLEYS SHALL BE #2 GRADE SYP 2X8 U.N.O.
ALL RIDGES SHALL BE #2 GRADE SYP 2X8 U.N.O.
ALL PURLIN AND T-BRACES SHALL BE #2 GRADE SYP 2X6 WITH
SUPPLEMENTAL BRACE IN WEAK DIRECTION @ 4'O.C. VERTICALLY
ALL VERTICAL SUPPORT UNDER BEAMS SHALL BE 4-2X U.N.O. ALL
VERTICAL SUPPORTS UNDER
ALL LVL LUMBER MECHANICAL PROPERTIES AS FOLLOWS:
FB=2600PSI, FV=285 PSI AND E=2000KSI
SPLICES SHALL OCCUR OVER SUPPORTS AND HAVE A 2'-0"
OVERLAP AT EACH SIDE OF SUPPORT.
PURLIN
PU
R
L
I
N
PU
R
L
I
N
S.L.S.L.
SK
Y
L
I
G
H
T
SK
Y
L
I
G
H
T
EXISTING
ROOF
RAFTERS SUPPORTED
BY BEAM BELOW
RAFTERS SUPPORTED
BY WALL & BEAM BELOW
PRIVATE
RESIDENCE
2803 HIGHCREST DR.
GRAPEVINE, TX
REVISION
06-18-25
GPEC
LLC
GRAND PYRAMID ENGINEERING
CONSULTANTS, LLC
REGISTRATION#F-24236 (TEXAS)
729 CREEKVIEW LN.
COLLEYVILLE, TX 76034
P:(214)574-0911
GPEC
L
L
C
.
C
O
M
-ADDITION-
843210
SCALE: 1/4" = 1'-0"
ROOF FRAMING PLAN1
S1.6
S1.6
ROOF FRAMING
PLAN
SD
SD
SD
SD
SD
NEW CONCRETE DRIVE - SAWCUT EXISTING DRIVE
AND DEMOLISH. PREP SURFACE OF EXISTING DRIVE
FOR NEW CONCRETE
EXISTING DRIVE TO REMAIN
A1.1
2
EXISTING GRAVEL PATH
EXISTING STONE BORDER
16' - 9"
18
'
-
0
1
/
2
"
ALIGN
1' - 6"
3'
-
0
"
±
P
L
A
N
T
E
R
STONE PLANTER WALL
PROVIDE WEEP
HOLES AT 24" OC
BRACING WALL
CONNECTED TO BOTH
SIDES OF PLANTER AT 36"
OC
COMPACTED SUBGRADE
3,000 PSI CONCRETE WITH #
3 BARS O.C.E.W.
6" BASE COMPACTED TO
95% STANDARD PROCTOR
DENSITY
STONE PERIMETER - STONE
TO MATCH EXISTING
REF PLAN
2" COMPACTED
CONCRETE SETTING
SAND
FLAGSTONE WITH
POLYMER SAND
SWEPT INTO JOINTS
EXISTING
STONE AND
GRAVEL
PATH
EXISTING
STONE PATH
BOARDER
STONE BORDER TO
MATCH EXISTING
36" TALL STONE
PLANTER
FLAGSTONE PATIO
3
A1.1
8'
-
2
1
/
4
"
6' - 4 1/4"
*FINAL SIZE AND SHAPE OF PATIO AND PLANTER TO BE
COORDINATED WITH OWNER PRIOR TO CONSTRUCTION.
6" 3,600 PSI CONCRETE WITH
#3 BARS AT 18" O.C.E.W.
6" BASE COMPACTED TO
95% STANDARD PROCTOR
DENSITY
T/
2
Scale
Date
As indicated
A1.1
ARCHITECTURAL
SITE PLAN
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
1/8" = 1'-0"1 ARCHITECTURAL SITE PLAN
3/4" = 1'-0"3 Section Detail - PLANTER
3/8" = 1'-0"2 GARDEN SEATING AREA
3/4" = 1'-0"4 Section Detail - TYPICAL PAVING
1.
2.
3.
4.
GENERAL NOTES
CONTRACTOR SAW CUT EXISTING DRIVE PRIOR TO
DEMOLITION. PROVIDE SMOOTH CONCRETE FACE FOR
EXPANSION TO NEW CONCRETE. DOWEL EXISTING
CONCRETE INTO NEW CONCRETE. FILL JOINT WITH
JOINT SEALANT.
CONTRACTOR TO HAUL AWAY ALL DEMOLISHED
CONCRETE.
STONE THAT MUST BE REMOVED PRIOR TO NEW WORK
SHALL BE RETURNED TO THE OWNER. THE OWNER HAS
THE RIGHT OF REFUSAL. IF THE OWNER REFUSES THE
STONE THE CONTRACTOR SHALL DISPOSE OF THE
STONE.
CONTRACTOR TO REWORK SPRINKLER SYSTEM IF
REQUIRED.
No. Description Date
06/18/2025
DEMOLISH EXISTING WOOD DECK
DEMOLISH EXISTING POST AND RAILS
DEMOLISH SLAB AND PREP
SURFACE FOR NEW SLAB - REF
STRUCTURAL
REMOVE BRICK AND SHEATHING FROM
EXISTING WALL AND PREP SURFACE FOR
NEW FINISH
DEMOLISH EXISTING POST AND RAILS
REMOVE BRICK AND SHEATHING FROM
EXISTING WALL AND PREP SURFACE FOR
NEW FINISH
REMOVE BRICK AND SHEATHING FROM
EXISTING WALL AND PREP SURFACE FOR
NEW FINISH
DEMOLISH EXISTING DOOR
DEMOLISH EXISTING WINDOW
DEMOLISH EXISTING WALL AND
PREP SURFACE FOR NEW FINISH
STUDY
103
CLST
102
CLST
105
PORCH
101
ENTRY
104
BATHROOM
107
LIVING
108
PANTRY
110
DEN
109
LAUNDRY
106
KITCHEN
112
DINING
111
BREAKFAST
113
PATIO
114
GARAGE
118
*SHORE EXISTING WALLS PRIOR TO
DEMOLITION - REFERENCE
STRUCTURAL
DEMOLISH EXISTING STAIRS
Scale
Date
1/4" = 1'-0"
A1.2
GROUND LEVEL -
DEMOLITION
PLAN
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
1/4" = 1'-0"1 GROUND LEVEL - DEMOLITION PLAN
No. Description Date
06/18/2025
DEMOLISH ROOF
DEMOLISH RAIL AND DECK
DEMOLISH DOOR
DEMOLISH
DOOR AND
PREP OPENING
FOR NEW DOOR
PREPARE OPENING
IN EXISTING WALL
FOR NEW WINDOW
PER PLANS
DEMOLISH WALL
DEMOLISH WALL
DEMOLISH WALL
DEMOLISH WINDOW
DEMOLISH ROOF
CLST
204
HVAC
202
WATER HEATER
203
WC
205
LOFT
206
SHOWER
207
BATH
208
BEDROOM
212
BATH
211
CLST
210
BEDROOM
209
MASTER
BEDROOM
201
DEMOLISH EXISTING
FLOOR ASSEMBLY
Scale
Date
1/4" = 1'-0"
A1.3
SECOND LEVEL -
DEMOLITION
PLAN
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
1/4" = 1'-0"1 SECOND LEVEL - DEMOLITION PLAN
No. Description Date
06/18/2025
UP
2
1
A4.1
____
1
A4.2
____
4
A4.2
____
2
A4.1
____
1'
-
6
"
2'
-
0
"
14
'
-
0
"
15
'
-
8
"
3'
-
4
"
2' - 0"2' - 0" 4' - 8" 2' - 0"26' - 11"
3'
-
6
"
3'
-
4
"
7'
-
2
"
5' - 10"3' - 4"5' - 11 1/2" 2' - 2 1/2"
EQ
EQ
EQ EQ
E
Q
E
Q
2' - 11"3' - 4"3' - 4"
2' - 0"9' - 9"1' - 0"
12' - 9"
35
'
-
0
"
37' - 7"
LIVING
108
DINING
111
KITCHEN
112
BREAKFAST
113
PANTRY
110
DEN
109
LAUNDRY
106
STUDY
103
PATIO
115
SUN ROOM
120
STORAGE
119
CARPORT
121
GARAGE
118
ENTRY
104
BATHROOM
107
PATIO
114TORNADO SHELTER FINAL SIZE
AND LOCATION BY
MANUFACTURER
BASIS OF DESIGN: LONE STAR
SAFE ROOMS
PORCH
101
CLST
102
CLST
105
MUD ROOM
116
EXISTING FRIDGE
1
A4.3
2
A4.3
TANKLESS WATER HEATER
1
A5.1
2
A5.1
3
A5.1
104
101
102
103
AA
AA
B
A
B
A
A
4
A5.1
TILE
FLOORING
TILE
FLOORING
ALIGN HVAC
122 122
3
A4.3
1'
-
6
"
1' - 3"
7' - 10 3/4"4' - 0"
HVAC UNIT
STAMP AND STAIN CONCRETE DECK
REPLACE EXISTING SINK SUPPLY
LINES AND INSULATION
RE
F
S
C
H
E
D
U
L
E
REF SCHEDULE
RE
F
S
C
H
E
D
U
L
E
REF SCHEDULE
DOOR TYPES TYPE 1 TYPE 2
6 PANEL DOOR FULL LITE DOOR
RE
F
S
C
H
E
D
U
L
E
REF SCHEDULE
TYPE 3
MURPHY DOOR
PREMANUFACTURED
DOOR
BASIS OF DESIGN:
MURPHYDOOR.COM
Scale
Date
As indicated
A2.1
GROUND LEVEL -
FLOOR PLAN
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
1/4" = 1'-0"1 GROUND LEVEL - FLOOR PLAN
Door Schedule
Door
Number
Door
Type Door Size
Finish
Comments
101 1 32" x 84"
102 1 32" x 84"
103 1 32" x 84"
104 2 32" x 84"
122 1 32" x 84"
201 1 32" x 84"
202 1 32" x 84"
203 3 34" x 84"
204 3 34" x 84"
205 1 34" x 84" SOLID CORE WOOD
DOOR, DOOR SEAL
KIT
(ACOUSTICGEOMETRY
.COM)
206 1 32" x 84"
207 1 32" x 84"
208 1 32" x 84"
209 1 32" x 84"
210 2 32" x 84"
1.
2.
3.
4.
GENERAL NOTES:
ALL INTERIOR WALLS ARE TYPE A UNLESS
NOTED OTHERWISE.
DIMENSIONS ARE FROM FACE OF STUD UNLESS
NOTED OTHERWISE.
CONTRACTOR TO REMOVE ALL EXISTING ATTIC
INSULATION. PATCH AND FILL ANY HOLES AND
REPLACE SEALANT AS NEEDED. PREPARE ATTIC
TO RECEIVE NEW INSULATION.
ALL SLAB ON GRADE SHALL BE FLOOR
ASSEMBLY #1 U.N.O.
PARTITION TYPES
PARTITION TYPE A
1. 1/2" GYPSUM BOARD
2. 2x4 WOOD STUD
3. 1/2" GYPSUM BOARD
PARTITION TYPE B
1. 1/2" GYPSUM BOARD
2. 2x4 WOOD STUD
3. SOUND ATTENUATION BATTS
4. 1/2" GYPSUM BOARD
PARTITION TYPE C
1. 2 LAYERS: 5/8" GYPSUM SOUNDBREAK XP
2. 7/8" HAT CHANNEL ON NEOPRENE ISOLATION PADS
3. 2"x4" WOOD STUD
4. 3" ROCKWOOL SAFE 'N' SOUND
5. 1/2" AIR GAP
6. 5/8" GYPSUM SOUNDBREAK XP
7. 2"x4" WOOD STUD
8. 3" ROCKWOOL SAFE 'N' SOUND
9. 1/2" GYPSUM BOARD
No. Description Date
06/18/2025
DN
1
A4.1
____
1
A4.2
____
4
A4.2
____
2
A4.1
____
BEDROOM
209
BEDROOM
212
BATH
208
MASTER
BEDROOM
201
CLST
204
LOFT
206
BATH
211
WORKROOM
215
MUSIC ROOM
216
CLST
217
BEDROOM
219
BATHROOM
220
ALL WALLS, CEILING, AND FLOOR IN ROOM TO HAVE
ACOUSTICAL TREATMENT. PROVIDE ACOUSTIC
FLOORING UNDERLAY (ACOUSTICGEOMETRY.COM)
HORIZONTAL ASSEMBLIES TO BE FLOOR ASSEMBLY #
3 AND CEILING ASSEMBLY #2. ALL WALLS TO BE
SIMILAR TO WALLS DETAILED IN 4/A5.1
OP
E
N
T
O
LI
V
I
N
G
NEW WINDOW
17
'
-
4
"
10
'
-
3
1
/
2
"
BENCH
2' - 0"2' - 0" 4' - 8" 2' - 0"15' - 3"11' - 8"
EQ EQ
E
Q
E
Q
EQ
EQ
2'
-
0
"
3'
-
6
"
13
'
-
0
"
7'
-
9
"
8'
-
9
"
35
'
-
0
"
1'
-
6
"
4'
-
6
"
37' - 7"
12' - 0 3/4"4' - 8 1/2"4' - 6"12' - 2 1/4"3' - 4 1/2"0' - 9 1/4"
WATER HEATER
203
HVAC
202
WC
205
SHOWER
207
CLST
210
DECK
213
CLST
214
HVAC
218
WC
216
REVISE ROOF SLOPE
35' - 5"
4' - 11"3' - 4"24' - 2"3' - 0"
0' - 9 1/4"9' - 9 1/2"0' - 4 1/2"12' - 1 1/2"6' - 4 1/2"5' - 11 3/4"
1'
-
6
"
20
'
-
0
"
6'
-
6
1
/
2
"
6'
-
5
1
/
2
"
1
A4.3
2
A4.3
A6.1 35
A6.1
7
2
4
A6.1 810
9
6
209 208
207
206
203
204
210
201
202
1
A5.1
2
A5.1
3
A5.1
0' - 0 1/2"
0'
-
0
1
/
2
"
0' - 0 1/2"
205
A A
C
C
A
A
A
B
A
B
A A
A A
A7.2
3
4
A5.1
WOOD GUARD
WOOD HANDRAIL -
REVISE AS NEEDED
TILE
FLOORING
CARPET
FLOORING
WOOD
LAMINATE
FLOORING
SCHLUTER DITRA
CONTINUOUS THROUGHOUT
AREAS WITH TILE ON SECOND
LEVEL
3
9' - 3 1/2"
3
A4.3
2'
-
0
"
B
B
B
B
C
C
C
CC
C
STAMP AND STAIN CONCRETE DECK
WOOD
LAMINATE
FLOORING
WOOD
LAMINATE
FLOORING
WOOD
LAMINATE
FLOORING
ROBE HOOKS
3' - 0"
WINDOW TYPES TYPE A TYPE B
1'
-
0
"
6'
-
0
"
2' - 0"
1'
-
0
"
6'
-
0
"
3' - 0"
TYPE C
3'
-
0
"
4'
-
0
"
TYPE D
2' - 0"
4'
-
0
"
SKYLIGHT WITH
INTEGRAL
POWERED SHADE
TYPE E
10" TUBULAR
SKYLIGHT
Scale
Date
As indicated
A2.2
SECOND LEVEL -
FLOOR PLAN
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
1/4" = 1'-0"2 SECOND LEVEL - FLOOR PLAN
1.
2.
3.
4.
5.
GENERAL NOTES:
ALL INTERIOR WALLS ARE TYPE A UNLESS
NOTED OTHERWISE.
DIMENSIONS ARE FROM FACE OF STUD UNLESS
NOTED OTHERWISE.
CONTRACTOR TO REMOVE ALL EXISTING ATTIC
INSULATION. PATCH AND FILL ANY HOLES AND
REPLACE SEALANT AS NEEDED. PREPARE ATTIC
TO RECEIVE NEW INSULATION.
CONTRACTOR TO PROVIDE BLOCKING FOR
TOILET ACCESSORIES.
ALL SECOND LEVEL FLOOR ASSEMBLIES SHALL
BE FLOOR ASSEMBLY #2 U.N.O.
No. Description Date
06/18/2025
1
A4.1
____
1
A4.2
____
4
A4.2
____
2
A4.1
____
1
A4.3
2
A4.3
WINDOW TYPE E
WINDOW TYPE D
WINDOW TYPE D
EXISTING ROOF
2
8
8 8
1
A5.1
2
A5.1
3
A5.1
POWERED
ATTIC EXHAUST
FAN
POWERED
ATTIC EXHAUST
FAN
A7.3
1
1/4" = 1'-0"1 Roof Plan Scale
Date
1/4" = 1'-0"
A2.3
ROOF PLAN
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
1.
2.
3.
4.
5.
GENERAL NOTES:
CONTRACTOR TO REMOVE EXISTING ROOF SHINGLES
AND UNDERLAYMENT.
PROVIDE NEW SELF-ADHERED ROOFING
UNDERLAYMENT CONTINUOUS OVER ROOF DECK.
BASIS OF DESIGN: GRACE VYCOR SELECT
PROVIDE POLYMER MODIFIED HIGH IMPACT RATED
ASPHALT SHINGLE CONTINUOUS OVER ROOF DECK.
CONTRACTOR TO PROVIDE A MINIMUM OF 7.5 SF OF
ATTIC VENTILATION.
PROVIDE GUTTER CONTINUOUS AROUND ROOF.
PROFILE TO MATCH EXISTING.
No. Description Date
06/18/2025
SD
SD
STUDY
103
CLST
102
CLST
105
PORCH
101
DEN
109
BATHROOM
107
LAUNDRY
106
LIVING
108
PANTRY
110
BREAKFAST
113
KITCHEN
112
DINING
111
PATIO
114
MUD ROOM
116
PATIO
115
SUN ROOM
120
STORAGE
119
GARAGE
118CARPORT
121
3' - 0"6' - 4 1/2"3' - 0"
EQ
EQ
EQ EQ
PAINTED WOOD
PLANK SOFFIT
PAINTED WOOD
PLANK SOFFIT
EQ
EQ
3' - 0"6' - 6 3/4"3' - 0"
EQ
EQ
2' - 0 3/4"3' - 5"3' - 5"2' - 0 3/4"
CROWN
MOLDING
1/4" = 1'-0"1
GROUND LEVEL - REFLECTED CEILING
PLAN Scale
Date
1/4" = 1'-0"
A3.1
GROUND LEVEL -
REFLECTED
CEILING PLAN
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
No. Description Date
06/18/2025
SD
SD
SD
TUBULAR SKYLIGHT
CLST
204BATH
208
LOFT
206 HVAC
202
WATER HEATER
203
WC
205
SHOWER
207
BEDROOM
212
BATH
211
CLST
210
BEDROOM
209
DECK
213
WORKROOM
215
MUSIC ROOM
216
WC
216
BATHROOM
220
BEDROOM
219
HVAC
218
CLST
217
CLST
214 MASTER
BEDROOM
201
4.
5
SKY LIGHT SKY LIGHT
1'
-
9
"
3'
-
0
"
5
'
-
2
1
/
4
"
4'
-
8
1
/
4
"
3
'
-
0
"
1
'
-
9
"
2' - 4 1/2"2' - 4"1' - 9"1' - 6"5' - 3 1/2"1' - 6"1' - 9"
EQ
EQ
EQ EQ
EQ
EQ
6' - 2"7' - 0"3' - 0"
3' - 9 1/2"2' - 0"2' - 0"2' - 0"5' - 7 3/4"2' - 0"2' - 0"2' - 0"3' - 9 1/4"
4'
-
2
"
4'
-
7
"
1
'
-
6
1
/
4
"
EQEQ
EQ
PAINTED WOOD SOFFIT TO MATCH EXISTING
CROWN MOLDING - TYPICAL
CROWN MOLDING
CROWN MOLDING
DIMMABLE
LED TAPE
LIGHT
CROWN MOLDING
CROWN MOLDING
11' - 9 1/2"
3'
-
9
"
SMOKE DETECTOR -
TYPICAL
EQEQ
4'
-
0
"
8'
-
1
0
3
/
4
"
4'
-
0
"
2' - 0"4' - 0 1/2"4' - 0 1/2"2' - 0"
6" X 16" SOFFIT VENT - TYPICAL
TRAY CEILING
9'-0"
AFF
8'-0"
AFF
VAULTED CEILING
EQEQEQ
EQ
WATERFALL SHOWER HEAD
EXHAUST FAN AND LIGHT
BULB HEATER FINAL
SELECTION BY OWNER
EXHAUST FAN
Scale
Date
1/4" = 1'-0"
A3.2
SECOND LEVEL -
REFLECTED
CEILING PLAN
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
1/4" = 1'-0"1
SECOND LEVEL - REFLECTED CEILING
PLAN
No. Description Date
06/18/2025
GROUND LEVEL0' - 0"
EXISTING SECOND
LEVEL9' - 0"
2
A4.3
3
A5.1
SECOND LEVEL9' - 4 3/8"
GROUND LEVEL
0' - 0"
EXISTING SECOND
LEVEL9' - 0"
1
A4.3
1
A5.1
2
A5.1
SECOND LEVEL9' - 4 3/8"
Scale
Date
1/4" = 1'-0"
A4.1
EXTERIOR
ELEVATIONS
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
1/4" = 1'-0"1 PLAN EAST ELEVATION
1/4" = 1'-0"2 PLAN SOUTH ELEVATION
EXTERIOR FINISH SCHEDULE:
MODULAR FACE BRICK:
DIMENSIONS: 3 5/8" WIDE X 2 1/4" TALL X 7 5/8" LONG
COLOR: TBD
SHIP LAP WOOD SIDING:
DIMENSIONS: MATCH EXISTING
PAINT: TBD
1.
GENERAL NOTES:
ALL EXISTING WOOD SIDING TO BE PAINTED TO
MATCH NEW SIDING. CONTRACTOR TO REMOVE
ANY CHIPPED OR PEALING PAINT, REPLACE
SEALANT, AND PREP SURFACE FOR NEW
PRIMER AND PAINT.
No. Description Date
06/18/2025
GROUND LEVEL
0' - 0"
EXISTING SECOND
LEVEL9' - 0"
2
A4.33
A5.1
SOLDIER COURSE
WITH EVERY 3RD
COURSE CANTED TO
MATCH EXISTING
TANKLESS HOT WATER HEATER
MODULAR FACE BRICK: 1/4 RUNNING BOND TO MATCH EXISTING
PAINTED WOOD LAP
SIDING TO MATCH
EXISTING
PAINTED STEEL GUARDRAIL
EXISTING BRICK
EXISTING WOOD LAP
SIDING
SECOND LEVEL9' - 4 3/8"
GROUND LEVEL0' - 0"
EXISTING SECOND
LEVEL9' - 0"
1
A4.3
1
A5.1
2
A5.1
SOLDIER COURSE
WITH EVERY 3RD
COURSE CANTED TO
MATCH EXISTING
MODULAR FACE BRICK: 1/4
RUNNING BOND TO MATCH
EXISTING
PAINTED WOOD LAP
SIDING TO MATCH
EXISTING
EXISTING BRICKEXISTING WOOD LAP SIDING
SECOND LEVEL9' - 4 3/8"
0' - 4"
MI
N
I
M
U
M
3'
-
0
"
SPACE PER MANUFACTURER
*FACTORY FINISHED STEEL RAIL
0' - 4"
MI
N
I
M
U
M
3'
-
0
"
SPACE PER MANUFACTURER WOOD HANDRAIL PROFILE: 6210
1"X1" BALUSTER SPACED 4" OC
4"X4" WOOD POST
FINIAL POST CAP: SPADE TOP
* STAINED TO MATCH EXISTING
Scale
Date
As indicated
A4.2
EXTERIOR
ELEVATIONS
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
1/4" = 1'-0"1 PLAN WEST ELEVATION
1/4" = 1'-0"4 PLAN NORTH ELEVATION
3/4" = 1'-0"2 TYPICAL BALCONY GUARDRAIL
3/4" = 1'-0"3 TYPICAL INTERIOR GUARDRAIL
No. Description Date
06/18/2025
GROUND LEVEL0' - 0"
EXISTING SECOND
LEVEL9' - 0"
2
A4.3
WORKROOM
215
CLST
217
GARAGE
118
STORAGE
119
SUN ROOM
120
3
A5.1
A7.2
1
SECOND LEVEL9' - 4 3/8"
GROUND LEVEL
0' - 0"
EXISTING SECOND
LEVEL9' - 0"
1
A4.3
BEDROOM
219
WORKROOM
215
SUN ROOM
120 MUD ROOM
116
A7.2
2
A7.2
2
SECOND LEVEL9' - 4 3/8"
GROUND LEVEL0' - 0"
EXISTING SECOND
LEVEL9' - 0"
SECOND LEVEL
9' - 4 3/8"
FI
E
L
D
V
E
R
I
F
Y
15
E
Q
R
I
S
E
R
S
W
I
T
H
A
M
A
X
I
M
U
M
7
3
/
4
"
R
I
S
E
=
9
'
-
4
1
/
2
"
±
6'
-
8
"
INTERIOR GUARDRAIL
HANDRAIL TO MATCH
GUARDRAIL ON BOTH
SIDES OF STAIRS
STAINED WOOD STAIRS
3'
-
0
"
A7.3
4
A7.3
5
1/4" = 1'-0"1 EAST/WEST BUILDING SECTION
1/4" = 1'-0"2 NORTH/SOUTH BUILDING SECTION
Scale
Date
As indicated
A4.3
BUILDING
SECTIONS
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
3/8" = 1'-0"3 STAIR SECTION
No. Description Date
06/18/2025
GROUND LEVEL0' - 0"
EXISTING SECOND
LEVEL9' - 0"
WALL ASSEMBLY #1
WALL ASSEMBLY #2
BALCONY ASSEMBLY #1
A7.3
2
A7.3
3
SECOND LEVEL9' - 4 3/8"
GROUND LEVEL0' - 0"
EXISTING SECOND
LEVEL9' - 0"
A7.1
7
A7.1
3
A7.1
4
A7.1
1
A7.1
2
SECOND LEVEL
9' - 4 3/8"
GROUND LEVEL0' - 0"
EXISTING SECOND
LEVEL9' - 0"
A7.1
7
SECOND LEVEL9' - 4 3/8"
EXISTING SECOND
LEVEL
9' - 0"
A7.2
4
A7.2
5
SECOND LEVEL
9' - 4 3/8"
Scale
Date
1/2" = 1'-0"
A5.1
WALL SECTIONS
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
1/2" = 1'-0"1 WALL SECTION
1/2" = 1'-0"2 WALL SECTION
1/2" = 1'-0"3 WALL SECTION
1/2" = 1'-0"4 Section 4
WALL ASSEMBLIES
WALL ASSEMBLY #1
1. WOOD LAP SIDING - MATCH EXISTING
2. AIR BARRIER
3. 1/2" EXTERIOR SHEATHING - REF STRUCTURAL
4. WOOD STUD - REF STRUCTURAL
5. BATT INSULATION - R-13
6. 1/2" GYPSUM BOARD
WALL ASSEMBLY#2
1. NOMINAL FACE BRICK - MATCH EXISTING
2. AIR GAP
3. AIR BARRIER
4. 1/2" EXTERIOR SHEATHING - REF STRUCTURAL
5. WOOD STUD - REF STRUCTURAL
6. BATT INSULATION - R-13
7. 1/2" GYPSUM BOARD
CEILING ASSEMBLIES
CEILING ASSEMBLY #1
1. 1/2" GYPSUM BOARD
2. 2x CEILING JOIST - REF STRUCTURAL
3. INSULATION - R-49
EXTERIOR ASSEMBLY #2
1. 2 LAYERS: 5/8" GYPSUM SOUNDBREAK XP
2. 2"x6" CEILING JOISTS
3. 6" ROCKWOOL SAFE 'N' SOUND
4. 1/2" AIR GAP
5. 5/8" GYPSUM SOUNDBREAK XP
6. 2x CEILING JOIST - REF STRUCTURAL
7. INSULATION - R-49
FLOOR ASSEMBLIES
FLOOR ASSEMBLY #1
1. CONCRETE SLAB-ON-GRADE - REF STRUCTURAL
2. UNDERSLAB VAPOR BARRIER
FLOOR ASSEMBLY #2
1. SUB-FLOOR - REF STRUCTURAL
2. JOIST ASSEMBLY - REF STRUCTURAL
3. PROVIDE BATT INSULATION OVER UNCONDITIONED
SPACE
4. 1/2" GYPSUM BOARD - 5/8" TYPE X GYPSUM BOARD
ABOVE GARAGE
FLOOR ASSEMBLY #3
1. 2" GYPCRETE TOPPING SLAB
2. 1/4" MAXXON ACOUSTI-MAT
2. JOIST ASSEMBLY - REF STRUCTURAL
3. 6" ROCKWOOL SAFE 'N' SOUND
4. 5/8" TYPE X GYPSUM BOARD ABOVE GARAGE
BALCONY ASSEMBLIES
BALCONY ASSEMBLY #1
1. 1-1/2" LIGHTWEIGHT CONCRETE TOPPING SLAB
2. 1/4" DRAINAGE MAT
3. 60 MIL SELF ADHERED SHEET WATERPROOFING
4. PLYWOOD SUB-FLOOR - REF STRUCTURAL
5. WOOD FLOOR JOISTS - REF STRUCTURAL
6. SOFFIT PANEL
No. Description Date
06/18/2025
1
A4.3
CLOSET SHELF
AND ROD
4' - 4"3' - 0"
3'
-
6
"
3'
-
6
"
7'
-
0
"
CLOSET SHELF
AND ROD
BUILT IN SHELVES
3' - 0"3' - 0"
7'
-
0
"
HAMPER WITH SHELVES ABOVE
4
A5.1
1
A4.3
CLOSET SHELF
AND ROD
7'
-
0
"
7' - 2 1/4"QUARTZ
COUNTERTOP
CLOSET SHELF
AND ROD
3
A5.1
3/8" MIN GLASS DOOR
AND ENCLOSURE
1' - 9"2' - 6"1' - 9"
6'
-
7
3
/
4
"
SHOWER CURB WITH TILE
ON ALL EXPOSED FACES
2'
-
7
"
2' - 0"2' - 6"1' - 9" 1' - 9"2' - 6"2' - 0"
12' - 6"
LIGHT FIXTURE - SELECTION
BY OWNER
TILE - SELECTION BY OWNER
QUARTZ COUNTERTOP -
SELECTION BY OWNER
MIRROR - SELECTION BY
OWNER
2' - 2 1/2"
BUILT IN BENCH WITH
QUARTZ SURFACE
BUILT IN NICHE
FULL HEIGHT TILE -
SELECTION BY OWNER
1'
-
1
3
/
4
"
2'
-
0
"
1
'
-
0
"
4
A5.1
WATERFALL SHOWER
HEAD CONTROL REFER TO
CEILING PLAN FOR
SHOWER HEAD LOCATION
BUILT IN BENCH WITH
QUARTZ SURFACE
BUILT IN NICHE
FULL HEIGHT TILE -
SELECTION BY
OWNER 1'
-
0
"
2'
-
0
"
1'
-
1
3
/
4
"
3
A7.4
4
A7.4
3' - 0"
BUILT IN BENCH WITH
QUARTZ SURFACE
BUILT IN NICHE
FULL HEIGHT TILE -
SELECTION BY OWNER
1'
-
0
"
2'
-
0
"
1'
-
1
3
/
4
"
Scale
Date
1/2" = 1'-0"
A6.1
INTERIOR
ELEVATIONS
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
1/2" = 1'-0"2 CLOSET - NORTH
1/2" = 1'-0"3 CLOSET - EAST
1/2" = 1'-0"4 CLOSET - SOUTH
1/2" = 1'-0"5 CLOSET - WEST
1/2" = 1'-0"6 BATHROOM - NORTH
1/2" = 1'-0"7 BATHROOM - SOUTH
1/2" = 1'-0"8 SHOWER - EAST
1/2" = 1'-0"9 SHOWER - NORTH
1/2" = 1'-0"10 SHOWER - WEST
No. Description Date
06/18/2025
CAST IN PLACE CONCRETE SLAB -
REFER TO STRUCTURAL
SEALANT CANT
PREFORMED STAINLESS STEEL DRIP
EDGE CONTINUOUS ALONG BRICK
LEDGE SET IN TWO CONTINUOUS BEADS
OF NON CURING BUYTL SEALANT
FLEXIBLE FLASHING - EXTEND TO FACE
OF BRICK
FULL HEAD WEEP VENT AT 24" O.C.
CAVITY DRAINAGE MATERIAL
AIR BARRIER
SILL GASKET
2x PRESSURE TREATED STUD FRAMING
1/2" EXTERIOR SHEATHING - REF
STRUCTURAL
2x WOOD STUD FRAMING - REF
STRUCTURAL
BATT INSULATION AS SCHEDULED
1/2" GYPSUM BOARD
BRICK AS SCHEDULED
TERMINATION BAR WITH CONTINUOUS
SEALANT JOINT
AIR BARRIER
1/2" EXTERIOR SHEATHING - REF
STRUCTURAL
METAL FLASHING WITH HEMMED EDGE
SET IN SEALANT
BATT INSULATION AS SCHEDULED
1/2" GYPSUM BOARD
BRICK AS SCHEDULED
FULL HEAD WEEP VENT AT 24" O.C.
15° SLOPE
FLEXIBLE FLASHING CONTINUOUS
ALONG SILL
WINDOW SILL AS SCHEDULED
BLOCKING AS NEEDED
WOOD STOOL TRIM
SEALANT
SEALANT
MASONRY ROWLOCK SLOPED AT
WINDOW SILL
WINDOW FLANGE SET IN SEALANT.
PROVIDE 2" GAPS AT SILL 12" OC A
MINIMUM OF 4" FROM CORNER
FLEXIBLE FLASHING WRAPPED 6"
MINIMUM UP EACH JAMB
2x WOOD STUD FRAMING - REF
STRUCTURAL
AIR BARRIER
1/2" EXTERIOR SHEATHING - REF
STRUCTURAL
SS FLASHING WITH HEMMED EDGE SET
IN SEALANT
BATT INSULATION AS SCHEDULED
1/2" GYPSUM BOARD
BRICK AS SCHEDULED
FULL HEAD WEEP VENT AT 24" O.C.
FLEXIBLE FLASHING
WINDOW HEAD AS SCHEDULED
2x DOUBLE TOP PLATE - REF
STRUCTURAL
SEALANT
MASONRY SOLDIER COURSE WITH
ALTERNATING SLOPED BRICK - AS SCHEDULED
FLEXIBLE FLASHING
FILL ROUGH OPENING WITH EXPANDING
FOAM SEALANT
SIDING AS SCHEDULED
PAINTED STEEL LOOSE LINTEL - REF
STRUCTURAL
SEALANT
WINDOW FLANGE SET IN SEALANT
CONTINUOUS AROUND HEAD AND JAMB
DRIP EDGE
2x HEADER - REF STRUCTURAL
AIR BARRIER
1/2" EXTERIOR SHEATHING - REF
STRUCTURAL
BATT INSULATION AS SCHEDULED
1/2" GYPSUM BOARD
FLEXIBLE FLASHING CONTINUOUS
ALONG SILL
WINDOW SILL AS SCHEDULED
BLOCKING AS NEEDED
WOOD STOOL TRIM
SEALANT
SEALANT
FLEXIBLE FLASHING WRAPPED 6"
MINIMUM UP EACH JAMB
2x WOOD STUD FRAMING - REF
STRUCTURAL
WINDOW FLANGE SET IN SEALANT.
PROVIDE 2" GAPS AT SILL 12" OC A
MINIMUM OF 4" FROM CORNER
SS METAL DRIP EDGE WITH HEMMED
EDGE SET IN SEALANT
AIR BARRIER
1/2" EXTERIOR SHEATHING - REF
STRUCTURAL
BATT INSULATION AS SCHEDULED
1/2" GYPSUM BOARD
BRICK AS SCHEDULED
SEALANT AND BACKER ROD
SEALANT
WINDOW FLANGE SET IN SEALANT.
PROVIDE 2" GAPS AT SILL 12" OC A
MINIMUM OF 4" FROM CORNER
FLEXIBLE FLASHING WRAPPED 6"
MINIMUM UP EACH JAMB
2x WOOD STUD FRAMING - REF
STRUCTURAL
FILL ROUGH OPENING WITH EXPANDING
FOAM SEALANT
WINDOW JAMB AS SCHEDULED
AIR BARRIER
1/2" EXTERIOR SHEATHING - REF
STRUCTURAL
BATT INSULATION AS SCHEDULED
1/2" GYPSUM BOARD
WOOD SIDING AS SCHEDULED
SEALANT AND BACKER ROD
SEALANT
WINDOW FLANGE SET IN SEALANT.
PROVIDE 2" GAPS AT SILL 12" OC A
MINIMUM OF 4" FROM CORNER
FLASHING TAPE
2x WOOD STUD FRAMING - REF
STRUCTURAL
FILL ROUGH OPENING WITH EXPANDING
FOAM SEALANT
WINDOW JAMB AS SCHEDULED
WINDOW TRIM TO MATCH EXISTING
SOFFIT PANEL
WINDOW HEAD AS SCHEDULED
2x DOUBLE TOP PLATE - REF
STRUCTURAL
GUTTER PROFILE TO MATCH
EXISTING
ASPHALT SHINGLE ROOF TO
MATCH EXISTING
FLASHING TAPE
FILL ROUGH OPENING WITH EXPANDING
FOAM SEALANT
SEALANT
WINDOW FLANGE SET IN SEALANT
CONTINUOUS AROUND HEAD AND JAMB
SHEET APPLIED SELF ADHERING ROOF
UNDERLAYMENT AS SCHEDULED
2x HEADER - REF STRUCTURAL
MATCH EXISTING ELEVATION
MA
T
C
H
E
X
I
S
T
I
N
G
SOFFIT VENT
AIR GAP
Scale
Date
3" = 1'-0"
A7.1
SECTION DETAILS
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
3" = 1'-0"1 Section Detail - BRICK LEDGE
3" = 1'-0"2 Section Detail - WINDOW SILL BRICK
3" = 1'-0"3
Section Detail - WINDOW HEAD/LEVEL
BRICK
3" = 1'-0"4
Section Detail - WINDOW SILL WOOD
SIDING
3" = 1'-0"5 Section Detail - WINDOW JAMB BRICK
3" = 1'-0"6
Section Detail - WINDOW JAMB WOOD
SIDING
3" = 1'-0"7
Section Detail - WINDOW HEAD/ROOF
WOOD SIDING
No. Description Date
06/18/2025
2x DOUBLE BLOCKING
ASPHALT SHINGLE ROOF
SKYLIGHT
SADDLE FLASHING
GYPSUM BOARD
2x DOUBLE BLOCKING
SKYLIGHT
INSULATION AS SCHEDULED
STEP FLASHING
GYPSUM BOARD
0'
-
0
1
/
2
"
GYPSUM SOUNDBREAK XP
2 LAYERS: GYPSUM SOUNDBREAK XP
HAT CHANNEL
NEOPRENE ISOLATION PAD
ROCKWOOL SAFE 'N' SOUND
2X4 STUD WALL ISOLATED FROM
STRUCTURAL PARTITION
3/4" VENEER PLYWOOD PAINTED
DOOR AS SCHEDULED
BOOKCASE DOOR
0'
-
0
1
/
2
"
CEILING JOISTS
FULL FILL INSULATION
GYPSUM SOUNDBREAK XP
2 LAYERS: GYPSUM SOUNDBREAK XP
ACOUSTICAL SEALANT
ACOUSTICAL SEALANT
HAT CHANNEL
NEOPRENE ISOLATION PAD
CEILING JOISTS ISOLATED
FROM CEILING JOISTS
ROCKWOOL SAFE 'N' SOUND
ROCKWOOL SAFE 'N' SOUND
CEILING JOISTS
2X4 STUD WALL ISOLATED FROM
STRUCTURAL PARTITION
0' - 0 1/2" AIR GAP
FLOOR JOISTS
FULL FILL INSULATION
SILL PLATE
GYPSUM SOUNDBREAK XP
2 LAYERS: GYPSUM SOUNDBREAK XP
1/8" SOUND CONTROL MAT
1" GYPSUM CONCRETE TOPPING
PERIMETER ISOLATION STRIP
ACOUSTICAL SEALANT
HAT CHANNEL
NEOPRENE ISOLATION PAD
NEOPRENE ISOLATION PAD
NEOPRENE ISOLATION WASHER
Scale
Date
3" = 1'-0"
A7.2
SECTION DETAILS
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
3" = 1'-0"1
Section Detail - SKYLIGHT HEAD AND
SILL
3" = 1'-0"2 Section Detail - SKYLIGHT JAMB
3" = 1'-0"3 Plan Detail - SOUND ROOM JAMB
3" = 1'-0"5 Section Detail - SOUND ROOM HEAD
3" = 1'-0"4 Section Detail - SOUND ROOM SILL
No. Description Date
06/18/2025
2x DOUBLE RAFTER
ASPHALT SHINGLE ROOF TO
MATCH EXISTING
SOLAR TUBE
INSULATION AS SCHEDULED
UNDERLAYMENT
SILL PAN WITH BACK AND END DAMS SET
IN SEALANT
AIR BARRIER
1X PAINTED WOOD SIDING
SOFFIT VENT
PAINTED WOOD SOFFIT PANEL
EXTERIOR SHEATHING
60 MIL ADHERED
WATERPROOFING MEMBRANE
1 1/2" TOPPING SLAB
SS FLASHING
LOOSE LINTEL
BRICK MOLDING
SEALANT
FLASHING SET IN SEALANT
SPACER
DRIP EDGE
AIR BARRIER
1X PAINTED WOOD SIDING
ALUMINUM 'T' BAR
SOFFIT VENT
PAINTED WOOD SOFFIT PANEL
BEAM - REF STRUCTURAL
60 MIL ADHERED
WATERPROOFING MEMBRANE
COVER BOLTS AND
EMBED IN SEALANT
1 1/2" TOPPING SLAB
EMBED
STEEL GUARDRAIL
SELECT GRADE RED OAK STAIR TREAD
AND RISER STAIN COLOR TBD
PLYWOOD SUBFLOOR - REF
STRUCTURAL
2X BLOCKING - PER STRUCTURAL
ENGINEER
7
3
/
4
"
M
A
X
FLOORING AS SCHEDULED
0' - 11"0' - 1"
SELECT GRADE RED OAK STAIR TREAD
AND RISER STAIN COLOR TBD
PLYWOOD SUBFLOOR - REF
STRUCTURAL
2X BLOCKING - PER STRUCTURAL
ENGINEER
BATT INSULATION
0' - 11"0' - 1"
7
3
/
4
"
M
A
X
Scale
Date
As indicated
A7.3
SECTION DETAILS
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
1 1/2" = 1'-0"1 Section Detail - TUBULAR SKYLIGHT
3" = 1'-0"2 Section Detail - BALCONY AT DOOR SILL
3" = 1'-0"3 Section Detail - BALCONY FASCIA
1 1/2" = 1'-0"4 Section Detail - STAIR BASE
1 1/2" = 1'-0"5 Section Detail - STAIR TOP
No. Description Date
06/18/2025
PRE-SLOPED KERDI SHOWER TRAY
KERDI-BOARD CURB
KERDI-BAND WITH KERDI-KERECK PRE-FORMED CORNERS
SILICONE SEALANT AT ALL CORNER JOINTS
TILE AS SCHEDULED
SCHLUTER-JOLLY
GLASS SHOWER ENCLOSURE
SCHLUTER DITRA
TILE AS SCHEDULED
PRE-SLOPED KERDI SHOWER TRAY
KERDI-BOARD
KERDI-BAND WITH KERDI-KERECK PRE-FORMED CORNERS
SILICONE SEALANT AT ALL CORNER JOINTS
TILE AS SCHEDULED
PRE-SLOPED KERDI SHOWER TRAY
KERDI-BOARD
KERDI-BAND WITH KERDI-KERECK PRE-FORMED CORNERS
SILICONE SEALANT AT ALL CORNER JOINTS
TILE AS SCHEDULED
1' - 3"
0'
-
0
1
/
2
"
RE
F
E
L
E
V
A
T
I
O
N
QUARTZ SHOWER BENCH
HSS 3 1/2" X 1 1/2" X 1/4" TUBE STEEL WELDED TO
STEEL PLATE FASTENED TO STRUCTURE ON
EACH SIDE OF THE BENCH. PROVIDE DOUBLE
STUDS WHERE PLATE IS SECURED.
KERDI-BOARD
KERDI-BAND WITH KERDI-KERECK
PRE-FORMED CORNERS
SILICONE SEALANT AT ALL CORNER JOINTS
TILE AS SCHEDULED
0' - 1"
QUARTZ
DOUBLE 2"X4" STUD
DOUBLE 2"X6" STUD
Scale
Date
3" = 1'-0"
A7.4
BATHROOM
DETAILS
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
3" = 1'-0"1 Section Detail - SHOWER CURB
3" = 1'-0"2 Section Detail - SHOWER WALL
3" = 1'-0"3 Section Detail - SHOWER SEAT
3" = 1'-0"4 Section Detail - SHOWER NICHE No. Description Date
06/18/2025
UP
2
20 AMP GFCI
DEDICATED CIRCUIT
20 AMP GFCI
DEDICATED
CIRCUIT - HOT
WATER HEATER
NEW ELECTRICAL PANEL
EXISTING ELECTRICAL PANEL
ELECTRICAL SERVICE
CONNECTION
RELOCATED SPRINKLER
CONTROL
20 AMP GFCI
DEDICATED HVAC
CIRCUIT
HVAC
DISCONNECT
Scale
Date
1/4" = 1'-0"
E1.1
GROUND LEVEL -
ELECTRICAL
PLAN
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
1/4" = 1'-0"1 GROUND LEVEL - ELECTRICAL PLAN
No. Description Date
06/18/2025
DN
DD 2
2 2
40 AMP DEDICATED POINT
OF USE OUTLET FOR
POINT OF USE HOT
WATER HEATER
ABOVE COUNTER OUTLET
BELOW COUNTER GFCI OUTLET
TV OUTLET 48" AFF
HVAC OUTLET - 20
AMP DEDICATED
ALL OUTLETS
IN THIS ROOM
ON A SINGLE
CIRCUIT
20 AMP GFCI
DEDICATED CIRCUIT
Scale
Date
1/4" = 1'-0"
E1.2
SECOND LEVEL -
ELECTRICAL
PLAN
CH
R
I
S
T
A
S
L
A
D
D
E
N
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
X
7
6
0
5
1
06/18/2025
1/4" = 1'-0"1 SECOND LEVEL - ELECTRICAL PLAN
No. Description Date
06/18/2025
CP #51
3/8"IR
MISC 3" PVC DISC SENTRICON
MISC POWER CONTROL CONSOLE
FF EL=604.11'
concrete
concrete
concrete
rock walkway
gravelwood retaining wall
rock retaining wall
wood retaining wall
wood retaining wall
wood retaining wall
wood retaining wall
House
wo
o
d
b
o
a
r
d
f
e
n
c
e
wo
o
d
b
o
a
r
d
f
e
n
c
e
wood board fence
12,500 square feet
(0.2870 acres)
John M. and wife Christa
C. Sladden
Volume 9145, Page 467
D.R.T.C.T.
Lot 24, Block 3
Western Oaks
Volume 388-204, Page 91
P.R.T.C.T.
N0
0
°
3
8
'
0
9
"
E
1
4
8
.
2
5
'
S89°21'51"E 84.32'
S0
0
°
3
8
'
0
9
"
W
1
4
8
.
2
5
'
N89°21'47"W 84.32'
Lot 25, Block 3
Western Oaks
Volume 388-204, Page 91
P.R.T.C.T.
Lot 23, Block 3
Western Oaks
Volume 388-204, Page 91
P.R.T.C.T.
Lot 22, Block 3
Western Oaks
Volume 388-204, Page 91
P.R.T.C.T.
Lot 21, Block 3
Western Oaks
Volume 388-204, Page 91
P.R.T.C.T.
S89°21'47"E 84.31'
N0
1
°
2
5
'
0
7
"
W
5
0
.
0
3
'
40' building line
10'x10' T.P. & L. Easement
Volume 388-204, Page 91
P.R.T.C.T.
10' Utility Easement
Volume 388-204, Page 91
P.R.T.C.T.
604
60
4
603
60
3
60
2
60
1
603.85 603.86
GR603.61
GR603.61
GR603.61
GR603.61
603.95
GR604.11
604.11
603.96
604.09 604.11
604.09
604.11
603.50
CAUTION:
UNDERGROUND ELECTRIC
TO BE RELOCATED. CONTACT LOCAL
UTILITY PROVIDER
CAUTION:
UNDERGROUND ELECTRIC
TO BE RELOCATED. CONTACT
LOCAL UTILITY PROVIDER
EXISTING RESIDENCE
2803 HIGHCREST DRIVE
F.F. = 604.11
EXISTING RESIDENCE
ADDITION
2803 HIGHCREST DRIVE
F.F. = 604.11
EXISTING TREES LOCATED IN ADDITION
AND PATIO TO BE REMOVED AS DIRECTED
BY OWNER ( HAUL OFF DEBRIS)
REMOVE EXISTING ROCK
ROCK WALKWAY AS NEEDED TO
CONSTRUCT NEW ADDITION
OR DIRECTED BY OWNER
AC UNITS
REMOVE EXISTING ROCK
GRAVEL AS NEEDED TO
CONSTRUCT NEW ADDITION
OR DIRECTED BY OWNER
HIGHCREST DRIVE
Know what's below.
before you dig.Call
R
@least 48 hours prior
28
0
3
H
I
G
H
C
R
E
S
T
D
R
I
V
E
X
LEGEND
NOTES
DRAINAGE NOTESMINIMUM CLEARANCE
PER SECTION
R404.1.6 AND
R317.1 TYP
12" MINIMUM DEPTH
OR GREATER FOR
FROST PROTECTION
R403.1.4 AND
R403.1.4.1 TYP
3.5" MINIMUM
CONCRETE SLAB
PER SECTION R506.1
W
MONOLITHIC SLAB-ON-GROUND
WITH TURNED-DOWN FOOTING
NOT TO SCALE
BOTTOM (SOLE) PLATE
ATTACHED PER SECTION
R403.1.6
NOTES
EXH-1