HomeMy WebLinkAboutPLIRR2024-004268Texas Commission on Environmental Quality 7.131t _Re fbfloy�n form must he can leted for each aganifl, . tested. A gi;=,ied and dated oriEinal must be submitted to ft. ublic watersu Bier for r=rdk-c0n-_ *,,u& -o= NAME OF PWS: Gra: in PWS ID#: PWS MAILING ADDRESS: _5015hady Br.Qok PWS CONTACT PERSON: Back1low Coordinator ,P�DDRESS OF SERVICE: 316 Tillgry,Cir The baco­w prevention assembly detailed below has been tested and maintained as required by commission regulations and is certified to be opera. Ec wit�in acqp-ptabl qerL_ TYPE OF BACKFLOW PREVENTION ASSEMBLY (BPA,: Reduced Pressure Principle (RPBA) 0 Reduced Pressure Principle-Det(RPB ector A-D) Type 11 . Vey.® 01 V Double Check Valve (DCVA) Double Check -Detector (DCV-D) T� r e H 11 Pressure Vacuum Breaker (PVB) Spill -Resistant Pressure Vacuum Breaker (SVB) Manufacturer.- main: Wilkins Bypass- I Size: in: Bypass: 1; Model Number: main: 350 BypassJ1 _WBPA on: Front SeX seryLocatirial Number- Main: AJAD7636 Bypasses: Irrigation - PERMIT NUMBER: 24-004268 Reason for test: New Existing 0 Replacement jOldModel/Serial#1 I Is the assembly installed in accordance with manufacturer recommendations and/or local codes? es '10'No Is the assembly installed on a non - potable water supply (auxiIiary)? ea ;Yes TEST RESULT Type H Reduced Pressure Principle Assembly (RPBA) Assembly PV`B & SVB PA SDCVA S else ve Bypass Check Air Inlet i! Check Valve Rf Val FAEL 0 V Check 2nd Check*** Held at Paid'Opened at: id,� Held at jwtiai Test i�Heid at 2 3 psi :2.4 � JI Held a� _] psid Opened at' ps psid. Date-12115/2024 ;,Closed Tiigrht Closed Tight psid Closed Tight El Did not open lb "Time: id not ti 05:20 PM i'Leaked Lcakcd 'Leakud 0 Did it &I.Ily open Leaked open 10' (YesID/No, 1 7777 Repairs and :;Main-'; Naterials d]Used** Bypass: Test After Held at sr ''field at paid Opened at t! Held at psid::�'Opened at psid: Held at lClosed paid „._.�.... K& air psid Closed Tight [2 Closed Tight ate:JTfight D Ti4 me: 2nd cheek. net readine recuired for DCVA onle Differential pressure gauge used: Potable: Non -Potable: maketmodei: Midwest 845-5 SN: 01.151,514 Date tested for accuracv': 06/2812024 Remarks; Company Name: Classic Backflow, LLC. Licensed Tester Name PrintlTy ): Charles C® Address: ,3025 Oak Meadow Dr Licensed Tester Name (Signature): flower Mound, TX 75028 i - I Company Phone 1 214-535-3341 BPAT License # I BP00164-31 License Exi.iration Date: 03/1712,027 The above is certffled to be true at the thine of testift. TEST RECORDS MUST BE KEPT FOR AT LEAST THREE YEARS [30 TAC §290.46(B)l ** USE ONLY MANUFACTURER'S REPLACEMENT PARTS TCEQ-20700 (Revision 04-04-2019) Page 1 of I