Loading...
HomeMy WebLinkAboutPLIRR2024-004270Texas Commission on Environmental Quality pliltewror $ATWt1M%b _Re foilovrin_ fTn iynN com,leted for each i® tested- A sig-ied and dated original must be submitwd to ffie ublic water su, lier for rCCoTdkMr'in'_ *, U1 0=' NAlvfE OF PWS: _.Gra,.,e%ane Piws U)#- PWS MAILING ADDRESS: PWSCON TACTPERSON: -7 Backflow Coordinator A�bbRESS O�­ShRVICE- 308. -Tills, ery-Cir The backflow prevention assembly detailed below has been tested and maintained as required by commission regulations and is ceWfled to be opga"t: wi in accepj�e p�jaTj th qte sj TYPE OF BACKFLOW PREVENTION ASSEMBLY MPA Reduced Pressure Principle (RPBA) 0 Reduced Pressure Principle -Detector (RPBA-D) Type 110 V Double Check Valve (DCVA) 1 10 Double Check -Detector (DCVA-D) H El Pressure Vacuum Breaker (PVB) .0 Spill -Resistant Pressure Vacuum Breaker (SVB) Manufacturer: main: Wilkins ass-; Size: Main: Bypass: 1, Model Number: Main: 350 Bypassfl PA L:�ation :J Front S Serial Number. main:, AJBGS,712BYPa-;sV -1-BEPA es- Irrigation PERMIT NUMBER: 24-004270 Reason for test: lNew :V Existing D Replacement Ell O1dModeI1Scria1#j Is the assembly installed in accordance with manufacturer recommendations andlor local codes. NO 10 jVes j)JI!o Is the assembly installed on a non -potable water supply (auxiliary)'? 'TEST RESULT Type H Reduced Pressure Principle Assembly (RPBA) Assembly PVB & SVB, P PAS9 8(i DCVA Che Relief Valve Bypass Check Air Inlet ck a1ve FAIL 0 1,' Check 2' Check* 'ps J psid Held at lidtial Test "Heldat 2.1 �psi 'Held at,2A.3 psid Opened at _'i jl� Held at id Opened at, —Closed Tight rht ::Didnotopen 1[j paid t, i psid Closed Tight Closed Tight '0 Time: l,'Did not :0a. .0 Leaked Leaked 'Leaked Did fitfully open 05:30 pM Leaked 01 0 open (YesI 01) . . .......... Repairs and �:Main:' Materials Used" Bypass: 1LLTest After Held at psid Held at psid Opened at I ��Held at; i psid Opened at' psid Held at MR2 air :�ClosedTight D Closed Tight q;➢��psid jClosed psid D7 ate: jight U Time: 21 check. numeric reading recittired for DCVA on1% Differential press e gauge used: Potable: V Non -Potable'. El' m . aketmodei: Midwest - 845 1 -5 sN: 0 1 .. i5l 51A Date testa- , d I for accuracy I 11 ''06/28/2o24 Company Name: Classic Backflow, LLC Licensed Tester ame NCharl�, .!`is- (Print/Tv,., Company Address- ;3025 Oak Meadow Dr Licensed Tester Name (Signature): Flower Mound, TX 75028 Company one BPAT License # I BP0016431 1214-535-3341 License Exi tion Date: 03/17t2O27 The above is certified to be true at the time of testing. TEST RECORDS MUST BE KEPT FOR AT LEAST THREE YEARS [30 TA C §290.446(B)] ** USE ONLY MANUFACTURER'S REPLACEMENT PARTS TCEQ-20700 (Revision 04-04-2019) Page 1 of 1