Loading...
HomeMy WebLinkAbout74610_10136_050525-24-DM9103-084-CompressiveStr-AT24-DM9103Project #: Z Constructors 2051 State Hwy 121, Grapevine, Texas 76051 Proposed Stuarts Paint and Body Shop" 2051 State Hwy 121, Grapevine, TX 76051 Location: Project: Client:Report Date:05/05/2025 DESIGN, FIELD & LAB DATA Location: Air Temp (F):N/A Inside the location Truck No:Ticket No:Inside the location Capping Method: No. of Specimens:3 / 6x12 Time Sampled:8:00 AM Time Batched: Forming Method:Load Qty:Slump (In):NR Wall side Weather: Min Temp: Specimen Age at Time of Transport to Lab: Grout Temp:0 Inside the location Supplier: Curing History: Max Temp: Sampled:By the west wall Date Placed: Admixtures: Design Strength: Design Slump (Inches): 2000 psi @ 28 days Break Days:7,28,28 Mix No/Design: Na Contractor: Mix Type/Procedure: 05/05/2025 1 Load #: Prism ID Test Age (Hours / Days) Date of Test Total Load (lbs) Prism Dimensions Width (in)Avg. Width (in) Prism Dimensions Height (in)Avg. Height (in) Avg. Cross Section Area Test Strength (psi) 8|<1/8"?4P<1/8"?Tested by Type of BreakW1W2W3W4H1H2H3H4 0505-24-DM9103-G-A-A 7 days 05/12/2025 13,660 4 4 7 7 5.50 8 8 8 8 8.00 30.25 450 0 0505-24-DM9103-G-A-B 28 days 06/02/2025 0.00 0.00 0 0505-24-DM9103-G-A-C 28 days 06/02/2025 0.00 0.00 0 0.00 0.00 LAB RESULTS Set No:Lab ID:1894Date Received:05/06/2025 1894 Are Prisms made by Contractor?Are Prisms picked up by Contractor?RESULTS COMPLY RESULTS DO NOT COMPLY Note: Test Methods ASTM C1019 (excluding 5.2, 11.4, 11.5), C39, C511, C143, C617, C1064. Deviations from Test Method: Specimens were cast in corrugated cardboard prism mold (Grout Sample Box) without comparative test results with molds described in 5.1. Min/Max temperature at curing not performed unless noted above. Results Spec: 2000 psi @ 28 days Chris, Mommi Carter, Tyler George Report Copied to: Compressive Strength - Grout Specimens (ASTM C39) 084Report #: Page 1 of 2 GeoScience Engineers, LLC, 2712 Satsuma Drive, Suite 400 | Dallas | TX 75229 | Phone: 972-488-3500 | Email: info@geoscienceinc.com www.geoscienceinc.com 24-DM9103Project #: Z Constructors 2051 State Hwy 121, Grapevine, Texas 76051 Proposed Stuarts Paint and Body Shop" 2051 State Hwy 121, Grapevine, TX 76051 Location: Project: Client:Report Date:05/05/2025 Field Representative: Ali Tamimi Cert No: Lab Representative: Hayder Toman 8|<1/8"? - 8 perpendicularity measurements less than 1/8"? 4P<1/8"? - 4 out of plane measurements less than 1/8"? GeoScience Engineers, LLC CMT Admin Date Signed: 05/21/2025 12:05 PM Notes: The results above apply only to the specific samples noted using the aforementioned test method(s) and do not represent any other sample. Reports may not be reproduced except in full without permission. Compressive Strength - Grout Specimens (ASTM C39) 084Report #: Page 2 of 2 GeoScience Engineers, LLC, 2712 Satsuma Drive, Suite 400 | Dallas | TX 75229 | Phone: 972-488-3500 | Email: info@geoscienceinc.com www.geoscienceinc.com