HomeMy WebLinkAbout74622_10154_040725-24-DM9103-006A-ReinforcingSte-JV04/07/2025Report Date:Client:
Project:
Location:
Proposed Stuarts Paint and Body Shop" 2051 State Hwy
121, Grapevine, TX 76051
2051 State Hwy 121, Grapevine, Texas 76051
Z Constructors
Project #:24-DM9103
FIELD DATA
?Contractor:
General Location:North end of bp addition
Plans or RFI Available:No XYes N/A
Weather:Sunny cool
47Temperature:
Sheets/Details:.Plans Dated:04/07/2025
INSPECTION SUMMARY
Level Location/Gridline Description Type*Inspection Status
1 North end of bp addition 6" wire mesh Conformance
YES NO N/A
Reinforcement supported per specifications X
Proper number of bars per drawings X
Openings reinforced as per drawings X
Columns and lintels per schedules X
Forms are sufficiently clean X
Weather protection in place X
YES NO N/A
Reinforcement proper size and grade X
Reinforcement clean and free of excess rust X
Reinforcement has the proper spacing X
Reinforcement splices per specifications X
Reinforcement has minimum clearance X
Reinforcement placed per drawings X
OBSERVATION ITEMS
ADDITIONAL DETAILS
*FTG: Footings; FND: Foundations; WL: Walls; SOG: Slab On Grade; SOMD: Slab On Metal Deck; SS: Suspended Slab; CL: Columns; TU: Tilt-Up
All Cables Present With the Correct Profile X
INSPECTION RESULTS AND NON CONFORMANCE
RFI (Request For Information)Follow-up Visit RequiredFinalXWork In Progress
ConformingX Non-Conforming
The work was observed or monitored by our personnel and found to be:
Remarks:6"wire mesh was used on bp addition at North end
Report Copied to: Chris, Mommi Carter, Tyler George
Representative/Inspector: Javier Valle
GeoScience Engineers, LLC
CMT Admin
Date Signed: 04/23/2025 01:50 PM
Notes: As requested, a representative from our company arrived on site as scheduled and performed the above test. These test results apply only to
the specific locations noted and do not represent any other location. Reports may not be reproduced except in full, without permission.
Reinforcing Steel Observation
006AReport #:
Page 1 of 2
GeoScience Engineers, LLC, 2712 Satsuma Drive, Suite 400 | Dallas | TX 75229 | Phone: 972-488-3500 | Email: info@geoscienceinc.com
www.geoscienceinc.com
04/07/2025Report Date:Client:
Project:
Location:
Proposed Stuarts Paint and Body Shop" 2051 State Hwy
121, Grapevine, TX 76051
2051 State Hwy 121, Grapevine, Texas 76051
Z Constructors
Project #:24-DM9103
Field Report [s]
Reinforcing Steel Observation
006AReport #:
Page 2 of 2
GeoScience Engineers, LLC, 2712 Satsuma Drive, Suite 400 | Dallas | TX 75229 | Phone: 972-488-3500 | Email: info@geoscienceinc.com
www.geoscienceinc.com