Loading...
HomeMy WebLinkAboutCOMA2019-002291DATE OF ISSUANCE: GRAPENTINE Z 1' E A PERMIT #: Q BKILWNGTERMIT, APPLICATION, J'LEAISE FRUNT LECABLY F EYTIRL"' FORNI) JOB ADDRESS: �3) NA,,� IW�U'ITE # zz= VA-�t� - _1(900 (-6 LOT: BLOCK: SUBDMSION: BUILDING CONTRACTOR (company name): y_e ,-Xnco- 60^5y",kCW, (9,C00P, L-L--r— CURRENT MAILING ADDRESS: 241-62- TM CITY/STATE/ZIP: PH: Fax# L461 PROPERTY OWNER: 4f4 CURRENT MAILING ADDRESS: L4YeS;-' CA-. CITY/STATE/ZIP: PHONE NUMBER: 91-+/ 5 2.'1 '12- PROJECT VALUE: $ 2-(;52-, FIRE SPRINKLERED? YES— NO WHAT TRADES WILL BE NEEDED? ilzw applY,, ELECTRIC V--�P-LUMBING MECHANICAL DESCRIPTION OF WORK TO BE DONE: USE OF BUILDING OR STRUCTURE: Pri'4'k\,-- NAME OF BUSINESS: 7-�eJKAD-4u-, Acc-,;-ew-,r Total Square Footage under roof-S(01 Square Footage of alteration/addition: I hereby certify that plans have been reviewed and the budding will be inspected by a certified energy code inspector in accordance with State Law. Plan review and inspection documentation shall be made available to the Building Department (required for new buildings, Iterations and additions) hereby certify that plans have been submitted to the Texas Department of Licensing and Regulation for Accessibility Review. Ctrol Number: o 1 (1 3, (Not required for I & 2 family dwellings) on hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas Department of Health. (REQUIRED FOR DEMOLITIONS, ADDITIONS AND OR ALTERATION TO COMMERCIAL AND PUBLIC BUILDINGS) I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by the Building Department and in compliance with the City Of Grapevine Ordinance regulating construefion. ,1tis—understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City Of G evine. URT ERMORE UNDERSTAND THAT PLANS AND SPECIFIC NS ARE NOT REVIEWED FOR HANDICAPPED CESSI B HE CITY, AND THAT THE DESIGN PROFESSIONAL/O IS RESPONSIBLE FOR OBTAINING SUCH AP OVAL M T APPROPRIATE STATE AND OR FEDERAL AGENCY(S . PRINT NAME: O)e^ - 7Le,4, SIGNATURE PHONE#: EMAIL: CHECK BOX IF PREFERRED TO BE CONTA D BY E-MAIL THE FOLLOWING IS TO BE COMPLETED BY THE BUILDING INSPECTION DEPARTMENT Construction Type: Permit Valuation: $ -'2 -;7 7 Setbacks Approval to Issue Occupancy Group: jf--- Fire Sprinkler: YES X NO Front: Electrical 'y Division: Building Depth: Left: Plumbing Zoning: Building Width: Rear: Mechanical Occupancy Load: 4�0,,F�3 d--1 !� '�Right: -7� Plan Review Approval: Date: �e� Building Permit Fee: Site Plan Approval: /-' - '-- Date: Plan Review Fee: Lapo °Fire Department: 194,e i�r4o i t' Date: 7.Z-.- Lot Drainage Fee: Public Works Deptartment: Date: Sewer Availability Rate: Health Department: Date: Water Availability Rate: Approved for Permit: Date: Total Fees: Lot Drainage Submittect---- - Approved: Total Amount Due: P.O. BOX95104, GRAPEVINE, TX 76099 (817)410MI65 O:FORMSkDSPERMITAPPUCATIONS 1/02-Rev. 1 1,04,5106.2t07,11109A/11 ' BUILDING --COMMERCIAL ALTERATION Issue Date: July 3,umo � DESCRIPTION: Interior Remodel and Addition of new Walls for New Tenant'The Novus VXPROJECT Academy" (CO 1o'uxxr) ' PROJECT# (817)440-3010 mmxW'mmygwv.um C0MA' 9.2291 i ymspam#omm Permits City of Grapevine P.O. Box 95104 mCAmow TENANT Lemu empmmu' Tx ronon a4noWilliam DTate Ave. What IfwmCould Bedba The Grapevine niAddition B|k1 (a1r)wo'u,oaVoice Suite #1ouo NovusAcodemx Lot1 (un)wu'nooFax . Grapevine, TX7VV51 comreAcrou /wponMxrmw The Alliance Construction Group, LLC. ^ CONDITIONAL USE REQUIRED? YES P. D. Box8O388 ^ CONSTRUCTION TYPE ||-B KoUmr, TX ' ^ OCCUPANCY GROUP E/B (817)33r-4V42Phone ^OCCUPANCYLOAD 448 (489)453-3027Fax *ZONING CC (O17)1O1-78UVMobile ~NAME 0FBUSINESS The NnvuaAcademy —APPLICANT NAME Cory Lee owwEa —APPLICANT PHONE NUMBER 840'241-1790 Cal-texAquisiUonV *SITE PLAN / SPECIAL USE /CU? CUP 19'01 214OHall Johnson RdSte 1O2 � 1>CeifiodEnergy Code Inspected YES Grapevine, TXr0851-07VO 2)Accessibility Review YES AVAILABLE INSPECTIONS 3)Control Number TABG2019013370 ° Building Framing (mquied) 4>Asbestos Survey YES °Building Energy Code (moui,*d) ° Final Fire Dept Inspection (rmqvimd) Acreage ' Building Final (required) APPROVED TOISSUE ELECTRIC YES APPROVED TOISSUE HOOD NO APPROVED T0ISSUE MECHANICAL YES APPROVED TDISSUE PLUMBING NO County Tarrant Fire Sprinkler System? YES Square Footage 17700 VALUATION 202708 What isuse ofBuild ing/Souctum? School *Building Permit Fee (kb*e) $1,402.25 Building Plan Review $81146 pAvMEwro TOTAL =$u'nm.n The Alliance Construction Group, LLC.(Cory Lee) ($V11�0 Ch�koo���0/9 ` Note: CK6001 The Alliance Construction Group, LLC. (Cory ($1.4O225) w,00voa City mGrapevine | BUILDING --- COMMERCIAL ALTERATION |cow«1s-2a 1|pnwe 07/03/19at 12:03p.= Page 1mn Check on 0710312019 Note: CK6058 NOTICES 1) ALL work must be done in compliance with the 2006 INTERNATIONAL BUILDING CODE. 2) A copy of the signed permit and approved plans must be on site at all times. 3) The project address must be clearly posted at the job site. READ AND SIGN I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by the Building Department and in compliance with the City of Grapevine Ordinance regulating construction. It is understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City of Grapevine. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED F05 HANDICAPPED ACCESSIBILITY BY THE CITY, AND THAT THE DEIGN f�ROF NAL / OWNER IS RESPONSIBLE FOR OBTAINING SUCH�APPROVAL ROM THE APPROPRIATE STATE AND OR FEDERAL AGENCY(p�}. Signature Date MYGOV.US City of Grapevine I BUILDING --- COMMERCIAL ALTERATION I COMA-19-2291 I Printed 07/03/19 at 12:03 p.m. Page 2 of 3 ELECTRICAL PERMIT (VALUE) A ` 'E Issue Date: July 16, 2019 ,GR< a t is g v -t S . PROJECT DESCRIPTION: Interior Remodel (Install Outlets & Relocate Light Fixtures) 'The Novus Academy" PROJECT# (817)410-3010 WWW.mygov,us EL.EC-19-2872 Inspections Permits City of Grapevine P.O. Box 95104 LOCATION TENANT LEGAL Grapevine, Tx 76099 3400 William D Tate Ave. What If We Could Be dba The Grapevine lii Addition Blk 1 (817) 410-3165 Voice Suite # 1000 Novus Academy Lot 1 (817) 410-3012 Fax Grapevine, TX 76051 CONTRACTOR INFORMATION ASSOCIATED ELECTRICAL SYSTEMS County Tarrant State ID # 325551 Square Footage 177 231 RANCHO DR VALUATION 13000 FORT WORTH, TX 76108-9212 (817) 929-6062 Phone FEES TOTAL = $ 144.00 Electrical Permit Fee {VALUE) $ 144.00 OWNER PAYMENTS TOTAL = $ 144.00 Cal-tex Aquisition V 2140 Hall Johnson Rd Ste 102 ASSOCIATED ELECTRICAL SYSTEMS Grapevine, TX 76051-8760 (RUSS TATE) ($144.00) Cc on 0711512019 AVAILABLE INSPECTIONS NOTICES ► Electrical Rough (required) ALL work must be done in compliance with the 2005 NATIONAL ELECTRIC ► Electrical Final (required) CODE. PLAN SUBMITTAL: WHEN PLANS ARE REQUIRED BY CODES, ORDINANCES, OR AS DETERMINED BY THE BUILDING OFFICIAL, THREE (3) SETS OF PLANS SHALL BE SUBMITTED IN HARD COPY FORMAT. ENGINEER SEALED PLANS AND CALCULATIONS SHALL BE SUBMITTED AS REQUIRED BY CODES, ORDINANCES OR WHERE OTHERWISE REQUIRED BY STATE LAW. READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND / OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS, AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST. MYGOV.US City of Grapevine I ELECTRICAL PERMIT {VALUE) I ELEC-19-2872 I Printed 07/16/19 at 8:08 a.m. Page 1 of 3 City of Grapevine P.O. Box 95104 Grapevine, TX 76099 (817) 410-3165 Voice (817)410-3012 Fax CONTRACTOR AMC Services, Inc. State ID # TACLA015336C 9100 US 380 Crossroads, TX 76227 (972) 466-2656 Phone (972)730-9428 Fax (940) 600-9835 Mobile MECHANICAL PERMIT {VALUE} Issue Date: August 8, 2019 PROJECT DESCRIPTION: Relocate a few ducts 'The Novus Academy" PROJECT # L(817) 410-3010 WWW.Mygov.us M ECH-19-3246 Inspections Permits LOCATION TENANT LEGAL 3400 William D Tate Ave. What If We Could Be dba The Grapevine Ili Addition Blk 1 Suite # 1000 Novus Academy Lot 1 Grapevine, TX 76051 OWNER Cal-tex Aquisition V 2140 Hall Johnson Rd Ste 102 Grapevine, TX 76051-8760 AVAILABLE INSPECTIONS ► Mechanical Duct (required) ► Mechanical Rough (required) ► Mechanical Final (required) INFORMATION Is Duct Work Being Installed? YES Square Footage VALUATION 8600 FEES TOTAL = $ 104.40 Mechanical Permit Fee (Value) $ 104.40 PAYMENTS TOTAL = $ 104.40 AMC Services, Inc. (Rob Glenn) Cc on 0810812019 ($104.40} NOTICES ALL work must be done in compliance with the 2006 INTERNATIONAL MECHANICAL CODE. PLAN SUBMITTAL: WHEN PLANS ARE REQUIRED BY CODES, ORDINANCES, OR AS DETERMINED BY THE BUILDING OFFICIAL, THREE (3) SETS OF PLANS SHALL BE SUBMITTED IN HARD COPY FORMAT. ENGINEER SEALED PLANS AND CALCULATIONS SHALL BE SUBMITTED AS REQUIRED BY CODES, ORDINANCES OR WHERE OTHERWISE REQUIRED BY STATE LAW. READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND / OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS, AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST. Signature Date MYGOV.US City of Grapevine I MECHANICAL PERMIT (VALUE) I MECH-19-3246 I Printed 08/08/19 at 2:57 p.m. Page 1 of 3 UILDING CODE REVIEW r (11 10C z SUMMARY AND CHEC LIST TO BE COMPLETED BY PLANS EXAMINERS r ADDRESS_- / - � DATE /,, - -P? NEW CONSTRUCTION RENOVATION ALTERATION 1WW,1e4 ADDITION TENANT FINISH OUT HISTORIC -� i f ZONING DISTRICT PERMITTED USE YES �NO rf CUP :'YES ` NO NUMBER / - SPECIAL USE: YES NO '`f SITE PLAN: YES NO PERMIT'S DATE, LOCATION ON PROPERTY EXTERIOR WALL(S) RATING: FRONT H/R RIGHT H/R REAR H/R LEFT H/R DIST TO PROP LINE (FEET) N - E - S - W - BUILDING WIDTH: BUILD DEPTH: BUILDING HEIGHT: REQUIRED FIRE RESISTANCE: YES NO FIR RATING: HORIZ VERT USE AND OCCUPANCY OCCUPANCY CLASSIFICATION Group Division Group Division Group Division Group Division Group Division Group Division Group Division Group Division Group Division Fire Sprinkler YES —'ENO _ Required YES 0 Fire Alarm YES -"NO _ Required YES _--"NO _ SPECIAL OCCUPANCIES Special Occupancies Yes No Group Division Group Division Group Division Group Division Group Division Group Division OCCUPANCY SEPARATIONS r� REQUIREDYES_ NO FIR RATING HORIZ VERT NON -SEPARATED USES YES _ NO SEPARATED USES YES _ NO DEMISING WALL PARTY WALL TENANT PARATION ��, MAXIMUM• ' : • •' AREA N,1A Maximum Allowable Floor Area per Table + Area Increase + Sprinkler increase = Total Maximum Floor Area including increases MAXIMUM ALLOWABLE BUILDING HEIGHTb Maximum Allowable Height per Table increase = INCREASES Frontage NUMBER OF STORIES: 1 �- Type of Construction: +Story Increase + Sprinkler Total Maximum Height/Stories including increases Sprinklers Unlimited Area SEPARATED USES UNITY FORMULA CONSTRUCTION TYPE Type IA Type IB Type IIA Type IIB Type IIIA Type IIIB Type IV — Heavy Timber Type VA Type VB Protected: Unprotected: FIRE RESISTIVE CONSTRUCTION Required: Yes No °j FW _ FB Shaft Openings Opening Area Allowed Per Table Rated Opening_ FIRE WALL FIRE BARRIER SMOKE PARTITION C•Z4L•1II'7_1►1a0111�� TOTAL SQUARE FOOTAGE ALTERED SQ FTG: ,; SQUARE FOOTAGE OF USE / OCCUPANT LOAD FACTOR = OCCUPANT LOAD FOR BUILDING Group - Division�� g+z,t, Group Divisi n Group Division Group Division Group Division Length of pews/benches # of Fixed Seating # of Booths TOTAL OCCUPANT LOAD Number of Exits Required Number of Exits Provided Total Exit Width Required Total Exit Width Provided % OTHER FLOORS: Number of Exits Required Number of Exits Provided Total Exit Width Required% Total Exit Width Provided OCCUPIED ROOFS: f Number of Exits Required Number of Exits Provided Total Exit Width Required Total Exit Width Provided CONVERGENCE: Number of Exits Required Number of Exits Provided Total Exit Width Required Total Exit Width Provided Correct Placement % Diagonal served 1/3 Diagonal Served Correct Swing of Exit Doors Door Landings Length Width Hardware: Panic or Fire Exit &9tj79ea Accessible a N/A Travel Distance Common Path l- Occupancy Type �- Stairs Yes No Rise/Run Rails Guards Landing _ Rated Shaft _ Rated Openings Penetrations Width Height INTERIOR ENVIRONMENT INTERIOR WALL AND CEILING FINISH MATERIALS: Floor/Wall Coverings: Noted on plans Impervious Floor Coverings: Noted on plans REQUIRED SPECIAL INSPECTIONS f Steel Welding High -strength bolts Details Concrete Materials _ Masonry Wood Soils Pile foundations Pier foundations Sprayed fire- resistant materials Density _ Bond strength Mastic and intumescent fire-resistant coatings Exterior insulation and finish systems (EIFS) Special inspection for smoke control _ Other Notes:. ,� TDLR TABS - Manage Project 0 Dashboard V Project Project ID : TABS2019013370 Project Name: Novus Academy Building or FacilityName: Grapevine III Address : 3400 William D. Tate Ave., Suite 1000, Grapevine, TX 76051,Tarrant Last Action : Project Registered Scope of Work: Tenant Improvement Estimate of square footage : 17700 Status : Project Registered Est. Start Date 6/17/2019 Est. End Date 8/1/2019 Estimated Cost: $250,000 Job Class : Renovation/Alteration Owner Class : This project is privately funded, on private land for private use. Private Funds Provided By Tenant? : Yes Owner: Cal -Tex Acquisition V, LLC Tenant: Kathy Edwards RAS: FRED DEAKSHINAULT State Project?: No State Lease Number: Special Category Project?: No Plan Review By: Inspection By : Last Updated By : Zachary Pearson A Contact Info �0 https://www.tdIr.texas.gov/TABS/Project/ManageProjecUdf76d9ba-5480-41 b7-9fO5-cc2lifafc9ed?currentid=zpearson%2540entosdesign.com 1/2 March 28, 2019 Todd Howard T Howard & Associates 1506 W Griffin St Dallas, TX 75215 Re: GRAPEVINE FILE #CU19-01 To Whom It May Concern, This letter is to verify that your request for a conditional use permit located at 3400 William D Tate Avenue and platted as Lot 1, Block 1, Grapevine III requesting a conditional use permit to amend to allow for a private school in the "CC" Community Commercial District was approved by City Council on March 19, 2019 with the condition that the applicant establish and maintain a plan that avoids queuing or stacking of vehicles on public roadways. A copy of the approved site plan and ordinance are attached. On March 19, 2019, the Planning and Zoning Commission recommended the City Council approve the request as stated above. Any changes to a site plan approved with a conditional use or a special use (no matter how minor or major) can only be approved by city council through the public hearing process. No Conditional Use Permit shall be valid for a period longer than one (1) year from the date on which the City Council grants the Conditional Use, unless within such one (1) year period: (1) a Building Permit is obtained and the erection or alteration of a structure is started, or (2) an Occupancy Permit is obtained and a use commenced. The City Council may grant one additional extension not exceeding one (1) year, upon written application, without notice or hearing. No additional extension shall be granted without complying with the notice and hearing requirements for an initial application for a Conditional Use Permit. Please do not hesitate to contact us if we may be of further assistance (817)410-3155. Since ly, Susan Batte Planning Technician DWELOPMENT SERVICES DEPARTMENT The City of Grapevine • P.O. Box 95104 . Grapevine, Texas 76099 • (817) 410-3154 Fax (817) 410-3018 • www.grapevinetexas.gov ��700'0 DROP—OFF/PICK—UP LOCATION Ni10 ..,._...,,� tz I I I � I z z z J I ` 2 ' �\/ol / PARKING UNDER BUILDING " / tt I/ / i M � I I , I Ij � L / V, PROPOSED I GYMLL ADDITION F/F 567.00 (IT c / a I3 s 12 I r , STUDENT DROP-OFF/PICK-UP COMcheck Software Version 4.1.1.0 Interior Lighting Compliance Certificate Project Information Energy Code: Project Title: Project Type: Construction Site: 3400 WILLIAM D. TATE AVE. GRAPEVINE, TX 76051 Allowed Interior Lighting Power 1-Office 2015 IECC NOVUS ACADEMY PHASE 1 Alteration Owner/Agent: Designer/Contractor: ADS Engineering 5020 Tennyson Parkway Plano, TX 75024 (214) 432-3030 A Area Category Area Category Exemption Qualifications Activity Area Office (4377 sa.ft.) Exemption: Less than 10% fixture replacement. Proposed Interior Lighting Power B C D Floor Area Allowed Allowed Watts (ft2) Watts / ft2 (B X C) Total Allowed Watts = N/A # Fixtures Total # Watts Pre -Alt. Repl./Added Pre -Alt. Post -Alt. 60 0 3480.000 2990,000 A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. Office (4377 so.ft.): Exempt Linear Fluorescent 1: E. 2X4: 48" T8 32W: Electronic: 2 17 65 1105 Linear Fluorescent 1 copy 1: R. 2X4: 48" T8 32W: Electronic: 2 29 65 1885 Total Proposed Watts = N/A Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Jake King - AOS Engineering 06-06-19 Name - Title Signature Date Project Title: NOVUS ACADEMY PHASE 1 Data filename: S:\2611-001-19 Novus Academy Phase I\COMcheck\2611-001-19 Lighting COMcheck.cck Report date: 06/06/19 Page 1 of 5 COMcheck• ' Inspection Checklist Energy ••- 1 Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plan Review Complies? Req.i C103.2 Plans, specifications, and/or ❑Complies [PR4]1 calculations provide all information ❑Does Not with which compliance can be ❑Not Observable determined for the interior lighting Not Applicable and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Additional Comments/Assumptions: Comments/Assumptions 1 High Impact (Tier 1) 2 I Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) r Project Title: NOVUS ACADEMY PHASE 1 Report date: 06/06/19 Data filename: S:\2611-001-19 Novus Academy Phase I\COMcheck\2611-001-19 Lighting COMcheck.cck Page 2 of 5 section Rough -in Electrical Inspection Complies? Req.113 C405.2.1 Lighting controls installed to uniformly ❑Complies [EL15]1 reduce the lighting load by at least ❑Does Not 50%. ❑Not Observable ❑Not Applicable C405.2.1 Occupancy sensors installed in ❑Complies [EL18]1 required spaces. ❑Does Not ❑Not Observable ❑Not Applicable C405.2.1, Independent lighting controls installed ❑Complies C405.2.2. per approved lighting plans and all ❑Does Not 3 manual controls readily accessible and ❑Not Observable [EL23]2 visible to occupants. ❑Not Applicable C405.2.2. Automatic controls to shut off all ❑Complies 1 building lighting installed in all ❑Does Not [EL22]2 buildings. ❑Not Observable ❑Not Applicable C405.2.3 Daylight zones provided with ❑Complies [EL16]2 individual controls that control the ❑Does Not lights independent of general area ❑Not Observable lighting. ❑Nat Applicable C405.2.3, Primary sidelighted areas are ❑Complies C405.2.3. equipped with required lighting ❑Does Not 1, C405.2.3. controls. ❑ Not Observable 2 ❑Nat Applicable [EL20]1 C405.2.3, Enclosed spaces with daylight area ❑Complies C405.2.3. under skylights and rooftop monitors ❑Does Not 1, are equipped with required lighting ❑Not Observable C405.2.3. 3 controls. ❑Not Applicable [EL21]1 C405.2.4 Separate lighting control devices for ❑Complies [EL4]1 specific uses installed per approved ❑Does Not lighting plans. ❑Not Observable ❑Not Applicable C405.2.4 Additional interior lighting power ❑Complies [EL8]1 allowed for special functions per the ❑Does Not approved lighting plans and is [:]Not Observable automatically controlled and separated from general lighting. ❑Not Applicable C405.3 Exit signs do not exceed 5 watts per ❑Complies [EL6]1 face. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: Comments/Assumptions 11 High Impact (Tier 1) 2 I Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: NOVUS ACADEMY PHASE 1 Report date: 06/06/19 Data filename: S:\2611-001-19 Novus Academy Phase I\COMcheck\2611-001-19 Lighting COMcheck.cck Page 3 of 5 Section I Final Inspection Complies? e.l C303.3, Furnished O&M instructions for ❑Complies C408.2.5. systems and equipment to the ❑Does Not 2 [FI17]3 building owner or designated representative. ❑Not Observable ❑Not Applicable C405.4.1 Interior installed lamp and fixture ❑Complies [F118]1 lighting power is consistent with what ❑Does Not is shown on the approved lighting ❑Nat Observable plans, demonstrating proposed watts ❑Not Applicable are less than or equal to allowed watts. C408.2.5. Furnished as -built drawings for []Complies 1 electric power systems within 90 days ❑Does Not [FI16]3 of system acceptance. ❑Not Observable ❑Not Applicable C408.3 Lighting systems have been tested to ❑Complies [F133]1 ensure proper calibration, adjustment, ❑Does Not programming, and operation. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: Comments/Assumptions See the Interior Lighting fixture schedule for values. 11 High Impact (Tier 1) 1 2 I Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: NOVUS ACADEMY PHASE 1 Report date: 06/06/19 Data filename: S:\2611-001-19 Novus Academy Phase I\COMcheck\2611-001-19 Lighting COMcheck.cck Page 4 of 5 Project Title: NOVUS ACADEMY PHASE 1 Report date: 06/06/19 Data filename: S:\2611-001-19 Novus Academy Phase I\COMcheck\2611-001-19 Lighting COMcheck.cck Page 5 of 5 CAUTION: IF THIS PRINT IS NOT 24" X 36' THEN IT IS A REDUCED PRINT ,i m m r) U-i U LU Novus A cademy Grapevine III 3400 William D. Tate Ave, Suite 1000 Grapevine, TX 76051 G /7'� �i�o it's P�To�e ,<,l� s> l���i��i L.a6� � ,�/��- -- �. a n! ��-- S H-��-T � 1. d / ��rl �'�c /T'�/6�5,�.�J /LG v..1/i.�i�T'�i✓ ALTERNATES ABBREVIATIONS PROJECT CONTACT INFORMATION AL1. CONTRACTOR TO POUR AND FILL CONCRETE IN 1-1/2" DEPRESSED FLOOR. 1 HR. - ONE HOUR A.F.F. - ABOVE FINISHED FLOOR OWNER'S REPRESENTATIVE ADA - AMERICANS WITH DISABILITIES ACT NOVUS ACADEMY ADDL. - ADDITIONAL 204 NORTH DOOLEY ADJ. - ADJUSTABLE GRAPEVINE, TX 76051 AMP - AMPERE PHONE:817.287.9402 ASM - ASSEMBLY CONTACT: KATHY EDWARDS BD. - BOARD BLDG. - BUILDING INTERIOR DESIgNER/ARCHITECT BLKG. - BLOCKING ENTOS DESIGN CAB. - CABINET 5400 LBJ FREEWAY, SUITE 125 CLG - CEILING DALLAS, TEXAS 75240 CLR - CLEAR PHONE:972.770.2222 COL. - COLUMN CONTACT: BARRY MANERS CONTR. - CONTRACTOR CONSTR. - CONSTRUCTION MEP CONSULTANT D - DEPTH AOS ENGINEERING DR - DOOR 5020 TENNYSON PARKWAY DWG - DRAWING PLANO, TEXAS 75024 ELEC - ELECTRICAL PHONE:214.432.3030 EL. - ELEVATION CONTACT: JAKE KING ENGR. - ENGINEER EQ. - EQUAL RAS CONSULTANT ETR - EXISTING TO REMAIN AHSC FE - FIRE EXTINGUISHER 5435 N. GARLAND AVE., STE 140-121 FEC - FIRE EXTINGUISHER CABINET GARLAND, TEXAS 75040 FHC - FIRE HOSE CABINET PHONE: 214.497.0926 FIN. - FINISH CONTACT: DEAN SHINAULT FLUOR - FLUORESCENT GA - GAUGE GC - GENERAL CONTRACTOR GL - GLASS GYP. BD. - GYPSUM BOARD H - HEIGHT HC - HANDICAPPED HM - HOLLOW METAL - _ HORIZ. - HORIZONTAL HDWE - HARDWARE HDWD. - HARDWOOD HVAC - HEATING, VENTILATION & AIR CONDITIONING ITF - INFORMATION TO FOLLOW INSTL. - INSTALLATION MAX - MAXIMUM '- MDF - MEDIUM DENSITY FIBERBOARD MIN - MINIMUM MFG - MANUFACTURER NIC - NOT IN CONTRACT NON. COMB - NON-COMBUSTIBLE NR - NON -RATED NTS - NOT TO SCALE OC - ON CENTER OPNG. - OPENING ORG. - ORGANIC OSHA - -OCCUPATIONAL SAFETY HEALTH ADMINISTRATION PART. - PARTICLE PR. - PAIR - PREFAB. - . PREFABRICATION QTY. - 'QUANTITY REC. - RECESSED REF. - REFERENCE REQD - REQUIRED S.C. - SOLID CORE S.S. - STAINLESS STEEL STD - STANDARD TAS - TEXAS ACCESSIBILITY STANDARDS TBD - TO BE DETERMINED TBS - TO BE SELECTED T-STAT - THERMOSTAT U.N.O. - UNLESS NOTED OTHERWISE V. - VOLTS VERT - VERTICAL VIF - VERIFY IN FIELD V.O.C. - VOLATILE ORGANIC COMPOUND VoIP - VOICE OVER INTERNET PROTOCOL W - WIDTH W/ - WITH WD - WOOD W/O - WITHOUT ;15 i �► [r ..►. �1. w PROJECT DESCRIPTION TENANT IMPROVEMENT SQUARE FOOTAGE: 17,700 S.F. FULLY FIRE SPRINKLERED - YES BUILDING CONSTRUCTION TYPE - TYPE 2B OCCUPANCY GROUP - EDUCATIONAL CURRENT CODES BUILDING FIRE SAFETY MECHANICAL PLUMBING ENERGY ELECTRICAL ACCESSIBILITY - 2006 IBC - 2015 IFC - 2006 IMC - 2006 IPC - 2015 IECC -. 2005 NEC - 2012 TAS PERMIT COMMENTS 1) The plans are made d AS APPROVED and on eeiaject to FIELD NSPEC:MN 1AP'PROVAL. 2) Permit vali tat thall be in accordance with CC fit. t 05,4. 3) APPROVAL b r City Imomtor i." required before cmn„rq _WV vi xk in accord&ca rlith CC Sftt. 109.4. 4) City Inspackr has a► Oho* to make Code; compI notes or marks on approved plans in accordance with 10C Sect. 106.4. 5) Fire Suppression, Alarm Modifications, contact Fire Wki at 817-410.4424 for Plan Review and Inspections. 6) Plans shall comply with regulations of the approved Cond*wmi Use Permit. ANY Changes, Deviations, Deletions or Corrections to the Landscaping, Floor Plans, Elevatiom, Site Plan cw any other Berns shall be presented to the Planning Nii;* nent. 7) ANY merging of two or more suites into one sate twoms electrical service to to combined into one meter, or service. 8) Payment of permit fees and permit issuame are ackvwleftement by applicant of Permit Cornments as Integral to Permit # j�fL ALL EGRESS DOORS KALLt THESE PLANS ARE NOT RI OPENABLE FROM THE INSIDE #THOUT HAND FOR HANDICAPPED ACCE, A KEY OR ANY SPECIAL s IT IS E RESPONSIBILITY - KNOWLEDGE OR EFFORT DESIGN PROFESSIONAL / E MUALLY OPERATED FLUSH BOO AN WNER O A PRO � OBTAIN THEN _ I ARE PROHIBITED STATE AND / OR FEDERAL / Egress Doors Shalt Comply With the ALL CHANGES RE Following Sections of the 2006 IBC APPROVAL Section 1008.1.2 Door swing OF REVISED FL Section 1008.1.3A Access -controlled egress doors Section 1008.1.8 Door operations APPROVED PLANS S �i Section 1008.1.8.1 Hardware KEPT ON JOBS ITE AT AL Section 1008.1.8.3 Locks and latches Section 1008.1.8.4 Bolt locks CONTRACTOR SHALL Section 1008A.8.5 Unlatching INSPECTIONr: Section 1008.t8.6 Delayed egress locks (817) 410-3( 1 Section 1008A.8.7 Stairway doors Section 1008.1.9 Panic and fire exit hardware CONTRACTOR REGIST WILL BE REVOKED L PERMIT EXPIRATIC 10a GGu P C.o�• t�► IEV,.rr A145 PlAe 7449-c zageow *Vs.1i -G. C�Oas ps 1110 01 5400 LBJ Freeway Suite 125 Dallas, Texas 75240 P. 972.770.2222 F. 972.770.2242 www.entosdesign.com ►TE PI.Ii1N�INt1. NIt1CAL, ELiECiW,& AND SIGN PERMi tS &ML 8E REtitJM IEwE6 ;IBILITY D ARc IW4 F THE �� � LDING 'SSARY IPER ENCY �' )DIRE F OF kA i V 06/06/2019 � � "�1t3 tl5tiii�ltli' t�l� BE amw t design professional l contra -L to have plans reviewed and the building TIMES inspwcd by a Certified Energy Code .L FOR flan review and inspwion docimentaticnt showing compliance with the Energy Code acopted by the State shall be submitted the Building Department. **1110 ITION DN > " A W s r� 570 0 For Permit 06/06/2019 For Review 06/03/2019 No. Issued Date Q L Project4� (� Novus Academy o n,. DRAWING INDEX Project ID. 19-1064-Loos Architectural Location G0.01 COVER SHEET G1.01 LIFE SAFETY PLAN Grapevine lll G2.01 GENERAL NOTES G3.01 ACCESSIBILITY STANDARDS n A1.01 PARTITION SECTIONS A1.02 DOOR SCHEDULE 3400 William D. Tate Ave A1.03 NOT USED A2.01 DEMOLITION PLAN Suite 1000 '••+ A3.01 ARCHITECTURAL PLAN Grapevine, Texas 76051 V A4.01 NOT USED ' ••• A5.01 NOT USED E1,01 ELECTRICAL PLAN 11.01 NOT USED Q 12.01 DEMOLITION CEILING PLAN 13.01 REFLECTED CEILING PLAN 14.01 FINISH PLAN (� 15.01 NOT USED 16.01 NOT USED 17.01 NOT USED Sheet Title .� CITY OF GRAPEVINE _ MEP RELEASED FOR CONSTRUCTI(M Cover SheetMEP-1 COVER SHEET SYM N MEP-2 COVER SHEET NOTEOLS SHEET: I an RELEASE DOES NOT AUT11410=1 ANY VOORK IN M-1 DEMOLITION FLOOR PLAN CONFLICT WITH THE BUILDING CODE l ZONING O � M-2 MECHANICAL FLOOR PLANCITY ., CITY APpROV PLA.I� �' , BE K E-1 LIGHTING FLOOR PLAN TIDE JOB SITE AT ALL Mt E-2 POWER FLOOR PLAN DATE: cY: Sheet Number 0 2019 BUILD11143 INSFIIIIIECTION1 $` RELEASE; DOES NOT APPLY io RUCTIOI d EASEMENTS OR PkI RIG -0F•WAY. ALL CHANGES Llt.W B APPROVE Goisol CAUTION: IF THIS PRINT IS NOT 24" X 36" THEN IT IS A REDUCED PRINT hN m m W U W A N m W be w CL Key Plan Scale: 1 /16" = 1'-0" :f 0 4 8 16 NORTH tfr�.• CODE INFORMATION EXIT SEPARATION OCCUPANT MAX. CLASSIFICATION DIAGONAL E OCCUPANCY 168'-10" LEGEND (ALL SYMBOLS MAY NOT APPLY) MIN. ALLOWED ACTUAL EXIT SEPARATION SEPARATION 56'-4" 108'-2" ROOM NUMBER AREA/ROOM INFO. ROOM NAME OCCUPANCY CLASSIFICATION SQ. FT. / LOAD FACTOR OCCUPANT LOAD � � � � � � � 4 TRAVEL DISTANCE PATH -.4111111 >r DEAD END PATH XX' TRAVEL DISTANCE XX, > COMMON PAYH OF EGRESS TRAVEL POINT AND DISTANCE ( XX' ) DEAD END DISTANCE EXIT BUILDING EXIT CEILING MOUNTED EXIT SIGN Imo} WALL MOUNTED EXIT SIGN F. E. FIRE EXTINGUISHER CABINET AA 1313 I AA = SQ. FT, BB = LOAD FACTOR CC I CC = OCCUPANT LOAD DD DD = OCCUPANCY CLASSIFICATION 5400 LBJ Freeway Suite 125 Dallas, Texas 75240 P. 972.770.2222 F. 972.770.2242 www.entosdesign.com For Permit 06/06/2019 For Review 06/03/2019 No. Issued Date Project Novus Academy Project ID: 19-1064-L001 Location Grapevine III 3400 William D. Tate Ave Suite 1000 Grapevine, Texas 76051 Sheet Title Life Safety Plan Sheet Number G1 01 • 02019 r CAUTION: IF THIS PRINT IS NOT 24" X 36' THEN IT IS A REDUCED PRINT m m r) UJ Sz U UJ a PROJECT GENERAL NOTES DEFINITIONS AND ROLES • OWNER'S REPRESENTATIVE: PROPERTY MANAGER/CONSTRUCTION MANAGER (APPROVES DECISIONS AFFECTING COSTS) • OCCUPANT'S REPRESENTATIVE: TENANT OR OCCUPANT'S PROJECT MANAGER • INTERIOR DESIGNER/ARCHITECT: TENANT'S DESIGN REPRESENTATIVE (APPROVES DECISION AFFECTING DESIGN) NOTES TO THE OWNER'S REPRESENTATIVE 1. IF DEMOLITION IS REQUIRED AN ASBESTOS TEST WILL NEED TO BE PROVIDED FOR PERMITTING. NOTES TO OCCUPANT'S REPRESENTATIVE 1. OCCUPANT'S REPRESENTATIVE IS RESPONSIBLE FOR THE FURNISHING AND INSTALLING THE FOLLOWING • PHONE/COMPUTER SYSTEM AND VOICE/DATA CABLING • AUDIO AND VISUAL EQUIPMENT AND WIRING • SECURITY EQUIPMENT, HARDWARE AND WIRING • FURNITURE 2. CHANGES/INFORMATION PROVIDED BY OCCUPANT AFTER ISSUANCE OF CONSTRUCTION DOCUMENTS FOR PERMIT SHALL BE PROVIDED TO ARCHITECT IN A TIMELY MANNER FOR PROPER COORDINATION WITH CONTRACTOR. NOTES TO THE CONTRACTOR REGARDING COORDINATION WITH OWNER'S REPRESENTATIVE 1. THE WORK OF THIS PROJECT SHALL BE COORDINATED WITH THE OWNER'S REPRESENTATIVE. COST SHALL BE SUBMITTED TO THE APPROPRIATE PARTY. 2. CONTACT THE OWNER'S REPRESENTATIVE FOR BUILDING RULES AND REGULATIONS PRIOR TO BID AND FOR A LIST OF "BUILDING STANDARD" ITEMS. 3. COORDINATE WITH THE OWNER'S REPRESENTATIVE THE DISPOSAL OF ITEMS TO BE SALVAGED, STORED AND/OR REUSED ON THE PROJECT PRIOR TO DEMOLITION. 4. COORDINATE WITH OWNER'S REPRESENTATIVE REGARDING SCHEDULING OF CUTTING/CORING OF SLAB, SHOOTING OF TRACK AND OTHER NOISY CONSTRUCTION ACTIVITIES. 5. PRIOR TO ORDERING LOCK SETS, COORDINATE CORE -TYPE WITH THE OWNER'S REPRESENTATIVE. 6. COORDINATE KEYING OF ALL LOCK SETS WITH OCCUPANT'S REPRESENTATIVE AND OWNER'S REPRESENTATIVE. INSTRUCTIONS TO THE CONTRACTOR GENERAL 1. ARCHITECT DOES NOT EXPRESS OR IMPLY WARRANTIES OR GUARANTEES IN REGARDS TO THE INTERPRETATION OR CHANGES TO THE AMERICANS WITH DISABILITIES ACT (ADA) AND TEXAS ACCESSIBILITY STANDARDS (TAS). ARCHITECT HAS DILIGENTLY PROVIDED DOCUMENTS THAT PROVIDE GENERAL COMPLIANCE WITH THE INTENT OF THE ADA AND TAS, HOWEVER, ARCHITECT AND ARCHITECT'S RETAINED CONSULTANTS WILL ASSUME NO LEGAL RESPONSIBILITY FOR THE OUTCOME OF DECISIONS, CONTRACTS, OR COMMITMENTS MADE ON THE BASIS OF THESE DOCUMENTS. G1 SUPPLEMENTAL INSTRUCTIONS G1.1 THE USE OF THE WORD "PROVIDE" IN CONNECTION WITH ANY ITEM SPECIFIED IS INTENDED TO MEAN THAT SUCH SHALL BE FURNISHED, INSTALLED AND CONNECTED. WHERE SO REQUIRED, UNLESS NOTED , OTHERWISE. G1.2 THE TERM "BUILDING STANDARD" AS NOTED ON THE DRAWINGS AND AS SPECIFIED HEREIN, REFERS TO ALL MATERIALS, LABOR, INSTALLATION, ETC. PER OWNER'S REPRESENTATIVE CRITERIA. G2 CONSTRUCTION DOCUMENTS G2.1 ALL DIMENSIONS AND DESCRIPTIONS OF CONSTRUCTION DRAWINGS ARE COMPLIMENTARY. ANY WORK SHOWN OR REFERRED TO ON ANY CONSTRUCTION DOCUMENT SHALL BE PROVIDED AS THOUGH ON ALL RELATED DOCUMENTS. G2.2 ALL CONFLICTS BETWEEN THE ARCHITECTURAL DOCUMENTS AND THE MEP OR OTHER CONSULTANT DOCUMENTS ARE TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF ARCHITECT PRIOR TO CONSTRUCTION AND BIDDING. G2.3 THE WORK DESCRIBED HEREIN SHALL CONFORM TO FEDERAL, STATE AND LOCAL CODES, INCLUDING TEXAS ACCESSIBILITY STANDARDS AND AMERICANS WITH DISABILITIES ACT. G2.4 UNLESS NOTED OTHERWISE, ALL DRAWINGS HAVE BEEN PRODUCED TO SCALE. CONTRACTOR SHALL NOT DIRECTLY MEASURE OR "SCALE" SAID DRAWINGS TO ASCERTAIN DIMENSIONS. G3 CONTRACTUAL RELATIONSHIPS G3.1 NO ITEMS CONTAINED IN THESE DRAWINGS, OR ANY FUTURE CONTRACT DOCUMENTS, SHALL CREATE ANY CONTRACTUAL RELATIONSHIP BETWEEN THE CONTRACTOR AND ARCHITECT. G4 BIDDING G4.1 PROVIDE A COST TO CONSTRUCT THE WORK INDICATED HEREIN. COST SHALL INCLUDE PERMIT, MATERIALS, LABOR (INCLUDING OVERTIME), OVERHEAD, PROFIT AND TAXES. G4.2 PRIOR TO ISSUING THE BID, THE GENERAL CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH ALL EXISTING CONDITIONS AND SYSTEMS. G4.3 ALL REQUESTS FOR INFORMATION (RFI) CONCERNING THE CONSTRUCTION DOCUMENTS SHALL BE DIRECTED TO ARCHITECT IN A WRITTEN FORMAT. G4.4 CONTRACTOR SHALL NOTIFY ARCHITECT IN WRITING PRIOR TO THE BID OF ANY CONCERNS, SHORT -COMINGS OR DISCREPANCIES THAT WOULD RESULT IN A CHANGE ORDER. THE SUBMISSION OF A BID WILL BE UNDERSTOOD AS EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT AND/OR MATERIAL REQUIRED, OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN, WILL NOT BE RECOGNIZED. G4.5 THE CONTRACTOR SHALL EXPRESSLY ACKNOWLEDGE IN WRITING IN THE BID, THAT THEY HAVE READ AND REVIEWED THESE CONSTRUCTION DOCUMENTS IN THEIR ENTIRETY, INCLUDING ALL INFORMATION CONTAINED IN THIS COVERSHEET. G5 SUBSTITUTIONS G5.1 WHERE AN ITEM HAS BEEN SPECIFIED, AN EQUAL OR BETTER PRODUCT OF ANOTHER MANUFACTURER MAY BE USED UPON REVIEW AND WRITTEN ACCEPTANCE BY ARCHITECT. IT IS MANDATORY THAT SUCH REVIEW BE OBTAINED PRIOR TO BIDDING OR THE SUBSTITUTION WILL NOT BE CONSIDERED. ANY SUCH PROPOSED SUBSTITUTION SHALL BE SUBMITTED TO ARCHITECT WITH ALL APPROPRIATE MANUFACTURER'S SAMPLES, DATA AND LITERATURE. ARCHITECT WILL NOTIFY CONTRACTOR IN WRITING AS TO IT'S ACCEPTANCE OR REJECTION. THIS APPLIES ONLY TO ITEMS NOTED AS "OR EQUAL". G5.2 SUBSTITUTIONS MAY BE PRESENTED BY THE CONTRACTOR AS AN ELECTED ALTERNATE FOR APPROVAL BY ARCHITECT. CONTRACTOR SHALL IDENTIFY REASON FOR SUGGESTED ALTERNATE. UNDER NO CONDITION WILL IT BE MANDATORY TO ACCEPT THE ALTERNATE. ARCHITECT WILL NOTIFY CONTRACTOR IN WRITING AS TO ACCEPTANCE OR REJECTION OF ANY ALTERNATE SUBSTITUTION. G6 CONSTRUCTION PROGRESS SCHEDULE G6.1 THE CONTRACTOR SHALL PREPARE AND SUBMIT TO ARCHITECT A WORK SCHEDULE IN A CHART FORMAT. G6.2 CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING INSPECTIONS FOR ALL PHASES OF WORK AS REQUIRED BY FEDERAL, STATE, COUNTY, AND MUNICIPAL LAW, U.N.O. G7 SUBMITTALS G7.1 CONTRACTOR SHALL SUBMIT DETAILED SHOP DRAWINGS AND SUBMITTALS TO THE OWNER'S REPRESENTATIVE AND ARCHITECT AS DETERMINED AT THE BEGINNING OF THE PROJECT. CONTRACTOR SHALL PROVIDE AT LEAST TWO (2) SUBMITTALS OF ALL FINISHES AND SAMPLES SHALL BE 8"X8" MINIMUM AND/OR LARGE ENOUGH TO SEE COMPLETE PATTERN OR REPEAT. G7.2 THE CONTRACTOR SHALL PERFORM NO PORTION OF THE WORK REQUIRING SUBMITTAL REVIEW AND APPROVAL WITHOUT WRITTEN DOCUMENTATION OF APPROVAL BY OWNER'S REPRESENTATIVE. ARCHITECT ACCEPTS NO LIABILITY OF SUCH ITEMS APPROVED BY OTHERS WITHOUT ARCHITECT'S REVIEW. G7.3 THE CONTRACTOR SHALL REVIEW ALL SUBMITTALS PRIOR TO SENDING TO THE OWNER'S REPRESENTATIVE. BY ISSUING THE SUBMITTALS TO THE OWNER'S REPRESENTATIVE, THE CONTRACTOR REPRESENTS THAT HE HAS DETERMINED AND VERIFIED FIELD MEASUREMENTS, FIELD CONSTRUCTION CRITERIA, MATERIALS, CATALOG NUMBERS AND SIMILAR DATA THAT EACH SUBMITTAL IS IN CONFORMANCE WITH THE CONTRACT. G7.4 EACH SUBMITTALS SHALL INCLUDE A TRANSMITTAL WITH CONTRACTOR'S NAME, SUB -CONTRACTOR'S NAME, THE NAME OF THE PROJECT, THE DATE OF SUBMISSION AND THE DATE OF EXPECTED RETURN. IN ADDITION, EACH SUBMITTAL SHALL IDENTIFY THE MANUFACTURER'S NAME, PRODUCT NAME, MODEL NUMBERS, COLORS, ETC. G7.5 THE OWNER'S REPRESENTATIVE WILL REVIEW OR TAKE OTHER APPROPRIATE ACTION UPON THE CONTRACTOR'S SUBMITTALS ONLY FOR THE LIMITED PURPOSE OF CHECKING FOR CONFORMANCE WITH INFORMATION GIVEN AND THE DESIGN CONCEPT EXPRESSED IN THE CONTRACT DOCUMENTS. REVIEW OF SUCH SUBMITTALS IS NOT CONDUCTED FOR THE PURPOSE OF DETERMINING THE ACCURACY AND COMPLETENESS OF OTHER DETAILS SUCH AS DIMENSIONS AND QUANTITIES, OR FOR SUBSTANTIATING INSTRUCTIONS FOR INSTALLATION OR PERFORMANCE OF EQUIPMENT OR SYSTEMS, ALL OF WHICH REMAIN THE RESPONSIBILITY OF THE CONTRACTOR. NOR DOES OCCUPANT REPRESENTATIVE'S REVIEW CONSTITUTE APPROVAL OF SAFETY PRECAUTIONS, OR UNLESS OTHERWISE SPECIFICALLY STATED BY THE OCCUPANT REPRESENTATIVE, OF ANY CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES. THE OCCUPANT REPRESENTATIVE'S APPROVAL OF A SPECIFIC ITEM SHALL NOT INDICATE APPROVAL OF AN ASSEMBLY OF WHICH THE ITEM IS A COMPONENT. G7.6 THE CONTRACTOR SHALL NOT BE RELIEVED OF RESPONSIBILITIES FOR DEVIATIONS FROM REQUIREMENTS OF THE CONTRACT DOCUMENTS BY THE OWNER'S REPRESENTATIVE'S REVIEW OF SHOP DRAWINGS, PRODUCT DATA, SAMPLES OR SIMILAR SUBMITTALS UNLESS THE CONTRACTOR HAS SPECIFICALLY INFORMED THE OCCUPANT'S REPRESENTATIVE, IN WRITING, OF SUCH DEVIATION AT THE TIME OF SUBMITTAL AND THE OCCUPANT'S REPRESENTATIVE HAS GIVEN WRITTEN ACCEPTANCE TO THE SPECIFIC DEVIATION. NOR SHALL THE CONTRACTOR BE RELIEVED OF RESPONSIBILITY FOR ERRORS OR OMISSIONS OF SHOP DRAWINGS, PRODUCT DATA, SAMPLES OR SIMILAR SUBMITTALS BY THE OCCUPANT REPRESENTATIVE'S ACCEPTANCE THEREOF. G8 CLAIMS FOR ADDITIONAL COSTS G8.1 IF THE CONTRACTOR WISHES TO MAKE A CLAIM FOR AN INCREASE IN THE CONTRACT SUM OR TIME, HE SHALL GIVE THE OWNER'S REPRESENTATIVE WRITTEN NOTICE OF SAID OCCURRENCE GIVING RISE TO SUCH A CLAIM. THIS NOTICE SHALL BE APPROVED BY THE OWNER'S REPRESENTATIVE BEFORE PROCEEDING TO EXECUTE THE WORK, EXCEPT IN AN EMERGENCY ENDANGERING LIFE OR PROPERTY. ANY CHANGE IN THE CONTRACT SUM RESULTING FROM CLAIM SHALL BE AUTHORIZED BY A WRITTEN CHANGE ORDER APPROVED BY THE OWNER'S REP. G9 CLARIFICATIONS G9.1 ALL REQUESTS FOR CLARIFICATION OF THE CONSTRUCTION DRAWINGS SHALL BE DIRECTED TO ARCHITECT IN WRITING AND ARCHITECT WILL RESPOND IN THE FORM OF CLARIFICATION DRAWINGS AND/OR WRITTEN CORRESPONDENCE. G10 WORKMANSHIP AND MATERIALS G10.1 ALL WORK SHALL BE DONE IN THE FINEST QUALITY, WORKMANSHIP MANNER IN ACCORDANCE WITH THE INDUSTRY STANDARD FOR CONSTRUCTION, FABRICATION, AND INSTALLATION FOR EACH TRADE, UNLESS OTHERWISE NOTED. USE ONLY NEW AND HIGHEST QUALITY MATERIALS CONSISTENT WITH SPECIFICATIONS INDICATED. G10.2 WORK SHALL INCLUDE ALL LABOR ASSEMBLIES AND FINISH WORK WITH ALL PARTS AND MATERIALS NECESSARY TO MAKE A COMPLETE, IN -PLACE, PROPERLY WORKING AND FINISHED INSTALLATION REGARDLESS IF SHOWN ON DRAWINGS OR NOT. G11 DOCUMENTATION AT SITE G1 1.1 CONTRACTOR SHALL MAINTAIN ON SITE, ONE RECORD COPY OF THE DRAWINGS, SPECIFICATIONS, ADDENDA, CHANGE ORDERS, AND OTHER MODIFICATIONS TO THE CONTRACT DOCUMENTS. ALL MODIFICATIONS ARE TO BE MARKED ON THE RECORD COPY TO ENSURE ALL TRADES ARE AWARE OF ALL CHANGES MADE DURING CONSTRUCTION. G11.2 CONTRACTOR SHALL KEEP ON SITE A COMPLETE SET OF APPROVED SUBMITTALS INCLUDING ALL FINISH SAMPLES. G12 COMPLETION G12.1 WHEN CONTRACTOR IS NEARING COMPLETION, CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE IN WRITING. THE OCCUPANT'S REPRESENTATIVE WILL SCHEDULE A WALK THROUGH TO INSPECT THE PROJECT AREA AND PUNCH LIST OUTLINING INCOMPLETE OR UNACCEPTABLE WORK SHALL BE PREPARED BY THE CONTRACTOR, U.N.O. THE CONTRACTOR SHALL COMPLETE ALL PUNCH LIST ITEMS WITHIN TWO (2) WEEKS OF ISSUANCE OF PUNCH LIST. THE PROJECT WILL NOT BE CONSIDERED COMPLETE UNTIL ALL ITEMS ON THE PUNCH LIST HAVE BEEN RESOLVED AND ALL PROJECT CLOSE OUT DOCUMENTATION HAVE BEEN DELIVERED TO THE OWNER'S REPRESENTATIVE IN THE REQUESTED QUANTITIES. G13 PROJECT CLOSE OUT G13.1 PRIOR TO FINAL APPLICATION FOR PAYMENT OF THE PROJECT, THE CONTRACTOR SHALL ISSUE CLOSEOUT DOCUMENTS. THE CLOSE OUT DOCUMENTATION SHALL INCLUDE THOSE ITEMS SPECIFIED IN THE CONTRACT, BUT A MINIMUM SHALL INCLUDE THOSE LISTED BELOW: - EVIDENCE OF COMPLIANCE WITH REQUIREMENTS OF GOVERNING AUTHORITIES - PROJECT RECORD DOCUMENTS - OPERATION AND MAINTENANCE DATA - WARRANTIES AND BONDS - SPARE PARTS AND MAINTENANCE MATERIALS - KEY AND KEYING SCHEDULE - EVIDENCE OF PAYMENT AND RELEASE OF LIENS - CONSENT OF SURETY AND FINAL PAYMENT - CERTIFICATES OF INSURANCE FOR PRODUCTS AND COMPLETED OPERATIONS - ANY OTHER DOCUMENTS REQUEST BY OWNER'S REPRESENTATIVE G13.2 PRIOR TO FINAL APPLICATION FOR PAYMENT OF THE PROJECT, THE CONTRACTOR SHALL PROVIDE TO THE OWNER'S REPRESENTATIVE, ON BEHALF OF HIMSELF/HERSELF AND HIS/HER RESPECTIVE SUBCONTRACTORS: A ONE (1) YEAR WRITTEN GUARANTEE AGAINST DEFECTIVE WORKMANSHIP AND/OR MATERIALS. THIS WARRANTY SHALL BE IN ADDITION TO (NOT IN LIEU OF) ANY WARRANTIES AND/OR GUARANTEES PROVIDED BY PRODUCT MANUFACTURERS, SUPPLIERS, ETC. PLAN GENERAL NOTES DEMOLITION 1. COORDINATE DEMOLITION PLAN WITH ARCHITECTURAL PLAN INCLUDING ALL GENERAL NOTES, AND PLAN INFORMATION, 2. DEMOLITION IS NOT NECESSARILY LIMITED TO WHAT IS SHOWN, BUT IS TO INCLUDE WHAT IS NECESSARY TO COMPLETE THE WORK IN ACCORDANCE FULL SCOPE OF THESE DOCUMENTS. 3. FURNISH ALL LABOR, MATERIALS & EQUIPMENT TO COMPLETE DEMOLITION AND REMOVAL OF ALL ITEMS AS INDICATED. 4. CONTRACTOR SHALL KEEP ADJACENT AREAS FREE OF DUST AND DEBRIS. 5. UPON DISCOVERY OF CONCEALED OR UNANTICIPATED ITEMS (E.G. ASBESTOS, PLUMBING, DUCTWORK, ETC.) CONTACT THE ARCHITECT PRIOR TO REMOVAL OF SUCH ITEMS. 6. AT THE COMPLETION OF DEMOLITION WORK, THE CONSTRUCTION AREA(S) SHALL BE LEFT IN "BROOM CLEAN" CONDITION. ALL DEBRIS AND MISCELLANEOUS MATERIALS SHALL BE REMOVED. 7. PATCH AND REPAIR ANY DAMAGE CAUSED TO ADJACENT AREAS. 8. AN ACCESSIBLE PATH TO THE EXITS OR FIRE STAIRS SHALL BE MAINTAINED AT ALL TIMES. 9. FIRE RATED WALLS SHALL BE MAINTAINED AT ALL TIMES. IF DAMAGE OR DEMOLITION OF FIRE RATED WALLS OCCUR THEY SHALL BE PROMPTLY REPAIRED, 10. PROTECT EXISTING T-STATS DURING DEMOLITION. 11. NO EXISTING SMOKE DETECTOR, PUBLIC ADDRESS SPEAKER, FIRE ALARM BOX OR SIMILAR DEVICE, INCLUDING THE ASSOCIATED WIRING SHALL BE DAMAGED DURING THE DEMOLITION OR SUBSEQUENT CONSTRUCTION. RELOCATION OF SMOKE DETECTORS, PUBLIC ADDRESS SPEAKERS AND FIRE ALARM EQUIPMENT SHALL BE ACCOMPLISHED AS A FIRST PRIORITY. NO ACTIVE SMOKE DETECTOR SHALL BE LEFT COVERED OR REMOVED. 12. ALL BROKEN, STAINED OR DAMAGED CEILING TILES SHALL BE DISCARDED. 13. REMOVAL OF ANY EQUIPMENT, CABLING, SWITCHES AND CONDUIT PERTAINING TO DATA, COMMUNICATIONS AND TELEPHONES SHALL BE VERIFIED WITH OWNER'S REPRESENTATIVE TO PREVENT CONSTRUCTION DELAYS. 14. REMOVE ALL EXISTING IRREGULAR MATERIALS WHICH MIGHT CAUSE RISE IN FLOORING SURFACE, SUCH AS FASTENERS, OUTLETS, TRIM, FLASH PATCH, CONCRETE FILL, PLYWOOD, ETC., U.N.O. 15. CONTRACTOR TO ENSURE THAT ALL NAILS, SCREWS AND'WALL MOUNTED FIXTURES SHALL BE REMOVED FROM ALL EXISTING WALLS TO REMAIN AND PATCHED AND PREPARED FOR NEW SCHEDULED FINISHES, U.N.O. COORDINATION WITH OWNER'S REPRESENTATIVE 1. CONTRACTOR SHALL COORDINATE WITH THE OWNER'S REPRESENTATIVE ALL ASPECTS OF THE DEMOLITION WORK. 2. COORDINATE THE STORAGE OF SALVAGED MATERIALS, SUCH AS DOORS, FRAMES, HVAC EQUIPMENT, LIGHT FIXTURES, MILLWORK, AND FURNITURE, WITH THE OWNER'S REPRESENTATIVE. 3. COORDINATE DISPOSAL OF SALVAGED ITEMS WITH OWNER'S REPRESENTATIVE. ARCHITECTURAL USE OF PREMISES AND PROTECTION OF PROPERTY 1. CONTRACTOR SHALL CONFINE HIS EQUIPMENT, DELIVERY AND STORAGE OF MATERIALS, AND THE OPERATION OF HIS WORKMEN TO THE LIMITS DEFINED E Y THE OWNER'S REPRESENTATIVE. THE CONTRACTOR SHALL NOT UNREASONABLY ENCUMBER THE PREMISES TO THE INCONVENIENCE OF THE TENANT'S AND OWNER'S PERSONNEL AND OPERATION. 2. CONTRACTOR IS RESPONSIBLE FOR STORAGE OF ALL MATERIALS DURING CONSTRUCTION IN A MANNER THAT PREVENTS LIVE LOADS FROM EXCEEDING THOSE ALLOWED IN THE BUILDING'S STRUCTURAL DESIGN. 3. CONTRACTOR SHALL PROTECT AREA AND NEW OR EXISTING MATERIALS AND FINISHES FROM DAMAGE WHICH MAY OCCUR FROM CONSTRUCTION, DEMOLITION, DUST, WATER, ETC. AND SHALL PROVIDE AND MAINTAIN TEMPORARY BARRICADES, CLOSURE WALLS, ETC. AS REQUIRED TO PROTECT THE PUBLIC DURING THE PERIOD OF CONSTRUCTION. DAMAGE TO NEW AND EXISTING MATERIAL, FINISHES, STRUCTURES, AND EQUIPMENT SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE OWNER'S REPRESENTATIVE AT THE EXPENSE OF THE CONTRACTOR. CONCRETE 1. VERIFY NECESSITY OF X-RAYING SLAB PRIOR TO COMMENCEMENT OF CORING OR CUTTING OF SLAB. REFERENCE ELECTRICAL PLAN. 2. CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY STRUCTURAL OR EQUIPMENT CONFLICTS PRIOR TO CORING/CUTTING OF SLAB. DRYWALL 1. MAINTAIN FIRE RATING WHEN EXISTING PARTITIONS ARE EXTENDED. TAPE, BED, AND TEXTURE 1. TREAT JOINTS AND FASTENERS IN GYP. BOARD IN ACCORDANCE WITH GA-214. 2. LEVEL OF FINISH • LEVEL 0 - NO TAPING OR FINISHING, TEMPORARY CONSTRUCTION • LEVEL 1 - FOR SURFACES IN PLENUM • LEVEL 2 - FOR WATER RESISTANT GYP. BOARD, WAREHOUSE STORAGE • LEVEL 3- FOR HEAVY SPRAY OR TEXTURE IS TO BE USED • LEVEL 4 - FOR FLAT PAINT, LIGHT TEXTURES • LEVEL 5 - FOR HIGH OR SEMI -GLOSS PAINT, NON -TEXTURED FLAT PAINTS AND IN SEVERE LIGHTING CONDITIONS • WALLS RECEIVING WALLCOVERING SHALL BE PREPPED PER THE MANUFACTURER'S RECOMMENDATION CEILING 1. NOTIFY THE ARCHITECT OF ANY CONFLICTS OF LIGHT FIXTURE LOCATION WITH MAIN TEES, DUCTS, STRUCTURE, HVAC, CONDUIT, PIPES, ETC. 2. ALL SWITCHING SHALL COMPLY WITH 2O15 IECC, SECTION C405. 3. PROJECT SHALL USE LIGHTING CONTROLS PER SECTION C405.2. 4. PROJECT SHALL USE OCCUPANCY SENSOR CONTROLS PER SECTION C405.2.1 5. PROJECT SHALL USE LIGHT -REDUCTION CONTROLS PER SECTION C405.2.2.2., C405.2.2.3 6. PROJECT SHALL USE DAYLIGHT RESPONSIVE CONTROLS PER SECTION C405.2.3PROVIDE EXIT SIGNS AND EMERGENCY LIGHTING AS REQUIRED BY CODE. 7. CONTRACTOR SHALL ENSURE THAT CONCEALED J-BOXES ARE ACCESSIBLE. LOCATION OF ACCESS PANELS IN GYP. BD. CEILINGS REQUIRE ARCHITECT'S APPROVAL. 8. CEILING GRID MAIN TEES SHALL NOT BE CUT; SMALL PIECES OF GRID ATTACHED TOGETHER TO FORM ONE LINE IS NOT ACCEPTABLE, SCREWING INTO THE GRID IS NOT ACCEPTABLE AND USE OF CAULK TO SUPPORT SIDE OF CEILING TILE IS NOT ACCEPTABLE. ENSURE LEVEL CEILING THROUGHOUT. FIRE SPRINKLER 1. AUTOMATIC FIRE SPRINKLER EXISTS AND SHALL BE MODIFIED TO CONFOR TO IMPROVEMENTS. ALL SPRINKLER HEADS SHALL MATCH EXISTING HEADS. ALL SPRINKLER HEADS TO HAVE ESCUTCHEONS. FIRE ALARM 1. PROVIDE A FIRE ALARM SYSTEM COMPLETE WITH SPEAKERS AND STROBES TO MEET BUILDING STANDARDS AND CODES. CONNECT ALL SMOKE ALARMS TO BUILDING FIRE ALARM SYSTEM. INCLUDE ALL NECESSARY MODIFICATIONS, EQUIPMENT, TESTING AND RELATED WORK AS REQUIRE FOR THE ADDITIONS AND MODIFICATIONS TO THE BUILDING FIRE ALAR SYSTEM FOR A COMPLETE WORKABLE SYSTEM. ENSURE INSTALLATIO OF SMOKE DETECTOR AT FIRE ALARM PANEL. 2. CENTER STROBES DIRECTLY ABOVE LIGHT SWITCHES, SEE TYPICAL MOUNTING HEIGHTS. FINISH SLAB PREPARATION 1. FLOOR SURFACES SHALL BE INSPECTED BY THE CONTRACTOR. THE ARCHITECT SHALL BE NOTIFIED IF FLOOR LEVELING MUST BE NECESSARY FOR PROPER EXECUTION OF THE WORK. 2. CONCRETE SLABS ON GRADE OR NEW CONCRETE FLOORS SHALL BE TESTED FOR MOISTURE PRIOR TO ORDERING THE FLOORING. CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING IF SLAB FAILS TO MEET THE MOISTURE REQUIREMENTS OF THE MANUFACTURER. GENERAL 1. ALL FINISHES SHALL BE BID AS SPECIFIED. ANY SUBSTITUTION MUST BE APPROVED BY THE ARCHITECT PRIOR TO SUBMISSION OF BID. 2. ALL INTERIOR FINISHES SHALL BE IN COMPLIANCE WITH LOCAL AND NATIONAL CODES. THE CONTRACTOR SHALL ADVISE THE ARCHITECT IMMEDIATELY UPON DISCOVERY OF A NON -COMPLIANT FINISH. 3. ALL FINISHES SHALL BE INSPECTED UPON ARRIVAL TO THE JOB SITE FOR DEFECTS AND DYE LOT CONSISTENCY. NOTIFY ARCHITECT OF ANY DEFECTS PRIOR TO INSTALLATION. THE ARCHITECT SHALL ALSO BE NOTIFIED IMMEDIATELY OF ANY INSTALLATION PROBLEMS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DELIVERY LEAD TIMES FOR ALL FINISHES. ALL DELIVERY TIMES MUST BE CONFIRMED AND ANY FINISHES THAT HAVE EXCESSIVE LEAD TIMES WHEREBY NOT PERMITTING INSTALLATION SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION IMMEDIATELY. 5. ALL FINISHES SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATION. 6. ALL SURFACES SHALL BE PREPARED APPROPRIATELY TO RECEIVE THE SPECIFIED FINISH. ENSURING THAT ALL HOLES, SCRAPES AND GOUGES HAVE BEEN PATCHED AND PREPARED APPROPRIATELY. 7. NONE OF THE FINISHES SHALL BE INSTALLED UNDER CONDITIONS WHICH WOULD JEOPARDIZE THE QUALITY OF THE WORK. ALL WORKMANSHIP WHICH IS JUDGED TO BE LESS THAN FIRST QUALITY BY THE ARCHITECT SHALL BE REJECTED. 8. PROTECT NEW INSTALLED FINISHES FROM DAMAGE THAT MAY OCCUR FROM OTHER TRADES. 9. EXAMINE ALL FINISH SURFACES AFTER COMPLETION OF WORK AND PROCEED WITH TOUCH-UP AS REQUIRED. 10. ALL FINISHES SHALL BE LEFT IN A "LIKE NEW" CONDITION. 11. FINISHES OF THE SAME KIND SHALL ALIGN AND NAP, WEAVE OR PATTERN SHALL RUN IN THE SAME DIRECTION, U.N.O. 12. ALL EXISTING VCT SHALL BE STRIPPED, WAXED, AND BUFFED. FLOORING AND BASE 1. ALL IMPERFECTIONS AND SLIGHT DEPRESSIONS IN THE FLOOR SURFACE SHALL BE SKIM COATED. 2. WHERE FLOOR FINISHES OF DIFFERENT THICKNESS' MEET, FLOOR SHALL BE FILLED TO A MINIMUM SLOPE OF 1" PER V-0" TO ALLOW A SMOOTH TRANSITION. CONTRACTOR TO NOTIFY ARCHITECT AFTER DEMOLITION IF INSTANCE OCCURS FOR DIRECTION OF NEW FLOORING INSTALLATION. 3. WHERE FLOOR FINISHES MEET AT DOORWAYS, TRANSITION OF FINISHES SHALL OCCUR DIRECTLY BENEATH THE CENTER OF THE DOOR LEAF WHEN DOOR IS IN THE CLOSED POSITION, U.N.O. 4. PROVIDE SCHLUTER METAL TRANSITION STRIPS AT DISSIMILAR MATERIALS PER TRANSITION SCHEDULE ON SHEET. 5. NO TRANSITION BETWEEN FLOOR SURFACES SHALL BE GREATER THAN 4', UNLESS BEVELED THEN TRANSITION MAY BE 1 /2" MAX. PAINT 1. PAINT SURFACES PER MANUFACTURER'S RECOMMENDATION, BUT A MINIMUM OF: • 1 COAT OF PRIMER • 2 COATS OF PAINT COORDINATION WITH OCCUPANT'S REPRESENTATIVE 1. CONTRACTOR SHALL SUBMIT SAMPLES OF FINISHES TO OCCUPANT'S REPRESENTATIVE FOR APPROVAL PRIOR TO ORDERING. 2. CONTRACTOR SHALL SCHEDULE A MEETING WITH OCCUPANT'S REPRESENTATIVE TO CONFIRM LOCATIONS OF ATYPICAL FINISHES AND ACCENT PAINTS PRIOR TO ORDERING MATERIAL. �e /. f It'se ELECTRICAL 3. PROVIDE ALL ITEMS NECESSARY PER MANUFACTURER'S RECOMMENDATION TO PROVIDE A COMPLETE, WORKABLE ELECTRICAL SYSTEM PER THE INTENT OF THE CONSTRUCTION DOCUMENTS EVEN THOUGH NOT ALL ITEMS ARE SHOWN ON THE PLANS. 4. NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCY BETWEEN DRAWINGS AND ACTUAL CONDITIONS BEFORE PROCEEDING WITH WORK. 5. PROVIDE POWER TO ALL HVAC AND PLUMING EQUIPMENT PER THE INTENT OF THE CONSTRUCTION DOCUMENTS, EVEN THOUGH NOT ALL ITEMS ARE SHOWN. 6. ALL ABANDONED EQUIPMENT, CONDUIT AND CABLING SHALL BE REMOVED BACK TO SOURCE. 7. ALL RECEPTACLES WITHIN 6' OF "WET' LOCATION SHALL BE "GFI" DEVICES. 8. UPDATE ALL AFFECTED PANEL SCHEDULES IN A TYPE WRITTEN FORMAT. 9. LABEL ELECTRICAL OUTLETS WITH PRINTED TAPED LABEL. 10. EXACT LOCATION OF SPECIAL OUTLETS, INCLUDING, BUT NOT LIMITED TO, FLOOR MOUNTED ELECTRICAL, VOICE/DATA AND TV WALL OUTLETS SHALL BE CONFIRMED WITH THE OCCUPANT'S REPRESENTATIVE PRIOR TO PROCEEDING WITH THE WORK. CONFIRM THE SIZE OF FLOOR CORES TO ACCOMMODATE OCCUPANT'S NEEDS. COORDINATE WITH AN OR DATA CABLING VENDOR. 11. CONTRACTOR TO PROVIDE CONDUIT FOR TELEPHONE, DATA OR ELECTRICAL CABLING THAT PASSES THROUGH ADJACENT SPACES. 12. THE CONTRACTOR SHALL PROVIDE "RING AND STRING" FOR PHONE AND DATA OUTLETS AND COORDINATE ADDITIONAL REQUIREMENTS WITH THE VOICE/DATA CONTRACTOR. za,oG 14. :v- rr ry f 1! ,ova GLU �N iNf �,A,/ �pD(o IPjG Toil el %L e" t-r W1 /Lr ZaoS Al l� JW r %o0, =7 5400 LBJ Freeway Suite 125 Dallas, Texas 75240 P . 972.770.2222 F. 972.770.2242 www.entosdesign.com For Permit 06/06/2019 For Review 06/03/2019 No. Issued Date Project Novus Academy Project ID: 19-1064-L001 Location Grapevine III 3400 William D. Tate Ave Suite 1000 Grapevine, Texas 76051 Sheet Title General Notes Sheet Number G2901 02019 CAUTION: IF THIS PRINT IS NOT 24" X 36" THEN IT IS A REDUCED PRINT MEMBER DEPTH: (EXAMPLE: 6" = 600 X 1 /100 INCHES) ALL MEMBER DEPTHS ARE TAKEN IN 1/100 INCHES FOR ALL "T" SECTIONS MEMBERS DEPTH IS THE INSIDE DIMENSION. STYLE: (EXAMPLE: STUD OR JOIST SECTION = S) FLANGE DEPTH: (EXAMPLE: 2/2' = 2.50" OR 250 X 1 /100 INCHES) MATERIAL THICKNESS: (EXAMPLE: .018 IN. = 18 MILS; 1 MIL =%Doe IN.) MATERIAL THICKNESS IS THE MINIMUM BSE METAL THICKNESS REPRESENTS 95% OF THE DESIGN THICKNESS. INTERIOR NON-STRUCTURAL COMPOSITE: (S) STUD if SPACING 5 PSF MEMBER 2 /2 (IN.) O.C. L/240 250S125-18 12" 10'-6" 6 1250S125-18 16" 9'-7" LO N 250S125-18 24" 8'-3" 2505.125-33.�..�..�....... �.�...�...�..�...�. J 2`'............�..�.....�..1.3'=�' 1I ` .................................................... .............. ...........1 O .250S.1.25-33..........................1.6,.,......... ..........1.2, 0.,...... . 250S125-33 ................................................... 2.4........... ......... ...................... �.0,_6,,...... . 250S 125-43 12" 14'-4" 250S 125-43 16" 13'-0" 250S 125-43 24" 11 '-5" (S) STUDIf SPACING 5 PSF MEMBER 35/ $ (IN.) O.C. L/240 362S 125-18 12" 14'-0" 0 362S 125-18 16" 12'-2" LO 362S 125-18 24" 9'-11 "e ......................................... 362S.1.25-33 ..........................1.2„ . .............. ............................17, ................. 7, ...... O 3Ei2S.1.25-33�..�.....�..�.................�.��� .........:...........16,_��, ..... . 0 `� .................................................. 3625125=33..........................24„ ..................................................... ...................... ......... ..........14,: .............. , ..... . ......... 362S 125-43 12" 19'-2" 362S 125-43 16" 17-5" �02 362S 125-43 24" 15'-3" "e" WEB STIFFENER REQUIRED AT ENDS. (S) STUD 6 SPACING 5 PSF MEMBER (IN.) O.C. L/240 60OS 125-33 12" 26'-2" 600S 125-33 16" 23'-9" 0 600S 125-33 24" 20'-6" . b00S.1.25-43......:..................) . .....................28 _9" ......... . O 6005125-43 .1 .6" ...... 261_ 1,., ......... . .................................................... ...................... . .....1... 4........................24„ .................................................... ............. ..... 22 ,............. . ...................... 600S 125-54 12" 30'-9" Q CD 600S 125-54 16" 27-11 " �2 600S 125-54 24" 24'-5" NOTE: ALL STUD INFORMATION IS BASED ON STEEL STUD MANUFACTURERS ASSOCIATION (SSMA) ICC#ER-4943p. SEE SSMA FOR COMPLETE CHARTS. Limiting Wall Height Table Deflection L/240 �10 m m r) W U W 0 1 r) N m 0 :W h W ry CL 01/A1.01 SEE PLAN � 1 EXTERIOR \ M11111C)N I` 0 Plan Detail @ Mullion 3Scale: 1-1 /2" = 1'-0" 01 /A1.01 _ r SEE PLAN . SILL BELOW EXTERIOR MULLION 0 0 Plan Detail @ Mullionw/ Sill 2Scale: 1-1 /2" = 1'-0" *DO NOT SCREW INTO EXTERIOR MULLION UNDER ANY CIRCUMSTANCES* i- FXTFRIC)R MIII I IC)N 1 /8" NEOPRENE SOUND GASKET, CONTINUOUS UVA i1MA�g321DZ�V Plan Detail @ Mullion Scale: 3" = 1'-0" HEAD CEILING AS SCHEDULED J-MOLD HEAD TRACK, CONTINUOUS 5/8' GYP. BD. EACH SIDE PLAN _ `__----METAL STUD, SEE SPECS FOR GAUGE AND SPACING BASE, SEE FINISH PLAN BASE BASE TRACK, CONTINUOUS V FLOORING, SEE FINISH PLAN REFERENCE LEGEND, SHEET A3.01, FOR SOUND INSULATION REQUIREMENT A3Floor to 3 5/8" STUD NOTES/SPECIFICATIONS DRYWALL AND PARTITIONS 1. STUD SPACING AND GAUGE SHALL BE BASED UPON MANUFACTURER'S ALLOWABLE HEIGHT CHARTS. LIMIT DEFLECTION OF PARTITIONS TO FOLLOWING: - BASED ON 5 PSF UNIFORM DESIGN LOAD - ALL PARTITIONS: L/120 DEFLECTION, - PARTITIONS TO RECEIVE CERAMIC TILE: L/240. 2. NOTIFY ARCHITECT SHOULD PARTITION HEIGHT EXCEED STUD MANUFACTURER'S ALLOWABLE HEIGHT CHART. 3. SOUND BATT INSULATION WHERE SCHEDULED SHALL COMPLY WITH ASTM C 665, TYPE I, GLASS FIBER COMPOSITION, UNFACED. NON-COMBUSTIBLE WHEN TESTED IN ACCORDANCE WITH ASTM E 136. 4. INSTALL PARTITION AND CEILING FRAMING IN ACCORDANCE WITH ASTM C754 AND MANUFACTURER'S INSTRUCTIONS. 5. INSTALL GYPSUM PANELS IN ACCORDANCE WITH ASTM 754, GA-216 AND MANUFACTURER'S INSTRUCTIONS. 6. INSTALL ACOUSTICAL PARTITIONS AS FOLLOWS: • EXTEND ACOUSTICAL PARTITIONS PAST INTERSECTING NON -ACOUSTICAL PARTITIONS. • FILL WALL CAVITY WITH SOUND BATTS. ELIMINATE ALL VOIDS. • SEAL ACOUSTICAL PARTITION AT PERIMETER AND/OR AROUND PENETRATIONS WITH CONTINUOUS BEAD OF SEALER. IN FIRE RATED PARTITIONS, USE FIRE STOPPING SEALER. IN ACOUSTICAL PARTITIONS, USE ACOUSTICAL SEALER. SEAL SPACE BETWEEN GYP. BOARD PANEL AT CONTROL JOINTS, PRIOR TO INSTALLING METAL CONTROL JOINTS. 7. INSTALL ACCESSORIES AS FOLLOWS: • INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. • INSTALL CORNER REINFORCEMENT AT OUTSIDE CORNERS. • USE SINGLE LENGTHS WHERE LENGTH OF CORNER DOES NOT EXCEED STANDARD HEIGHT. • INSTALL CONTROL JOINTS AT FULL HEIGHT PARTITIONS AT MAXIMUM OF 30' APART. CONTROL JOINTS MAY BE INSTALLED AT BOTH SIDES OF THE DOOR HEADER. • INSTALL CONTROL JOINT IN GYP. BOARD CEILING AT MAXIMUM OF 50' OR MAXIMUM OF 2500 S.F. 8. FOR PARTITIONS UNDER 10'-0" HIGH OR LESS, USE VERTICAL INSTALLATION OR PARTITIONS OVER 10'-0" HIGH USE HORIZONTAL INSTALLATION AND STAGGERED PANELS. 9. PROVIDE BRACING ABOVE CEILING WHEN LONG UNBRACED WALL LENGTHS OCCUR AND AT ALL DOOR AN[) GLAZED OPENINGS. 10. PROVIDE ACCESS PANELS OF THE APPROPRIATE FIRE RATING FOR MECHANICAL, ELECTRICAL OR PLUMBING ACCESS. 11. USE REGULAR PAPER FACED GYPSUM BOARD FOR TYPICAL PARTITION CONSTRUCTION. 12. USE TYPE 'X' GYPSUM BOARD AT FIRE RATED PARTITIONS. 13. USE MOISTURE RESISTANT GYPSUM BOARD BEHIND TOILETS, LAVATORIES AND URINALS. ALSO USE IT IN ROOMS WITH HIGH HUMIDITY. 14. USE CEMENT BOARD AT SHOWERS. 15. USE IMPACT RESISTANT GYPSUM BOARD IN LOADING DOCKS, FREIGHT ELEVATOR LOBBIES AND DELIVERY CORRIDORS. PARTITION LAYOUT l . PARTITIONS ARE TO THE CENTERLINE OF THE MULLION, U.N.O. 2. DIMENSIONS, LOCATING DOORS, ARE TO THE INSIDE FACE OF THE JAMB, U.N.O. 3. ALL DIMENSIONS ARE FROM FINISHED FAQ_E TO FINISHED FACE, U.N.O. 4. PARTITION LAYOUT SHALL BE APPROVED �Y THE OCCUPANT'S REPRESENTATIVE. 5. IF LAYOUT IS OFF BY MORE THAN 3", NOTIFY ARCHITECT. ROUGH BLOCKING 1. PROVIDE BLOCKING, NAILERS, GROUNDS, FURRING AND OTHER SIMILAR ITEMS REQUIRED TO RECEIVE AND SUPPORT MILLWORK AND OTHER WALL MOUNTED EQUIPMENT. 2. FIRE RETARDANT WOOD SHALL BE BE USED AS REQUIRED BY IBC 603.1 5400 LBJ Freeway Suite 125 Dallas, Texas 75240 P. 972.770.2222 F. 972.770.2242 www.entosdesign.com For Permit 06/06/2019 For Review 06/03/2019 No. Issued Date Project Novus Academy Project ID: 19-1064-L001 Location Grapevine III 3400 William D. Tate Ave Suite 1000 Grapevine, Texas 76051 Sheet Title Partition Sections Sheet Number c0 2019 Al 001 CAUTION: IF THIS PRINT IS NOT 24" X 36" THEN IT IS A REDUCED PRINT DOOR SCHEDULE DOOR FRAME HDWE MARK RATING TYPE LEAF WIDTH LEAF HEIGHT TYPE FINISH TYPE MATERIAL FINISH 109 3-0" 8'-10" - - - - - 1 - 110 3'-0" 8'-10" - - - - - 1 - 112 3'-0" 8'-10" - - - - - 1 - 115 3'-0" 8'-10" - - - - - 1 116 3'-0" 8'-10" - - - - - 1 - 117 3'-0" 8'-10" - - - - - 1 - 120 3'-0" 8'-10" - - - - - 2 - 124 3'-0" 8'-10" - - - - - 1 - 127 3'-0"; 3'-0" 8'-10" - - - - - 1 - 128 3'-0" 8'-10" - - - - - 1 - 129 3'-0" 8'-10" - - - - - 1 - 130 3'-0" 8'-10" - - - - - 1 - 131 3-0" 8'-10" - - - - - 1 - 132 3'-0" 8'-101, - - - - - 1 - HARDWARE - *ALL ITEMS MAY NOT APPLY SET #E EXISTING HARDWARE TO REMAIN REPAIR AS REQUIRED TO BRING TO "LIKE NEW" CONDITION SET #1 LOCK SET W/ CLOSER - OFFICE • HINGES • LOCK FUNCTION LEVER HARDWARE SET • CLOSER • SILENCERS • DOOR STOP SET #2 PANIC HARDWARE W/ OVERHEAD CLOSER • HINGES • PANIC HARDWARE SET • OVERHEAD CLOSER • DOOR STOP W- �� m m r) LU r� V LU ri, u COMMENTS REUSE BUILDING DOOR, FRAME, SIDELIGHT, & LEVER HARDWARE REUSE BUILDING DOOR, FRAME, SIDELIGHT, & LEVER HARDWARE REUSE BUILDING DOOR, FRAME, SIDELIGHT, & LEVER HARDWARE REUSE BUILDING DOOR, FRAME, SIDELIGHT, & LEVER HARDWARE REUSE BUILDING DOOR, FRAME, SIDELIGHT, & LEVER HARDWARE REUSE BUILDING DOOR, FRAME, SIDELIGHT, & LEVER HARDWARE REUSE DOOR & FRAME REUSE BUILDING LEVER HARDWARE REUSE DOUBLE DOOR, FRAME, & PANIC HARDWARE REUSE BUILDING DOOR, SIDELIGHT, & LEVER HARDWARE REUSE BUILDING DOOR, SIDELIGHT, & LEVER HARDWARE REUSE BUILDING DOOR, SIDELIGHT, & LEVER HARDWARE REUSE BUILDING DOOR, SIDELIGHT, & LEVER HARDWARE REUSE BUILDING DOOR, SIDELIGHT, & LEVER HARDWARE ALL EGRESS DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT MANUALLY OPERATED FLUSH BOLTS ARE PROHIBITED Egre 000r$ shall compi Vv�i r�o of the I �'©1IOWit1g S�00. Section 1008.1.2 Door I0 09 Section 100813.4 Acoesvc;»►t1 - , -r" section1008,118 Dooroperad Section 10081" 1Iar . WA`.# Section 10081,8,8 ia> e Section 100g;L8.4 Solt locks Section 100's us'-s unlatolu 100$.1.&6 ways ogr'eP section Se4don100.8.1.S7 Stairway doors scion 1008.1.91'anjc and fke euit hard' [E]EXISTING TO REMAIN Ifl SOLID CORE, FLUSH PANEL WOOD SINGLE DOOR FE] EXISTING TO REMAIN F STANDARD DOOR FRAME NOTES DOORS 1. INSTALL DOORS PLUMB AND LEVEL. 2. PROVIDE A 1 /2" UNDERCUT MAXIMUM. 3. ENSURE DOORS OPERATE FREELY. MAXIMUM DIAGONAL TOLERANCE 1 /4" MEASURED WITH STRAIGHT EDGE FROM CORNER TO CORNER. 4. WOOD VENEER FACED DOORS TO MEET AWI PREMIUM QUALITY WITH BOOK MATCHED GRAIN, END MATCHED TRANSOMS, SPECIES AND CUT TO MATCH "BUILDING STANDARD", U.N.O. DOOR FRAMES 1. FABRICATE FRAME TO PERMIT INSTALLATION OVER METAL STUD PARTITIONS FACED WITH GYP. BD. 2. FRAME FASTENERS SHALL NOT BE EXPOSED. 3. PROVIDE INTERNAL REINFORCEMENT FOR DOOR HARDWARE. 4. SET FRAMES PLUMB AND LEVEL, FREE FROM WARP OR TWIST. 5. RIGIDLY ATTACH USING FASTENERS OR TYPE BEST SUITED TO APPLICATION. 6. FIT CORNER AND INTERSECTIONS TO BE FLUSH WITH HAIRLINE JOINTS. DOOR HARDWARE 1. ALL NEW PASSAGE/LOCK SETS SHALL BE LEVERS AND ACCESSIBILITY CODE COMPLIANT. 2. INSTALL HARDWARE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 3. INSTALL LOCK SETS, CLOSERS AND TRIM AFTER FINISH PAINTING/STAINING. 4. LOCATE ITEMS IN ACCORDANCE WITH BHMA RECOMMENDATIONS, UNLESS NOTED OTHERWISE. 5. TEST AND ADJUST HARDWARE FOR QUIET, SMOOTH OPERATION, FREE OF STICKING, BINDING AND RATTLING. 6. MOUNT CLOSER SO THAT CLOSER AND CLOSER ARM ARE NOT VISIBLE ON CORRIDOR SIDE. 7. ADJUST DOOR CLOSER TO OPERATE DOOR IN ACCORDANCE WITH THE "ACCESSIBLE DOOR INSTALLATION GUIDE" NOTATIONS. 8. PROVIDE THE APPROPRIATE NUMBER OF BUTTS FOR EACH DOOR. 9. PROVIDE BALL BEARING HINGES AT FIRE RATED DOORS AND AT ALL DOORS OVER 3' WIDE . 10. DOUBLE DOORS AT FIRE RATED WALLS SHALL RECEIVE DOOR COORDINATOR (BAR) CLOSER AT BOTH DOORS, ASTRAGAL MOUNTED ON ACTIVE LEAF AND CONCEALED AUTOMATIC FLUSH BOLTS INSTALLED ON INACTIVE LEAF, UNO. 11. DOOR CLOSERS AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 900 THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 ° FROM THE LATCH IS 5 SECONDS MINIMUM. 12. FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: • INTERIOR HINGED DOORS AND GATES: 5 POUNDS (22.2 N) MAXIMUM. • SLIDING OR FOLDING DOORS: 5 POUNDS (22.2 N) MAXIMUM. THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR OR GATE IN A CLOSED POSITION. 13. FINISH OF HARDWARE TO COORDINATE WITH TRIM FINISH. 14. HINGES - PROVIDE APPROPRIATE QUANTITY FOR DOOR SPEC. SPECIFICATIONS * REFER SHEET A1.03 FOR ALL GLASS DOOR SPECIFICATIONS *ALL ITEMS MAY NOT APPLY DOOR *ALL NEW DOORS WILL BE PROVIDED BY BUILDING OWNER. DOOR FINISH STAIN MATCH BUILDING STANDARD FRAME * ALL NEW FRAMES WILL BE PROVIDED BY BUILDING OWNER. HARDWARE *ALL NEW HARDWARE WILL BE PROVIDED BY BUILDING OWNER. LEVER SET FULL MORTISE DOOR STOP PROVIDE (1) PER DOOR, FLOOR MATCH BUILDING STANDARD REFER TO GLAZING TYPES 1:fl INTEGRATED DOOR/SIDELIGHT FRAME Solid Door Types Frame Types Not To Scale Not To Scale .j T U "c%) �< O Lever Set Door/Hardware Placement Not To Scale 5400 LBJ Freeway Suite 125 Dallas, Texas 75240 P. 972.770.2222 F. 972.770.2242 www.entosdesign.com For Permit 06/06/2019 For Review 06/03/2019 No. Issued Date Project Novus Academy Project ID: 19-1064-L001 Location Grapevine III 3400 William D. Tate Ave Suite 1000 Grapevine, Texas 76051 Sheet Title Door Schedule & Glazing Type Sheet Number 0 2019 m m r) LJJ U LU M 11 Db � F.E.C.rn „ J D3 C) C F. E.C. EG F.E.C. Y --------------- D6 D9 D6 I ,X - 'S�r (*) D4 N 1 - -- Demolition Plan NORTH Scale: 1 /8" = 1'-0" 0 2 4 8 CAUTION: IF THIS PRINT IS NOT 24" X 36" THEN IT IS A REDUCED PRINT NOTES PLAN NOTES 1. REMOVE ALL FINISHES (FLOORING, BASE AND WALLCOVERING) FOR PROPER INSTALLATION OF NEW FINISHES SPECIFIED ON FINISH PLAN, U.N.O. 2. REMOVE WALLS AND OTHER ITEMS (INCLUDING, BUT NOT LIMITED TO DOORS/FRAMES, GLAZING AND MILLWORK) AS INDICATED ON PLAN. 3. SEE MEP ENGINEERING DRAWINGS FOR SCOPE OF DEMOLITION. KEY NOTES D1. REMOVE AND RELOCATE DOUBLE DOOR. SEE SHEET A3.01 FOR LOCATION. D2. REMOVE DOUBLE DOOR AND PATCH WALL. SALVAGE AND RETURN TO BUILDING. D3. REMOVE WINDOW AND PATCH WALL. SALVAGE WINDOW AND RETURN TO BUILDING. D4. REMOVE AND CAP FLOOR OUTLET. D5. REMOVE AND DISPOSE ELECTRICAL OUTLET. D6. VCT FLOOR TO REMAIN. CONTRACTOR TO STRIP, WAX, AND BUFF FLOOR. D7. PORCELAIN TILE FLOOR TO REMAIN. D8. CARPET FLOOR TO REMAIN. D9. REMOVE CARPET. D10. REMOVE AND REUSE DOOR. REMOVE LEVER HARDWARE AND RETURN IT TO BUILDING. INSTALL PANIC HARDWARE TO MATCH BUILDING STANDARD. SEE SHEET A3.01 FOR LOCATION. D1 1. CONCRETE TO REMAIN. LEGEND (ALL SYMBOLS MAY NOT APPLY) *EXISTING TO REMAIN ITEMS ARE SCREENED (GRAYED OUT)* GENERAL EXISTING PARTITION TO REMAIN _ _ = DEMOLISHED ITEMS SIDELIGHT/WINDOW EXISTING DOOR TO REMAIN is DEMOLITION OUTLETS J DEMOLISHED FLOOR OUTLET DEMOLISHED POWER POLE Z FINISH TRANSITION 5400 LBJ Freeway Suite 125 Dallas, Texas 75240 P. 972.770.2222 F. 972.770.2242 www.entosdesign.com For Permit 06/06/2019 For Review 06/03/2019 No. Issued Date Project Novus Academy Project ID: 19-1064-L001 Location Grapevine III 3400 William D. Tate Ave Suite 1000 Grapevine, Texas 76051 Sheet Title Demolition Plan Sheet Number 0 2019 Demolition Plan NORTH Scale: 1 /8" = 1'-0" 0 2 4 8 CAUTION: IF THIS PRINT IS NOT 24" X 36" THEN IT IS A REDUCED PRINT NOTES PLAN NOTES 1. REMOVE ALL FINISHES (FLOORING, BASE AND WALLCOVERING) FOR PROPER INSTALLATION OF NEW FINISHES SPECIFIED ON FINISH PLAN, U.N.O. 2. REMOVE WALLS AND OTHER ITEMS (INCLUDING, BUT NOT LIMITED TO DOORS/FRAMES, GLAZING AND MILLWORK) AS INDICATED ON PLAN. 3. SEE MEP ENGINEERING DRAWINGS FOR SCOPE OF DEMOLITION. KEY NOTES D1. REMOVE AND RELOCATE DOUBLE DOOR. SEE SHEET A3.01 FOR LOCATION. D2. REMOVE DOUBLE DOOR AND PATCH WALL. SALVAGE AND RETURN TO BUILDING. D3. REMOVE WINDOW AND PATCH WALL. SALVAGE WINDOW AND RETURN TO BUILDING. D4. REMOVE AND CAP FLOOR OUTLET. D5. REMOVE AND DISPOSE ELECTRICAL OUTLET. D6. VCT FLOOR TO REMAIN. CONTRACTOR TO STRIP, WAX, AND BUFF FLOOR. D7. PORCELAIN TILE FLOOR TO REMAIN. D8. CARPET FLOOR TO REMAIN. D9. REMOVE CARPET. D10. REMOVE AND REUSE DOOR. REMOVE LEVER HARDWARE AND RETURN IT TO BUILDING. INSTALL PANIC HARDWARE TO MATCH BUILDING STANDARD. SEE SHEET A3.01 FOR LOCATION. D1 1. CONCRETE TO REMAIN. LEGEND (ALL SYMBOLS MAY NOT APPLY) *EXISTING TO REMAIN ITEMS ARE SCREENED (GRAYED OUT)* GENERAL EXISTING PARTITION TO REMAIN _ _ = DEMOLISHED ITEMS SIDELIGHT/WINDOW EXISTING DOOR TO REMAIN is DEMOLITION OUTLETS J DEMOLISHED FLOOR OUTLET DEMOLISHED POWER POLE Z FINISH TRANSITION 5400 LBJ Freeway Suite 125 Dallas, Texas 75240 P. 972.770.2222 F. 972.770.2242 www.entosdesign.com For Permit 06/06/2019 For Review 06/03/2019 No. Issued Date Project Novus Academy Project ID: 19-1064-L001 Location Grapevine III 3400 William D. Tate Ave Suite 1000 Grapevine, Texas 76051 Sheet Title Demolition Plan Sheet Number 0 2019 m m n w U w 'i' u 128 OFFICE a� 16'-10" ..� 126 BACK EXIT 125 OFFICE ~ 124 OFFICE 1124 123 OFFICE A3 527 .E.C. ALIGN u '3 127 CORR. 132 133 00 e 134 132 MEN WOMEN CLASSROOM (30 o I � U 104 COMMONS 105 COMMONS 5 NORTH Architectural Plan Scale: 1 /8" = 1`-0" 0 2 4 8 CAUTION: IF THIS PRINT IS NOT 24" X 36" THEN IT IS A REDUCED PRINT 5400 LBJ Freeway Suite 125 Dallas, Texas 75240 P. 972.770.2222 F. 972.770.2242 www.entosdesign.com For Permit 06/06/2019 For Review 06/03/2019 No. Issued Date Project Novus Academy Project ID: 19-1064-L001 Location Grapevine III 3400 William D. Tate Ave Suite 1000 Grapevine, Texas 76051 Sheet Title Architectural Plan Sheet Number 02019 A3,sOl CAUTION: IF THIS PRINT IS NOT 24" X 36" THEN IT IS A REDUCED PRINT J 128 OFFICE db ttY }0+48 F.E.C. . •I — 126 4 BACK EXIT 127 CORR. fl 0 FF Q CR O MEN `� WOMEN .0 +9'-0" 132 Q S CLASSROOM 00 00 ,kzjk p arm (p (DF.E:G. CR 119 COMMONS .l �, vvvvv —vvvv �,. 117 116 CLASSROOM 09. CLASSROOM 114 113 118 � COPY ® STOR. THERAPY OFFICE r�—i W 115 CLASSROOM 104 COMMONS 112 CLASSROOM T rn(i C� 105 COMMONS 0 5400 LBJ Freeway Suite 125 Dallas, Texas 75240 P. 972.770.2222 F. 972.770.2242 www.entosdesign.com For Permit 06/06/2019 For Review 06/03/2019 No. Issued Date Project Novus Academy Project ID: 19-1064-L001 Location Grapevine III 3400 William D. Tate Ave Suite 1000 Grapevine, Texas 76051 Sheet Title Electrical Plan Electrical Plan 00=6iiiiiiiiiiiii NORTH Scale: 1 /8" = 1'-0" 0 2 4 8 Sheet Number 0 2019 El • CAUTION: IF THIS PRINT 1S NOT 24" X 36' THEN IT IS A REDUCED PRINT o ----' .I }1 � O DCl O DCl CC21 tT - [ Cl O Cl O DC3 O D 1 T- I ---- 0� <) CC1 I Fr- 0 1 1 0 1 1 n 1 1 0 I 1 0 _ 1F 0 0 i i I 1 I_- 1 I 0 i E m m w U w N 0 UJ r w rV IL I� (DC1 1 � f ®} DCl O O(7C1 O DCl <� O iv IDCI DCl O `DC4 O I DC3` I -- — LN .I I 1 Lio(@ DCl OL I I .I� i N �I II 0 f®f DCl f(V � i 0 O 1 O CCI CC1 O 1 O CCl DC4 01 c1 Demolition Ceiling Plan �- NORTH Scale: 1 /8" = V-0" 0 2 4 8 5400 LBJ Freeway Suite 125 Dallas, Texas 75240 P. 972.770.2222 F. 972.770.2242 www.entosdesign.com For Permit 06/06/2019 For Review 06/03/2019 No. Issued Date Project Novus Academy Project ID: 19-1064-L001 Location Grapevine III 3400 William D. Tate Ave Suite 1000 Grapevine, Texas 76051 Sheet Title Demolition Ceiling Plan Sheet Number 12001 0 2019 CAUTION: IF THIS PRINT IS NOT 24" X 36' THEN IT IS A REDUCED PRINT NOTES PLAN NOTES 1. NEW FIRE RATED PARTITIONS SHALL HAVE FIRE/SMOKE DAMPERS OF THE APPROPRIATE SIZE AND RATING. 2. EXISTING CEILING GRID SHALL REMAIN, U.N.O. RELEVEL GRID WHERE NEEDED. CAULK HOLES AND TOUCH-UP PAINT SCRATCHES AT MAIN TEES. REPLACE DAMAGED CROSS TEES. I 3. EXISTING CEILING TILE SHALL REMAIN, U.N.O. REPLACE DAMAGED/STAINED TILES AS NEEDED. RELOCATE OLD TILE IN SAME ROOM(S). COORDINATE LOCATION OF OLD TILE WITH OCCUPANT'S REPRESENTATIVE. 4. EXISTING LIGHT FIXTURES/EXIT SIGNS SHALL REMAIN, U.N.O. CLEAN, REPLACE BAD BALLASTS, DIM AND BURNED OUT LAMPS. ENSURE LAMP COLOR AND WATTAGE IS CONSISTENT WITHIN THE LEASE SPACE. 5. PROVIDE NEW LIGHT FIXTURES/EXIT SIGNS AS SHOWN ON PLAN. 6. RELOCATE T-STATS, DIFFUSER AND RETURNS, AND PROVIDE NEW SUPPLY DUCT, DIFFUSERS AND RETURNS AS NEEDED FOR OCCUPANT COMFORT. CONTRACTOR TO TAKE INVENTORY OF MISSING ITEMS CEILING ITEMS (INCLUDING DIFFUSERS, RETURNS, ETC) AND PROVIDE NEW TO I, MATCH EXISTING AS NECESSARY. 8. NG, MODIALL DFYOFIREDAI ARM SOYSTEMLES O PER JOINTS IN DUCTWORK. I ! I f 7 PATCH 9. EMERGENCY LIGHTING AND EXIT SI GNAGE I S BE PROVIDED BY LIFE SAFETY HALL J GENERATOR/BATTERY PACK. rI — 10. REFERENCE MEP DRAWING IN CONJUNCTION WITH ARCHITECTURAL PLANS AND !.� COORDINATE WORK TO INCLUDE REQUIREMENTS OF BOTH DISCIPLINES. NOTIFY ARCHITECT _ + _ - OF ANY CONFLICTS OR CONTRADICTIONS PRIOR TO INSTALLATION. ANY WORK DONE PRIOR t _PJJ iCJM I CjRGGM C „ , _ �, TO CLARIFICATION THAT RESULTS IN THE NEED FOR MODIFICATION WILL BE THE SOLE + + 0'-5 x 9'-8 ± 8'-0" x 9'-8"+ O 23'-8 x 19 -8' _ 2C'-5 x 15 -8' � a� ® i — R MECHANICAL SROOM �. { MEN O ! o 1 WOMEN O Al .5 X 0 I A -_F_ —.- JAN.: N.I.C. I - -I HE AP" O FI -----°I `—.`"' "— STOF E _ C OPY ( J I - I CEILING ELECTRICAL Q BOX IN CEILING LIGHT SWITCHING VACANCY SENSORJ it CEILING MOUNTED DUPLEX LOW VOLTAGE . PI ■ I ry CEILING MOUNTED TV OUTLET DIMMER W/ SLIDE I � (R) (R) I, ( 3-WAY OCCUPANT SENSOR PROJECTION SCREEN �r..,,I 101 L ��.. I(R) M f CLA>SROOiA 6 CLASSR t: 19'-7' x 17'-1 )"± 19'-7" X i (R) (R) Reflected Ceiling flan NORTH Scale: 1 /8" = 1'-0" 0 2 4 8 5400 LBJ Freeway Suite 125 Dallas, Texas 75240 P. 972.770.2222 F. 972.770.2242 www.entosdesign.com For Permit 06/06/2019 For Review 06/03/2019 No. Issued Date Project Novus Academy Project ID: 19-1064-L001 Location Grapevine III 3400 William D. Tate Ave Suite 1000 Grapevine, Texas 76051 Sheet Title Reflected Ceiling Plan Sheet Number © 2019 'i, VCT-E 125 OFFICE 124 OFFICE VP-1 123 OFFICE CPT-E r L— _ 128 OFFICE " CPT-1 Finish Plan Scale: 1 /8" = V-0" VCT-E 126 BACK EXIT rvvvyv 132 CLASSROOM > of IF- 120 VCT-E CORR. F.E.C. VP-1 119 COMMONS 117 CLASSROOM CPT-1 VP-1 127 CORR. . I I M t T E T-E C) C TB-E T-E 133 C) C 134 MEN WOMEN C) 0 PT-1 F.E.C. CPT-E 118 THERAPY OFFICE 116 CLASSROC CPT-1 111 CORR. ------------- -- CPT-E 114 113 COPY STOR. VP-1 r 115 .ASSROOM CPT-1 MC7' 104 COMMONS 112 CLASSROOM CPT-1 105 COMMONS VP-1 0 107 COMMONS 110 L. CLASSROOM CPT-1 1 0 2 4 8 NORTH 5400 LBJ Freeway Suite 125 Dallas, Texas 75240 P. 972.770.2222 F. 972.770.2242 www.entosdesign.com For Permit 06/06/2019 For Review 06/03/2019 No. Issued Date .rani Novus Academy Project ID: 19-1064-L001 Location Grapevine Ill 3400 William D. Tate Ave Suite 1000 Grapevine, Texas 76051 Sheet Title Finish Plan Sheet Number 0 2019 14001 MECHANICAL PIPING DESIGNATIONS EQUIPMENT DESIGNATIONS ABBREVIATIONS AND SYMBOLS PLUMBING PIPING SYMBOLS PIPING DESIGNATIONS ALL SYMBOLS MAY NOT APPEAR ON DRAWINGS. ELECTRICAL POWER SYMBOLS ABBREVIATIONS CHS CHILLED WATER SUPPLY AC AIR COMPRESSOR fl PIPING UP EXISTING TO REMAIN GENERAL PURPOSE RECEPTACLE CHR CHILLED WATER RETURN AF AIR FILTER PIPING DOWN --------- EXISTING TO BE REMOVED/DEMOLISHED XX=HEIGHT ABOVE FINISHED FLOOR CWS CONDENSER WATER SUPPLY AH/AHU AIR HANDLING UNIT CAPPED PIPE TERMINATION - — DOMESTIC COLD WATER FLOOR GENERAL PURPOSE RECEPTACLE CWR CONDENSER WATER RETURN AS AIR SEPARATOR CONNECTION BOTTOM OF MAIN — - - - DOMESTIC HOT WATER CEILING GENERAL PURPOSE RECEPTACLE HWS HEATING WATER SUPPLY BF BOOSTER FAN -O--01- CONNECTION TOP OF MAIN — - - - DOMESTIC HOT WATER RETURN 4) GFI RECEPTACLE HWR HEATING WATER RETURN CP CIRCULATING PUMP DIRECTION OF FLOW F FIRE PROTECTION {) 1/2 SWITCHED RECEPTACLE HPWS HEAT PUMP WATER SUPPLY CRAC COMPUTER ROOM AIR CONDITIONER SLOPE DOWN IN DIRECTION SHOWN G NATURAL GAS QUADRAPLEX RECEPTACLE HPWR HEAT PUMP WATER RETURN CT COOLING TOWER --D— CONCENTRIC REDUCER W WATER SERVICE FLOOR QUADRAPLEX RECEPTACLE E EXPANSION LINE CU CONDENSING UNIT, AIR COOED ECCENTRIC REDUCER A COMPRESSED AIR CEILING QUADRAPLEX RECEPTACLE CD CONDENSATE DRAIN CVT CONSTANT VOLUME FAN TERMINAL COOL/HEAT 04'— GATE VALVE V VACUUM � BALL VALVE � USB/DUPLEX RECEPTACLE EDH ELECTRIC DUCT HEATER D �— INDIRECT WASTE EF EXHAUST FAN BUTTERFLY VALVE SS SANITARY SEWER ® SPECIAL RECEPTACLE EUH ELECTRIC UNIT HEATER 084— GLOBE VALVE _ _ _ SANITARY VENT TELEVISION OUTLET MECHANICAL SYMBOLS FCU FAN COIL UNIT TEMPERATURE & PRESSURE RELIEF VALVE RD PRIMARY ROOF DRAIN ♦ TELEPHONE OUTLET NEW FAN POWERED BOX FD FPB FIRE DAMPER FAN POWERED BOX 4— GAS COCK PRESSURE REGULATING VALVE OD SD OVERFLOW ROOF DRAIN STORM DRAIN 111T,11 � FLOOR TELEPHONE OUTLET CEILING TELEPHONE OUTLET EXISTING FAN POWERED BOX FSD FIRE/SMOKE COMBINATION DAMPER � CHECK VALVE SSD BELOW GRADE SUB -SOIL DRAIN p DATA OUTLET HYDRAULIC SHOCK ARRESTOR AW ACID WASTE GRV GRAVITY ROOF VENTILATOR iAi FLOOR DATA OUTLET �rY DEMOLISHED FAN POWERED BOX GUH GAS -FIRED UNIT HEATER SOLENOID VALVE - - AV - - ACID VENT � CEILING DATA OUTLET HC HEATING COIL '�i— ANGLE VALVE GW•— GREASE WASTE RELOCATED FAN POWERED BOX HP HEAT PUMP, AIR SOURCE GAUGE COCK TP TRAP PRIMER SUPPLY O TELL/DATA OUTLET AIR VENT l FLOOR TELE/DATA OUTLET HUM HUMIDIFIER NEW VAV HX HEAT EXCHANGER PRESSURE GAUGE Io CEILING TELE/DATA OUTLET EXISTING VAV I yl STRAINER IRH INFRARED HEATER ® JUNCTION BOX — SIZE IN ACCORDANCE rr-1, DEMOLISHED VAV '1F THERMOMETER WELL EQUIPMENT DESIGNATIONS WITH NEC FOR SPECIFIC APPLICATION KEF KITCHEN EXHAUST FAN 19 RELOCATED VAV KSF KITCHEN SUPPLY FAN -'VV\/— EXPANSION JOINT 1011 FLOOR JUNCTION BOX NEW DUCTWORK MAU MAKE-UP AIR UNIT ---il�— UNION AC AIR COMPRESSOR M CEILING JUNCTION BOX EXISTING DUCTWORK MD MOTORIZED DAMPER t- HOSE BIBB OR HYDRANT CID CIRCULATION PUMP Z-' COMBINATION MOTOR STARTER &FUSED DISCONNECT ---------- DEMOLISHED DUCTWORK RTU ROOF TOP UNIT THERMOMETER ET EXPANSION TANK NON -FUSED DISCONNECT SWITCH ® SUPPLY OR OUTSIDE AIR DUCT SA SOUND ATTENUATOR 30 P- EWC ELECTRIC WATER COOLER 'WP' INDICATES WEATHER PROOF, MOTOR RATED RETURN OR EXHAUST AIR DUCT SD SMOKE DAMPER :0 FLOOR DRAIN/FLOOR SINK WITH P-TRAP FD FLOOR DRAIN � FUSED DISCONNECT SWITCH SF SUPPLY FAN CO HUB DRAIN WITH P--TRAP FP FIRE PUMP (EX. 30/15/3 = 30A RATED DISC., 15A FUSES, DUCT TURNING UP VAV VARIABLE VOLUME TERMINAL - COOL ONLY Co/ —� GCO' FLOOR CLEANOUT OFF GRADE CLEANOUT FS FLOOR SINK (EY. INDICATE) SWEATHER PROOF, MOTOR RATED 2—� DUCT TURNING DOWN VFD VARIABLE FREQUENCY DRIVE y CLEANOUT OR WALL CLEANOUT HB HOSE BIBS CIRCUIT BREAKER IN NEMA ENCLOSURE 1 24x 12 CLEAR INSIDE DUCT DIMENSION, FIRST VALUE IS DUCT WIDTH VRF VARIABLE REFRIGERANT FLOW -04�►�D4- DOUBLE CHECK BACKFLOW PREVENTER HD HUB DRAIN MOTOR VSD VARIABLE SPEED DRIVEREDUCED -' PRESSURE PRINCIPLE BACKFLOW JP JOCKEY PUMP ?---► DUCT TRANSITION PREVENTER L LAVATORY —" CIRCUIT HOME RUN �' WT VARIABLE VOLUME & TEMPERATURE CONNECT TO EXISTING t DUCT TAP WITH MANUAL VOLUME DAMPER WH WALL HEATER MS MOP SINK IITT CROSS MARKS INDICATE WIRES (NEUTRAL, HOT, COMMON GROUND, ISOLATED GROUND) NEW SUPPLY AIR GRILLE WSHP HEAT PUMP, WATER SOURCE NFWH NON FREEZE WALL HYDRANT NEW RETURN AIR GRILLE PRV PRESSURE REDUCING VALVE PANELBOARD (240 VOLT AND BELOW) ® NEW EXHAUST AIR GRILLE RPBP REDUCED PRESSURE BACKFLOW PREVENTER PANELBOARD (480 VOLT) FIRE PROTECTION SYMBOLS RV RELIEF VALVE ® TRANSFORMER ® EXISTING SUPPLY AIR GRILLE z EXISTING RETURN AIR GRILL S SINK �' EMERGENCY POWER OFF (EPO) BUTTON ® EXISTING EXHAUST AIR GRILLE MECHANICAL SYMBOLS --�— FIRE DEPARTMENT V N VALVE WITH CABINET SA SHOCK ARRESTOR IT COPPER GROUND BAR ASSEMBLY - FS Y 7 FLOW SWITCH SE SEWAGE EJECTOR N. y DEMOLISHED SUPPLY AIR GRILLE SH SHOWER FM] KWH METER J DEMOLISHED RETURN AIR GRILLE ""�', MANUAL VOLUME DAMPER (VD) IL ALARM VALVE SP SUMP PUMP DEMOLISHED EXHAUST AIR GRILLE FD — - —� FIRE DAMPER (FD) Q DRY PIPE VALVE TD TRENCH DRAIN LIGHT FIXTURE LABELING --► SIDEWALL OUTLET SD SIAMESE CONNECTION TM THERMOSTATIC MIXING VALVE SIDEWALL INLET — - —� FSD SMOKE DAMPER (SD) --fy EXPOSED TYPE SIAMESE CONNECTION TP TRAP PRIMER — - —� FIRE/SMOKE COMBINATION DAMPER (FSD) INSPECTORS TEST CONNECTION U URINAL A 1 UPPERCASE LETTER - FIXTURE TYPE, Q THERMOSTAT/SENSOR REFER TO FIXTURE SCHEDULETES HUMIDISTAT ---© AUTOMATIC DAMPER, OPPOSED BLADE MOTOR GONG WC WATER CLOSET f NL LOWERCASE LETTER -INDICATED SWITCHING GROUP AUTOMATIC DAMPER, PARALLEL BLADE O.S.&Y. VALVE WCB WASHER CONNECTION BOX NUMBER INDICATES CIRCUIT Q DUCT SMOKE DETECTOR B D D BACK DRAFT DAMPER MT TAMPER SWITCH WH WATER HEATER NL -INDICATES NIGHT LIGHT --D4--� FLOOR CONTROL VALVE A 12 \ �,i FIXTURE WITH BI-LEVEL SWITCHING. LOWER CASE ---D�-1 FIRE HOSE VALVE 11 � LETERS INDICATE SWITCH LEGS MECHANICAL/PLUMBING ABBREVIATIONS LIGHT SWITCH SYMBOLS $ SINGLE POLE SWITCH AFF ABOVE FINISH FLOOR CLG CEILING GW GREASE WASTE RV RELIEF VALVE $3 THREE WAY SWITCH AFG ABOVE FINISHED GRADE CO CLEANOUT HW HOT WATER SD STORM DRAIN $4 FOUR WAY SWITCH A/C ABOVE CEILING DCO DOUBLE CLEANOUT HWR HOT WATER RETURN SS SANITARY SEWER DIMMER SWITCH BAS BUILDING AUTOMATION SYSTEM - SEE EMCS DS DOWNSPOUT MTD MOUNTED SV SANITARY VENT B/F BELOW FLOOR EMCS ENERGY MANAGEMENT & CONTROL SYSTEM OD OVERFLOW DRAIN UNO UNLESS NOTED OTHERWISE $wP WEATHERPROOF SWITCH BFF BELOW FINISHED FLOOR FCO FLOOR CLEANOUT ODN OVERFLOW DOWNSPOUT NOZZLE VTR VENT THRU ROOF $M MANUAL MOTOR CONTROLLER, MOTOR RATED B/G BELOW GRADE FLR FLOOR PRV PRESSURE REDUCINQ VALVE WCO WALL CLEANOUT $OS OCCUPANCY SENSOR SWITCH GCO GRADE CLEANOUT RD ROOF DRAIN ® WALL MOUNTED OCCUPANCY SENSOR BRF BELOW RAISED FLOOR ® CEILING MOUNTED OCCUPANCY SENSOR ;r PHOTOCELL AC ALTERNATING CURRENT A AMPS AFF ABOVE FINISHED FLOOR ATS AUTOMATIC TRANSFER SWITCH C CONDUIT CCTV CLOSED CIRCUIT T.V. CLG CEILING DP DISTRIBUTION PANEL EG EQUIPMENT GROUND EEC ELECTRIC EMERG EMERGENCY FA FIRE ALARM FAAP FIRE ALARM ANUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL FLR FLOOR G,GRD GROUND GEN GENERATOR GFI GROUND FAULT CIRCUIT INTERRUPTER HP HORSE POWER HV HIGH VOLTAGE IG ISOLATED GROUND JB JUNCTION BOX LTS LIGHTS LTG LIGHTING LV LOW VOLTAGE MCB MAIN CIRCUIT BREAKER MDP MAIN DISTRIBUTION PANEL MLO MAIN LUGS ONLY MTD MOUNTED HTG HT MOUNTING HEIGHT P POE PH PHASE PB PULL BOX PNL PANEL REC,RECEP RECEPTACLE SS SAFETY SWITCH TEL TELEPHONE TV TELEVISION UNO UNLESS NOTED OTHERWISE V VOLTAGE WP WEATHER PROOF WT WATER TIGHT XFMR TRANSFORMER 0 PHASE LIFE SAFETY SYMBOLS UNSWITCHED EMERGENCY FIXTURE WITH BATTERY BACKUP ® 1e� EXIT SIGN WITH BATTERY BACKUP O FLUSH MOUNTED CEILING SPEAKER ASSEMBLY WITH BACK BOX, TRANSFORMER, AND CEILING BAFFLE (WHITE) [F] FIRE ALARM STROBE - VISUAL ONLY COORDINATE FINISH WITH ARCHITECT QF a FIRE ALARM STROBE - COMBINATION AUDIO & VISUAL COORDINATE FINISH WITH ARCHITECT QQ 4 FIRE ALARM HORN - AUDIO ONLY COORDINATE FINISH WITH ARCHITECT FIRE ALARM MANUAL PULL STATION COORDINATE FINISH WITH ARCHITECT s�c FIRE ALARM SMOKE DETECTOR - 120V W/ BATTERY BACK UP. COORDINATE FINISH WITH ARCHITECT X=DD (DUCT DETECTOR), X=SS (SINGLE STATION) X=ER (ELEVATOR RECALL) ® FIRE ALARM HEAT DETECTOR - 120V W/ BATTERY BACK UP COORDINATE FINISH WITH ARCHITECT HATCHED FIXTURE INDICATES UNSWITCHED FIXTURE - ON EMERGENCY CIRCUIT OR BATTERY PACK BATTERY PACKS SHALL BE SELF -TESTING TYPE AND - SHALL BE RATED FOR 90 MINUTES 5400 LBJ Freeway Suite 125 Dallas, Texas 75240 P. 972.770.2222 F. 972.770.2242 www.entosdesign.com 108752 A. r vC",,FhiS„F�.�. G��i►�.0 �aNAt �N•� 6/06/19 CONTRACTOR SHALL COORDINATE MEP DRAWINGS WITH ALL OTHER DISCIPLINES Texas Registered Engineering Firm F-9218 5020 Tennyson Parkway - Plano, TX 75024 Dallas / Fort Worth 214.432.3030 Houston 832.532.2007 C • For Permit 06/06/2019 For Review 06/04/2019 No. Issued Date Project Novus Academy Project ID: 19-1064-L001 Location Grapevine III 3400 William D. Tate Ave Grapevine, Texas 76051 Sheet Title Cover Sheet Symbols Sheet Number © 2019 MEP = I e MECHANICAL NOTES: 1. IT IS THE INTENT AND MEANING OF THE CONSTRUCTION DOCUMENTS THAT THE CONTRACTOR SHALL PROVIDE A MECHANICAL INSTALLATION THAT IS COMPLETE AND ALL ITEMS AND APPURTENANCES NECESSARY, REASONABLY INCIDENTAL, OR CUSTOMARILY INCLUDED EVEN THOUGH EACH AND EVERY ITEM IS NOT SPECIFICALLY CALLED OUT OR SHOWN. 2. THE CONTRACTOR SHALL MAKE A CAREFUL EXAMINATION OF THE SITE AND THOROUGHLY FAMILIARIZE HIMSELF WITH THE REQUIREMENTS OF THE CONTRACT. UPON COMMENCEMENT OF CONSTRUCTION FOR THE WORK INCLUDED IN THIS CONTRACT, THE CONTRACTOR SHALL BE DEEMED TO HAVE MADE SUCH A STUDY OR EXAMINATION AND THAT HE IS FAMILIAR WITH AND ACCEPTS ALL CONDITIONS OF THE PREMISES. 3. PROVIDE EQUIPMENT, MATERIALS, LABOR, SUPERVISION AND SERVICES NECESSARY FOR OR INCIDENTAL TO THE INSTALLATION OF A COMPLETE AND OPERATING HVAC OR PLUMBING SYSTEM AS SHOWN OR INDICATED ON THE DRAWINGS AND/OR AS SPECIFIED. CONTRACTOR SHALL TAKE PROPER PRECAUTIONS TO PROTECT ALL EXISTING OPERATIONS AND PROPERTY ADJACENT WITH WHICH WORK COMES IN CONTACT OR OVER WHICH HE MAY TRANSPORT, HOIST OR MOVE MATERIALS, EQUIPMENT, DEBRIS, ETC. AND SHALL REPAIR SATISFACTORILY ALL DAMAGES CAUSED BY HIM DURING CONSTRUCTION. THE CONTRACTOR SHALL REPLACE WITH NEW MATERIALS AND/OR EQUIPMENT FAILING TO GIVE SATISFACTORY SERVICE DURING THE WARRANTY PERIOD. THE CONTRACTOR SHALL COORDINATE AND NOTIFY THE BUILDING OWNER AND OPERATOR FOR APPROVAL AND SCHEDULING OF ANY BUILDING OR EXISTING TENANT SYSTEM INTERRUPTION. 4. MATERIALS AND WORKMANSHIP SHALL COMPLY WITH CONTRACT DOCUMENTS, APPLICABLE CODES AND STANDARDS, AND, IN THE CASE OF DIFFERENCES BETWEEN APPLICABLE CODES AND STANDARDS AND THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL PROMPTLY NOTIFY THE ARCHITECT/ENGINEER AND THE OWNER IN WRITING OF SUCH DIFFERENCES. SHOULD THE CONTRACTOR PERFORM ANY WORK THAT DOES NOT COMPLY WITH REQUIREMENTS OF APPLICABLE CODES AND STANDARDS, HE SHALL BEAR ALL COSTS ARISING IN CORRECTING SUCH DEFECTS. APPLICABLE CODES AND STANDARDS SHALL INCLUDE ALL ORDINANCES, UTILITY COMPANY REGULATIONS AND APPLICABLE REQUIREMENTS OF NATIONALLY ACCEPTED CODES AND STANDARDS. 5. THE DRAWINGS WERE PREPARED FROM THE BEST INFORMATION AVAILABLE, BUT DO NOT ATTEMPT TO INDICATE THE LOCATION OF ALL EXISTING EQUIPMENT. THE CONTRACTOR SHALL CAREFULLY INVESTIGATE THE CONDITIONS SURROUNDING THE INSTALLATION OF HIS WORK PRIOR TO PROCEEDING WITH THE INSTALLATION. CHANGES REQUIRED TO THE DESIGN SHOWN ON THESE DRAWINGS DUE TO EXISTING CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER/OWNER FOR REVIEW BY WAY OF SHOP DRAWINGS OR SKETCHES DETAILING THE EXISTING CONDITIONS AND THE PROPOSED CHANGE. 6. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED RECOMMENDATIONS FOR SERVICE INTENDED, AS INTERPRETED BY THE ENGINEER. EXPERIENCED CRAFTSMEN SHALL MAKE THE INSTALLATION OF ALL EQUIPMENT IN A NEAT WORKMANSHIP LIKE MANNER. THE CONTRACTOR SHALL FURNISH ALL MATERIALS, TOOLS, COST AND SERVICE NECESSARY TO COMPLETELY INSTALL ALL MECHANICAL WORK. ALL MECHANICAL AND PLUMBING EQUIPMENT SHALL BE AS SCHEDULED OR APPROVED EQUAL. 7. COORDINATE THERMOSTAT LOCATIONS WITH ARCHITECT PRIOR TO INSTALLATION. DO NOT INSTALL THERMOSTAT ABOVE DIMMER SWITCH. 8. PROPERLY SUPPORT ALL EQUIPMENT AND PIPING WITHIN THE BUILDING AND PROVIDE ADEQUATE PROVISIONS FOR SLOPE AND ANCHORAGE. CONTRACTOR SHALL USE HANGERS, RODS AND INSERTS APPROVED BY UNDERWRITERS LABORATORIES FOR THE SERVICE INTENDED, SECURELY SUPPORTED BY STRUCTURAL MEMBERS WHICH IN TURN ARE SUPPORTED DIRECTLY FROM THE BUILDING STRUCTURE. 9. PROVIDE VIBRATION ISOLATION FOR MOTOR DRIVEN MECHANICAL EQUIPMENT. 10. ALL FANS SHALL CARRY THE CERTIFIED RATING SEAL AUTHORIZED BY AMCA. 11. PROVIDE FLEXIBLE DUCTWORK CONNECTIONS AT EQUIPMENT. 12. DUCTWORK SHALL BE CONSTRUCTED ACCORDING TO SMACNA STANDARDS. DUCT AND FIRE DAMPER SIZES SHOWN ARE AIRSTREAM DIMENSIONS. ALL LONGITUDINAL AND TRANSVERSE SEAMS AND DUCT CONNECTIONS SHALL BE SECURELY FASTENED AND SEALED WITH TAPES OR MASTICS MEETING UL 181A OR UL1818, WELDS, OR GASKETS. 13. INSULATE NEW SUPPLY AND RETURN DUCTWORK AND PLENUMS WITH EITHER EXTERNAL INSULATION TYPE IV DUCT WRAP OR INTERNAL DUCT LINER, 1.5 PCF MINIMUM DENSITY. (SIZES SHOWN ARE AIRSTREAM DIMENSIONS.) DUCTWORK AND PLENUMS WITHIN UNCONDITIONED SPACES SHALL HAVE MINIMUM R-6 INSULATION. EXTERIOR DUCTWORK SHALL HAVE MINIMUM R-8 INSULATION. 14. DIFFUSERS, REGISTERS AND GRILLES SHALL BE BUILDING STANDARD UNLESS NOTED OTHERWISE AND SHALL BE PROVIDE WITH FRAMES COMPATIBLE WITH CEILING TYPE. DO NOT SPAN AIR DEVICES OVER PARTITIONS. 15. PROVIDE AN AIR BALANCING DEVICE FOR EACH SUPPLY AIR OUTLET AND ZONE TERMINAL DEVICE. PROVIDE YOUNG REGULATORS WITH BOWDEN CABLE CONTROL FOR ALL DAMPERS ABOVE INACCESSIBLE CEILING. COORDINATE EXACT LOCATION OF ESCUTCHEONS IN CEILING WITH ARCHITECT PRIOR TO INSTALLATION. 16. CONTRACTOR TO VERIFY RETURN AIR PATH AND INCORPORATE RETURN AIR TRANSFER THROUGH WALLS AS NECESSARY. OPENING SIZED FOR A MAXIMUM OF 500 FPM UNLESS NOTED OTHERWISE. 17. COORDINATE ALL WALLS TO DECK WITH EXISTING DUCTWORK AND EXISTING TERMINAL UNITS. 18. BALANCING OF WATER AND AIR SYSTEMS SHALL BE PROVIDED UNDER THIS CONTRACT FOR ALL SYSTEMS WITHIN TENANT BORDERS AND ADJACENT AREAS THAT MAY BE AFFECTED BY BALANCING FOR THIS TENANT. BALANCING CONTRACTOR TO REVIEW DRAWINGS AND NOTIFY THE CONTRACTOR OF APPURTENANCES NEEDED FOR A PROPERLY BALANCED SYSTEM. TEST AND BALANCE CONTRACTOR TO BE T.A.B. CO. 19. PROVIDE NEBB CERTIFIED AIR BALANCE REPORT. 20. COLD AND HOT WATER PIPING SHALL BE TYPE L HARD DRAWN COPPER WITH WROUGHT COPPER FITTINGS. PROVIDE SOFT COPPER PIPING UNDER SLAB TO AVOID UNDERGROUND FITTINGS. 21. INSULATE DOMESTIC HOT WATER AND RECIRCULATION LINES (1" THICK) AND DOMESTIC COLD WATER LINES (1/2" THICK) WITH OWENS CORNING FIBERGLASS 25 ASJ, JOHNS-MANVILLE AP OR APPROVED EQUAL, SEALED TO PREVENT SWEATING AND CONTINUOUS THROUGH WALLS, FLOORS, CEILINGS. ALL HOT WATER PIPING SHALL BE INSULATED PER THE ENERGY CODE. COLD WATER PIPING SHALL BE INSULATED IN EXTERIOR WALLS, CEILINGS OR IN SPACES EXPOSED TO OUTDOOR TEMPERATURES WITH 1" THICK FIBERGLASS INSULATION. 22. SOIL, WASTE AND DRAIN PIPING, 2" AND LARGER, SHALL BE SERVICE WEIGHT CAST IRON. WASTE PIPING BELOW THE SLAB SHALL HAVE BELL AND SPIGOT CAST IRON MANUFACTURED TO ASTM A 74 WITH TY-SEAL GASKETS MANUFACTURED TO ASTM C 564. CAST IRON PIPING ABOVE THE SLAB SHALL BE 'NO -HUB' PIPE AND FITTINGS MANUFACTURED TO CISPI 301. VENT PIPING MAY BE SCHEDULE 40 GALVANIZED STEEL, DWV COPPER OR SERVICE WEIGHT CAST IRON. ALL CAST IRON SOIL PIPE AND FITTINGS SHALL BE MARKED WITH THE COLLECTIVE TRADEMARK OF THE CAST IRON SOIL PIPE INSTITUTE AND BE LISTED WITH NSF INTERNATIONAL. LABORATORY CHEMICAL WASTE SYSTEMS SHALL BE SCHEDULE 40 CPVC MANUFACTURED TO ASTM F 2618. CHARLOTTE PIPE OR APPROVED EQUIVALENT. IF APPROVED BY LOCAL CODES, SOIL, WASTE, AND DRAIN PIPING, 2" AND LARGER, SHALL BE POLYVINYL CHLORIDE (PVC) SCHEDULE 40 PIPING, ASTM AND NSF STAMPED AND APPROVED. FITTINGS SHALL BE PVC SCHEDULE 40 ASTM STAMPED AND APPROVED. 23. HOT WATER CIRCULATING SYSTEMS OR HOT WATER HEAT TRACE SHALL HAVE TIMECLOCK CAPABLE CONTROL 24. PLUMBING FIXTURES AND EQUIPMENT SHALL BE FURNISHED AND INSTALLED COMPLETE WITH TRIM AND ALL OTHER APPURTENANCES REQUIRED TO CONNECT TO ROUGH -IN PIPING AT FLOORS AND WALLS UNLESS OTHERWISE SPECIFIED. 25. WATER HEATING EQUIPMENT WITHOUT INTEGRAL HEAT TRAPS WILL HAVE HEAT TRAPS INSTALLED ON THE SUPPLY AND DISCHARGE PIPING. 26. PVC PIPING LOCATED IN PLENUM RETURN MUST MEET ASTM E84 AND HAVE A FIRE SPREAD OF 25/50. ALL PIPING SHALL MEET ALL LOCAL CODE AND AMENDMENT REQUIREMENTS. 27. EXISTING EQUIPMENT NOTES: A. CONTRACTOR SHALL INSPECT EXISTING PLUMBING AND HVAC EQUIPMENT PRIOR TO SUBMITTING HIS BID. B. CONTRACTOR SHALL INCLUDE IN HIS BID A THOROUGH START-UP SERVICING AND CLEANING OF ALL EXISTING EQUIPMENT. PLACE ALL EXISTING SYSTEMS/EQUIPMENT IN PROPER OPERATING ORDER. C. IF REPAIRS ARE NECESSARY TO PLACE EXISTING EQUIPMENT IN WORKING ORDER, PROVIDE OWNER WITH A DETAILED WRITTEN REPORT OF NECESSARY REPAIRS AND A COST PROPOSAL TO PERFORM THE WORK. ALL SUCH SERVICE REPORTS SHALL BE DELIVERED TO THE OWNER WITHIN TWO DAYS OF NOTICE TO PROCEED. OWNER RESERVES THE RIGHT TO HAVE ANY REQUIRED REPAIRS DONE BY OTHERS AND TO SEEK OTHER OPINIONS OR REQUIRED REPAIRS. 28. PROVIDE INSTALLATION, OPERATION AND MAINTENANCE MANUALS TO THE OWNER. 29. STANDARD NO -HUB COUPLINGS SHALL CONFORM TO CISPI 310 (MOST CURRENT EDITION) AND SHALL BE LISTED BY NSF INTERNATIONAL 30. HEAVY DUTY COUPLINGS SHALL CONFORM TO THE REQUIREMENTS OF ASTM 1540 AND FM 1680 CLASS I. 31. COMPRESSION GASKETS FOR HUB & SPIGOT SHALL CONFORM TO THE REQUIREMENTS OF ASTM STANDARD C 564 AND ASTM C 1563 (MOST CURRENT EDITION) 32. JOINTS FOR PIPE AND FITTINGS SHALL CONFORM TO THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND LOCAL CODE REQUIREMENTS. GENERAL NOTES ELECTRICAL NOTES: 1. FOR EXACT LIGHT FIXTURE LOCATIONS, LIGHT FIXTURE SPECIFICATIONS, EXACT RECEPTACLE LOCATIONS AND MOUNTING HEIGHTS, REFER TO ARCHITECTURAL PLANS AND DETAILS. MEP PLANS ARE FOR CIRCUITING INFORMATION AND LIFE SAFETY ONLY. 2. COORDINATE SWITCH/DIMMER LOCATIONS AND SWITCHING/DIMMING PATTERNS WITH ARCHITECT PRIOR TO INSTALLATION. 3. POKE-THROUGH/FLOOR BOX SPECIFICATIONS SHALL BE AS FOLLOWS: DUPLEX - WALKER RC3 (OR EQUIVALENT) QUADRAPLEX - WALKER RC4 (OR EQUIVALENT) FURNITURE FEED (TWO DEVICES SHOWN) - WALKER RC7FFTC FOR POWER, WALKER RC900AM-114 FOR TELE/DATA (OR EQUIVALENTS) FURNITURE FEED (ONE DEVICE SHOWN) - WALKER RC9FFTC COMBINATION POWER/TELE/DATA TOMBSTONE (OR EQUIVALENT) SLAB ON GRADE FLOOR BOX - WALKER OMNIBOX 880CS3-1 (OR EQUIVALENT) 4. TENANT'S CABLING VENDOR TO VERIFY THAT TELE/DATA POKE -THROUGH QUANTITIES SHOWN ON PLANS ARE SUFFICIENT FOR CABLING REQUIREMENTS. CONTACT AOS/ARCHITECT IF ADDITIONAL DEVICES ARE REQUIRED. 5. PROVIDE OUTLET BOXES FOR ALL RECEPTACLES, SWITCHES, TELE/DATA DEVICES, ETC. AS REQUIRED PER PLANS. 6. ALL WET LOCATION RECEPTACLES (WITHIN 6' OF WET LOCATION) SHALL BE RATED 'GFI'. ALL OUTDOOR RECEPTACLES SHALL BE RATED 'WP' AND 'GFI'. ALL VENDING MACHINE RECEPTACLES TO BE GFI PROTECTED. 7. ALL RECEPTACLES SHALL BE GROUNDED. ALL DEVICES TO MATCH BUILDING STANDARD TYPE, U.N.O. ON PLANS. ALL FINISHES SHALL BE SELECTED BY ARCHITECT. 8. COORDINATE WITH BUILDING MANAGEMENT AND STRUCTURAL ENGINEER PRIOR TO INSTALLING ANY PENETRATIONS THROUGH SLABS, FIRE RATED WALLS, AND ROOFS TO VERIFY ANY X-RAY OR OTHER REQUIREMENTS NECESSARY PRIOR TO PERFORMING WORK. FINISHED INSTALLATION SHALL MAINTAIN FIRE PROOF, WATER PROOF, AND STRUCTURAL INTEGRITY OF SYSTEM PENETRATED. 9. ALL 120V AND 277V BRANCH CIRCUITS ARE PROTECTED BY 1P/20A BREAKERS U.N.O. ON PLANS. 10. AT ALL LOCATIONS WHERE MULTIPLE SWITCHES ARE LOCATED TOGETHER, CONTRACTOR SHALL GANG SWITCHES UNDER ONE COVER PLATE. 11. ALL NEW LIGHT FIXTURES TO BE PROVIDED WITH LAMPS INCLUDED. ALL NEW/RELOCATED LIGHT FIXTURES SHALL BE SUPPORTED FROM ABOVE STRUCTURE, SEPARATE FROM CEILING GRID. PROVIDE AND INSTALL ALL REQUIRED ACCESSORIES RECOMMENDED BY MANUFACTURER FOR A COMPLETE INSTALLATION. CLEAN AND RELAMP ALL EXISTING TO REMAIN FIXTURES AS REQUIRED, VERIFY EXACT SCOPE IN FIELD. 12. ALL CONDUCTORS ARE TO BE COPPER, #12 GAUGE MINIMUM. CIRCUITS OF 120V EXCEEDING 115 FEET AND CIRCUITS OF 277V EXCEEDING 270 FEET SHALL BE #10 GAUGE MINIMUM. CONTROL WIRING SHALL BE #14 GAUGE MINIMUM. ALL CONNECTIONS SHALL BE MADE WITH U.L. LISTED CONNECTORS. UPSIZE ALL SHARED NEUTRALS TO #10 WIRE. 13. DEMOLISH ALL UNUSED CONDUIT AND WIRING BACK TO SOURCE. 14. UTILIZE EXISTING BASE BUILDING EMERGENCY LIGHTING CIRCUITS FOR ALL EMERGENCY FIXTURES AND EXIT SIGNS. VERIFY MAXIMUM OF 16A PER CIRCUIT AFTER ADDITION OF NEW FIXTURES. IN THE ABSENCE OF EMERGENCY CIRCUITS, PROVIDE AND INSTALL BATTERY PACKS IN ALL EMERGENCY FIXTURES AND EXIT SIGNS. 15. IF ENERGY MANAGEMENT SYSTEM (EMS) IS PRESENT IN BUILDING, CONTRACTOR TO ROUTE ALL LIGHTING CIRCUITS THROUGH EMS AS DIRECTED BY BUILDING ENGINEER. COORDINATE IN FIELD. 16. PROVIDE POWER TO ALL NEW HVAC, VAV BOXES, DAMPERS, ETC. FROM NEAREST 120V GENERAL PURPOSE CIRCUIT OR FROM BUILDING HVAC CONTROL PANEL AS REQUIRED. MATCH BUILDING STANDARD. COORDINATE ANY CONNECTIONS TO CONTROL SYSTEM WITH BUILDING ENGINEER. VERIFY LOCATIONS AND QUANTITIES WITH MECHANICAL PLANS. PROVIDE LOCAL DISCONNECT SWITCH AT EQUIPMENT. 17. STEEL EMT CONDUIT SHALL BE UTILIZED FOR ALL HOME RUNS, 3/4" U.N.O. ON PLANS. MC CABLE SHALL BE ALLOWED FOR BRANCH WIRING BETWEEN LIGHTS AND RECEPTACLES U.N.O. 18. FOR EACH SINGLE PHASE OR THREE PHASE MOTOR, CONTRACTOR TO INSTALL LOCAL DISCONNECT. REFERENCE PLANS FOR DISCONNECT TYPE. 19. ALL FEEDERS AND BRANCH WIRING (120-480V), CONTROL WIRING, AND COMMUNICATION WIRING (LOW VOLTAGE) SHALL BE COMPLETELY ENCLOSED IN ELECTRICAL RACEWAY FROM SOURCE TO TERMINATION. INSTALL NYLON PULL CORD IN ALL RACEWAYS. ALL RACEWAYS SHALL BE FULLY SUPPORTED FROM SOURCE TO TERMINATION. PROVIDE AND INSTALL ALL SUPPORTING MEANS AS REQUIRED FOR A COMPLETE SYSTEM. CONTRACTOR TO INSTALL PULL BOXES, JUNCTION BOXES, WIREWAYS, ETC. WHERE REQUIRED PER NEC FOR A COMPLETE, CODE COMPLIANT SYSTEM. 20. CONTRACTOR TO REFERENCE MECHANICAL AND PLUMBING DRAWINGS FOR EXACT LOCATIONS AND QUANTITIES OF ALL HVAC/PLUMBING EQUIPMENT PRIOR TO SUBMITTING BID AND ROUTING CIRCUITRY. CONTACT AOS IMMEDIATELY IF MECHANICAL/PLUMBING PLANS SHOW EQUIPMENT THAT IS NOT CIRCUITED ON ELECTRICAL PLANS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE POWER TO ALL NEW HVAC/PLUMBING EQUIPMENT, TO ENSURE A COMPLETE, WORKABLE SYSTEM. 21. CONTRACTOR TO OEITAIN APPROVAL FROM BUILDING MANAGEMENT FOR ANY SHUTDOWNS REQUIRED.' UNDER NO CIRCUMSTANCES SHALL ANY ELECTRICAL DISTRIBUTION EQUIPMENT BE SHUT DOWN WITHOUT THE EXPRESS PERMISSION OF BUILDING MANAGEMENT. 22. CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR ANY DAMAGE TO PROPERTY (OR ADJACENT PROPERTY) CAUSED BY HIM DURING CONSTRUCTION AND FOR THE REPLACEMENT/REPAIR THEREOF. 23. CONTRACTOR SHALL HONOR ALL GUARANTEE COMMITMENTS FOR THE DESIGNATED TIME FRAME. REPLACE/REPAIR ANY FAILING EQUIPMENT/SYSTEMS AS DIRECTED BY BUILDING MANAGEMENT DURING THIS TIME FRAME. 24. ALL NEW EQUIPMENT TO BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. CONTRACTOR TO PROVIDE AND INSTALL ALL APPURTENANCES NECESSARY FOR A COMPLETE INSTALLATION. 25. ALL WORK SHALL FULLY COMPLY WITH ALL APPLICABLE CODES. CONTACT AOS ;AND/OR LOCAL CODE OFFICIALS TO RESOLVE ANY QUESTIONS REGARDING CODE ISSUES PRIOR TO PERFORMING WORK. SHOULD CONTRACTOR PROCEED WITH WORK IN QUESTION WITHOUT COORDINATING WITH CODE OFFICIALS, CONTRACTOR SHALL BEAR ALL COSTS ASSOCIATED WITH RE -WORK DUE TO CODE VIOLATIONS. 26. PRIOR TO SUBMITTING BID, CONTRACTOR TO VISIT SITE TO FAMILIARIZE HIM/HER SELF WITH ALL EXISTING FIELD CONDITIONS. NOTIFY ARCHITECT/AOS OF ANY ITEMS DISCOVERED THAT ARE NOT COVERED ON PLANS THAT WILL AFFECT PRICING. 27. ALL NEW TRANSFORMERS SHALL U.L. LISTED DRY TYPE. SEE PLANS FOR RATINGS. ALL FLOOR EQUIPMENT SHALL BE MOUNTED ON 4" HOUSEKEEPING PAD. 28. REFERENCE PLANS FOR ALL NEW EQUIPMENT LOCATIONS. MANUFACTURER OF ALL NEW DISTRIBUTION EQUIPMENT SHALL MATCH BUILDING STANDARD. VERIFY MANUFACTURER DURING SITE VISIT. ALL NEW PANELBOARDS TO HAVE COPPER BUS. 29. FINISHED WORK TO FULLY COMPLY WITH ALL BASE BUILDING STANDARDS. OBTAIN MANUAL OF BUILDING STANDARDS FROM BUILDING MANAGEMENT PRIOR TO SUBMITTING BID AND BEGINNING WORK. 30. LOCAL DISCONNECTS ARE PROVIDED WITH ALL CRAC (COMPUTER ROOM AIR CONDITIONING) EQUIPMENT U.N.O. 31. ALL SURFACE MOUNTED RACEWAY SHALL BE ALUMINUM WITH DIVIDER. RACEWAYS SHALL BE SIZED PER NEC FOR WIRE QUANTITY THROUGH RACEWAY. FINISH OF RACEWAY TO BE SELECTED BY ARCHITECT. 32. CONTRACTOR TO INSTALL NEW KWH METERS FOR ANY NEW CRAC EQUIPMENT, OR FOR ANY NEW SUPPLEMENTAL HVAC SPLIT SYSTEMS OR ROOF TOP UNITS. REFERENCE PLANS FOR MORE DETAILED METERING INSTRUCTIONS. 33. UPDATE ALL AFFECTED PANEL SCHEDULES UPON COMPLETION OF WORK. UPDATED SCHEDULES MUST BE TYPED. 34. ALL ELECTRIC ROOM INSTALLATIONS SHALL BE DONE IN SUCH A WAY AS TO MAXIMIZE WALL/FLOOR SPACE FOR FUTURE EQUIPMENT. 35. THE FIRE ALARM CONTRACTOR IS RESPONSIBLE FOR SUBMITTING FIRE ALARM CONSTRUCTION DOCUMENTS TO LOCAL OFFICIALS FOR PERMIT. FIRE ALARM CONTRACTOR IS RESPONSIBLE FOR DETERMINING EXACT QUANTITIES AND LOCATIONS OF ALL FIRE ALARM DEVICES TO MEET ALL APPLICABLE CODES AND FOR DETERMINING REQUIREMENTS FOR CONNECTIONS TO EXISTING BUILDING FIRE ALARM SYSTEM TO ENSURE A COMPLETE, WORKABLE SYSTEM. INSTALL NEW FIRE ALARM SYSTEM IN BUILDING WHERE DIRECTED BY LOCAL CODE OFFICIALS. 36. CONTRACTOR SHALL, PROVIDE ALL ITEMS AND ACCESSORIES AS REQUIRED PER .ALL RELATED MANUFACTURER'S RECOMMENDATIONS TO PROVIDE A COMPLETE, WORKABLE ELECTRICAL SYSTEM PER THE INTENT OF THE CONTRACT DOCUMENTS, EVEN THOUGH ALL NECESSARY ITEMS AND ACCESSORIES ARE NOT SHOWN ON PLANS. 37. CONTRACTOR TO INSTALL A GROUNDING SYSTEM THAT FULLY COMPLIES WITH THE NEC AND ANY LOCAL CODES. 38. CONTRACTOR TO INSTALL CONDUIT WITH PULL STRING FROM BUILDING TELEPHONE CLOSET TO TENANT'S PHONE BOARD. COORDINATE EXACT CONDUIT SIZE AND CONDUIT ROUTING :IN FIELD WITH TENANT AND BUILDING ENGINEER. 39. CONTRACTOR TO ROUTE 1-#6 INSULATED GROUND WIRE FROM BUILDING GROUND RISER TO TENANT TELEPHONE BOARD. IF TENANT HAS COPPER GROUND BAR IN SERVER/IT ROOM, CONTRACTOR MAY UTILIZE IT TO SERVE #6 GROUND WIRE TO PHONE BOARD. COORDINATE EXACT GROUNDING REQUIREMENTS IN FIELD WITH TELEPHONE SYSTEM INSTALLER PRIOR TO INSTALLING GROUND WIRE. 40. IN KITCHEN AREAS, ALL SINGLE-PHASE RECEPTACLES RATED 150V TO GROUND OR LESS, 50A OR LESS AND ALL THREE-PHASE RECEPTACLES RATED 150V TO GROUND OR LESS, 100A OR LESS TO BE GFCI PROTECTED PER NEC 210.8. ALL NOTES MAY NOT APPLY. DEMOLITION NOTES: 1. PROTECT THE EXISTING EQUIPMENT AND SYSTEMS TO REMAIN OPERATIONAL. IF DAMAGED OR DISTURBED IN THE COURSE OF THE DEMOLITION WORK, IT IS THE CONTRACTOR'S RESPONSIBILITY TO REPAIR OR REPLACE WITH NEW PRODUCT OF EQUAL CAPACITY, QUALITY AND FUNCTIONALITY. 2. CONTRACTOR SHALL COORDINATE WITH THE OWNER TO ARRANGE THE SHUT OFF OF UTILITIES. 3. CONTRACTOR SHALL BOX AND/OR PALLETIZE ALL DEMOLISHED EQUIPMENT AND PROTECT IT ON SITE. REMOVE THESE ITEMS FROM THE SITE AT THE DIRECTION OF THE OWNER. 4. CONTRACTOR SHALL NOT CONSIDER DEMOLITION AND ALTERATION NOTES TO BE ALL-INCLUSIVE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSPECT AND ASSESS EACH AREA TO FULFILL THE INTENT OF THE COMPLETE DESIGN. REFER TO ARCHITECTURAL DOCUMENTS FOR DEFINITION OF SCOPE FOR DEMOLITION AREAS AND ADDITIONAL REQUIREMENTS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VISIT THE SITE TO CONFIRM THE EXTENT OF DEMOLITION AND RESOLVE ANY DISCREPANCIES WITH OWNER'S/LANDLORD'S CONSTRUCTION MANAGER. 5. FOR DEMOLITION AREAS, THE CONTRACTOR SHALL REVIEW THE ARCHITECTURAL, MECHANICAL, PLUMBING, ELECTRICAL AND FIRE SUPPRESSION DEMOLITION DRAWINGS AND REMOVE WIRING, RACEWAYS, AND ELECTRICAL EQUIPMENT ASSOCIATED WITH THE MECHANICAL, PLUMBING AND FIRE SUPPRESSION DEMOLITION. 6. ENSURE THAT ALL LIFE SAFETY SYSTEMS REMAIN OPERATIONAL AND MEET LIFE SAFETY CODE REQUIREMENTS FOR ALL OCCUPIED AREAS THAT REMAIN OPERATIONAL DURING/AFTER DEMOLITION. THIS INCLUDES, BUT IS NOT LIMITED TO, EGRESS PATHWAYS, FIRE ALARM SYSTEMS, EGRESS LIGHTING AND OTHER LIFE SAFETY SYSTEMS. 7. PROTECT EXISTING EQUIPMENT AND SYSTEMS INTENDED TO REMAIN OPERATIONAL. IF DAMAGED OR DISTURBED IN THE COURSE OF THE DEMOLITION WORK, IT IS THE CONTRACTOR'S RESPONSIBILITY TO REPAIR OR REPLACE WITH NEW PRODUCT OF EQUAL CAPACITY, QUALITY AND FUNCTIONALITY. 8. RE-ROUTE AND RE -CONNECT ANY CIRCUITS) THAT ARE TO REMAIN IN USE BUT INTERFERES WITH THE NEW CONSTRUCTION. 9. WORK REQUIRING INTERRUPTION OF ELECTRICAL POWER, WHICH WOULD ADVERSELY AFFECT THE NORMAL OPERATION OF THE OWNER/LANDLORD'S PROPERTY OR OTHER BUILDING TENANTS, SHALL BE DONE AT A TIME OTHER THAN NORMAL WORKING HOURS. SCHEDULE ALL OUTAGES WITH OWNER/LANDLORD PRIOR TO SHUTDOWN. 10. OWNER/LANDLORD RESERVES THE RIGHTS TO ALL DEMOLISHED MATERIALS. COORDINATE AND VERIFY EQUIPMENT INTENDED TO BE SALVAGED PRIOR TO DEMOLITION. MATERIALS THAT OWNER/LANDLORD REQUESTS TO BE RE -USED OR SALVAGED, THE MATERIALS SHALL BE REMOVED IN A NEAT WORKMAN LIKE METHOD TO ALLOW THEIR RE -USE. PROTECT THE SALVAGE MATERIALS FOR REUSE BY PROPERLY PACKAGING THE MATERIALS TO PROTECT SALVAGED MATERIALS FROM DAMAGE; SECURELY PACKAGE ALL SALVAGE MATERIAL'S INSTALLATION HARDWARE AND PARTS TO SALVAGED MATERIALS. 11. REMOVE UNUSED BRANCH CIRCUITS BACK TO BRANCH PANELBOARD OF ORIGIN, MARK BREAKER AS 'SPARE' AND MAKE ELECTRICALLY SAFE. REMOVE ALL ABANDONED CONDUITS ABOVE LAY -IN CEILING, EXPOSED CONDUITS, FLEXIBLE CONDUITS, SURFACE RACEWAY, SURFACE MOUNTED OUTLET/JUNCTION BOXES, AND EQUIPMENT UNLESS NOTED OTHERWISE. 12. REMOVE DEMOLISHED MATERIAL. FROM PROJECT SITE IN ACCORDANCE WITH ALL APPLICABLE CODES, STANDARDS AND REGULATIONS. FOLLOW ALL STATE AND LOCAL REGULATIONS AND CODES FOR PROPER DISPOSAL. FIRE PROTECTION NOTES: 1. THIS IS A MODIFICATION TO A HYDRAULICALLY CALCULATED, PREVIOUSLY APPROVED SYSTEM. RELOCATE OR ADD HEADS AS REQUIRED BY NEW WALL LAYOUT. 2. EXISTING FIRE PROTECTION PIPING IS NOT SHOWN. BASED ON NEW SPRINKLER HEAD LOCATION, ACTUAL NEW PIPE ROUTING AND CONNECTION TO EXISTING PIPING SHALL BE DETERMINED BY THE FIRE PROTECTION CONTRACTOR AFTER LOCATING EXISTING PIPING DURING FIELD VERIFICATION WORK. 3. NOTIFY AND COORDINATE WITH ADMINISTRATION PRIOR TO SHUTDOWN OF ANY FIRE PROTECTION UTILITY. SHUTDOWN TIME TO BE MINIMAL. NOTIFICATION SHALL BE IN WRITING 24 HOURS PRIOR TO SHUTDOWN. 4. USE ARCHITECTURAL REFLECTED CEILING PLAN TO LOCATE ALL OF THE NEW SPRINKLER HEADS. SUBMIT TO ARCHITECT FOR APPROVAL. 5. COORDINATE NEW WORK WITH ALL OTHER TRADES. 6. FINAL PIPING LAYOUT AND SIZE SHALL BE DETERMINED BY FIRE PROTECTION CONTRACTOR. 7. THE ENTIRE SPACE SHALL BE 100% SPRINKLED WITH FINAL DEVELOPMENT. 8. SPRINKLER HEADS TO BE QUICK RESPONSE HEADS AND/OR MATCH BUILDING STANDARDS. 17 t 0 _-f,42�, 5400 LBJ Freeway Suite 125 Dallas, Texas 75240 P . 972.770.2222 F. 972.770.2242 www.enfosdesign.com ROSS MCFARLAND ,..,.......... ............ ..I-. a� 108752 •_ I, 0,,N,4!c w�;;' CONTRACTOR SHALL COORDINATE MEP DRAWINGS WITH ALL OTHER DISCIPLINES Texas Registered Engineering Firm F-9218 5020 Tennyson Parkway - Plano, TX 75024 Dallas / Fort Worth 214.432.3030 Houston 832.532.2007 rn 0 0 CD N m 0 C For Permit 06/06/2019 For Review 06/04/2019 No. Issued Date Project Novus Academy Project ID: 19-1064-L001 Location Grapevine III 3400 William D. Tate Ave Grapevine, Texas 76051 Sheet Title Cover Sheet Notes Sheet Number 02019 MEPM 2 :1 .. .+ I. .. .I— P .. y r ,. L-- y . - I . .. L—J, i r uJ .. L L� �J e ---------------------� F-'i Fy L_`\-,I L_ I F-�I F-�I F'-�I am1-----------� I L \� I i i I I J---------------------------- I \I I \I Fy '1 Fy 'I I I I , k_J I ,T \ C) ( 1 Iry �I c) C i �V I i 0 -------- -- --------- - 1------------------------- -. r4 �I � 71 E Nor I C Fyn------------------ 1--------------- I1 T; 512 r. I / 1 LJ ---- _Ic_J _ I �-------- --1 2 I + 1-7 _ - F�/� I� ® c------------------------ w 1 I Y J L J 1 (I C- JE -----------------------`- F IL I' �\ rh / _ _---- - - - - - - - - - - - - - - - - - - .c I I I 1 i-------------- F I\\i ' I I �t�7 - F�+,� r\--1 \N �- —I T CONFERENCE N.I.C. 0 r r W rEA NORTH 40 1 DEMOLITION PLAN - MECHANICAL SCIM i/f of -or LOBBY N.I.C. L/A GENERAL NOTES: A. FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID AND CONSTRUCTION. REPORT ANY DEFICIENCIES TO AOS ENGINEERING. B. REUSE AND RELOCATE ALL GRILLES WHERE APPLICABLE. CLEAN ALL EXISTING AND RELOCATED GRILLES TO "LIKE NEW CONDITION. KEY NOTES: ❑1 EXISTING EXHAUST SYSTEM AN ALL ASSOCIATED DUCTWORK TO BE REMOVED AND RETURNED TO BUILDING STOCK. CAP ALL UTILITIES AT MAIN. [2 EXISTING ROOF TOP UNIT TO BE REMOVED AND RETURNED TO BUILDING STOCK. CAP ALL UTILITIES AT MAIN. SEAL ALL ROOF PENETRATIONS WEATHER TIGHT AND MAINTAIN ALL ROOF WARRANTIES. • 5400 LBJ Freeway Suite 125 Dallas, Texas 75240 P. 972.770.2222 F. 972.770.2242 www.entosdesign.com 108752 CONTRACTOR SHALL COORDINATE MEP DRAWINGS WITH ALL OTHER DISCIPLINES z Texas Registered Engineering Firm F-9218 �* 5020 Tennyson Parkway - Plano, TX 75024 0 Dallas / Fort Worth 214.432.3030 cn Houston 832.532.2007 Q For Permit 06/06/2019 For Review 06/04/2019 No. Issued Date Project Novus Academy Project ID: 19-1064-L001 Location Grapevine III 3400 William D. Tate Ave Grapevine, Texas 76051 1 Sheet Title Demolition Floor Plan Sheet Number 02019 i. �J. FY 160 160 400 315 310 190 190 CLASSROOM 9 f ® 190 CLASSROOM 10 CLASSROOM 8 CLASSROOM 7 - G G LET- 520 ® T275 BREAKROOM 225 310 `� r �1140 11;=1 TR R1 S1 155 R1 Iri "625 � 155 190163M ®- 12"o S1 190 190 285 S1 18x1 11 v 81 Ito:].105120� 24 8"� 105 285 ® I I Eroi I Ahm 140© 16x14 115 -1 To S1 � � - • 65 14 10" 145H 16x16 C) CAP 5L�, ,t 60 S1 8"o STOR 2 41 $1 _100 MECHANICAL 14"o � C 100 r- �1 1 O5 00 - Ero 8"0 �J 9 � OFFICE 4 65 S1 d WOMEN ® 105 145� 26x1 � C) (D 300® 14x14 I— �T I CLASSROOM 11 870 250 OFFICE 1 - Z155 MEN ® � 355 � , 0x10 S1 105 S1 S1 145 ® L24 260 130 145 145 Q ED 1 1 105 105 . ® f CONFERENCE 240T STORAGE _ N.I.C. { I COMMONS 1365 T S1 ET] � S1 per—' --10"� L180 O � 80 _ 2260 OFFICE 2 E 130 ( ❑ 1S1 05 /-- 1To .rq- _e (T� F 10 -12"o ELECTRICAL 0 ` 1OS 14"o q 130 18x16 565 JAN. 1 E245 ]hl N I ® 240 CLASSROOM 12 240 � 260 .�`' � I� 270 3 OFFICE 5 80 —® _ 245 171 R 2 1 C"0 F�1 T 480 1to FIRE ALARM ❑ / 270 �� �14x14 S1 � � ( 9--r-1000 � � 1 105 G165 / C 130 2 SERVER RM. j2060 I I R1 J 105 130 260 1 V200 / C 32x 16 /16x1I- E 50 '-16x14 OFFICE 3 I 12x14 100 18x16 Ell 100 I I� 390 640 THERAPY � �,},r COPY R1 S1 � �'�-tOx10 � OFFICE CAP 115 �105 145 STO R TI�J 1 105 105 1 255® 195 S1 11680 S1 1ox10 14"� 12"o 12�j �105 CLA 14x14 65 20x14 / 26x14� 10x10 " coo 12"o TO 12 o-.1 + 1 1 0. J F E/J 14„� e-- 115 75 115 115 115 115 115 �720 © 720 115 560 t� 1 1 1260 1055 720 UT In CLASSROOM b g"o 245 ® E-01 245 �� ' 245 525 245 245 245 CLASSROOM 4 245 CLASSROOM 3 CLASSROOM 5 E CLASSROOM 2 T 245 NORTH 4 1 FLOOR PLAN - MECHANICAL. 0SCALE: VS' : T-Or EXHAU5T FAN 50HEDULE LOBB N.I.0 GENERAL NOTES: A. FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID AND CONSTRUCTION, REPORT ANY DEFICIENCIES TO AOS ENGINEERING. B. REUSE AND RELOCATE ALL GRILLES WHERE APPLICABLE. CLEAN ALL EXISTING AND RELOCATED GRILLES TO "LIKE NEV CONDITION. C. MOUNT ALL NEW AND RELOCATED THERMOSTATS A MINIMUM OF 4T ABOVE FINISHED FLOOR. THERMOSTAT LOCATIONS ARE DIAGRAMMATIC. FIELD VERIFY EXACT PLACNENT OF THERMOSTATS WITH TENANT AND ARCHITECT PRIOR TO CONSTRUCTION. D. FOR ALL HVAC EQUIPMENT, MAINTAIN ALL MANUFACTURER REQUIRED CLtARANCES FOR ACCESS AND MAINTENANCE. E. PROVIDE SMOKE/FIRE DAMPERS FOR ALL NEW PENETRATIONS IN FIRE RATED WALL. FIELD VERIFY THAT EXISTING PENETRATIONS HAVE APPROPRIATE FIRE/SMOKE DAMPERS. KEY NOTES: ❑1 EXISTING EXHAUST SYSTEM AND CFMS TO REMAIN. CONTRACTOR TO VERIFY CAPACITY AND REPORT ANY DEFICIENCIES TO AOS ENGINEERING PRIOR TO BID OR CONSTRUCTION. D PROVIDE AND INSTALL MOTORIZED DAMPER. INTERLOCK MOTORIZED DAMPER WITH ASSOCIATED RTU. DAMPER TO ENGAGE WHEN UNIT GOES INTO HEATING MODE. ❑3 PROVIDE AND INSTALL EXHAUST FAN PER THE EXHAUST FAN SCHEDULE ON THIS SHEET. ROUTE EXHAUST DUCT ABOVE CEILING AS SHOWN ON PLANS AND TERMINATE WITH OPEN END. PROVIDE 1/4"X1/4" STEEL HARDWARE MESH. TWO STEEL CHANNELS SECURED TO STRUCTURE �I HANGER RODS FLEXIBLE CONNECTION CEILING EXHAUST FAN -AP- AIRFLOW STRUCTURE A A CEILING "_' U_U / TRANSITION TO SIZE �220 INDICATED ON PLANS EXHAUST GRILLE FURNISHED BY FAN MANUFACTURER SSROOM 1 AIRFLOW \19220 2 CEILING MOUNTED EXHAUST FAN DETAIL \19220 SCALD NOT TO SCALE f-"t:74 AN k /,I t2- "r4 DL.l oU4, U*t 1607 Z�r� 11.tG 54;4�_ lion 450 VCNXft FAN MOTOR owe. LOCATION SERVES MMk Mom* TYPE MOW Q.86) GPM ESP ON K*J RPM DRIVE VOLTSA'H HP REMARIcS W4 CEILING SERVER 6REE1*60K 5P-050 CABINET ( 10 ISO 026 1050 DIRECT II5A I?bW I-5 NOTES: S, A EQUIPMENT TO BE CLEARLY LABS.®. I. PRE -WIRED DISC MT SWITCH B. ACCEPTABLE MANUFACTURERS ARE: ACME,1WN CITY FANS, COOK 6RAMWGK 2. PRE-WIR® SPEW CONTROLLER C. COORDINATE EXACT LOCATION HN LANDLORD AND STRUCTURAL @1611EER. 5. GRAVITY BAOMRAPT DAMPER 4. INTERLOCK MMN T0440STAT SEr TO 60 MORESS ADJ. S. SPRIN6 ISOLATION HANSM AIR DEVICE 50HEDULE "M46. MIM MODE. • TYPE MATEFUAL FINISH REMARIcg SI REMARK I REMARK I CEIL.IN6 SUPPLY 5 CONE FACE, 245QO STEEL PER ARCH I RI REMARK I RI34W I CEIUN6 RETURN PERFORATED, 24'44" STEEL PER ARCH I NOTES, BARKS, A MAx NC LEVEL OF DIPIFUSERS TO BE 50. 1. MATCH BUILDING STANDARDS B. ACCEPTAEI.E MANUFACTURERS ARE: PRICE, TITUS, NAILOR, METALAIRE C. MAME AND BORDER TYPES TO MATCH CEILING AND/OR WALL. D. DICE ARCa•NTECTURAL RI:'FI.ECTTVE C LING KAL NOTE: CONTRACTOR TO VERIFY EXISTING TAP SIZES AND NOTIFY LANDLORD IF REPLACEMENT IS REQUIRED. REFER TO SCHEDULE BELOW. CAP ALL UNUSED TAPS FLUSH. EXISTING TO REMAIN SUPPLY DUCT SUPPLY DUCT SPIN -IN TAP WITH MANUAL VOLUME DAMPER (MINIMUM 3'-0" FROM SOURCE) N-4 EXTEND DUCTWORK AS ' INLET SIZE REQUIRED. MAXIMUM OF fro INLET SIZE CFMDIFF RANGE FLEX DUCT FOR 10"o DIFFUSER CONNECTION. 6"o 0-110 CFM 8"o 115-240 CFM 10"0 245-400 CFM 12"o 405-700 CFM 14"o 705-1000 CFM AIR DEVICE CFM RANGE 0-240 CFM 245-400 CFM 405-700 CFM 705-1000 CFM ALL NEW DUCTWORK NECK SIZES TO BE 8"O AND LARGER 3 SUPPLY DIFFUSER CONNECTION DETAIL SCALE NOT TO SCALE 5400 LBJ Freeway Suite 125 Dallas, Texas 75240 P. 972.770.2222 F. 972.770.2242 www.entosdesign.com Ff R©SS McFARLAND 9'� 108752 ek,� CONTRACTOR SHALL COORDINATE MEP DRAWINGS WITH ALL OTHER DISCIPLINES ..j 0 0 M Texas Registered Engineering Firm F-9218 5020 Tennyson Parkway - Plano, TX 75024 o Dallas / Fort Worth 214.432.3030 cn Houston 832.532.2007 For Permit 06/06/2019 For Review 06/04/2019 No. Issued Date Project Novus Academy Project ID: 19-1064-L001 Location Grapevine III 3400 William D. Tate Ave Grapevine, Texas 76051 Sheet Title Mechanical Floor Plan Sheet Number 02019 (�J U UIRI (R) (R) I�I(R) u O CLASSROOM 10 CLASSROOM 9 CLASSROOM 8 CLASSROOM 7 rDAYIIGHT ZONE ------------------------------------------------- BRE:AKROOM (R) (R) I�1 L� u 0 — o 0 0 f D F IZ IN 1= o u MECHANICAL o fff CLA SROOM I I I OFFICE I I ul I I . I I I STORAG J �� I I I I I OFFICE I I . I I I I I I CLASSROOM - I — I I 1 I I OFFICE . u U 0 0 Z_ O 31 O MEN �' WOMEN O �' O . O RD O RCC - 7�a_ utKl �(R) 1 1 STOR OFFICE ou o u CONFERENCE N.I.C. COMMONS u u u �J I OFFICE — FIRE ALARM _ u r__V L_ I THERAPY OFFICE STOR 1 zI COPY (R) l�J (R) I k:�11� 0l t�l y I U I U U ® 0 ®U L_� IK► �� (R) L_- I(R) I u � �-- CLASSROOM 1 I08 _.1 CLASSROOM 5 08 08 I 1 L (R) (R) (R) =(R) (R) i I I CLASSROOM 6 CLASSROOM 4 CLASSROOM_ CLASSROOM 2 L----------------------------------------------------------------------------------------------------- - -----� 1 I�J (R) (R) I�J (R) .J (R) L�J L..J (R) O� I ELECTRICAL JAN. SERVER RM. u NORTH 1 FLOOR PLAN - LIGHTI SCAM VT * 1-Or 2 1 /8"x4" SQ, JUNCTION BOX 0 FLEXIBLE CONDUIT CONNECTOR GENERAL NOTES: A. CONTRACTOR TO UTILIZE EXISTING LIGHTING CIRCUITS WHERE AVAILABLE TO PROVIDE SWITCHING PATTERNS AS SHOWN. CONTRACTOR TO PROVIDE NEW 20A/1P CIRCUIT BREAKERS FOR LIGHTING CIRCUITS IF ADDITIONAL ARE REQUIRED. VERIFY MAXIMUM OF 16A PER CIRCUIT. UPDATE PANEL DIRECTORY WHEN WORK IS COMPLETED. B. COORDINATE ALL SWITCH LOCATIONS/SWITCH PATTERNS WITH TENANT/ARCHITECT PRIOR TO INSTALLATION. C. PER NEC 410, ALL FIXTURES WITH DOUBLE ENDED LAMPS AND CONTAIN BALLAST(S) THAT ARE SERVICED IN PLACE SHALL BE INSTALLED WITH INTERNAL OR EXTERNAL DISCONNECTING MEANS THAT SIMULTANEOUSLY DISCONNECTS ALL CONDUCTORS INCLUDING THE GROUNDED CONDUCTOR. EXTERNAL DISCONNECTS MUST BE INSTALLED ADJACENT TO EACH CORRESPONDING FIXTURE AND THE LINE SIDE TERMINALS MUST BE GUARDED. D. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL SYMBOL LEGENDS, DEMOLITION, CONSTRUCTION NOTES AND LIGHTING SPECIFICATIONS. E. LIGHTING FIXTURES AND EXIT SIGNS TO MATCH BUILDING STANDARD. CONTRACTOR SHALL FIELD VERIFY. F. EXISTING LIGHT FIXTURES TO REMAIN, UNLESS NOTED OTHERWISE. CONTRACTOR TO VERIFY ALL EXISTING AND RELOCATED LIGHT FIXTURE COMPONENTS ARE IN PROPER WORKING ORDER. CLEAN, REPLACE AND RE -LAMP AS REQUIRED. VERIFY EXACT LOCATION IN FIELD. KEY NOTES: O CONTRACTOR TO TIE RELOCATED LIGHT FIXTURES TO EXISTING LIGHTING CIRCUIT AND CONTROLS. VERIFY NEW LIGHTING LOAD DOES NOT EXCEED MAXIMUM OF 16A ON CIRCUIT. COORDINATE WITF BUILDING ARCHITECT FOR EXACT SPECIFICATIONS PRIOR TO ROUGH -IN. ��e�.��iS / LL.N �1 ,1V�77da�/ SffA•�G. �'� /.r✓ iGGp/2O (,.r�/� �-foG /.�G .��G /oO to K l r -,;,5;!l jA1,4 A10 !LL. U•'a/!1,47701V S1.14z L o2 0 ,rvI7;;V z421� s aIJF_,'� - - ----------------- �'�--- r ��,0�- �Qo,-t���•i�t_ �:p L4 ^NDUIT TO OTHER TURES, PANEL OR AS WIRED _XIBLE CONDUIT TO HER FIXTURES AS QUIRED 'C # 12, 6'-0", 1 /2" _XIBLE CONDUIT (3RD RE IS GROUND INDUCTOR) CEILING FLEXIBLE CONDUIT CONNECTOR SUSPENSION—,\ SUPPORT FIXTURE AT CEILING GRID SUSPENDED CEILING 2 TYPICAL RECESSED FIXTURE DETAIL SCAM NONE 5400 LBJ Freeway Suite 125 Dallas, Texas 75240 P. 972.770.2222 F. 972.770.2242 www.entosdesign.com F ROSS McFARLAND 1..p .....................I."*, .o 108752 ��0,� �' /C Qrrj �Ar rid t`:�`9;zr E� `�•�'`M CONTRACTOR SHALL COORDINATE MEP DRAWINGS WITH ALL OTHER DISCIPLINES •l 0 Texas Registered Engineering Firm F-9218 *� 5020 Tennyson Parkway - Plano, TX 75024 0 Dallas / Fort Worth 214.432.3030 0 Houston 832.532.2007 a For Permit For Review No. Issued Project Novus Academy Project ID: 19-1064-L001 Location Grapevine III 3400 William D. Tate Ave Grapevine, Texas 76051 Sheet Title Lighting Floor Plan Sheet Number E = I 06/06/2019 06/04/2019 Date 02019 Tnn 80" F/Njs 48" MAX. yFO Fro off, U0, O1 MOUNT 80" TO BOTTOM OF JUNCTION BOX FOR FIRE ALARM HORNS, STROBE LIGHTS AND COMBINATION HORN & STROBE. O2 MOUNT 48" TO TOP OF JUNCTION BOX FOR SWITCHES, FIRE ALARM PULL STATIONS AND OTHER CONTROLS (THERMOSTATS, ETC.) OMOUNT 18" TO CENTER OF JUNCTION BOX FOR RECEPTACLES (ALL TYPES EXCEPT COUNTER TOP MOUNTED), COMPUTER OUTLETS AND TELEPHONE OUTLETS. 4 ADA REQUIREMENTS DETAIL SCALE: NONE CLASSROOM 10 }0+48 qp L I f MECHANICAL FF Q -/I @CR © a CLASSROOM OFFICE � �bv STORAGE _ OFFICE b I CLASSROOM Q OFFICE +48 P b zkzk(p 0(pq CR 4 b ,� b qp �, 0 b .. .. .:b . .� ,.b .. 0- CLASSROOM 9 CLASSROOM 8 CLASSROOM 7 BREAKROOM L1A2-42 LlA1-30 a �O fl fl + MEN � °CJ WOMEN 9 -0" C) O F, E0 ------------ r r L2A2b� ®L2A1 O I I O �r 1 ELECTRICAL JAN. d L2A2-41 1 F-1 � 2 FIRE ALARM SERVER RM. THERAPY OFFICE STOR COPY � D P 0 Zfl�r L1 -40 qp0 OFFICE STOR � p v b 0 CONFERENCE N.I.C. COMMONS a L1A2-40 0 0 OFFICE I L2A2-39 CLASSROOM 1 CLASSROOM 6 CLASSROOM 5 CLASSROOM 4 CLASSROOM 3 CLASSROOM 2 L2A2-33 L2A2-35 L2A2-37 —� 00 NORTH cFLOOR PLAN - POWER SCALE: Vir of -Or MOUNTING -STRAP GREEN HEX HEAD - GROUNDING SCREW fGROUNDED METAL OUTLET rd, BOX BONDING JUMPER BUILDING GROUND �- (green wire) STANDARD GROUND RECEPTACLE 3 RECEPTACLE GROUNDING DETAIL SME: NONE E PARTITION BETWEEN ROOMS ' ELECTRICAL DEVICES — SEE PLAN FOR /PLACEMENT PROVIDE PUTTY PACKS ON BACK OF OUTLETS (TYP. 0 DRYWALL PARTITIONS) WOOD STUD BETWEEN ELEC. DEVICES TO LIMIT SOUND TRANSMISSION BTWN. ! ROOMS AND OFFSET BY 8" MINIMUM ELECTRICAL DEVICES — SEE PLAN FOR PLACEMENT PROVIDE PUTTY PACKS ON BACK OF OUTLETS (TYP. 0 DRYWALL PARTITIONS) 2 ELECTRICAL DEVICE PLACEMENT DETAILWAM NONE GENERAL NOTES: A. ALL CIRCUIT NUMBERS SHOWN FOR LOCATION AND QUANTITY ONLY. VERIFY EXACT NUMBERS IN FIELD. CONTRACTOR TO UTILIZE ALL CIRCUITS MADE AVAILABLE 8Y DEMOLITION ALONG WITH ALL AVAILABLE SPARES AND SPACES TO COMPLETE LAYOUT AS SHOWN. CONTRACTOR TO VERIFY ADDITIONAL LOAD DOES NOT EXCEED PANEL CAPACITY. CONTACT AOS-ENGINEERING IF DISCREPANCY OCCURS. UPDATE PANEL SCHEDULES WHEN WORK IS COMPLETED. B. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL SYMBOL LEGENDS, DEMOLITION, CONSTRUCTION NOTES AND POWER SPECIFICATIONS. C. CONTRACTOR IS TO FIELD VERIFY EXACT LOCATION OF EXISTING PANELBOARDS AND ROUTING OF BRANCH CIRCUITS WITH BUILDING ENGINEER PRIOR TO SUBMITTING BID. D. TURN OFF ALL "SPARE' CIRCUIT BREAKERS AND LABEL. E. COORDINATE ELEVATION AND LOCATION OF ALL RECEPTACLES AND TELE/DATA DEVICES WITH ARCHITECTURAL ELEVATIONS, CASEWORK SHOP DRAWINGS AND EQUIPMENT INSTALLATION DRAWINGS. F. ALL 120-VOLT BRANCH CIRCUITS SHALL BE 3-WIRE (HOT, NEUTRAL AND GROUND). WHERE HOMERUN IS SHOWN TO SERVE A SINGLE DEVICE, THE BRANCH CIRCUIT SHALL HAVE DEDICATED GROUND AND NEUTRAL CONDUCTORS. G. LABEL ALL ELECTRICAL OUTLETS WITH PRINTED TAPED LABEL. H. PROVIDE DEEP DOUBLE GANG JUNCTION BOX WITH SINGLE GANG PLASTER RING WITH (1) 3/4%. FROM EACH TELEPHONE, DATA OR COMMUNICATION OUTLET INDIQATED, TO ABOVE ACCESSIBLE CEILING AND CAP. CONDUIT SHALL INCLUDE 1 /4" POLYPROPYLENE PULL WIRE INSTALLED IN EMPTY CONDUIT. I. ALL LOW VOLTAGE CABLING SHALL BE HUNG AND SECURED VIA J-HOOKS (CABOLFIL CJ OR CJHP) OR CABLE TRAYS (CABOLFIL CF105), OR APPROVED EQUALS. CONTRACTOR TO SUSPEND WIRE TO STRUCTURE AS HIGH AS POSSIBLE. COORDINATE EXACT ROUTING PATHWAYS WITH ARCHITECT. COORDINATE MOUNTING EQUIPMENT SELECTIONS WITH ARCHITECT PRIOR TO ROUGH -IN. J. CONTRACTOR TO PROVIDE CODE MINIMUM FIRE ALARM SYSTEM. INSTALLATION SHALL MEET ALL APPLICABLE LOCAL, STATE, AND NATIONAL CODES. VERIFY ALL FIRE ALARM DEVICE LOCATIONS WITH ARCHITECT PRIOR TO INSTALLING BOXES. K. COORDINATE WITH MECHANICAL AND PLUMBING CONTRACTOR FOR ALL EQUIPMENT BEING REMOVED. ELECTRICAL CONTRACTOR SHALL DISCONNECT AND REMOVE BRANCH CIRCUITING BACK TO SOURCE, REFER TO MEP COVER SHEET FOR DEMOLITION NOTES AND REQUIREMENTS. L. VERIFY EXACT LOCATION OF ALL MECHANICAL AND PLUMBING EQUIPMENT WITH MECHANICAL AND PLUMBING CONTRACTOR PRIOR TO INSTALLATION. M. PROVIDE POWER TO ALL NEW FIRE ALARM, HVAC AND VAV BOXES/DAMPER/ETC. IF EQUIPMENT REQUIRES 120V AC POWER, PROVIDE POWER FROM NEAREST 120V GENERAL PURPOSE RECEPTACLE CIRCUIT OR EXISTING VAV BUILDING CONTROL CIRCUIT. IF EQUIPMENT REQUIRES DC POWER, DUPLICATE POWER CONNECTIONS OF EXISTING VAV'S/DAMPERS IN BUILDING. VERIFY EXACT POWER REQUIREMENTS OF ALL VAV'S/DAMPERS IN FIELD. PERFORM ALL NECESSARY WORK AND PROVIDE ALL NECESSARY MATERIALS FOR A COMPLETE AND FULLY FUNCTIONAL SYSTEM. VERIFY LOCATIONS/QUANTITIES OF ALL VAV'S/DAMPERS WITH MECHANICAL PLANS AND MECHANICAL CONTRACTOR. PROVIDE LOCAL DISCONNECTS AS REQUIRED PER CODE. COORDINATE ANY CONNECTIONS TO BUILDING CONTROL SYSTEMS WITH BUILDING ENGINEER. N. EXISTING TO REMAIN DEVICES SHOWN GRAYED OUT ( 0 ). CONTRACTOR TO VERIFY ALL COMPONENTS ARE IN PROPER WORKING ORDER. CLEAN AND REPLACE AS REQUIRED. VERIFY EXACT LOCATION IN FIELD. KEY NOTES: O ALL EXISTING ELECTRICAL EQUIPMENT TO REMAIN, UNLESS NOTED OTHERWISE. CONTRACTOR TO VERIFY EXACT LOCATIONS. O Fes.. SHALL BE CONTROLLED THERMOSTATICALLY. CONNECT Td NEAREST GENERAL POWER BRANCH CIRCUIT. COORDINATE WITH MECHANICAL CONTRACTOR FOR EXACT REQUIREMENTS PRIOR TO ROUGH -IN. FIRE ALARM NOTE THE FIRE ALARM CONTRACTOR IS RESPONSIBLE FOR DESIGN, DESIGN APPROVAL, INSTALLATION AND FINAL ACCEPTANCE BY THE AUTHORITIES HAVING JURISDICTION. FINAL DEVICE QUANTITIES AND LOCATIONS ARE THE RESPONSIBILITY OF THE CONTRACTOR. 5400 LBJ Freeway Suite 125 Dallas, Texas 75240 P. 972.770.2222 F. 972.770.2242 www.entosdesign.com 108752 /q. At EN�cC' CONTRACTOR SHALL COORDINATE MEP DRAWINGS WITH ALL OTHER DISCIPLINES z Texas Registered Engineering Finn F-9218 m 5020 Tennyson Parkway - Plano, TX 75024 o Dallas / Fort Worth 214.432.3030 0 Houston 832.532.2007 a For Permit 06/06/2019 For Review 06/04/2019 No. Issued Date Project Novus Academy Project ID: 19-1064-L001 Location Grapevine III 3400 William D. Tate Ave Grapevine, Texas 76051 Sheet Title Power Floor Plan Sheet Number 02019 E = 2