HomeMy WebLinkAboutROOF2025-004294ADDRESS
2100 W Northwest Hwy.,
202
Grapevine, TX 76051
LEGAL
Grapevine Plaza
Addition-Gpv Blk n/a Lot
4
S
PERMIT HOLDER
Scott Manning
Paragon Roofing, LLC
(214) 630-6363
COLLABORATORS
•Scott Manning
Paragon Roofing, LLC
(214) 630-6363
OWNERS
•Park Place Shopping
Cntr Ltd
(214) 720-6605
TENANTS
•Vacant C/O
INSPECTIONS 1
1. Building Final
INFORMATION FIELDS
**APPLICANT NAME (Individual)Andrew Gonzalez
**APPLICANT PHONE NUMBER 602-919-4839
VALUATION 220215
Square Footage 26200
DOCUMENTS - MISC 01 Assembly Letter 8185206 Park Place
Shopping Center.pdf
FEE TOTAL PAID DUE
*Building Permit Fee (Value)$ 2,006.25 $ 2,006.25 $ 2,006.25
TOTALS $ 2,006.25 $ 2,006.25 $ 0.00
READ AND SIGN
I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF
MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO
THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN
COMPLIANCE WITH THE CITY OF GRAPEVINE ORDINANCE REGULATING
CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT
DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR
ORDINANCE OF THE CITY OF GRAPEVINE.
November 14, 2025
Signature Date
City of Grapevine
PO Box 95104
Grapevine, Texas 76099
817) 410-3166
Building - Roofing
Project # 25-004294
Project Description: this project is a "Roof Recovery", we are
leaving the existing roof in place and adding additional layers on
top of the existing roof. the items we will be adding are a 1/2"
ProtectoR HD Roof Board (4x8 boards) attached with High Load
Fasteners and JM TPO Rhino plates with the attachment…
pattern of field 6 / perimeter 6 / corner 9, next we will be
attaching a single layer of JM 60Mil TPO with Rhino plate
induction heat welded [ELECTRONIC REVIEW]Issued on: 11/14/2025 at 8:31 AM
MYGOV.US 25-004294, 11/14/2025 at 8:31 AM Issued by: Amanda Robeson
Page 1/2
City of Grapevine Building - Roofing
Project # 25-004294
NOTICES
ALL work must be done in compliance with the 2021 INTERNATIONAL BUILDING CODE. All work issued
prior to January 1, 2024, must be done in compliance with the 2006 INTERNATIONAL BUILDING CODE.
NOTES
> 24 HOUR INSPECTION NUMBER
METRO (817) 410-3010, CUT OFF TIME FOR A.M. INSPECTION IS 7:30 A.M. --- CUT OFF TIME FOR P.M.
INSPECTION IS 12:30 P.M.
> PERMIT ISSUED IN ACCORDANCE WITH APPLICATION ON FILE IN THIS OFFICE.
THIS PERMIT SHALL EXPIRE IF WORK IS NOT COMMENCED WITHIN (180 DAYS) OF ISSUANCE OR IF
WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF (180 DAYS). THE ISSUANCE OR
GRANTING OF THIS PERMIT AND / OR APPROVAL OF PLANS, SPECIFICATIONS AND
COMPUTATIONS SHALL NOT BE CONSTRUED TO BE A PERMIT FOR, OR AN APPROVAL OF, ANY
VIOLATION. THE PROVISIONS OF THE CODES AND ORDINANCES OF THE CITY OF GRAPEVINE. THE
ISSUANCE OF A PERMIT BASED ON PLANS, SPECIFICATIONS, AND OTHER DATA SHALL NOT
PREVENT THE BUILDING DEPARTMENT FROM THEREAFTER REQUIRING THE CORRECTION OF
ERRORS IN SAID PLANS, SPECIFICATIONS, AND OTHER OR REQUIRING CORRECTIONS OF THE
CONSTRUCTION ITSELF.
> NOTICE: An Inspection of the vented appliances will be required for ALL roof repair or replacement.
Access to the interior of the structure is required.
MYGOV.US 25-004294, 11/14/2025 at 8:31 AM Issued by: Amanda Robeson
Page 2/2
21
ASCE 2016 (Less than 60')
Perimeter and Corner Dimensions:
For buildings less than 60 ft in height
Zone 3 (Corners)
0 "U shaped with legs 0.6 times the building height long, and 0.2 times the building height wide
Zone 2 (Perimeters)
* 0.6 times the height of the building
Zone I (Field)
0.6 times the height of building (note — this brings the inner boundary of field to 1.2 times the height of
the building from all edges.
Zone 1'(Field Prime)
* Any area remaining (note — this zone is not always present depending on building size/shape)
Menffiq
111111!!l11;l1!!1j1 1111111IR1 11111111, . I . I .
Ensure any whole or partial insulation board that falls within the calculated perimeter or corner has the increased
securement applied over the entire board. This must also be true for any roof cover/base sheet width when the roll
is parallel to the building edge.
Performance/Technical Information
# Attachment densities are consistent with FM 1-90 wind uplift resistance.
Installation Notes
0 For additional installation guidelines and considerations, please visit https://www.i,m,com/en/commercial-
roofina/specs-and-details]
Johns Manville is a manufacturer of commercial roofing products and offers this general conceptual information to you as a courtesy. This
complimentary assistance is not to be used or relied upon by anyone as a substitute for professional engineering design or documentation
requtred by building code, contract or applicable law By accepting these comments you agree they do not constitute any representations,
endorser nents of or an assumption by Johns Manville of any liability for either the adequacy of the design of this building or of any inatenal not
supplied by Johns Manville These comments are for Johns Manville Guarantee purposes only. Additional r9quirenrents may be necessary A4 Public
determined by contract documents_ building code and regulations, or governing entity.
3 1 :: :
Listed below are recommendations for installation of products only if included in the proposed roof
assembly
Attachment Method or Product Recommendation
• All wet/damaged materials must be completely
Materials Left In Place removed and replaced.
• All flashing must be removed, all drains cut out,
and new, sumps installed,
Owner responsible for removal an
d " dreinstallation of
Overburden any/all overburn products should a roof leak occur
and require repair.
a certified Johns Manville contractor and inspected and approved by a Johns Manville Technical Representative.
All materials supplied or marketed by Johns Manville will be covered under the terms and conditions of this
agreement.
Thank you for your interest in our roofing products and services. Please contact Johns Manville if any information
is incomplete or incorrect so that appropriate modifications can be made,
Johns Manville Technical Services
Roofing Systems Group
10100 W Ute Ave
Littleton, CO 80127
800-922-5922 Option 3
Johns Manville is a manufacturer of commercial roofing products and offers this general conceptual information to you as a courtesy. This
complimentary assistance is not to be used at relied upon by anyone as a substitute for, professional engineering design or documentation
required by building code, contract or applicable law By accepting these comments you agree they do not constitute any representations,
endorsements of, or an assumption by Johns Manville of any liability for either the adequacy of the design of this building or of any material not
supplied by Johns P.4anville These comments are for Johns Manville Guarantee purposes only Additional requirements may be necessary A4 Public
determined by contract documents. building code and regulations, or governing entity