Loading...
HomeMy WebLinkAboutROOF2025-004294ADDRESS 2100 W Northwest Hwy., 202 Grapevine, TX 76051 LEGAL Grapevine Plaza Addition-Gpv Blk n/a Lot 4 S PERMIT HOLDER Scott Manning Paragon Roofing, LLC (214) 630-6363 COLLABORATORS •Scott Manning Paragon Roofing, LLC (214) 630-6363 OWNERS •Park Place Shopping Cntr Ltd (214) 720-6605 TENANTS •Vacant C/O INSPECTIONS 1 1. Building Final INFORMATION FIELDS **APPLICANT NAME (Individual)Andrew Gonzalez **APPLICANT PHONE NUMBER 602-919-4839 VALUATION 220215 Square Footage 26200 DOCUMENTS - MISC 01 Assembly Letter 8185206 Park Place Shopping Center.pdf FEE TOTAL PAID DUE *Building Permit Fee (Value)$ 2,006.25 $ 2,006.25 $ 2,006.25 TOTALS $ 2,006.25 $ 2,006.25 $ 0.00 READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE ORDINANCE REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. November 14, 2025 Signature Date City of Grapevine PO Box 95104 Grapevine, Texas 76099 817) 410-3166 Building - Roofing Project # 25-004294 Project Description: this project is a "Roof Recovery", we are leaving the existing roof in place and adding additional layers on top of the existing roof. the items we will be adding are a 1/2" ProtectoR HD Roof Board (4x8 boards) attached with High Load Fasteners and JM TPO Rhino plates with the attachment… pattern of field 6 / perimeter 6 / corner 9, next we will be attaching a single layer of JM 60Mil TPO with Rhino plate induction heat welded [ELECTRONIC REVIEW]Issued on: 11/14/2025 at 8:31 AM MYGOV.US 25-004294, 11/14/2025 at 8:31 AM Issued by: Amanda Robeson Page 1/2 City of Grapevine Building - Roofing Project # 25-004294 NOTICES ALL work must be done in compliance with the 2021 INTERNATIONAL BUILDING CODE. All work issued prior to January 1, 2024, must be done in compliance with the 2006 INTERNATIONAL BUILDING CODE. NOTES > 24 HOUR INSPECTION NUMBER METRO (817) 410-3010, CUT OFF TIME FOR A.M. INSPECTION IS 7:30 A.M. --- CUT OFF TIME FOR P.M. INSPECTION IS 12:30 P.M. > PERMIT ISSUED IN ACCORDANCE WITH APPLICATION ON FILE IN THIS OFFICE. THIS PERMIT SHALL EXPIRE IF WORK IS NOT COMMENCED WITHIN (180 DAYS) OF ISSUANCE OR IF WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF (180 DAYS). THE ISSUANCE OR GRANTING OF THIS PERMIT AND / OR APPROVAL OF PLANS, SPECIFICATIONS AND COMPUTATIONS SHALL NOT BE CONSTRUED TO BE A PERMIT FOR, OR AN APPROVAL OF, ANY VIOLATION. THE PROVISIONS OF THE CODES AND ORDINANCES OF THE CITY OF GRAPEVINE. THE ISSUANCE OF A PERMIT BASED ON PLANS, SPECIFICATIONS, AND OTHER DATA SHALL NOT PREVENT THE BUILDING DEPARTMENT FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS, AND OTHER OR REQUIRING CORRECTIONS OF THE CONSTRUCTION ITSELF. > NOTICE: An Inspection of the vented appliances will be required for ALL roof repair or replacement. Access to the interior of the structure is required. MYGOV.US 25-004294, 11/14/2025 at 8:31 AM Issued by: Amanda Robeson Page 2/2 21 ASCE 2016 (Less than 60') Perimeter and Corner Dimensions: For buildings less than 60 ft in height Zone 3 (Corners) 0 "U shaped with legs 0.6 times the building height long, and 0.2 times the building height wide Zone 2 (Perimeters) * 0.6 times the height of the building Zone I (Field) 0.6 times the height of building (note — this brings the inner boundary of field to 1.2 times the height of the building from all edges. Zone 1'(Field Prime) * Any area remaining (note — this zone is not always present depending on building size/shape) Menffiq 111111!!l11;l1!!1j1 1111111IR1 11111111, . I . I . Ensure any whole or partial insulation board that falls within the calculated perimeter or corner has the increased securement applied over the entire board. This must also be true for any roof cover/base sheet width when the roll is parallel to the building edge. Performance/Technical Information # Attachment densities are consistent with FM 1-90 wind uplift resistance. Installation Notes 0 For additional installation guidelines and considerations, please visit https://www.i,m,com/en/commercial- roofina/specs-and-details] Johns Manville is a manufacturer of commercial roofing products and offers this general conceptual information to you as a courtesy. This complimentary assistance is not to be used or relied upon by anyone as a substitute for professional engineering design or documentation requtred by building code, contract or applicable law By accepting these comments you agree they do not constitute any representations, endorser nents of or an assumption by Johns Manville of any liability for either the adequacy of the design of this building or of any inatenal not supplied by Johns Manville These comments are for Johns Manville Guarantee purposes only. Additional r9quirenrents may be necessary A4 Public determined by contract documents_ building code and regulations, or governing entity. 3 1 :: : Listed below are recommendations for installation of products only if included in the proposed roof assembly Attachment Method or Product Recommendation • All wet/damaged materials must be completely Materials Left In Place removed and replaced. • All flashing must be removed, all drains cut out, and new, sumps installed, Owner responsible for removal an d " dreinstallation of Overburden any/all overburn products should a roof leak occur and require repair. a certified Johns Manville contractor and inspected and approved by a Johns Manville Technical Representative. All materials supplied or marketed by Johns Manville will be covered under the terms and conditions of this agreement. Thank you for your interest in our roofing products and services. Please contact Johns Manville if any information is incomplete or incorrect so that appropriate modifications can be made, Johns Manville Technical Services Roofing Systems Group 10100 W Ute Ave Littleton, CO 80127 800-922-5922 Option 3 Johns Manville is a manufacturer of commercial roofing products and offers this general conceptual information to you as a courtesy. This complimentary assistance is not to be used at relied upon by anyone as a substitute for, professional engineering design or documentation required by building code, contract or applicable law By accepting these comments you agree they do not constitute any representations, endorsements of, or an assumption by Johns Manville of any liability for either the adequacy of the design of this building or of any material not supplied by Johns P.4anville These comments are for Johns Manville Guarantee purposes only Additional requirements may be necessary A4 Public determined by contract documents. building code and regulations, or governing entity