HomeMy WebLinkAboutSFRA2025-003903RECEIVED: 10/13/2025 DATE OF ISSUANCE:•
25-003903
2923 Canyon Dr PERMIT #: 25-003903
INSTALL (10) PILINGS FOR FOUNDATION ELECTRONIC REVIEW
BUILDING PERMIT APPLICATION
(TLE SE PRENF17 LEGIBLY— CONiMETE ENTIRE FOWNf}
JOB ADDRESS: 2923 Canyon sum .# Text
LOT: BLOCK: SUBDIVISION:
BUILDING CONTRACTOR (company name): Structured Foundation Repairs
CURRENT MAILING ADDRESS: 13301 Trinity Blvd #133
CITY/STATE/ZIP: Euless pH; # 9724841200
Fay #
PROPERTY OWNER: Savannah Templet n
CURRENT MAILING ADDRESS: 7923 C_ A Tun _
CITY/STATE/ZIP: G ra0avi nQ Tx 7svix;l PHONE NUMBER: 9724u 20
PROJECT VALUE: $ 12, ms • AN FIRE SPRINKLERED? YES NO x_
WHAT TRADES WILL BE NEEDED? cCiea ones that I ELECTRIC PLUMBING MECHANICAL, _
DESCRIPTION OF WORK TO BE DONE: install 10 concrete pilings to stabilize foundation
USE OF BUILDING OR STRUCTURE: rPs i d ,n r P
NAME OF BUSINESS:
Total Square Footage under roof: Square Footage of alteration/addition: —Q a � q f +
❑ I hereby certify that plans have been reviewed and the building will be inspected by a certified energy code inspector in accordance with
State Law. Plan review and inspection documentation shall be made available to the Building Department (required for new buildings,
alterations and additions)
❑ I hereby certify that plans have been submitted to the Texas Department of Licensing and Regulation for Accessibility Review.
Control Number: (Not required for 1 & 2 family dwellings)
❑ I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas
Department of Health.
(REQUIRED FOR DEMOLITIONS, ADDITIONS AND OR ALTERATION TO COMMERCIAL AND PUBLIC BUILDINGS)
I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by
the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. It is understood that the issuance of
this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. I FURTHERMORE UNDERSTAND
THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY, AND THAT THE
DESIGN PROFESSIONALIOWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL THE APPROPRIATE STATE AND
OR FEDERAL AGENCY(S).
PRINT NAMlr
E: ay ra I Pa n rl Pv SIGNATURE�OM
PHONE #: Q72dpd1 7A01 EMAIL: prmi is@a
IF PREFERRED TO BE CONTACTED BY E-MAIL
THE FOLLOWING IS TO BE COMPLETED BY THE BUILDING INSPECTION DEPARTMENT 1
Construction Type: V j3 1 Permit Valuation: $ Setbacks Approval to Iss
Occupanc}- Group: Fire Sprinkler: YES NO Front: Electrical %
Division: _ Building Depth: I Left: Plumbing -
Zoning: Z ��? . Building Width: Rear: Mechanical
Occupancy Load: Right:
Plan Review Approval: Y%..,, -rp%— Date: 10-'40-2-5 Building Permit Fee: 150.00 j
Site Plan Approval: Date: Plan Review Fee:
Fire Department: Date: Lot Drainage Fee:
Public Works Department: Date: Sewer Availability Rate:
Health Department: Date: Water Availability Rate:
Approved for Permit: Date: Total Fees:
Lot Drainage Submitted: Approved: Total Amount Due: 150.00
P.O. BOX 96104. GRAPEVINE TX 7609016171 4100.3106 O:FORWDSPEPURAPPMATIONS t W-ReV.11 5pa.2bP.11ftAh1
City of Grapevine Building - Residential
PO Box 95104 AlterationkTV jE
Grapevine, Texas 76099 *tf
s
817) 410-3166 Project # 25-003903
Project Description: 2923 Canyon install 10 concrete pilings to
stabilize foundation (ELECTRONIC REVIEW]
Issued on: 10/21/2025 at 8:13 AM
ADDRESS INSPECTIONS 1
2923 Canyon Dr.
Grapevine, TX 76051 1. Building Final
LEGAL
INFORMATION FIELDS
Oak Creek Est BIk 9 Lot
17
**APPLICANT NAME (Individual)
Thomas Kidd
*01985213`
**APPLICANT PHONE NUMBER
9724841200
APPLICANT E-MAIL
Permits@structuredfoundation.
Thomas Kidd
VALUATION
12265
Structured Foundation R
Square Footage
gp
epairs, INC.
* CONSTRUCTION TYPE
VB
(972)484-1200
* OCCUPANCY GROUP
R-3
COLLABORATORS
DOCUMENTS - MISC 01
2923 Canyon GRAPEVINE ap.pdf
• Thomas Kidd
DOCUMENTS - MISC 02
2923 Canyon Rd. Grapevine Texas.pdf
Structured Foundation
Repairs, INC.
* ZONING DISTRICT
R.7.5
(972) 484-1200
FEE
TOTAL PAID DUE
OWNERS
Building Permit Fee, ($150.00
• Brandon Templeton
Flat Fee) Simple Alteration
$ 150.00 $150.00 $150.00
TOTALS
$150.00 $150.00 $ 0.00
READ AND SIGN
I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF
MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO
THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN
COMPLIANCE WITH THE CITY OF GRAPEVINE ORDINANCE REGULATING
CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT
DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR
ORDINANCE OF THE CITY OF GRAPEVINE.
I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE
NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY AND THAT
THE DESIGN PROFESSIONAL / OWNER IS RESPONSIBLE FOR OBTAINING
SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR FEDERAL
AGENCY(S).
Page 1/2
MYGOV.U$ 25.003903, 1012V2025 at 8:13 AM Issued by: Courtney Cogburn
ALL CHANGES REQUIRE
APPROVAL OF REVISED
1000 Buck Dobbs Rd-, PLANS
Aledo, Texas 76008 �EC
817-374-3559 APPROVED PLANS SHALL BE
Info(a7Nortierilc.com KEPT ON JOBSITE AT ALL TIMES aama pBN[[06 02flRlll3 UL
Initial Reoort for Foundation Assessment
Date: October 7, 2025 r T:wI%�-
MONDAY - SATURDAY ONLY
MO WORK PERMITTED ON SUNDAY
Attention: Structured Foundation Repair (The Client)
CONTRACTOR SH4ll CALL FOR INSPECTIONS
Subject: Foundation Review lenlatoaoto
2923 Canyon Rd., Grapevine. Texas a VE ono uaoN vEaMiT EXPI nl ITIT oNE
Authorization and Scone:
Nortier Engineering Consultants, LLC (NEC) has been retained by the Client to perform an evaluation of
the slab on grade foundation system of the 1 story residential home with brick veneer located at the
subject address referenced above. This report provides guidance as to whether or not the existing
foundation system is in need of repair. The report also proposes a recommended plan if repair are
needed.
Conclusions/Sripcifrc Recommendation
NEC performed a visual evaluation of the foundation for the subject property on 10/7/2025. NEC also
performed a floor survey using a Zip -level Pro-2000 series, collecting relative floor elevations, to aid in
surface topography mapping of the floor(s). Elevations shown are adjusted for the type of flooring
encountered to reflect a consistent measuring plane. The map of the existing floor elevations can be seen
in the figure attached to this report.
Based on review of the foundation, and reasonable professional engineering opinion, we've determined
that movement of the foundation has occurred and should be repaired. Although complete levelness
cannot be guaranteed, or may not be attainable, the proposed plan should improve the performance of the
foundation. it is recommended that ten (10) piers be installed and polyurethane foam be injected as
indicated on the figure(s) attached to this report. Locations of internal piers [if needed] are intended to be
approximate. The Contractor should locate the beams and place internal piers accordingly. Furthermore,
the proposed foundation repairs shall meet or exceed Chapter 4 of the 2021 International Residential
Code (IRC), as it relates to foundations and any local applicable amendments to the IRC.
This report is solely based on information gathered during our site visit on 10/7/2025, and does not take
into consideration any changes in condition of the foundation or soils after the date which the information
was gathered.
CITY GRAPEVINE
THIS PAGE RE QOIFF g7j7))/; 7J(JfJ
RELEA E DOES F!(11A�UiH0f1IL�ANYW(JHK IN
CONFLICT WITH THE BUILDING CODE OR ZONING
ORDINANCE
PROVIDE SIGNED AND SEALED LETTER
CITY APPROVIEID���2 YNB TO BE KEPTON THEJOB
ft AT ALL TIMES.
FROM REGISTERED ENGINEER
CONFIRMING SITE INSPECTION AND
10/20/2025 1:22:43 PM
APPROVAL OF PIER INSTALLATION WHEN
BY: KELLY TAFT TSBPE: 1-3971
WORK IS COMPLETE
BUILDING INSPECTION DIVISION:
RELEASE DOES NOTAPPLY TO CONSTRUCTION IN
EASEMENTS OR PUBLIC RIGHT-OF-WAY
RECEIVED: 10/1312025
25LO03903
ALL CHANGES MUST BE APPROVED.
2923 Canyon Dr
INSTALL (10) PILINGS FOR FOUNDATION
1000 Buck Dobbs Rd,
Aledo, Texas 76008
817-374-3559
Info(a7Noniedle-com
MINCC
General Recomp fnl3aLions
mended :
It is recomt a guttering system be installed if the house does not have gutters. Installing a
guttering system will direct water away from the foundation and reduce the potential for ground erosion
near the foundation footing.
It is also recommended that the plumbing systems be checked after any repairs are made to the foundation
system. Vertical movement of the foundation system can impose stresses on the plumbing infrastructure
and cause leaks.
It is recommended that soil grading be maintained such that the bottom portion of the foundation is below
grade, as per the governing code and a watering system be utilized around the perimeter of the house.
Fluctuations in moisture content of the soils near the foundation of the house can cause differential
movement. If the moisture content is kept consistent, the potential for differential movement is mitigated
Furthermore. grading around the perimeter of the building should be maintained as sloping away from the
foundation at a minimum of 6 inches fall within the first 10 feet from the foundation. Such grading
configuration should prevent localized water accumulating around areas of the foundation. Saturated
soils decline in bearing capacity and can result in differential movement of the foundation.
Limitations:
This report is intended for information purposes only, and the sole use of the client and/or homeowner.
The scope of this report is limited to the items related to the foundation system only, and it is understood
that detection of all existing or potential defects is not feasible for this type of evaluation. The intent of
this report does not include judgment on any of the superstructure, detached buildings, retaining or
privacy walls, concrete reinforcement and/or site drainage. In addition, the scope of this report excludes
material and soil sampling/testing procedures and as such were not performed. The report is not to be
used by others for any purpose without our written consent. Compliance with any code or specification
other than as expressly noted in this report is specifically excluded. It is the responsibility of any
Contractor to abide by any other applicable codes or specifications.
No warranty for any repairs, future foundation performance, structure, vegetation, or soils at the subject
property are offered by this report, nor does this report haply any liability to NEC, nor Daneel Nortier. PE
for any work to be performed as a result of this report. It is understood that soils in this area experience
movement due to moisture fluctuations. Such soil movement could cause the foundation to move after
the recommended repairs have been made. Any provided floor elevation data and recommended actions
are based on soil conditions as they exist at the time of the evaluation. NEC does not warrant or imply
that other problems may not occur in the future. No warranty, expressed or implied is made or intended
and the limit of liability shall be limited to the fee paid for this report at the time of evaluation.
Report Prepared by:
Nortier Engineering Consultants, LLC
Texas Engineering Firm (F-16800)
10/7/2025
Daneel Nortier, P.E.
Professional Engineer (TX#113157)
PROVIDE SIGNED AND SEALED LETTER
FROM REGISTERED ENGINEER
CONFIRMING SITE INSPECTION AND
APPROVAL OF PIER INSTALLATION WHEN
WORK IS COMPLETE
CITY OF GRAPEVINE
THIS PAGE RELEASED FOR CONSTRUCTION
RELEASE DOES NOT AUTHORIZE ANY WORK IN
CONFLICT Wllll THE BUILDING CODE OR ZONING
ORDINANCE
CITY APPROVED PLANS TO BE KEPT ON THE JOB
SITE AT ALL TIMES.
10/20/2025 1:28:38 PM
BY: KELLY TAFT TSBPE: 1-3971
Drive
BUILDING INSPECTION DIVISION:
RELEASE DOES NOT APPLY TO CONSTRUCTION IN
EASEMENTS OR PUBLIC RIGHT-OF-WAY
ALL CHANGES MUST BE APPROVED.
New Pier
i Photograph Label
Oft loft loft
r r I
10/7/25
By: DN
Drive Concrete
I I
.2,3 -1 4 -0.2 0.9 1 7 Polyurethane Foam
0.3 0.2 �Ineclion
Garage
-1.7 -1.6 -02 1.0
-0.5 -5.5 -5.3 -4.3
-0.2
0.1 Y
Zero
-6.0 -5 6
0.2 0.2 09 Recessed
0022
-54 -5.4
oe 0.3 0.2 0.5
fin
-04 -0.1 0.2 �
Aw -0.4 0.6 0.9 WW
PROVIDE SIGNED AND SEALED LETTER
FROM REGISTERED ENGINEER
CONFIRMING SITE INSPECTION AND '..
APPROVAL OF PIER INSTALLATION WHEN
WORK IS COMPLETE
2923 Canyon Dr �CC
Grapevine, Texasxoen v asuAwes mxwu�ers us
CITY OF GRAPEVINE
THIS PAGE RELEASED FOR CONSTRUCTION
RELEASE DOES NOT AUTHORIZE ANY WORK IN
CONFLICT WITH THE BUILDING CODE OR ZONING
ORDINANCE
CITY APPROVED PLANS TO BE KEPT ON THE JOB
SITE AT ALL TIMES
10/20/20# 1:28:51 PM
BY: KELLY TAB T //y' ;
Slab
BUILDING INSPECTION DIVISION'
RELEASE DOES NOT APPLY TO CONSTRUCTION IN
EA SEMENTS OR PUBLIC RIGHTAF..W ---
ALL CHANGES MUST BE APPROVED
NOTES
1) Piles shall be driven to refusal
2) Foundations supporting a 2 story
building shall be supported with
double piers as shown, however, a
single pier may be used if spacing
do" not exceed 6'-W
Ing
N.a
.Top cap"
lid 6" Diameter by 12" long
Precast Concrete Cylinder.
A) Single Pier for 1 Story
B) Double Pier for 2 Story
For normal spacing
PROVIDE SIGNED AND SEALED LETTER (Sae notes for additionalinfonnalion)
FROM REGISTERED ENGINEER
CONFIRMING SITE INSPECTION AND
APPROVAL OF PIER INSTALLATION WHEN
WORK IS COMPLETE
1/21/24 I Precast Concrete Piling Detail Diagram f�CC
Not to Scale NUNTIEN ENSINEENINN CONSULTANTS US
einfarcing steel reps T
CITY OF GRAPEVINE
CONFR TWIT 4EHJB?fL IN CODEORZ KING
CONFLICT WDH THE BUILDING CODE OR ZONING
ORDINANCE
CITY APPROVED PLANS 7n Vj. J.PT ON THE JOB
SITE AT ALL TIMES
10/20/2025 1:24:27 PM
BY: KELLY TAFT TSBPE: 1-3971
BUILDING INSPECTION DIVISION:
RELEASE DOES NOTAPPLY TO CONSTRUCTION IN
EASEMENTS OR PUBLIC RIGHT-OF-WAY
ALL CHANGES MUST BE APPROVED.
PROVIDE SIGNED AND SEALED LETTER
FROM REGISTERED ENGINEER
CONFIRMING SITE INSPECTION AND
APPROVAL OF PIER INSTALLATION WHEN
WORK IS COMPLETE