HomeMy WebLinkAboutMFA2025-004223 ECEIVED: 11/05/2025 DATE OF ISSUANCE:, 2
25-004223 "CAMDEN RIVERWALK -
APARTMENTS" Nov 2 1 25-004223
3900 GRAPEVINE MILLS PKWY #13 PERIIIT #:
REPAIR EXTERIOR BALCONY
B EDITNIG"'ERMIT APPLICATION ELECTRONIC REVIEW
(PLEASE PRIN-r LEGIBLY - CO-1$PLETE EN-rU2E FORAD
JOB ADDRESS' 39006r v+ne Mill-sPirwy
LOT: BLOCK: SUBDIVISION:
BUILDING CONTRACTOR (company name): t
CURRENTMAILINGADDRESS: 112.22 Disco
CITY/STATE/ r .� ;',• , _ _"c r i
PROPERTY OWNER:
CURRENT MAILING ADDRESS:
Crry/STATE/ZIP:
PROJECT VALUE: S
PH. # 2 i 01, 17"",y 0 �y Y .-
SUITE #
Fax #
PHONE N[.rMBER:
FIRE SPRLNIMERED? YES NO
WHAT TRADES WILL BE NEEDED? (C-zeca ones thri rpna y) ELECTRIC PLUMBING MECHANICAL
DESCRIPTION OF WORK TO BE DONE. F,ernove c :,ncr :te, make structural rlcpairr a, r:reded. R72,,,;acc- c, ncra
USE OF BUILDING OR STRUCTURE • rV1 u f ti a n`t i l
NAME OF BUSINESS: Car:iden , iv: rW�. t'. Apartment-, -
Total Square Footage under roof: L -'`- Square Footage of alteration/addition:
O I hereby Certify that plans have been reviewed and the building wW be inspected by a certified energy• code inspector in accordance with
State Law. Plan review and inspection documentation shall be made available to the Building Department (required for new buildings,
alterations and additions)
0 I hereby certify that plans have been submitted to the Texas Department of Licensing and Regulation for Accessibility Review.
Control Number: (Not required for I & 2 family dwellings)
0 I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas
Department of Health.
(REQUIRED FOR DEMOLITIONS, Aor.i Y tart t 6 AND OR ALTERATION TO COtilriIER.CIAL AND PUBLIC BUILDINGS)
I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by
the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. It is understood that the Issuance of
this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. I FUIRTIMWNIORE UNDERSTAND
THAT PLAINS AA1-D SPECIFICATIONS ARE : TOT REVIEWED FOR HANDICAPPED ACCESSIBILrrY BY THE CITY, AND THAT THE
DESIGN PROFESSIONAL/OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND
OR FEDERAL AGEN CY(S).
PPJ NT NAME: `� Q a%" ` SIGNATURE i
PHONE #: ^ ` ^ ` J EMAIL:''
❑ CHECK BOX IF PREFERRED TO BE CONTACTED BY E-MAIL _
THE FOLLOWING IS TO BE COMPLETED BY THE BUEL DIU14G INSPECTION DEPARTNWNT
Construction T)p� Permit Valuation: $ Setbacks Approval t9tIssue
Oc Pancy Grou : —Z. Fire Sprinkler: YES_ _ NO Front: Electrica
Division: _ BuildingDepth: - _ _ �Left: _ Plumb'
Zoning: 1Z — M F — 1 Building Width: _ I Rear: Mecti cal
Occupancy Load: Grease Trap Right:
_Ho
Plan Review Approval: �,Z__
Date: 2V Building Permit Fee:
Site Plan Approval: _ _ _ Date: _ Plan Review Fee:
Fire Department: Date: Lot Dxainage.Fee:
Public Works Department: Date: _ Sewer Availability Rate:
Health Department: Date: Water Availability Rate_
Approved for Permit: Date: Total Fees:
Lot Drainage Submitted: Approved: Total Amount Due: _ 1800.00
5
m
0
m
D
33
M
Z
z
0
m
0
D
CD
r
c
m
m
m
D
nn onY K.n. /`nAnL�n4C TYTCl1oa l4�Tl A�fl if CC
O:FORMSMSPERWAPPUCATIONS IM-Rev.tUP1.5i06.2!07.19109.4i71 at.
LTI
IV
cn
City of Grapevine
Building - Multi -Family VLti',
PO Box 95104
Alteration
Grapevine, Texas 76099
7 E I A 8 .10
817) 410-31W
Project # 25-004223
Project Description: Repair exterior balconies at Units on the
building centers: This includes the following units:1334-
80sgft,1324-80sgft, 1335-80sgft, 1325-80sgft, 1332-80sgft,
1322-80sgft, 1337-80sgft, 1327-80sgM 1333-80sgft, 1336-
80sgft .'Camden Riverwalk Apartments" [ELECTRONIC...
Pr-vlFvdl
Issued on: 11/21/2025 at 2:37 PM
ADDRESS
INSPECTIONS 3
3900 Grapevine Mills
Pkwy 13
1. Building Foundation/Footing 3. Building Final
Grapevine, TX 76051
2. Final Fire Dept Inspection
LEGAL
INFORMATION FIELDS
Riverwalk Addition Blk
is Lot iai
'APPLICANT NAME (individual) Chris Doyle
"APPLICANT PHONE NUMBER 214-794-0861
PERMIT HOLDER
Shannon White
APPLICANT E-MAIL
Hentana Construction
**NAME OF BUSINESS Camden Riverwalk Apartments
(469) 581-8199
VALUATION 16800
COLLABORATORS
Square Footage 1800
• Shannon White
Acreage g0
Hentana Construction
What is use of Building/Structure? Multifamily housing
(469) 581-8199
* CONSTRUCTION TYPE VB
OWNERS
* OCCUPANCY GROUP R-2
• Fund Riverwalk Llc
DOCUMENTS - MISC 01 APPLICATION.pdf
TENANTS
DOCUMENTS - MISC 02 Camden-Riverwalk-Apartments-Site-
Plan -Combined 13.pdf
• Camden Riverwalk
* ZONING DISTRICT R-MF-1
Apartments
(000) 000-0000
FEE
TOTAL PAID DUE
Building Permit Fee, R-2 $1,800.00 $1,800.00 $1,800.00
(Alteration) SF
TOTALS $ 1,800.00 $ 1,800.00 $ 0.00
READ AND SIGN
I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF
MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO
THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN
COMPLIANCE WITH THE CITY OF GRAPEVINE ORDINANCE REGULATING
Page 1/2
MYGOV.US 254O04223, 11/21/2025 at 2:37 PM Issued by: Courtney Cogbum
CP►MoEN�I
30,3395 2p,22,23,2�,29,363? otF PLK
�1105�2 RVVET
GZYPE �3�810,26�5238�4' cE4l.- oEN SaKm a
V - 12, 1 3 REao • N � v5
pRiME EVME MVb�-aaNY
GR��ER�aREa-
gUV�D GTYPE 2g,2B, FyEPP
g�\\\ o N� rYPE\v SEP`ED LE��ER
ev\r`e TX �6p51
s
N 3�1DTP�gU\�D\Nc' R trap P RED etoltA E
e Md\s \OttA
A ETE
D
W 3gp0 Grapev\De pV\DE sG EG STE SpECT��N
S GES REp 5 pR FROR1 1G s�N IN �S
cNPN L of REv` C0Nov AWNE
ppPvt p`PNg AppR
RoNjED P 1 E PT PPS MES OP GRFOR coppYR RK NO
pEV\NE UOt\pN
\ 0
EP ON Jags CT\OHS' iN\5SE�OE�SSE\ �EpRZON
K FpR \NSPE cONF�to�\� EEKEPt ONtHEJO
PCjpRSNpI 4��ZOO NW0. 6E PPPROVES�ptAl 5
CpNTR �$Al) T�M\j
j\DP\RPS`DN.
pG\S
ar
CpN1RPC3�
ON PEREX 5 g;04:53 P \ g9�
D KE�pY 1AFT (SgPE'
E�DKE OURS gY .
R ? ON H
DRUG \\
C�NO� pM• �vRpp,Y OS NpNX R0.E E MsORP BEPPPROVEO.
WO ppPERM\T (ED �N p CHANGE dUSt
N G,
SEPERp ( EEG R\ REQU\RED
MEGHR TS`SHP�`BE
S\GN pE
ESTATE
u.m
VISTA
Yn
nj RECYCLING \
GATES
CARPORT
{} TRASH
O PET STATIONS THROUGHOUT
nn VISITOR PARKING AVAILABLE
+emu'
NATLIRFTRAII
III
CATCNa A4Fh9E
Pww
PROVIDE SIGNED AND SEALED LETTER
FROM REGISTERED ENGINEER
CONFIRMING SITE INSPECTION AND
APPROVAL WHEN WORK IS COMPLETE
-r
L
r
I� ikL
L
CITY OF GRAPEVINE
THIS PAGE RELEASED FOR CONSTRUCTION
RELEASE DOES NOT AUTHORIZE ANY WORK IN
CONFLICT WITH THE BUILDING CODE ORZONING
NATURETRAIL IRDINANCE
CITY APPROVED PLANS TO BE KEPT ON THE JOB
SITE AT ALL TIMES.
11 /20/2025 8:07:51 AM
BY: KELLY TAFT TSBPE: 1-3971
BUILDING INSPECTION DIVISION:
RELEASE DOES NOT APPLY TO CONSTRUCTION IN
EASEMENTS OR PUBLIC RIGHT-OF-WAY
ALL CHANGES MUST BE APPROVED.
Construction Plan Building
13
At exterior balconies at Units on the building centers:
This includes the following units: 1334-80sgft,1324-80sgft, 1335-80sgft, 1325-80sgft,
1332-80sgft,1322-80sgft,1337-80sgft,1327-80sgft, 1333-80sgft, 1336-80sgft 1.
Remove existing concrete and waterproofing from the affected area, down to the wood
decking. If the area in question is positioned against the Unit wall, remove cladding
from the base of wall, at least 1 foot up from the balcony deck or higher if necessary, to
expose the balcony Flashing on the wall and a working edge of the WRB (do not remove
the WRB from this area, pull the bottom edge up while minimizing damage to the WRB
to allow access to the balcony waterproofing on the wall.) If the area in question is
positioned at the balcony edge
2. Survey the existing structural wood decking, trusses, and structural components of the
balcony deck upon removal of the existing concrete and waterproofing layers.
Report, in writing, any damaged areas of wood decking or sheathing to the Engineer. The
Engineer shall determine if, and to what extent, structural repair is necessary.
3. Once all necessary repairs to structural components are complete, install new
waterproofing membrane (Polyguard 650 Sheet Membrane) to the decking and install new
drainage mat (Polyflow BD) over the waterproofing membrane.
Reinstall all components previously removed including base flashing, metal drip edge,
termination bar, and guardrail anchors to match existing materials. At base of Unit wall
conditions, ensure the waterproofing membrane is turned up at least 6 inches onto the
sheathing and sealed at the leading edge to the sheathing. CITY OF GRAPEVINE
CONFLICT WHR THE BUILDING CODE OR ZONING
PROVIDE SIGNED AND SEALED LETTER CITY SITE PLANS
ALLL TIME S°,BNTHE JGB
FROM REGISTERED ENGINEER 11/20/2025808a6 AM
BY: KELLY TAFT TSBPE: 1-3971
CONFIRMING SITE INSPECTION AND
APPROVAL WHEN WORK IS COMPLETE RELEASE
EASEME„TSORPUBLIC„w„T°,wp. „
ALL CHANGES MB Si BE APPROVED.
4. Reinstall lightweight concrete on the balcony deck. At base of Unit wall conditions, install
galvanized metal "L" flashing at the base of wall, positioned to cover the concrete edge and
bedded in sealant to the concrete on the horizontal plane, and install flashing tape at the leading
edge of the metal flashing on the wall sealing it to the sheathing.
Overlay the existing WRB system over the flashing assembly at the base of wall and reinstall
the cladding to match the existing materials. Ensure a minimum 1/2" gap is maintained
between bottom of the cladding and the metal flashing to allow for drainage. Apply new
coatings to all affected surfaces to match existing coating.
At exterior balconies at Units on the building corners where parapet wing -walls are present:
This includes the following units: 1331-250sgft, 1321-250sgft, 1338-250sgft, 1328-250sgft
1. Remove wood trim board from the cap of the wing -wall. Remove siding/stucco and WRB
from both faces of the wing -wall (the side facing the balcony and the side facing the sloped roof).
Remove cladding from the elevation wall surrounding the intersection between the wing -wall
and the elevation wall (saddle condition) without removing, and minimizing damage to, the
existing WRB.
2. Survey the existing sheathing, wood studs, adjacent balcony deck, and adjacent roof
decking and trusses upon removal of the existing cladding and waterproofing layers. Report, in
writing, any damaged areas of wood decking or sheathing to the Engineer. The Engineer shall
determine if, and to what extent, structural repair is necessary.
3. Install new WRB (DuPont Tyvek) over the sheathing on both faces of the wing -wall, turned
over onto the existing WRB on the elevation wall and overlapped at least 6 inches. Install new
Flashing Tape (DuPont StraightFlash) over the wing -wall cap, wrapped over the WRB on the sides,
and turned up onto the sheathing at the elevation wall to form a "saddle' between the wing -wall
and the elevation wall. Sequence the existing WRB over the leading edge of the flashing tape at
the "saddle" condition.
4. Re -install cladding on both faces of the wing -wall to match existing materials. Install new
trim board over balcony wing -wall cap, consisting of either water-resistant treated wood or fiber
cement. Install new sealant (MasterSeal NP-1) to all joints in the cladding and joints between vJC wN
ZONING
dissimilar materials. Apply new coatings to cladding and trim boards, to match existing coatings.
PROVIDE SIGNED AND SEALED LETTER
FROM REGISTERED ENGINEER
CONFIRMING SITE INSPECTION AND
APPROVAL WHEN WORK IS COMPLETE
_- uN THE JOB
_a 2-LIN.0
11/20/2025 8:09.56 AM
BY: KELLY TAFT TSBPE. 1-3971
OULLIXYG INSPECTION REVISION.
RELEASE DOES NOT APPLY TO CONSTRUNON IN
EASEMENTS OR PUDI IC RIGM OFYNAY
ALL CHANGES MUST BE APPROVED.