HomeMy WebLinkAboutPLBG2023-001968ADDRESS 1807 Rolling Ridge Dr. Grapevine, TX 76051 LEGAL Shadow Glen Addition Ph 2a & 2b Blk 10 Lot 10 A10 S220 10 *05840015* PERMIT HOLDER Stephen Harris Berkeys (817) 481-5869 COLLABORATORS •Stephen Harris Berkeys (817) 481-5869 OWNERS •Current Owner Current Owner INSPECTIONS 3 1. TCEQ Backflow Certification Submit 2. Backflow Device Inspection 3. Plumbing Final INFORMATION FIELDS **APPLICANT NAME (Individual)stephen harris **APPLICANT PHONE NUMBER 8176548174 VALUATION 2300 Square Footage 1930 FEE TOTAL PAID DUE Plumbing Permit Fee {VALUE}$ 57.00 $ 57.00 $ 57.00 TOTALS $ 57.00 $ 57.00 $ 0.00 The granting of this permit does not presume to give authority to violate or cancel the provisions of City, State, or other local laws regulating construction or the performance of construction. All provisions, laws, and ordinances governing this type of work shall be complied with, whether specified or not and shall be enforced at any and all times. City of Grapevine PO Box 95104 Grapevine, Texas 76099 817) 410-3166 Plumbing Permit {VALUE} Project# 23-001968 Project Description: replace 1- double check backflow device in yard Issued on: 06/02/2023 at 5:22 PM MYGOV.US 23-001968, 06/02/2023 at 5:22 PM Issued by: Connie Cook Page 1/1 Texas Commission on Environmental Quality I &1ATJ..6,11XWXWM�11'T_V IV The fr4lowin.. form must be q9nn� leted for each assernbl, tested. A si:med and dated ori.inal must be submirced to the oublic water sw, lier for recondkeeJw, u,703e,s:_ NAMEOFPWS: Citv of Grapevine PWS TD#,. 2200013 WS MAILING ADDRESS: 501 Shady Brook PWS CONTACT PERSON: Backflow Coordinator ADDRE§§r6F, SERVICE: SFD/ 1807 Rolling,f?idge Dr Monica/ Berke's PU 682-216-7959 The backflow prevention assembly detailed below has been tested and maintained as required by commission regulations and is certified to be opjatinpr within acceotable ��arameters. TYPE OF BACKFLOW PREVENTION ASSEMBLY (BPA): ■ Reduced Pressure Principle (RPBA) Reduced Pressure Principle -Detector (RPBA-D) Type H 0 Double Check Valve (DCVA) Double Check -Detector (DCVA-D0 Pressure Vacuum Breaker (PVB) Spill -Resistant Pressure Vacuum Breaker (SVB) Manufacturer: ain: �-V'04�< Bypass:, Size: Main:; ass: Model Number: Main: Bypass: PA Location: 'r crcl Serial Number: Main: Bypass:' BPA Serves: 4 Reason for test: ' New X Existing 0 Replacement 0 OldModel/Serial#� Is the assembly installed in accordance with manufacturer recommendations and/or local codes? lkl"Yes 0 No Is the assembly installed on anon -potable water supply (auxiliary)? Yes Q1\0 TEST RESULT Type 11 Reduced Pressure, Principle Assembly (RPBA) Assembly PVB &Sate... ...kl M .. ..,m-.,,«..,.,....::..:..A»:.......»n��_�___�_.. VB PASS DCVA Relief Valve i; Bypass Check °1� Air Inlet Check Valve FAIL Ell! I` Check �heck*** Initial Test 1, Held at psid: Held all" psid :':Opened at Held at psid Opened at psid !)Held at ?Date,, !'psid ,Closed Tight Closed Tight Closed Tight 0 :'Did not open 0 1 psid Did not Time5 ;Leaked ,Did it fullyopen "1eaked J)Leaked El ;Leaked11 ��open (Yes ONO Repairs and IlMain:' PIFUsed** ro Bypass: 191 _After jHeld at psid `Held at psid Opened at �1 Held at psid &P—a—ir ',IClosed Tight :aClosedTight 'psid �dClosed Date: 4 'Tight El Time: 2' check: numeric readinu iui d f DCVA I or 1�� ` Differential pressure gauge used: Potable: Non -Potable: Ell (,Make„ 1/M.odel':­_ Midwest 845-5 SN: jj�P531 Date tested for accurac 1 Remarks. Opened at psid "Held at i psid Company Name- �.01 Accuracy Backflow Licensed Tester Name ar I ta ri 1- Cox (Print/T6;e Company Address: Licensed Tester Name (Signature): Po Box 6832 Mckinney, Tx 75071 Company Phone PAT License # BP0017066 972-699-7156 1 : License Expiration Date: 2-23-25 The above is certified to be true at the time of testing. TEST RECORDS MUST BE KEPT FOR AT LEAST THREE YEARS (30 TAC §290.46(B)l ** USE ONLY MANUFACTURER'S REPLACEME'_NT PARTS TCEQ-20700 (Revision 04-04-2019) Page 1 of 1