HomeMy WebLinkAboutPLIRR2024-003804ADDRESS
340 W Northwest Hwy.
Grapevine, TX 76051
LEGAL
Grapevine Business
Park Blk 1 Lot 2
PERMIT HOLDER
Christopher Mullen
Clean Scapes - Dallas
COLLABORATORS
•Christopher Mullen
Clean Scapes - Dallas
(469) 994-3820 Cell
OWNERS
•Sl Industrial Storage
Lp
TENANTS
•Chris Morrison
Elmer's Heating & Air
Conditioning
(325) 352-9971
INSPECTIONS 5
1. Letter of Compliance (Irrigation)
2. TCEQ Backflow Certification Submit
3. Backflow Device Inspection
4. Plumbing Customer Sevice Inspection
5. Plumbing Final
INFORMATION FIELDS
**APPLICANT NAME (Individual)Chris Mullen
**APPLICANT PHONE NUMBER 4699943820
VALUATION 8500
FINAL TCEQ REPORT [Office Use Only]SKM_C550i24102810430.pdf
FEE TOTAL PAID DUE
Plumbing Miscellaneous Fee $ 37.00 $ 37.00 $ 37.00
TOTALS $ 37.00 $ 37.00 $ 0.00
READ AND SIGN
I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF
MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO
THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN
COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING
CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT
DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR
ORDINANCE OF THE CITY OF GRAPEVINE.
I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH
ANY FEDERAL, STATE, AND / OR LOCAL LAW REGARDING ENERGY
CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE
LAWS, AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE
SUBMITTED TO THE CITY UPON REQUEST.
October 29, 2024
Signature Date
City of Grapevine
PO Box 95104
Grapevine, Texas 76099
817) 410-3166
Plumbing - Irrigation
Permit
Project # 24-003804
Project Description: Install Irrigation System for "Elmer's
Heating & Air Conditioning" ****REQUIRED LANDSCAPING
AND IRRIGATION PER CU24-28 MUST BE INSTALLED
PRIOR TO C/O APPROVAL*****
Issued on: 10/29/2024 at 12:15 PM
MYGOV.US 24-003804, 10/29/2024 at 12:15 PM Issued by: Connie Cook
Page 1/2
Texas Commission on Environmental Quality
'RiMIL71 0VEW-ilu
for reemvAveping
-V,'A- E 0 F Fi� City of QraMine
PNVS ID#: 2200013
WSMAILINNG ADDRESS: 50ook GraDev ne iTX 76051
PW S CONTACT PERSONBackflow Coordinator
ADDRESS OF SERVJ�'Cf� Cl-a!5,5Lc Tile& Pja "tt 340 W Northwest HWY Grapevine, TX 76051
The backflow prevention assembly detailed below has been tested and rivintainedas requireil by commission regulations
and is certified to be opqrattn—vvithin acceplAk Le p=meters.
TYPE OF BAONA.S.SE.NIBIY (8P.-k):
0 Reduced PressurePtiriciple (RPBA) 0 Reduced Pressure Prmciple-Detector(RP13A-D) Type It 0
10 Double Check Valve (DCVA) Double Check -Detector (DCVA-D) Type 110
Pressure Vacuum Breaker (PVB). E] Spill-Resimant Pressure Vacuum Breaker (SVO)
Manufacturer:
Main:Febco Bypass:
Size: I Main: I" Bypa,.,%:
Model Number.
Main: 850 Bypass:
HPA Location: t Front parkway, at meter, by monument sign
Serial Number.
MainHH14824 Bypass:
BPA Serves: Irriqation
Reason ftw test:
New 0 Existing 0 Replacement
0 Old Mociel/Scrial
Is Ttre assembly
installed in accordance with manufacturer recomniendt
ioris, anti/or Il Codes? 91 Yes 0 No
I'S t a'sejbl y
installed on a non- able water supply (auxiliary)? 0 Yes 0 No
TEST RESUIX
Type 11
Aeduced Pressure Principle Assembly
nubly PVB & SVB
PASS IN
DCVA
RelieValve ass Air Inlet Check Valve
-f BypCht ck
FAIL 0
1" Check d 2'd Check-*** 0
Initial Test
4 U -
Y,field at 1.5 psid' Ifeldal 1.9— psid Opened at
Yield at psid" o ned at psid ilield at
Date: 10-28-24
i: Closed Tight 0 Closed Tight P%id
po!"Tight 0 �Did mat open 'id
0
Tin-te.- 9.43 AM
Did not
Leaked Leaked
Did it fully (Ten I -caked
lualzed 0
open
al
p(Ycs D IN,, 0)
Repairs and
Main:
field at psid �Opem-d at
Test After field at psi Hld at psid bpencd at
g
psid J�Celosed
Reppir Closed Tight 0 ��Closed Tiht 0
D Tight
0 ate:
2W check: numeric reading re, iuired fin DCVA only
psid Held at
id
Differential pressure I i Non -Potable: 0
gauge used: Potable: El
SN: '108210899 Date tested for accurac I09-20-2024
Make/MWO: Midwest 845
Remarks: Permit #24-003804
Company Maine: A&AAGtiveBa ow Licensed Tester Name
Peintr 17�-�). Joshua Sh
Etimpany Addrcss� 1611 N 1H 35E., Suite 410 Licensed Tester Nariv- (Signature):
V
!Carrollton, TX 75006
Company Ph(wtc- #: 972-242-2229 BPAT License # BPOO13307
License Expiration Date: 09-13-25
The above Is certified to be true at the time of testing.
TEST RECORDS MUST BE KEPT FOR AT LEAST THREE YEARS 130 TAC §21X).46(B)l
V1* USE ;I.Y MANUFACTURER'S REPLACEMENT PARTS
TCEQ-20700 (Revision 04-04-2019) Page I of I
Clean
> 0ARM 20 1�
Mcm0randum for City 4 (hapevine
Ile: Pemb 24443804
340 W, Nortim est Hm y
GrapevinVUX 76051
'I hi% irrig'alim System has been InMAIM.1 ill acco rda lice with all applicable staK, and
L,ocal laws, ordimances, ruICS. 1VL!L11,'1(i0fM and onlers, I have tested the sysimn and
determined that it has been installed according w dw irvig�mof) plan wid Js pruperly
ate 1juled Ar the most efTicient application of Nvater m IN time,
Backilow le"I resuhs suhnAW by a FCFQ certified backfiow tesOng twee; subinded
to the city on forms prkwidcd by the city,
C hstoj-)hej� NJullen, 1.12727()
,;',
FW fnigaHon Manager
Clean Scapes
Irrigation -Flow , Radius
Quantity: Symbol Description Part Number : Pressure:
Sprinklers
4
Hunter MP2000 180' - PROS-04-PRS40-CV
MP21000 90-2100
40 psil .0.77 gpirn 119 ft
4
Hunter MP2000 360' - PROS-04-PRS30
MP2000 360*
40 Iasi 1.48 19ft
2 (n
Hunter MP2000 90'- PROS-04-PRS40-CV
MP200090-210'
40 ;)si 0.43 f.. prn 20 ft
6 0
'Hunter MSBN-1 OF
MSBN-10F
30 :)si 1 upm 0 ft
Meters/Pumps
1 M
5/8 inch meter
Water Source #1
Backflow Assemblies
1 0
Wilkins 375-11"
375 - I"
Meter Size
5/8 inch meter
Control Valves
Static Pressure
65 psi
1 0
1 8
Hunter ICZ-101-25
Hunter PGV-1 OOG-S
iCZ-101
PGV-1 OOG-S
Elevation
0 k
2 e
Hunter PGV-10OG-S
PGV-1O-0G-S
Irrigation Accessories
Service Line Information
1 (3
Hunter FREEZE-CLIK
'Hunter
FREEZE-cLIK
-66-0
Pipe Category
Type K Copper
1 A
1
XCH-600
S;,ears 1 White PVC - Socket
XCH --
2-0110
M
Pipe Size
Type K Copper 1'
Lateral Line Pipe
Length
5 ft
38 ft
SPX-FLEXIOO
SPX-FLEX-1 00
it
Velocy
fps
5
383 ft
Class 200 1"
Mainline Pipe
23 ft -----
Tvoe K - Cower 3/4"
0
Recommendations
13ft ......
-
Schedule 40 1"
®
Maximum Recommended Flow
12.12 gpm
Drip Tubing
Available Working Pressure
53.05 psi
294 ft
HunterdAPL-09-12-CV
HDL-09-12-CV
NOE
Description ...
1 Master Meter #222102373
T'tMeter
Static Pressure
65 psi
Service Line
0. 172 psi
Meter Loss
3.588 psi
Wainline Comp nents
I
-'Loss -
i aCkfl6W
14 psi
:-Master Va_Iv -e' Loss
1.892 psi
Filter Loss
0
'Zone _gpm
Mainline Loss
2.29 psi 7
Valve Loss
1.892 psl
Lateral Loss
0 psi, -
Fittings Loss
0.229 1r)sl
Elevation Loss
0 psi
Sprinkler Re - uirement
40 I?si
Total Design Pressure
64.065 psi
Residual Pressure
0.935 psi
Sprinkler Zone Data
Zone # Total Area Total Flow Precip to
1 3482.27 Sa/Ft 9.86 (im 0.27 in/hr
Drip Zone Data
Zone # Total Area Total to Precip Rate
294 &,:,j/Ft 263.7 gph 1.44 in/hr
"J11,115 j.1., wr. 3
1 2 3 11"
86J 6 4.39
GPM GPM GPM
3W�l
0 5 10 20
ill = 10'
DATE: till,
9/21/24
JOB NUMBER!
340 W. Northwest H%
DRAWN BY."
Christopher Mullen
CVECVED BY:
SCALE:
V = 10'
SHEET.
1 of 1