HomeMy WebLinkAboutPLIRR2024-003804ADDRESS 340 W Northwest Hwy. Grapevine, TX 76051 LEGAL Grapevine Business Park Blk 1 Lot 2 PERMIT HOLDER Christopher Mullen Clean Scapes - Dallas COLLABORATORS •Christopher Mullen Clean Scapes - Dallas (469) 994-3820 Cell OWNERS •Sl Industrial Storage Lp TENANTS •Chris Morrison Elmer's Heating & Air Conditioning (325) 352-9971 INSPECTIONS 5 1. Letter of Compliance (Irrigation) 2. TCEQ Backflow Certification Submit 3. Backflow Device Inspection 4. Plumbing Customer Sevice Inspection 5. Plumbing Final INFORMATION FIELDS **APPLICANT NAME (Individual)Chris Mullen **APPLICANT PHONE NUMBER 4699943820 VALUATION 8500 FINAL TCEQ REPORT [Office Use Only]SKM_C550i24102810430.pdf FEE TOTAL PAID DUE Plumbing Miscellaneous Fee $ 37.00 $ 37.00 $ 37.00 TOTALS $ 37.00 $ 37.00 $ 0.00 READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND / OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS, AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST. October 29, 2024 Signature Date City of Grapevine PO Box 95104 Grapevine, Texas 76099 817) 410-3166 Plumbing - Irrigation Permit Project # 24-003804 Project Description: Install Irrigation System for "Elmer's Heating & Air Conditioning" ****REQUIRED LANDSCAPING AND IRRIGATION PER CU24-28 MUST BE INSTALLED PRIOR TO C/O APPROVAL***** Issued on: 10/29/2024 at 12:15 PM MYGOV.US 24-003804, 10/29/2024 at 12:15 PM Issued by: Connie Cook Page 1/2 Texas Commission on Environmental Quality 'RiMIL71 0VEW-ilu for reemvAveping -V,'A- E 0 F Fi� City of QraMine PNVS ID#: 2200013 WSMAILINNG ADDRESS: 50ook GraDev ne iTX 76051 PW S CONTACT PERSONBackflow Coordinator ADDRESS OF SERVJ�'Cf� Cl-a!5,5Lc Tile& Pja "tt 340 W Northwest HWY Grapevine, TX 76051 The backflow prevention assembly detailed below has been tested and rivintainedas requireil by commission regulations and is certified to be opqrattn—vvithin acceplAk Le p=meters. TYPE OF BAONA.S.SE.NIBIY (8P.-k): 0 Reduced PressurePtiriciple (RPBA) 0 Reduced Pressure Prmciple-Detector(RP13A-D) Type It 0 10 Double Check Valve (DCVA) Double Check -Detector (DCVA-D) Type 110 Pressure Vacuum Breaker (PVB). E] Spill-Resimant Pressure Vacuum Breaker (SVO) Manufacturer: Main:Febco Bypass: Size: I Main: I" Bypa,.,%: Model Number. Main: 850 Bypass: HPA Location: t Front parkway, at meter, by monument sign Serial Number. MainHH14824 Bypass: BPA Serves: Irriqation Reason ftw test: New 0 Existing 0 Replacement 0 Old Mociel/Scrial Is Ttre assembly installed in accordance with manufacturer recomniendt ioris, anti/or Il Codes? 91 Yes 0 No I'S t a'sejbl y installed on a non- able water supply (auxiliary)? 0 Yes 0 No TEST RESUIX Type 11 Aeduced Pressure Principle Assembly nubly PVB & SVB PASS IN DCVA RelieValve ass Air Inlet Check Valve -f BypCht ck FAIL 0 1" Check d 2'd Check-*** 0 Initial Test 4 U - Y,field at 1.5 psid' Ifeldal 1.9— psid Opened at Yield at psid" o ned at psid ilield at Date: 10-28-24 i: Closed Tight 0 Closed Tight P%id po!"Tight 0 �Did mat open 'id 0 Tin-te.- 9.43 AM Did not Leaked Leaked Did it fully (Ten I -caked lualzed 0 open al p(Ycs D IN,, 0) Repairs and Main: field at psid �Opem-d at Test After field at psi Hld at psid bpencd at g psid J�Celosed Reppir Closed Tight 0 ��Closed Tiht 0 D Tight 0 ate: 2W check: numeric reading re, iuired fin DCVA only psid Held at id Differential pressure I i Non -Potable: 0 gauge used: Potable: El SN: '108210899 Date tested for accurac I09-20-2024 Make/MWO: Midwest 845 Remarks: Permit #24-003804 Company Maine: A&AAGtiveBa ow Licensed Tester Name Peintr 17�-�). Joshua Sh Etimpany Addrcss� 1611 N 1H 35E., Suite 410 Licensed Tester Nariv- (Signature): V !Carrollton, TX 75006 Company Ph(wtc- #: 972-242-2229 BPAT License # BPOO13307 License Expiration Date: 09-13-25 The above Is certified to be true at the time of testing. TEST RECORDS MUST BE KEPT FOR AT LEAST THREE YEARS 130 TAC §21X).46(B)l V1* USE ;I.Y MANUFACTURER'S REPLACEMENT PARTS TCEQ-20700 (Revision 04-04-2019) Page I of I Clean > 0ARM 20 1� Mcm0randum for City 4 (hapevine Ile: Pemb 24443804 340 W, Nortim est Hm y GrapevinVUX 76051 'I hi% irrig'alim System has been InMAIM.1 ill acco rda lice with all applicable staK, and L,ocal laws, ordimances, ruICS. 1VL!L11,'1(i0fM and onlers, I have tested the sysimn and determined that it has been installed according w dw irvig�mof) plan wid Js pruperly ate 1juled Ar the most efTicient application of Nvater m IN time, Backilow le"I resuhs suhnAW by a FCFQ certified backfiow tesOng twee; subinded to the city on forms prkwidcd by the city, C hstoj-)hej� NJullen, 1.12727() ,;', FW fnigaHon Manager Clean Scapes Irrigation -Flow , Radius Quantity: Symbol Description Part Number : Pressure: Sprinklers 4 Hunter MP2000 180' - PROS-04-PRS40-CV MP21000 90-2100 40 psil .0.77 gpirn 119 ft 4 Hunter MP2000 360' - PROS-04-PRS30 MP2000 360* 40 Iasi 1.48 19ft 2 (n Hunter MP2000 90'- PROS-04-PRS40-CV MP200090-210' 40 ;)si 0.43 f.. prn 20 ft 6 0 'Hunter MSBN-1 OF MSBN-10F 30 :)si 1 upm 0 ft Meters/Pumps 1 M 5/8 inch meter Water Source #1 Backflow Assemblies 1 0 Wilkins 375-11" 375 - I" Meter Size 5/8 inch meter Control Valves Static Pressure 65 psi 1 0 1 8 Hunter ICZ-101-25 Hunter PGV-1 OOG-S iCZ-101 PGV-1 OOG-S Elevation 0 k 2 e Hunter PGV-10OG-S PGV-1O-0G-S Irrigation Accessories Service Line Information 1 (3 Hunter FREEZE-CLIK 'Hunter FREEZE-cLIK -66-0 Pipe Category Type K Copper 1 A 1 XCH-600 S;,ears 1 White PVC - Socket XCH -- 2-0110 M Pipe Size Type K Copper 1' Lateral Line Pipe Length 5 ft 38 ft SPX-FLEXIOO SPX-FLEX-1 00 it Velocy fps 5 383 ft Class 200 1" Mainline Pipe 23 ft ----- Tvoe K - Cower 3/4" 0 Recommendations 13ft ...... - Schedule 40 1" ® Maximum Recommended Flow 12.12 gpm Drip Tubing Available Working Pressure 53.05 psi 294 ft HunterdAPL-09-12-CV HDL-09-12-CV NOE Description ... 1 Master Meter #222102373 T'tMeter Static Pressure 65 psi Service Line 0. 172 psi Meter Loss 3.588 psi Wainline Comp nents I -'Loss - i aCkfl6W 14 psi :-Master Va_Iv -e' Loss 1.892 psi Filter Loss 0 'Zone _gpm Mainline Loss 2.29 psi 7 Valve Loss 1.892 psl Lateral Loss 0 psi, - Fittings Loss 0.229 1r)sl Elevation Loss 0 psi Sprinkler Re - uirement 40 I?si Total Design Pressure 64.065 psi Residual Pressure 0.935 psi Sprinkler Zone Data Zone # Total Area Total Flow Precip to 1 3482.27 Sa/Ft 9.86 (im 0.27 in/hr Drip Zone Data Zone # Total Area Total to Precip Rate 294 &,:,j/Ft 263.7 gph 1.44 in/hr "J11,115 j.1., wr. 3 1 2 3 11" 86J 6 4.39 GPM GPM GPM 3W�l 0 5 10 20 ill = 10' DATE: till, 9/21/24 JOB NUMBER! 340 W. Northwest H% DRAWN BY." Christopher Mullen CVECVED BY: SCALE: V = 10' SHEET. 1 of 1 *t