Loading...
HomeMy WebLinkAboutCU2025-20TRINIT Y INDUS T R I E S ADDN 43795E TRINIT Y INDUS T R I E S ADDN 43795E 41867 GRAND Y S OF GRAP E V I N E 16025 TRINIT Y INDUS T R I E S ADDN 43795E 2.00 @ .8838 AC.8089 AC 3.6143 @ STATE HWY 114 NORTHWEST PKWY EAST .7284 AC 2.5985 @ C 1 1 A A 6 1 1 MU N I C I P A L W A Y CAPITOL ST TR 4A3G 1 1C2A 1B1 1A1 1 3A1A 4A 1R1 2 3 4 1 1C1 FIRST NATION A L BANK 13877 GRAPE V I N E OFFICE PROPE R T Y ONE AD D N 16072P HCP GR A P E V I N E CONDO 16608C 1 8R9R 1.1899 AC TR 1H S M A I N S T 13 12 11 10 4 5 7 6 5.1671 @ 1.7197 @ .88 @ HC R-7.5 CC PO Grapevine GIS CU25-20; McDonald's 101 East State Highway 114 0 90 180 270 360 Feet ² Date Prepared: 11/12/2025 This data has been compiled by the City of Grapevine IT/GIS department. Various official and unofficial sources were used to gather this information. Every effort was made to ensure the accuracy of this data, however, no guarantee is given or implied as to the accuracy of said data. SUBJECT PROPERTY CU25-20 – 1st Review Memo Email a PDF of the revised plans by October 20, 2025 at 12:00 p.m. to emarohnic@grapevinetexas.gov, atriplett@grapevinetexas.gov, and amosley@grapevintexas.gov. Verify that all text is legible on an 11”x 17” sheet. Do not reproduce final copies requested below prior to Planning Staff approval. PROJECT DESCRIPTION: CU25-20; submitted by Olsson Associates for property located at 101 East State Highway 114, platted as Block A, Lot 1, Trinity Industries Addition. This site was previously approved for a conditional use permit CU96-16 (Ord. 96-49) to allow a combination restaurant and convenience store with gasoline sales, car wash, and the possession, storage, retail sale and off premise consumption of alcoholic beverages (beer and wine only). This request is specifically to convert the existing single-lane drive-through to a double-lane drive-thru and modify traffic flow east of the existing building for the McDonald’s restaurant. The property is zoned “CC”, Commercial District and is owned by 7-Eleven Inc. PLANNING SERVICES All Sheets in Plan Set P.1. Title Block: Update all sheets in three sheet plan set to have the title block present in the lower, right-hand corner of the sheet per the conditional use permit check list. Current title block is only shown on page SP-1.The standard title block is provided below. As currently shown on page SP-1, th e title block is missing the following information: Abstract Number, City of Grapevine, Texas under the address, the size of the lot in acres and square feet, the zoning district and the date of preparation. This should be provided on all sheets in the lower-right hand corner. Example provided below. P.2. Approval/Signature Block: Relocate the standard approval/signature block above the standard title block on all sheets above the required title block in the lower, right-hand corner of each sheet in the plan set. P.3. Approval/Signature Block: Add the assigned case number within the standard approval/signature block, CU25-20 on all plan sheet s in the set. P.4. Approval/Signature Block: Correct the department name at the bottom of block from “Development Services Department” to “Planning Services Department” on all plan sheets in the set. CU25-20 OCTOBER 13, 2025 MCDONALD’S 101 EAST STATE HIGHWAY 114 BLOCK A, LOT 1A1, 1B1, 1C1, AND 1C2A, TRINITY INDUSTRIES (GPVNE) CU25-20 – 1st Review Memo P.5. The plan set submitted appears to only be a “focused site plan”. We need to see the linework and data for the entire lot, including linework and the existing driveway along E. State Highway 114. P.6. Purpose Statement: Add the following purpose statement near the title and approval/signature blocks to each sheet of the thre e-page plan set. “The purpose of this Conditional Use Permit is to is to convert the existing single-lane drive-through to a double-lane drive-thru and modify traffic flow east of the existing building for the existing McDonald’s restaurant.” P.7. If the lot with the proposed dual drive-through scope of construction results in the lot no longer meeting minimum pervious and impervious surface area requirements, then a special exception will be required by the Board of Zoning Adjustment (BZA). When action from the BZA is required, then there will need to be a first and second reading of the conditional use request at the joint Planning and Zoning Commission and City Council meeting with a BZA public hearing in between (three total meetings). Dimensional Control Site Plan and Landscape Plan – Sheet # SP-1 P.8. Title Block: Update sheet set to have the title block present i n the lower, right- hand corner of the sheet per the conditional use pe rmit check list. Current title block is only shown on page SP-1.The standard title block is provided below. As currently shown on page SP-1, the title block is missing the following information: Abstract Number, City of Grapevine, Texas under the address, the size of the lot in acres and square feet, the zoning district and t he date of preparation. This should be provided on all sheets in the lower-right hand corner. Example provided below. P.9. Title Block: Rename the name of the first plan sheet in the thr ee-page plan set as “Dimensional Control Site Plan and Landscape Plan.” P.10. Approval/Signature Block: Relocate the standard approval/signature block above the standard title block on the sheet above t he required title block in the lower, right-hand corner of the sheet in the plan s et. P.11. Approval/Signature Block: Add the assigned case number within the standard approval/signature block, CU25-20 on the plan sheet in the set. P.12. Approval/Signature Block: Correct the department name at the bottom of the block from “Development Services Department” to “Pl anning Services Department” on the plan sheet. P.13. The plan set submitted appears to only be a “focused site plan”. We need to see the linework and data for the entire lot, including linework and the existing driveway along E. State Highway 114. CU25-20 – 1st Review Memo P.14. Purpose Statement: Add the following purpose statement near the title and approval/signature blocks on the sheet. “The purpose of this Conditional Use Permit is to is to convert the existing single-lane drive-through to a double-lane drive-thru and modify traffic flow east of the existing building for the existing McDonald’s restaurant.” The plan set submitted appears to only be a “focused site plan”. We need to see the linework and data for the entire lot, including linework and the existing driveway along E. State Highway 114. P.15. Total impervious area of the lot has been exceeded. Section 25.F.4 of the City of Grapevine Zoning Ordinance requires a maximum of 80 % of impervious surface area. Landscaping has been removed from the east side of the building to accommodate the extended width of the double drive-through. Potential areas to reclaim for landscaping include the drive-through c ar wash facility on the property which appears to not be operable/in-use. P.16. Based on comment # P.15 above, if the lot with the proposed dual drive-through scope of construction results in the lot no longer meeting minimum pervious and impervious surface area requirements, then a special exception will be required by the Board of Zoning Adjustment (BZA). When action from the BZA is required, then there will need to be a first and second readying of the conditional use request at the joint Planning and Zoning Commission and City Council meeting with a BZA public hearing in between (three total meetings). P.17. Provide labels of species and size of all relocated trees and shrubs per Section 53.E.4 and 5 of the Landscape Ordinance, Section 53. P.18. While not part of this construction, there may be a n error on the site plan. There is a ramp on the south side of the building labeled as an ADA ramp which does not lead to a marked off area nor does the ramp appear to have the correct width or slope for an ADA ramp. It is most likely a ramp use d to load supplies into the building through the door immediately north of the ramp. P.19. As this will be processed as a Conditional Use, and not a Specific Use Permit, review the conditions under Section 48.F of the Zon ing Ordinance pertaining to the decision by the Planning and Zoning Commission and City Council in determining whether a conditional use may be granted. Be prepared when brought to the public hearing to a nswer any questions regarding these standards that the Commission or Council may ask. P.20. Landscape Plan Notes: Add the following standards landscape plan notes - 1. Shrubs shall be a minimum of two (2) feet in height when measured immediately after planting. Hedges, where installed, shall be planted and maintained to form a continuous, unbroken, solid, visual screen which will be three (3) feet high within one (1) year after time of planting. 2. All requirements of the City of Grapevine soil erosion control ordinance shall be met during the period of construction 3. Light fixtures excluding accent lighting of architectural building features and lighting of public art or public monuments shall be mounted no higher than the highest point of the primary structure on the property. In no case shall light poles be greater than 30 feet in height. CU25-20 – 1st Review Memo P.21. Drawing: Label the building use as Convenience Store with Restaurant with Drive- through over the building linework. P.22. Drawing: Show, label, and dimension the gas canopy, dimension from other buildings on the lot and from the nearest lot lines. P.23. Drawing: Label gross building area (square feet), building height (# of stories), and building height (in feet to tallest element of the building). P.24. Drawing: Show existing and proposed water utilities and associated easements. Dimension easement widths. Label line sizes. Show and label water meters and provide identification symbols. Show and label valves, Fire Department connections, fire hydrants, detector check vaults, and other associated structures. P.25. Drawing: Show existing and proposed sanitary sewer utilities and associated easements. Dimension easement widths. Label line sizes. Label cleanouts, manholes, and other associated structures. P.26. Drawing: Show existing and proposed storm sewer utilities and associated easements. Dimension easement widths. Label line sizes. Label culverts, inlets, junction boxes, and other associated structures. P.27. Drawing: Label dumpster enclosure screening height and material(s). P.28. Drawing: Show and label type and height of screening walls, retaining walls, headlight screens, and/or living screens. For living screens, state plant type, size, and spacing. P.29. Drawing: Show and label type and height of fences and gates P.30. Legend: Under Grass Landscape Area - Be specific, what type of ground cover is proposed or existing (e.g. species name). P.31. Sign Legend and Symbols: Indicate if these wayfinding and menu board signs exist or are proposed. If proposed, provide additional information including elevations of proposed signage. Floor Plan (for restaurants) – Sheet Not Provided P.32. Not provided as sheet within plan set. Are any interior floor plan revisions proposed? If yes, provide an updated floorplan with your revised plan set resubmittal. Elevations – Sheet Not Provided P.33. Not provided as sheet within plan set. Are any exterior elevations revisions proposed? If yes, provide updated elevations with your revised plan set resubmittal. Photometric Plan – Sheet Not Provided P.34. Not provided as sheet within plan set. Are any exterior overhead lighting revisions proposed? If yes, provide an updated photometric plan with your revised plan set resubmittal. NOTE: See Section 55. Performance Standards Reduce light levels at ground level of all property lines of the subject property to the following levels based on the zoning of the adjacent properties: · Single-family – 0.2 footcandles · Multi-family – 0.5 footcandles · Non-residential districts, streets – 3.0 footcandles CU25-20 – 1st Review Memo · Industrial districts – 5.0 footcandles Speaker Plan – Sheet Not Provided P.35. Not provided as sheet within plan set. Are any outdoor exterior speakers proposed to be added or removed beyond existing or proposed menu ordering boards/signs? If yes, provide an updated outdoor speaker plan with your revised plan set resubmittal. NOTE: See Section 55. Performance Standards P.36. Show and label all proposed outdoor speakers. Dimension distance from speakers to closest property line. If adjacent to residential, show direction of speaker face and add table depicting maximum sound level (dBA) and hours speakers will be operating. See above table for maximum permissible sound levels. PUBLIC WORKS Contact Paul Lee - Civil Engineer, Elizabeth Reynold EIT or Cristin Turner (Platting) – Civil Engineer at 817.410.3000 for the following comments: · Show entire limits of lot, including linework for curb line adjacent to SH 114 (show full extent of the lot). Show all line work. · Ensure vehicles don’t stack into right-of-way. · If plat doesn’t match site plan, an amended plat will be required. BUILDING SERVICES Contact Larry Gray – Building Services at 817.410.3163 or lgray@grapevinetexas.gov to discuss the following: · Show entire limits of lot, including linework for curb line adjacent to SH 114 (show full extent of the lot). Show all line work. FIRE MARSHALL Contact Sam Daniel - Fire Department at 817.410.4421 or sdaniel@grapevinetexas.gov for the following comments: · Confirm Fire Lane is a minimum 24 feet in width (appears to be the case in the plans). PARKS Contact Kathy Nelson – Capital Improvements Program Manager at 817.410.3394 or knelson@grapevinetexas.gov to discuss the following: · No comments. ____________________________________________________________________ CU25-20 – 1st Review Memo Email a PDF of the revised final plans by October 20, at 12:00 p.m. to emarohnic@grapevinetexas.gov, atriplett@grapevinetexas.gov, and amoseley@grapevinetexas.gov. Verify that all text is legible on an 11”x 17” sheet. Do not reproduce final copies requested below prior to Planning Staff approval. Please direct all questions to Erica Marohnic at (8l7) 410-3155 or Albert Triplett at (817) 410- 3151. 09/26/2025 SP-1 Verify this is a ADA Ramp. Angle and width looks all wrong. Looks like a load-in ramp. Was a tree removed here? Section 25.F.4 CC Zoning Requires a maximum of 80% of total lot area. The site needs to convert another 4,037.2 SF to be in compliance with zoning. Non-operational carwash and adjacent concrete could be converted to landscape area. Loss of foundation planting along the east side of the building can be made up in here with additional shrub beds and ornamental trees. Please provide labels of species and size of all relocated trees. and shrubs. Section 53.E.4 and 5. Remove this purpose statement in this location. Add the following purpose statement near the title and approval/signature blocks on the sheet. “The purpose of this Conditional Use Permit is to is to convert the existing single-lane drive-through to a double-lane drive-thru and modify traffic flow east of the existing building for the existing McDonald’s restaurant.” Landscape Plan Notes: Add the following standards landscape plan notes - 1. Shrubs shall be a minimum of two (2) feet in height when measured immediately after planting. Hedges, where installed, shall be planted and maintained to form a continuous, unbroken, solid, visual screen which will be three (3) feet high within one (1) year after time of planting. 2. All requirements of the City of Grapevine soil erosion control ordinance shall be met during the period of construction. 3. Light fixtures excluding accent lighting of architectural building features and lighting of public art or public monuments shall be mounted no higher than the highest point of the primary structure on the property. In no case shall light poles be greater than 30 feet in height. Label as a Convenience Store with Restaurant Indicate if these wayfinding and menu board signs exist or are proposed. If proposed, provide additional information including elevations of proposed signage. Label gross building area (square feet), building height (# of stories), and building height (in feet to tallest element of the building). CUP Be specific, what type of ground cover is proposed or existing (e.g. species name) Label dumpster enclosure screening height and material(s). Add case # CU25-20 Revise to read: Planning Services Department Update with missing information per comment letter. Relocate Title Block per comment letter. Relocate Approval/Signature Block per comment letter. SSMH-2 6" LTP 12" J 16" EM EM LTP 12" 16" SS G G G G EM EM FO FO FO FO FO FO FO FO FO FO FO DRIVE THROUGH WINDOW ADA WALKWAY ADA WALKWAY ADA WALKWAY N89° 34' 58.96"E 265.37 L =6 0.2 2,R =7 6 5.0 0 SINGLE-STORY RESTAURANT BRICK/STUCCO F.F.E. = 652.00' GRA S S GRA S S GR A S S GRASS GRA S S GR A S S GRASS CONTROL POINT # 100 65 1 651 64 9 65 1 65 0 64 9 651 650 651 6 5 1 652 SSMH-1 TRINITY INDUSTRIES ADDITION DOC. NO 068737-2009 CALLED 2.7772 ACRES, 120974 SQ. FT. LOT 1, BLOCK 1 AN ADDITION TO THE CITY OF GRAPEVINE, TEXAS O.P.R.T.C.T. DRIVE THRU WINDOW OUTER DRIVE THRU WINDOW OUTER DRIVE THRU WINDOW CENTER W W W W W W W W W W W W W W WW WWWWWW F L F L FL FL FL FL FL FL F L F L FL FL FL FL FL FL 35°0'0"'25°0'0"' 50°0'0"' 35°0'0"' 8.5' 8' 14' 15' 5.75' 1.50' 5.75' 15.00' 1.50' R1.50' R20' 1.25' 1.25' R3' R10' R30' R10'R10' R10'R10' R20' R30' 22.24' 15.88' 14' 2.00' 58.29' 5' 20' 6.59' 10' 18' 24'19.34' 10' 4' POINT TABLE POINT # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 NORTHING 7022287.7149 7022261.3563 7022261.5130 7022254.8333 7022254.8197 7022229.6710 7022229.4290 7022221.8294 7022288.3162 7022268.6738 7022201.5649 7022191.4390 7022209.6529 7022209.7596 7022199.1723 7022235.1561 7022246.0150 7022245.1472 7022235.3341 7022249.3566 7022282.8743 7022298.3153 7022194.7523 7022206.7067 7022240.8354 7022246.6040 7022242.5764 7022294.2689 7022282.6764 7022237.0052 7022231.4003 7022217.3865 7022209.7062 7022217.9345 7022232.9454 7022238.4257 7022194.1731 7022194.4045 7022265.9732 7022262.0915 7022261.9403 7022298.2642 7022193.7471 7022193.7987 EASTING 2404958.2493 2404958.5158 2404974.0150 2404974.0825 2404972.7426 2404972.9968 2404949.0581 2404949.1349 2404957.7124 2404977.9699 2404979.1644 2404970.1856 2404991.0223 2404997.0214 2404994.2094 2404996.5693 2404993.1323 2404990.3906 2405006.5678 2405002.8044 2404984.2049 2404957.5821 2404976.6481 2404994.0752 2404995.6402 2404991.4377 2405005.5472 2404973.0245 2404971.8955 2404975.3495 2404976.6330 2404975.9828 2404994.0219 2404994.1304 2404994.6084 2404992.8681 2404994.2983 2405007.2963 2404993.5836 2404986.5884 2404978.0898 2404953.6542 2404988.6389 2405000.2513 FULL DESCRIPTION COB COB COB COB COB COB COB COB EOR EOR EOR EOR EOR/EOS EOR/EOS EOR EOR EOR EOR EOR EOR EOR EOR COR COR COR COR COR COR COR COF COF COF COF COF COF COF EOS EOS EOS EOS EOS EOS EOS EOS DA T E Mc D o n a l d ' s U S A , L L C RE V DE S C R I P T I O N BY ww w . o l s s o n . c o m TE X A S R E G I S T E R E D 57 0 0 T E N N Y S O N P A R K W A Y SU I T E 1 0 0 PL A N O , T X 7 5 0 2 4 TE L 2 1 4 . 4 7 3 . 2 7 1 3 EN G I N E E R I N G F I R M F - 4 2 5 3 DR I V E T R U L A Y O U T SP.2 LAYOUT NOTE NORTHING-EASTING LOCATION GIVEN AT BACK OF CURB. DIMENSIONS ARE GIVEN AT FACE OF CURB. COB - CORNER OF BUILDING FOUNDATION EOR - END OF RADIUS COR - CENTER OF RADIUS COF - CENTER OF FOUNDATION EOS - END OF STRIPING ALL PAVEMENT DIMENSIONS ARE TO FACE OF CURB, OR EDGE OF PAVEMENT WHERE NO CURB IS PRESENT, UNLESS OTHERWISE NOTED. DIMENSIONED TIES BETWEEN PROPERTY LINES AND BUILDING FACES OR PAVEMENT ARE AS INDICATED. THE CONTRACTOR IS RESPONSIBLE FOR MAKING ANY ADJUSTMENTS NECESSARY FOR FOUNDATIONS, BEDDING EXTENSIONS, SURCHARGING, ETC. NOTES 10'20'5'0' SCALE IN FEET 09/26/2025 SP-2 F L F L FL FL FL FL FL FL F L FL FL FL FL FL FL FL SSMH-2 6" LTP 12" J 16" EM EM LTP 12" 16" SS G G G G EM EM FO FO FO FO FO FO FO FO FO FO FO DRIVE THROUGH WINDOW ADA RAMP ADA WALKWAY N89° 34' 58.96"E 265.37 L =6 0.2 2,R =7 6 5 .0 0 S 4 2 ° 5 5 ' 5 8 . 0 4 " E SSMH-1 W W W W W W W WWW FFE = 652.00 TC/ME=651.98 TC=651.80 TC=651.20 TC=651.12 TC=651.00 TC/ME=650.99 TC=650.55TC=650.79 TC=650.90 TC=651.26 TC=651.15 TP/ME=649.43TP/ME=650.49 TP/ME=651.21 TP/ME=648.94 TP/ME=648.81 TC/ME=648.53 TC=648.75 TC=649.49 TP/ME=650.06 TC/ME=649.31 TS/TC=650.94 TS/TC=651.11 TP/ME=648.37 65 1 65 0 64 9 649 64 9 65 0 65 1 65 0 64 9 65 1 TP/ME=649.37 TP/ME=648.13 TC/ME=649.38 65 1 65 0 6 4 9 64 8 65 0 64 9 650 65 0 6 4 9 6 4 7 648 651 650 652 652 651 65 1 651 1.2 7 % 4.8 6 % 3. 9 1 % 1. 2 8 % 4.01 % 4.32% 1. 5 0 % 3 . 4 0 % 4.3 2 % 3.46% TS=650.61 TS=650.51 TC (HP)=649.74 7. 7 2 % DA T E Mc D o n a l d ' s U S A , L L C RE V DE S C R I P T I O N BY ww w . o l s s o n . c o m TE X A S R E G I S T E R E D 57 0 0 T E N N Y S O N P A R K W A Y SU I T E 1 0 0 PL A N O , T X 7 5 0 2 4 TE L 2 1 4 . 4 7 3 . 2 7 1 3 EN G I N E E R I N G F I R M F - 4 2 5 3 GR A D I N G P L A N C5.0 CONSTRUCTION: 1.THE CONTRACTOR SHALL INSTALL TRAFFIC CONTROL WHILE WORKING IN THE PUBLIC RIGHT-OF-WAY AS SHOWN IN THESE PLANS. IF PLANS ARE NOT PROVIDED, CONTRACTOR SHALL COORDINATE AND PROVIDE CONTROLS TO THE SATISFACTION OF THE RIGHT-OF-WAY OWNER 2.THE CONTRACTOR SHALL PROTECT ALL TREES OVER 3" CALIPER FROM DAMAGE. NO TREE SHALL BE REMOVED WITHOUT PERMISSION OF THE OWNER, UNLESS SHOWN OTHERWISE ON THESE PLANS. 3.AS A MINIMUM THE CONTRACTOR SHALL PERFORM THE GRADING AS FOLLOWS: 3.1.THE CONSTRUCTION AREA SHALL BE CLEARED, GRUBBED, AND STRIPPED OF TOPSOIL AND ORGANIC MATTER FROM ALL AREAS TO BE OCCUPIED BY BUILDING AND PAVING. STRIPPING EXISTING TOPSOIL AND ORGANIC MATTER SHALL BE TO A MINIMUM DEPTH OF 6 INCHES. TOPSOIL FOR REPLACEMENT ON SLOPES MAY BE STOCKPILED ON SITE IN AREAS DESIGNATED BY THE OWNER. CONTRACTOR SHALL REMOVE EXCESS STRIPPINGS AND EXCESS EXCAVATION WITHIN 30 DAYS OF COMPLETION OF GRADING OPERATIONS. 3.2.AREAS TO RECEIVE FILL AND AREAS CUT TO SUBGRADE LEVEL SHALL BE SCARIFIED AND THE TOP 8-INCH DEPTH COMPACTED TO 95% STANDARD PROCTOR DENSITY. THE SUBGRADE SHALL BE PROOF ROLLED WITH A MODERATELY HEAVY LOADED DUMP TRUCK OR SIMILAR APPROVED CONSTRUCTION EQUIPMENT TO DETECT UNSUITABLE SOIL CONDITIONS. ANY UNSUITABLE AREAS SHALL BE UNDERCUT AND REPLACED WITH SUITABLE MATERIAL BEFORE AN FILL MATERIAL CAN BE APPLIED. 3.3.FILL SHALL BE PLACED IN MAXIMUM OF 8 INCH LIFTS. 3.4.TOPSOIL SHALL BE PLACED TO A MINIMUM DEPTH OF 6 INCHES OVER ALL AREAS DISTURBED BY THE WORK. LARGE STONES, STICKS AND LUMPS SHALL BE REMOVED OR BROKEN UP, AND THE TOPSOIL SHALL BE LEVELED AND RAKED. ALL DISTURBED AREAS SHALL BE LANDSCAPED PER LANDSCAPE PLANS OR SHALL BE SEEDED, FERTILIZED, MULCHED, WATERED AND MAINTAINED UNTIL HARDY GRASS GROWTH IS ESTABLISHED. 3.5.CONTRACTOR SHALL PROVIDE COMPACTION TEST RESULTS AS REQUIRED. 4.THE CONTRACTOR SHALL DISPOSE ALL WASTE MATERIAL RESULTING FROM THE PROJECT OFF-SITE AND IN STRICT CONFORMANCE WITH ALL LOCAL CODES AND ORDINANCES. 5.ALL MANHOLES, CATCH BASINS, UTILITY VALVES AND METER PITS ARE TO BE ADJUSTED OR REBUILT TO GRADE AS REQUIRED, NOT ALL ADJUSTMENTS ARE INDICATED IN THE PLANS. 6.THE CONTRACTOR SHALL STREET SWEEP OR OTHERWISE CLEAN ALL ACCESS ROUTES TO THE SITE AT CONCLUSION OF THE PROJECT. 7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONTROL OF DUST AND DIRT RISING AND SCATTERING IN THE AIR DURING CONSTRUCTION AND SHALL PROVIDE WATER SPRINKLING OR OTHER SUITABLE METHODS OF CONTROL. 8.THE EXISTING AND PROPOSED FINISHED GROUND SURFACES ARE AVAILABLE ELECTRONICALLY FOR CONTRACTOR VERIFICATION VIA E-MAIL (IN AUTOCAD FORMAT). THE CONTRACT SHALL BE RESPONSIBLE FOR FIELD VERIFYING THE EXITING GROUND SURFACE ELEVATIONS. GRADING PLAN NOTES: 1.THE CONTOUR LINES, SPOT ELEVATIONS AND BUILDING FLOOR ELEVATIONS SHOWN ARE TO FINISH GRADE, SURFACE OF PAVEMENT, TOP OF CURBS, ETC. REFER TO TYPICAL SECTIONS FOR PAVING, SLAB AND AGGREGATE BASE THICKNESS TO DEDUCT PAVEMENT DEPTH FROM ELEVATIONS SHOWN. 2.THE CONTRACTOR SHALL FINISH GRADE SLOPES AS SHOWN NO STEEPER THAN 1 FOOT VERTICAL IN 3 FEET HORIZONTAL. 3.THE CONTRACTOR SHALL GRADE LANDSCAPED AREAS TO PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING AND SIDEWALKS WHEN FINISH LANDSCAPE MATERIALS ARE IN PLACE. 4.SPOT ELEVATIONS ARE TO EDGE OF PAVEMENT, BACK OF CURB, OR FINISHED GRADE UNLESS OTHERWISE INDICATED. (SEE LEGEND) 5.ACCESSIBLE PARKING STALL SHALL NOT EXCEED 2.00 PERCENT IN ANY DIRECTION. ACCESSIBLE SIDEWALKS HAVE A MAXIMUM CROSS SLOPE OF 2 PERCENT AND A MAXIMUM LONGITUDINAL SLOPE OF 5 PERCENT. SPOT ELEVATION LEGEND TC TOP OF CURB TP TOP OF PAVEMENT TS TOP OF SIDEWALK ME MATCH EXISTING LEGEND PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR 20'40'10'0' SCALE IN FEET 09/26/2025 GR-1 CU25-20 – 2nd Review Memo Email a PDF of the revised plans by October 29, 2025, at 12:00 p.m. to emarohnic@grapevinetexas.gov, atriplett@grapevinetexas.gov, and amosley@grapevintexas.gov. Verify that all text is legible on an 11”x 17” sheet. Do not reproduce final copies requested below prior to Planning Staff approval. PROJECT DESCRIPTION: CU25-20; submitted by Olsson Associates for property located at 101 East State Highway 114, platted as Block A, Lot 1, Trinity Industries Addition. This site was previously approved for a conditional use permit CU96-16 (Ord. 96-49) to allow a combination restaurant and convenience store with gasoline sales, car wash, and the possession, storage, retail sale and off premise consumption of alcoholic beverages (beer and wine only). This request is specifically to convert the existing single-lane drive-through to a double-lane drive-through and modify traffic flow east of the existing building for the McDonald’s restaurant. The property is zoned “CC”, Commercial District and is owned by 7-Eleven Inc. PLANNING SERVICES All Sheets in Plan Set NEW COMMENT S ON SHEET NAMES: • Rename Sheet SP -1 within the Title Block: Site and Landscape Plan • Rename Sheet SP -2 within the Title Block: Focused Site Plan Or Stacking Exhibit • Rename Sheet SP -3 within the Title Block: Grading Plan • Rename Sheet SP -4 within the Title Block: Details or Detail 1 • Rename Sheet SP -5 within the Title Block: Details or Detail 2 P.1. ADDRESSED. Title Block: Update all sheets in three sheet plan set to have the title block present in the lower, right -hand corner of the sheet per the conditional use permit check list. Current title block is only shown on page SP -1.The standard title block is provided below. As currently shown on page SP -1 , the title block is missing the following information: Abstract Number, City of Grapevine, Texas under the address , the size of the lot in acres and square feet, the zoning district and the date of preparation. This should be p rovided on all sheets in the lower - right hand corner . Example provided below. CU25-20 OCTOBER 27, 2025 MCDONALD’S 101 EAST STATE HIGHWAY 114 BLOCK A, LOT 1A1, 1B1, 1C1, AND 1C2A, TRINITY INDUSTRIES (GPVNE) CU25-20 – 2nd Review Memo P.2. ADDRESSED. Approval/Signature Block: Relocate the standard approval/signature block above the standard title block on all sheets above the required title block in the lower, right -hand corner of each sheet in the plan set. P.3. ADDRESSED. Approval/Signature Block: Add the assigned case number within the standard approval/signature block, CU25 -20 on all plan sheets in the set . P.4. ADDRESSED. Approval/Signature Block: Correct the department name at the bottom of block from “Development Services Department” to “Planning Services Department” on all plan sheets in the set . P.5. PARTIALLY ADDRESSED. The plan set submitted appears to only be a “focused site plan”. We need to see the linework and data for the entire lot, including linework and the existing driveway along E. State Highway 114. P.6. ADDRESSED. Purpose Statement: Add the following purpose statement near the title and approval/signature blocks to each sheet of the three -page plan set. “The purpose of this Conditional Use Permit is to is to convert the existing single-lane drive- through to a double-lane drive-thru and modify traffic flow east of the existing building for the existing McDonald’s restaurant.” P.7. PARTIALLY ADDRESSED. Revision needs to show the whole lot which goes northward, on the other side of Capitol Street. Refer to email attachments sent 10/21/2025 (plat and screenshot). If the lot with the proposed dual drive-through scope of construction results in the lot no longer meeting minimum pervious and impervious surface area requirements, then a special exception will be required by the Board of Zoning Adjustment (BZA). When action from the BZA is required, then there will need to be a first and second reading of the conditional use request at the joint Planning and Zoning Commission and City Council meeting with a BZA public hearing in between (three total meetings). Dimensional Control Site Plan and Landscape Plan – Sheet # SP-1 P.8. PARTIALLY ADDRESSED. If this sheet acts as a combination site plan/ landscape plan it needs to say Site plan AND Landscape Plan in the title block (SP-1). Title Block: Update sheet set to have the title block present in the lower, right -hand corner of the sheet per the conditional use permit check list. Current title block is only shown on page SP -1.The standard title block is provided below. As currently shown on page S P -1, the title block is missing the following information: Abstract Number, City of Grapevine, Texas under the address, the size of t he lot in acres and square feet, the zoning district and the date of preparation. This should be provided on all sheets in the lower -right hand corner . Example provided below. CU25-20 – 2nd Review Memo P.9. NOT ADDRESSED. See Comment P8. above. Title Block: Rename the name of the first plan sheet in the three -page plan set as “Dimensional Control Site Plan and Landscape Plan.” P.10. ADDRESSED. Approval/Signature Block: Relocate the standard approval/signature block above the standard title block on the sheet above the required title block in the lower, right -hand corner of the sheet in the plan set. P.11. ADDRESSED. Approval/Signature Block: Add the assigned case number within the standard approval/signature block, CU25 -20 on the plan sheet in the set. P.12. ADDRESSED. Approval/Signature Block: Correct the department name at the bottom of the block from “Development Services Department” to “Planning Services Department” on the plan sheet. P.13. PARTIALLY ADDRESSED. Revision needs to show the whole lot which goes northward , on the other side of Capitol Street. Refer to email attachments sent 10/21/2025 (plat and screenshot). The plan set submitted appears to only be a “focused site plan”. We need to see the linework and data for the entire lot, including linework and the existing driveway along E. State Highway 114. P.14. ADDRESSED. Purpose Statement: Add the following purpose statement near the title and approval/signature blocks on the sheet. “The purpose of this Conditional Use Permit is to is to convert the existing single-lane drive-through to a double-lane drive- thru and modify traffic flow east of the existing building for the existing McDonald’s restaurant.” P.15. PARTIALLY ADDRESSED. Revision needs to show the whole lot which goes northward, on the other side of Capitol Street. Refer to email attachments sent 10/21/2025 (plat and screenshot). Total impervious area of the lot has been exceeded. Section 25.F.4 of the City of Grapevine Zoning Ordinance requires a maximum of 80% of impervious surface area. Landscaping has been removed from the east side of the building to accommodate the extended w idth of the double drive -through. Potential areas to reclaim for landscaping include the drive -through car wash facility on the property which appears to not be operable/in -use . P.16. PARTIALLY ADDRESSED. Revision needs to show the whole lot which goes northward, on the other side of Capitol Street. Refer to email attachments sent 10/21/2025 (plat and screenshot). Based on comment # P.15 above, if the lot with the proposed dual drive- through scope of construction results in the lot no longer meeting minimum pervious and impervious surface area requirements, then a special exception will be required by the Board of Zoning Adjustment (BZA). When action from the BZA is required, then there will need to be a first and second readying of the conditional use request at the joint Planning and Zoning Commission and City Council meeting with a BZA public hearing in between (three total meetings). P.17. ADDRESSED. Provide labels of species and size of all relocated trees and shrubs per Section 53.E.4 and 5 of the Landscape Ordinance, Section 53. P.18. ADDRESSED. While not part of this construction, there may be an error on the site plan. There is a ramp on the south side of the building labeled as an ADA ramp which does not lead to a marked off area, nor does the ramp appear to have the CU25-20 – 2nd Review Memo correct width or slope for an ADA ramp. It is most likely a ramp used to load supplies into the building through the door immediately north of the ramp. P.19. FYI. As this will be processed as a Conditional Use, and not a Specific Use Permit, review the conditions under Section 48.F of the Zoning Ordinance pertaining to the decision by the Planning and Zoning Commission and City Council in determining whether a condi tional use may be granted. Be prepared when brought to the public hearing to answer any questions regarding these standards that the Commission or Council may ask. P.20. ADDRESSED. Landscape Plan Notes: Add the following standards landscape plan notes - 1. Shrubs shall be a minimum of two (2) feet in height when measured immediately after planting. Hedges, where installed, shall be planted and maintained to form a continuous, unbroken, solid, visual screen which will be three (3) feet high within one (1) year after time of planting. 2. All requirements of the City of Grapevine soil erosion control ordinance shall be met during the period of construction 3. Light fixtures excluding accent lighting of architectural building features and lighting of public art or public monuments shall be mounted no higher than the highest point of the primary structure on the property. In no case shall light poles be greater than 30 feet in height. P.21. ADDRESSED. Drawing: Label the building use as Convenience Store with Restaurant with Drive-through over the building linework. P.22. ADDRESSED. Drawing: Show, label, and dimension the gas canopy, dimension from other buildings on the lot and from the nearest lot lines. P.23. ADDRESSED. Drawing: Label gross building area (square feet), building height (# of stories), and building height (in feet to tallest element of the building). P.24. ADDRESSED. Drawing: Show existing and proposed water utilities and associated easements. Dimension easement widths. Label line sizes. Show and label water meters and provide identification symbols. Show and label valves, Fire Department connections, fire hydrants, detector check vaults, and other associated structures. P.25. ADDRESSED. Drawing: Show existing and proposed sanitary sewer utilities and associated easements. Dimension easement widths. Label line sizes. Label cleanouts, manholes, and other associated structures. P.26. ADDRESSED. Drawing: Show existing and proposed storm sewer utilities and associated easements. Dimension easement widths. Label line sizes. Label culverts, inlets, junction boxes, and other associated structures. P.27. ADDRESSED. Drawing: Label dumpster enclosure screening height and material(s). P.28. Drawing: Show and label type and height of screening walls, retaining walls, headlight screens, and/or living screens. For living screens, state plant type, size, and spacing. P.29. ADDRESSED. Drawing: Show and label type and height of fences and gates P.30. ADDRESSED. Legend: Under Grass Landscape Area - Be specific, what type of ground cover is proposed or existing (e.g. species name). P.31. ADDRESSED. Sign Legend and Symbols: Indicate if these wayfinding and menu board signs exist or are proposed. If proposed, provide additional information including elevations of proposed signage. CU25-20 – 2nd Review Memo Floor Plan (for restaurants) – Sheet Not Provided P.32. ADDRESSED. Not provided as sheet within plan set. Are any interior floor plan revisions proposed? If yes, provide an updated floorplan with your revised plan set resubmittal. Elevations – Sheet Not Provided P.33. ADDRESSED. Not provided as sheet within plan set. Are any exterior elevations revisions proposed? If yes, provide updated elevations with your revised plan set resubmittal. Photometric Plan – Sheet Not Provided P.34. ADDRESSED. Not provided as sheet within plan set. Are any exterior overhead lighting revisions proposed? If yes, provide an updated photometric plan with your revised plan set resubmittal. NOTE: See Section 55. Performance Standards Reduce light levels at ground level of all property lines of the subject property to the following levels based on the zoning of the adjacent properties: • Single-family – 0.2 footcandles • Multi-family – 0.5 footcandles • Non-residential districts, streets – 3.0 footcandles • Industrial districts – 5.0 footcandles Speaker Plan – Sheet Not Provided P.35. ADDRESSED. Not provided as sheet within plan set. Are any outdoor exterior speakers proposed to be added or removed beyond existing or proposed menu ordering boards/signs? If yes, provide an updated outdoor speaker plan with your revised plan set resubmittal. NOTE: See Section 55. Performance Standards P.36. ADDRESSED. Show and label all proposed outdoor speakers. Dimension distance from speakers to closest property line. If adjacent to residential, show direction of speaker face and add table depicting maximum sound level (dBA) and hours speakers will be operating. See above table for maximum permissible sound levels. PUBLIC WORKS Contact Paul Lee - Civil Engineer, Elizabeth Reynold EIT or Cristin Turner (Platting) – Civil Engineer at 817.410.3000 for the following comments: • PARTIALLY ADDRESSED. Revision needs to show the whole lot which goes northward, on the other side of Capitol Street. Refer to email attachments sent 10/21/2025 (plat and Agenda item # III. A. CU25-20.4sprc 1 TO: SITE PLAN REVIEW COMMITTEE MEMBERS FROM: ALBERT L. TRIPLETT JR., PLANNER II DATE: DECEMBER 3, 2025 SUBJECT: CONDITIONAL USE REQUEST CU25-20; MCDONALD’S, E. 101 STATE HIGHWAY 114 RECOMMENDATION Staff recommends the Site Plan Review Committee (SPRC) consider amendments to conditional use permit CU96-16 (Ord. 96-49) to allow a combination restaurant and convenience store with gasoline sales, car wash, and the possession, storage, retail sale and off premise consumption of alcoholic beverages (beer and wine only). This request is specifically to convert the existing single-lane drive-through to a dual-lane drive-through and modify traffic flow east of the existing building for the McDonald’s restaurant. The property is zoned “CC”, Community Commercial District and is platted as Block A, Lot 1, Trinity Industries Addition. REQUEST The proposed changes at existing McDonald’s restaurant are to convert the existing single drive-through into a dual drive-through and adjust the traffic flow east of the current building to improve circulation and reduce on-site congestion. These modifications are coordinated with the combination convenience store building and to ensure safe and efficient access for all customers on the lot. BACKGROUND INFORMATION The subject property was zoned both “C-2”, Community Business District and “S-P”, Site Plan District prior to the 1984 City-wide Rezoning at which time the subject site was rezoned to both “PO”, Professional Office District and “CC”, Community Commercial District. • On July 16, 1996, Council approved Conditional Use Request CU96- 16 (Ord. 96- 46) on the subject site to allow the possession, storage, retail sale and off premise consumption of alcoholic beverages (beer and wine only) gasoline sales and a drive through car wash in conjunction with a convenience store with a drive through restaurant. • On September 17, 1996, Council approved Conditional Use Request CU96-27 (Ord. 96- 80) an amendment to the subject site to allow for a 40-foot pole sign containing 288 square feet. Agenda item # III. A. CU25-20.4sprc 2 • On March 18, 1997, Council approved Conditional Use Request CU97- 09 (Ord. 97- 26) for revisions to the site plan, floor plan, exterior building elevations and landscape plan. • On May 2, 2012, the Site Plan Review Committee (SPRC) approved Conditional Use Request CU12-12 to allow for expanding the drive-lane for the McDonald's restaurant from a single to a dual-lane drive-through. The proposal was never constructed. • On July 12, 2017, the SPRC approved Conditional Use Request CU17-17 to allow exterior elevation changes, a minor floor plan change and a drive-lane modification to the McDonald’s restaurant. /em Planning Services The City of Grapevine P.O. Box 95104 Grapevine, Texas 76099 (817) 410-3155 https://bit.ly/GrapevinePlanning December 4, 2025 Olsson ATTN: Madeline Knecht 5700 Tennyson Parkway, Suite 100 Plano, TX 75024 Re: GRAPEVINE FILE # CU25-20 [McDonald’s ] To Whom It May Concern, This letter is to verify that your request for a conditional use permit located at E. 101 State Highway 114, platted as Block A, Lot 1, Trinity Industries Addition, to convert the existing single-lane drive-through to a double-lane drive-through and modify traffic flow east of the existing building for the McDonald’s restaurant was approved by the Site Plan Review Committee on December 3, 2025. A copy of the approved site plan is enclosed. Any changes to a site plan or elevations approved with a conditional use or a special use (no matter how minor or major) can only be approved by city council through the public hearing process. No Conditional Use Permit shall be valid for a period longer than one (1) year from the date on which the City Council grants the Conditional Use, unless within such one (1) year period: (1) a Building Permit is obtained and the erection or alteration of a structure is started, or (2) an Occupancy Permit is obtained and a use commenced. The City Council may grant one additional extension not exceeding one (1) year, upon written application, without notice or hearing. No additional extension shall be granted without complying with the notice and hearing requirements for an initial application for a Conditional Use Permit. Your next milestones in the development review process are to obtain civil construction drawing approval from Public Works and Building Permit approval with the Building Services Department. For questions related to this process, please reach out to the following individuals to coordinate: · Public Works – Paul Lee at (817) 410-3144 or plee@grapevinetexas.gov Planning Services The City of Grapevine P.O. Box 95104 Grapevine, Texas 76099 (817) 410-3155 https://bit.ly/GrapevinePlanning · Building Permits – Larry Gray at (817) 410-3163 or lgray@grapevinetexas.gov Building Permit applications are accepted at any point in the development review process but will not be released until any associated zoning cases or site plans are approved, civil engineering plans are approved, and any required plats are approved and filed. Please do not hesitate to contact us if we may be of further assistance (817) 410-3155. Sincerely, Erica Marohnic, AICP Director, Planning Services cc: 7-Eleven ATTN: Nathanael Gardner or Kimberly Parenzan 3200 Hackberry Road Irving, TX 75063