Loading...
HomeMy WebLinkAboutPLIRR2025-004797F3.ECE(VEP-. 12118/2025 Issue Date: 25-004797 3304 FERGUSON ROAD ICITY OF GRAPEVINE INSTALL IRRIGATION SYSTEM a.j MECHANICAL - ELECTRICAL - PLUMBING -ICRI! ' GATIP FUEL GAS PERMIT APPLICATION PER IT # BLDG. PERMIT # DATE: 12-16-2025 JOB ADDRESS: 3304 Ferguson Road SUITE # Lawn Irrigation Installation - Residential (NEW) "'--PROPERTY OWNER: GRAY—FERGUSON DEVELOPMENTS LLC' CONTRACTING COMPANY: S-mmrfflom. Irriciation LLC ADDRESS: 190 W State Hwy 114 Unit A CITY/STATE/ZIP: Southiake / TX / 76092 PHONE NUMBER: 214 - 518 - 3723 TYPE OF OCCUPANCY BUILDINGAREA I L (S-9-FTL- 1. R-3 [New Residential Construction Addons & Alterations] SINGLE FAMILY, TOWNHOUSE, DUPLEX (PER UNIT) TOTAL SQ. FOOT UNDER ROOF [New Commercial Construction or Addition) HOTELS, APARTMENTS, DRINKING/ DINING, EDUCATIONAL, ASSEMBLY, INSTITUTIONAL [New Commercial Construction or Addition] OFFICE, RETAIL, WHOLESALE, GARAGES, FACTORIES, VICE STATIONS. WAREHOUSE CITY/STATEIZIP. PHONE NUMBER: PERMIT FEES $ 33.25 $ 49.88 $ 63.18 $ 76.48 $ 83.13 $ 89.78 $ 96.43 $ 103.08 $ 109.73 $ 120.37 06AM=0 I - 500 $ 37.00 501 — 100,000 $ 17.50+.035 PER 100,001 — 500,000 $ 3,500.00+.03 SQUARE 500,001 + $15,000.00+.02 FOOT EACH TRADE 1 - 500 $ 37.00 501- 50,000 $ 32.00+.011 PER 50,001- 100,000 $ 182.00+.0107 SQUARE 100,001+ $ 582.00+.003 FOOT CONTRACT EACH TRADE IV. ANY OCCUPANCY GROUP VALUATION OF WORK I 51AA- RAIMMIM IIIIIIINTILVII IF -A ZI 11F.11 11010 1 =:I 41131'ril MIK Dallas I TX / 75211 214 - 606 -6457 AMOUNT DUE 0— 500 $ 37.00 501- 1,500 $ 45.00 1,501- 3,000 $ 57.00 3,001- 5,000 $ 72.00 5,001- 50,000 $ 27.00+.009 50,001- 100,000 $ 127.00+.007 PER 100,001- 500,000 $ 327.00+.0015 DOLLAR IVALUATION 5V0,001 + $ 1,327.00+.003 EACH TRADE IRRIGATION SYSTEMS $ 37.00 MOBILE HOME SERVICE $ 37.00 TEMPORARY POLE SERVICE $ 37.00 SWIMMING POOLS $ 37.00 SIGN ELECTRIC $ 37.00 RESIDENTIAL A/C & W/H Change Out $ 37.00 MF A/C & W/H Change Out (per Unit) $ 37.00 $ 37.00 37.00 HEN PLANS ARE REQUIRED rr ORDINANCES,OR AS DETERMINED BUILDING OFFICIAL, THREE (3) SETS OF PLANS SHALL BE SUBMITTED IN HARD COPY FORMAT. ENGINEER SEALED PLANS ! CALCULATIONS SHALL BE SUBMITTED AS REQUIRED BY CODES,ORDINANCES OR WHERE OTHERWISE REQUIRED BY STATE LAW. OTHER INSPECTIONS AND iNFEES ...................... ............................................... ..................... ...... ............. $42.00 INSPECTIONS FOR WHICH NO FEE IS SPECIFICALLY INDICATED # $42.00/HOUR ADDITIONAL PLAN REVIEW REQUIRED BY CHANGES,ADDITIONS,OR REVISIONS TO APPROVED Y r r • SHALLBUILDING PERMIT FEES FOR THE GRAPEVINE-COLLEYVILLE INDEPENDENT SCHOOL DISTRICT OF ' ': r IN THIS TABLE FOR USE OF OUTSIDE CONSULTANTS FOR PLAN CHECKING AND INSPECTIONS, OR BOTH ......... ACTUAL COSTS — FOREGOING IS i-' TO THE BEST OF i r AND ALL WORK WILL BE PERFORMED ACCORDING i THE DOCUMENTS APPROVED BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND / OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS, AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST. y: y y o 4rmn4,e?- §1 #` HOMEOWNER FOR HOMEOWNERS i„EMAIL: OR THE TOTALHOURLY i TO THE JURISDICTION` IS GREATER. "ACTUAL COSTSr ADMINISTRATIVE ANDOVERHEAD COSTS. Building Services Department The City of Grapevine * P.O. Box 95104 * Grapevine, Texas 76099 (17) 410-3165 (817) 410-3166 C:FORMS-ABS Appiicatioos—Fees1MEP Application Revised: 1-2024 City of Grapevine PO Box 95104Permit Grapevine, Texas 76099 817) 410-3166Project 7 Project Description: Install New Residential Irrigation System [ELECTRONIC REVIEW] Issued on: 12/30/2025 at 5:00 P LEGAL Ferguson Place Bilk 1 Lot 16 PERMIT HOLDER 'r Mario Hernandez SAi--XF1#w Irrig2rdix, 606-6457 COLLABORATORS Hernandez SmartFlow Irrigation, LLC 606-6457 a�m Irrigation Inspectionr, Device Inspection 2. Letter of Compliance (Irrigation) 5. Plumbing Customer Sevice Inspection 3. TCEQ Backflow Certification Submit 6. Plumbing Final —APPLICANT ' • r "APPLICANT PP PHONE ri VALUATION r• � RMMNVIMM-•� Mario Hernandez 214 6066457 3600 IRRIGATION PERMIT APPLICATIO - 3304 Ferguson.pdf 3304 Ferguson Rd Irrigation Plan.pdf TOTAL PAID DUE 37.00 $37.00 $37.00 $ 37.00 $37.00 $0.00 I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDINGTo THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMI DOES NOTR+ OR AUTHORIZE ANY • ' • OF ANY •r OR ORDINANCE rr OF GRAPEVINE. FURTHER CERTIFY + ALL WORK THAT IS REQUIRED •RD •,COMPLY FEDERAL,ANY AND OR LOCAL LAW REGARDING CONSERVATION WILL BE PER•- r IN ACCORDANCETHOSE • THAT VERIFICATIONOF -GY CODE COMPLIANCESHALL SUBMITTED TO THE CITY UPONREQUEST Page 1/2 MYGOV.US 25-004797, 12/30/2025 at 5:00 PM Issued by: Amanda Robeson Plumbing- Irrigation Permit Project # 2-00477 i� . i . . • � i+ `' i ` is •i •` •` • ` • i NOTES > 24 HOUR INSPECTION METRO (17) 410-3010, CUT OFF TIME FOR A.M. INSPECTION IS 7: 0 A.M. --- CUT OFF TIME FOR P.M. INSPECTION 11:0 P.M. > PERMIT ISSUED IN ACCORDANCE WITHAPPLICATION IL IN THIS i . i` � • i :i i. • •� Page 2/2 MYGOV.US 25-004797, 12/30/2025 at 5:00 PM Issued by: Amanda Robeson 7 i—GPM I r r i L, I-t on LcL�end J 0 1 4 j 4 4 4 4 '4 GPM cl, '4 1- Y 4" Residence 1104 Fer-uson Rd 4 V 1 13." ;j I C 4 SWM_j �Z x LE. l 2 2 GPM, v Z 4 Ll I t e I 11,Sidewalk, r 3 -J M PM rd, .1. 1 4 F­d W4 t 1, S:w Atlow Ai embl Yes Trol val"C", ll _;n ;a V*/- :Q�­Nf- s1rillers t !,!lets ru,ll.n V,e,sofitl [A 11 C imal Line Pip, 111m, PIP, 1, Tubmg C 01 Mario Hernandez 10 23568 C, " -7 0 10 20 40 1' = 20* — SHEET — — — — — — — ---------- DESCRIPTION: PLAN IRRIGATION SCALE: I 2U' 0" n 11) I. 4�1 rr 4� SprilILler 1 �Al S"'; F I '1. 23 it,fl: Dr.p Due Datl t CFI -CTRAY-FERGtTS0\ DEVELOPMENI'S ,;04 Fer-uson Road Urajievine. Texas 76092 FERGUSON` PLACE BLOCK I . UTF 16 TAMMT COUNTY Run Sct: 7 W cyl M > -n .4. m t'4 p, r— M -4 < M w > 0 Z 00 Z > ul 0 m I, C10111111 ;4' ep ' -11, Wq]Im� INSTALLATION NOTES) SNIARTFlow Irrigation, LLC owa OW L", Ha�l,�nda\ Dl—'t �01 Texas Commission on Environmental Quality BACKFLOW PREVENTION ASSEMBLY TEST AND MAINTENANCE REPORT The followia- form must be comt letedfm each assembl, tested. A si: ied and dated ofidnal must be submitted to the i,ublic water supi,lier for recordkeepin,_- *I, wl-oses: 1 1 NAME OF PWS: i Grapevine PWS ID#.- —2200013 PWS MAILING ADDRESS, 5.01 Shady Brock NTA PWS COCT PERSON: Backfiow Coordinator ADDiFE—SS00 SERVICE: 3304 FERGUSON ROAD GRAPEVINE, TX 76092 The backflow prevention assembly detailed below has been tested and maintained as required by comn-dssion regulations and is certified to be operatjn_ within acceptable parameters. TYPE_ OF BACKFLOW PREVENTION ASSEMBLY (BPA): C] Reduced Pressure Principle (RP A) El Reduced Pressure Principle -Detector (RPBA-D) Type 110 T - - - Double —Check —Valve (DC' VA) 11 Double Check -Detector (DCVA-D) Type 11:171 ET Pressure Vacuum Breaker PVSpiII -Resistant Pressure Vacuum Breaker (SVB) Manufacturer: Main: Bypass- Size: Main: _YN Bypass:I; Model Number: Main: o bypass �. BPA Location: Serial Number: Main: & B7-, Bypass' I PA Serves: il PERMIT NUMBER: 25-004797 Reason for test: � New X Existing I Replacement Oi Old Model/Serial is the assembly installed in accordance with manufacturer recommendations, and/or local codes? i I 0yes i[]!No Is the assembly installed on a non -potable water supply (auxiliary)? I ;Yes No TEST RESULT Type 11 Reduced Pressure. Principle Assembly (RPBA) Assembly PVB & SVB PASS DCVA Relief Valve Bypass Check Air Inlet Check Valve FAIL 171 1" Check Check*** Irdtial Test Held at­0 -�1 psid Held at.71 4, psid Opened at Held at' psid Opened at i psid Held at Date: -2 > Closed Tight Closed Tight psid Closed Tight :171: Did not open i psid Leaked Leaked Did not E3 Leaked Did it fully open Leaked P open (Yes;;[]: /No Ell) Repairs and Main: Materials Used** Bypass: Test After Held at psid Held at Opened at:! Held atf psid Opened at psid Held at jRSWeair Closed Tight 0'Closed Tight 11 psid Closed psid Date: Tight 0 2®a check: numeric reading required for DCVA onIN Differential pressure gauge used: Potable: ,or I Non -Potable: Sled: Date tested for accuracy 12-31 -25 -Make/Mqqe1:T Midwest 845-5 12241320 Remarks: Company Name: Licensed Tester Name 01 Accuracy Backflow Brian Cox (Print/rviie): Company Address' Po Box 6832 Licensed Tester Name (Signature): McKinney, TX 75071 Company Phone #: 972-699-7156 BPAT License BP0017066 License Expiration Date: I _Q2-23-28 The above is certified to be true at the finic of testing. TEST RECORDS MUST BE KEPT FOR AT LEAST THREE YEARS [30 TAC §290.46(B)] ** LJSF ONLY MANUFACTURER'S REPLACEMENT PARTS TCEQ-20700 (Revision 04-04-20.19) Page 1 of 1 S martFlow Irrigation, LLC Mario Hernandez 4502 Las Haciendas Dr. Dallas, TX 75211 214-606-6457 Landscape Irrigation System Letter of Compliance February 24, 2026 City of Grapevine Building Inspections 200 S. Main Street Grapevine, Texas 76051 P.O. Box 95104 817-410-3166 Irrigation System Address: 3304 Ferguson Rd. Grapevine, Texas Permit/Project #: 25-004797 Irrigation Contractor / Installer (Company Name): SmartFlow Irrigation, LLC This irrigation system has been designed and installed in accordance with all applicable state, and local laws, ordinances, rules, regulations or orders. I have tested the system and determined that it has been installed according to the irrigation plan and is properly adjusted for the most efficient application of water at this time. By signing, dating and affixing my TCEQ issued Irrigator's Seal to this Irrigation System Certificate of Completion, I am certifying that I am in full compliance with the Texas Commission on Environmental Quality (TCEQ) Title 30 of the Texas Administrative Code, Chapter 344, Landscape Irrigation; Chapter 54, Appendix F, Standards for Designing, Installing and Maintaining Landscape Irrigation Systems. I, Mario Hernandez , L.I.#: 0023568, certify that the requirements and required wiring, piping, and velocity standards have been met as according to TCEQ. Respectfully Yours, Mario Hernandez, Business Owner/SmartFlow Irrigation, LLC