HomeMy WebLinkAboutPLIRR2025-004797F3.ECE(VEP-. 12118/2025
Issue Date:
25-004797
3304 FERGUSON ROAD ICITY OF GRAPEVINE
INSTALL IRRIGATION SYSTEM a.j
MECHANICAL - ELECTRICAL - PLUMBING -ICRI! ' GATIP FUEL GAS
PERMIT APPLICATION
PER IT # BLDG. PERMIT # DATE: 12-16-2025
JOB ADDRESS: 3304 Ferguson Road SUITE #
Lawn Irrigation Installation - Residential (NEW)
"'--PROPERTY OWNER: GRAY—FERGUSON DEVELOPMENTS LLC' CONTRACTING COMPANY: S-mmrfflom. Irriciation LLC
ADDRESS: 190 W State Hwy 114 Unit A
CITY/STATE/ZIP: Southiake / TX / 76092
PHONE NUMBER: 214 - 518 - 3723
TYPE OF OCCUPANCY BUILDINGAREA
I L (S-9-FTL-
1. R-3
[New Residential Construction
Addons & Alterations]
SINGLE FAMILY, TOWNHOUSE,
DUPLEX
(PER UNIT)
TOTAL SQ. FOOT UNDER
ROOF
[New Commercial Construction or
Addition)
HOTELS, APARTMENTS, DRINKING/
DINING, EDUCATIONAL, ASSEMBLY,
INSTITUTIONAL
[New Commercial Construction or
Addition]
OFFICE, RETAIL, WHOLESALE,
GARAGES, FACTORIES,
VICE STATIONS.
WAREHOUSE
CITY/STATEIZIP.
PHONE NUMBER:
PERMIT FEES
$ 33.25
$ 49.88
$ 63.18
$ 76.48
$ 83.13
$ 89.78
$ 96.43
$ 103.08
$ 109.73
$ 120.37
06AM=0
I - 500
$
37.00
501 — 100,000
$
17.50+.035
PER
100,001 — 500,000
$
3,500.00+.03
SQUARE
500,001 +
$15,000.00+.02
FOOT
EACH TRADE
1 - 500
$
37.00
501- 50,000
$
32.00+.011
PER
50,001- 100,000
$
182.00+.0107
SQUARE
100,001+
$
582.00+.003
FOOT
CONTRACT EACH TRADE
IV. ANY OCCUPANCY GROUP VALUATION OF
WORK I
51AA- RAIMMIM
IIIIIIINTILVII IF -A ZI 11F.11 11010 1 =:I 41131'ril MIK
Dallas I TX / 75211
214 - 606 -6457
AMOUNT DUE
0—
500
$
37.00
501-
1,500
$
45.00
1,501-
3,000
$
57.00
3,001-
5,000
$
72.00
5,001-
50,000
$
27.00+.009
50,001-
100,000
$
127.00+.007 PER
100,001-
500,000
$
327.00+.0015 DOLLAR
IVALUATION
5V0,001 +
$ 1,327.00+.003
EACH TRADE
IRRIGATION SYSTEMS $ 37.00
MOBILE HOME SERVICE $ 37.00
TEMPORARY POLE SERVICE $ 37.00
SWIMMING POOLS $ 37.00
SIGN ELECTRIC $ 37.00
RESIDENTIAL A/C & W/H Change Out $ 37.00
MF A/C & W/H Change Out (per Unit) $ 37.00
$
37.00
37.00
HEN PLANS ARE REQUIRED rr ORDINANCES,OR AS DETERMINED BUILDING
OFFICIAL, THREE (3) SETS OF PLANS SHALL BE SUBMITTED IN HARD COPY FORMAT. ENGINEER SEALED
PLANS ! CALCULATIONS SHALL BE SUBMITTED AS REQUIRED BY CODES,ORDINANCES OR WHERE
OTHERWISE REQUIRED BY STATE LAW.
OTHER INSPECTIONS
AND
iNFEES ...................... ............................................... ..................... ...... ............. $42.00
INSPECTIONS FOR WHICH NO FEE IS SPECIFICALLY INDICATED # $42.00/HOUR
ADDITIONAL PLAN REVIEW REQUIRED BY CHANGES,ADDITIONS,OR REVISIONS TO
APPROVED Y r r •
SHALLBUILDING PERMIT FEES FOR THE GRAPEVINE-COLLEYVILLE INDEPENDENT SCHOOL DISTRICT
OF ' ': r IN THIS TABLE
FOR USE OF OUTSIDE CONSULTANTS FOR PLAN CHECKING AND INSPECTIONS, OR BOTH ......... ACTUAL COSTS —
FOREGOING IS i-' TO THE BEST OF i r AND ALL WORK WILL BE
PERFORMED ACCORDING i THE DOCUMENTS APPROVED BUILDING DEPARTMENT AND IN COMPLIANCE
WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF
THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF
I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND / OR
LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS,
AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST.
y:
y y o 4rmn4,e?-
§1
#` HOMEOWNER FOR HOMEOWNERS
i„EMAIL:
OR THE TOTALHOURLY i TO THE JURISDICTION` IS GREATER.
"ACTUAL COSTSr ADMINISTRATIVE ANDOVERHEAD COSTS.
Building Services Department
The City of Grapevine * P.O. Box 95104 * Grapevine, Texas 76099
(17) 410-3165 (817) 410-3166
C:FORMS-ABS Appiicatioos—Fees1MEP Application
Revised: 1-2024
City of Grapevine
PO Box 95104Permit
Grapevine, Texas 76099
817) 410-3166Project 7
Project Description: Install New Residential Irrigation System
[ELECTRONIC REVIEW]
Issued on: 12/30/2025 at 5:00 P
LEGAL
Ferguson Place Bilk 1 Lot
16
PERMIT HOLDER
'r
Mario Hernandez
SAi--XF1#w Irrig2rdix,
606-6457
COLLABORATORS
Hernandez
SmartFlow Irrigation,
LLC
606-6457
a�m
Irrigation Inspectionr, Device Inspection
2. Letter of Compliance (Irrigation) 5. Plumbing Customer Sevice Inspection
3. TCEQ Backflow Certification Submit 6. Plumbing Final
—APPLICANT ' • r
"APPLICANT
PP PHONE ri
VALUATION
r• �
RMMNVIMM-•�
Mario Hernandez
214 6066457
3600
IRRIGATION PERMIT APPLICATIO -
3304 Ferguson.pdf
3304 Ferguson Rd Irrigation Plan.pdf
TOTAL PAID DUE
37.00 $37.00 $37.00
$ 37.00 $37.00 $0.00
I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF
MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDINGTo
THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN
COMPLIANCE OF GRAPEVINE CODES REGULATING
CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMI
DOES NOTR+ OR AUTHORIZE ANY • ' • OF ANY •r OR
ORDINANCE
rr OF
GRAPEVINE.
FURTHER
CERTIFY + ALL
WORK THAT IS REQUIRED
•RD •,COMPLY
FEDERAL,ANY AND OR LOCAL LAW REGARDING
CONSERVATION WILL BE PER•- r IN ACCORDANCETHOSE
• THAT VERIFICATIONOF -GY CODE COMPLIANCESHALL
SUBMITTED TO THE CITY UPONREQUEST
Page 1/2
MYGOV.US 25-004797, 12/30/2025 at 5:00 PM Issued by: Amanda Robeson
Plumbing- Irrigation Permit
Project # 2-00477
i� . i . . • � i+ `' i ` is •i
•` •` • ` • i
NOTES
> 24 HOUR INSPECTION
METRO (17) 410-3010, CUT OFF TIME FOR A.M. INSPECTION IS 7: 0 A.M. --- CUT OFF TIME FOR P.M.
INSPECTION 11:0 P.M.
> PERMIT ISSUED IN ACCORDANCE WITHAPPLICATION IL IN THIS i .
i` � • i :i i. • •�
Page 2/2
MYGOV.US 25-004797, 12/30/2025 at 5:00 PM Issued by: Amanda Robeson
7
i—GPM
I r r i L, I-t on LcL�end
J 0 1 4
j
4 4
4 4 '4
GPM
cl,
'4
1-
Y
4"
Residence
1104 Fer-uson Rd
4 V
1 13."
;j I
C
4
SWM_j
�Z
x
LE.
l
2 2
GPM,
v
Z
4 Ll
I t e I
11,Sidewalk,
r
3
-J
M PM
rd, .1. 1 4
Fd W4
t
1, S:w
Atlow Ai embl
Yes
Trol val"C",
ll
_;n ;a V*/- :Q�Nf-
s1rillers t !,!lets
ru,ll.n V,e,sofitl
[A 11 C
imal Line Pip,
111m, PIP,
1, Tubmg
C
01
Mario Hernandez 10
23568
C, "
-7
0 10 20 40
1' = 20*
—
SHEET
— — — — — — — ----------
DESCRIPTION:
PLAN IRRIGATION
SCALE: I 2U' 0"
n 11) I.
4�1
rr
4�
SprilILler
1 �Al
S"'; F I
'1. 23 it,fl:
Dr.p Due Datl
t
CFI -CTRAY-FERGtTS0\
DEVELOPMENI'S
,;04 Fer-uson Road
Urajievine. Texas 76092
FERGUSON` PLACE BLOCK I . UTF 16
TAMMT COUNTY
Run Sct: 7
W cyl M
> -n .4. m
t'4 p,
r—
M -4 <
M
w
> 0
Z 00
Z
> ul
0
m
I, C10111111 ;4'
ep ' -11,
Wq]Im�
INSTALLATION NOTES)
SNIARTFlow Irrigation, LLC owa
OW L", Ha�l,�nda\ Dl—'t
�01
Texas Commission on Environmental Quality
BACKFLOW PREVENTION ASSEMBLY TEST AND MAINTENANCE REPORT
The followia- form must be comt letedfm each assembl, tested. A si: ied and dated ofidnal must be submitted to the i,ublic water supi,lier for recordkeepin,_- *I, wl-oses:
1 1
NAME OF PWS: i Grapevine
PWS ID#.- —2200013
PWS MAILING ADDRESS, 5.01 Shady Brock
NTA PWS COCT PERSON: Backfiow Coordinator
ADDiFE—SS00 SERVICE: 3304 FERGUSON ROAD GRAPEVINE, TX 76092
The backflow prevention assembly detailed below has been tested and maintained as required by comn-dssion regulations
and is certified to be operatjn_ within acceptable parameters.
TYPE_ OF BACKFLOW PREVENTION ASSEMBLY (BPA):
C] Reduced Pressure Principle (RP A) El Reduced Pressure Principle -Detector (RPBA-D) Type 110
T - - -
Double —Check —Valve (DC' VA) 11 Double Check -Detector (DCVA-D) Type 11:171
ET Pressure Vacuum Breaker PVSpiII -Resistant Pressure Vacuum Breaker (SVB)
Manufacturer: Main: Bypass- Size: Main: _YN Bypass:I;
Model Number: Main: o bypass �. BPA Location:
Serial Number: Main: & B7-,
Bypass' I PA Serves: il
PERMIT NUMBER: 25-004797
Reason for test: � New X Existing I Replacement Oi Old Model/Serial
is the assembly installed in accordance with manufacturer recommendations, and/or local codes? i
I 0yes i[]!No
Is the assembly installed on a non -potable water supply (auxiliary)? I ;Yes No
TEST RESULT Type 11
Reduced Pressure. Principle Assembly (RPBA) Assembly PVB & SVB
PASS DCVA
Relief Valve Bypass Check Air Inlet Check Valve
FAIL 171 1" Check Check***
Irdtial Test
Held at0 -�1 psid
Held at.71 4, psid
Opened at
Held at' psid Opened at i psid Held at
Date: -2 >
Closed Tight
Closed Tight
psid
Closed Tight :171: Did not open i psid
Leaked
Leaked
Did not
E3
Leaked Did it fully open Leaked
P
open
(Yes;;[]: /No Ell)
Repairs and
Main:
Materials
Used**
Bypass:
Test After
Held at
psid
Held at
Opened at:!
Held atf psid Opened at psid Held at
jRSWeair Closed Tight 0'Closed Tight 11 psid Closed psid
Date:
Tight 0
2®a check: numeric reading required for DCVA onIN
Differential pressure gauge used: Potable: ,or
I Non -Potable:
Sled: Date tested for accuracy 12-31 -25
-Make/Mqqe1:T Midwest 845-5 12241320
Remarks:
Company Name: Licensed Tester Name
01 Accuracy Backflow Brian Cox
(Print/rviie):
Company Address' Po Box 6832 Licensed Tester Name (Signature):
McKinney, TX 75071
Company Phone #: 972-699-7156 BPAT License BP0017066
License Expiration Date: I _Q2-23-28
The above is certified to be true at the finic of testing.
TEST RECORDS MUST BE KEPT FOR AT LEAST THREE YEARS [30 TAC §290.46(B)]
** LJSF ONLY MANUFACTURER'S REPLACEMENT PARTS
TCEQ-20700 (Revision 04-04-20.19) Page 1 of 1
S martFlow Irrigation, LLC
Mario Hernandez
4502 Las Haciendas Dr.
Dallas, TX 75211
214-606-6457
Landscape Irrigation System Letter of Compliance
February 24, 2026
City of Grapevine
Building Inspections
200 S. Main Street
Grapevine, Texas 76051
P.O. Box 95104
817-410-3166
Irrigation System Address: 3304 Ferguson Rd. Grapevine, Texas Permit/Project #: 25-004797
Irrigation Contractor / Installer (Company Name): SmartFlow Irrigation, LLC
This irrigation system has been designed and installed in accordance with all applicable state,
and local laws, ordinances, rules, regulations or orders. I have tested the system and
determined that it has been installed according to the irrigation plan and is properly adjusted for
the most efficient application of water at this time.
By signing, dating and affixing my TCEQ issued Irrigator's Seal to this Irrigation System
Certificate of Completion, I am certifying that I am in full compliance with the Texas Commission
on Environmental Quality (TCEQ) Title 30 of the Texas Administrative Code, Chapter 344,
Landscape Irrigation; Chapter 54, Appendix F, Standards for Designing, Installing and
Maintaining Landscape Irrigation Systems.
I, Mario Hernandez , L.I.#: 0023568, certify that the requirements and required wiring, piping,