Loading...
HomeMy WebLinkAboutSFRA2026-000321 llb� I I N E rJ JOB ADDRESS: im RECEIVED: 2/4/2026 DATE OF ISSUANCE: 26-000321 1622 CHOTEAU CIRCLE SOLAR PANELS PERMIT BUILDING PERMIT APPLICATION 1622 Choteau Circle Grapevine TX USA 76051 SUITE# 03LOCK: SUBDIVISIO BUILDING CONTRACTOR (company name): SUNRUN INSTALLATION SERVICES INC CURRENT MAILING ADDRESS: 2503 N BELTILINE RD STE 130 CITY/STATE/ZIP: GRAND PRAIRIE, TX 75050 PH: # 385-491-6788 Fax # CURRENT MAILING ADDRESS: 1622 Choteau CITY/STATE/ZIP: Grapevine TX USA 76051 PHONE NUMBER: (630) 306-536,? PROJECT VALUE: $ 29,075.40 1. FIRE SPRINKLERED? YES NO — WHAT TRADES WILL BE NEEDED? ELECTRIC X PLUMBING MECHANICAL IIIIESCRIPTION OF WORK TO BE DONE: ROOFTOP SOLAR WITH BACKUP BATTERY AND MAIN PANEL UPGRADE USE OF BUILDING OR STRUCTURE: SINGLE FAMILY RESIDENCE I Total Square Footage under roof. Square Footage of alteration/addition: 274.8 P.O. BOX 95104, GRAPEVINE. TX 76099 f817) 410-3165 O:FORMS\DSPERMITAPPLICATIONS 1/02-Rev.1 1/04,5/06,2(07,11109,4/11,2/19 DDRESS 1622 Choteau Cir. Grapevine, TX 76051 LEGAL Marina Del Rey Townhouse Addition Blk B Lot 32 & Part Of Common Area PERMIT HOLDER PAUL JOYCE SUNRUN INSTALLATIO N SERVICES INC (385) 491-6788 COLLABORATORS •PAUL JOYCE SUNRUN INSTALLATION SERVICES INC (385) 491-6788 OWNERS •Andrew Vlack INSPECTIONS 1 1. Building Final INFORMATION FIELDS **APPLICANT NAME (Individual)PAUL JOYCE **APPLICANT PHONE NUMBER 8326270330 APPLICANT E-MAIL VALUATION 29076 * CONSTRUCTION TYPE VB * OCCUPANCY GROUP R-3 DOCUMENTS - MISC 01 1622 CHOTEAU CIRCLE PLANS AND SUPPORTING DOCUMENTS.pdf DOCUMENTS - MISC 02 GRAPEVINE BLDG APP.pdf APPROVED TO ISSUE ELECTRIC YES FEE TOTAL PAID DUE Building Permit Fee, ($150.00 Flat Fee) Simple Alteration $ 150.00 $ 150.00 $ 150.00 TOTALS $ 150.00 $ 150.00 $ 0.00 READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE ORDINANCE REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY AND THAT THE DESIGN PROFESSIONAL / OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR FEDERAL AGENCY(S). City of Grapevine PO Box 95104 Grapevine, Texas 76099 817) 410-3166 Building - Residential Alteration Project # 26-000321 Project Description: Install Rooftop Solar Panels with Battery Backup, Upgrade Electrical Panel [ELECTRONIC REVIEW] Issued on: 02/18/2026 at 10:34 AM MYGOV.US 26-000321, 02/18/2026 at 10:34 AM Issued by: Connie Cook Page 1/2 ADDRESS 1622 Choteau Cir. Grapevine, TX 76051 LEGAL Marina Del Rey Townhouse Addition Blk B Lot 32 & Part Of Common Area PERMIT HOLDER PAUL JOYCE SUNRUN INSTALLATIO N SERVICES INC (385) 491-6788 COLLABORATORS •PAUL JOYCE SUNRUN INSTALLATION SERVICES INC (385) 491-6788 OWNERS •Andrew Vlack INSPECTIONS 1 1. Electrical Final INFORMATION FIELDS **APPLICANT NAME (Individual)PAUL JOYCE **APPLICANT PHONE NUMBER 8326270330 VALUATION 5000 DOCUMENTS - MISC 01 GRAPEVINE ELEC APP.pdf DOCUMENTS - MISC 02 1622 CHOTEAU CIRCLE PLANS AND SUPPORTING DOCUMENTS.pdf FEE TOTAL PAID DUE Electrical Miscellaneous Fee $ 37.00 $ 37.00 $ 37.00 TOTALS $ 37.00 $ 37.00 $ 0.00 READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND / OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS, AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST. February 17, 2026 Signature Date City of Grapevine PO Box 95104 Grapevine, Texas 76099 817) 410-3166 Electrical Permit - MISC Project # 26-000322 Project Description: ROOFTOP SOLAR WITH BACKUP BATTERY AND MAIN PANEL UPGRADE Issued on: 02/17/2026 at 4:42 PM MYGOV.US 26-000322, 02/17/2026 at 4:42 PM Issued by: Courtney Cogburn Page 1/2 SHEET INDEX SCOPE OF WORK PAGE # DESCRIPTION -SYSTEM SIZE: 5.33KW DC, 11 ZKW AC PV_l .o COVER SHEET - MODULES: (13) HANWHA O-CELLS: Q.PEAK DUO BLK ML-GI0.C+410 (MD06G100A-017) PV-2.0 SITE PLAN - RAPID SHUTDOWN: (5) TESLA MID CIRCUIT INTERRUPTER PV-10 LAYOUT (MCI) ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE - ENERGY STORAGE SYSTEM W/ INTEGRATED PV INVERTER. PV-4.0 ELECTRICAL (1) TESLA: POWERWALL 3 1707000-XX-Y, 13.5KWH, 11 ZKW INVERTER OUTPUT, LITHIUM -ION BATTERY (WEIGHT: 2911 LB PV-5.0 SIGNAGE EACH) PV-5.1 SIGNAGE 2 - BACKUP GATEWAY: (1) 200A TESLA POWERWALL CONTROL PANEL RACKING: ALPHATRACK TO FRAMING - SNR-DC-00370 SPAN PANEL INSTALLED AS MAIN PANEL, NEW 226 AMP SPAN MAIN PANEL WITH 200 AMP MAIN BREAKER TO BE INSTALLED. 11:4 Fil I Is] 11 AMPERE IM; ALTURNAHNG GURRENI Arc AR4 FAM-1 01ROAT NTEkOPIER AZIM f0MUTH c MAP C(5MPO:.JTION DC DIRECA CURRENT (E) EXI�JJNI; F,;`; ENF.R,Y `aPORAIE SY,,um Wp MAN SERVICE PANEL (N) NEW PRE-FAB PRE-FABRIGATED PIF P0UN0,PCR:,0JJAREF0QT Pv PH,)TOVOLTAC RED WIN `,HUTOOVVN DEVICE v VOLTS w WAT I GENERAL NOTES - ALL WORK SHALL GENERALLY CONFORM WITH 2021 IRC/IBC/IEBC, ASCE 7-16 & 2018 NDS, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020, ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PHOTOVOLATIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.41(A) MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703, SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE 1, OR TYPE 11 MODULES, ARE CLASS A FIRE RATED, RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690,12(1), CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(% ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT, LIJ 11,26 AMPS MODULE SHORT CIRCUIT CURRENT. 17,59 AMPS DEBATED SHORT CIRCUIT CURRENT [690,8 (a) & 690,8 (b)]. (o THE CAPACITY OF THE STANDALONE SYSTEM SUPPLY SHALL BE EQUAL TO OR GREATER THAN THE LOAD POSED (14 w BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER NEC ARTICLE 710.15(A) C) 0 ALL PASS -THROUGH CONDUCTORS MUST COMPLY WITH NEC 312.8 NEC 2020 705.12(B)(3)(3): THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR, < C14 UJ w o < Lij c\I r) > Ce) C14 < ol -J LLJ (o 0 Zo W N T- U) DESIGNER: (415) 580-6920 ex3 RIA CAPISTRANO SHEET REV NAME DATE COMMENTS COVER SHEET REV:Al 1/29/2026 PAGE PV-1.0 - ARRAY TRUE M AG PVAREA SITE PLAN - SCALE = 1/16' =1 "-0" PITCH AZIM AZIM (SQFT) AR-01 27"' 1' 358' 169,09 105,68 CHOTEAU CIRCLE AR-02 27' 181' 178' NOTES: • RESIDENCE DOES NOT CONTAIN ACTIVE FIRE SPRINKLERS, ARRAY DETAILS: TOTAL ROOF SURFACE AREA: 1668 SO FT. FIRE SETBACKS TOTAL PV ARRAY AREA: 274.8 SO FT. (3- TYP) (E) RESIDENCE sPERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREArrOTAL ROOF SURFACE (E)ATTACHED RESIDENCE AG (N) ARRAY AR-01 AREA) 100 = 16.5%, INV ATE, SMRS &Aft tj I 26447 (N)ARRAY AR-02 FIRE SETBACKS (E) ATTACHED (TTYP) RESIDENCE r, om -og, AC MD P 4 (E)DETACHED STRUCTURE CUSTOMER RESIDENCE: ANDREW VLACK 1622 CHOTEAU CIRCLE, GRAPEVINE, TX, 76051 TEL. (630)306-5368 z! 7� �A -APN 00595098 NOTE: ROOFTOP MODULE LEVEL RAPID i PROJECT NUMBER: 351 R-622VLAC SHUTDOWN DEVICE INSTALLED PER NEC I PH M 69012 ILG D I�L'lj' or' LET,INV w1INLEGEND RDS REMOTE DISCONNECT INVERTER(S) R� BACKUP LOADS PANEL MICROGRID a INTERCONNECT DEVICE SOLAR INTERIOR EQUIPMENT MODULES DASHED o L SHOWN AS DASH DESIGNER: (4 15 580-6920 ex3 RIA CAPISTRANO _v,_ljLAPPEAf4 ]N >IfE PLAN UTILITY 0 AC SWITCH FRA'4KLIN GENERATION PANEL [E METE' ADAPTER BATTERY SHEET SITE PLAN UMONcOR METER 99 AC DISCONNECIRS) FAPBOX e METER ADAPTER ENERGY STORAGE Q NT MOU REV: 1/29/2026 MP MAIN PANEL DC mF___l DC DISCONNECTS) CB a IQ COMBINER BOX 0 PV LOAD CENTER SYSTEM (ESS) SNR SNR MOUNT SKIRT PAGE RSUB -PANEL PV-2.0 ROOF INFO FRAMING INFO Max CC Name Type Height Type Span Spacing COMP SHINGLE- AR-01 1-Story 2X4 PRE -FABRICATED TRUSSES T,1' 24" ALPHATRACK R-02 COMP SHINGLE - 2-Story 2X4 PRE -FABRICATED TRUSSES T- 1 24" ALPHATRACK DI - AR-01 - SCALE: 118' = 1`-0' AZIM: I' PITCH:27* 3'-2" 6'-2- 4'4" 4-Z Detail ALPHATRACK TO FRAMING - SNR-DO-00370 ALPHATRACK TO FRAMING - SNR-DC-00370 D2 - AR-02 - SCALE*. 4/8" AZIM:181" PITCW27' ATTACHMENT INFORMATION DESIGN CRITERIA Max Landscape Max Landscape Max Portrait Max Portrait Con1guration MAX DISTRIBUTED LOAD: 3 PSF OC Spacing Overhang OCSpacing Overhang SNOW LOAD: 5 PSF WIND SPEED: 6-4- 2'4' T-0" 2'-0" STAGGERED 115 MPH 3-SEC GUST. FASTENERS: 6',0" 2'4' T0" 2'-0" STAGGERED (1) 5116"DIA S.S. LAG SCREW: 2.5' MIN EMBEDMENT INTO FRAMING 4'4" 6'-2" 3'-3" T-1 1' 0 21 -6" 0 22'4" 6-0" 0 oa 4%9" 4',1 - T6' INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. - IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" (48" FOR TILT KITS) BOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" (48'FOR TILT KITS) BOUNDARY REGION ONLY AS FOLLOWS: - ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50% - ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 115TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS. 26447 nlII " .0 'wr .. ""'o—ME, TI e3. 17; 009, CUSTOMER RESIDENCE: ANDREW VLACK 1622 CHOTEAU CIRCLE, GRAPEVINE, TX, 76051 FL, (630) 306-5368 _APN 00595098 PROJECT NUMBER: 351 R-622VLAC DESIGNER: (415j580-6920 ex3 RIA CAPISTRANO SHEET LAYOUT REV: Al 1/29/2026 PAGE PV-3.0 NEW 225 A SPAN MAIN PANEL WITH 200 AMAIN BREAKER �—==g 4 A BACKUP(E)LOADS NEW 200A BACKUP L+ATE`I,IAY ATEVIAY a 1N"4110)Xi-Yi tl IH i ER MAIN HRFAhF:R (N)LOCKABLE (N,t_tiCKAC+LE BLADE TYPE BLADE TYPE AC DISCONNECT AC DISi.UNNECT A r:r}11 J ��- IN%IN Ef:NA, PAN�O � SuUARE D -,UAREE D WITHP) GOA BREAKER DU222RB DU222RB sR, 60A, 2P 3R, 60A, 2P 120,«NOVA+:, 1: 012,10VAF p Oit4t OF IP41ERC"N'iE-- 'GI"N t4E, 2�12Q TOS t'1iBti'+,(?+, U?rtu BREAKER 'IT OPPr 917F, RID UP BU5FAR •futE'fER NU'A HER 1 �(�''+'3.tht r • RE 4'LACF EXIST NG 2011\, 20LA MAIN PANEL Nl -H NEV 2,iA 12:"CA 5PAN TIAIN PANEL • Ei1I"II PhdE N1 C;HARA;7ER1�7i-S INCLUDED IN SPU SHFETS •NOTE TJTAL'YSTEM BACKFEED -t„) QA I TEED FOR NTERC`?NNECTION'"AL•:.ULATI C'N; INV RTEE. rESLA PlWzR14AL, 3 110000-XX=I , EN E-RGY STORAGE: TE SLA PQR(ERWALL.3 170"00V-XX-Y 1150u WAIT 2-u1V INVERTER I 1.3 HATIMIA (I('E LL5 - -- : ) PEJ1K GUc; Di Y, i-IL G 10 C * 4)1 l i1APOACA V 01, } bTRI NG 1 wl rH 5 P ODULES PlITH 2 MCI 1,00N I' E-TRING 2 WITH 6 MODULFS J Box WITH IBCI CC'UiiT,MODULE LEVEL RAPID SHUTDOWN DEVIi,F:S __tom T 11! LOAD RATED DC. C, CONNgr"1ni11'HA"ri.iR.4PfD SHIfTG�i1r,IP3 CC+IJFUF.fdT -_ - CONDUIT SCMEDULE TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT 1 Inverter Input (4)10 AWG (PV WIRE) ( N/A 10 AWG (BARE) Open Air 2 Inverter Input (4) 10 AWG TH HN/THWN-2 N/A 10AWGTHHN/THWN-2 314EMT 3 Inverter Output (2)6AWG THHN/THWN-2 (1)6AWG THHN/THWN-2 8AWGTHHNITHWN-2 314EMT 4 Panel Feeder (2)2/OAWGTHHNl1-HWN-2 (1)2/0AWG THHN/THWN-2 4 AWG T H H NIT HWN-2 1-112EMT 5 Gateway Feeder (2) 210 AWG TH4N/THWN-2 (1) 2/0 AWG THHN/THWN-2 NONE 1-112 EMT SU'1RU'1 .- - 26447 - _- - , - - - - '9 in tf .tnt{ 1gCV-0Nn 100 Vj tr -vd r;R"In --lc, CUSTOMER RESIDENCE: ANDREW VLACK 1622 CHOTEAU CIRCLE, 4 GRAPEVINE, TX, 76051 I TEL. (630) 306-5368 APN 00595098 ;I PROJECT NUMBER: 351 R-622VLAC DESIGNER: (4151580-6920 ex3 _ RIA CAPISTRANO SHEET ELECTRICAL REV: Al 29l2026 _ = y PAGE PV-4.0 INvERTERI WARIING C 77-77, u tit 7 ELECTRICAL SHOOK HAZARD TERMINALS ON LINE AND LOAD LABEL LOCATION SIDES MAY BE ENERGIZED IN NVERTERI,), DO DISCONNECT IS) THE OPEN POSITION PEP, COOELS) NEC2020 6905?, LABEL L OCATION NVERTER(S), ACIDCDISCCNNECTISL AC COMBINES PANEL (IF APPLICABLE) PER CODE!S) NEC. 2020F90 1,'i51 &WARNING THREE POWER SUPPLY SOURCES: UTILITY GRID, BATTERY AND PV SOLAR ELECTRIC SYSTEM LABEL L9CATICN_ 'JTI LITY SERVICE METER AND MAIN SERVICE PANEL PER CODE(S!: NEVI, 2020: 705 12yC) pOMR SOLIENiE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION ADJACENT TO PV EIREAKER AND E'._,S OCPD (IF APPLICABLE) PER CODBS) NEC 2020: 705 14130)(2) &WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BJSBAR LAeiEL LOCATION PV LOAC CENTER (IF APPLICABLE) AND ANY PANEL. THAT UTILI ZES, THE EURI OF BREAKERS RULE" PER C'C DE(SI: NP, 2C�20:706 12;13)f3l(2 L F! LABEL LO_ATI ON INSTALLED Wl'HIN a'OF RAPID St I_T DOWN SW[TI'l-lPERCODE(S) NF132020 6'305A!Ck2LIFC 20 111 1204 5 -� LABEL LOCAT1,1N I NTERI')R AND EXTERIOR DC CONDUIT EVERY 10 FT, AT CAI-H TURN, ABOVE AND BELOW PENETRATIONS ON EVERY jBIPUI L BOX CON]'AI NINE DO 01 RI-1.11 T PER CODE(S) NEC 2020 590'M(D)Q) A L L jiffi if LABEL LOCATION AC CISCONNECTISi, PHOTOVOLTAIC SYSTEM PONT OF INHER,-,ONNECTION PER CODEISy NEC 2CSC 650 54 4' S'O'LAR Ply' SYSTEM EQUIPPED NTH RAPID SHUTDOWN TURN RAPID SHUTDOWN /\�11\ SWITCH TO THE "OFF" r— _S0_LA_R___j JELECTRtCF'VI I PANELS I POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY, LABEL LOCATION ON ER NO NIC)NE THAT iM13FT) FROM THE SFRVICE DISCONNECTING MEANS 10 WHICH THE FVSYSTEMS ARE C3NNECrED PERCODEIS) NEC2020 NOTES AND SPECIFICATIONS SIGNS AND LABELS �,HALIL MEET 1HE OF THE NEC 202�3 ARTICLE 110 21(8), UNLESS SPEOFJC INSTRUCTIONS ARE REOUIRED BY SECTION 690OR IF REQIJIESTED BY 1HELOCAL AHJ, SIGN' AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS .LABELS SHALL BE PERMANENTLY AFFIXED TOTHE EQUIPMENT (DRV41RINr METHOD AND SHALL NOT BE HANDWRITTEN .LABEL. SHALL. SEOFSUFFICIENT DUrAP[t.ITYTOWITI-ISTAND-rHEEN-VIRONMENI INVOLVED SIGNS AND I. ASELS SHALL COMPLY WITH ANSI Z5-,5 4 2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESSDTHrRWI SE SPECIFIED CO NOT COVER EXISTING MANUFACTURER LABELS '/J.\CAUTl0N I ENERGY STORAGE SYSTEM PWETTTllSEbTT­ "N ENERGIZED AFTER LOSS OF UTILITY POWER LABEL LOCATION I NVERI ER, Sr, AC;EC DISC ONNEC T IS I, AC COMBINER PANEL 0 F APPLI CABLE) PER CODE[$) NEC: 2020 7Fr, 15(C) 28447 TI I"Tonle -og, CUSTOMER RESIDENCE: ANDREW VLACK 1622 CHOTEAU CIRCLE, GRAPEVINE, TX, 76051 REV:Al 1/29/2026 PAGE CAUTION,■ MULTIPLE SOURCES OF POWER SOLAR PANELS ON ROOF C� F. MAIN PANEL (INT) UTILITY METER -AC DISCONNECT AC DISCONNECT -BACKUP GATEWAY -INVERTER & ENERGY STORAGE (EXT) 1622 CHOTEAU CIRCLE, GRAPEVINE, TX, 76051 PER COMS) NEC 2020 705 10, -, 10 LABELING FORMAT LABELS SHALL BE RED PLASTIC MATERIAL WITH ENGRAVED WHITE LETTERS MADE OF DURABLE ADHESIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. LETTERS SHALL BE MINIMUM 318" IN SIZE. Astra v 2 180 1;25'2026 07 41 AM CAT 1 ■ Subject Structural Certification for Proposed Residential Solar Installation F-19352 Job Number 35 1 R-622VLAC' Rev At Client ANDREWVLACK Address 1622 Chateau Circle, Grapevine. TX 76051 ft Arta To Whom It Clay Concern Exp 12 31,2026 Digitafly signed On 01'2926 A field observation of the existing structure at the address indicated above was performed Structural evaluation of the loading was based on the site observations and the design criteria listed below. Design Criteria 2021 IRC!lBQ IEBC- ASCE 7-16 & 2018 NDS Basic (Category 11) Wind Speed V=115 mph, Exposure B Ground Snow, Load = 5 psi Based on this evaluation, I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the applicable existing andior new building code provisions referenced above Additionally, I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the manufacturer's specifications. Results Summary (Hardware Check Includes Uplift Check on AttachmentstFastener, Structure Check Considers Main Structure) Orientation Attachment Spacing/Cantilever Configuration Mzx0CR Result j Landscape 72 20 Stacked 32q. Pass AR-01 Poftrart 45.24 Stacked 479, Pass Roofing Material Pitch Structure Check Comp Shingle 27` -Pass Orientation Attachment Spacing/Cantilever Configuration Max OCR Result Landscape 72 23 Stacked 32% Pass AR-02 portrat 4@ 24 Stacked 47% pass Roofing Material Pitch Structure Check Comp Shingle !a! 27* Pass n� ::Zam 225 Bush St. Suite 1400 San Francisc:� ��i 2: 2t CA 9di0 -1 ;111 111 � 11irl 1�1111 1-71111TVIE! 'I; . -111 11111111 � --I- . nn�� Part #1 - Section 220.83(A) j1) General Liqhtinq/Receptacles (Ci), 3 VA per sq ft: Building Square Footage VA (watts) Amps House 1756 5268 21.95 Amps Box AJVA) Total for Part #1: 21 95 5268 Part #2 - Section 220.83(A)(2),(4) a, b, c, d - Appliances and Dedicated Circuits: Dedicated Circuit Size in VA Dedicated Circuit Size in VA Water Heater 5760 NIA Spa/Hot Tub 9600 N/A Stove 9600 N/A Dryer 5760 N/A Refrigerator 1000 N/A Microwave 1600 N/A Disposal 600 N/A Dishwasher 1000 N/A Laundry 1500 N/A Appliance Circuit(s) 3000 Amps Box B (VA) N/A Total for Part #2: 164,25 39420 Total VA from Parts #1 and #2 combined: Total VA 44688 Box A + Box B = 44688 first Remaining VA @ 40% Remaining VA = 36688 36688 x 40% = 14675,2 VA Adding First 8,000 VA 8000 VA Appliances & Dedicated circuits: 22675.2 VA T AMP 4an. I c Appliances & Dedicated circuits: 94.48 Amp: Part #3,- Section,�20.8UA Heati d ' .'C loads: '-A none ttiolarga-0 sd 6 pf,,t iftr-thsHeat ing r the A/C loads togther 30% of all the Heating or A/C loads in VA: 17280 jq( of all the Heating or AIC loads in Amps: 72 Totals from all Parts VA Volts Parts #1 & #2 22675.2 240 Part #3 17280 240 Total VA for all Parts: 39955.2 I 0 Totals Service/Feeder Load 166.48 .7 Panel 1 of 5 Bus Rating: 200 Main Rating: 200 Panel % of Sq.Ft: 0% Panel % of 100% VA: 0% Itemized House and 240V Loads for Panel: (VA) .................. Not Fed by other panels Feeds: Panel 2 64.47 Feeds: Panel 3 60.89 Feeds: Panel 5 41.11 Cc�Panel) 6Tots Load Calc: 166.48 Panel 2 of 5 Bus Rating: 225 Main Rating: 200 Panel % of Sq.Ft: 0% Panel % of 100% VA: 34.37% Itemized House and 240V Loads for Panel: (VA) A/C Unit - 240V 7680 Water Heater 5760 Furnace/Heating - 240V 1680 Spa/Hot Tub 9600 Furnace/Heating - 240V 1200 Fed by: Panel I Load Calc: (This Panel) 64A7 Total Load Calc: 64.47 .. Total ''I I I I'll I'll VITIT.-STOM Bus Rating: 200 Main Rating: 200 Panel % of Sq.Ft: 70% Panel % of, 00% VA: f .0� Itemized House and 240V Loads for Panel: (VA) -a Furnace/Heating - 240V 13440 Lisp M frr 'j�lr 1:600�,,F: i Stove 9600 Dish",sher I OOC; Dryer 5760 launt �y I& Refrigerator 1000 Appt::�::�:::::�IC'eii 1,11 lf'10113'. Microwave 1600 Appljoce Circuit 2 ZZ Fed by: Panel 1 Feeds: Panel 4 2,23 . .. .. .. .. .. ... 5869 . . . . .. ............... Total Load Clc: 60.89 ...................................................................................... :FR! Bus Rating: 100 Main Rating: 100 Panel % of Sq.Ft: 20% Itemized House and 240V Loads for Panel: (VA) Fed by: Panel 3 Load Cale: (This Panel) 2,23 Total Load Cale: 2,23 Bus Rating: 100 Main Rating: 60 Panel % of Sq.Ft: 10% Itemized House and 240V Loads for Panel: (VA) A/C Unit - 240V 3840 Fed by: Panel 1 Load Cale: (This Panel) 41.11 Total Load Cale: 41.11 Panel % of 100% VA: 236% Panel % of 100% VA: 1.18% xdlG uu ......................................................... 390-410VT�p-J-132X4Us------= 20.9% Maximum Module Efficiencl Breaking the 20% efficiency barrier ANT,. V Z. 7� A reliable investment 25 Warranty Enduring high performance 10) J­ �c!fls Ami U Extreme weather rating Lf 1. Innovative all-weather technology The most thorough testing programme in the industry d FV The ideal solution for: Rooftop arrays on SERIES Fenner --I! t,7 1,264 We,ght Front Cover Park Cover At-, i7Irl Frame ci�tk �n cell ANTW x�;): 1A Junction box )9 J �2 31" "i , %T r, 1 - �'P�-" 5 Cable 4,i,w Connector 4P,56 :—T ■ Electrical Characteristics POWER CLASS 390 396 400 405 410 A� T A AP T-, T - Power at MPP' fW-1 ;90 4266 391, 432 1, 400 4375 405 4410 410 4485 Short Circuit Current, 'X !Wll 12 05 11.04 12 1)8 1107 12 ll ii 10 1215 11 to 121S Open Citcult Voltage' 454J 4d,. a5 45 52 1568 4555 4572 455SI 45,75 45,52 45,78 Current at MPP A: to 39 11 ' 7 10.45 114: 1050 1149 10 r;6 V 55 11,:; 61 If a,1 Voltage at MPP ':Ve 3754 -q753 31 r-li �781 3P'09 38 CIS '1836 318 3S 33611 33,62 Efficiency' It !9.9 201 �20A 2 () E, 2n 9 q V 1 Pic ATA,, .FAT Power at MPP P",'. !W; 292.f 296 3 300 1 303 8 3,076 Short Circuit Current 9 W 837 6 F-9 F-92 8 4 897 Open Circuit Voltage -V42 90 42 4296 42 99 43 0� Cunent at MPP A! BAG 8,21 3.26 a 11 8 36 Voltage at MPP V: 35 86 3 E'� 11 0 36 3 3 36 57 36 fit, 5 T'_ 1 NM-sT vo: 'l'i Ocefis PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE PC, Y, ttU i�— All j.fl.1 V:4f'n .'y 7' j.. Z, TEMPERATURE COEFFICIENTS Temperature Coefficient of i,. Temperature Coefficient of V,,, Terriperatwer Crieffictent of P_ Nominal Module Operat-9 Temperature ■ Properties for System Design Maximum System Voltage V�rll PV module classification Class 11 Maximum Series Fuse Rating Fire Rating based on ANSI; UL 61730 a Max. Design Load, Push: Put€' Permitted Module Temperature Max, Test Load, PushiPull; on Continuous Duty a Qualifications and Certificates iECG121�1--'r,', !E U N: 2 ......... .. . ocells N a it; =1-107M Flash Track with Patented Umbrella Technology • Single Umbrella lag screw secures flashing and flash track to roof in one complete action • Umbrella technology provides weatherproofing with a long- lasting mechanical sea[ • Flash track is designed for maximum versatility with 6 inches of North -South adjustability for all Mounts Mounts • Single mount used at all locations on array • Extreme time saver by eliminating link interference through the flexibility of the Mount to change orientation • Features a rock -in channel nut design for easy attachment to Flash Track • Slotted riser provides leveling for easy height adjustments Links - Simple design provides mounting platform between two to four modules - Clamps onto top of modules securing them in place while providing row -to -row bonding Next row of modules easily slides into place as with the Mounts in • Easily locks to bottom of module mounts and links for clean aesthetics • Ensures a strong structure for leveling and alignment of first row of modules • Skirt length is compatible with both portrait and landscape module orientations _Dt011 �0 G I rcll�, LAMENT eevo% BE MEI �l I tdRACK 04 CON'T 1A s"O", C9,51"', BEM op cpESPANS ARE jAt4o �Ojk SO -TIO% MAW SNAPN C� 'RIO cjpOA t�s -To ER SNN?�40 v specflcp,,Tlo REFSNMA ONPA', �To?,Q" 6fjCPTlV45 fop, ,TOP,Que RN -TM )VL - ?,00f 1,1-( OIE� fklx- 1BU,T� (Oec�oc"o � �"Ovm) �AOABVI DOM?,'. ,4 2" 61513 __jpqp�? W�0, 7116" DRAB tA or-()()370 REVISION:W', ----- ------- ROOFING MNT eryING 91 ooF 0 compl-5VE-0 p,00fINO MNTEV,14, NOIAAJIRACY P,00F DECy iNO RAFT --------------------------- -- —.� AIL, -VOPS? WSW System Technical Model Number Specifications Nominal Grid Voltage (input & Output) Grid Type Frequency Overcurrent Protection Device Solar to Battery to Home/Grid Efficiency Solar to Home/Grid Efficiency Supported Islanding Devices Connectivity Hardware Interface AC Metering Protections Customer Interface Warranty Solar Technical Maximum Solar STC Input Specifications Withstand Voltage PV DC Input Voltage Range PV DC MPPT Voltage Range MPPTS Maximum Current per MPPT (1,,) Maximum Short Circuit Current per MPPT (IJ 9W119= L-Pir-l" 11 Lort k 4 • MIMI Nominal Battery Energy Maximum Continuous Discharge Power Maximum Continuous Charge Power Output Power Factor Rating Maximum Continuous Current Maximum Output Fault Current Load Start Capability (1 a) Power Scalability 1707000-xx-y 120/240 VAC Split phase 60 Hz 60 A 89% 97,5%z Gateway 3, Backup Switch, Backup Gateway 2 Wi-Fi (2,4 and 5 GHz), Dual -port switched Ethernet, Cellular (LTE/4G-) Dry contact relay, Rapid Shutdown (RSD) certified switch and 2-pin connector, RS-485 for meters Revenue Grade (+/- 0,5%) Integrated are fault circuit interrupter (AFCI), Isolation Monitor Interrupter (IMI), PV Rapid Shutdown (RSD) using Tesla Mid -Circuit Interrupters Tesla Mobile Apo 10 years 20 kW 600 V DC 60 — 550 V DC 60-48OVDC 6 13 A' 15 A` 13.5 kWh AC 11.5kWAC 5 kW AC 0 - 1 (Grid Code configurable) 48 A 10 kA 185 A LRA Up to 4 Powerwall 3 units supported 'Typical solar shifting use case, 'Values provided for 25'C (77-,F), at beginning of life, 13 kW charge/discharge power. Tested using CEC weighted efficiency methodology, The customer is expected to provide internet connectivity for Powerwall 3; collutar should not be used as the primary mode of connectivity. Cellular connectivity subject to network operator service coverage and signal strength. 5 Where the DC input current exceeds the MPPT rating, a jumper can be used to combine two MPPT& into a single input to intake DC current up to 26 A 1, / 30 A 1_ Environmental Operating Temperature —20°C to 50°C (-4°F to 122°F) Specifications Operating Humidity (RH) Up to 100%, condensing Storage Temperature —20'C to 30'C (-4°F to 86'F), up to 95% RH, non - condensing, State of Energy (SOE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Rating NEA 3R Ingress Rating IP67 (Battery & Power Electronics) IP45 (Wiring Compartment) Pollution Rating PD3 Operating Noise @ 1 m < 50 db(A) typical <62 db(A) maximum Performance may be de -rated at operating temperatures above 40 C (104oF). Compliance Certifications UL 1642, UL 16996, UL 1741, UL 1741 SA, UL 1741 SS, UL Information 1741 PCS, UL 3741, UL 1973, UL 1998, UL 9540, IEEE 1547- 2018, IEEE 1547.1, UN 383 Grid Connection United States Emissions FCC Part 15 Class B Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) Fire Testing Meets the unit level performance criteria of U L 9540A Mechanical Dimensions 1099 x 609 x 193 mm (43.25 x 24 x 7.6 in) Specifications Weight 130 kg (287 lb) Mounting Options Floor or wall mount A 0j qq 1099 mm yy 609 MM 193 mm 2024 iq;; 111 T1111111111 1111111111111111 11111111111111111 11111111111111 111111111 1111�1111 1111 -7 - HIT W-111111,• J Electrical Model MCI-1 MCI-2 Specifications Nominal Input DC Current Rating 13 A 13 A Maximum Input Short Circuit Current (Ij 19 A 17A Maximum System Voltage (PVHCS) 600 V DC 1000 V DC , Maximum System Voltage is limited by Powerwall to 600 V DC, RSD Module Maximum Number of Devices per String 5 5 Performance Control Power Line Excitation Power Line Excitation Passive State Normally Open Normally Open Maximum Power Consumption 7 W 7 W Warranty 25 years 25 years Environmental Operating Temperature -40-'C to 50*C -45-"C to 70'C Specifications (-40'F to 122, F) (-49"F to 158'F) Storage Temperature —30-,C to 70'C —30'C to 70'C (-22sF to 158-F) (-22°F to 158� F) Enclosure Rating NEVIA 4X / IP65 NEMA 4X / IP65 Mechanical Electrical Connections MC4 Connector MC4 Connector Specifications Housing Plastic Plastic Dimensions 125 x 150 x 22 mm 173 x 45 x 22 mm (5 x 6 x 1 in) (6.8 x 1.8 x 1 in) Weight 350 9 (077 lb) 120 g (0,26 lb) Mounting Options ZEP Home Run Clip Wire Clip M4 Screw (#10) M8 Bolt (5/16") Nail / Wood screw Compliance Certifications UL 1741 PURSE, UL 3741, Information PVRSA (Photovoltaic Rapid Shutdown Array) RSD Initiation Method External System Shutdown Switch or Powerwall 3 Enable Switch jj&U1j:17Aj *2 * =np � in -ma EM 1217-11111111 - muzolloTag Model Number 1841000-01-y Nominal Grid Voltage 120/240 V AC Grid Configuration Split phase Geld Frequency 60 Hz Continuous Current 200 A Rating Maximum Supply Short 22 kA with Square D or Circuit Current Eaton main breaker 25 kA with Eaton main breaker' IEC Protective Class Class I Overvoltage Category Category IV Only Eaton CSR or BWH main breakers are 25 kA rated. Operating Temperature Operating Humidity (RH) Maximum Elevation Environment Enclosure Type Certifications Emissions Mechanical Dimensions 660 x 411 x 149 mm Specifications (26 x 16 x 6 in) Weight 16.3 kg (36 lb) Mounting options Wall mount EM AC Meter Revenue accurate (+/- 0,5%) Communication CAN User Interface Testa Apo Backup Transition Automatic disconnect for seamless backup Overcurrent 100-200 A Protection Device Service entrance rated Eaton CSR, BWH, or BW, or Square D GOM breakers Internal Panelboard 200 A 8-space/16 circuit breakers Eaton BR, Siemens OP, or Square D HOM breakers rated to 10-125A Warranty 10 years —20°C to 50®C (-4-F to 122'F) Up to 100%, condensing 3000 in (9843 ft) Indoor and outdoor rated NEMA3R UL 67, UL 869A, UL 916, UL 1741 POS, CSA 22.2107,1, CSA 22,2 29 FCC Part 15, ICES 003 A (560 min Y 411 mrn �149 mrn 9 Sj *9am If Lert 11 L01 jUj7= S3Ar-1"1R*rt14L*11V*1 am= 111111DUSHN14101111 Az� omiff.-M. i=-1 EM Model Number 1624171 -xx-y Continuous Load Rating 200 A, 120/240 V split phase Maximum Supply Short Circuit Current 22 kA with breaker Communication CAN AC Meter Revenue accurate (+/- 0,5%) Expected Service Ulfe 21 years Warranty 10 years I Breaker MaXiMUM supply short circuit current rating must be equal to or greater than the available fault current. Operating Temperature Storage Temperature Enclosure Rating Pollution Rating Dimensions Weight Meter and Socket Compatibility External Service Interface —40-'C to 50'C (-40°F to 122°F) —40°C to SYC (-40°F to 185°F) NEMA3R PD3 USA: UL 414, UL 414 SB, UL 2735, UL 916, CA Prop 65 FCC, ICES 176 x 205 x 74 mm (6.9 x 8.1 x 2.9 in) 2,8 lb ANSI Type 2S, ringless or ring type Contactor manual override" Re -set button Conduit Compatibility 1/2-inch NPT ' Manually overrides the contactor position during a service event. Fz8gro"n I 't LL - L L L L L L L L L L 176 trim I` 74 mm 07 0 11 - I " - S3 fla" I I VteN; I SNUM S-Pir-#j I Nj = U111111 2024 Model Number 1232100-xx-y AC Voltage (Nominal) 120/240 V Feed -in Type Split phase Grid Frequency 60 Hz Current Rating 200 A Maximum Supply Short 10 kA Circuit Current Overcurrent Protection 100 - 200 A, Service Device entrance rated. Overvoltage Category Category IV Internal Primary Revenue accurate AC Meter (+/-0,2%) Internal Auxiliary Revenue accurate AC Meter (+/-2%) Primary Connectivity Ethernet, Wi-Fi Secondary Connectivity Cellular (3G, LTE/4G) Operating Temperature Operating Humidity (RH) Maximum Elevation Environment Enclosure Type Certifications Emissions Dimensions 660 x 411 x 149 mm (26 x 16 x 6 in) Weight 20,4 kg (45 lb) Mounting options Wall mount, Semi -flush mount User Interface Tesla App Operating Modes Support for solar self - consumption, time -based control, and backup Backup Transition Automatic disconnect for seamless backup Modularity Supports up to 10 AC - coupled Powerwalls Optional Internal 200 A 6-space / 12 circuit Panelboard breakers Siemens OP or Square D HOM breakers rated 10 - 80A or Eaton BR breakers rated 10 - 125A Warranty 10 years When protected by Class J fuses, Backup Gateway 2 is suitable for use in circuits capable of delivering not more than 22kA symmetrical amperes. Cellular connectivity subfect to network operator service coverage and signal strength. —20'C to 50°C (-4°F to 122°F) Up to 100%, condensing 3000 m (9843 ft) Indoor and outdoor rated NEMA 3R CSA 22.2 0.19, CSA 22.2 205 FCC Part 15, ICES 003 A 4 149 ► min 3� F_­ Whole Home Backup Meter Grid Meter socket panel Load center I Backuploads Whole Home Backup ut Meter Grid Meter socket panel Load center Backuploads Partial Home Backup Utility Meter b Main Breaker Grid Meter load center Non -essential loads am Load center Backuploads Solar Electrical Model MCI-1 MCI-2 Specifications Nominal Input DC Current Rating (1MP) 13 A 13 A Maximum Input Short Circuit Current (Isc) 19 A Maximum System Voltage (PVHCS) 600 V DC IOMaximum System Voltage is limited by Powerwall+ to 600 V DC, RSD Module Maximum Number of Devices per String Performance Control Passive State Maximum Power Consumption Warranty Environmental Operating Temperature Specifications Storage Temperature Enclosure Rating Mechanical Electrical Connections Specifications Housing Dimensions Weight Mounting Options Compliance Certifications Information 10 KO: 5 2 kyj U M SM41 E �Ma M• 9M S Power Line Excitation Normally Open 7 W 2S years -40°C to 50°C (-40*F to 122°F) -30°C to 70°C (-22°F to 158°F) NEMA 4X / IPGS MC4 Connector Plastic 125 x 150 x 22 mm (S x 6 x I in) 350 9 (037 to) ZEP Home Run Clip M4 Screw (910) M8 Bolt (5/16") Nail / Wood screw 17 A 1000 V DC10 5 Power Line Excitation Normally Open 7 W 25 years -4S'C to 70°C (-49'F to 158°F) -30°C to 70°C (-22*F to 158°F) NEMA 4X / JPGS MC4 Connector Plastic 173 x 4S x 22 mm (6,8 x L8 x I in) 120 g (0,26 lb) Wire Clip UL 1741 PVRSE, UL 3741, iiD, External System Shutdown Switch lie Unprecedented cost saving Customizable, flexible backup home energy insights when paired with battery storage Electrical • Revenue -accurate energy monitoring 100 - 200A Main Breaker with built in Microgrid Interconnection Device (MID)' .225A busbar rating Installation Indoor and outdoor rated Surface or serni-flush mounted Compatible with standard 1" breakers Connectivity Ethernet, WiFi, cellular Free over -the -air updates - Testa, Ffanklin' SPAN goes beyond monitoring with the SPAN Horne Apo* for real-time control and energy insights to bring your home's energy to life. Combined with battery storage, SPAN gives homeowners the power to choose and change backup or rorities whenever they want. TAITITM, I Grid Connection Single phase Additional Features Grid Frequency 60Hz Cuslornizable whole -home battery storage Bus Bar Rating 225A Backup time remaining estimates Controllable Circuit Spaces (up to) 40 Real-time load control Energy nionitoring & insights Feed-Thru Lugs Yes, two feeds Load management for upgrade avoidance Enclosure Rating NEMA 3R Max Branch Circuit Size 100A DP Energy Management System SPAN PowerUp'" capable, Backup overload protection AC Metering Revenue accurate +/- 0.5% on mains + all branch circuits Breaker Compatibility SqUareD, Siemens, Eaton, and GE Mounting Style Surface or semi-flUSh Mount AC Voltage (Nominal) 208 / 240 VAC, L-L Main Overcurrent Protection Device Max 200A Main Breaker , built in Microgrid Interconnection Device (MID) Maximum Input Short Circuit Current 22kA Enclosure Dimensions 46.0 x 14.3 x 6.5 in (H x W x D) Weight 109 In (493 kg) (enclosure no door or deadfront) 25 In (113 kg) (Panelboard) 41 In (18,6 kg) Connectivity Ethernet, Wifi (2.5, 5 GHz) Warranty SPAN Panel: 10 Years: SPAN Home Gateway: 5 years Environmental Operating Temperature Operating Humidity (RH) Maximum Elevation Environment Compliance -22 to 122°F (-30 to 501C) Certifications 0-100% Emissions 3000m Other Indoor, outdoor UL 64 UL 916, UL 869A, UL 3141 JPUj K"C' Part Tb Class 8 NE(,, cornpha pant t listed NiNve[ Contral system fot load management PRODUCT SPECIFICATIONS All soon ficatyr+s wid descripcons icomained in thn; document are accurate at -,ne time of publicaron In the interest of prcouct unpro,crioUnt, SPAN resmvics the rgil", *'a snake product moo,ficitions, at any tme wtnout advacce tropco For the latest SPAN product and irstaratityi dotonreOv visit For priors it amiss ons, contact support.giepan o For comottoe product spec ' nicat tano and,nformatieti on pecclec-,;�st,q and certification, refer to Me Product Datashoet at, wvosv saw; 4o All insiblicitions must conform to the laws, togulabon5. codes and standards apideable;,, the jurisdiction Before starimq or, iP.s' alberon consult a local building or vicrtreal inspector for current requ remont, Lactif codiss may vary Out are adoploo and unforced to promote soft,, ercctncas nstallievros A permit may pe needed to do cloctrical brcrk. a,id some codes may mqu!rc an irttexcion -f the ale,-Owa! work Jurisdiction Code ionic States National Electrical Code (ANSI NFPA 70l r9mTM. SPAN a5SUnICS no LabIdty for injury or proccrin, dantape duo to irseviation or samcc WARNING. Risk of docalc sroc-ir. Phis of fire Only qualified olactr:caf persorrel attempted by unqualified •noe, duals, or clue to a failure of,cstalers or service u,c-oiars if) should vtv'.all troublesbact, stevlco or o"oic lac"mohnipment lf'q� ,,tr prom.rIv fellow safety, installation and service i,tstructmoo WARNING Risk cdelectirc ri!;oc:A Apply appropo.cDc, personal c*roactOc 2021 SPAN 10. Inc. All bights reserved Ali oforrhation I m;S docalpent ;s sub;oct of copyright. and Other intellectual property rights of SPAN 10 Inc Tn,s material may not be mocilred reproduced or copied. sisred;n a retrieval system, Or pars.-nited, in ol"Clo or in Pon. without the vlor wrlein permtsSon of SPAN l0 Addt crat irformaitan,s avalaole upon request, Trademarks Trio foliooirg arc trademarks or ricgisporod trademarks of SPAN 11 Me United States and other couluges SPAN, SPAN 10, SPAN Parfet Ali other trademarks ino)t, docume,Tf, are TOO croccry Oftne, r n1'spQC1 V('1 Ovvniors, and tno;r use w thin does -lo- imply enclorsamort of their Products or services Tte u'laud'orized use of a,iy trademari, displayed �,, this document oro^ the, product is sti-7-6 pivurpood Electronic Device Waste Disposal Proper disposal of emoolono ecribinent is nolurod Refor to locat codes for disposal raccittements To ana,pAc for proper Ji5posa! or 1hw „troduct cwrtact your local autpointrics or dealer for proper disposal notux-nert is Warranty TO secure rue fail product wan amv- nic SPAN Film! must be req6tered bv cortcdannq rec nrocese wheh sarvis zwslcm information to SPAN For complete amocirfy ,rfor'narui ruler to the Product, %litarfanty at %, i.w span o IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS Followti-eac r-5cructonsdurng ^,,ata!latltyn, maintenance and opertorop of line cquipmern This section conta.D,, salon, r-if ienatior. tnat.rriest be OpscrVarl at all times skier atinring Dr or using rim equipment In Case of Fire or other emergency: If saff, todc 5o. swacri off the 'na: q or up5bcan' biniainc for vie pand Cooza,.c the fire deparietent or mie, rociu,Tod wnoqcrcy response learn Evacuate ti,o area ard ale:? othcry in the area In case of unusual noise, small or smoke: Ensure nothing :s rr cumard orth tire SPAN Paner or uItTur equipment "'8"t4am the sposco, 0,croett your .,,siallor Or SPAN Custorrita Supvod, Symbols Used Those symbols irdicace mportant -safety i,ifarnatcri in the documentat von or on the equementr % WARNING Incimcdco a !inure to fol'os,nocuctora� or use 0"" J-11 onerae,matenals may be a safety azard test may result in serious inory, rues of fira. or destructor, of equipment Disc caul on Ord do not proceed until ,n o cared coriditers Or tortured procedures are futp understood and mot CAUTION rniticalco a squatun short, failure lot follow instructors or use proper ma' r4sai be to safety =iazani that may rosuit,,i minor njury or damagotoeq.,pnKra recIvrod procedures are fully understood card met ig�"- 4NOTE Indicates an mpor'ar,,t stop or add canal iformaor. rtthat nighligho; '; '1 best practice-, or procedures Follow -r souctons carcluil.v, RISK OF ELECTRIC SHOCK Indicates comporents that proven! rsk of Stock PROTECTIVE CONDUCTOR TERMINAL: 'ud,caws been onty"grow d,no co,,hecto,i or, vite equiroiterh REFER TO INSTRUCTIONS Indicates t1r. ODD, should rep, to operating or ristallancri,ristructions oefeen proceed eg ATTENTION. Read ail rpsmuctions and cautionary mark:igs in ;his decunienT ard on the rrgu entent before ^,staffing ",a SPAN Panel Failure to do so may result n cquomort coinage electric shock serious injur, or loss of life Fa,hnq to folios any of Itrese midructions may also void one vervanly SPAN 1 -00800-xx Installation Manual (rev, 2022-05-30) equprrrcq'iPPE p and follow safe etectyrial 4or, pretcaces; dunog Istalafton and service Turn off all zoATr supplying this equipment before �.aork:ng on or inside uquigrros' , Always use a oupoorN rated voftaoQ sons device, sal confirm power ,a off Replace all do, iCOS, GOVOIS and doors before as,wigur, power to the ecutome'lL WARNING TO pederd the equipritent and itv itampcir`ervs frohn darnage elien trmtspopmg' nandle roth. care To help lea,e,, oil equipleent in +ts sinpowg packagng ur-An v ready in be WARNING Intutect the eclopmeril for damage bouremstallng, Dcnot :nstall urn equiphrci' :f it has open dareraged ,ri anyway WARNING. DO ounhaert toper e be ocleoh,-hr any par probe equipa I WARNING Do ^rat exposic, the equ phrent of any of Tts components rodrej:t frame WARNING Do net attempt tortoni, disassembfc, revar. uerperw,th, Or modify tiro nquipnech otrief than ,swath; {shin tbed in ih s niaruat Tire equiptnera onr-aws no user-svirocc able Darts other than fiddr-,petWicid ;nreuyt aearors Cur"acth%,s installer '00 installed tic, equipment for a"V repulfs WARNING Do not connect hfiv-su ' court systems caner medical equoment or aryotnor use 7. note product latrine could lead to;n;ury r, tiorsons Or loss Of Vc 10 C"CUrs mci can re reimoly CAUTION Do no-, use bolverits to clean tire, equ,prnent or expose the cquion"orit Ic flarninceac - harsh oncineafs or vatovics Duno;a':ow oolrotown-basord pairts. Saloom& or sprays to cviitact nonnto,al5.c parts of trui eqw0ment CAUTION. Do not use parts or accessories other that eiuso sucefed for use �N'th the oqui"Overe Installation and Use j it WARNING Risk of ejectrz shock Risk of firs Only use ciecorcal system :4, ccinpono,oc approved for set tociat irs WARNING Risk of cltcrr:c shycy. Risk of fire Ensure that all Mono ci svaect and that none of tney,,ms are pncitied or damaged WARNING Risk of electric rn.cicK, Pass: of fire Befort, makirg any connor fors ,niinfy teat the circuit ureaner'st arc ,n me off positcr, Double onecir ail wring before saply'rel goiter WARNING Rsk of electric 51101 Imprtxxy servc-g of the equ,prnortt or its components may result in a risk of cents orhyt. To reduce 01050 risks, disconnect Wlc,nrq polore attempting anynarvateraince, or cfeamrig WARNING Risk ofoleciresireck Aloays dc-overg;ze the equiprucrit befcrru servicing While Oon-Lcono art, rand for ctsconvoc, under load it is best to-actice to der -energize before ciscurn-obag WARNING Risk of efectir c sf-acK Donot use uqulixituxe :n arnanne, not sive0led by the manufacturer Doirg SO MOV CBuSE, IoUry Or lass of tkfe or damage to cQuipme,it, WARNING. Risk of electric shots. Tomaurtair, in,, oserann, donot ritial-1y the deadlimut what than to remove filter plates as needed r .fe NOTE The equ;)rnc,,i is rtended I-) operate vietr, atx',iner c of) to the intemot Failure to rraurdan an mfornet conneccor, may i1or-apt porformanew NOTE This dcuze ccorpresmth part 15 of the FCC Rules Operas on as subjo-ft to the fotioNfrg two conditions, 111 This device may net cause narrofut mterferonce, and t2a th,s device must accept any nterfereree received. Kiduding ,lerference fban may cause undes:red operstowi Clianges or modifications riot expressly approved by the party responsible foroomplem;c coufdvo�d tyro User s authuray to operatuffic equ,prnorc WARNING This cqu�onic,rt sainoldec for o0orav q " an On., mir,muintemperaorw of -30 C l-22 Fi and a maxvrnu in temperature of 5or C 022 Fl, WARNING Install the ego proutt in a iociuton that sravc,,ts damage from f(Mirg Ensure that •IoO;cder sources art above Or near rho equouroot m,ruding dOot'SPOUS. sprinklers, Or yoUpot'L ABOUT YOUR SPAN PANEL PREPARING TO INSTALL iirld {le' Pz,,re I lat; c) n - -,e r, ta H N e cl u i re i,, INSTALLATION 1 , "N'lo"Intino t�-tt, panel 2, Usin, thr, F'ane! Serlv;ce 'EC f , rnen� -in k c, i C, �ng the Dec;f- D�re,`ion, f--,w -w the Fi'Ndcuni� Tn! I ns pe -I- L o r anici the TROUBLESHOOTING & SERVICING APPENDIX A'CIRCUIT BREAKER COMPATIBILITY APPENDIX B, SURGE PROTECTIVE DEVICE COMPATABiLITY APPENDIX C: MAIN LUG PART SPAN 1-00800-xx Installation Manual (rev. 2022-05-30) 8 The SPAN Panel is an intelligent breaker panel with integrated connectivity, monitoring, and control for home loads, solar PV generation, energy storage, electric vehicle charging equipment, and the utility grid. SPAN is wall -mounted and similar in size, weight, and configuration to traditional electrical panels, allowing it to be installed in place of a typical 1201240VAC breaker panel using standard tools and materials, SPAN Panel installations can be designed to support both DC -coupled energy storage systerns (where the solar generation and battery storage systems are managed by a single inverter-) and AC -coupled systerns (where the solar generation and battery storage systerns each have their own inverter), See Storage System Integration Manual for cornplete details, SPAN Panel with door removed (top), deadfront removed (bottom) SPAN 1-00800-xx installation Manual (rev. 2022-05-30) Inspect the packaging and SPAN Panel for damage. Ensure you have received the following components: • SPAN Panel (with main bonding jumper pre -installed) and door (packaged separately) • Getting Started card (with instructions for homeowner to download SPAN Home App) • Breaker label schedule sheet • Accessories: * (1) Conduit hub closing plates (SquareD ACPCP) (pre -installed) * (2) SquareD service entrance barrier covers (pre -installed) * SquareD 200 A main breaker (pre -installed) * Spare fastener kit WARNING: if the unit is damaged in any way, do not proceed with the installation. Contact SPAN for further instructions. Internet Connection The SPAN Panel requires an internet connection to enable monitoring and control features, and to receive the latest software updates. Z� Be sure to register the product to establish communication with SPAN. Failure to do so may affect product performance or affect the terms of the warranty. If a Wi-Fi signal is not available at the install location, establish an Ethernet connection between the SPAN Panel and the customer's router. Cellular LTE should only be relied on as a backup connection. Required Equipment • Branch circuit breakers for load and gener circuits. See • Main breaker(100-200 A) using SquareD type QOM2 breakers • Conduit, conduit fittings, and Squarel) A -Series threaded conduit hub suited to the installation • Four #10 lag bolts or screws, 3 inches long (depending on attachment wait) for panel mounting, and washers (for use between fasteners arid enclosure) • Conductors rated to minimum of 75'C. See table below, and markings on breakers for acceptable wire gauge. • Cable for communication between the SPAN Panel and solar inner cer(s) (Mininium 300 V rated, shielded, twisted -pair, copper, 22-16 AWG) • Sn-tartphone or tablet with SPAN installer App for commissioning Personal Protective Equipi-nent (PPE) should be worn by all persons at the installation site and properly rated for residential applications. Required Tools • Torquing tools capable of 20-275 in-lbs (2.3-31.1 Nm) • Allen bits (3/8-inch and 5116-inch) • Phillips, slotted, and square -drive driver • Standard installation tools: wire cutters/strippers, multimeter, stud finder, level, tape measure, market-, and flashlight NOTE: Verify that the site mechanical, electrical, and clearance requirements outlined in this document and the product datasheet are compatible at the planned installation location. NOTE: Install only compatible circuit breakers, hubs, conductors, and other accessories. Failure to do so may affect safety, rl'\ product performance, and may void the warranty. NOTE: NEMA 3R rated conduit fittings are required for Outdoor installations. NOTE: For 22 kA short-circuit rating, branch breakers must be series -listed with the SquareD main breaker. Otherwise, rating will be 10 kA. SPAN 1 .00800-xx Installation Manual (rev. 2022-05-30) Electrical, Mechanical, and Environmental Requirements • The SPAN Panel is service entrance rated. When used as service equipment, primary overcurrent protection for the site is required in the form of an installed main breaker not to exceed 200 A. • The SPAN Panel is intended to be wall -mounted between studs (2x4'oi- equivalent) with 16-inch spacing, using all 4 mounting points. It is typically mounted serni-flush, so the front of the unit extends slightly beyond the surface of the wall, • Verify that the wall construction is adequate to support the weight of the panel. The installation should conform to applicable building codes. Consult a structural engineer and local standards for local mounting requirements. Site Electrical Service Service Feed Internal Bussing Overcurrent Protection (Main Breaker) Location Ambient Temperature Enclosure Dimensions Flush Ti hn Kit Dimensions (on wall) Weight (without circuit breakers) 2401120 V, 60 Hz split -phase 200 A maximum 225 A maximurn 100 - 200 A Indoor or Outdoor (NEMA 3R) -22'F to 122'F (-30'C to 50'Q 998 x 362 x 153 mrn (39.3 x 14.3 x 6.0 in) 1123 x 405 min (44.2 x 15,9 in) 34 kg 175 Ids (38 kg 184 Ids fully populated with breakers) CAUTION: Follow all local codes and standards when planning for and installing the SPAN Panel, CAUTION: Do not exceed panel capacity. Ensure that the installation conforms to applicable code, and that appropriate overcurrent protection is in place. Dimensions, Clearances, and Access • Do not install the SPAN Panel neat- an emergency exit or other building evacuation route. • Do not install the SPAN Panel in a location or place any objects near it that would prevent its door from opening to 90', or that would restrict access to the unit, • Do not mount objects on the wall within the roinin-furn required clearances indicated below, with the exception of items reqUired by the Installation, Such as electrical conduit or junction boxes, • Do not recess the SPAN panel beyond the door hinges. NOTE: The door may be configured to open front either direction. Ensure door may swing open to 90' per NEC 11 026(A)(2) SPAN 1-00800-xx Installation Manual (rev, 2022-05-30) 6 Accessories The following accessories may be used with SPAN Panels SPAN Main Lug Assembly SPAN PN: 1-01934-01 SPAN Flush Mount Trim Kit SPAN PN: 1-01046 SPAN Networking Kit (for MUlti-panel sites) SPAN PN: 1-00921 Set -vice enu ance barrier cover SquareD PN: PKSB I HA Top hub closing plate SquareD PN: ACPCP Top threaded conduit hub, rainproof SquareD A series hubs Filler plate for branch breaker knockouts SquareD PN: HOMFPCP Add -on Neutral / GND lugs (Field -installed) ILSCO NBST-2/0 SquareD HOM100AN GE TLK20 Add -on GND bar kit {Field -installed) UL Recognized ground pars may be installed by tapping threaded holes in the SPAN Panel enclosure, according to NEC requirements. Powerhne Ethernet Adapter Kit Recommended options: TP- Link AV1 000 TP-LinkAV600 SPAN 1-00800-xx Installation Manual (rev, 2022-05-30) 7 * Using a flat screwdriver, loosen the single deadft ont fastener screw and remove the deadfront cover. • Ensure the wall space can accommodate the flush section without Interference frorn pipes or conductors inside the wall space, • Using a drill and level, Mount the SPAN Panel enclosure on the wall, observing site and mechanical requirements, and applicable building codes. Secure the unit at all 4 mounting points. • When flush mounting, drill IW' pilot holes, marked by interior markings of the panel. Install fasteners through the side walls to secure the panel to the studs, as shown below. WARNING: Risk of electric shock. if you are replacing an existing electrical panel, make sure power is turned off before N7— removing the old panel and when Installing the SPAN Panel. Always make sure all electrical equipment is safely de- / Z (;% energized before beginning work CAUTION: The unit must be installed within 10 degrees of vertical, and level from side -to -side. SPAN 1-00800-xx Installation Manual (rev, 2022-05-30) 8 • The SPAN Panel allows conduit entry through the top, bottorn, lower sides, and rear section of the panel, • For top conduit entry, install a Squarel) A -series threaded hub, • Before removing knockouts. plan conduit routes and corresponding knockout locations and sizes on the enclosure. Be sure to allow adequate clearance for conduit routing and anchoring. Conduit installation must comply with applicable fill limits and electrical codes, 6,9" 3.25" 10,51, Panel Face 01 Panel Face t 1 0. 51, 3 25" Allowable Conduit Entry Locations (shown in blue) CAUTION: Do not punch conduit holes in any location on the enclosure that Would allow moisture to enter the unit. CAUTION: Follow guidance in NEC Chapter 3 and any local AN} requirements for cable type selection. Consider exterior sutface and flush mounted installations as wet/damp conditions and use conduit accordingly. When installed in wet/damp locations cable routed through the bottom face must be wet- or damp -rated, NOTE: Additional conduit holes can be punched in the top sections of the panel. Note the locations of antennas and wires inside the panel before cutting. Be careful Co keep metal shards frorn coming into contact with any energized pai ts, Use 0 appropriate fittings foi the location. NOTE: Use care when drilling and confirin that fittings are the correct size and NEMA rating for the installation location before proceeding. NOTE: When top conduit entry locations are not used for wire entry, it must be sealed properly with top hub closing plate. SPAN 1-00800-xx installation Manual (rev, 2022-05-30) Verify Neutral -to -Ground Bonding • When used as service equipment. ensure the factory -installed main bonding juniper is securely in piece, • When not Used as set -vice equipment, remove then air bonding jumper . WARNING: When the SPAN Panel is not installed as set -vice equipment, the factory -installed main bonding jurnper MUST be removed. in this case, ensure Neutral and Ground are properly bonded at the upstream service equipment, Oc N b 0' CAUTION: Do not modify or tewire at iy factory -instal led connections except the main bondingjurnper. NOTE: When the SPAN Panel is installed as set -vice equipment, ensure the panel's main breaker is appropriately labeled as "SERVICE / MAIN DISCONNECT' SPAN 1-00800-xx Installation Manual (rev, 2022-05-30) 10 • The SPAN Panel accepts a 100-200 A main breaker and up to 32 branch breakers in the pane! for load circuits, • Install each branch breaker by rocking it down to seat it fully onto the busbar stab and engaging the clips that hold it in position. Ensure each breaker is firmly in place, CAUTION: Install only listed and labeled circuit breakers compatible with the SPAN Panel, Branch circuits must not exceed the load limits specified below. General Use 90 A Full Load Inductive/Motor Amps 60 A Locked Rotor triductive/Motor Amps 270 A Breakers Listed for Use SPAN is multi -listed for use with 1-inch (2.54 cm) standard, tandem, AFCI, and GFCl branch CiFCUir breakers from SienienS/Wrrav, Eaton, and Squarel) types listed in table below. See Apltrf,,rm.h_x -A for complete details on breaker compatibility and short circuit rating. • SquareD type HOM, HOMT • Eaton type BR, BD, BQ • SiernenS/Wrray type QP, QT Squarel) QOM2 type: * 100AQOM2100VH 9 125 A QOM2125VH * 150 A QOM2150VH 0 175 A QOM2175VH # 200 A QOM2200VH * SPAN Panels manufactured with Serial Number (SN) xx-2223-xxxxx (middle 4 digits) and higher are not compatible with any plug -on neutral style branch circair breakers. When AFCIIGFCI branch breakers are required, a pigtail neutral breaker style must be installed with the neutral pigtail wire connected to the panel's neutral wiring terminal bar. CAUTION: Use only appropriately sized, compatible circuit breakers according to the type of load. Ensure breaker selection is in accordance with NEC, CEC, and local code articles for any field modifications. Additional or replacement breakers should be of the same manufacturer, type designation, and equal or greater interrupting rating - CAUTION: Refer to the specific breaker location instructions for each grid -forming hybrid Inverter in the Storage System Integration Manual. Hybrid inverter breaker(s) must be connected to the position(s) indicated for the system to operate as intended. SPAN 1 -00800-xx Installation Manual (rev, 2022-05-30) 11 Installing a Main Breaker The SPAN Panel rnust have either a main breaker installed (see above for compatible main breakers) or a SPAN Main Lug Assembly (PN: 1-01934-01). Main breakers and Main Lug Parts may be field installed according to this manual. To remove: To install: Remove the two (2) 11/12 fastening nuts using a 7/16-inch hex socket, Remove the fastening screw using a #2 Philips bit. Slide the main breaker or min lug kit downwards. Insert the main breaker or rnain Jug part as show below, Install the (1) Phillips #2 fastening screw, torquing to 31 in-lbs (3.5 N-m), Install the two (2) fastening nuts and washers. torquing to 45 in-lbs (5.1 N-m) using a 7/16-inch hex socket, ............ Fastener Torques for SPAN Main Lug Pan: 11 NOTE: Use a torque tool to avoid over -torquing the main breaker fasteners. I/ CAUTIOW Maximum current rating of the main breaker and main lug configuration is 200A. Bussing is rated to 225A. SPAN 1-00800-xx Installation Manual (rev. 2022-05-30) im Size all conductors with reference to the overcurrent protection device, arnpacity, and voltage drop requirements in accordance with all local electrical codes. Use conductors rated to minin-rurr-i of 75'C, • Connect supply-side Line 1 and Line 2 conductors to the main breaker terminals, • Connect Supply Neutral and Ground conductors to their respective tern-linal blocks. • Refer- to the table below for suitable conductor gauges and torque requirements. • SPAN sub -feed lugs are rated to 200A max. 'AC.x WARNING: Risk of electric shock. Check that all circuits are de -energized before wiring including generation equipment such as solar inverters and storage batteries. E61 6 ills" CAUTION: The SPAN Panel is only intended for use on 120/240 V split -phase electrical service. • Connect Line conductors for all circuits to the respective breaker. • Connect Neutral and Ground conductors to their respective wire terminals. • once all conductors are connected and secured, check that there are no exposed conductors or stray wit es. Clean up conductor routing to ensure no wires will be pinched when re -assembling the auicrtransformer cabinet and deadfi-ont assembly. NOTE: Keep track Of Circuit labelling. This information will be required during commissioning. SPAN 1-00800-xx Installation Manual (rev. 2022-05-30) 13 Terminal Wire Gauge, Strip Lengths, and Torque Values Ma4i Breaker See instructions on breaker SPAN Main Lug Part #6 - 250 kcrnfl 1.25 in (32 min) 3/8-in hex 250 (28.2) Main Neutral & Main GND tert-ninal #6 - 250 kanil 1.25 in (32 rrim) 3/8-in hex 250 (28,2) Larger Neutral terminals #11, - 1/0 0.75 in (20 nirn) 5 rnni 35 (4.0) for #14-10 slotted 40 (45 ) for #8 45 (51) for#G-4 50 (5,6) for #3-1/0 Smaller Neutral terminals & �14 - 4 0.5 in (12 rrim) 5111111 20 (23) for #14-10 GND tet niinal block slotted 25 (2.8) for #8 35 (4,0) for #6-4 Feed -through lugs (1-1/1-2) #6 - 250 kanil 1,25 in (32 rnrn) 5/16-in hex 250 - 275 (2U - 31.1) NOTE: Torque circuit breaker terminals to values specified on the breakers, aNOTE: Terininals integral to the Span panel are suitable lot- 60/75C AL/CU wire, Refer to circuit breaker inarkings for l !�breaker terniinals° temperature rating, A " ................................ . .. . ..... ..... ... SPAN 1-00800-xx Installation Manual (rev, 2022-05-30) 14 • Use mininium 300 V rated, shielded, twisted -pair, copper conductors only for communication wiring, • Connecting the SPAN Panel to the Internet with a wired Ethernet is strongly recommended. 031 NOTE: To insert wiring into R5485 terminal, use a 2mm flat head driver to depress the tab while inserting stripped wire. SPAN 1 -00900-xx installation Manual (rev. 2022-05-30) 15 To configure the door to open from the other direction: • Using a #2 Philips driver, remove the 2 hinge brackets and 2 latch brackets from the enclosure. • Re -install the hinge and latch brackets on the desired side, tightening each screw (2 per bracket) and torque to 26.5 in-lbs Nrn}, • On the inside of the door, remove and swap the mating hinge and latch hardware, and re -install and torque to 26.5 in-lbs (3 Nrn). J! P .M VI 1, µM+ SPAN 1.00800-xx Installation Manual (rev, 2022-05-30) 16 The Flush Mount Ts Kit (PN: 1-01046)iS Usedfor indoor installations to easily cover square holes cut into the wall during installation. The overall dimensions when mounted are 1123x405 mni (44.2,x 15,9 in), • Place the two (2) metal Trim Mounting Brackets directly against the SPAN Panel's top and bottom faces, USing the triangular decals to center. • Affix the upper and lower Trim Mounting Brackets to the wall or stud using four (4) mounting screws. • Snap the Trim Piece in place, ensuring all four mounting sockets ai e fully engaged. Installing Trim Mounting Brackets Snapping Trim Piece in Place SPAN 1-00800-xx Installation Manual (rev. 2022-05-30) 17 • Confirm that all connections are correct, properly grounded, and secure. • Replace the deadfront and securing using the flathead screw. • Install the door by sliding down onto the hinges. • Only after fully replacing the deadfront assembly, restore power. • Lock the panel closed with the hasp at the bottom of the panel door using a lock provided by the homeowner. WARNING: Risk of electric shock. Do not modify the deadfront other than to configure the door hinges of to t ernove or eplace bre aker- filler plates, as needed. IR r The Panel must be configured with the SPAN Installer App prior to use. Download the SPAN Installer App from Follow the on -screen instructions. When prompted to connect to the panel, refer to the panel Serial Number located on the prodUCt label inside of the door. 1i,it NOTE: When SPAN*s relays open/close they will sound like a digital camera taking a photo. When SPAN transitions on- or off -grid, several relays may open/close at once which sounds like a digital camera taking multiple photos. This is normal. SPAN Installer App home screen SPAN 1-00800-xx Installation Manual (rev. 2022-05-30) 18 For additional troubleshooting and support visit f;, T Follow these troubleshooting steps to establish communication and verify operation of the SPAN Installer App: • Wait at least 3 minutes after powering on before attempting to connect to the Panel, • Ensure the panel is connected to the inter net. using the Installer Apo. • Ensure the battery backup system is communicating with the SPAN Panel using the Installer App. • Ensure ail circuits and circuit locations are correctly identified in the Installer App. • To restart the system. press and hold the Reset button for 10 seconds (see "Resetting the System" below). For further assistance, contact support@span.io, WARNING: Do not attempt to open, disassemble, repair, tamper with, or modify the equipment. The equipment contains no user -serviceable parts other than field -installed breakers. Contact the installer who installed the equipment for any repairs. Only qualified electrical personnel should remove the deadfront panel. Status LEDs Main Power Om Green Solid Main PCBA powered Off Off No AC power to panel Fault: Hybrid inverter and/or Green Solid autotransfornier automatically Warning A disconnected from main bussing. Off Off Not nial operation Green Solid Grid voltage detected Grid Status Off Off Grid voltage not detected Green Solid Gateway PCBA powered Gateway Power OG Off Off No power to Gateway PCBA (Future Use) x (Future Use) Y SPAN 1.00800-xx Installation Manual (rev, 2022-05-30) 19 If it becomes necessary to restart the system use a small tool to press the Reset button, located below the communication terminals. Hold the button for 10 full seconds before releasing. If it is necessary to n-)anually reconnect your home to the grid, SPAN Support may direct You to operate the manual override in the SPAN Panel. • To reconnect to the acid manually, peel away the protective label, insert a large flathead screwdriver, and turn counterclockwise until vou hear a click, -' CAUTION: Do not remove the protective label or operate the manual override unless directed to do so by SPAN Support. Improper operation of the manual override may damage the unit, Branch circuit position numbers are labelled adjacent to the breaker. A specific space location can be associated with the physical circuit position in the SPAN panel by viewing the space in either the SPAN Installer or SPAN Horne app. To add, remove, or change branch circuit breakers: • Follow instructions above in this manual to select, install, and wire circuit breakers. • Use the SPAN Installer app to make changes to the branch breakers, following on screen instructions. Homeowners should be instructed to contact SPAN Support for any future branch breaker additions, removals, or changes, CAUTION: To perform routine service or maintenance on circuits, confirm that the cot -responding circuit breakers are switched off. Powering down circuits using the SPAN internal relays should not be considered a suitable off position for servicing equipment, SPAN 1-00800-xx Installation Manual (rev. 2022-05-30) 20 SPAN has been evaluated per the UL Standard for Panelboards; for use with the branch breaker types below in Table A.1. Informational notes: • National Electric Code (NFPA 70) does not prohibit the use of different branch circuit breakers in panelboards provided it does not violate the listing of any equipment. NEC article I I 0.3(B) states "Equipment that is listed, lobeied, or both shall be installed and used in accordance with any instructions included in the listing or labeling " • The standard for Molded -Case Circuit Breakers (UL 489) does not require listing circuit breakers for use in specific panel, not does this standard cover panelboat ds, Such testing is covered by the UL standard for Panelboards (UL 67), which does require the panelboai d to be listed with specific breaker- types. SPAN is certified to the UL 67 standard via a Nationally Recognized Testing Lab (NRTL) for use with the branch circuit breakers below. This is reflected in this Installation infon-nation as well as marked on the product itself. For additional Information visit , -- Table A.1 Series Specified Main Breaker Rating Specified Branch Breakers Amps Amp Manufacturer Catalog Manufacturer Ratings Numbers 22,000 100to200, SquareD QOM2125VH, Eator, QON12125VH, QW215OVI-1, Q03,1217SVH, Q0?V122OOVH munay SPAN 1-00800-xx Installation Manual (rev. 2022-05-30) Style Type I Poles Max Catalog Numbers Amp General SR 1,2 90 SR or BRH 'allowed by 110 to 1 290 Duplex f tandem) BD 1 50 BD followed by In 10 to S050 Quadplex ftanderril BQ and BQC 1,2 50 BQ 'allowed by 215215 to 2502120 Combination arc fault BR 1,2 20 SRN, BRC, or BRL fdlowed by circuit Interrupter 110 to 120; followed by AP or ,AFCI) CAP Ground fault circuit GF, CB and 1,2 60 SRN, GFTCB, BRHNI, or interrupter (GFCI) GFEP GPTCBH followed by 110 to Ground fault GFEP equipment p otecion Dual function BR comb'natron ground fault and arC-fadt protection General NIPJ Duplex ( tandem) MH-T Triplex (tandems MH-T Quadplex(tandem) MH-T Branch -feeder arc fault MIP-AT2 di cu;t interrupter Combination arc fault circuit intet rupter (AFC() Ground fault circuit %1P-GT 'Interrupter (GKI) 260; may be fog lowed by GF 1,2 SO SPIN or GFEP followed by ', I S to 250; may be follow ed by EP 1 20 BRN or BRAFGF followed by 110 to 120: may be followed by DF U 90 NIP or NVI-i fo4owed by 110 to 290: may be followed by KH 1 30 NIP followed by 1010 to 3030; may be followed by N 1,2 30 MP followed by 21010 to 25020 2 40 NIP followed by 2151S to 24040: followed by CT2 1,2 20 MPAfcillcwed by 115 to i 20� roilowed by AP: may be followed by H 1,2 20 MP or VIPA `allowed by 10 to 220; followed by AFC; may be followed by H 1,2 CO NIP followed by 110 to 260; followed by GFA: may be ,ollowed by H 21 Siemens Squai e D (Homeline)* 10,000 None me n/a All specified (Main Lug) -e , I manufacturers Dual function %IP-G combir atlo,,, gi ground fault and arc -fault p� O'ect Genet -at Qp Duplex (tandem) QT Triplex {tandem) QT Quadplex (tandem) QT Branch' -feeder arc fault QAF2 circult interrupter AT2 I Combination arc fault QAF and circuit interrupter Q*2 (AFCI) Tandem combination CAM arc -fault cii-cuit interrupter (AFCJ) Ground fault circuit QPF and interrupter (GFCI) QPF2 Ground fault QE equipment protection Dual function QFGA2 combination ground fault and arc -fault protection General HO.M Tandem (duplex) HOMT 1,2 1 1,2 2 1,2 l, 2 1 1,2 3,2 1 1,2 1 Quad (tandem) HOMT 1, 2 K Combination alc fault HOld-CAR 1,2 circuit interrupter (AFCI)- Gi-ound fault circuit HOM-GR 1,2 interrupter GrOUnd fault HOUNI-El"D 1,2 equipment protection ,Dual function HO%I-DF I combination ground fault and Is! c-I.-ult protection* 20 M P followed by 1, 10 to 220; followed by DF; may be followed by H 90 Q followed by 110 to 290; may be followed by H 30 Qf followed by 1010 to 3030 may be followed by NC 30 Q followed by 2 10 '1 0 to 23030; followed by CT 40 Q followed by 215115 to 24040; followed by CT2 20 Q4 followed by 1, 15 to 120; followed byAR may be followed by H 20 Q or QA followed by 110 to 220; followed by AFC: may be followed by H 20, Q followed by 11,010 to 2020,; 7ollowed by AFC 60 QP followed by 110 to 260; followed by A; may be `Oflowed by H 60 QE followed by 115 to 260; may be followed by H 20 Q followed by 11i 0 to 120� followed by DF; may be followed by H 90 HOM followed by 110 to 290 30 HOMT foflowed by 1010 to 3020 50 HOW followed by 1515215 to 2020250 50 HOMT followed by 215215 to 230250 jj 20 HOIxI folicoject by 111) to 220; followed by CAR 50 HOMfollowedby 110 to 25(,; followed by GR 50 ROM followed by 115 to 250; followed by EPD 20 HOM followed by 11 rj to 120; ;ollowed by DF All specified types SPAN Panels irancnIaCtUred with Serial Number (SN) Y.x-2.223-xx.xxx (middle 4 digits) and Nigher not compatible with plug -on neutral style branch circuit breakers, and pigtail neutral breaker styles must be 'Installed. SPAN Panels with Serial Number (SN) xx-2222-xxxxx (middle 4 digits) and lower are compatible with SquareD Horn.elme plug -or, neutral, as indicated by catalog numbers: • HOM follcrwed by I Ir, to 220; followed by P; foilovjed by CAR, • HOM followed by 110 to 250: followed by P: followed by GPL • HOM followed by I 1c) to 120; followed by P: followed by DF. SPAN 1-00800-xx Installation Manual (rev. 2022-05-30) 22 Per 2020 NEC 230.67 Surge Protection • A surge protective device (SPD) shall be installed in all new and replacement services supplying dwelling units, • Shall be Type I or Type 2 SPD. • Shall be attached to the service equipment or immediately adracent, Exception: The SPD shall not be required to be in the service equipment if located at each next level distribution equipment downstream towat d the load. SPAN is compatible with virtually any standard SPD connected to a 2-pole breaker or installed on a 2-space slot if) equivalent SdUareD HOM, Eaton BR, or Siemens/MUri ay QPIMP panelboat ds, • When installing an SPD, rnark it as an essential circuit in the SPAN Installer Apo under Advanced settings, depicted below. • If using an SPD with usable circuits, be sure to only have essential items on those circuits (e.g,, internet router, alarms, fire detection). Homeowners will not be able to turn this circuit off via the SPAN Horne app. .�J- ., -d Breakerl 2-pole (Breaker 3) Y 1-r,qd op Sow, ma" W=7 I SPAN 1 -00900-xx installation Manual (rev. 2022-05-30) 23 The SPAN Main Lug Assembly (SPAN PN: 1-01934-0) is designed and listed only for use in the SPAN Panel (PN 1-00200-xx, 1-00800- XX). Dimensions Weight Wire Type Wire Gauge Current Rating AC Voltage (nominal) Max Input Short Circuit Operating Temperature 4-7/8 x 5-1/8 x 2-1 /8 in (124 x 130 x 54 nini) 0.66 lbs (0.30 kg) Copper or AlurninUln (CU7AL) #6 - 250 kcrnif 200 A 120/240 VAC 10 kA -22 to 122cF (-30 to 50-C) 1. "0 NOTE: See Instafhng a Main Bi eaker" section above for complete installation steps, torques, etc. SPAN 1-00800-xx Installation ManUal (rev. 2022-05-30) 24 ZZEMM 2021-05-15 0 First revision 2021-06-04 • Corrected product weight in spec table • Added Networking Kit and Trim Kit to accessory list Added Servicing instructions regarding breaker replacement or additions 2021-06-21 • Added main breaker I eplacernent details • Added Flush Mount Trim Kit installation instructions 2021-06-29 • Added dimensions for Flush Mount Trim Kit 2021-12-04 0 Added Appendix A: Circuit Breaker Compatibility 2022-01-21 * Added Appendix B: Surge Protective Device Compatibility • Updated figure in Install Conduit section to include Conduit Entry Location dimensions • Updated Wiring the Panel section to include sub -feed JU.P rating 2022-01-28 0 Updated image and inforn-lancin under section "Dimensions, Clearances, and Access" • Minot- updates to "Preparing to Install" section 2022-04-19 * Updated breake4 compatibility list 2022-05-30 0 Updated format of Appendix A 0 Added information for Main Lug Kit (Appendix Q 2022-06-24 * Minor updates to Main Lug Part (Appendix C) and Installing a Main Breaker section 2022-08-30 • Minor updates installation recommendations SPAN 1 -00800-xx Installation Manual (rev. 2022-05- 30) 25 This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may Applicant: Span,10, Inc. Manufacturer: OnCore Manufacturing LLC dba NECK Tech Address: 679 Bryant St., Address: San Francisco CA 94597 Country: USA Country: Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Intertek Testing Services NA, Inc- Cortland. NY Control Number: 5017188 Authorized by: for L. Matthew Snyder, Certification Manager s T u� k4sytVT) Intertek 111MI I N11! 111RE1111 Will 0111 1 mmwm� This Authorization tot lark 12 for the exclusive use ofirdertek's Client and is provided pursuant to the Certification agreement petivemi Intertek and qs Client tirteriek s, cesporrsfbllitp and liabRilr are limited to the terr and conditions of dis, agreement Intertek assumes no NaUlity to an. party other than to the Client in accordance v.ith the agreement for an) loss expense or damage occasioned btu the use of this yeimonzation to Mark Croy the Client is authonzed to permit copying or distribution of thisAuthorizanon to Mark and then imij in its entirety, Use of inteftek s Cerbfication mark is restricted to the conditions laid out in the agreement and or IN Authorization to Ma* Anv further use of She fintrolek name for the sale or adveritsentemi of the tastedmalairat product or service must first be approved in orn:ng by Intertek W14 Factory A-sessmerus and Follow op Semces are for the purpose of assuring appropriate usage of the Certification mark in accordance tfth the agreement, they are not for the purpose of production quality control and do im,elieve the Client of his, obligations in this respect 11M- Wo MH Standard(s): Energy Management Equipment{Energy Monitoring Equipment)>Expires on: 22Ju[2022< [UL 916:2015 Ed,5] Product: Smart Panel Models: 1-00200- followed by 01 or 02 or 12: may be followed by RCS or ML or NX, 1-00800- may be followed by 00 to 99, ATM for Report 104174176CRT-001 Page 1 of 1 ATM Issued: 19-May-2022 ED 16 3 15,16-00-2021 . Mandatory