HomeMy WebLinkAboutSFRA2026-000433RECEIVED: 02/18/2026 DATE OF ISSUANCE:
26-000433
3081 HIGH MESA CT
GENERATOR (26KW) PERMIT #: 26-000433
BUILDING PERMIT APPLICATION ELECTRONIC REVIEW
(PLEASE PRINT LEGIBLY — COMPLETE ENTIRE FORM)
JOB ADDRESS: 3081 High Mesa Ct. Grapevine, Tx 76051
LOT: BLOCK: SUBDIVISION:
BUILDING CONTRACTOR (company name): NTX-Power
CURRENT MAILING ADDRESS: 1020 Bermes Ct.
CITY/STATE/ZIP: Brock, Tx 76087
PROPERTY OWNER: Jimmy Victory
CURRENT MAILING ADDRESS: 3081 High Mesa Ct
CITY/STATE/ZIP: Grapevine, Tx 76051
PROJECT VALUE: $15,197.21
SUITE #
PH: # 682-450-7478 Fax it
PHONE NUMBER: 817-247-1967
FIRE SPRINKLERED? YES NO X
WHAT TRADES WILL BE NEEDED? (Cheek ones that apply) ELECTRIC X PLUMBING X MECHANICAL_
DESCRIPTION OF WORK TO BE DONE: Installation of Kohler 26kW HSB Generator w/ 200amp ATS.
USE OF BUILDING OR STRUCTURE: N/A
NAME OF BUSINESS: NTX-Power
Total Square Footage under roof: 0 Square Footage of alteration/addition: 0
I hereby certify that plans have been reviewed and the building will be inspected by a certified energy code inspector in accordance with
State Law. Plan review and inspection documentation shall be made available to the Building Department (required for new buildings,
alterations and additions)
❑ 1 hereby certify that plans have been submitted to the Texas Department of Licensing and Regulation for Accessibility Review.
Control Number: (Not required for I & 2 family dwellings)
❑ I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas
Department of Health.
(REQUIRED FOR DEMOLITIONS, ADDITIONS AND OR ALTERATION TO COMMERCIAL AND PUBLIC BUILDINGS)
I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by
the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. It is understood that the issuance of
this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. I FURTHERMORE UNDERSTAND
THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY, AND THAT THE
DESIGN PROFESSIONAL/OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND
OR FEDERAL AGENCY(S).
PRINT NAME: Brandon Mitchell SIGNATURE
PHONE #: 682-450-7478 EMAIL:
® CHECK BOX IF PREFERRED TO BE CONTACTED BY E-MAIL
THE FOLLOWING IS TO BE COMPLETED BY THE BUILDING INSPECTION DEPARTMENT
Construction Type: Permit Valuation: $ Setbacks Approval to Issue
Occupancy Group: Fire Sprinkler: YES NO Front: Electrical V/
Division: Building Depth: Left: Plumbing vl�
Zoning: Building Width: Rear: Mechanical ---
Occupancy Load: Grease Trap Right: Hood
Plan Review Appro �� _ Date: a/�g/2� Building Permit Fee: 150.00
Site Plan Approva� Date:
Fire Department:
Public Works Department:
Health Department:
Approved for Permit:
Lot Drainage Submitted:
P.O. BOX 95104, GRAPEVINE, TX 76099 (817) 410-3165
Date:
Date:
Date:
Date:
Approved:
Plan Review Fee:
Lot Drainage Fee:
Sewer Availability Rate:
Water Availability Rate:
Total Fees:
Total Amount Due: 150.00
► fNN� • �1r`1,
O:FORMS\DSPERMITAPPLICATIONS 1/02-Rev.M04,5/ J�11/ /11,2J19
City of Grapevine
Building - Residential
GRAPEN, L E
PO Box95104
Alteration
--
_s
Grapevine, Texas 76099
`r
817) 410-3166
Project # 2"00433
Project Description: Installation of 26kW Home Standby
Generator & 200amp ATS. Installation to be connected from
Meter to ATS, ATS to customer breaker box. Fuel line to be
connected by rigid pipe, connectors, regulator, flex line and shut
off valve. IELECTRONiC REVIEWI
Issue,. — -- ,)2123/2026 at 10:28 AM
ADDRESS
INSPECTIONS
1
3081 High Mesa Ct.
Grapevine, TX 76051
1. Building Final
LEGAL
INFORMATION FIELDS
High Country Addition
`APPLICANT NAME (Individual)
Brandon Mitchell
Blk 4 Lot 4
S
**APPLICANT PHONE NUMBER
_
682-450-7478
APPLICANT E-MAIL
PERMIT HOLDER
Brandon Mitchell
VALUATION
15197
NTX-Power
* CONSTRUCTION TYPE
Home Standby Generator
(682) 450-7478
* OCCUPANCY GROUP
NIA
COLLABORATORS
DOCUMENTS - MISC 01 J. Victory Grapevine
BUILDING PERMIT
APPLICATION.pdf
• Brandon Mitchell
NTX-Power
DOCUMENTS - MISC 02 3081 High Mesa Ct. Packet.pdf
(682) 450-7478
APPROVED TO ISSUE ELECTRIC
YES
APPROVED TO ISSUE PLUMBING
YES
OWNERS
• Jimmy D Victory
FEE TOTAL
PAID DUE
Building Permit Fee, ($150.00 $ 150.00
$150.00 $150.00
Flat Fee) Simple Alteration
TOTALS $ 150.00
$150.00 $ 0.00
READ AND SIGN
I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF
MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO
THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN
COMPLIANCE WITH THE CITY OF GRAPEVINE ORDINANCE REGULATING
CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT
DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR
ORDINANCE OF THE CITY OF GRAPEVINE.
I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE
NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY AND THAT
THE DESIGN PROFESSIONAL / OWNER IS RESPONSIBLE FOR OBTAINING
Page 1/2
MYGOV.US 26-000433. 0212312026 at 10:28 AM Issued by: Courtney Cogburn
►i
3081 H)GH MESA
.39. 43
RECEIVED. 0118 2026
Z,OM3
HIGH MESA CT
GENERATOR 1,
CT) ��41E1-e-
I.C- }
BLOCK k
ALL CHANGES REQUI
APPROVAL OF REVIS
PLANS I
CbMACTOR SHALL CALL FOR INSPECTIONS:
(8171 4510-r�3v0�1�0a
CONTRACTOR REGISTHATION WILL BE
` =s REVOKED UPON PERMIi1-LOXISTRATION.
H
!B= N
,I u.
A Separate plumbing
and electrical permits
are required.
aTv oF� nA EVINE
THI S PAGE RELEASE W...RLW�.
-.�. .-.
5' 11TILTY ES"'T
RELEASEGOECNOT JTHORIZEANYWORN
IN CONED CTWITHT=BUILOINGCOOEOR
ZONING, I
I
f T'AW ly/6�/H ALL MES ON THE
TO BE
TI
ry/{ �{j5
1yy�yy
02/1812026 BY: LARRY GRAY
BUILDING INSPECTION DIVISION
RELEASEG DOES NOT APPLY TO
CONSTRUCTION IN EASEMENDS OR PUBLIC
RIGHT OF>VAY.
ALL CHANGES MUST BE APPROVED.
d�
17 _mare
Gen
KWIR, 264W Ph d 16' (ram resldmHal wall.
IT Iran E. fa 11125, kw S. f"" 111,11.
II I III
�Iar
}C?3 0
3081 HIGH MESA CT, �IrcZl��l�
N
89.43 �F
III
-----470---- .. ... sib•
LOT 4 r G
BLOCK
ti
Y! I PF
4
7 2GAR
(IHOUSE
1 STORY BRICK
15
SCALE 1".2D' �
18= Yt
u iL
0
A h.
N
Ot
c
8 c
<'
o
_
U
2
S
UTILTV ESM'T
PF
PLAT SHOWING
SURVEY OF
PREMISES LOCATED ON LOT 4, BLOCK 4, HIGH COUNTRY, PHASE II,
AN ADDITION TO THE CITY OF GRAPEVINE, TARRANT COUNTY, TEXAS, ACCORDING
TO PLAT RECORDED IN VOLUME_ 388-169, PAGE 7 & 8, PLAT RECORDS, TARRANT
COUNTY, TEXAS.
COMMONLY KNOWN AS 3081 HIGH MESA COURT
This is to certify that I have surveyed the
above described property and find buildings
wholly within the bounds of said property
and no encroachments thereon, except as shown.
ec
Registered Public Surveyor No. 2U14
�G►7 i�s I?µ. ..., �I.. ...
Date VV a `NALT"-R W. VIAP^
Resurveyed 4/28/87 "'" "f
According to the FIRM this lot is not
affected by the 100 year flood plane.
WARD COMP I
NO
COMPANY
P. O.BOX 10253
FORE WORTH, TEXAS 74119
PHONE •C 18171 241-5411 11
KOHLER,
09001
411301ILIM.
The Kohler® Advantage
High Quality Power
Home generators provide advanced voltage and frequency
regulation along with ultra law levels of harmonic distortion
for excellent generator power quality to protect your
valuable electronics.
Premium 5-yr/2000.hr Limited Warranty Included
Kohler Is known for extraordinary reliability and
performance. Kohlers premium limited warranty covers
parts, labor, and travel for the full warranty, period.
Powerful Performance
Exclusive Powerbeostok technology provides excellent
starting power. s
Aluminum Enclosure
o Attractive aluminum enclosure allows installation as
close as 18 inches from your home or small business. t
o Enclosure panels can he removed without tools to allow
easy access for maintenance and service.
Enclosure Options for single-phase units
o Kohler® Exclusive Colors are available. Go to
homeenergy.kohlemnergy.com to see the latest colors.
o Camouflage Enclosures are available for single-phase
units (optional). Go to homeenergy.kohlemnergy.com
/Mossyoak to view the available patterns
MossyOaken a traJemarku NUMmbcenee more Haas Oumoors, Inc., by KohlerCo.
Generator Ratings
Models: 26RCA(L)
Multi -Fuel
LPG/Natural Gas
Standard Features
• RDC2 Controller
o One digital controller manages both the generator set and
transfer switch functions (with optional Model RXT).
o Electronic speed control responds quickly to varying
demand.
o KOHLER Energy Management System for remote
monitoring is Included with the generator.
• Command PRO Engine Features
o Command PRO® OHV engine with hydraulic valve lifters
for reliable performance without routine valve adjustment
or lengthy break-in requirements.
• Designed for Easy Installation
o Sturdy aluminum base can he mounted on gravel or a
concrete mounting pad.
o Fuel and electrical connections through the enclosure wall
eliminate the need for stub -ups through the base.
o Customer connection terminal block located near the
controller allows easy access for field wiring.
o Designed for outdoor installation only.
• Certifications
o Meets emission regulations for U.S. Environmental
Protection Agency (EPA) with both natural gas and LPG.
o cULus listed.
o Accepted by the Massachusetts Board of Registration of
Plumbers and Gas Fitters.
o Meets 181 mph wind rating.
• Approved for stationary standby applications in locations
served by a reliable wilily source (on -grid).
• Exercise Modes
o EcoExerase, unloaded, with system diagnostics
(90 seconds). Reduces fuel costs and minimizes sound
disruption.
o Unloaded exercise with complete system diagnostics (20
minutes).
o Unloaded hillspeedexercise (20 minutes).
o Loaded full -speed exercise (20 minutes; Model RXT ATS
required)
o Weekly, bi-weekly, or new monthly exercise intervals.
• Model 26RCAL includes a model RXT automatic transfer
switch. See last page for more details.
standby Rafings, 60 Hz
Standby Ratings, W Hz
Natural Gas
LPG
Line Circuit
Natural
Gas
LPG
Line Circuit
kWl
kW/
Breaker
kWl
Wif
Breaker
Modelt
Alh.
P
Vo
Volts
WA A
WA
A
A P.J. [
Volts
WA
A
kVA
A
A Poles
26RCA/L
2F8
1
120240
24/24 1W
26/26
109
110 2
=30
18/18
78
18/18
78
W 2
3
12208
21/26 73
22/27
77
W 3
220/380
16/20
W
16/20
30
30 3
26RCA
2G8
3
120240
2V26 64
=7
67
W 3
23014W
16/W
29
161
29
W 3
3
277/480
21/26 32
=7
34
$0 3
2401416
1620
28
16/20
28
30 3
Non: Thelireawdbma
saulm cWlys cledbashon8egemeabcselmMelandvonagemmfigu2on.
—Without served by mreble amity mugs All slink phase unit are end air 10 powxc muse[ Tie snndby 24ng Is appfiaNe b vuude Ions wM
Consist Ko leek Pumv Systems pensaonal b caludan Who tied mstlmnal 8mvee ry9en
t Mcet NCrA gumellmes M 18 inch clearance to cvmbusuble manems.Check stake aM local mouth on minimum dGane eeguked(core a sWususe
34315 (26RC) 10cele
Alternator Specifications
Alternator Specifications
specifications
Afierni
Manufacturer
Kohler
Type
2-Pole, Rotating Reid
Leads, quantity
2F8
4
2G8
12
Voltage regulator
Digital
Insulation:
NEMA M131-1.66
Material
Class H
Temperature rise
130"C Standby
Bearingquantity, type
1, Seared
Couptirg
Direct
Amomxxxtrwindugs
Full
Voltage regulzlion,rofmdtcrlFbad
±1.0%
RMS
One-step load acceptance
100%of Ruling
Peak motor salting WA: C3 dip for
voltages be"
240 V, 1 ph, 21`8 (4lead)
39 (60 Hz) 27 (50 Hz)
2,10 or 480 V. 3 ph, 2G8 (12 lead)
63 (60 Hz) 50 (50 Hz)
Engine
Alternator Features
• Compliance with NEMA, IEEE, and ANSI standards for
temperature rise.
• Selfventilatedand dripproof constructon.
• Windings are vacuum -impregnated with epoxy varnish for
dependability and long life.
• Superior voltage waveform and minimum harmonic
distortion from skewed alternator construction.
• Digital voltage regulator with 11. WA no-load to full -load
RMS regulation.
• Rotating field alternator with static exciter for excellent
load response.
• Total harmonic distortion (THD) from no load to full load
with a linear load is less than 5%.
Application Data
Engine specifications
50 Hz W Hz
Manufacturer
Kohler
Engine: model, type
CH10064Cycle
Cylinder arrangement
V-2
Displacement cm' (cu. in.)
999 (61)
Bore and stroke, min (in.)
W x 78.5 (3.54 x 3.1)
Compression ratio
10.5.1
More bearings: quamrty, type
2, Heavy -Duty Sleeve
Beanngs
Rated RPM
3" 3"
Max. engmo power at rated RPM, kW (HP)
LPG
26.1(36.4) 22.7 (30.4)
Natural gas
24.5 (33.0) 19.5 (26.2)
Cylinder head motional
Aluminum
Valve materal
SteeVStellite•
Piston type mind material
Aluminum Alloy
Cmmn l dt material
Heat Treated, Ductile Iron
Governor: type
Electronic
Frequency regulation, no load to full load IsoOrmnous
Frequency regulation, steadystate
±05%
Air leaner type
Dry
Engine Electrical
Engine Electrical system
Ignition system
Electronic,
Cmp.rove Discharge
Starter motor rated voltage (Dq
12
Battery (purchased separately)'
Ground
Negative
Vok,(DC)
12
Battery quantity
I
Recommended cold cranking
amps:
(CCA) rating for -18"C pFF)
500
Group size
51
Exhaust
Exhaust system
Exhaust temperature exiling the
enclosure a rated kW, dry, "C (T)
2W (500)
Lubrication
Lubricating system
Type
Full Pressure
Oil capacity, (w1h fitter), L (rp) §
1.9 (2.0)
Oil filtor. quantity, type §
1, Czdndge
Oil cooler
Integral
§ Kohler recommends the use of Kohler Genuine oil and fitters.
Fuel Requirements
Fuel System
Fuel types
Normal Gas or LPG
Fuel supply inlet
N4 NPT
Fuel supply pressure, Wa (in. H20):
Natural gas
0.9-2.7 P.5-11)
LP
1.7-2.7 (1-11)
Fuel Composition Limits •
Nat Cram LPG
Methane, % by volume (minimum)
90 min —
EEthani to by volume (maximum)
4.0 max. —
Prepare. %by volume
1.0 max. 85 min.
Propene, %by volume (maximum)
0.1 max. 5.0 max.
C. mind higher, %by volume
0.3 max. 2.5 max
Sultur, ppm mass (maxmum)
25 max
Louver heating value,
Wle (BIWfP), (minimum)
33.2 (890) 84.2 (2260)
' Contact your local dealer for suitability
and razing demons based
on Fuel compositions outside these limbs.
G4315 (26RCA) 11U24e
Fuel Pipe Size
Operation Requirements
Minimum Gas Pipe Size Rxmnmendation, in. NPr
Pipe Length,
Natural Gas
LPG
m(R.)
290,000 mallb,
322,500 Brute.
8 (25)
1
3/4
15 (50)
11/4
1
W (100)
1114
1
46 (150)
1 V4
1
61 (200)
1 V2
1114
Generator Set Sound Data
Model 26RCA sound levels are 56 dB(A) during engine
exercise and 67 dB(A) during full -speed generator
diagnostics and normal operation. -
All sound levels are measured at a distance of 23 g. (7 m)
from the generator set.
' Lavestof 8 poims measured around the generator. Sound levels
at other poirM around generator may vary depending on
installation parameters.
FuN Consumption, m3fhr. (cih) @ MHz
%Load
Natural Gas
LPG
100
8.2 (290)
3.6
(129)
75
6.7 (238)
3.1
(111)
50
51 (180)
2.4
(85)
25
39 (137)
1.8
(64)
Fxerase
1.9 (67)
0.9
(31)
Fuel Consumption, m3fhr. (cth) @ MHz
%Load
Natural Gas
LPG
100
6.9 (245)
2.9
(102)
75
6.2 (220)
2.5
(89)
50
54 (19M
1.8
(65)
25
37 (131)
1.3
(46)
Fxerase
1.9 (67)
0.9
(31)
amlm NeioA
a..iaz_ ow.1n=(art BNm.=)
LPG in whn=U. BWm=)
LPG con —Mt M
858 n==31b
RDC2 Controller Features
o;(F) lei
The RDC2 controller provides integrated control for the
generator set, Kohler' Model RXT transfer switch,
programmable interface module (PIM), and load shed kit
• Membrane keypad:
o OFF, AUTO, and RUN pushbuttons
o Select and arrow buttons for access to system
configuration and adjustment menus
• LED indicators for OFF, AUTO, and RUN modes
• LED indicators for utility power and generator set source
availability and ATS position (Model RXT transfer switch
required)
• LCD display:
o Two lines x 16 characters per line
o Backlit display with adjustable contrast for excellent
visibility in all lighting conditions
• Scrolling system status display:
o Generator set status
o Voltage and frequency
o Engine temperature
o Oil pressure
o Battery voltage
a Engine runtime boors
• Date and time displays
• Smart engine cooldown senses engine temperature
• Digital isochronous governor maintains steady-state
speed at all loads
• Digital voltage regulation: ±1.0°A RMS no-load to full -load
• Automatic start with programmed cranking cycle
• Built-in 2.5 amp battery charger
• Programmable exerciser can he set to start automatically
on any future day and time
0535 m== IN
.xri L1 s
• Exercise modes.
o New 90-second Eco Exercise with complete system
diagnostics (factory default setting)
o Lowers fuel cost
o Minimizes sound disruption
o In cold temperatures, limits condensation build-up
in the crankcase
o Unloaded 20-minute exercise with complete system
diagnostics
o Unloaded 20-minute full -speed exercise
o Loaded 20-minute hillspeedexercise (Model RXT
ATS required)
• Weekly, bi-weekly, or new monthly exercise intervals
• Frontaccessmini USB connector for SiteTech- or USB
Utildy connection
• Integral Ethernet connector for Kohler Energy
Management
• Remote two-vnre stardstop capability for optionai
connection of a Model RDT transfer switch
• Diagnostic messages: Displays diagnostic messages for
the engine, generator, Model RXT transfer switch,
programmable interface module (PIM), and load
management device.
• Maintenance reminders
• System settings:
o System voltage, frequency, and phase
o Voltage adjustment
o Measurement system, English, or metric
• ATS status (Model RXT ATS required):
o Source availability
o ATS position (normal utility or emergency/generator)
o Source voltage and frequency
• ATS control (Model RXT ATS required):
o Source voltage and frequency settings
o Engine start time delay
o Transfer time delays
o Voltage calibration
o Fixed pickup and dropout settings
• Programmable Interface Module (PIM) status displays'
o Input status (active/inactive)
o Output status (activelinactive)
• Load control menus:
o Load status
o Test function
G4-315 (26RCA) 10/24e
KOHLER.
Generator Set Standard Features
• Aluminum sound enclosure (cashmere color standard)
• Battery cables
• Critical silencer
• EPA certified fuel system
• Field -connection terminal block
• Fuel solenoid valve and secondary regulator
• Line circuit breaker
• Multi -fuel system, LPG/naturalypts, field�onvertible
• Oil drain extension with shutoff valve
• Oil level sensor
• Oil pressure sensor
• KOHLER Energy Management System
• Premium 5-year/2000 hour limited standby warranty.
Covers parts, labor, and travel for the entire warranty period
• RDC2 generator setIATS controller
• Rodentresistantconstruction
• Sound -deadening, flame-retardant foam per UL 94,
class HE
Available Options
Concrete Mounting Pads
❑ Concrete mounting pad, 3 in. thick
❑ Concrete mounting pad, 4 in. thick
(recommended for storm -prone areas)
Electrical Accessories
❑ Battery
❑ Battery heater, 120 VAC'
❑ Carburetor heater, 120 VAC t
❑ Cold weather kit, 120 VAC tt
o Includes oil and Heather tube heaters fuel regulator heater, and
pressure sensor cover
o QS model with factory-insUled kR is available (excludes fuel
regulator heater)
❑ Emergency stop kit
❑ Programmable interface module (PIM)
(provides 2 digital inputs and 6 relay corrals)
' eadery beater is recommendetl below -17"C (0"F).
$ Do not use a carburetor heater with a cold weather kit
t Cold weather kit is recommended] below 0"C (32"F).
Enclosure Options (single-phase only)
❑ Kohler' Exclusive Colors
Go to homeenergy.kohlemnergy.com to see the latest
colors.
❑ Mossy Oak® camouflage enclosures
Go to homeenergy.kohlemnergy.com/Mossyoak to see
available patterns.
Musty Oak m abademazkused uncerocense onto Haaz ONdcme, Inc., by omierCo.
Fuel System Accessories
❑ Flexible fuel line (included on QS models)
Discovery Energy, LLC
200 Twin Oaks Road, Kohler, WI 53044 USA
For the nearest sales and service outlet in
the US and Canada, phone 1-800-SM-24
KOHLEREnergy, rom
Literature
❑ General maintenance literature kit
❑ Overhaul literature kit
❑ Production literature kit
Maintenance
❑ Maintenance kit (includes air fiber, oil, oil filter, and
spark plugs)
❑ Premium 300 hour/2 year oil for fewer oil changes
Automatic Transfer Switches and Accessories
❑ Model ROT ATS
❑ Model RXT ATS with combined interfaceFload
management board
❑ Load shed kit for RXT or RUT
❑ Power relay modules (use up to 4 relay modules for
each load management device)
26RCAL Model Package
❑ 26RCAL with 200 amp service entrance -rated Model
RXT with combined interface/load management board
and carroson-resistant NEMA 3R aluminum enclosure
Warranty
❑ 7-Year Limited Warranty
❑ 10-Year Limbed Warranty
Warranties rover pans, labor, and travel for the entire
warranty period.
Generator Set Dimensions and Weights
Generator Set Size, L x W x H: 1193 x 660 x 620 tom
(47 x 26.0 x 32.3 in.)
Skipping Weights:
26RCA Generator Set: 20 kg (625lb)
26RCAL with 200 A RXT SE ATS: 304 IN; (670lb.)
L
NOTE Dim-nmons are moomed be reverence only and should not be used for planning
lnslarafkn. Conlacf your mal dealer for more denoted aomiadm_
DISTRIBUTED BY:
® N12<-O '—' Eneryy. LLC-All dgk6 enseon/ed
G4315 (261mCA) 10cole