Loading...
HomeMy WebLinkAboutSFRA2026-000433RECEIVED: 02/18/2026 DATE OF ISSUANCE: 26-000433 3081 HIGH MESA CT GENERATOR (26KW) PERMIT #: 26-000433 BUILDING PERMIT APPLICATION ELECTRONIC REVIEW (PLEASE PRINT LEGIBLY — COMPLETE ENTIRE FORM) JOB ADDRESS: 3081 High Mesa Ct. Grapevine, Tx 76051 LOT: BLOCK: SUBDIVISION: BUILDING CONTRACTOR (company name): NTX-Power CURRENT MAILING ADDRESS: 1020 Bermes Ct. CITY/STATE/ZIP: Brock, Tx 76087 PROPERTY OWNER: Jimmy Victory CURRENT MAILING ADDRESS: 3081 High Mesa Ct CITY/STATE/ZIP: Grapevine, Tx 76051 PROJECT VALUE: $15,197.21 SUITE # PH: # 682-450-7478 Fax it PHONE NUMBER: 817-247-1967 FIRE SPRINKLERED? YES NO X WHAT TRADES WILL BE NEEDED? (Cheek ones that apply) ELECTRIC X PLUMBING X MECHANICAL_ DESCRIPTION OF WORK TO BE DONE: Installation of Kohler 26kW HSB Generator w/ 200amp ATS. USE OF BUILDING OR STRUCTURE: N/A NAME OF BUSINESS: NTX-Power Total Square Footage under roof: 0 Square Footage of alteration/addition: 0 I hereby certify that plans have been reviewed and the building will be inspected by a certified energy code inspector in accordance with State Law. Plan review and inspection documentation shall be made available to the Building Department (required for new buildings, alterations and additions) ❑ 1 hereby certify that plans have been submitted to the Texas Department of Licensing and Regulation for Accessibility Review. Control Number: (Not required for I & 2 family dwellings) ❑ I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas Department of Health. (REQUIRED FOR DEMOLITIONS, ADDITIONS AND OR ALTERATION TO COMMERCIAL AND PUBLIC BUILDINGS) I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. It is understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY, AND THAT THE DESIGN PROFESSIONAL/OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR FEDERAL AGENCY(S). PRINT NAME: Brandon Mitchell SIGNATURE PHONE #: 682-450-7478 EMAIL: ® CHECK BOX IF PREFERRED TO BE CONTACTED BY E-MAIL THE FOLLOWING IS TO BE COMPLETED BY THE BUILDING INSPECTION DEPARTMENT Construction Type: Permit Valuation: $ Setbacks Approval to Issue Occupancy Group: Fire Sprinkler: YES NO Front: Electrical V/ Division: Building Depth: Left: Plumbing vl� Zoning: Building Width: Rear: Mechanical --- Occupancy Load: Grease Trap Right: Hood Plan Review Appro �� _ Date: a/�g/2� Building Permit Fee: 150.00 Site Plan Approva� Date: Fire Department: Public Works Department: Health Department: Approved for Permit: Lot Drainage Submitted: P.O. BOX 95104, GRAPEVINE, TX 76099 (817) 410-3165 Date: Date: Date: Date: Approved: Plan Review Fee: Lot Drainage Fee: Sewer Availability Rate: Water Availability Rate: Total Fees: Total Amount Due: 150.00 ► fNN� • �1r`1, O:FORMS\DSPERMITAPPLICATIONS 1/02-Rev.M04,5/ J�11/ /11,2J19 City of Grapevine Building - Residential GRAPEN, L E PO Box95104 Alteration -- _s Grapevine, Texas 76099 `r 817) 410-3166 Project # 2"00433 Project Description: Installation of 26kW Home Standby Generator & 200amp ATS. Installation to be connected from Meter to ATS, ATS to customer breaker box. Fuel line to be connected by rigid pipe, connectors, regulator, flex line and shut off valve. IELECTRONiC REVIEWI Issue,. — -- ,)2123/2026 at 10:28 AM ADDRESS INSPECTIONS 1 3081 High Mesa Ct. Grapevine, TX 76051 1. Building Final LEGAL INFORMATION FIELDS High Country Addition `APPLICANT NAME (Individual) Brandon Mitchell Blk 4 Lot 4 S **APPLICANT PHONE NUMBER _ 682-450-7478 APPLICANT E-MAIL PERMIT HOLDER Brandon Mitchell VALUATION 15197 NTX-Power * CONSTRUCTION TYPE Home Standby Generator (682) 450-7478 * OCCUPANCY GROUP NIA COLLABORATORS DOCUMENTS - MISC 01 J. Victory Grapevine BUILDING PERMIT APPLICATION.pdf • Brandon Mitchell NTX-Power DOCUMENTS - MISC 02 3081 High Mesa Ct. Packet.pdf (682) 450-7478 APPROVED TO ISSUE ELECTRIC YES APPROVED TO ISSUE PLUMBING YES OWNERS • Jimmy D Victory FEE TOTAL PAID DUE Building Permit Fee, ($150.00 $ 150.00 $150.00 $150.00 Flat Fee) Simple Alteration TOTALS $ 150.00 $150.00 $ 0.00 READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE ORDINANCE REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY AND THAT THE DESIGN PROFESSIONAL / OWNER IS RESPONSIBLE FOR OBTAINING Page 1/2 MYGOV.US 26-000433. 0212312026 at 10:28 AM Issued by: Courtney Cogburn ►i 3081 H)GH MESA .39. 43 RECEIVED. 0118 2026 Z,OM3 HIGH MESA CT GENERATOR 1, CT) ��41E1-e- I.C- } BLOCK k ALL CHANGES REQUI APPROVAL OF REVIS PLANS I CbMACTOR SHALL CALL FOR INSPECTIONS: (8171 4510-r�3v0�1�0a CONTRACTOR REGISTHATION WILL BE ` =s REVOKED UPON PERMIi1-LOXISTRATION. H !B= N ,I u. A Separate plumbing and electrical permits are required. aTv oF� nA EVINE THI S PAGE RELEASE W...RLW�. -.�. .-. 5' 11TILTY ES"'T RELEASEGOECNOT JTHORIZEANYWORN IN CONED CTWITHT=BUILOINGCOOEOR ZONING, I I f T'AW ly/6�/H ALL MES ON THE TO BE TI ry/{ �{j5 1yy�yy 02/1812026 BY: LARRY GRAY BUILDING INSPECTION DIVISION RELEASEG DOES NOT APPLY TO CONSTRUCTION IN EASEMENDS OR PUBLIC RIGHT OF>VAY. ALL CHANGES MUST BE APPROVED. d� 17 _mare Gen KWIR, 264W Ph d 16' (ram resldmHal wall. IT Iran E. fa 11125, kw S. f"" 111,11. II I III �Iar }C?3 0 3081 HIGH MESA CT, �IrcZl��l� N 89.43 �F III -----470---- .. ... sib• LOT 4 r G BLOCK ti Y! I PF 4 7 2GAR (IHOUSE 1 STORY BRICK 15 SCALE 1".2D' � 18= Yt u iL 0 A h. N Ot c 8 c <' o _ U 2 S UTILTV ESM'T PF PLAT SHOWING SURVEY OF PREMISES LOCATED ON LOT 4, BLOCK 4, HIGH COUNTRY, PHASE II, AN ADDITION TO THE CITY OF GRAPEVINE, TARRANT COUNTY, TEXAS, ACCORDING TO PLAT RECORDED IN VOLUME_ 388-169, PAGE 7 & 8, PLAT RECORDS, TARRANT COUNTY, TEXAS. COMMONLY KNOWN AS 3081 HIGH MESA COURT This is to certify that I have surveyed the above described property and find buildings wholly within the bounds of said property and no encroachments thereon, except as shown. ec Registered Public Surveyor No. 2U14 �G►7 i�s I?µ. ..., �I.. ... Date VV a `NALT"-R W. VIAP^ Resurveyed 4/28/87 "'" "f According to the FIRM this lot is not affected by the 100 year flood plane. WARD COMP I NO COMPANY P. O.BOX 10253 FORE WORTH, TEXAS 74119 PHONE •C 18171 241-5411 11 KOHLER, 09001 411301ILIM. The Kohler® Advantage High Quality Power Home generators provide advanced voltage and frequency regulation along with ultra law levels of harmonic distortion for excellent generator power quality to protect your valuable electronics. Premium 5-yr/2000.hr Limited Warranty Included Kohler Is known for extraordinary reliability and performance. Kohlers premium limited warranty covers parts, labor, and travel for the full warranty, period. Powerful Performance Exclusive Powerbeostok technology provides excellent starting power. s Aluminum Enclosure o Attractive aluminum enclosure allows installation as close as 18 inches from your home or small business. t o Enclosure panels can he removed without tools to allow easy access for maintenance and service. Enclosure Options for single-phase units o Kohler® Exclusive Colors are available. Go to homeenergy.kohlemnergy.com to see the latest colors. o Camouflage Enclosures are available for single-phase units (optional). Go to homeenergy.kohlemnergy.com /Mossyoak to view the available patterns MossyOaken a traJemarku NUMmbcenee more Haas Oumoors, Inc., by KohlerCo. Generator Ratings Models: 26RCA(L) Multi -Fuel LPG/Natural Gas Standard Features • RDC2 Controller o One digital controller manages both the generator set and transfer switch functions (with optional Model RXT). o Electronic speed control responds quickly to varying demand. o KOHLER Energy Management System for remote monitoring is Included with the generator. • Command PRO Engine Features o Command PRO® OHV engine with hydraulic valve lifters for reliable performance without routine valve adjustment or lengthy break-in requirements. • Designed for Easy Installation o Sturdy aluminum base can he mounted on gravel or a concrete mounting pad. o Fuel and electrical connections through the enclosure wall eliminate the need for stub -ups through the base. o Customer connection terminal block located near the controller allows easy access for field wiring. o Designed for outdoor installation only. • Certifications o Meets emission regulations for U.S. Environmental Protection Agency (EPA) with both natural gas and LPG. o cULus listed. o Accepted by the Massachusetts Board of Registration of Plumbers and Gas Fitters. o Meets 181 mph wind rating. • Approved for stationary standby applications in locations served by a reliable wilily source (on -grid). • Exercise Modes o EcoExerase, unloaded, with system diagnostics (90 seconds). Reduces fuel costs and minimizes sound disruption. o Unloaded exercise with complete system diagnostics (20 minutes). o Unloaded hillspeedexercise (20 minutes). o Loaded full -speed exercise (20 minutes; Model RXT ATS required) o Weekly, bi-weekly, or new monthly exercise intervals. • Model 26RCAL includes a model RXT automatic transfer switch. See last page for more details. standby Rafings, 60 Hz Standby Ratings, W Hz Natural Gas LPG Line Circuit Natural Gas LPG Line Circuit kWl kW/ Breaker kWl Wif Breaker Modelt Alh. P Vo Volts WA A WA A A P.J. [ Volts WA A kVA A A Poles 26RCA/L 2F8 1 120240 24/24 1W 26/26 109 110 2 =30 18/18 78 18/18 78 W 2 3 12208 21/26 73 22/27 77 W 3 220/380 16/20 W 16/20 30 30 3 26RCA 2G8 3 120240 2V26 64 =7 67 W 3 23014W 16/W 29 161 29 W 3 3 277/480 21/26 32 =7 34 $0 3 2401416 1620 28 16/20 28 30 3 Non: Thelireawdbma saulm cWlys cledbashon8egemeabcselmMelandvonagemmfigu2on. —Without served by mreble amity mugs All slink phase unit are end air 10 powxc muse[ Tie snndby 24ng Is appfiaNe b vuude Ions wM Consist Ko leek Pumv Systems pensaonal b caludan Who tied mstlmnal 8mvee ry9en t Mcet NCrA gumellmes M 18 inch clearance to cvmbusuble manems.Check stake aM local mouth on minimum dGane eeguked(core a sWususe 34315 (26RC) 10cele Alternator Specifications Alternator Specifications specifications Afierni Manufacturer Kohler Type 2-Pole, Rotating Reid Leads, quantity 2F8 4 2G8 12 Voltage regulator Digital Insulation: NEMA M131-1.66 Material Class H Temperature rise 130"C Standby Bearingquantity, type 1, Seared Couptirg Direct Amomxxxtrwindugs Full Voltage regulzlion,rofmdtcrlFbad ±1.0% RMS One-step load acceptance 100%of Ruling Peak motor salting WA: C3 dip for voltages be" 240 V, 1 ph, 21`8 (4lead) 39 (60 Hz) 27 (50 Hz) 2,10 or 480 V. 3 ph, 2G8 (12 lead) 63 (60 Hz) 50 (50 Hz) Engine Alternator Features • Compliance with NEMA, IEEE, and ANSI standards for temperature rise. • Selfventilatedand dripproof constructon. • Windings are vacuum -impregnated with epoxy varnish for dependability and long life. • Superior voltage waveform and minimum harmonic distortion from skewed alternator construction. • Digital voltage regulator with 11. WA no-load to full -load RMS regulation. • Rotating field alternator with static exciter for excellent load response. • Total harmonic distortion (THD) from no load to full load with a linear load is less than 5%. Application Data Engine specifications 50 Hz W Hz Manufacturer Kohler Engine: model, type CH10064Cycle Cylinder arrangement V-2 Displacement cm' (cu. in.) 999 (61) Bore and stroke, min (in.) W x 78.5 (3.54 x 3.1) Compression ratio 10.5.1 More bearings: quamrty, type 2, Heavy -Duty Sleeve Beanngs Rated RPM 3" 3" Max. engmo power at rated RPM, kW (HP) LPG 26.1(36.4) 22.7 (30.4) Natural gas 24.5 (33.0) 19.5 (26.2) Cylinder head motional Aluminum Valve materal SteeVStellite• Piston type mind material Aluminum Alloy Cmmn l dt material Heat Treated, Ductile Iron Governor: type Electronic Frequency regulation, no load to full load IsoOrmnous Frequency regulation, steadystate ±05% Air leaner type Dry Engine Electrical Engine Electrical system Ignition system Electronic, Cmp.rove Discharge Starter motor rated voltage (Dq 12 Battery (purchased separately)' Ground Negative Vok,(DC) 12 Battery quantity I Recommended cold cranking amps: (CCA) rating for -18"C pFF) 500 Group size 51 Exhaust Exhaust system Exhaust temperature exiling the enclosure a rated kW, dry, "C (T) 2W (500) Lubrication Lubricating system Type Full Pressure Oil capacity, (w1h fitter), L (rp) § 1.9 (2.0) Oil filtor. quantity, type § 1, Czdndge Oil cooler Integral § Kohler recommends the use of Kohler Genuine oil and fitters. Fuel Requirements Fuel System Fuel types Normal Gas or LPG Fuel supply inlet N4 NPT Fuel supply pressure, Wa (in. H20): Natural gas 0.9-2.7 P.5-11) LP 1.7-2.7 (1-11) Fuel Composition Limits • Nat Cram LPG Methane, % by volume (minimum) 90 min — EEthani to by volume (maximum) 4.0 max. — Prepare. %by volume 1.0 max. 85 min. Propene, %by volume (maximum) 0.1 max. 5.0 max. C. mind higher, %by volume 0.3 max. 2.5 max Sultur, ppm mass (maxmum) 25 max Louver heating value, Wle (BIWfP), (minimum) 33.2 (890) 84.2 (2260) ' Contact your local dealer for suitability and razing demons based on Fuel compositions outside these limbs. G4315 (26RCA) 11U24e Fuel Pipe Size Operation Requirements Minimum Gas Pipe Size Rxmnmendation, in. NPr Pipe Length, Natural Gas LPG m(R.) 290,000 mallb, 322,500 Brute. 8 (25) 1 3/4 15 (50) 11/4 1 W (100) 1114 1 46 (150) 1 V4 1 61 (200) 1 V2 1114 Generator Set Sound Data Model 26RCA sound levels are 56 dB(A) during engine exercise and 67 dB(A) during full -speed generator diagnostics and normal operation. - All sound levels are measured at a distance of 23 g. (7 m) from the generator set. ' Lavestof 8 poims measured around the generator. Sound levels at other poirM around generator may vary depending on installation parameters. FuN Consumption, m3fhr. (cih) @ MHz %Load Natural Gas LPG 100 8.2 (290) 3.6 (129) 75 6.7 (238) 3.1 (111) 50 51 (180) 2.4 (85) 25 39 (137) 1.8 (64) Fxerase 1.9 (67) 0.9 (31) Fuel Consumption, m3fhr. (cth) @ MHz %Load Natural Gas LPG 100 6.9 (245) 2.9 (102) 75 6.2 (220) 2.5 (89) 50 54 (19M 1.8 (65) 25 37 (131) 1.3 (46) Fxerase 1.9 (67) 0.9 (31) amlm NeioA a..iaz_ ow.1n=(art BNm.=) LPG in whn=U. BWm=) LPG con —Mt M 858 n==31b RDC2 Controller Features o;(F) lei The RDC2 controller provides integrated control for the generator set, Kohler' Model RXT transfer switch, programmable interface module (PIM), and load shed kit • Membrane keypad: o OFF, AUTO, and RUN pushbuttons o Select and arrow buttons for access to system configuration and adjustment menus • LED indicators for OFF, AUTO, and RUN modes • LED indicators for utility power and generator set source availability and ATS position (Model RXT transfer switch required) • LCD display: o Two lines x 16 characters per line o Backlit display with adjustable contrast for excellent visibility in all lighting conditions • Scrolling system status display: o Generator set status o Voltage and frequency o Engine temperature o Oil pressure o Battery voltage a Engine runtime boors • Date and time displays • Smart engine cooldown senses engine temperature • Digital isochronous governor maintains steady-state speed at all loads • Digital voltage regulation: ±1.0°A RMS no-load to full -load • Automatic start with programmed cranking cycle • Built-in 2.5 amp battery charger • Programmable exerciser can he set to start automatically on any future day and time 0535 m== IN .xri L1 s • Exercise modes. o New 90-second Eco Exercise with complete system diagnostics (factory default setting) o Lowers fuel cost o Minimizes sound disruption o In cold temperatures, limits condensation build-up in the crankcase o Unloaded 20-minute exercise with complete system diagnostics o Unloaded 20-minute full -speed exercise o Loaded 20-minute hillspeedexercise (Model RXT ATS required) • Weekly, bi-weekly, or new monthly exercise intervals • Frontaccessmini USB connector for SiteTech- or USB Utildy connection • Integral Ethernet connector for Kohler Energy Management • Remote two-vnre stardstop capability for optionai connection of a Model RDT transfer switch • Diagnostic messages: Displays diagnostic messages for the engine, generator, Model RXT transfer switch, programmable interface module (PIM), and load management device. • Maintenance reminders • System settings: o System voltage, frequency, and phase o Voltage adjustment o Measurement system, English, or metric • ATS status (Model RXT ATS required): o Source availability o ATS position (normal utility or emergency/generator) o Source voltage and frequency • ATS control (Model RXT ATS required): o Source voltage and frequency settings o Engine start time delay o Transfer time delays o Voltage calibration o Fixed pickup and dropout settings • Programmable Interface Module (PIM) status displays' o Input status (active/inactive) o Output status (activelinactive) • Load control menus: o Load status o Test function G4-315 (26RCA) 10/24e KOHLER. Generator Set Standard Features • Aluminum sound enclosure (cashmere color standard) • Battery cables • Critical silencer • EPA certified fuel system • Field -connection terminal block • Fuel solenoid valve and secondary regulator • Line circuit breaker • Multi -fuel system, LPG/naturalypts, field�onvertible • Oil drain extension with shutoff valve • Oil level sensor • Oil pressure sensor • KOHLER Energy Management System • Premium 5-year/2000 hour limited standby warranty. Covers parts, labor, and travel for the entire warranty period • RDC2 generator setIATS controller • Rodentresistantconstruction • Sound -deadening, flame-retardant foam per UL 94, class HE Available Options Concrete Mounting Pads ❑ Concrete mounting pad, 3 in. thick ❑ Concrete mounting pad, 4 in. thick (recommended for storm -prone areas) Electrical Accessories ❑ Battery ❑ Battery heater, 120 VAC' ❑ Carburetor heater, 120 VAC t ❑ Cold weather kit, 120 VAC tt o Includes oil and Heather tube heaters fuel regulator heater, and pressure sensor cover o QS model with factory-insUled kR is available (excludes fuel regulator heater) ❑ Emergency stop kit ❑ Programmable interface module (PIM) (provides 2 digital inputs and 6 relay corrals) ' eadery beater is recommendetl below -17"C (0"F). $ Do not use a carburetor heater with a cold weather kit t Cold weather kit is recommended] below 0"C (32"F). Enclosure Options (single-phase only) ❑ Kohler' Exclusive Colors Go to homeenergy.kohlemnergy.com to see the latest colors. ❑ Mossy Oak® camouflage enclosures Go to homeenergy.kohlemnergy.com/Mossyoak to see available patterns. Musty Oak m abademazkused uncerocense onto Haaz ONdcme, Inc., by omierCo. Fuel System Accessories ❑ Flexible fuel line (included on QS models) Discovery Energy, LLC 200 Twin Oaks Road, Kohler, WI 53044 USA For the nearest sales and service outlet in the US and Canada, phone 1-800-SM-24 KOHLEREnergy, rom Literature ❑ General maintenance literature kit ❑ Overhaul literature kit ❑ Production literature kit Maintenance ❑ Maintenance kit (includes air fiber, oil, oil filter, and spark plugs) ❑ Premium 300 hour/2 year oil for fewer oil changes Automatic Transfer Switches and Accessories ❑ Model ROT ATS ❑ Model RXT ATS with combined interfaceFload management board ❑ Load shed kit for RXT or RUT ❑ Power relay modules (use up to 4 relay modules for each load management device) 26RCAL Model Package ❑ 26RCAL with 200 amp service entrance -rated Model RXT with combined interface/load management board and carroson-resistant NEMA 3R aluminum enclosure Warranty ❑ 7-Year Limited Warranty ❑ 10-Year Limbed Warranty Warranties rover pans, labor, and travel for the entire warranty period. Generator Set Dimensions and Weights Generator Set Size, L x W x H: 1193 x 660 x 620 tom (47 x 26.0 x 32.3 in.) Skipping Weights: 26RCA Generator Set: 20 kg (625lb) 26RCAL with 200 A RXT SE ATS: 304 IN; (670lb.) L NOTE Dim-nmons are moomed be reverence only and should not be used for planning lnslarafkn. Conlacf your mal dealer for more denoted aomiadm_ DISTRIBUTED BY: ® N12<-O '—' Eneryy. LLC-All dgk6 enseon/ed G4315 (261mCA) 10cole