Loading...
HomeMy WebLinkAboutMF2022-0037551 City of Grapevine Building Inspection Department Plan Review Comments Letter P.O. Box 95104 Phone: (817) 410-3163 Grapevine, Texas 76051 Fax: (817) 410-3536 NAME OF PROJECT: Grapevine Brownstones DATE: 09 November 2022 ADDRESS: 218 E. Dallas Rd. Units 1-10 PERMIT #: 22-3754 through 22-3763 COMMERCIAL PLAN REVIEWER: LAWRENCE W. GRAY NUMBER OF STORIES: 4 TOTAL SQ. FT: 38,031 ZONING: PO/TDO OCCUPANCY: R-3 OCCUPANT LOAD: N/A EXITS REQD: N/A FIRE SPRINKLED: Yes BUILDING TYPE: VB CU22-02 SPECIFIC COMMENTS: 1. PLEASE NOTE THAT THERE ARE SEVERAL CITY DEPARTMENTS INVOLVED IN THE RELEASING OF THE PERMIT FOR ISSUANCE. DEVELOPMENT SERVICES PLAN REVIEW MAY BE COMPLETE, BUT THERE MAY BE HOLDS FROM OTHER DEPARTMENT REVIEWS. FIRE, PUBLIC WORKS, TARRANT COUNTY HEALTH. 2. REVIEW OF THE RESPONSE TO COMMENTS DOCUMENT SUBMITTAL MAY TAKE UP TO 10 BUSINESS DAYS TO COMPLETE. 3. PERMITS MAY ONLY BE ISSUED FOR CONSTRUCTION DOCUMENTS IN ACCORD WITH 2006 IBC SECTION 106.1. DOCUMENTS ISSUED FOR ANY OTHER PURPOSE WILL NOT BE ACCEPTED. 4. PROVIDE WALL TYPES AND CONSTRUCTION DETAILS. SPECIFICALLY, FOR THE REQUIRED 2 HOUR FIREWALL SEPARATION BETEEN THE UNITS. 5. REVISE PLANS TO PROVIDE FOR SPECIFIC DESIGNS ONLY. REMOVE ALL “OPTIONAL” FLOORPLANS FROM PLAN SHEETS. 6. CONTACT GRAPEVINE PLANNING SERVICES @ 817.410.3155 REGARDING CHANGES TO ROOFTOP STRUCTURES FOR APPROVAL. THE CUPOLAS INDICATED IN THE APPROVED CONDITIONAL USE ARE FOR A STAIRWAY LANDING/ELEVATOR LOBBY ONLY AND NOT APPROVED FOR ADDITIONAL INDOOR HABITABLE SPACE ON THE 4TH LEVEL. THIS MAY REQUIRE AN UPDATE TO THE APPROVED CONDITIONAL USE. 2 Common Plan Review Notes 1. Civil document approval by Grapevine Public Works Department. 2. Fire/Life safety document approval by Grapevine Fire Department. 3. Landscape document approval by the Grapevine Planning Division. 4. ADA/TAS compliance document/inspection approval by others. 5. E-com, info tech, and low voltage document approval by others. 6. Energy compliance document/inspection approval by others. 7. Specification document approval by others. 8. Floor wall and ceiling finishes shall be in accordance with 2006 IBC chapter 8, table 803.5 and section 1210 as applicable. 9. Egress doors with access control shall be in accordance with 2006 IBC section 1008.1.3.4. 10. Stairs shall be in accordance with 2006 IBC section 1009, including usable space under stairs, risers, treads, handrails, guards, etc. 11. Any glazing subject to human impact loads shall be in accordance with 2006 IBC section 2406. 12. Plumbing trap seals shall be in accordance with 2006 IPC section 1002.4. 13. Plumbing and exhaust vent terminations shall be in accordance with 2006 IPC section 904 and 2006 IMC section 802. 14. All mechanical equipment is required to be screened from view in accordance with Zoning Ordinance section 25.M.2. 15. Construction hours in the city are from 7 am to 7 pm Monday through Saturday and no work is permitted on Sunday. Site specific construction hours will be provided at the pre-construction meeting. 16. All projects receiving approval from City Council for Conditional Use must go back for re-approval should exterior changes in the projects occur, such as: (a) Exterior materials (b) Wall locations (c) Traffic direction (d) Landscaping (e) Etc. Allow 42 – 83 days for the re-approval process. 17. GFCI outlets shall be in accordance with 2005 NEC article 210.8(B). 18. Exterior signage is by separate permit application/approval and shall be in accordance with Zoning Ordinance Section 60. GENERAL COMMENTS: 1. COORDINATE ALL FIRE ALARM SYSTEM PLANS, APPROVALS AND INSPECTIONS WITH THE FIRE MARSHAL, BRYAN PARKER, AT 817-410-4420. 2. THE PROJECT SHALL BE DESIGNED TO COMPLY WITH THE 2015 IECC. VERIFICATION OF COMPLIANCE SHALL BE SUBMITTED TO THE CITY BY A CERTIFIED ENERGY CODE INSPECTOR PRIOR TO THE ISSUANCE OF 3 BUILDING FINAL APPROVAL. 3. ALL CHANGES FROM THE CITY APPROVED PLANS WILL REQUIRE REVISED PLANS SUBMITTED AND ADDITIONAL REVIEW FEES DUE. 4. THE CITY OF GRAPEVINE IS UNDER THE 2006 I CODES WITH THE 2015 I.E.C.C, 2015 IFC AND THE 2005 N.E.C. PLEASE PROVIDE FOR THESE CODES ON THE PROJECT DATA INFORMATION AND THE PROJECT DESIGNS. 5. PLEASE READ THE FOLLOWING NOTE CAREFULLY AND FOLLOW THE INSTRUCTIONS GIVEN. PLANS WILL NOT BE ACCEPTED THAT ARE REVISED AND DO NOT FOLLOW THESE REQUIREMENTS, THANK YOU. Please review comments and have designers add all review comments, required information and created changes, all clouded within new plan sets. Please provide 3 copies of new full corrected plan sets. Plan size may not exceed 36” in any dimension. A copy of this plan review letter shall accompany the “response to comments” sets of drawings. If required, review of response to comments will be placed on hold until Planning Services approval has been obtained. APPLICATION RECEIVED: 27 Oct. 2022 1ST COMMENTS: 09 Nov. 2022 REVISIONS RECEIVED: REVISIONS REVIEWED: PERMIT ISSUED: NuCiti Capital Partners, LLC 129 South Main Street Ste# 260 Grapevine, Texas 76051 1 : t 218 East Dallas Road Grapevine, Texas 7651 TERMITE TREATMENT WARRANTY CT Pest Solutions LLC hereby warrants all workmanship in accordance with the terms and conditions of the Contract Documents, Project Specifications and Product Label instructions - that were administered for the above referenced Project for a period of (5) five years from date of completion. CT Pest Solutions LLC agrees to repair, retreat and/or replace, at its cost, any new subterranean termite damage to the treated structure(s) and its contents that has occurred during the term of this warranty. CT Pest Solutions LLC will not be responsible for any repair or replacement to areas that were not directly affected by termite damage nor will CT Pest Solutions LLC be responsible for any indirect expenses or any consequential damages relating to the presence of termites or their damage. This warranty does not apply to additions or alterations that are made by buyer which affects the original structure(s) or treatment(s). Examples include, but are not limited to, landscape and mulch alterations - which disturb the treated area(s) and create new subterranean termite hazards. Nor does it include structural area(s) that has/ have been affected by water damage - we must be notified and allowed the opportunity to retreat area(s) prior to Owner's completion of repairs. CLAIM PROCEDURE: In the event a warranty claim is required, please contact: Carla Robinson / Owner # 214.537.8600 carla@ct-pest.com s WS cerel °" f ar t son Owner/Partner 214.537.8600 CT Pest Solutions LLC PO Box 3084 McKinney, Texas 75070 214.537.8600 TXPCL #0822997 (A) (B) (C) COMMERCIAL AND NON-COMMERCIAL PEST CONTROL USE RECORD Name of Customer or Contractor: NuCiti Capital Partners (Fadal Const) Address: 129 S Main Ste., Suite 260, Grapevine, TX 76051 Chemicals/Pesticides/or Devices Used: Dominion PT (A)EPA# 53883-227 Purpose for Which Chemicals/Pesticides/or Devices Were Used or Target Pest(s): Building 1 Chemical Application Dilutaion % 0.05% Square Footage Treated: 5,274 Linear Footage Treated: Gallons of Product Applied: 527 # of Application Tanks Used: 1 (1) Capacity (gallons) of Application Tanks: 1000 Start Time: 10:00am Completion Time: 10:45am Date of Application: 7/27/2023 Name & License # of Applicator Administering Treatment: Troy Fifield #559148 Name of Project: NCP Grapevine Brownstones Physical Address of Treated Site: 218 East Dallas Rd. Grapevine, TX 76051 Licensed and Regulated by: Texas Department of Agricutre P.O. Box 12847 Austin, Texas 78711-2847 P.O. Box 3084 McKinney, TX 75070 termites Telephone #888.918.4481 Fax #888.232.2567 Xi