Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
CA2026-19
ERTIFICATE OF APPROPRIATENESS APPLICATION Pro a Owner Name, Address 8� Phone Number T L LC, ��OS nA nFlrtn�l� DrZ ail Phone: Mobile: 6 1 "3r u Email: Property Address include any suite number Number Subdivision Tenant NametOccupancy/Use Request/Description of Work to �BeDcone e A A ILA Drawings/Sketches s/Sketches Attached Phot ra hs Attached oEs) o No o Curren o Historic 0 Material Sample(s) Attached lease list S tJ 5 44ge e I 'O�u 1 I hereby certify that this information is correct to the best of my knowledge and that the said work will be done in conformance with all submissions herein set forth, and in compliance with the City of Grapevine's Historic Overlay District Ordinances and Building Codes. APPROVAL OF A CERTIFICATE OF APPROPRIATENESS DOES NOT CONSTITUTE APPROVAL OF OTHER REQUIRED.,EUILD/NG PERMITS. , t Approv d- Staff HPC o peniea x Office Use Approved with Conditions: Chair— Historic Preservation Commission x Date Building Official THiS IS NOT A BUILDING PERMIT. A SEPARATE BUILDING PERMIT MUST BE FILED AND APPROVED BY THE BUILDING DEPARTMENT BEFORE STARTING WORK. DELIVER TO: HISTORIC PRESERVATION DEPARTMENT OFFICE 817-410-3556 636 SOUTH MAIN STREET, GRAPEVINE, TEXAS RECEIVED MAR 0 9 2026 W©7 A Future With A Past 10 March 2026 Trivan Roofing - Dave Custable 1084 Texas Trail Grapevine, TX 76051 817.247.4555 RE: HISTORIC PRESERVATION COMMISSION CERTIFICATE OF APPROPRIATENESS #CA26-19 311 SOUTH MAIN STREET GRAPEVINE, TEXAS 76051 This letter confirms on March 10, 2026 the Historic Preservation Staff approved with conditions #CA26-19 for the property addressed 311 South Main Street, legally described as Block 19, lot 12, City of Grapevine to the Grapevine Historic Preservation Ordinance 91-73 (Appendix G — Grapevine Code of Ordinances), as amended, for the following: 1. Install new Duro-Last roof system over the existing low slope roof; 2. Install a metal Duro-Last 2-piece metal fascia edge and wood nailer to cover top of existing parapet wall in the front fapade in a medium bronze color; 3. Install a metal Duro-Last 2-piece metal fascia edge and wood nailer over the top of the brick along the sides of the building in medium bronze color. 4. Installation of gutters and downspouts at the rear elevation of the building. with the condition that only the top course of brick is covered with the metal coping and that a permit be obtained from the Building Department. An approved Certificate of Appropriateness is not an approved building permit; a building permit is / is not required. Contact the City of Grapevine's Building Department at 811.410.3165 for fees and information regarding permits. Thank you, Q- ('t� Davi Ze: Historic Preservation Officer THE CITY OF GRAPEVINE HISTORIC PRESERVATION • 636 South Main Street • Grapevine, Texas 76051 Phone 817/410-3556 • Fax 817/410-3038 *C,AZ& - 19 This form must be completed for NEW CONSTRUCTION ADDITIONS AND RENOVATIONS SITE & BUILDING PLAN REQUIREMENTS Reference: Ordinance No. 2013-23 www grapevinetexas govldocumentcenter/view/$81 The following information is required for properties with Historic Landmark Subdistrict Overlays and within the Historic Grapevine Township District to make application for new construction, additions and renovations. Historic Preservation Officer Consultation Date: Time: (817.410.3197 817,410.3185) 1. Survey Plan 2. Site Plan 3. Floor Plans 4. Elevations S. Roof Plan der✓ A-tt'AGWO � 6. Street Facing Elevations {of proposed structure with building elevations of structures on adjacent properties.! 7. Photographs ✓ (of all four elevations for any building or structure to be altered or demolished.) 8. Foundation Plan 9. Historic Preservation Plan Property Lot Size a i "-->5 D Square Feet 3rJ� Building Size (not less than 1,200 sq. ft. or greater than 3,400 sq. ft.) Building Coverage (40% max) el 0�0 Building Height (35 ft. max) _ _oaf Garage Detached 500 sq. ft. max) Garage (Attached is included within the 3,400 sq ft. max) /V A Storage Shed (200 sq. ft. max) N.P' For Commercial Uses: Impervious Area % of Lot Parking Spaces ADA Parking Spaces Easements Board of Zoning & Adjustment approval PLEASE NOTE A SCHEDULED CONSULTATION WITH THE HISTORIC PRESERVATION OFFICER IS SUGGESTED SIX (6) WEEKS PRIOR TO REVIEW BEFORE THE HISTORIC PRESERVATION COMMISSION WITH; 1) THE ABOVE INFORMATION COMPLETED; AND 2) ALL REQUIRED ATTACHMENTS COMPLETED. ALL NEW CONSTRUCTION & ADDITION REQUESTS MUST BE REVIEWED, COMPLETE AND IN COMPLIANCE WITH HISTORIC PRESERVATION ORDINACE No. 2013-23 TO BE DEEMED A SUBMITTED APPLICATION. RECEIVED MAR 0 9 2026 Roof System Pre Con For Sean Shope 311 S. Main Street Grapevine, Texas 76051 ---ems - .- TriVAN Roofing Duro-Last° Platinum Contractor 1084 Texan Tra i I Grapevine, Texas 76051 www.trivanroofing.com 817-891-7313 877-4TriVAN License #03-0449 — RCA i Texas Endorsed #3146 — CIB Oklahoma Tr i VA N 1� PDUROLATINUM o�LAST. R O O F I N G RECEIVED MAR 10 2026 rk-,-../i r9 311 S. Main Street Grapevine, Texas 76051 Roof System Pre Con March 5, 2026 • Table of Contents — Roof System Components Page 3 — Project Inclusions/Exclusions Page 4-5 — Safety Area Page 6 — Metal Fascia detail for Historic Preservation Page 7-8 — City Permit Page 9 — Project Timeline Page 10 — Coping versus 2 Piece Compression — Next Practice Page 11 — Project Team Page 12 — Manufacturer Certification Letter Page 13 — Licensed Roofing Contractor Page 14 — HAAG Certified Inspector Page 15 — Metal Water Tight Warranty Certified Page 16 Tr i V A N z ;% OURO►LAST. F1 6 0 F I N G #100 PLATINUM CONTRACTOR RECEIVED MAR 1 0 90?�--- 311 S. Main Street Grapevine, Texas 76051 Roof System Pre Con March 5, 2026 1 Decking 2A n Install new Duro-Last° Roof System over existing modified bitumen roof 2 Insulation 1 ' " `IF Thickness Layers Product ?A %" 1 Duro-Guard® Cover Board Mech. Fastened 3 Membrane Thickness Sq. Ft. Product Fastening Type 50 Mil 2,500 Duro-Last® DL50 Prefabricated PVC deck membrane Mech. Fastened 50 Mil 1,000 Duro-Last® DLP50 Prefabricated PVC parapet membrane Mech. Fastened 4 Flashing uantit Duro-Last® Prefabricated PVC Flashing Flashing Type 4 RTU Curb Flashing and roof hatch flashing �� Closed 9 Vent Through Roof Stack Flashing Closed 0 Exhaust Fan Curb Flashing .._. Closed OQuantit Size Exceptional Metals® Prefinished Prefabricated 24 Ga. 30 LF 5" 2-Piece Edge Compression Edge Fascia Cover Detail 30 LF 5" Gutter g 30 LF 4"x 4" Downspouts. 200 LF Riglet Counterflashing 1 EA Pitch Pans 6 Accessories/Additional Services uantit Products/Services V v 3 EA. Duro-Last"' Two -Way Air Vents 7 Warranties • Duro-Last® 15-Year Consequential Damage No Dollar Limit Warranty • TriVAN Roofing Two Year workmanship warranty T_riVAN R O O F I N G %� DURD►LAST, I�W PLATINUM CONTRACTOR RECEIVED Yti MAR 10 2026 311 S. Main Street Grapevine, Texas 76051 Roof System Pre Con March 5, 2026 Project Inclusions • Preparation • Existing roof system is to remain in place. This is an overlay with new roof system. • Remove and replace existing gutters and downspouts • Furnish and install wood blocking where needed to meet roof manufacturer's requirements • Membrane • Deck— Mechanically attached 50 mil Duro-Last® PVC deck membrane • Parapet— Mechanically attached 50 mil Duro-Last® PVC parapet membrane • Insulation/Cover Board • Cover Board —Mechanically attach one layer of %" cover board which provides Class 4 Hail Impact Rating -Insurance Premium Discounts may apply • Fascia • 2-Piece Compression Flashing — Decorative edge metal at the front of the building • Metals • Edge Detail — Included • Gutters — Included • Downspouts — Included • Pitch Pans — Included • Roof Related Brake Metal Flashings — Included • Accessories • 2-Way Air Vents —One per 1,000 square feet as required by Duro-Last® • Other Equipment/Debris - This includes all lifts, trash removal, etc. Permit— Furnish City of Grapevine building permit Warranty — Upon completion, furnish the building owner with a Duro-Last 15 Year "NDL" warranty including consequential damages Exclusions • Curbs - Price does not include any curbs or roof stacks that need to be extended to meet minimum height requirements for Duro-Last® roof system • Standing Seam Metal Roofing and Wall Panels— This proposal does not include any standing seam metal roofing, metal wall panels, soffit panels, awnings, canopies or eyebrows • Mechanical, Electrical or Plumbing—TriVAN Roofing is not responsible for the HVAC system, condensers, nor damage to any roof lines during course of our installation and recommend that your HVAC tech, at the owner's cost be available if any service is required TriVAN 4 ��'i;%DUR T. R O O F I N G All PLATINUM CONTRACTOR RECEIVE® MAR 10 2026' 311 S. Main Street Grapevine, Texas 76051 Roof System Pre Con March 5, 2026 Roof System Design The color coded drawing below represents our takeaway of the requirements based on our assessment of your roof. If it is not represented in this drawing or the Roof System Components on Page 3, they are most likely not included in our scope. We recommend a scope review to insure we meet your requirements and include all the elements you require in our scope prior to executing an agreement. Roof Membrane Roof Top A/C Units 2-Piece Edge Details Roofs Not Included Gutter/Downspout Wall Flashing Tr i V A N DURO LAST. R o o F 1 N G ;fr&4 PLATINUM CONTRACTOR RECEIVED MAR 10 2026 _tcA2&- 7 311 S. Main Street Grapevine, Texas 76051 Roof System Pre Con March 5, 2026 Safety Area: In -side the red lines are the staging area and roof top access for the students. The bus can be parked behind the gazebo (not in photo) for student drop off and pick up. PPE provided by TriVAN: Safety Vest, Eye Protection, OSHA Supervisor PPE provided by Students: Jeans, Steel Toe Shoes, Long Sleeve Shirts TriVAN OSHA Toolbox Lesson TriVAN/Duro-Last provide water and lunch im 4 E _- ram_— i 0 f . ^W . - • r1' 6 .IO"* TriVAN 6 l j0 DU OOLMT. Fi O O F I .N c I13' PLATINUM CONTRACTOR RECEIVED MAR 10 2026� 311 S. Main Street Grapevine, Texas 76051 Roof System Pre Con March 5, 2026 Front building fascia size and color (Medium Bronze) will the same as on the 403 S. Main Masonic lodge T_riVAN R O O F I N G i�•:% DURD►LAST. I1#I1 PLATINUM CONTRACTOR RECEIVED -MAR 10 2026t""' #c.4z6 -49 Roof System Pre Con Front building fascia 2-piece edge detail is a wood nailer over top of brick with a fascia metal to cover nailer and covers 1 course of brick on the first top row of brick. "Brick towers will not be covered". TriVAN R O O F I N G 311 S. Main Street Grapevine, Texas 76051 March 5, 2026 -> Wood Nailer -> Metal fascia cover in Medium Bronze 8 DUR0,11AST. PLATINUM RECEIVED MAR 10 2026� #-C,A26-1 311 S. Main Street Grapevine, Texas 76051 Roof System Pre Con March 5, 2026 Both sides of building fascia 2- piece edge detail is a wood nailer over top of brick with a 4" fascia metal to cover nailer. Tri_VAN_ A O O F 1 N G 0 -> Wood Nailer -> Metal fascia cover in Medium Bronze -> Gutters/ Downspouts in Medium Bronze I% PDLlROoLATINUM�LAST.TRACTOR RECEIVED MAR 10 2026� �kcA2� -19 311 S. Main Street Grapevine, Texas 76051 Roof System Pre Con March 5, 2026 Bone White Stone White Almond PF - A - Classic Copper Metallic Sierra Ton Slate Gray edium Bron =1.rnish.d1la.te, Charcoal Gray Extra Dark Bronze Matte Black Regal Red P Terra Cola Hartford Green . Dark Ivy Blackout PFIA Sandstone Champagne Metallic. City Scapa Silver Metallic o Mansard Brown Dark Bronze Brandy Wine Colonial Red Aged Zinc P Hemlock Green P Sherwood Green Teal a Natural Patina Tropical Patna e Sky Blue Regal Blue a Award Blue a Electric Blue GALVALUME'Plus P - Denotes premium color Lead timesvary based on product availability and location. Call for up-to-date product availability and estimated lead times. To oV _A N o ��' PLATINUM AST. DECEIVED MAR 10 2026� 311 S. Main Street Grapevine, Texas 76051 Roof System Pre Con March 5, 2026 Coping Versus 2-Piece Compression — Next Practice We recommend the Duro-Last' 2-Piece compression system be used to terminate the membrane at the top of the parapet rather than coping cap. The membrane is fastened only on the outside of the parapet wall and meets or exceeds ES-1/ASCE-7 "Current" Standards to 90 MPH. Systems using coping caps require termination of the membrane through the top and inside of the parapet as shown below and this introduces points of failure into the roof system design. This is exacerbated by the fact that the coping itself requires a seam every ten feet and at corners. Each seam requires caulk to seal these seams that shrinks and fails within just a few years. The Duro-Last° Roof System eliminates both these issues completely. Duro-Last° 2-Piece Edge Traditional Coping Cap s Terminated on Outside Wall 2-Piece edge detail = Parapet wall warranty TriVA_N R O O F I N G Membrane Penetrations Inherent Maintenance and Upkeep Coping Cap = No parapet wall warranty 11 �� PDURDLATINUM oNL.ATRAST RECEIVED MAR 10 2926