HomeMy WebLinkAboutSFRA2026-001494 OT: -BLOCK: , ....-, SUBDIVISION:
BUILDING CONTRACTOR (company name):
CURRENT MAILING ADDRESS: >:
CITY/STATE/ZIP: :! �:! PH:# Fax#
PROPERTY OWNER:
CURRENT MAILING ADDRESS:
CITY/STATE/ZIP: PHONE NUMBER:
PROJECT VALUE: FIRE SPRINKLERED? YES NO
WHAT TRADES WILL BE NEEDED? ELECTRIC— PLUMBING— MECHANICAL
DESCRIPTION OF WORK TO BE DONE:
USE OF BUILDING OR STRUCTURE:
Total Square Footage under roof: Square Footage of alteration/addition:
I hereby certify that plans have been reviewed and the building will be inspected by a certified energy code inspector in accordance with
State Law. Plan review and inspection documentation shall be made available to the Building Department (required for new buildings,
alterations and additions)
• I hereby certify that plans have been submitted to the Texas Department of Licensing and Regulation for Accessibility Review.
Control Number- (Not required for 1 & 2 family dwellings)
• I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas
Department of Health.
(REQUIRED FOR DEMOLITIONS, ADDITIONS AND OR ALTERATION TO COMMERCIAL AND PUBLIC BUILDINGS)
I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by
the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. It is understood that the issuance of
this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. I FURTHERMORE UNDERSTAND
THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY, AND THAT THE
DESIGN PROFESSIONAL/OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND
OR FEDERAL AGENCY(S).
PRINT NAME: SIGNATURE
PHONE#. EMAIL:
CHECK BOX IF PREFERRED TO BE CONTACTED BY E-MAIL
THE FOLLOWING IS TO BE COMPLETED BY THE BUILDING INSPECTION DEPARTMENT
Aj,proval k) Issue
Setbacks
Construction Type: Permit Valuation: $
Occupancy Grour: Fire Sprinkler: YES NO Front: Electric
Division: Building Depth: Left: Plurnu��ng
Building Width: Rear: Mk �e. anical
Zoning:
Occupancy Load: Grease Trap Right. Rood
Plan Review Approval: Date: Building Permit Fee:
Site Plan Approval: Date: Plan Review Fee:
Fire Department: Date: Lot Drainage Fee:
Public Works Department: Date. Sewer Availability Rate:
Health Department: Date:- Water Availability Rate:
Approved for Permit: Date: Total Fees.:
Lot Drainage Submitted: Approved: Total Amount Due:
P.O. BOX 95104, GRAPEVINE, TX 76099 (817) 410-3165 O:FORMS%DSPERMITAPPLICATIONSI/02-Fiev.11/04,5106,
City of Grapevine Building - Residential
PO Box 95104 Accessory Structures
Grapevine, Texas 76099
817) 410-3166 Project # 26-001494
Project Description: Rebuild existing wood deck with steel
frame and railing and composite decking. [ELECTRONIC
REVIEW]
Issued on: 05/04/2026 at 8:40 AM
ADDRESS
INSPECTIONS
5
815 Spring Creek Dr.
1. Building Setback
4. Lot Drainage Inspection
Grapevine, TX 76051
2. Building Foundation/Footing
5. Building Final
LEGAL
3. Building Framing
Silver Lake Estates
Addition Bilk 1 Lot 101
INFORMATION FIELDS
S
—APPLICANT NAME (individual)
josh schoonover
PERMIT HOLDER
—APPLICANT PHONE NUMBER
8179090973
Joshua Schoonover
XustomLands
VALUATION
25000
(817) 909-0973
Square Footage
770
* CONSTRUCTION TYPE
VB
COLLABORATORS
- Joshua Schoonover
* OCCUPANCY GROUP
R-3
XustomLands
DOCUMENTS - MISC 01
-Buildingapplication-
(817) 909-0973
MartyMetzgerSigned.pdf
DOCUMENTS - MISC 02
MartyMetzgerdrainagesurvey.pdf
OWNERS
Martin MetzgerEng ineeri ng-
- Martin Metzger
DOCUMENTS - MISC 03
constructionset.pdf
DOCUMENTS - MISC 04
MartyMetzgersurveywithsetbacks.pdf
* ZONING DISTRICT
R-7.5
FEE
TOTAL PAID DUE
*Building Permit Fee (Value)
$443.00 $443.00 $443.00
TOTALS
$443.00 $443.00 $0.00
Page 1/2
MyGov.us 26-001494, 05/04/2026 at 8:40 AM Issued by: Amanda Robeson
I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE
NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY AND THAT
THE DESIGN PROFESSIONAL / OWNER IS RESPONSIBLEO OBTAINING
SUCH APPROVAL FROM APPROPRIATE STATEAND OR FEDERAL
May 04, 2026
Signature Date
City of Grapevine Building- Residential Accessory
Structures
Project # 26-00194
NOTICES
1) ALL work must be done in compliance with the 2021 INTERNATIONAL UIL I CODE.
"ALL work ISSUED prior to January 1, 2024, must be done in compliance with the 2006 INTERNATIONAL
BUILDING CODE.
2) City Approved Stamped Plans must be on -site for ALL INSPECTIONS.
) Project address must be clearly posted at the job site.
NOTES
INSPECTION
ET (17) 10- 010, CUT OFF TIME FOR A.M. INSPECTION IS 7:30 A.K --- CUT OFF TIME FOR P.M.
INSPECTION IS 12:30 P.M.
> PERMIT ISSUED IN ACCORDANCE WITHAPPLICATION I IN THIS.
MYGOV.us 26-001494, 05104/2026 at 8:40 AM Issued by: Amanda Robeson
CODES AND DESIGN CRITERIA
MISCELLANEOUS
1 PERFORM ALL CONSTRUCTION IN CONFORMANCE WITH THE BUILDING AND DESIGN
CODES REFERENCED WITHIN THESE DOCUMENTS THE PROJECT DOCUMENTS REFER TO
THE FOLLOWING CODES AND STANDARDS, UON:
TEXAS BUILDING CODE
MINIMUM DESIGN LOADS AND ASSOCIATED CRITERIA FOR BUILDINGS AND OTHER
STRUCTURES (ASCE/SEI 7-22)
2 RISK CATEGORY: I
3 LIVE LOAD
FLOOR
DECKS 40 LBS/SQ FT,
STAIRS 100 LBS /SQ. FT.
4 DEAD LOAD
FLOOR 15 PSF
GENERAL NOTES AND SPECIFICATIONS:
THESE PLANS WERE DESIGNED TO CONFORM TO THE 2021 INTERNATIONAL BUILDING
CODE AT THE TIME THE PLANS WERE DRAWN.
CONSTANT CHANGES IN BUILDING CODES, BOTH LOCALLY AND NATIONALLY, IN ADDITION
TO CHANGES IN ENVIRONMENTAL QUALIFICATIONS AND LOCAL OPTIONS FOR PLUMBING,
HEATING/COOLING AND WIRING, MAKES CONFORMITY TO ALL BUILDING RESTRICTIONS
IMPOSSIBLE CONSEQUENTLY, THE USE OF THESE PLANS IS SUBJECT TO LOCAL CODE
REQUIREMENTS AND INTERPRETATIONS,
IT IS THE RESPONSIBILITY OF THE USER TO EVALUATE THESE PLANS FOR CONFORMITY TO
LOCAL CODES REQUIREMENTS ANY ADDITIONAL DESIGN OR DRAWING SERVICES
REQUIRED BY LOCAL CODE ARE SUBJECT TO FINITE STRUCTURES & DESIGNS STANDARD
SERVICE FEES.
THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BEGINNING
ANY WORK AND NOTIFY OWNER OF ANY DISCREPANCIES
WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT
SCALE DRAWINGS.
DESIGNER, DOES NOT GUARANTEE THE AVAILABILITY OF ANY MANUFACTURED PRODUCT
SUGGESTED OR SPECIFIED ON THE PLANS OR SPECIFICATIONS
THE BUILDER IS ADVISED TO VERIFY THE AVAILABILITY OF ALL MANUFACTURED PRODUCTS
BEFORE PROCEEDING WITH CONSTRUCTION, ESPECIALLY THOSE ITEMS AFFECTING
ROUGH OPENING DIMENSIONS OR OTHER DIMENSIONS ON THE PLANS
ALL MANUFACTURED MATERIALS,COMPONENTS, FASTENERS, ASSEMBLIES, ETC., SHALL
BE HANDLED AND INSTALLED IN CONFORMANCE WITH MANUFACTURERS SPECIFICATIONS
AND INSTRUCTIONS. WHERE SPECIFIC PRODUCTS ARE CALLED FOR, GENERIC
EQUIVALENCE WHICH MEET APPLICABLE STANDARDS AND SPECIFICATIONS MAY BE USED
A CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR
TO BEGINNING WORK AND SHALL NOTIFY OWNER OF ANY DISCREPANCY
B CONTRACTOR SHALL BE RESPONSIBLE FOR ANY VARIATIONS OR
DEVIATIONS FROM THE PLANS WITHOUT WRITTEN CONFIRMATION FROM
DESIGNER
C. CONTRACTOR SHALL PROVIDE ADEQUATE BRACING OR OTHERWISE
SUPPORT ALL PORTIONS OF THE STRUCTURE UNTIL ALL MEMBERS HAVE BEEN
PERMANENTLY CONNECTED TOGETHER.
D PLUMBING DIAGRAMS OR DRAWINGS SHALL BE PROVIDED BY THE
PLUMBING CONTRACTOR
E HEATING/COOLING DUCT DIAGRAMS OR DRAWINGS SHALL BE PROVIDED
BY THE HEATING/COOLING CONTRACTOR
F HEAT LOSS OR ENERGY USE CALCULATIONS SHALL BE PROVIDED BY
HEATING COOLING CONTRACTOR OR OTHER PROFESSIONAL AS REQUIRED BY
BUILDING OFFICIAL.
G. TRUSS DESIGN, ENGINEERING AND PLANS SHALL BE PROVIDED BYTRUSS
MANUFACTURER
H EACH BEDROOM SHALL HAVE AT LEAST ONE WINDOW WITH A SILL
HEIGHT OF NO MORE THAN 44" ABOVE THE FLOOR.
I I ALL FIREPLACE OPENINGS SHALL BE PROVIDED WITH TEMPERED
GLASS DOORS. PROVIDE OUTSIDE COMBUSTION AIR FOR FIREPLACES, WOOD
STOVES AND LIQUID FUEL HEATING APPLIANCES
J SMOKE DETECTORS SHALL BE CONNECTED TO HOUSE POWER
K, TUB AND TUB/SHOWER ENCLOSURES TO HAVE 1/2" WATER RESISTANT
GYPSUM BOARD AND A HARD, MOISTURE RESISTANT SURFACE UP TO 6-0ABOVE FLOOR (MIN]
L ALL EXHAUST FANS.RANGE HOODS AND DRYERS SHALL VENT TO THE
OUTSIDE THROUGH SHEET METAL DUCTS CAULK AROUND ALL PENETRATIONS
THROUGH EXTERIOR ENVELOPE
M. ALL WINDOWS, PATIO DOORS AND DOORS WITH GLASS SHALL BE DOUBLE
GLAZED INSULATING UNITS WITH WOOD, VINYL OR THERMALLY BROKEN
ALUMINUM FRAMES AND SASHES
N ALL GLASS WITHIN 12" OF A DOOR AND/OR WITHIN 18" OF THE FLOOR OR A
WALKWAY SHALL HAVE TEMPERED GLAZING
O ALL WOOD IN PERMANENT CONTACT WITH CONCRETE OR SOIL SHALL BE
PRESSURE TREATED WITH A WATER BORN PRESERVATIVE.
P ALL EXTERIOR WALLS & WALLS COMMON TO UNHEATED SPACES SHALL
BE 2X6STUDS @ 16" O.C. WITH R-21 INSULATION UNLESS OTHERWISE NOTED ON
THE PLANS
Q PROVIDE 1 HR FIRE WALL BETWEEN GARAGE AND LIVING AREAS, AND
UNDER ALL STAIRS WHERE STORAGE SPACE IS AVAILABLE.
R ALL DOORS BETWEEN GARAGE AND LIVING AREAS SHALL BE 1 HR. FIRE
RATED ASSEMBLIES WITH 1-3/4" SOLID CORE WOOD DOORS OR CODE
APPROVED EQUIVALENCE AND SELF -CLOSING MECHANISMS
CONCRETE:
1 ALL FOUNDATION WALL AND FOOTING CONCRETE SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH
OF 3000 PSI @ 28 DAYS.
2 ALL CONCRETE SLABS SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH OF 2,500 PSI AT 28 DAYS.
3 CONCRETE FORMS, SHORING AND POURING METHODS SHALL CONFORM TO CURRENT A.C.I. STANDARDS.
4 BACK FILL SHALL NOT BE PLACED AGAINST BASEMENT RETAINING WALLS UNTIL,
A CONCRETE OR MASONRY GROUT HAS REACHED ITS 28 DAY STRENGTH, AND +-
B STRUCTURAL FLOOR FRAMING {INCLUDING SUB -FLOOR} REQUIRED TO STABILIZE WALLS IS COMPLETE
AND FULLY NAILED AND ANCHORED
5, APPLY STANDARD DRY WALL PRODUCTS, INC. "THOROSEAL FOUNDATION COATING" OR EQUAL FOUNDATION
COATING ON ALL EXTERIOR FACES OF WALLS BELOW GRADE, AND "THOROGLAZE" OR EQUAL DAMP PROOFING ON
ALL EXPOSED SURFACES OF CONCRETE WALLS ABOVE GRADE AND ALL SLABS NOT COVERED BY FINISH FLOOR MATERIALS.
REINFORCING STEEL:
1. ALL REINFORCING STEEL SHALL BE DEFORMED STEEL BARS CONFORMING TO ASTM A615, GRADE 60.
2. ALL REINFORCING STEEL SHALL BE MANUFACTURED DETAILED, FABRICATED AND PLACED IN ACCORDANCE WITH ACI 318R,
ACI 315R AND ACI SP 66
3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185, IN AS LONG A LENGTH AS IS PRACTICABLE WELDED WIRE
FABRIC SHALL BE LAPPED AT LEAST ONE GRID WIDTH PLUS 2'.
4. REINFORCEMENT SHALL BE BENT COLD AND SHALL NOT BE WELDED
SHEET INDEX
S-0 COVER SHEET
S-11 FOUNDATION PLAN
S-12 FRAMING PLAN
S-13 TYP. RAILING DETAIL
., iih.N
"P.^4
.n
oa,
F 7
�.. .. C 7 F F r
� r
O
Lu
u.j
X
V H
V w
z_ z
°C W
Ln Q
T-
op 0
COVER SHEET
S-0
/ I 4
, 6g-________
II._51
'.
51
n
0 58
n
•.
v
-
FOUNDATION PLAN
SCALE 1/4. - 1'-0'
POST TO FOOTING DETAIL
SCALE —
i
443 Rings EQ.
444 Bars
12X24 PIER SECTION
SCALE NTS
ry r
r) Ln
� O
w
W
cx� X
V I—
l7 w
z_ z
°C W
a �
Ln a
T- c2
oo 0
10 -4"
2X6 MEC TUBE JOIST in GAUGE 1 0 C
11-7 10-5
I I Lr)
O
Q0
Lu
12 0, uj
X
m.
LL!
Z
SHEATHING
ry >
-
2XJB�OECCTUBE JOIST j 0 Lu
@ <
Lr) c2
4X6 RED TUBE BEAM L 3X3X5/16 co
- WELDED TO BEAM
10x6
XI2
BASE PLATE (2) 5/8 ANCHOR BOLT
WELDED TO POST
FRAMING PLAN 4X4 SQUARE TUBE POST
SCALE 1/4'-- 1 -0'
50 __ 5-0'0C TIP
1 x2 TOP PAL -
1 X2 TOP RAL.
O
4X4 SQUARE TUBE POT
GRADE `I t I"
I12X24 PIER
TYP. RAILING DETAIL
SCALE 3/8' = V-U
1 /8 ABLEST O C
TURNSUCkE JOIST AT POST
I
III
I �
ke Rlt.i JCIiT
416 RED TUBE BEAM
P-T
WELDED TO THE DECK PERIMFER J0:5T
i
O
I M
i
d
NOTES FOR RAILING AS PER IBC:
CONNECTIONS MUST RESIST REQUIRED LATERAL THRUST; LAG SCREWS OR STRUCTURAL FASTENERS REQUIRED.
CONTINUITY ENDS MUST RETURN TO A POST, WALL, OR SAFETY TERMINATION MATERIAL & PROTECTION USE PRESSURE -TREATED LUMBER OR NATURALLY DECAY -RESISTANT SPECIES.
ALL FASTENERS AND HARDWARE MUST BE HOT -DIP GALVANIZED OR STAINLESS STEEL -SHARP EDGES & HAZARDS
- NO SPLINTERS OR PROTRUDING FASTENERS ALLOWED MAINTAIN SMOOTH, SAFE GRIPPING SURFACE OPENINGS IN THE GUARDS RAIL SHOULD NOT ALLOW A 4" SPHERE TO PASS THROUGH
ry r
`) Ln
Y O
W
LL X
V H
v LL
z_ z
°C W
d �
(n Q
T_ c2
op 0