COMA1999-0469
STRUCTURAL DECK EXTEND GYPSUM BD. TO DECK & SEAL — R19 (60) BATT INSULATION AT ENTIRE CEILING TEGULAR 2'X2' ACOUSTIC BD, IN PREFINISHED METAL GRIDS SUSPENDED FROM STRUCTURE ABOVE W / #10. WIRES AT 48' O.0 5/8' GYP.BOARD — 6' 25 GA. METAL @ 16' O/C R 11 BATT INSULF SCHEDULED FLOOF UL DESIGN 4U465 c 1 HR FIRE RATED WALL SCALEI 1/2' = 1' -0' BAIT INSULATION AT AT ENTIRE RE CEILING TEGULAR 20X2' ACOUSTIC BD SUSPENDED CEILING WHIT RACO' CHANNEL AT TOP OF RECCESSED EDGES IN PREFINISHED WALL DARK BRONZE ANODIZED METAL GRIDS, SUSPENDED FROM TYPICAL ALL INTERIOR WALLS STRUCTURE ABOVE BY #10 GALV. WIRES AT 48' O/C 5/8' GYPSUM BOARD ON EACH SIDE 3 -5/8 METAL STUDS @ 16. O/C R 11 BATT INSULATION IN BATHROOM WALLS SCHEDULED FLOOR BA - INT t F F' tPTIUN SCALE, 1/2' = 1'-0' R19 (6') BATT INSULATION AT ENTIRE CEILING - 5/8' GYP.BD.(WP,IN BATH RM,) ON 2-1/2' MTL, STUDS @ 16' O.0 R 13 BATT INSULATION ( DELETE INSULATION IF DEMISING WALL HAS ALREADY INSULATION ) SCHEDULED FLOOR BASE 4_ F LI P -- r] I T SCALE, 1/2' = 1' -0' I r 3 Y J a 3 a w w > D v x_11• DISPLAY LPA -21 I a RECEPTION /WAITING AREA O NOTE FLOOR TYPE RECESSED RECEP.W COVER PLATE BRUSHED CHROME TRIM AND COVER PLATE - - -. Q \ , _A�• / `36' HIGH SHELF, TYPICAL L�/PA- 9,11,13,15,17,19 70' -0' STYLING STATIONS PHONE it EACH -' ALL 11 STYLING STATION'S RECEPTACLES HEIGHT IS 30' FROM F.F - L 7 PA H,10,1? 14,16 DISPLAY 5_ I 5' -3• Q 6' P5 GA. METAL STUDS �D AT 16' O.C. AT THIS WALL L EXIST, MASONRY OR I ITE DEMISING WALL TE (u a n_ J I I -S - --- --- � � I I ` GAS =\ C, o o ST0REr RONT ELEVATION SCALEI 1/4' = 1' -0' N X w LL, I i 0N SCALE, 1/4' = 1' -0' 12' LOW VOLTAGE TRACK LIGHTING —INST. AVER CEILING GRIDS SPEAKER, RECESSED IN THE 1 CEILING AND WIRED TO STEREO LOCATION (TYPICAL) CEILING H. 10' -0' LPA DRYERS 0 � I THESE PLANS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY IT IS THE RESPONSIBILITY OF THE DESIGN PROFESSIONAL/ BUILDING OWNER TO OBTAIN THE NECESSARY APPROVA AD FROM THE PROPER STATE AND /OR FEDERAL AGENCY SHAMPOO in I ® (y) 1 - -- — - -- —,' ! 51-31 ENTER F WOOD BLKG. BET. STUDS WALL CAB. SHOULD BE 74• ABOVE F.F. 4 2'x 2' TEGULAR ePECESSED EDGE ) FISSURED ACOUSTIC BOARD IN PREPAINTED METAL GRID SUSPENDED CEILING e�X IT �ooQS Sll�►L� ©rolM �>c IuSI cJrl►}bJT —T`Ik� L1 es. OA= 'ps. 4jey 02 Ally SF�Ijt'" K► OLZL -&oGE:A G _ P 1 L �_ I E i �_L1L I'w.J f1NI� L_i _]�i 1N( -i LHIV / CALEI 1/4' = 1' -0' O U IL © r W=> SEPARATE PLUMBING, MECHANIC A L ELECTRICAL AND SIGN PERM IT5 Z o)4 I a S �' SHALL BE REQUIR`"I). GENERAL, MECHANICAL, ELECTRICAL, PLUMBING CONTRACTORS SHALL BE REGISTERED WITH THE CITY OF GRAPEVINE. REGISTRATION I FEE CITY APPROVED PLANS SHALL BE KEPT ON JOBSITE AT ALL TIMES, CONTRACTOR SHA L CAL FOR ALL INSPECTIONS Q AIR CONDITIONING DIFFUSERS, RE, A/C PLAN 6' L 31-6# - LPA -23 LPA -25 7 , TOILET PAPER All AAAAAAAA LPA -7 LPA -3 ,D S 1 1� LPA-5 c� W,H, F.D . WASHER DRYER F.D •D S UTILITY L ELEC, A LTTER (r 1 RECEPT. ATM GFI \� H. FOR STERE 3 4• 4 /A1 ATHRO I o a 5 /Ai C• `D OL I 4 ' GRA BAR B HRO011 O © I %AD 6'D I I LA GFI ;E: 30D a'D I oFN =— - -- - - - -_ = H GRAB BAR LPA -22 36' GRAB BAR ' CLEAN OUT PROVIDE 2'X8' WOOD BLKG. BET. STUDS FOR GR.BAR WALL SINK .SHAMPOO BOWL CAB. AND ETC, (TYPICAL) RECESSED TYPE 4'X2' FLOURESCENT LIGHT FIXTURE, W /BALLAST, REFLECTOR, 4 -R40 LAMPS, PRISMATIC DIFFUSER, WHITE TRIM HUNG FROM STRUCTURE ABOVE LSW -1 ( LITE NITE _ n _ LSW -1 120 CFM LOW NOISE EXHAUST FAN RUN 40DIM. METAL DUCT THRU ROOF- aCCE`- SIEILITY NOTES 1- HOT WATER PIPES AND DRAINS UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE COVERED, THERE SHALL BE NO SHARP OR ABRASIVESURFACES UNDER LAVATORIES, 2- HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES SHALL HAVE LEVER OR OTHER SHAPE WHICH WILL PERMIT OPERATION BY WRIST OR ARM PRESSURE AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING TO OPERATE, 3- FAUCET CONTROL HANDLES SHALL BE NO MORE THAN 17' FROM FRONT EDGE OF LAVATORY IN BATHROOM, AND IN BAR SINK. SELF CLOSING VALVES SHALL REMAIN OPEN FOR AT LEAST 10 SECONDS PER OPERATION , 4- INTERIOR DOORS SHALL OPEN WHEN EXPOSED TO A MAXIMUM FORCE OF 5 LBS, 5- EXTERIOR DOORS SHALL OPEN WHEN EXPOSED TO A MAXIMUM FORCE OF 8.5 LBS. 6- ELECTRICAL RECEPTICALES SHALL BE INSTALLED AT 150ABOVE FINISH FLOOR ELEVATION UNLESS ABOVE COUNTERS. NEXT TO SINK AND WHERE NOTED ON PLANS. 7- LIGHT SWITCHES SHALL BE INSTALLED AT 42' HEIGHT UNLESS OTHERWISE NOTED ON PLANS, 36'nln 120nln 12'nin I OPEN SIDE I I I SM L - - - - -J LINE OF - MISING WALL 19'tmx 52n1n FIXED -TILT CLEARANCE 25'rgx 170nIn LAV, DEPTH ?- TYPICAL ACI ! TY CITY OF GRAVINk\ N (a V�D TOE i wig Ll _ SHEET OF APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE THIS PLAN TO BE KEPT ON THE JO AT ALL AES DATE B BUILDING INSPECT DIV19K N APPROVAL DOES NOT APPLY TO CONSTRUCTION ON 04M- V - TITs nR nN PUBIC RIGHT- OF -WAV, 4U'LCR4AhX::SWAJSIF 'ENEI�F11� N[ITL S 1- ALL WORK SHALL BE EXCECUTED AS PER LANDLORD'S 1 TENANT CRITERIA AND THE SUPPLEMENTARY SPECIFICATIONS 2- ALL WORK SHALL MEET TEXAS ACCESSIBILITY REQUIREMENTS 3- SUBMIT PLANS TO TDLR PRIOR TO CONSTRUCTION . AAA �4io4i A -. `§ A f tip,. IVA / a1�- p........ •. ` t h „s, 3 -11 -99 2 bath rood 1 10 -23 -98 REV. # DATE REVISION 1,G,F, PREEN N HAIRCUTUS SCALE HALL- JOHNSON RD, @ HWY. 121 KM. sAUw+ow 4010 VD_LIAM R TATE AVE• SUITE 100 ` D GRAPEVINE , TX 76031 FLU LIU LING PLANS, DETAIL ATE DINMMIC' 10.NBrn SOLID WOOD PAINT GRADE DOOR FRAME SOLID CORE STAIN GRADE BIRCH VENEE WOOD DOOR NEMA 3R ENCLOSURE SERVICEEA /CTRTU LOCATED @ RTU A/C SW 240A PER NEC USE RATED 100,000 A/C 60A PROTECTIVE 30 3W COVER SAFTEY M.F SWITC 3 # 6 THHN TO ROOF TOP A/C UNIT 60A FIOOA 32 CKT 3/4• C 240V SERVICE 30 3W PANEL PLA DIS. SW50A 3 # 2 A, C &N THHN 1 -1/4 C 6' X 6' X 36' GUTTER INSIDE LEASE SPACE ------ -- -- --- - - - - -- - - - - -- -- - ----. --------------- - - -- OUTSIDE ELECTRICAL L�IA��R�'aM 1/4' CLEAR TEMPERED ( IN TRANSOM ALUMINIUM DOOR FRAMI 1/4' CLEAR TEMPERED GLASS IN I .'i7[�R' TYPE I: SCALE 1/4' =1' -0' DOER TYPE A SCALE 1/4' =1' -0' SER`IVI _ 200A 240 VAC 30 4W DIS. SW. GROUNDING _ 150 AF PER NEC NEMA 3 3 # 3/0 THHN A,C, &N ELECTRIC 1 03 THHN B METER M 2' C EXIST. BUILDING MAIN WIREWAY DEER DR # DOOR SIZE TYPE MAT. FRAME HD SET REMARKS 1 3' X 7' X 1 3/4' A GL. ALUM. ALUM. 1 EACH 2 3' X 6' X 1 3/40 H SC. WD. SD. WD 2 1 3 3' X 6' X 1 3/4' B SC. WD. SO. WD. 3 INTERIOR DOORS 1 EACH OVERHEAD DOOR CLOSURE SET #2 1- 1 /2PR, HEAVY DUTY 4X4 FULLY MORTISE BUTT HINGES (BRUSHED CHROME) I'❑❑ NE I ROOM NAME FLOOR SET #1 1 EACH OFFSET PIVOT, CENTER OFFSET PIVOT, HEAD OFFSET PIVOT HINGE HAVE 1 EACH PUSH BAR, FULL HANDLE GP.LPT, 1 EACH ALUMININM THRESHOLD WITH VINYL WEATHER STRIP 3' -0' LONG EXTERIOR DOORS 1 EACH VINYL WEATHERIZING AROUND DOOR TO A MAXIMUM FORCE 1 EACH DEADBOLT WITH KEYED CYLINDER (KEYED FROM OUTSIDE & WITH 12 -CANS @100W X 1.25 =150OW =6.25A 6.25 4 TURNPIECE INSIDE INTERIOR DOORS 1 EACH OVERHEAD DOOR CLOSURE SET #2 1- 1 /2PR, HEAVY DUTY 4X4 FULLY MORTISE BUTT HINGES (BRUSHED CHROME) 1 EACH PASSAGE LATCHSET #4 1 EACH PAIR OF LEVER HANDLES (BRUSHED CHROME) A` 36' 1 EACH FLOOR TYPE DRUM DOOR STOP (BRUSHED CHROME& BLACK RUBBER) SET #3 8.25 GP.EPT. SAME AS SET #2 EXCEPT USE PRIVACY LOCKSET INSTEAD 10.0 12 6 OF PASSAGE LOCKSET I'❑❑ NE I ROOM NAME FLOOR BASE WALLS #1 DOORS #1 SHALL HAVE A SIGN ON OR NEAR DOOR READING AS, GP.LPT, 'THIS DOOR SHALL BE REMAIN UNLOKED DURING BUSINESS HOURS.' #2 EXTERIOR DOORS SHALL OPEN WHEN EXPOSED TO A MAXIMUM FORCE 30/2 OF 8.5 LBS. DRYERS 12 -CANS @100W X 1.25 =150OW =6.25A 6.25 4 #3 INTERIOR DOORS SHALL OPEN WHEN EXPOSED TO A MAXIMUM FORCE 4 OF 5 L BS. 5 2.0 #4 DOOR HARDWARE SHALL BE MIIUNTFD A` 36' A.F.F. F III RM. # ROOM NAME FLOOR BASE WALLS CEILING REMARKS I RECEPTION &WAITING CR. TL, GCB GP.LPT, 2'X2'AB 1400 SQ.FT. @3W X 1.25 =5250W =14.6A 2 STYLING STATIONS 12 2011 29- 2'X4'@160 X1.25 =580OW =16.OA 16.0 30/2 3 DRYERS 12 -CANS @100W X 1.25 =150OW =6.25A 6.25 4 6.25 12 EXHAUST FANS @ 277V 20 2.0 4 SHAMPOO 5 2.0 GENERAL RECEPTACLES @ 120V SPACC 5 UTILITY ROOM 8.25 10 8.25 8.25 GP.EPT. B 10.0 12 6 BATHROOMS 45.8 STYLING STATION CREPT. 45.8 CLOTH DRYER @ 240/12OV, 10 CR. TL. -- CERAMIC TILE 12'X12' WHITE SAMPLE TO BE APPROVED BY OWNER. GP, LPT. -- GYPSUM BOARD, TAPED. FLOATED. & SANDED SMOOTH PAINTED WITH 2 COATS OF LATEX PAINT SEMI -GLOSS FINISH GP. EPT, -- SAME AS ABOVE BUT PAINTED WITH 2 COATS ENAMEL BASE PAINT, SEMI -GLOSS FINISH V.C.B. -- 40 VINYL COVE BASE BLACK, SAMPLE APPROVED BY OWNER 2'X 2' AB -- 21X2' TEGULAP (RECESSED EDGE) WHITE FISSURED ACOUSTIC BOARDS IN PREFINISHED METAL GRIDS, SUSPENDED FROM STRUCTURE ABOVE WITH #10 GALVANIZED WIRES AT 48' O.C. MAXIMUM. SC.WD. -- SOLID CORE STAIN GRADE BIRCH VENEER DOOR, SD. WD. -- PAINT GRADE SOLID WOOD DOOR FRAME, ELECTRICAL LOAD ANALYSIS : r? C K T, S E R V I C E PANEL 200 A, 120/240V, 3 0 3 W 150A M.C.B. DESCRIPTION 120/208 V WIR SIZE A B C N LIGHTS @ 277V DESCRIPTION TRACK +SPOT LIGHT 2011 12 1400 SQ.FT. @3W X 1.25 =5250W =14.6A 1 2 10.0 12 2011 29- 2'X4'@160 X1.25 =580OW =16.OA 16.0 30/2 16.0 22.5 12 -CANS @100W X 1.25 =150OW =6.25A 6.25 4 6.25 12 EXHAUST FANS @ 277V 20 2.0 2 @ 2A 5 2.0 GENERAL RECEPTACLES @ 120V SPACC 11 @ 180W = 1980W =8.25A 8.25 10 8.25 8.25 STYLING STATION & HAIRDRY RECEPT. @ 120V B 10.0 12 2011 11 @ 1000W = IIOOOW " =45.8A 45.8 STYLING STATION 45.8 45.8 CLOTH DRYER @ 240/12OV, 10 9 0 10.0 1 GAS FIRED, POWER FOR 20/1 STYLING STATION STYLING STATION (ELECTRICAL BACKUP) =22.5A 22.5 10.0 22.5 22.5 WASHER MACHINE @ 120V 10.0 12 2011 STYL "NG STATION I @ 150OW : =63A 6.3 2011 6.3 6.3 WATER HEATER @ 240112OVo 10 4 N%AB 10.0 12 GAS FIRED, POWER FOR STYLING STATION. STYLING STATION 2011 IGNITION, 1 @ 190OW =8.3A 8.3 15 8.3 8.3 SIGN 12 2011 STYLING STATION I @ 120OW 120 =5.OA 5.0 12 5,0 5.0 ROOF TOP A/C UNIT, GAS FIRED, ELECT. COOLING 35 35 35 20/1 35 A MAXIMUM FUSE SIZE 10 10 10 12 25 '/, LARGEST MOTOR 19 0 10.0 TOTAL 165,4 HAIR DRYER 165.4 98.15 2011 12 7.5 21 PANEL PI : r? C K T, S E R V I C E PANEL 200 A, 120/240V, 3 0 3 W 150A M.C.B. DESCRIPTION C K T I BRK WIR SIZE LOA CON A C LOA CON WIR SIZE C K T BRK DESCRIPTION TRACK +SPOT LIGHT 2011 12 10.4 1 2 10.0 12 2011 SIGN DRYER MACHINE 30/2 10 22.5 3 4 10.0 12 2011 J -BO( 5 6 SPACC WASHER MACH. 0/2 10 12.5 7 B 10.0 12 2011 STYL NG STATION STYLING STATION 20 11 12 10.0 9 0 10.0 1 12 20/1 STYLING STATION STYLING STATION 2011 12 10.0 11 2 10.0 12 2011 STYL "NG STATION STYLING STATION 2011 12 10.0 13 0,.r 4 N%AB 10.0 12 2011 STYLING STATION. STYLING STATION 2011 12 10.0 15 6 10.0 12 2011 STYLING STATION STYLING STATION 2011 12 10.0 17 10,0 12 20/1 HAIR DRYER STYLING STATION 2011 12 10.0 19 0 10.0 12 2011 HAIR DRYER RECEPTACLES /FRO, 2011 12 7.5 21 7.5 12 20/1 RECE DTACLES /BAI WATER HEATER 30/ 10 209 .8 2 4,5 12 20/1 RECEPTACLES /CEIL, 1V2 2 SPACE SPACE 27 SPACE SPACE 2 0 SPACE SPACE 31 2 1 1 SPACE NOTE - IF GAS IS AVAILABLE IN THE CENTER, USE GAS -FIRED WATER HEATER AND CHANGE WIRING ABOVE TO SINGLE CIRCUIT #12 WIRE WITH SINGLE PHASE 20A CIRCUIT BREAKER. PAINT NOTES ELECTRICAL NOTES 1, ELECTRICAL SERVICE TO LEASE SPACE IS 120/240 VOLT 3 PHASE, 4 WIRE 2, TENANT WILL BE REQUIRED TO RUN ELECTRIC SERVICE TO HIS LEASE SPACE FROM LANDLORD'S DESIGNATED POINT OF SERVICE AS INDICATED ONLY METER AND DISCCONECT SWITCH WILL BE ALLOWED ON EXTERIOR WALL ALL OTHER EQUIPMENT SHOULD BE LOCATED ON INTERIOR OF LEASE SPACE 3. ALL WORK WILL COMPLY WITH THE LATEST APPLICABLE REVISION IF THE NATIONAL ELECTRIC CODE (N,E.C,) AND ALL MATERIAL USED WILL CONFORM WITH NEC RULES AND WILL HAVE BEEN APPROVED BY UNDERWRITERS' LABORATIRIES AND BE SO STAMPED, ALL WORK WILL ALSO CONFORM TO THE CITY ORDINANCE. ENTRY SERVICE WILL MEET THE APPROVAL OF CITY UTILITY CUSTOMER SERVUCE 4. ALL WIRE WILL BE OF SOFT DRAWN , ANNEALED, COPPER WIRE, HAVING A CONDUCTIVITY OF NOT LESS THAN 98i OF THAT OF PURE COPPER. 5. UNLESS OTHERWIRE SPECIFIED OR NOTED, ALL CONDUCTORS WILL BE STANDARD CODE GAUGE TYPE THW, THERMO PLASTIC INSULATED. 6. ALL WIRE NO. 8 AND LARGER WILL BE STRANDED. NO WIRE WILL BE SMALLER THAN NO. 12 7, ALL LIGHTING PANEL BOARDS WILL BE THE PLUG -IN CIRCUIT BREAKER TYPE FOR 1201280 VOLT PANELS. PANEL BOARDS WILL BE OF THE DEAD FRONT, LOAD CENTER WITH MAIN BREAKERS. 8, SWITCHES WILL BE IDENTIFIED ON THE EXTERIOR COVER BY NOTING THE EQUIPMENT THEY CONTROL, PANEL BOARDS WILL CONTAIN A DIRECTORY ON THE INSIDE DOOR INDENTIFYING EACH CIRCUIT, 9, ALL CONDUIT WORK, MOTORS, STARTERS, AND OTHER ELECTRICAL EQUIPMENT WIRED AND CONNECTED BY THE CONTRACTOR SHALL BE EFFECTIVELY AND PERMANENTLY GROUNDED TO THE WATER PIPING SYSTEM, 10. ANY PENETRATIONS THAT ARE MADE THROUGH THE EXTERIOR WALLS FOR CODUIT SHALL BE WEATHER SEALED AND WALL FINISH SHALL BE RESTORED. LANDLORD'S AGENT WILL PROVIDE PAINT COLOR TO MATCH EXISTING PRIOR TO TENANT'S COMPLETION OF CONSTRUCTION 11, ALL SERVICE SHALL BE EXTENDED FROM THE DESIGNATED SERVICE POINT TO THE LEASD PREMISES IN CONDUIT ALONG THE REAR WALL AS SHOWN IN TENANT CRITERIA 12, BALANCE ELECTRCAL LOAD ACROSS ALL THREE PHASES, SPECIALLY AIR CONDITIONING EQUIPMENT. 13, ALL ROOF PENETRATIONS SHALL BE PERFORMED BY THE LANDLORD'S ROOF CONTRACTOR, AT TENANT'S CONTRACTOR'S EXPENSE, THE TENANT'S CONTRACTOR IS RESPONSIBLE FOR CONTRACTING AND COORDINATING DIRECTLY WITH THE LANDLORD'S ROOFER. 14, THE TIME CLOCK FOR TENANT'S SIGN, IF ANY, SHALL BE SET TO COINCIDE WITH THE OPERATING HOUR OF THE CENTER AS REQUIRED IN THE SIGN CRITERIA FOR THIS CENTER, GENERAL NOTES 1. ALL ROOF PENETRATIONS AND ROOF CURB FLASHING SHALL BE PERFORMED BY A ROOFING COMPANY AS DESIGNATED BY THE LANDLORD, AT GENERAL CONTRACTOR'S EXPENSES 2. ALL ELECTRICAL ROUGH -IN WORK MUST BE INSPECTED BY LANDLORD'S AGENT BEFORE COVER -UP, CALL FOR INSPECTION IN DUE TIME, 3. OTHER THAN SPECIFICATIONS INDICATED ON THESE PLANS, GENERAL CONTRACTOR SHALL ADHERE TO ADDITIONAL SPECIFICATIONS AND DETAIL DRAWINGS AS MENTIONED IN THE 'TENANT CRITERIA' AND AS ISSUED BY THE LANDLORD. 4. ALL RECEPTACLES AND SWITCHES AND THEIR COVER PLATES SHALL BE WHITE COLOR 5. ALL RECEPTACLES EXCEPT AT LAVATORIES, ON COUNTERS AND EXCEPT AS NOTED SHALL BE INSTALLED AT 150A.F.F. 6. ALL WALL SWITCHES, UNLESS OTHERWISE NOTED, SHALL BE INSTALLED AT 42' A.F.F. 1 - ALL INTERIOR WALL COLORS SHALL BE 'HOSPITAL WHITE' 2 - STAIN INTERIOR DOORS MATCH TO PIONITE LAM, ( OIL CHERRY *-WC 421 -S SUEDE )AND PAINT FRAME WITH 1 COAT PRIMER AND 2 COAmE OIL BASE ENAMEL PAINT, SEMI -GLOSS FINISH. COLOR TO BE WHITE PER OWNER'S SAMPLE OR PER OWNER'S APPROVED COLOR CHIP, NOTES 1, COORDINATE ALL UTILITY REQUIREMENTS WITH POWER COMPANY & MAKE ARRANGEMENTS AND PAY ALL FEES REQUIRED FOR CONNECTION:: OF ELECTRICAL UTILITIES. 2. MAKE THE INSTALLATION IN A MANNER THAT WILL COMPLY WITH APPLICABLE CODES AND LAWS. 3. ALL WIRES SHALL BE COPPER THW OR THHN, WITH MINIMUM SIZE OF #12 AWC, 4. PROVIDE SERVICE TO ALL APPLIANCES, FIXTURES, AND HVAC EQUIPMENT, i "14) 03 12 99 1 2 BATH ROOM REV, #1 DATE I REVISION . r a T,G,E, PRECISION HAIRCUTTERS '' AZ OMMDI #Y KK EMWUN HALL- JOHNSEIN RD. Q HWY. 121 4010 WILLIAM D. TATE AVE, SUITE 1 GRAPEVINE, TX, 76051 ELECTRICAL, DOOR& WINDOW SCHEDULES DATE 4 01, 2 999 =A. 2 FLEX DUCT SIZES CFM RANGE DUCT SIZE 0 THRU 125 MINIMUM 6' 112' 126 THRU 250 MINIMUM 8' 0 251 THRU 350 MINIMUM 10' 0 351 THRU 600 MINIMUM 12' 0 601 THRU 850 MINIMUM I5' 0 P! !JMDIN�i HP11'1� V PIPE S1?E FIXTURE WASTE VENT CV HW BIDET 1 -112' 1 -112' 112' 112' WATER CLOSET 3' 2' 3/8' - LAVATORY 1 -112' 1 -1/4' 3/8' 3%8' SERVICE SINK 2' 1 -1/4' 1/2' 1/2' SHOWER 2' 1 -1/4' 1/2' 112' LAUNDRY TUB 1 -112' 1-1/4. 112' 1/2' FLOOR DRAIN 2' 1 -1/4' - - HOSE BIB - - 112' - BUILDING MAIN - - 3/4' - COLD WATER MAIN — — 3/4' — HOT WATER MAIN — — — 3/4' COLD WATER BRANCH — — 1/2' - HOT WATER BRANCH — — — 112' WASTE AND VENT PIPE TO BE PVC - 40. COLD AND HOT WATER TO BE TYPE 'L' COPPER. ASME 33/4' VACUUM IRt RIS —� RELIEF SALVE RELIEF VALVE HOT WATER "OLD WATER :GATE VAVE(TYP) 3 � /?IIIN PIPE WATER HEATER, FOR — R APAC[ITY tEl �LUNB, VIEWS r-F UA NL2FL[lOR TE'I< H�AT[_N META �gg (( ROOF TOP UNIT RREE pp RR `iNIT ATED REGULAT�R RETURN AI gg RISER CU EPRLY AIR LEtE` T R O `THAN )00 CFM R�TURN RIR 11NSLR,ATED LkEGISTER SIM IEIECTORS MOD FOR UWS 5 IN OR LARGER O .Y i YF'ICAL RPOFTOP UPJIT Pi_Ur °1.'ING LEGEND - - - - - -- VENT —C— COLD WATER —H— HOT WATER -jl- DRAIN LINE - -I�B -- UNION —pQ•— GATE VALVE VTR VENT THRU ROOF Co CLEAN OUT FD FLOOR DRAIN QWATER HEATER E3 HAND SINK p WATER CLOSET ® LAVATORY ROOF TOP AIR f -3• VENT CONDITIONONG UNIT 00 I TIE INTO / 100 .. I COMMON VENT � 1 LINE'. w^ I 11VC� 1' PVC CONDENSATE /i 0000 3/4C �. DRAIN PIPE FROM A/C 0000 � 2/v4 N UNIT, ROUTED AND 0000/ �.�� V.0 CONNECTED TO P -TRAP 0000/ ?vE I �� OF SERVICE SINK / 0 I �? PROVIDE MIN 1 /8' PER /�/ 6. EACH FOOT OF HORN- / �// 4D ZONTAL RUN OF PIPE �/ / y 1 / / .00 . 4-- WATERNG I v2•N / / RATER MAIN LI 111 � 0000 IN CEILING rV / / /Exist, PLENUM 3R•C / / 3/4'H 0000 � VALVE 2'V , �/ / 0000 LAVATORY C 0000 10 C EXIST. 6' DRAIN � PIPE IN THE SPACE 6' H 3/4' H F.D. 3/4' c 73 TO 80 GAL fool WK ELECtR GAS GAL /. INSECT :.GREEN W /FLUE 24 6A, G.LFLUE RAINCAP L FLASHING ROOF SYSTEM I I ROOF TOP A/C UNITE fu�Il�;ZtTJ LL 2 1/2x2 1/2XI/4 BRACING FROM L 2 1/2X2 112XU4 BRACING AT TOP CHORD OF JOIST c AT MECH. UNIT CURB) OTHER END Of HECK UNIT NOT DOWN TO NEAREST BOTTOM CHORD PANEL POINT SUPPORTED BY ROOF BEAM OR IS JOIST GIRDER CF,FJSS `EI1-TION r-------- -- - - - - -I I I I I L 4 x 4 XI /4 FRAME I ROOF TOP A/C UNIT I TINDER NECK UMIT I L -- '�------ -" - -'A 2 1/2X2 1/2X1/4 BRACING ROOF JOIST �3' VENT 11 TIE INTO 1 COMMON VENT ' LINE ( I 3/4'C :4'D 3/4'H bA •` toot .%\ 3/4'C �2 /v'H 111 �\\ 11 \ r3 /40C 1 1 /2'C \` 3 /v'H 1 I1/2'H 1 2'V 11 �. LAVATORY 1 1 /21H �I ��� 3 D 2'V 1 1 I 1 /rC 11 6' CLEAN OUT V /P- IR 1 /2.11 1 1NSIDL SHAMPOO CAB. 2'V FLASH WITH FLOOk SLAB D SHAMPOO BOVLS 'D HA[RTRAP W /CLEAN -DUTJ I TYP Q SHAMPOO BOWLS CA NOTE 1 PLUMBING PIPING FOR THE SHAMPOO BOWL SHALL RUN INSIDE SHAMPOO CABINET. THE DRAIN PIPE FROM THE BOWL SHALL DRAIN INTO FLOOR SINK WITH PROVISION OF AIR GAP IN� -i IISI "v!F1 PROOF J131Sr I ' L 2 1/2X2 1/2X1/4 BRACING AT OTHER END OF NECK UNIT NOT SUPPORTED BY ROOF BEAM OR GIRDER 4 ROOF OPENING AND REINFORCING DETAIL 16 /14 I i HARDBOARD DUCT WITH INSULATION RE, NOTES ROOF 165.000 3 WATER H 75,000 E :6X14 ]VAC NOTES A. FIELD WRIT I ALL DO= All 311711111 AT JOB SITE B. NAE THE VTkLAT116 N A NWER DOT VLL MRY WITH APPUCQ1 11 AND LAWS. C. ALL U7 D f16LD6 DKATIII ARE (LIAR NSEIE BOM M D. AL SIBPLY AR NO US DIETS STALL K MATED ON 1' DG LAID( E" COIIRACTIR 9Wl 011RDDNTE VITFI STRI RK Di>NR FIR RF Da1Pk NT KTALAFB( F. ALL DIFRN :S WO TO BE MATTI AT THE BALM SIDE G. VRP VITA RICT91CM RR WIRE SRI, BEFORE COISTIMCTBR H. PROVIDE SIC CE UECTFR IN BOTH SIPPLY AR AND REIM AR U1 O AiI MIS LAMER THAN 5 TOl1 GEN -RAL N' RTES AT THE 1. ALL P OF POI TRATBNS NO ROOF CTRB III. AM SHALL BE MFLY PE11171 NEB BY A WX C1)PNIY AS BESIONTLD BY THE UADM AT IT ANT'S M(PACTDt'S EVENSE, VAL ALL R )9B6 AD AR CODITIIIPJ16 HIAH -( DARK MUST BE 1 /2'C NSPEC ID IT LNMOOS AII)IT BEFORE COO 40 CALL FOR NSPFT a IN RE TBE 1 /2'H I It USX TTU AR 00101ID1®6 LOOT MR TIM SPECIFIED IS 2•v I 4. UCAT' N OF RU TIP AR COMUT 106 11ET IS SUET TO v ASHER LMIIL RDT APPROVAL I *%' 5. HE P AO MUM DOTS 9YLL BE LIIGTO1 N MAMNIEZIR /rC l /rH v D ' METAL DULT AS IS E1 BY THE LAMUIRI V SERV, MR 'IAA SPECDI(AIIINS NDIfA`FD IN THIS PLAI6, OTERAL THku ROOF CKNW'TOt SHALL AMR TO ABDTUW SPECROTBNS AD 2 DSINK 1 AND A ISM BY THE LAOl1RD 1/r PRIMER VALVE _ 1 6' H 3/4' H F.D. 3/4' c 73 TO 80 GAL fool WK ELECtR GAS GAL /. INSECT :.GREEN W /FLUE 24 6A, G.LFLUE RAINCAP L FLASHING ROOF SYSTEM I I ROOF TOP A/C UNITE fu�Il�;ZtTJ LL 2 1/2x2 1/2XI/4 BRACING FROM L 2 1/2X2 112XU4 BRACING AT TOP CHORD OF JOIST c AT MECH. UNIT CURB) OTHER END Of HECK UNIT NOT DOWN TO NEAREST BOTTOM CHORD PANEL POINT SUPPORTED BY ROOF BEAM OR IS JOIST GIRDER CF,FJSS `EI1-TION r-------- -- - - - - -I I I I I L 4 x 4 XI /4 FRAME I ROOF TOP A/C UNIT I TINDER NECK UMIT I L -- '�------ -" - -'A 2 1/2X2 1/2X1/4 BRACING ROOF JOIST �3' VENT 11 TIE INTO 1 COMMON VENT ' LINE ( I 3/4'C :4'D 3/4'H bA •` toot .%\ 3/4'C �2 /v'H 111 �\\ 11 \ r3 /40C 1 1 /2'C \` 3 /v'H 1 I1/2'H 1 2'V 11 �. LAVATORY 1 1 /21H �I ��� 3 D 2'V 1 1 I 1 /rC 11 6' CLEAN OUT V /P- IR 1 /2.11 1 1NSIDL SHAMPOO CAB. 2'V FLASH WITH FLOOk SLAB D SHAMPOO BOVLS 'D HA[RTRAP W /CLEAN -DUTJ I TYP Q SHAMPOO BOWLS CA NOTE 1 PLUMBING PIPING FOR THE SHAMPOO BOWL SHALL RUN INSIDE SHAMPOO CABINET. THE DRAIN PIPE FROM THE BOWL SHALL DRAIN INTO FLOOR SINK WITH PROVISION OF AIR GAP IN� -i IISI "v!F1 PROOF J131Sr I ' L 2 1/2X2 1/2X1/4 BRACING AT OTHER END OF NECK UNIT NOT SUPPORTED BY ROOF BEAM OR GIRDER 4 ROOF OPENING AND REINFORCING DETAIL 16 /14 I i HARDBOARD DUCT WITH INSULATION RE, NOTES ROOF 165.000 3 WATER H 75,000 E :6X14 ]VAC NOTES A. FIELD WRIT I ALL DO= All 311711111 AT JOB SITE B. NAE THE VTkLAT116 N A NWER DOT VLL MRY WITH APPUCQ1 11 AND LAWS. C. ALL U7 D f16LD6 DKATIII ARE (LIAR NSEIE BOM M D. AL SIBPLY AR NO US DIETS STALL K MATED ON 1' DG LAID( E" COIIRACTIR 9Wl 011RDDNTE VITFI STRI RK Di>NR FIR RF Da1Pk NT KTALAFB( F. ALL DIFRN :S WO TO BE MATTI AT THE BALM SIDE G. VRP VITA RICT91CM RR WIRE SRI, BEFORE COISTIMCTBR H. PROVIDE SIC CE UECTFR IN BOTH SIPPLY AR AND REIM AR U1 O AiI MIS LAMER THAN 5 TOl1 GEN -RAL N' RTES AT THE 1. ALL P OF POI TRATBNS NO ROOF CTRB III. AM SHALL BE MFLY PE11171 NEB BY A WX C1)PNIY AS BESIONTLD BY THE UADM AT IT ANT'S M(PACTDt'S EVENSE, 2, ALL R )9B6 AD AR CODITIIIPJ16 HIAH -( DARK MUST BE NSPEC ID IT LNMOOS AII)IT BEFORE COO 40 CALL FOR NSPFT a IN RE TBE 3. USX TTU AR 00101ID1®6 LOOT MR TIM SPECIFIED IS SUB.E`l TO APPROVAL BY AKRTECT OR THE TDYAT. 4. UCAT' N OF RU TIP AR COMUT 106 11ET IS SUET TO LMIIL RDT APPROVAL 5. HE P AO MUM DOTS 9YLL BE LIIGTO1 N 1111, i1IPF01T ZOE SEE TETWOT CO6TRI 13 CRITERIA AS IS E1 BY THE LAMUIRI 6, MR 'IAA SPECDI(AIIINS NDIfA`FD IN THIS PLAI6, OTERAL CKNW'TOt SHALL AMR TO ABDTUW SPECROTBNS AD DUAL WAWW AS ME MXD IN T{1 WT CRITERIA' AND A ISM BY THE LAOl1RD PLUMBING FIXTURES AND TRIMS 1" WATER US[T, NERIEAN STANDARD'FAU ODENTED RASH VTLVL TOILET ND 3043182 All WHITE VDREDUS CIOM SEAT M M/N STANDAAD OT)I TDDR WITH ONfR WE 2. FLUSH VALVE 'SL K ROYAL' PfWT EM OROE FDOSH 3, LAVATORY NEREAR STWARD 'ROAN YN WALI- M6 TYPE VTFR[BUS OINA FROM OVERFUH, FACET LOLL 24924',4' CLRIERS, AND WITH OICEALED AM SIFPIRT. PRODUCT HIRER 1195289 4, LAVATORY FAIMiT , NERICAII STMRAB 1ERITANE' GEL Na 740 r2H, CITITFRCET FUET WITH VAKW- RESISTANT WRIST W HA IM 4' EDOER IDES , DIE FX% 5. WATER HEATER , `UOXNVAR' PROW I41,591B75 80 GALLON ELEL OR GAS-KW UNIT VENT SIN 4' 6. PRW VALVE ='.MGAM 88250' OR EDUA. RPUF 111P A/C UNIT 1. THE LMT IS WITH GAS HEATM AD DECTRE M)L 75 1116 CAPACITY, 3000 ❑TI DIE HEAT MAUI IS 163,000 1TU, 3/4' GAS PIPE CLI4EETHR ELECTRIC I1 lPTION IS 225, NO NAIL FUSE Slit IS 30 W. WIRE CDDECTO IS Be D1109W. 2. USE 'TM* CE D3CCON30 OR SDYIAR EDNL PPIlaJCL 3. IF GAS IS 101 AVARABLE N THE (ENTER, USE ALL D1CTRIC, 3000 CFI ROOF TOP LMT 'YORK' 210I501846, WITH HEAT EL 2HEMSM192S RUN 400 VENT TYPe 'B' DBL WALL THRU ROOF _ THERMOSTAT — — — - - - - -- �2QL)Ip1_F1= l� L1L11T !.J �Cf �o sF�LI l eal =1^ �cTT!)�."1 fay 5 ►., Cj 14 E C� i -ro es koke (J ��� fl I► j 1� 4 4 u 1 ROOF Tp A/C UNIT tjdp QT2 �LiL,j 7.5 TON= 3000 rFM 'SrrSCHE UIU E FOR DETAILS \ \ \\ 20/14 4'X24' S/A RE 20114 ISER — 4/14 TO 20/14 - - -- I v NJ I I I I 1 I I I I I I I 1 Li 2'X4' RECESS RETURN AIR 240X24' RECESSED TYPE REGT;TFR SUPPLY AIR REGESITER 390 CFM 12'0 FLEX DUCT RIGID DUCT TYPICAL IN SALON AREZ CONNECTION 720X4VOECESS (TOTAL 6 EACH) RETURN AIR RETURN AIR REGISTER RISER E 4'X24' E'1 i T�: C U N 1 1 1 L1 N I N F' L f 1 N SCALED 1/4' = V -0• 3 GAS PIPE DIAGRAM NOT TO SCALE TIE PIPE Siff IS � TED FM NAIL RUN METER PLUMBING NOTES A. In] VERIFY ALL MIN AN) CDWIDNS AT THE JOB SITE B. NAIT THE INSTALLATBN TN A MN O THAT VILL MFLY VITH APPLICABLE CM AND LAWS, C" M AID HOT WATER TO BE TYPE t' CtPPER. SANITARY No VENT TO BE PVC-44 D. EXTERIOR PIRK 9ALL BE, WATER LBE - PVC-40 SANDARY UK - SIR-41 E" ALL HOT VATER PIPES SNAL HAVE 1' THICK INSIMATIN F, CW9XTTR 9AL1 STMIZE ALL RIESTIC WATER PIPING ASlRBDIG TO AWA SPCMTIO6 G. VERIFY WITH O.ECTRIOIW FOR WIRE SIZE BEFORE CONSTRUCTION. Y 20/14 RUN 400 METAL DUCT THRU WALL ADD W.P. WEATHERHEAD AT END DRYER 150 CFM W.H. 800 FLEX 120 CFM 8'0 FLEX 120 CFM 8'0 FLEX 120 CFM EXHAUST FAN RUN 400 METAL DUCT THRU ROOF NOTE, 1 - 1500 LBS MAXIMUM ROOF TOP UNIT WEIGHT 2 - UNIT TO BE LOCATED IN THE GUTER 1/3 OF THE JOIST SPAN NEAR THE SUPPORT 6p HI!` L.1i1- 'I .. •� L ",e �f,. €e� "w,, 1 03 12 99 1 2 bath rood REV, #1 DATE I REVISION TGF PRECISI ❑N HAIRCUTTERS HALL - JOHNSON RD,E HWY ,121 4010 WILLIAM VATE AVE, SUITE 100 GRAPEVINE] TX. 76051 A TEXAS 77450 PL�JMBING & A/C PLANS,& T�ETAIL 117E pR///BNi