HomeMy WebLinkAbout26-001655ALL CHANGES REQUIRE APPROVAL OF REVISED PLANS SMOKE DETECTORS SHALL BE LINKED SO THAT WHEN ONE SOUNDS, ALL SOUND. APPROVED PLANS SHALL BE KEPT ON JOBSITE AT ALL TIMES SPECIAL NOTE PROVIDE SAFETY GLAZINGS AS REQUIRED PER SECTION 308 AND EMERGENCY ESCAPE AND RESCUE OPENINGS PER SECTION 310 OF THE INTERNATIONAL RESIDENTIAL CODE PROVIDE A SIGNED AND SEALED ENGINEERS LETTER CONFIRMING ONSITE INSPECTION AND APPROVAL OF ALL STRUCTURAL STEEL FRAMING, WELDS, AND CONNECTIONS CONSTRUCTION HOURS 7:00 A.M. - 7:00 P.M. MONDAY - SATURDAY ONLY NO WORK PERMITTED ON SUNDAY EXISTING EXISTING CONTRACTOR SHALL CALL FOR INSPECTIONS: (817) 410-3010 CONTRACTOR REGISTRATION WILL BE REVOKED UPON PERMIT EXPIRATION. EXISTING l W AU.PL ANFAGTORY.CAM SEPERATE PLUMBING, MECHANICAL, ELECTRICAL AND SIGN PERMITS SHALL BE REQUIRED. EXISTING RIDGE HEIGHT: ±171-011 " EX15TING EXISTING MAX BUILDING HEIGHT AT CHIMNEY: ±201-0 Il'40" PLATE t � � EXISTING EXISTING EXISTING EXISTING 8' PLATE ---------------------------------------------------------------------------------------------------------- ----- t EX15TING EXISTIWj Ll --------------------------------------------- EXISTING IT IS THE RESPONSIBILITY OF THE OWNER/ DESIGN PROFESSIONAL/ CONTRACTOR TO HAVE PLANS REVIEWED AND THE BUILDING INSPECTED BY A CERTIFIED ENERGY CODE INSPECTOR IN ACCORDANCE WITH STATE LAW. PLAN REVIEW AND INSPECTION DOCUMENTATION SHOWING COMPLIANCE WITH THE ENERGY CODE ADOPTED BY THE STATE SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT. RESPONSE TO COMMENTS 6-12-26 RECEIVED: 05/7/2026 26-001655 416 RIDGE ROAD RESIDENTIAL ADDITION & ALTERATION - - - - Il_6" PLATE - 8' PLATE_ ' ' ' ' ' ' ' '' FINISH FLOOR --------��---------------- --G-- �. . . . . . . . , - '-------- hjfEW FRONT EVATION NEW N CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 06/25/2026 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. FA PROVIDE SIGNED AND SEALED LETTER FROM REGISTERED ENGINEER CONFIRMING SITE INSPECTION AND APPROVAL OF PIER INSTALLATION WHEN WORK IS COMPLETE RUTHERFORD RESIDENCE 41(o RIDGE ROAD S� p,MP *S LOT 6 AND PORTION OF LOT -1 BLOCK �p 1 �\ MREPRODUCTIONOF RI1)GECREST ADDITION THESE PLANS BY ANY 4 * MEANS IS PROHIBITED ** CITY OF (2 RAPEVINE * THE PLAN FACTORY * TARRANT COUNTY * ARLINGTON, TEXAS ` 817-654-9012 (n � designers@planfactory.com Z Q NOTE: IT IS THE SOLE RESPONSIBILITY CALL THE DESIGNER TO OBTAIN LEGAL COPIES Q OF THE BUILDER TO VERIFY ALL y� * * OF THIS PLAN * * O< ASPECTS OF THIS PLAN AND TO ENSURE THAT THIS PLAN MEETS ALL �<<EGAL S� GOVERNING CODES 4 REQUIREMENTS. O - - O O m co Ln T � �D cc O i w w E 0 O I� O cyD / 1 I DESCRIPTION SQUARE FOOTAGE: E. LOWER AC: 1056 NEW LOWER AC:1019 E. UPPER AC: 1010 TOTAL A/C: 3085 E. GARAGE: 539 E. PORCH: 239 TTL AUR: 4163 Drawn Ms/Go Job 11223 Date 3/12/26 REV.* D,4TE: NA I NA PLAN NO. RUT�4ERF0RD PG. OF 13 1 10, I -1 23'-1" Ln F. GARA E I I I I J\ 111-511 0 12'-0" 0 = 8' F C. Y N�l MIA. - . OlU�MR SATW / 3'-6" 0 �. '112::4 64'-8" INJ 1"O"O� 0 0 rn6 13'-8" OO F. rUTCoWEN 13'-11" Ellml 1 1 13'-4" I E. II �t 23'-7" rn 8' F.C. cn N ;Z;k 10'-�111 ,r VF.C. A, Pr E. SAD 3 a 12' -10" 12'-3" 12'-call L s 41'-1" 1 F. FOORCW 8' F.C. 00, 0 UJUPLANFACTORY.COM :�P�P* VISE , - T F. C It S CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 06/25/2026 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVED. .LEGEND EXISTING WALL "E" = EXISTING NOTE: ALL EXISTING DIMENSIONS TO BE FIELD VERIFIED PRIOR TO CONSTRUCTION °Q)a"0iar.iz"-,aroi-dq ,fly 00 O cd W p�U+� cdto EE-- cd 0 s~ � � 6. 0 ,-) 0 0 0 o. �-14 p°-1� ai W 41 tom. E-+ R, O N HE"9oa4.�6.0IXA0 Q0 O Cfl I i z 0 i z I O co � co LO -.j O W i �D co U) O � I � w i Q lx z w i (D W I O W � o co DESCRIPTION SQUARE FOOTAGE: E. LOWER AC: 105(o NEW LOWER AC:10IS E. UPPER AC: 1010 TOTAL A/C: 3085 E. GARAGE: 5313 E. PORCH: 23S TTL AUR: 4163 RUTHERFORD RESIDENCE Drawn Ms/GD -� AMP / 416 RIDGE ROAD AND I Job 11223 5 S LOT 6 PORTION OF LOT BLOCK \ c **** * 0 i Date 3/12/26 OF RIDGECREST ADDITION ** THESE PLANSION BYANY * MEANS IS PROHIBITED * * CITY OF GRAPEVINE REV # DATE: * THE PLAN FACTORY * O TARRANT COUNTY * ARLINGTON, TEXAS ` ' ' I �j�� lP/� --'e j�l /� I A 817-654-9012 U) designers@planfactory.com * Z m * NOTE: IT IS THE SOLE RESPONSIBILITY PLAN NO. N CALL THE DESIGNER * Q OBTAIN LEGAL COPIESS OF THE BUILDER TO VERIFY ALL * OF THIS PLAN * * * * * O ASPECTS OF THIS PLAN AND TO RUTHERFORD /4* * t-EGAL s ENSURE THAT THIS PLAN MEETS ALL GOVERNING CODES t REQUIREMENTS. PG. 1 OF 13 ..=.--------1 JQ27=7, REMOVE BRICK U E. CL WT i T7 E Z I I I d._.►1 1111 -9 E dWER e F.c O =F— = F 7 LE �� 0 E. iKITCA4E l L I I II J E. D INWs ROOM F 11,\X� DIrlIi�ICs S' F.C. 11 n 1 J E. FOYIE'R r 0 n u UMPLANFACTORYZOM CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT 06/25/2026 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. LEGEND I EXISTING WALL DEMO "E" = EXISTING NOTE: ALL EXI5TING DIMENSIONS TO BE FIELD VERIFIED PRIOR TO CONSTRUCTION RUTI4ERFORD RESIDENCE 41(o RIDGE ROAD Sl AMP /S ti LOT 6 AND PORTION OF LOT I BLOCK REPRODUCTION OFRIDGECREST ADDITION THESE PLANS BY ANNYY 4 ** MEANS IS PROHIBITED ** m CITY OF GRAPEVINE * THE PLAN FACTORY * TARRANT COUNTY * ARLINGTON, TEXAS * 817-654-9012 designers@planfactory.com z n NOTE: IT I5 THE SOLE RESPONSIBILITY CALL THE DESIGNER TO LEGAL COPIES * OF THE BUILDER TO VERIFY ALL THIS PLAN * �ASPECTS OF THIS PLAN AND TO �ENSURE THAT THI5 PLAN MEETS ALL GAL S� GOVERNING CODES 4 REQUIREMENTS. 0 I O T[� LJ L CQ �o CYD co wEl- T E-1 cc 0 w w o 0 w � o DESCRIPTION SQUARE FOOTAGE: E. LOWER AG: 1056 NEW LOWER AG: 1019 E. UPPER AC: 1010 TOTAL A/C: 3085 E. GARAGE: 539 E. PORCH: 239 TTL AUR: 4163 Drawn Job 11223 Date 3/12/2(o REV.* . DATE: NA NA PLAN NO. RUTHERFORD PG. 3 OF 13 t E. GARAGE 4 g. CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 06/25/2026 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. REFER TO ENGINEERED STRUCTURAL PLAN FOR CEILING FRAMING T- 46' -1" 0 NIN NN 4o�o g W+ el�mu A Ra1L= iVET SPECS ir;,! PSI n � u � 3,p Gm W" 5,�, MW ei,, � 12 -4 4 -6" It - - LM�1 HIM � 3� . x �� 8' , �icRo 0 I I PROVIDE NEW LVL \�� I I NEW P. BATW ' I TO SUPPORT UPPER �KJ BEAM ��� �� [11 3' F.C. I I FLOOR J - �� __ �y ( �'II i0�� 1 I I AFTER SUPPORTING K--,/' �� I WALL IS REMOVED ` 3--/I I ' I , I o ,X, a 40 LVL BEAM I �� �� I I t 0 9 sNlvs 4 2 SNLvS O �' I I I t / I r—— — — — — — — — — — — — — — — — ---� ----------------------- All; NEW 11LI�G. , 1 1 1 11------� SNL 4 vs !Z SNLYS r------� j �t I , l46 OV F.C. j 5'-3" 36" C" I I cal 0 fD I� 3 � W/ DEEP CAB. BENCWM00*.1WES SHLVS SLvs It NEW i�RIM ARY SUITE � �� J/z:;All i ®_ e �0il NCI UMGM NEVI MM eM SPECIAL NOTE PROVIDE SAFETY GLAZINGS AS REQUIRED PER SECTION 308 AND EMERGENCY ESCAPE AND RESCUE OPENINGS PER SECTION 310 OF THE INTERNATIONAL RESIDENTIAL CODE LEGEND "E" - EXISTING NEW WALL EXISTING WALL IUMPLANFACTORY.COM .o0 00 CO U 41 cd o - RA � a co O� 2p�0,o CL) W o cam, O r. ° rn EI 111 0 IUX4 24 O a A c°� c0 CD Q0 E-I 0 cr i Z A O 0 r � � O c coLO �cc cc O CN� Z w i O r i O co e DESCRIPTION SQUARE FOOTAGE: E. LOWER AC: 1056 NEW LOWER AC:1019 E. UPPER AC: 1010 TOTAL A/C: 3085 E. GARAGE: 53S NOTE: ALL EXISTING DIMENSIONS TO E. PORCH: 23S SE FIELD VERIFIED PRIOR TO CONSTRUCTION TTL AUR: 4163 RUTHEIRFORD RESIDENCE Drawn Ms/GD 416 RIDGE ROAD 11223 S� AMP S LOT 6 AND PORTION OF LOT I $LOCK Job �\5 * * * * * * * -� 1 Date 3/12/26 * TRESE PLANTION OF RIDGECREST ADD IT ION MEANS IS PROHIBITED * �� CITY OF GRAPEVINE fRE V.# C)AT. * THE PLAN FACTORY * TARRANT COUNTY * ARLINGTON, TEXAS A A * 817-654-9012 (n I NI N ` designers@planfactory.com Z Q NOTE: IT IS THE SOLE RESPONSIBILITY PLAN NO. CP CALL THE DESIGNER TO * Qv OF THE BUILDER TO VERIFY ALL * OBTAIN LEGAL COPIES -9� * * OF THIS PLAN * * O, ASPECTS OF THIS PLAN AND TO RUTHERFOR /< < &GAL S�� D ENSURE THAT THIS PLAN MEETS ALL GOVERNING CODES i REQUIREMENTS. PG. 4 OF 13 J ---------------- I I I I I I I I I I I I I UAW-10LANFACTORY.CoM I I I I I I 1'41-611 cop OWNM - a- — — — - 8' F.C. I ,I r GT I ff L➢RAV E At -,I - i'MISAF CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 06/25/2026 BY: ARNOLDO RAMIREZ TSBPE: 1.3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVED. LE64END .6 "E" = EXISTING NEW WALL EXISTING WALL NOTE: ALL EXISTING DIMENSIONS TO BE FIELD VERIFIED PRIOR TO CONSTRUCTION RUTHEWORD RESIDENCE 5AMP 416 RIDGE ROAD \CD � * * * * *S LOT 6 AND PORTION OF LOT 7 BLOCK ti0 1 EPRODUCTTHESE PLANSION BYANY * RIDGECREST ADDITION * MEANS IS PROHIBITED ** ',cN CITY OF GRAPEVINE * THE PLAN FACTORY * TARRANT COUNTY * ARLINGTON, TEXAS 817-654-9012 'r designers@planfactory.com z * CALL THE DESIGNER TO NOTE: IT IS THE SOLE RESPONSIBILITY * Q OBTAIN LEGAL COPIES OF THE BUILDER TO VERIFY ALL X. .k '9� * * OF THIS PLAN * * O� ASPECTS OF THIS PLAN AND TO <<EGAL S� ENSURE THAT THIS PLAN MEETS ALL GOVERNING CODES t REQUIREMENTS. O I 0 O L C\l O c co U'D i I �D CC O � I � �JJ w I I Q w I O O / N 1\ I N DESCRIPTIONI SQUARE FOOTAGE: E. LOWER AC: 1056 NEW LOWER AC: 1019 E. UPPER AC: 1010 TOTAL A/C: 3086 E. GARAGE: 539 E. PORCH: 239 TTL AUR: 4163 Drawn msiGr-> Job 11223 Date 3/12/26 � REY.* DATE; � NA NA � PLAN N0. � RUtHERFORD � PG. OF 13 � SMOKE DETECTORS SHALL BE LINKED SO THAT WHEN ONE SOUNDS, ALL SOUND. 0 } FRE ANDIWS TU VER PECS j II % 10 j O , _ -----4 O� I I I i I--------- ------- ----------� I j ® I I I � �1 I I--------- I I II II IIl cr 0 0 —� O .1 T f7 ,GRAB VINE T E X 1 S' CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 06/25/2026 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVED. WMPLANFACTORY.COM JELECTRICAL LEGEND r � W y IN 111 0 €) 0 ~ a)7:1 az a)��� 0 0 - E- O ' w w •i .. F" co >d .. �� 7-'0r-:0.- CO a v .� CEILING FAN WITH '( E-°°'�°'�' LIGHT KIT H0���a��ia o VERIFY WITH OWNER E- = o a�. c. 0 rz Q 0 EXHAUST FAN AND LIGHT COMBINATION EXHAUST FAN i'X4' FLUORESCENT FIXTURE O SUi;T-ACE MOUNT C-0 VERIFY WITH OWNER 2'X4' FLUORESCENT FIXTURE SURFACE MOUNT F-I VERIFY WITH OWNER �� ^ I � � RECESSED LIGHT FIXTURE 0 RECESSED WALL -WASH FIXTURE INCANDESCENT FIXTURE VERIFY WITH OWNER SCONCE L IGHT O HANGING LIGHT LIGHT FIXTURE c LIGHT STRIP W ^ TRACK LIGHTING I �D 03 UNDER UPPER CABINET V 1 STRIP LIGHTING (� UPL IGHT W i I Q DOUBLE -HEAD FLOOD FIXTURE 110 v WATERPROOF 20 AMP G.F.I. OUTLET - W I 110 v GROUND FAULT I INTERRUPTER OUTLET 220 V. OUTLET E- VERIFY HEIGHTS 0 110 v FLOOR OUTLET SEE OWNER /LOC.� O EVE PLUG I cyD 110 v AT CEILING 110 V. OUTLET VERIFY HEIGHTS SWITCH THERMOSTAT ,J SMOKE DETECTOR/ DESCRIPTION CARBON MONOXIDE DETECTOR COP—t-U SQUARE FOOTAGE- AC/DC E. LOWER AC. 1056 CHIMES NEW LOWER AC: 101g TELEVISION E. UPPER AC: 1010 TELEPHONE TOTAL A/C: 3005 E. GARAGE: 539 E. PORCH: 239 NOTE: ELECTRICAL LAYOUT IS PROVIDED ONLY AS A GUIDELINE FOR BASIC FEATURES. IT IS THE SOLE RESPONSIBILITY OF THE BUILDER TO COMPLY WITH AL 'TL AUR: GOVERNING AUTHORITIES. RUTHERFORD RESIDENCE 416 RIDGE ROAD S1 AMP / S LOT 6 AND PORTION OF LOT I BLOCK \7 **** *� ** 1 O REPRODUCTION OFRIDGECREST ADDITION THESE PLANS BY ANNYY ** MEANS IS PROHIBITED ** CITY OF GRAPEVINE ` * THE PLAN FACTORY * 0 T,4RRANT COUNTY * ARLINGTON, TEXAS * 817-654-9012 * (n designers@planfactory-com * Z Q NOTE: IT IS THE 50LE RESPONSIBILITY / * CALL THE DESIGNER TO * Qv OBTAIN LEGAL COPIES * OF THE BUILDER TO VERIFY ALL y OF THIS PLAN * O< ASPECTS OF TH 1 S PLAN AND TO �� E* * * S�' ENSURE THAT THIS PLAN MEETS ALL GAL GOVERNING CODES 4 REQUIREMENTS. 4163 Drawn Ms/moo Job 11223 Date 3/12/26 REV.*' DATE: NA NA PLAN NO. RUTHERFORD PG. ro 05 13 I I I I ; — I L I I PAP VINE CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 06/25/2026 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVED. SMOKE DETECTORS SHALL BE LINKED SO THAT WHEN ONE SOUNDS, ALL SOUND. Nz I I __ Old we _' Or, 0 0�d az 0��� WWW.f=LANf=AC:T0RY.C:0M 0 0�x�cd 0�°D� El 0 0 ELECTRICAL L � Q �� >� a >~¢ �� y, rA �z � 0 I~ 0- 0 0. rA 6Lr! r CEILING FAN WITH w'' ` 00, LIGHT KIT 'r, E_ :~ d � 0 VERIFY WITH OWNER E—:: 0 Q EXHAUST FAN AND LIGHT ® COMBINATION ® EXHAUST FAN co i'X4' FLUORESCENT FIXTURE SURFACE MOUNT VERIFY WITH OWNER 2'X4' FLUORESCENT FIXTURE / SURFACE MOUNT = .� � VERIFY WITH OWNER RECESSED LIGHT FIXTURE G� O RECESSED WALL -WASH FIXTURE_! INCANDESCENT FIXTURE VERIFY WITH OWNER SCONCE LIGHT O d� HANGING LIGHT C"D LIGHT FIXTURE CYD Ln LIGHT STRIP W n n n, TRACK LIGHTING �D cc U� UNDER UPPER CABINET O STRIP LIGHTING i y UPL IGHT / W � Q � DOUBLE -HEAD FLOOD FIXTURE 110 v WATERPROOF 20 AMP GRI. OUTLET W 110 v GROUND FAULT I INTERRUPTER OUTLET 220 V. OUTLET P VERIFY HEIGHTS O 110 v FLOOR OUTLET DID, -� SEE OWNER /LOC. � O EVE PLUG co OO 110 v AT CEILING \ — -- --� 110V.OUTLET VERIFY HEIGHTS • N SWITCH qr\ I CT THERMOSTAT o SMOKE DETECTOR/ DESCRIPTION CARBON MONOXIDE DETECTOR COMBO SQUARE FOOTAGE: AC/Dc E. LOWER AC: 1056 ® CHIMES NEW LOWER AC: 1019 C TELEVISION E. UPPER AC: 1010 TELEPHONE TOTAL A/C: 3085 E. GARAGE: 539 E. PORCH: 239 NOTE: ELECTRICAL LAYOUT 15 PROVIDED ONLY AS A GUIDELINE FOR BA51C FEATURES. IT 15 THE 50LE RESPONSIBILITY OF THE BUILDER TO COMPLY WITH ALL TTL AUR: 4163 GOVERNING AUTHORITIES. RUTNERFORD RESIDENCE Drawn Ms/G° AMP 416 RIDGE ROAD Job 11223 �S LOT 6 AND PORTION OF LOT -1 BLOCK CoS� `� * * * ,� ,f, O 1 Date 3/12/26 REPRODUCTION OF RIDGECREST ADDITION % THESE PLANS BY ANY * MEANS IS PROHIBITED * CITY OF CxRAPE V INE REV.*' DATE * THE PLAN FACTORY 0 TARRANT COUNTY * ARLINGTON, TEXAS j� I I I `i j� I `r 817-654-9012 (n designers@planfactory-com NOTE: IT IS THE SOLE RESPONSIBILITY PLAN N 0 � N * CALL DESIGNER TO OBTAIN LLEGAEGAL COPIES # Qv OF THE BUILDER TO VERIFY ALL , y * OF THIS PLAN * * * * O� ASPECTS OF THIS PLAN AND TO }�UT�--�RFORD �� E4 * GAL So ENSURE THAT THIS PLAN MEETS ALL GOVERNING CODES 4 REQUIREMENTS. PG. -1 OF 13 L- J i CONFIRM EXISTING ROOF SLOPE b:12 SHM SIDING \mi l ).1.11. 8' PLATE--- -- ----- ---------------------------------------------\� _ 8' PLATE SIDING BRICKTOMATCHEXISTING:;X,;;;;;;;;;;;;;;;;;;;;;;;;;;;;;; FINISHFLOOR , 1 , 1 , , , , , I , I , I , , , I , , , I , , , I , , , , , , , , , , , , , , , , I , I , I , I , I , I , I , I , I , I , I , , , , , ------- �I,-`--------�� ---------��--,- `----` - - - - - - - - - -- , - il EXIkTING _ _ NEW NEW RIGHT SIDE ELEVATION 1/411= 1'-011 Lm SPECIAL NOTE PROVIDE SAFETY GLAZINGS AS REQUIRED PER SECTION 308 AND EMERGENCY ESCAPE AND RESCUE OPENINGS PER SECTION 310 OF THE INTERNATIONAL RESIDENTIAL CODE FINISH FLOOR C'R AIP VINE CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 06/25/2026 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ATE -FINISH FLOOR -�Lf-------- BRICK TO MATCH EXISTING NEW UMPLANFACTORY.COM L J EXISTING SIDING ----- !-------------------------- -- -FINISH FLOOR EXISTING BRICK EXISTING r. EXISTING NEW LEFT SID 1/411= 1'-011 .- CPLAM- ----- -------------------------------------------------------------------- I 11 I I I 1 I I IL iLLL i Il I I l I I�LI�I I 11 11 I I I I I I I 6:12 W-LLLLI Ill 11 I1LLL I I 1 I� �I II II IIIl II II II1fJ11111 11 IIII II IIII II IIII 11 IIII II IIII IIIIII IIII 1 IIII II II lull Il u,4 l Il IIII III II II l l Il llII'I I I II II II III I I I I_4:12 b P1S.TF-_ -4 HI 4441+I-4I- - - - - I+I-ICI+I++� rl I I I I I -4----------� ---------------------------------------------- --- SIDING NEW NEW REAR ELEVATION 1/411= 1'-011 - - - JI- "-PLATE _EVATION EXISTING ------------------------------------- ---V-PLATE y I I � B EXISTING BRICK SIDING I ------------------------------ -- L --- --- -----------------------------F�NISH�QQI3 RUTHEWORD RESIDENCE 416 RIDGE ROAD EXISTING 5� AMPS LOT 6 AND PORTION OF LOT i BLOCK �0 1 M REPRODUCTION OF RID(3ECRE5T ADDITION THESE PLANS BY ANY MEANS IS PROHIBITED ** CITY OF GRAPEVINE * THE PLAN FACTORY * O TARRANT COUNTY * ARLINGTON, TEXAS 817-654-9012 * U) ` designers@planfactory.com z M Q NOTE: IT IS THE SOLE RESPONSIBILITY CALL THE DESIGNER * * OBTAIN LEGAL COPIES * * Q OF THE BUILDER TO VERIFY ALL -9 * OF THIS PLAN * < ASPECTS OF THIS PLAN AND TO EGA O ENSURE THAT THIS PLAN MEETS ALL L GOVERNING CODES 4 REQUIREMENTS. CD CIO Z 0 E-1 I L I N C\2 (D I CYD LO C0 W I i �D CC) I I � I i Q z W I i 0 Q I i E---q 0 co DESCRIPTION SQUARE FOOTAGE: E. LOWER AC: 1056 NEW LOWER AC:1019 E. UPPER AC: 1010 TOTAL A/C: 3085 E. GARAGE: 539 E. PORCH: 239 TTL AUR: 4163 Drawn Ms/G° Job 11223 Date 3/12/26 REV.* DATE: NA NA PLAN NO. RUTHERFORD PG. S OF 13 L 1/4"=1'-m" NOTES: 1. ROOF P I TCH 9 6:12 U.N.O. 2. ARROWS INDICATE DOWNWARD SLOPE OF ROOF .GRAD VIDE; T F, \ ° 1 S CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 06/25/2026 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. I EXISTING EXI511N6 EXISITNG EXISTING ooO 0 z X W R00FA9RAMNG PLAN NOTES: I. ROOF PITCH 6 6:12 UN.O, I 2. OVERHANG 6 18" FROM EXT. FACE OF FRAME U.N.O. 3. ARROWS INDICATE DOWNWARD SLOPE OF ROOF EXISTING RIDGE 8' PLATE WWW.f=LANf=ACTORY.COM TABLE R80432.1(2)ULTIMATE DESIGN WIND SPEED TO EQUIVALENT SNOW LOAD CONVERSION ULTIMATE EQUIVALENT GROUND SNOW LOAD (psf) WIND SPEED AND EXPOSURE Exposure Wind speed Roof slope (mph) 3:12 4:12 5:12 (6:12 1:12 8:12 9:12 10:12 11:12 12:12 B 115 20 20 20 20 20 20 20 20 20 20 120 20 20 20 20 20 20 20 20 20 20 130 20 20 20 20 20 20 20 20 20 20 LESS140 20 20 20 20 20 20 20 30 30 30 C 115 20 20 20 20 20 20 20 20 30 30 120 20 20 20 20 20 20 20 30 30 50 130 20 20 30 30 30 30 30 30 50 50 LESS140 30 30 50 50 30 30 50 50 50 50 TAE3I_E R804.3.2.10)R00F f ,AFTN 5PAN5a, bl c, d ALLOWABLE SPAN MEASURED HORIZONTALLY (feet -inches) Ground snow load (psf) MEMBER 20 30 1 50 10 DESIGNATION Rafter spacing (inches) 16 24 16 24 16 24 16 162-33 t3 -I1 ll -4 11-�° �'-1" �'-5" T-$° $'-I° 5506I62-43 15'-9' 13'-8 14'-3" I14" Il -4" 9'-3' 5506I62-54 16'-11" 14'-10" 15'-3" 13'-4" 13'-3" II'-T 12'-0" 5506I62-68 18'-2` 15'-10" 16 -5" 14'-4" 14'-3" 2'-5" 12'-11" 8005162-33 1 I6'-4" 13'-4" 3 -1" 9'-0" 9'-6" 8005162-43 19'-1 16'-0" 1 '- " 16 8 13'-i" 13 -4" 10'-10" ll'-5" 8005I62-54 1 22 -9" 19'-II" 20 -1 " IT -11 IT-10" 4'-9" 15'40" 8005162-68 1 24'-T 21'-6" 22'-2' 19'-5" 19'-3° 1 I6'-10" 1 IT-5" 10006I62-43 1 22'-2" 18'-1" 1 18'-10' 1 15'-4° 15'-1" 1 12'-4" 1 12'-I1" 10005162-54 21'-1' 23'-8` 1 24'-6° 1 20'-9- 1 20'-5- 1 16'-8' 1 li'-6" 10005162-68 I 29 -5"' 25 -8" 1 26'-6" 1 23'-2- 1 23 -0- 1 19 -6" 1 20'-6- 12005162-54 1 31'-3° 21-0 1 28-1° 1 22-11" 1 22'-6° 1 18'-4 1 19'4' i1005i61-6S 1 34 -0 15 -S I 30'-S 1 16 -9 1 jr -6 1 11- 1 For 51. 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0-0419 kPa. a. Table provides maximum horizontal rafter spans in feet and inches for slopes between 3:12 and 12.12. b. Deflection criteria: L/240 for live loads and L/180 for total loads. c. Roof dead load = 12 psf. d. Grade 33 ksi steel is permitted to be used for 33 mil and 43 mil thicknesses. Grade 50 ksi steel shall be used for 54 and 68 mil thicknesses—, TNEW a:iz 1 New EX15TING EX15TiNG 8' PLATE 24 ('-i" 10'-6" 11'-3" 12'-T 14'-8" 10'-l" 1 14'-3" 1 IS-6. E-+ O 1 C''J CIO � W I 00 0 I I � w w I o O O NEW I 1 �W NEW RIDGE I DESCRIPTION � I SQUARE FOOTAGE: E. LOWER AC: 105(o I NEW LOWER AC: 1019 EXISTING CHIMNEY E. UPPER AC: 1010 TOTAL A/C: 3085 NEW IV E. GARAGE: 53C3 E. PORCH: 239 — -j -— I 8' PLATE " �� RUTHE O ESIDENGE G ROAD p,MP 5 LOT 6 AND PORTION OF LOT -1 BLOC-< R I DGE GRE ST ADDITION THESE PLANSION BY ANY * MEANS IS PROHIBITED ** CITY OF GRAPEVINE * THE PLAN FACTORY * 0 TARRANT GOUNTY * ARLINGTON, TEXAS * 817-654-9012 (/) 41 designers@planfactory.com * Z Q * NOTE: IT IS THE SOLE RESPONSIBILITY N *% CALL DESIGNER TO * Qv OF THE BUILDER TO VERIFY ALL * OBTAIN LEGAL COPIES .k OFTHISPLAN 9� 'k * O ASPECTS OF THIS PLAN AND TO * 4 * * * /4 LEGAL S ENSURE THAT THIS PLAN MEETS ALL GOVERNING CODES E REQUIREMENTS. TTL AUR: 4163 Drawn Ms�GD Job 11223 Date 3/12/2( REV.*' . DATE: NA NA PLAN NO. RUTHERFORD PG. e OF 13 T I TO EXISTING COLD WATER SOURCE WWWPLANFACTORY.COM PPPVrANOING TU ---� / --�- -�-----1-----T-- - - - i 0 0 — I II , I I II — — — — — — — — — — — — I r--- - - - - -- ---- - - - I I / L I II - - - - - - --- - - - - - - II - t0 EI-Allidr. L S SEWER t0 EXISTING CO/�L� NOT WATER SOUR E �I NA / i II x II j I II / I II j ; II II ----------------------------------- '\) 0 C::1 d J I �- a�•d �z C:d G —U+-) c� a�.., � � x � a� aA � 20 Od ":So 0�, D rn ulQ�b Qn.A O O Q O ul E - Z0a�004 0.4. I / i I I I I W � cc W DESCRIPTION SQUARE FOOTAGE: E. LOWER AC: 1056 NEW LOWER AC:1m19 E. UPPER AG: 1010 TOTAL A/C: 3085 5/8" DIA. PIPE t0 FIXTURES MAN LE11dwL PLUMSIT�IICs IOLM E. GARAGE: 539 LEGEND 1/4' 1 -011 E. PORCH: 239 WH WH 1. ALL ELECTRICAL, PLUMBING AND MECHANICAL WORK DONE ACCORDING SS SANITARY SEWER TO 2021 IRC, 2015 IECC AND 2023 NEC VTR VENT TO ROOF 2. GC HAS THE OPTION TO REROUTE SEWER LINE OR WATER LINE TTL AUR: 4163 OR MECHANICAL DUCT IN ORDER TO SAVE ON COST. THESE PLANS ARE A GENERAL LAYOUT 3. MAIN WATER LINE ENTERING BLDG. IS A 1" LINE THEN BRACHES TO 3/4" 4. ALL SANITARY SEWER LINES TO BE PVC 5. PEX MANIFOLD LOCATED TO BE LOCATED PER PLUMBING CONTRACTOR RUTHERFORD RESIDENCE Drawn Ms/G° AMP / 416 RIDGE ROAD -1 Job 11223 51 S LOT 6 D PORTION OF LOT BLOCK 44 ` Off, 1 Date 3/12/26 OF RI DGECREST ADDITION TRESE PLANTION ** MEANS IS PROHIBITED** �� CITY OF GRAPEVINE REV.* DATE . ` * THE PLAN FACTORY * T,4RRANT COUNTY * ARLINGTON, TEXAS ' ' j� I jam' I `� I `� 817-654-9012 U) designers@planfactory.com Q v NOTE: 1T IS THE SOLE RESPONSIBILITY PLAN NO. N CALL THE DESIGNER TO * Q * OBTAIN LEGAL COPIES k OF THE BUILDER TO VERIFY ALL y� * OF THIS PLAN * * O� * * * * * ASPECTS OF THIS PLAN AND TO I RUTI-��RFORD * /< <EGAL 5� ENSURE THAT THIS PLAN MEETS ALL GOVERNING CODES 4 REQUIREMENTS. PG. 10OF 13 TO EXISTING NOT WATER SOURCE TO EX15TINGx COLD WATER SOURCE L-- r") TO EXISTING „ �— COLD SANITARY SEWER 211 SS 3115 2 md ad hill WINE •. I. ALL ELECTRICAL, PLUMBING AND MECHANICAL WORK DONE ACCORDING TO 2021 IRC, 2015 IECC AND 2023 NEC 2, GC, HAS THE OPTION TO REROUTE SEWER LINE OR WATER LINE OR MECHANICAL DUCT IN ORDER TO SAVE ON COST. THESE PLANS ARE A GENERAL LAYOUT 3. MAIN WATER LINE ENTERING BLDG. IS A 1" LINE THEN BRACHES TO 3/4" 4. ALL SANITARY SEWER LINES TO BE PVC 5. PEX MANIFOLD LOCATED TO BE LOCATED PER FLUM51NG CONTRACTOR U=PLANFACTORY.COM RUTNERFORD RE5IDENGE 416 RIDGE ROAD S� AMP �S LOT (o AND PORTION OF LOT -i BLOCK REPRODUCTION OF >' RIDCxECREST ADDITION ** HESE PLAEANS PPRJOH BIBY TE MIS CITY OF GRAPEVINE * THE PLAN FACTORY * 0 TARRANT COUNTY * ARLINGTON, TEXAS ' * 817-654-9012 'U) ` designers@planfactory.com NOTE: IT IS THE SOLE RESPONSIBILITY nE DESIGNER TO K Qv OF THE BUILDER TO VERIFY ALL LEGAL COPIES THIS PLAN * 0�ASPECTS OF THIS PLAN AND TO ENSURE THAT THIS PLAN MEETS ALL GAL S� GOVERNING CODES 4 REQUIREMENTS. w 0)b >~z �, cd U t '4 N N Ul N�j �+,� a� A x 0 ��� o � � Q) 000w�'w.., v� o0+,os~�a �0a0.0 +-) 0.. Z �W O O O N �F O ;-4Nd N-4 O F_ A 0 0-4. , 0 fx (� o rr:� I F-7 , 0 0 z Ix o LO 06 DESCRIPTION SQUARE FOOTAGE- E. LOWER AC: 1056 NEW LOWER AC: 1019 E. UPPER AC: 1010 TOTAL A/C: 3085 E. GARAGE: 539 E. PORCH: 239 TTL AUR: 4163 Drawn Msl�D Job 11223 Date 3/12/26 REv.# DATE: NA I NA PLAN NO. RUTHERFORD PG. 11 OF 13 WWW.f=LANf=ACTORY.COM T CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 06/25/2026 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVED. j i II j I II I II � II i 0 I I I I 00---- �- - ® 01 I REGISTER - REGISTER REGISTER REGISTER � II II II TO EXISTING HVAC LOCATION ------ II � II , i � n r F0. 1► m 17 FREESTANDING TUB VERIFY SPECS l // \\ GISTER� // \\ _REGISTER i REGISTER I REGISTER 7 REG STE_REGISTER I � I 4-------� 4-� I � 7 REGISTER 2020 NEC 1. ALL ELECTRICAL, PLUMBI ANICAL WORK DONE ACCORDING TO 2(d21 IRC, 2015 IECC AN 2 23 N�rWER 2. GC HAS THE OPTION TO LINE OR WATER LINE OR MECHANICAL DUCT IN ORDER TO SAVE ON COST. THESE PLANS ARE A GENERAL LAYOUT 3. VERIFY ALL DUCT SIZING WITH HVAC CONTRACTOR REGISTER REGISTER RUTHERFORD RESIDENCE 416 RIDGE ROAD S� AMP S LOT 6 AND PORTION OF LOT 7 BLOG< �p 1 REPRODUCTION OF RIDGEGREST ADDITION THESE PLANS BY ANY 4 * MEANS IS PROHIBITED ** 01 G I TY OF GRAPEVINE * THE PLAN FACTORY * 0 TARRANT COUNTY * ARLINGTON, TEXAS 817-654-9012 * (n - ` designers@planfactory.com * Z Q NOTE: IT IS THE SOLE RESPONSIBILITY CALL THE DESIGNER TO Q OF THE BUILDER TO VERIFY ALL OBTAIN LEGAL COPIES k OF THIS PLAN * - ASPECTS OF THIS PLAN AND TO /�* �'� O ENSURE THAT THIS PLAN MEETS ALL eGAL S GOVERNING CODES 4 REQUIREMENTS. N ci y� 0 w _ • ' OF 0 o 4-4 4� ~" D U1 v:z 0: 7;,"0p0.0 ° u a�a+' N0 O HF�00,44 .0 Q O QO O � O c"D LO T � � co DID w w O w m o d- • ` I DESCRIPTION SQUARE FOOTAGE: E. LOWER AC: 1056 NEW LOWER AC:1m19 E. UPPER AC: 1010 TOTAL AIG. 3085 E. GARAGE- 539 E. PORCH: 239 TTL AUR: 4163 Drawn Ms/GD Job 11223 Date 3112126 REV.*' DATE: NA I NA PLAN N O . RUTHERFORD PG. 12 OF 13 SHEATHING VERTICAL, HORIZONTAL OR PLYWOOD SIDING STOPPED ABOVE DECKING CONTINUOUS FLASHING FROM UNDER SIDING TO KERF IN JOISTS OPEN DECKING KERF IN DECK JOISTS FOR FLASHING DRIP T LEDGER BOLTED TO FRAMING JOIST HANGER RABBET BASE OF LEDGER TO COVER SIDING OR FLASH OVER SIDING. .INTERIOR FLOOR STRUCTURE `FRAMED WALL OPEN DECK / WOOD WALL NOTE: Stairs calculated with a 1'— s RAIL / 2 X 2 BALUSTERS aV al OR FLUTED ' .1 / iv 1 X SHOE RAIL FOR " MAXDRJM BALUSTERS 10" NOSING OF Ft. TREAD I WATERPROOF MEMBRANE CONTINUOUS FROM UNDER SIDING TO OUTER EDGE OR CONCRETE REINFORCED LIGHTWEIGHT- CONCRETE DECK PLYWOOD SUBFLOOR SLOPE 114" PER FT. HEADER JOIST BOLTED TO FRAMING NOTE: IF RAIL IS SOLID, SLOPE CONCRETE TO SCUPPERS FROM ALL DIRECTIONS LIGHTWEIGHT -CONCRETE DECK @ WALL Requirements Baluster spacing (clear) 4" may - Clearance above nosing 8'8" min. Landing length do width equal to stair width. Landing railing 36 to 42 above landing. Nosing 1 1/8". Rise 7. 75" mA rimum Stair railing 30 to 34 " above nosing. Tread 10" min. 1lidth of stairs 38" min. in clear VNI 1 1/8 PART. BD. TREADS GLUED & SCREWED Provide Min. 38" 1/2" PLYWOOD wldth at stairways F 3) 2 X 12 STRINGERS INGERS 5/8' TYPE "JC GYPSUM BD. SECTION TYP. UNDER STAIRS O STAIR DETAIL Roof Roofing: Customer Choice Sheathing: 1/2' CDX Min. Marked for 24" spans. Note No vents in protected area - Block all horozonal Panel edges. Gypsun board must be Balled • 7 O.C.. F1berk*mrd--l/2' for Note: Nails 3/4" min. from edge TYPICAL VALLEY DETAIL Garage Wall Use 5/8" Type "X" Gyp BD. on all CLGS, walls, & exposed members. ff �p /,ems CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 06/25/2026 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. 1 1/2" INTERIOn GYPSUM SHEATHING & FINISH AS Liw BRICK VENEER WITH MASONRY ANCHORS DBL. 2X4 TOP PLATE AT 16" O.C. VERT. _ \& 24" O.C. HORIZ. STUCCO SCALE: 1/2" = l'-0" 2x4 STUDS ® 16" O.C. 1/2" ASPHALT -IMPREGNATED SHEATHING/PLYWOOD/OR GYPSUM BOARD T-PLY PAPER, 1 OR 2 LAYERS 1" GALVANIZED STEEL MESH (MIN. 20 GA.) OR 2.5 EXPLANDED METAL LATH MIN. 3/8" STUCCOBASE STUCCO FINISHE WALL SECTION OPENINGS ARE PROHIBITED ' TYPE X GYP BOARD TO MEET AN51/UL 26: ABV. FINISH SOFFIT MATERIAL ' HARDIE 5OFF IT AS SELECTED UNDER GYP. BOARD 1 HOJfR FfRE fR,47ED OVEfRHANC DETAIL 1/2' =1'-0' INSULATION AS or �. �.� ,�.,� _ ROOF AS .w &ii m4L ON MANUFACPUER =10MMENDED - UNDERLAYMENT 2X4 FIREBLOCK aLa LLA - 2X�, RAFTERS O STUDS AT MID-HII�r,. - 24 O.C. OR AS _ APP D BY ENGINEER 1/2" INTERIOR GYPSUM - SHEATHING & FINISH - 2X6 JOISTS O 16" AS Lia) - QN CENT. OR AS APP D BY ENGINEER INSULATION AS 15 LB. FELT FLASHING TURN UP 12" ON 2X4 SOLE PLATE WITH - INSIDE OF SHEATHING 1/2" ANCHOR BOLTS FROM CONCRETE AT 4' - 0" O.C. / WEEP HOLES O 4' O.C. V FLOOR 0 0 0 9 \ SEE FOUNDATION PLAN TYPICAL WALL SECTION (ONE STORY) N.T.S V VL�IGIJ 2X4 NAILER BETwlcpvN JOISTS / 3/4" X 24" PLYWOOD VENT BAFFLE / 2X4 NAILERS GALV. METAL DRIP -� iX4 TRIM \ 1X8 FASCIA 6" X, 16" SOFFIT VENT O 8 -0" O.C. 3/4" EXT. PLYWOOD SOFFIT HIP CORNICE N.T.S INSULATION AS Jr L%.,jjI jL4) ROOF D III SULA WWW.IOLANf=ACTORY.COM DBL. TOP PLATE HEADER (REFER TO 7/16" OSB ARCH FRAMING PLAN) w� ti 2x BLOCKING AS NEEDED .� TRIMER STUDS TYP. ARCH DETAIL SCALE: 1/4" = l'-0" TOP CHORD OF RAFTER FIRE CALK JOINTS AT DECK 5/8" TYPE X GYP. BD. FIRE TAPE ALL JOL\iTS FIRE CALK JOP ITS AT CEILING 5/8" TYPE X GYP. / T CHORD OF RAFTER R BD. CEILING RAF ATTIC 51 10KE FAFPT I T I ON 1/2' =1' -0' 2X6 CIELING JOIST OR TRUSS BOTTOM MEMBER EL XX t 93 1PLATE LINE \\;)BL. 2 X 6 TOP PLATE 1/2" u� 9- inuOR GYPSUM SHEATHING & FINISH AS u a6 2 X 6 FIREBLOCK BETWEEN or .►. STUDS AT MID -HEIGHT 1/2" INTERIOR GYPSUM SHEATHING & e +t n AS or .&, 2 X 6 SOLE PLATE WITH 1/2" ANCHOR BOLTS FROM CONCRETE AT INSULATION AS ortwLeLi#i� 4' - 0" O.C. Mu,nj�w FLOOR TYPICAL N.T.S. 0 0 III �,1 —III �I dr= 0 O „I I �_ \ SEE FOUNDATION PLAN WALL SECTIQN (TRIO STORY) NOTE: IT 15 THE SOLE RESPONSIBILITY OF THE BUILDER TO VERIFY ALL ASPECTS OF THIS PLAN AND TO ENSURE THAT TH15 PLAN MEETS ALL GOVERNING CODES 4 REQUIREMENTS. DESCRIPTIONI Drawn Job Date PLAN N0. DETAIL PG. I OF I GRAM INE CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 06J25/2026 BY: ARNOLDO RAMIREZ TSBPE:1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF QUAY. ALL CHANGES MUST BE APPROVED. L,.E. L-------------------------------------------------------------------------------------------- ' I i 0 2 ,)A, -'I,, A"-cs � 2 I , I — — — —— a , 1 I 1 I I" I� I� 1- 1= L o ==*r ;= 4 N W i W ADD TION jL /-0 1.� . SCALE: 1" =2O L-OT (o AND OF _OT i BLOCK 1 RIDC-cECREST ADDITION � CITY OF GRAPE V NE / TARRANT COUNTY C 2 2 3 1�,A ✓ATE :�� A\1 FAC 7 OR1' DA�E: 1/i9/2� NA - IT 5HALL BE THE FJLL RE5FON513ILI7Y O� -HE 3JI.DER TO ✓ERIFY A-� A5FEC-5 0" �H5 FLAN AND 4DJJ5* !F REOJIRED ct') Single Family House Energy Report Project Details Project Name: THERFORD_416 RIDGE ROAD Builder Name: Builder Phone: Justin Sobczak 817-688-3253 Builder Email: "@triplecheckinspections.com Address: 416 RIDGE ROAD City: GRAPEVINE County: TARRANT Zip: 76051 Certificate #: 1390323 Date Issued: 4/16/2026 Notes: Emissions Reduction 2 %Above Code This single family residential project was found to be in compliance with the performance measures described in the 2015 IECC as calculated by the Energy Systems Laboratory, a division of the Texas A&M Engineering Experiment Station 77 using IC3 version 4.9.1 ENERGY SYSTEMS LABORATORY TEXAS A&M ENGINEERING EXPERIMENT STATION The values produced are generated by the DOE-2 building energy analysis program. These values do not constitute a guarantee of actual energy usage by ESL or TEES. IC3 performs the hourly annual energy calculation in accordance with the International Energy Conservation Code Section R405, Simulated Performance Alternative. IC3 does not address the adequacy of the sizing of the heating/ cooling system. NOx: 0 lbs. sox: 0 lbs. Authorized Signature: CO2e: 464 lbs. IC3International CODE COM ■ - ■ COMPLIANCE M ■CALCULATOR Version 4.9.1 Copyright 2026 Energy Systems Laboratory 11223_RUTHERFORD_416 RIDGE F Page 1 of4 General Number of Bedrooms: 5 Wall Cavity Insulation: R- 13 Wall Continuous Insulation: R- 0 Windows Roof Orientation: North SHGC: 0.25 U-Factor: 0.22 Cladding Type: Composite Shingl( Radiant Barrier: No Sealed Attic: No Roof Insulation: R- 38 Attic Area: 1019 Cathedral Ceiling Area: 0 Flat Roof Area: 0 Wall Area Next to Attic: 0 Foundation Foundation Type: Slab on Grade Foundation Insulation: R- 0 WO SEER: 16 SEER2: N/A Tonnage: 4.00 Project Information Structural Floor 1 Exterior Finish: Brick Stud Type: 2 x 4 Stud Spacing: 16 Mechanical Blower Door Test: 3 Ventilation Type: Balanced Ventilation Rate: 82 Ventilation Operation: 24 Fan Power: 0.01 Fraction Outside: 0.5 Duct Tightness Test: 66 Supply Duct Insulation: R- 8 Return Duct Insulation: R- 8 Heating Heating Type: Heat Pump Heating Efficiency: 8.2 HSPF Water Heater Water Heater Type: Electric Energy Efficiency: 0.96EF Tank Size: N/A Burner Capacity: N/A First Hour Rating: N/A Gallons Per Min: N/A Floor Area: 1019 Floor Wall Height: 8 Front Side Length: 85 Right Side Length: 43 Front Side Window Area: 35 Right Side Window Area: 30 Front Side Shading: 12 Right Side Shading: 12 Back Side Length: 85 Left Side Length: 43 Back Side Window Area: 93.25 Left Side Window Area: 19 Back Side Shading: 12 Left Side Shading: 12 Floor 2 Floor Area: 1010 Area over Unconditioned: 0 Floor Wall Height: 8 Right Side Length: 26 Front Side Length: 42 Front Side Window Area: 0 Right Side Window Area: 0 Front Side Shading: 12 Right Side Shading: 12 Back Side Length: 42 Left Side Length: 26 Back Side Window Area: 0 Left Side Window Area: 0 Back Side Shading: 12 Left Side Shading: 12 1C3MInternational ■CowCo ri ht 2026 Ener S stems Laborator COMPLIANCE Version 4.9.1 pY g gY Y Y 11223_RUTHERFORD_416 RIDG Page 2 of4 ■CALCULATOR Estimated Annual Energy Usage Proposed Peak Electric Demand: 9.0 Proposed Total Area Lights: 1231 Energy Usage Category Proposed Design Standard Reference Gas (therms) Electric (kWh) Gas (therms) Electric (kWh) Pumps and Miscellaneous 0 59 0 59 Ventilation Fans 0 908 0 891 Mechanical Ventilation 0 0 0 258 Space Cooling 0 2140 0 2169 Space Heating 0 2667 0 2609 Domestic Hot Water 0 3605 0 3605 Site Energy 0 9379 0 9591 * Conversion factors: Site to source factor: 3.16 for electric or 1.1 for natural gas (IECC 2015 R405.3) Unit: 1 MMBtu = 10 therms or 1 MMBtu = 293.1 kWh IC3International (CODE Copyright 2026 Energy Systems Laboratory 0: � Version 4.9.1.gY Y Y 11223_RUTHERFORD_416 RIDGE F Page 3 of 4 Disclaimer The International Code Compliance Calculator (IC3) software and accompanying documentation are developed and maintained by the Energy Systems Laboratory (ESL) at the Texas A&M Engineering Experiment Station. The IC3 tool is provided as a free public service to support energy code compliance for residential buildings in Texas. However, the ESL makes no warranties, express or implied, regarding the accuracy, completeness, reliability, or suitability of the software or manual for any particular purpose. Use of the IC3 software and any data or reports generated by it is at the user's sole risk. The ESL, Texas A&M University System, and its affiliates shall not be held liable for any direct, indirect, incidental, or consequential damage arising from the use of this software or reliance on the information it provides. Users are responsible for verifying that all project data and outputs meet applicable local, state, and federal code requirements. This software is intended to assist in evaluating residential energy performance based on standardized inputs. It does not replace the need for professional design services, engineering judgment, or review by local building officials. Users are strongly encouraged to consult the appropriate authority having jurisdiction (AHJ) to ensure full compliance with current energy codes. CODE OM C IC3 • • ■ ■OMPLIANCE Version 4.9.1 Copyright 2026 Energy Systems Laboratory 11223_RUTHERFORD_416 RIDG Page 4 of4 ■ ■CALCULATOR Qty 16 1 WINDOW SCHEDULE Project Address: 416 Ridge Rd Call Type Size Exact Size Location Series U-Factor SHGC Single Hung 3650 41 1/2" x 59 1/2" Primary Ste. B21 Series 0.29 Single Hung 3050 35 1 /2" x 59 1/2" Primary Ste. B21 Series 0.29 Picture Window 4040 47 1 /2" x 47 1 /2" Primary Bath B21 Series 0.27 0.22 0.22 0.23 3 Single Hung 3060 35 1/2" x 71 1/2" Living Room B21 Series 0.29 0.22 1 Single Hung 3036 35 1 /2" x 41 1/2" Kitchen B21 Series 0.29 0.22 1 Single Hung 2636 29 1/2" x 41 1/2" Utility Window Specifications: • Series: B21 Tilt Sash • Low- E 366/C lea r Glass • Argon Filled • 3-1/4" Jamb Depth • Half Screens • No Muntin Bars Maximum U-Factor: 0.29 Maximum SHGC: 0.23 SPECIAL NOTE PROVIDE SAFETY GLAZINGS AS REQUIRED PER SECTION 308 AND EMERGENCY ESCAPE AND RESCUE OPENINGS PER SECTION 310 OF THE INTERNATIONAL RESIDENTIAL CODE B21 Series 0.29 0.22 GRAP N NE CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 06/25I2026 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVED. GRAHAM -MARTIN, LTD. P.O. Box 535097 Grand Prairie, TX 75053-5097 (972) 647-1025 April 16, 2026 The Plan Factory 4303 South Bowen Rd. Ste. 117 Arlington, TX 76016 Re: Lot 67 Block 1 416 Rridge Road Ridgecrest Addn, Grapevine Plan: Pier and Beam Addn G M L# 055940 To Whom it May Concern: Engineering Consultants Texas Reg. Eng. Firm F-8336 CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANYWORKINCONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TINES. 06f252026 BY: ARNOLD0 RAMIR EZ TSB PE: 13898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLYTO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVED. The foundation for the above referenced location has been designed and evaluated in accordance with the latest recommendations as set forth by the American Concrete Institute (ACI code 318-89). It has also been designed in accordance with the 2015, 20181 2021 and 2024 International Residential Codes, the 2015, 2018, 2021 and 2024 International Building Codes, the WRI/CRSI-81 Design of Slab -on -Ground Foundation and standard engineering practices. The pertinent soils information utilized in the design was assumed from general soils classifications obtained from the following soil survey, published by the United States Department of Agriculture's Soil Conservation Service: Source: Soil Survey of Tarrant County, Texas Qa: 1500 PI: 30 PVR: 2.0" Sincerely, GRAHAM -MARTIN, LTD Bill Graham, P.E. Principal REVISIONS BY REVISED 00/23/2028 BG CLOUDE 7' - 8' 6'- 10" 24'-8" FIELD VERIFY 7'-6" 6'-1 ; 3'-10" .3'-1091 _.6" C Q J OB o ' �• �r -- — — — — — — — — — -- Rr ------------`�(!® \ �^ >II C� n i > > o I I Oil I I OE F- - - - - - - - - - - - - - �►. I ON H IJ o10'-6" TYP UH- I I BLD E TO ENSURE THAT EXISTING EXTERIOR ��A[ Q '7 FLO,: R JOIST LOADINGS I > w N U M I a- N EXISTING F,10UNPATION "Co Of SYSTEM a 0Ld ® LO I — I > I - °' I I -- L----------------------- �t ►� OE -0; 3 PIER SPACES @ 5'-10" O.C. I 20'-0" I L---------------------------------- NEW FLOOR PIER LAYOUT PLAN 7' - 3„ 3'-6" a o 6r ---------- 9 --,or ------------ 0 -Jim I- I� > I I I a I I I I I CA) E CA� x iL Y is it itY 3 Y it itL-- ----- ---� L----------J■ ■�■ ■�■�■� ww T T w A ,-2" a 47,-7„ U ONU _ BLDR TO ENSURE THAT EXISTING EXTERIOR M `_ (A� E A ,, CIENT P T W �L i" _ J,L �L Y _ Y_Cx it x FLOOR JOIST LOADINGS ■� ■ ■ ■ ■ � ■ � ■ T T T T T T T T T T T EXISTING FOUNDATION SYSTEM E \Zl! IL Y Y = AL - AL i 0 OE NEW FLOOR FRAMING LAYOUT 0 N 0 t\ N I DO 0 N I 00 0 CONCRETE PIER NOTES: A. ALL PIERS SHALL BE 12" DIA. REIND. W/ (3) - #5 VERT EXTEND REBAR INTO CONC GRADE BEAM AS SHOWN. ALL PIERS SHALL BED A MINIMUM OF 8' BELOW ALL FILL SOILS. FLOOR FRAMING NOTES: A. (3) - 1 J" X 5 /2" LVL MAIN GIRDER. SPLICE MAIN GIRDERS OVER PIERS ONLY. B. ALL FLOOR JOISTS ARE 2 X 6'S ® 16" O.C. � C. DBL"REFERS TO DOUBLE JOIST UNDER WALL ABOVE. D. UNTREATED LUMBER SHALL NOT COME IN DIRECT CONTACT W/ CONCRETE. E. AS GRAHAM - MARTIN, LTD. TOOK NO PART IN THE DESIGN / CONSTRUCTION OF THE EXISTING FOUNDATION OR STRUCTURAL FRAME, WE OFFER NO WARRANTY EITHER EXPLICIT OR IMPLIED WITH REGARD TO ITS FUTURE PERFORMANCE. NOTE: THIS FOUNDATION SYSTEM HAS BEEN DESIGNED NOTE: UNTREATED LUMBER SHALL NOT CONTACT DIRECTLY AS A GROUND -SUPPORTED PIER AND BEAM PER THE W/ CONCRETE. A MOISTURE BLOCK MUST BE PROVIDED INSTRUCTIONS OF THE PROJECT OWNER/BUILDER. BOTH BTWN UNTREATED LUMBER FRAMING AND CONCRETE SURFACES 9:tell] 11/l:la/:\J\;4DIY:F.111■IM01KEQ1111JZ117140181► 0-10DEVI0 `. EXTREMELY SUSCEPTIBLE TO DISTRESS AS A RESULT OF SEASONAL SOIL MOVEMENTS. OWNER / BUILDER IS RESPONSIBLE FOR KEEPING SEASONAL SOIL MOVEMENTS TO LESS THAN 1". GRAHAM - MARTIN, LTD. IS NOT NOTES: RESPONSIBLE FOR DISTRESS TO THE FOUNDATION OR SUPERSTRUCTURE AS A RESULT OF SEASONAL SOIL 1) All beams shall be 12 " W x 26 " D. MOVEMENTS IN EXCESS OF 1" OR ANY INDUCED STRESSES 2) At the clients request, this design is FROM THE EXISTING HOMES. CRAP VANE. r3 . - •'T F. \ '1 S q� CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 06/25/2026 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVED. PROVIDE SIGNED AND SEALED LETTER FROM REGISTERED ENGINEER CONFIRMING SITE INSPECTION AND APPROVAL OF PIER INSTALLATION WHEN WORK IS COMPLETE ALL BEAMS SHALL BED A MINIMUM OF 6" INTO UNDISTURBED SOILS OR PROPERLY COMPACTED FILL SOILS BUILDER TO VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO CONSTRUCTION OF THIS SLAB DRAWING SCALE: 3/16" = 1'-0" NOTES: 1. #5 CORNER BARS SHALL BE INSTALLED AT ALL BEAM INTERSECTIONS. CORNER BARS SHALL LAP BEAM BARS 20" MINIMUM. 2. ALL CONCRETE SHALL HAVE A MIN. 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI. ADMIXTURES CONTAINING CHLORIDES, FLOURIDES, SULPHITES, NITRATES AND FLYASH ARE NOT PERMITTED. 3. ALL REINFORCING STEEL SHALL BE NEW BILLET STEEL CONFORMING TO A.S.T.M. A-615 GRADE 60 EXCEPT #3 BARS MAY BE GRADE 40. ALL BEAMS SHALL BE 20" MINIMUM. 4. VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. 5. CARE SHOULD BE TAKEN TO MAINTAIN AN EVEN MOISTURE CONTENT AROUND THE SLAB SO THAT DIFFERENTIAL SOIL MOVEMENTS ARE LIMITED. GRADING AND DRAINAGE SHOULD BE PROVIDED SO THAT WATER DOES NOT COLLECT NEAR OR UNDER THE SLAB. HEAVY VEGETATION (SUCH AS TREES) WITHIN 10' OF THE PERIMETER MAY CAUSE EXCESSIVE DESICCATION OF THE SURROUNDING SOILS. 6. ALL FILL MATERIALS SHALL HAVE A PLASTICITY INDEX OF 20 OR LESS AND MUST BE COMPACTED TO A MIN. 95% OF STANDARD PROCTOR DENSITY, MAINTAINING MOISTURE AT 3% TO 4% ABOVE OPTIMUM, UNLESS SPECIFIED OTHERWISE BY A GEO-TECHNICAL ENGINEER. COMPACTED FILL SHALL EXTEND A MINIMUM OF 5'-0" BEYOND THE FOUNDATION PERIMETER AND SHALL CONFORM TO ASTM D698 AND FHA SHEET 79G. 7. ALL BEAM SOFFITS MUST BE FOUNDED A MIN. OF 6" INTO UNDISTURBED SOIL OR PROPERLY COMPACTED FILL, UNLESS SPECIFIED OTHERWISE BY A GEO-TECHNICAL ENGINEER. BEAM DEPTHS MAY BE INCREASED TO A MAX. OF 30" TO MEET DEPTH REQUIREMENTS WITHOUT ADDITIONAL REINFORCING. 8. TRENCHES FOR PLUMBING LINES SHALL NOT BE LOCATED DIRECTLY UNDER (PARALLEL TO) GRADE BEAMS. PLACE PLUMBING LINES PERPENDICULAR TO BEAMS. PLACE BACKFILL IN CONFORMANCE WITH ABOVE COMPACTION REQUIREMENTS. 9. PIERS MAY BE USED ONLY WHEN SPECIFICALLY DESIGNED AND DETAILED ON PLANS. PARTIAL PIERING OF FOUNDATION IS STRICTLY PROHIBITED. 10. REINFORCING STEEL SHALL BE SUPPORTED AT 36" ON CENTER MAX. CONCRETE PLACEMENT SHALL BE DONE IN SUCH A MANNER AS TO INSURE THAT THE ALIGNMENT OF THE REINFORCING STEEL DOES NOT CHANGE. 11. REFER TO DESIGN LETTER WHICH ACCOMPANIES THIS PLAN FOR SOILS INFORMATION UTILIZED IN THE DESIGN OF THIS FOUNDATION. 12. FRAMEWORK ABOVE THE FOUNDATION SHOULD BE DESIGNED TO RESIST DIFFERENTIAL MOVEMENTS ASSOCIATED WITH THE EXISTING PLASTIC SOILS. THIS SHOULD INCLUDE EXPANSION JOINTS IN THE BRICK VENEER. 13. MODIFICATION OF THIS STRUCTURAL DESIGN WITHOUT PRIOR WRITTEN CONSENT OF GRAHAM - MARTIN, INC. WILL VOID ANY RESPONSIBILITY BY GRAHAM - MARTIN, INC. WITH REGARD TO LIABILITY ASSOCIATED WITH THE PERFORMANCE OF THIS ENGINEERED FOUNDATION. based on general Information obtained from the soil survey of TARRANT County, published by the United States Dept. of Agriculture, Soil Conservation Service. Design soil parameters: Qa = 1500 (minimum, psf) PI = 30 (maximum) PVR = 2.0" (maximum, inches) The client is responsible for verifying that the in -place soils conditions at the time of construction do not exceed the above limitations. The above soil bearing capacity (Qa) is assuming that all beams will be founded into undisturbed soil or properly compacted fill. If this foundation does not show piers and the bearing capacity does not meet the above requirements, contact our office for pier design requirements. A geo-technical report, although requested by GML, was not provided by the client for the purpose of designing this foundation. A site -specific report would provide more information that may be necessary for an appropriate design at this site. The project owner should be made aware of the limitations of the soils information and this design. We assume no responsibility, whatsoever, for the accuracy of the soils information obtained from the above referenced soil survey and make no representation that it is appropriate for the actual conditions at this site. MODIFICATION OF THIS DESIGN WITHOUT PRIOR WRITTEN CONSENT FROM GRAHAM -MARTIN, LTD. WILL VOID ANY RESPONSIBILITY WE MAY HAVE WITH REGARD TO ANY LIABILITY ASSOCIATED WITH THE PERFORMANCE OF THIS ENGINEERED FOUNDATION. W Z Z 0 � 0 a o_ Y U m U 00 0 Q c Qam�a �W Z W WN ^0Ld OF Tco F'�9'f` = J p c° 0 • � a _J ItOf w • BILL GRAHAM — 04/16/2E ..67 99.. �0- sari: 1 Fssc —E3c - /ONAt — 055940 sm S1.0 REVISIONS BY NEW SHEET 06/23/2026 BG ❑ (3) - 1 I" X 5 1" LVL ❑ MAIN GIRDER 2 X 6 FLOOR JOISTS El�® 16" O.C. DBL FLR JOIST UNDER EXT WALL$ ❑ t� 3 X 6 TREATED SOLE PLATE II II I II " ---t2" WIDE (3) - #5 CONT. TOP AND BOTTOM *=.t i 12" DIA PIER REINF. I o W/ (3) - #5 VERT EXTEND 16" INTO GRADE BM AS SHOWN SEE PLAN FOR PIER LOCATIONS A SECTION 6" EMBED 24" MIN (2) - #5 DOWELS X 24" L DRILL & EPDXY INTO EXISTING GRADE BEAM TOP & BOTTOM (4) DOWELS TOTAL 24" (3) - 1 I" X 5 J" LVL MAIN GIRDER 2 X 6 FLOOR JOISTS R ® 18" O.C. DBL FLR JOIST �{ UNDER EXT WALL— �_ -2 X 6 TREATED SOLE PLATE II II �r2" WIDE (3) - #5 CONT. I I I I TOP AND BOTTOM—#:o-=-� 12" DIA PIER REINF. I o m m W/ (3) - #5 VERT m ca:j EXTEND 16" INTO GRADE V2 w BM AS SHOWN w a. ON: a. oc Ga a SEE PLAN FOR Ga 0 r.1 PIER LOCATIONSmm awa awa SECTION (3) - #5 CONT. TOP PkOOK 12" ® DISCONTINUOUS END G SECTION N I N 1 (3) - #5 CONT. BOTTOM EXTEND PIER REINF. 16" INTO GRADE BEAM TYP. W 18 X 35 EXTEND TOP OF STEEL STEEL BM -I\ BM INTO WALL ABOVE 2 X 6 CEILING JOISTS ® 16" O.C. 2 X 10 EXISTING FLOOR JOISTS 4" T.S. COL W/ " WALL THK 6" SQ X I" THK STEEL BASEPLATE. ATTACH TO EXISTING CONC BM W/ (4) - j" X 6" L WEDGE ANCHORS TIT -- EXISTING CONC GRADE BM /(2) - #4 TOP BARS (2) - #4 TRANSVERSE FROM PIER BARS X 16" L oI °4 ' '4 #3 STAKES AS v I NECESSARY I.aa. G FOOTER 18" ° ° WIDE f �I (I I a T coM . M :j (2) - #4 BOT BARS w rk: FROM PIER 12" DIA PIER a 11_ a REINF. W/ (4) a a - #4 VERT r .XD (9 SECTION 2 X 8 FLOOR JOISTS `® 18" O.C. R / RIM JOIST MATERIAL-12 t' 6 TREATED SOLE PLATE II II II " II — t2" WIDE (3) - #5 CONT. I II 1 1 TOP AND BOTTOM 12" DIA PIER REINF. I 0 W/ (3) - #5 VERT C EXTEND 16" INTO GRADE BM AS SHOWN -f w 0» o SEE PLAN FOR PIER LOCATIONS \ n C SECTION NOTE: THIS FOUNDATION SYSTEM HAS BEEN DESIGNED AS A GROUND -SUPPORTED PIER AND BEAM PER THE INSTRUCTIONS OF THE PROJECT OWNER/BUILDER. BOTH SHOULD BE AWARE THAT THIS FOUNDATION SYSTEM IS EXTREMELY SUSCEPTIBLE TO DISTRESS AS A RESULT OF SEASONAL SOIL MOVEMENTS. OWNER / BUILDER IS RESPONSIBLE FOR KEEPING SEASONAL SOIL MOVEMENTS TO LESS THAN 1 ". GRAHAM - MARTIN, LTD. IS NOT RESPONSIBLE FOR DISTRESS TO THE FOUNDATION OR SUPERSTRUCTURE AS A RESULT OF SEASONAL SOIL MOVEMENTS IN EXCESS OF 1" OR ANY INDUCED STRESSES FROM THE EXISTING HOMES. APPLY BONDING AGENT TO EXISTING FACE PRIOR TO NEW CONC POUR --", OUR #3 ® 111" O.C.E.W. EXISTING CONC - - - - - - - - GRADE BM �I I #4 DOWELS X 14" L DRILLED & EPDXY 0 K 18" O.C. UNDISTURED * 6" SOILS OR PROPERLYN MBED. COMPACTED FILL SOILS (2) - #5 CONT. TOP & BOTTOM 12" Al�SECTION W 18 X 35 EXTEND TOP OF STEEL STEEL BM BM INTO WALL ABOVE 2 X 6 CEILING JOISTS ® 16" O.C. 2 X 10 EXISTING FLOOR JOISTS d" T.S. COL W/ }" WALL THK 6" SQ X I" THK STEEL BASEPLATE. ATTACH TO EXISTING CONC BM W/ (4) -" X 6" L WEDGE ANCHORS 12" #3 ® 16" I EXISTING CONC GRADE BM P(:21"- I #4 DOWELS X 14" LDRILLED & EPDXY18" O.C.— #5 CONT. 6" TOP &BOTTOM (2) - #4 TRANSVERSE MBED_ BARS X 16" L s s FROM - TOP BARS FROM PIER a 4 e #3 STAKES AS NECESSARY FOOTER 18" e ° WIDE f l 11 i 4.0°.. T coM . v� (2) - #4 BOT BARS n e w FROM PIER 12" DIA PIER a a REINF. W/ (4) caoa - #4 VERT 9 SECTION z 04 N /_#3 15 11 O.C.E.W. I UNDISTURED " SOILS OR PROPERLY COMPACTED FILL SOILS I I 1 1 (3) - #5 CONT. TOP & BOTTOM 12" (j) SECTION 2 X 6 FLOOR JOISTS R ® 16" O.C. DBL FLR JOIST UNDER EXT WALL. �-2 X 6 TREATED SOLE PLATE II II I .II I II `i' � II " t2" WIDE (3) - #5 CONT. TOP AND BOTTOM f �I 12" DIA PIER REINF. I o W/ (3) - #5 VERT co cn EXTEND 16" INTO GRADE BM AS SHOWN w ao SEE PLAN FOR PIER LOCATIONS SECTION NOTE: UNTREATED LUMBER SHALL NOT CONTACT DIRECTLY W/ CONCRETE. A MOISTURE BLOCK MUST BE PROVIDED BTWN UNTREATED LUMBER FRAMING AND CONCRETE SURFACES a 2 X 8 FLOOR JOISTS ❑ �® 18" O.C. ❑ 5Z RIM JOIST MATERIAL' ❑ 2 X 6 TREATED SOLE PLATE II II II N II �22" WIDE (3) - #5 CONT. I �I TOP AND BOTTOM— o=�i 12" DIA PIER REINF. I o W/ (3) - #5 VERT m m EXTEND 16" INTO GRADE BM AS SHOWN w ao SEE PLAN FOR PIER LOCATIONS r-4 W SECTION /_#3 ®18" #3 ®18" O.C.E.W. O.C.E.W. I I I I I I I I I #3 STAKES AS I UNDISTURED " N UNDISTURED SOILS OR PROPERLY SOILS OR PROPERLY NECESSARY I COMPACTED FILL COMPACTED FILL SOILS SOILS I I I I (2) - #5 CONT. 1 1 TOP & #BOTTOM TOP &BOTTOM 1 1 12" 12' PROVIDE SIGNED AND SEALED LETTER FROM REGISTERED ENGINEER CONFIRMING SITE INSPECTION AND APPROVAL OF PIER INSTALLATION WHEN WORK IS COMPLETE SECTIONSECTION 2 X 6 FLOOR JOISTS ® 16" O.C. 6 CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 06/25/2026 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVED. ALL BEAMS SHALL BED A MINIMUM OF 6" INTO UNDISTURBED SOILS OR PROPERLY COMPACTED FILL SOILS BUILDER TO VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO CONSTRUCTION OF THIS SLAB (3) - 1J"X5J"LVL MAIN GIRDER 12" DIA PIER REINF. W/ (3) - #5 VERT SEE PLAN FOR PIER LOCATIONS 2 X 6 FLOOR JOISTS �® 16" O.C. 1. 1 �2 X 6 TREATED SOLE PLATE SECTION NOTES: 1. #5 CORNER BARS SHALL BE INSTALLED AT ALL BEAM INTERSECTIONS, CORNER BARS SHALL LAP BEAM BARS 20" MINIMUM, 2. ALL CONCRETE SHALL HAVE A MIN. 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI. ADMIXTURES CONTAINING CHLORIDES, FLOURIDES, SULPHITES, NITRATES AND FLYASH ARE NOT PERMITTED. 3. ALL REINFORCING STEEL SHALL BE NEW BILLET STEEL CONFORMING TO A.S.T.M. A-615 GRADE 60 EXCEPT #3 BARS MAY BE GRADE 40. ALL BEAMS SHALL BE 20" MINIMUM. 4. VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. 5. CARE SHOULD BE TAKEN TO MAINTAIN AN EVEN MOISTURE CONTENT AROUND THE SLAB SO THAT DIFFERENTIAL SOIL MOVEMENTS ARE LIMITED. GRADING AND DRAINAGE SHOULD BE PROVIDED SO THAT WATER DOES NOT COLLECT NEAR OR UNDER THE SLAB. HEAVY VEGETATION (SUCH AS TREES) WITHIN 10' OF THE PERIMETER MAY CAUSE EXCESSIVE DESICCATION OF THE SURROUNDING SOILS. 6. ALL FILL MATERIALS SHALL HAVE A PLASTICITY INDEX OF 20 OR LESS AND MUST BE COMPACTED TO A MIN. 95% OF STANDARD PROCTOR DENSITY, MAINTAINING MOISTURE AT 3% TO 4% ABOVE OPTIMUM, UNLESS SPECIFIED OTHERWISE BY A GEO-TECHNICAL ENGINEER. COMPACTED FILL SHALL EXTEND A MINIMUM OF 5-0" BEYOND THE FOUNDATION PERIMETER AND SHALL CONFORM TO ASTM D698 AND FHA SHEET 79G. 7. ALL BEAM SOFFITS MUST BE FOUNDED A MIN. OF 6" INTO UNDISTURBED SOIL OR PROPERLY COMPACTED FILL, UNLESS SPECIFIED OTHERWISE BY A GEO-TECHNICAL ENGINEER. BEAM DEPTHS MAY BE INCREASED TO A MAX. OF 30" TO MEET DEPTH REQUIREMENTS WITHOUT ADDITIONAL REINFORCING. 8. TRENCHES FOR PLUMBING LINES SHALL NOT BE LOCATED DIRECTLY UNDER (PARALLEL TO) GRADE BEAMS. PLACE PLUMBING LINES PERPENDICULAR TO BEAMS. PLACE BACKFILL IN CONFORMANCE WITH ABOVE COMPACTION REQUIREMENTS. 9. PIERS MAY BE USED ONLY WHEN SPECIFICALLY DESIGNED AND DETAILED ON PLANS. PARTIAL PIERING OF FOUNDATION IS STRICTLY PROHIBITED. 10. REINFORCING STEEL SHALL BE SUPPORTED AT 36" ON CENTER MAX. CONCRETE PLACEMENT SHALL BE DONE IN SUCH A MANNER AS TO INSURE THAT THE ALIGNMENT OF THE REINFORCING STEEL DOES NOT CHANGE. 11. REFER TO DESIGN LETTER WHICH ACCOMPANIES THIS PLAN FOR SOILS INFORMATION UTILIZED IN THE DESIGN OF THIS FOUNDATION. 12. FRAMEWORK ABOVE THE FOUNDATION SHOULD BE DESIGNED TO RESIST DIFFERENTIAL MOVEMENTS ASSOCIATED WITH THE EXISTING PLASTIC SOILS. THIS SHOULD INCLUDE EXPANSION JOINTS IN THE BRICK VENEER. 13. MODIFICATION OF THIS STRUCTURAL DESIGN WITHOUT PRIOR WRITTEN CONSENT OF GRAHAM - MARTIN, INC. WILL VOID ANY RESPONSIBILITY BY GRAHAM - MARTIN, INC. WITH REGARD TO LIABILITY ASSOCIATED WITH THE PERFORMANCE OF THIS ENGINEERED FOUNDATION. w w BILL GRAHAM z `d z o 0 � a d Y U � m U 00 00 0 0< m�a �� zLLJa V) oOLL:' to FL z EE w _ _3 o 0 F- d J d' — 06/23/2E WAM. 1 n...MBG — 055940 p man S2.0 FOUNDATION ANCHORAGE REVISIONS BY REVISED DATE BG C❑NTINUOUS SHEATHING INDICATES WOOD STRUCTURAL PANELS APPLIED ABOVE, AROUND AND UNDER (IF APPLICABLE) ALL OPENINGS OF AREA SHOWN ON PLAN. REFER TO NOTE BELOW FOR ALL REQUIREMENTS EXCEPT WIDTH, WHICH SHALL BE AS INDICATED ON PLAN. I AT ALL RAFTER LOCATIONS TO TOP PLATE WHERE RAFTERS ARE NOT PARALLEL TO CEILING JOISTS AND WHERE CEILING JOISTS DO NOT REST ON TOP PLATE AT RAFTERS, INSTALL ONE SIMPSON H2.5 HURRICANE TIE 2 n n RAFTER/TOP PLATE CONNECTION. II II II STUDS 24' MAX ON CENTER FOR WALL 10' OR LESS. STUDS 16' MAX FOR WALL OVER 10'. MINIMUM 3/8' WOOD STRUCTURAL PANEL (OSH, PLYWOOD, OR OTHER APA RATED SHEATHING). UNLESS DIMENSIONED OTHERWISE, ALL PANELS SHALL BE 4' WIDE AND EXTEND FROM TOP PLATE TO BOTTOM PLATE. ALL PANEL EDGES SHALL BEAR ON FRAMING MEMBERS OR SAME DEPTH BLOCKING, NAIL TO STUDS WITH 8d NAIL E 6' O.C. AT ALL EDGES AND 12' O,C. ALONG ALL INTERMEDIATE FRAMING AND BLOCKING. NAILS SHALL BE PLACED NO LESS THAN 3/8' FROM PANEL EDGE. ICHOR BOLTS TYP. SEE FOUNDATION ANCHORAGE NOTES FOR ADDITIONAL INFORMATION. (STRUCTURAL PANEL DETAIL NOTE: PROVIDE MIN. 2 X 4 BLOCKING @ ANY WOOD STRUCTURAL PANEL JOINT SECOND STORY PANELS SHALL EXTEND FROM TOP PLATE OF FIRST FLOOR (THROUGH JOIST SPACE) TO TOP PLATE OF SECOND FLOOR, SEE NOTES IN DETAIL 1. II II II II J r STUDS 16' MAX ON CENTER. r� 1 IN LIEU OF DETAIL N1 (STRUCTURAL PANEL), CONTINUOUS DIAGONAL V X 4' WOOD (OR APPROVED STRUCTURAL METAL STRAPS) INSTALLED AT 45 TO 60 DEGREES, STUDS SHALL BE SPACED AT 16' MAX. ON CENTER. TWO 8d NAILS REQUIRED AT EACH STUD AND TOP AND BOTTOM PLATE. METAL STRAPS SHALL BE INSTALLED PER O MANUFACTURER SPECS. FLAT METAL (p STRAPS MUST TYPICALLY BE / INSTALLED IN 'X' OR 'V' SHAPED ah PAIRS. 1/2' DIAMETER ANCHOR BOLTS TYP. SEE FOUNDATION ANCHORAGE NOTES FOR ADDITIONAL INFORMATION. I C OPTIONAL LET —IN BRACE DETAIL FULL LENGTH WOOD HEADER, EXTEND OVER JAMBS @ BOTH ENDS NAIL SHEATHING TO HEADER ® 3" O.C. BOTH WAYS TYP. �V� /�I SHEATH BOTH SIDES II/ LSTA24 STRAPS (BACK SIDE IV APA RATED SHEATHING /I SIDE ONLY) AT EACH END. �✓ 24/0 EXP 1, 3/8" /EXTEND STRAP TO TOP PLATE i✓ MINIMUM TYP. / IF FRAMING EXISTS ABOVE / HEADER. / IA. ANCHOR SIMPSON STHD10 BOLTS TYP. STRAPS (2) / ' y � f �. REF. PLAN 1'-4�MIN. 1,- 4„ MIN. C TYPICAL BRACED PANEL DETAIL _1'RAP VIDE ;Vow", Villo -.r CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 06/25/2026 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVED. SHEATH BOTH SIDES APA RATED SHEATHING 24/0 EXP 1, 3/8" MINIMUM TYP. llr—(2) 1/2" DIA. ANCHOR BOLTS SIMPSON STHD10 NAIL PER MANF. REC. C BRACED WALL SECTION �SIMPSON STHD10 STRAP 1� FUTURE TOP OF SLAB �1 \ NAIL STAP TO BRICK LEDGE FORM '-- FOUNDATION BEAM OSTRAPPING INSTALLATION 1) WOOD SOLE PLATES OF ALL EXTERIOR WALLS AND, IF REQUIRED, SOLE PLATES OF BRACED WALL PANELS AT BUILDING INTERIORS SHALL BE ANCHORED TO FOUNDATION WITH 1/2' DIAMETER ANCHOR BOLTS EXTENDING A MIN. OF 7' INTO CONCRETE. ANCHOR BOLTS SHALL BE PLACED WITHIN 12' OF EACH END OF EACH EXTERIOR PLATE SECTION AND AT 6' MAX SPACING BETWEEN ENDS, WITH TWO BOLTS MIN. PER PLATE SECTION. A NUT AND WASHER SHALL BE TIGHTENED ON EACH ANCHOR BOLT. A SIMPSON TITEN HEAVY DUTY SCREW ANCHOR (THD50600H), INSTALLED PER MANUFACTURER'S RECOMMENDATIONS, MAY REPLACE ABOVE ANCHOR BOLTS. 2) CAST -IN -PLACE SIMPSON STRAPS (STD10) SHALL BE REQUIRED AS SHOWN ON PLAN AND DETAILS. IF A STAR IS OMITTED AT POUR, SIMPSON HTT5, INSTALLED WITH 5/8' ALL THREAD BAR (ASTM F1554 GRADE 36 OR A36 MIN) EPDXIED INTO FOUNDATION PER MANUFACTURER'S RECOMMENDATIONS MAY BE USED AS A REPLACEMENT. FRAMING ACCESSORIES, 1) FACE MOUNT HANGERS OR TOP FLANGE HANGERS SHALL BE USED FOR JOISTS AND BEAMS WHERE THEY DO NOT REST ON APPROVED LOAD BEARING SURFACES. 2) RAFTER CLIPS (SIMPSON H2.5 OR EQ.) SHALL BE USED TO ATTACH RAFTERS TO PLATES AT EXTERIOR WALLS WHEREVER RAFTERS ARE NOT PARALLEL TO AND NAILED TO CEILING JOISTS AT TOP PLATES. NON -MASONRY CHIMNEY FRAMING, 1) VERTICAL FRAMING IN CHIMNEY SHALL BE CONTINUOUS LUMBER FROM THE PLATE OF THE CHIMNEY CAP DOWNWARD. IF SPLICING IS NECESSARY, IT SHALL HAVE A MINIMUM LAP OF 48', NAILED WITH TWO 12d NAILS AT 6' ON CENTER. ALL CHIMNEY CORNERS SHALL BE CONSTRUCTED WITH A MINIMUM OF THREE 2X4 VERTICAL MEMBERS. INTERMEDIATE VERTICAL FRAMING, IF NEEDED, SHALL NOT EXCEED 24' ON CENTER. 2) ALL TRIPLE CORNER MEMBERS SHALL EXTEND FROM THE PLATE OF THE CHIMENY CAP DOWNARD TO THE BOTTOM PLATE OF A WALL (OR TO THE HEADER JUST ABOVE THE FIREBOX WHERE THE FIREBOX BLOCKS ACCESS TO THE BOTTOM PLATE) UNLESS MORE THAN 50% OF THE CHIMNEY IS LOCATED BELOW THE ROOF LINE AND INSIDE THE STRUCTURE. WHERE MORE THAN 50% OF THE CHIMNEY IS LOCATED BELOW THE ROOFLINE AND WITHIN THE STRUCTURE, THE TRIPLE CORNER MEMBERS SHALL EXTEND A DISTANCE BELOW THE ROOFLINE EQUAL TO OR GREATER THAN THE PORTION ABOVE THE ROOFLINE. IN THIS CASE, EXEND THE TRIPLE CORNER MEMBERS TO THE TOP PLATE OF A BEARING WALL, A BEAM RESTING ON A BEARING WALL OR A FLOOR JOIST RESTING ON A BEARING WALL. 3) THE TRIPLE CORNER MEMBERS SHALL BE ANCHORED TO THE WALL PLATE AND STUDS OR TO STRUCTURAL MEMBERS SUCH AS JOISTS, GIRDERS OR HEADERS WITH STRUCTURAL STRAPPING SUCH AS SIMPSON H6 OR EQUIVALENT, CORNERS SHALL ALSO BE ANCHORED TO ROOF RAFTERS WHERE THEY PASS THROUGH THE ROOF WITH APPROPRIATE METAL CLIPS. 4) CHIMNEY FRAMING SHALL BE SHEATHED CONTINUOUSLY ABOVE THE ROOF LINE WITH MIN. 3/8' WOOD STRUCTURAL PANEL COSH OR PLYWOOD) OR OTHER APA RATED SHEATHING). VERTICAL JOINTS SHALL OCCUR ONLY AT CORNERS OR ON INTERMEDIATE VERTICAL FRAMING WHERE THE WIDTH OF THE CHIMNEY EXCEEDS THE WIDTH OF SHEATHING. HORIZONTAL JOINTS SHALL OCCUR ONLY ON HORIZONTAL FRAMING MEMBERS OR BLOCKING OF THE SAME DEPTH, THE EDGES OF ALL SHEATHING SHALL BE NAILED WITH 8d NAILS 2 4' ON CENTER, NO LESS THAN 3/8' FROM PANEL EDGE. INTERMEDIATE (IN -FIELD) NAILING SHALL BE 12' ON CENTER. CONT. SHEATHING SEE DETAIL #1 n n LOWER LEVEL WIND -BhACING PLAN WIND —BRACING DESIGN PERFORMED PER THE REQUIREMENTS OF THE 2018, 2021 & 2024 IRC WITH DESIGN WIND SPEEDS OF 115 MPH (3 SECOND GUST) AND 90 MPH FASTEST SUSTAINED SPEED, EXPOSURE B ALL BEAMS SHALL BED A MINIMUM OF 6" INTO UNDISTURBED SOILS OR PROPERLY COMPACTED FILL SOILS BUILDER TO VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO CONSTRUCTION OF THIS SLAB DRAWING SCALE: 3/16" f-o" CONT. SHEATHING SEE DETAIL #1 Qm m c� a m � I m .`9 r z w � F�--4 E aa S<1 z z Z� I � � I p� co F m V)0 m Z5 M CV xaLo N V, 0 A F�+-1 0 � as W z z o � 0 Q (L � � Q (D m U 0 0 o QQmxo zw ^mow 0 (Y O F T w z ♦ ♦ %* %_ • _ J O H- CL J 't CY BILL GRAHAM ...67899 DATE- 04/16/2E .............67899 � ..� SCAU� : 1 SS/ONAL �G JOR 055940 F1.0 FRAMING NOTES: REVISIONS BY REVISED 06/23/2026 BG CLOUDE 1. FRAMING MATERIALS U.N.O.: FB = 1300 PSI FV = 85 PSI E = 116001000 PSI (SOUTHERN YELLOW PINE #2 KD) STUDS SUPPORTING ROOF & CEILING ONLY TO BE 16" O.C. UNLESS NOTED OTHERWISE. STUDS SUPPORTING ROOF, CEILING & FLOOR LOADS TO BE 16" O.C. PROVIDE A SIGNED AND SEALED ENGINEERS LETTER CONFIRMING ONSITE INSPECTION AND APPROVAL OF ALL STRUCTURAL STEEL, WELDS, CONNECTIONS, AND FRAMING. —F=r= �0 m 0 0 ice■ i 0 m ■0 m flown !SET THESE BEAMS DIRECTLY UNDER 2ND STORY WALL ABOVE - -1 n CEILING n F JR, A M I N G n —]B x x Ax x x x it x x- IQN101�[e1y:1:1UTIIf m- L414 1060 A. ALL CEILING JOISTS ARE 2 X 6'S @ 16" O.C. B. (3) — 1 J" X 18" LVL FLUSH BEAM C. W 18 X 35 STEEL BM SET BOT OF BM FLUSH W/ CEILING AND EXTEND TOP OF BM INTO WALL ABOVE. D. (3) — 1 X 9 4" LVL FLUSH BM. I S AP VIDE, r u °i CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 06/25/2026 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVED. I I - I I I � I I PUMN I I � B.B. B.B. _ •� m-V7 PUPUN I I I F- I _ I I I-1 -- — — -- -- — — -- -- I �i��"F R_�_1FT]ER FQAMING PLAN ALL BEAMS SHALL BED A MINIMUM OF 6" INTO UNDISTURBED SOILS OR PROPERLY COMPACTED FILL SOILS BUILDER TO VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO CONSTRUCTION OF THIS SLAB DRAWING SCALE: 3/1 6" = 1'-0" 0 I N ROOF FRAMING NOTES: A. ALL RAFTERS ARE 2 X 6'S ® 24" O.C. FOR COMP SHINGLE ROOF. B. "B.B." INDICATES BEAM BELOW 0 O I 0 P L A m E-I a co o 0-4 t~ x a I I` S0 x vocm P �o a A w Z Z o � 0 Q CD CD } m Y � O o U o Q Q m 0 Q LL z ' ^ CD W 0 af O z cn w wQIL: CD _ _J O f d J d Dar 04/16/2E SCAB: 1 —BG — JOB: 055940 SHr F2.0