Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
25-003453
GENERAL NOTES 1. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. SUBCONTRACTORS SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. 2. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 3. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 4. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 5. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE SUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION SPACE FOR APPROVAL BY THE CONTRACTOR. 6. THE SUBCONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 7. THE SUBCONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. 8. SUBCONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWING MUST BE VERIFIED. SUBCONTRACTOR SHALL NOTIFY THE CONTRACTOR OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 9. ALL SAFETY PRECAUTIONS MUST BE TAKEN WHEN WORKING AROUND HIGH LEVELS OF ELECTROMAGNETIC RADIATION. EQUIPMENT SHOULD BE SHUTDOWN PRIOR TO PERFORMING ANY WORK THAT COULD EXPOSE THE WORKERS TO DANGER. PERSONAL RF EXPOSURE MONITORS ARE ADVISED TO BE WORK TO ALERT OF ANY DANGEROUS EXPOSURE LEVELS. DRIVING DIRECTIONS: FROM 7668 WARREN PKWY, FRISCO, TX 75034, HEAD SOUTH TOWARD MCCANDLESS WAY, GET ON SAM RAYBURN TOLLWAY FROM PARKWOOD BLVD AND STATE HWY 121 S (5 MIN, 1.7 MI), CONTINUE ON SAM RAYBURN TOLLWAY TO GRAPEVINE. TAKE THE EXIT TOWARD BASS PRO DR FROM STATE HWY 121 S (15 MIN, 16.6 MI), CONTINUE ON TX-26 S. DRIVE TO GAYLORD TRAIL (7 MIN, 2.6 MI). DESTINATION.WILL BE ON THE RIGHT. • APPROVED FOR CONSTRUCTION T m O 1 Pw PROPERTY OWNER OR REP. RF RIP TO REPLACE VANGUARD LAND USE PLANNER NETWORK SITE NAME GAYLORD TEXAN SITE NUMBER DA01962A SITE ADDRESS 1501 GAYLORD TRAIL GRAPEVINE, TX 76051 TARRANT COUNTY BUILDING CODES - INTERNATIONAL BUILDING CODE, 2021 AS ADOPTED BY LOCAL JURISDICTION. 2020 - NATIONAL ELECTRICAL CODE, 2828 AS ADOPTED BY LOCAL JURISDICTION. - INTERNATIONAL MECHANICAL CODE, 2021 AS ADOPTED BY LOCAL JURISDICTION - INTERNATIONAL PLUMBING CODE, 2021 AS ADOPTED BY LOCAL JURISDICTION. VICINITY MAP ALL CHANGES REQUIRE ENLARGED VICINITY MAP APPROVAL OF REVISED PLANS ;.k ` O Relax 8 Renew Wrt4 Massage Oak Grove APPROVED PLANS SHALL BE Pa•k KEPT ON JOBSITE AT ALL TIMES _ 21 Hilton DFW 0 rBtao Lakes ExecutiveQooSITE _ wLn Ne SEPERATE PLUMBING, MECHANICAL, ELECTRICAL AND *4-_odLn he Church of Christ tofLatter-de SIGN PERMITS SHALL BE REQUIRED. lug I k Ln N z © Grapevine RECEIVED: 9/10/2025 25-003453 "T Mobile" 1501 Gaylord TH Cell Tower Modifications N SITE = P a� 3 G� Dr Van Td Moode o Home Park v private Dr Rish My Passport Q CONSTRUCTION HOURS 7:00 A.M. - 7:00 P.M. Bushong Rd MONDAY - SATURDAY ONLY NO WORK PERMITTED ON SUNDAY NRiverside Or Q• J c _Y .r N •u e,KoOd L 1 -44 D o s� ?r 4 �- Build -A -Bear Workshop k1/ • �antrra © t q + o � o r q 0 � i Sans D:�:K Boat Rentals S Party Barges O,rapevine Elks ? . odge = 2483 O Five Star Laundry - Dallas Bushong Rd p Dolla• Ca Rental Gaylord Texan Dol_a, a, C Po �4 t S:Ive' LaKe Manna T-MOBILE OPERATIONS SHEET INDEX T-1 TITLE SHEET C-1 OVERALL SITE PLAN C-2 ENLARGED SITE PLAN C-3 EQUIPMENT DETAILS G-1 GROUNDING DETAILS S.o.W BACKHAUL CONSTRUCTION CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 09/24/2025 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVED. - INSTALL (1) 2" FIBER CONDUIT FROM FDP ON THE RACK IN DATA CENTER FOR FRONTIER BACK TO FRONTIER RAC 24 ON EXISTING H-FRAME IN ROOM C-3149 IDF BR-5 ON 3RD LEVEL (DA01962A) - INSTALL (1) NEW FRONTIER RAC24 FIBER BOX ON WALL. - INSTALL (1) 2" -48V DC POWER CONDUIT FROM FRONTIER AAV BOX TO TMO RACK - INSTALL (1) 2" FIBER CONDUIT FROM FRONTIER MV BOX TO TMO RACK PROJECT SUMMARY SITE TYPE EXISTING BILDING SITE INFORMATION LAT: 32' 57' 19.24"' N LONG: -97' 03' 53.85 W JURISDICTION: CITY OF GRAPEVINE OCCUPANCY: UNMANNED ZONING: N/A CONSTRUCTION TYPE: EXISTING BILDING APPLICANT T-MOBILE DALLAS DUKE BRIDGES CAMPUS, 7668 WARREN PARKWAY FRISCO, TX 75034 OFFICE (972) 464-3510 PROJECT MANAGER: ROBERT GAMIS EMAIL: Robert.Gamis241T-Mobile.com LANDLORD OPRYLAND HOTEL 1 GAYLORD DR NASHVILTE, TN 37214-1207 ` o 0 16a CONTRACTOR SHALL CALL FOR INSPECTIONS: `c`oo Beverly Dr 0 t c� d� (817) 410-3010 CONTRACTOR REGISTRATION WILL BE s e' REVOKED UPON PERMIT EXPIRATION. CONTRACTORS: A&E CONTRACTOR ALLPRO CONSULTING GROUP, INC. 9221 LYNDON B. JOHNSON FREEWAY, SUITE 204 DALLAS, TX 75243 CONTACT: SHIQIANG ZHANG P.E. OFFICE: 972-231-8893 FAX: 866-364-8375 EMAIL: PMOALLPROCGI.COM TEXAS ONE CALL CONTRACTOR TO CALL 48 HOURS BEFORE DIGGING! PHONE: 800-545-6005 INDEPENDENT LOCATORS TO BE USED ON ALL SITES `Know what's below. Call before you dig. CHECKED BY SZ 0 08/15/25 FINAL CD ALLPRO CONSULTING GROUP, INC. 9221 Lyndon B Johnson Fry Surte 204, Dolin Tx 75243 Phone: 972-231-8893 F= 866-364-8375 r .dlprocgi.corn Frm No. F-8242 08/26/25 .... '.. ....................... SHIQUNG ZMANG o, 137482 1.ki kLM CONSULTING GRIXIP, INC FIRM NO. F-8242 DA01962A GAYLORD TEXAN 1501 GAYLORD TRAIL GRAPEVINE, TX 76051 TARRANT COUNTY SHEET TITLE TITLE SHEET SHEET NUMBER T-1 NOTE: SITE LAYOUT IS BASED GOOGLE MAP AND SITE WALK BY ALLPRO CONSULTING GROUP. INC.ACGIp25-6247 DATED 08/22/25, ANY DISCREPANCY IS NOTICED BETWEEN THE ACTUAL SITE LAYOUT AND THESE DRAWINGS, PLEASE NOTIFY ALLPRO CONSULTING GROUP, INC. FOR A REDESIGN. w NOTE: ALL INSTALLATIONS SHOULD BE IN COMPLIANCE WITH ANSI/ASSE A10.48 AND ANY OTHER SAFETY STANDARDS NOTE: �+ THE EXISITING SITE LIES IN FLOOD ZONE X, AREA OF MINIMAL FLOOD HAZARD, PER FIRM MAP d48439CO105K EFFECTIVE i 09/25/2009.IF A PROFESSIONAL CONSULTANT HAS FINDINGS OF FLOODING/WETLANDS CONTACT ALLPRO CONSULTING GROUP, INC. FOR A REDESIGN. NOTE: GC MUST PERFORM UTILITY LOCATE PRIOR TO ANY GROUND WORK, ALL NEW UNDERGROUND CONDUITS TO BE CONTAINED WITHIN EXISTING UTILITY EASEMENT. NOTE: FIBERLIGHT AAV EOUIPMENT TO BE REMOVED BY GC AT LATER DATE ONCE FRONTIER EOUIPMENT ARE INSTALLED. & A NOTES: OUR SITE PLAN WAS PREPARED WITH THE BENEFIT OF RECENT SURVEY BY NATIONAL SURVEYING SPECIALIST, DATE:03/10/05 NO PROPERTY LINES OR EXISTING EASEMENT INFORMATION WAS MADE AVAILABLE TO ALLPRO CONSULTING GROUP, INC., AT THE TIME OF PREPARATION OF THESE PLANS. DUE DILIGENCE SHALL BE DONE BY OTHERS BEFORE THE SITE IS BUILT AS SHOWN. IN CASE OF ANY CONFLICTS DUE TO PROPERTY LINES OR NEW EXPANSION ON EXISTING EASEMENTS OR DUE TO LANDLORD PREFERENCE FOR A DIFFERENT DESIGN, PLEASE CONTACT ALLPRO CONSULTING CROUP, INC., FOR A REDESIGN. LEGEND EXISTING BUILDING/EQUIPMENT — P — POWER LINE F =FIBER LIN NEW EOUI WENT x — FENCE .GRAPEVENE CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 09/24/2025 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVED. NORTH OVERALL SITE PLAN — FINAL NO SCALE 1 s ,*N (14 (E) DATA CENTER / WITH FRONTIER e FIBER DEMARC / r F NEW 2" FIBER CONDUIT FOR FRONTIER FROM EXISTING DATA CENTER ON 2ND FLOOR TO ROOM C-3149 IDF BR-5 ON 3rd LEVEL 11 Z • • F \F ` • F \ f \ f \ f W1 �' (E) T-MOBILE HEAD END ROOM LOCATED ON 3RD FLOOR C-3149 OF BR-5 F - j 1 Q a Q � a z w o to tX vi H- Z) O T1 U Tn V LL m w C7 co m w Y 0 ACGI NO: 25-6239 DRAWN BY: WZ CHECKED BY: SZ 0 08/15/25 FINAL CO 1 • ALLPRO CONSULTING GROUP, INC. 9221 Lyndon B Johnson F.y Sidle 204, Dolin Tx 75243 Phone: 972-231-8893 Fo.: 866-364-8375 "..dtprocgi.cam Firm No. F-8242 08/26/25 0f rfx4s SHIOUNG. 2MANG 137482 AUPRO CONAILTING GROUP, W. FRY NO. F-8242 DA01962A GAYLORD TEXAN 1501 GAYLORD TRAIL GRAPEVINE, TX 76051 TARRANT COUNTY SHEET TITLE OVERALL SITE PLAN SHEET NUMBER C-1 NOTE: SITE LAYOUT IS BASED ON PREVIOUS CAD DWG's BY ATC (ATC TOWER SERVICES, LLC) ,DATED 09/17/2020. ANY DISCREPANCY IS NOTICED BETWEEN THE ACTUAL SITE LAYOUT AND THESE DRAWINGS, PLEASE NOTIFY ALLPRO CONSULTING GROUP, INC. FOR A REDESIGN NOTE: ALL INSTALLATIONS SHOULD BE IN COMPLIANCE WITH ANSI/ASSE A10.48 AND ANY OTHER SAFETY STANDARDS NOTE: THE EXISITING SITE LIES IN FLOOD ZONE X. AREA OF MINIMAL FLOOD HAZARD, PER FIRM MAP #48085C039OK EFFECTIVE 06/07/2017 IF A PROFESSIONAL CONSULTANT HAS FINDINGS OF FLOODING/WETLANDS CONTACT ALLPRO CONSULTING GROUP, INC. FOR A REDESIGN. NOTE: GC MUST PERFORM UTILITY LOCATE PRIOR TO ANY GROUND WORK. ALL NEW UNDERGROUND CONDUITS TO BE CONTAINED WITHIN EXISTING UTILITY EASEMENT. NOTE: FIBERLIGHT AAV EQUIPMENT TO BE REMOVED BY GC AT LATER DATE ONCE FRONTIER EQUIPMENT ARE INSTALLED. NOTES: OUR SITE PLAN WAS PREPARED PATH THE BENEFIT OF RECENT SURVEY BY NATIONAL SURVEYING SPECIALIST, DATE:03/10/05. NO PROPERTY LINES OR EXISTING EASEMENT INFORMATION WAS MADE AVAILABLE TO ALLPRO CONSULTING GROUP, INC., AT THE TIME OF PREPARATION OF THESE PLANS. DUE DILIGENCE SHALL BE DONE BY OTHERS BEFORE THE SITE IS BUILT AS SHOWN. IN CASE OF ANY CONFLICTS DUE TO PROPERTY LINES OR NEW EXPANSION ON EXISTING EASEMENTS OR DUE TO LANDLORD PREFERENCE FOR A DIFFERENT DESIGN, PLEASE CONTACT ALLPRO CONSULTING GROUP, INC.. FOR A REDESIGN. GR P. E�l NE CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 09/24/2025 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVED. LEGEND EXISTING BUILDING/EQUIPMENT — P — POWER L114E F FIBER LIN - NEW EQUI MENT — x — FENCE NORTH SITE PLAN — HEAD END ROOM NO SCALE 2'-4" EXISTING RACK 2'-6" Q a. Q � a z w o r¢¢` to TX c6 H- � O d U m V LL m w C7 10'-7" � co m w ]C 1'-3" 1'-9' 2'-6" 6" — Z) 0 ACGI NO: 25-6239 DRAWN BY: WZ 1 CHECKED BY: SZ 0 08/15/25 FINAL CO T-MOBILE RACK N NEW (1) 2" -48V DC POWER CONDUIT FROM NEW FRONTIER RAC24 BOX TO EXISTING RACK W'-7") EXISTING ALLPRO RACK ^ NEW (1) 2" FIBER CONDUIT FROM NEW FRONTIER RAC24 BOX TO CONSULTING GROUP, INC. i EXISTING RACK (!2'-7") 9221 Lyndon B Johnson F.y Suite 204, Dolts, Tx 75243 Phone: 972-231-8893 Fo.: 866-364-8375 rww.dIpcocgi.cam i-im No.f-8212 NEW FRONTIER AAV BOX RAC24 1 OB/26/25 Y-O" (E) CABLE S..... 2MANG„ PENETRATIONS o ; 137482 2c� O O O O j lO...... A.LPRO CONSUL➢NC CROUP, WI FIRM NO. F-8242 DA01962A GAYLORD TEXAN 1501 GAYLORD TRAIL GRAPEVINE, TX 76051 TARRANT COUNTY SHEET TITLE SITE PLAN -HEAD END ROOM SHEET NUMBER C-2 �. I1i6_*-_11 RAC24 24"Outdoor Equipment Cabinet Overview The Remote Access Cabinet (RACr") product family from Purcell Systems is as diverse and versatile as enclosures get. From 18" to more than 68", the RAC series of enclosures have a size and configuration ideal for every outside equipment deployment requirement you have. The latest addition to Purcell's ever-growing product portfolio, the RAC24 provides 5RU of 19" rack space, multiple environmental options with field -adjustable thermostat, optional AC receptacle, knockouts for cable entry, and pole, h-frame and wall -mounting capability. PRODUCT SPECIFICATION 1 RAC24 (lop),I.jith TEC option help. and door open (above) RAC TM RAC24 TECHNICAL SPECIFICATIONS Physical Dimensions Extenor: 24'H x 15"W x 18.5"D (width does not incl. fan shroud) Interior: 23'H x 14"W x 17.5"D Weight: 35 Ibs; 50 Ibs w/ fan option; 67 Ibs w/ TEC 85 Ibs w/ 2k BTU/hr air conditioner Construction Materials Material: Aluminum (lightweight, corrosion -resistant) Paint: UL Pantone, ultra -light grey, TGIC polyester powder coat Door/Side Panel Construction Doors: Front door with door alarm Rear Panel: Removable back panel for rear equipment access Latches: Dual -point latched and pad lockable (padlock provided by end -user) Gasket: ASTM and UL listed for outdoor use Equipment Mounting Equipment Rack: 5RU of 19" equipment space (vertically -mounted) Environmental Options Fan System: +24VDC,-48VDC, or 120VAC Single fan system with field -adjustable thermostat. Includes GORE filter for environmental protection Thermoelectric System Purcell FA200TEC: 20OW side -mounted TEC, field -adjustable, +24VDC or -48VDC Air Conditioner: 2,000 BTU/hr side -mounted air conditioner Standard Components Integrated Grounding: UL-listed bonding hardware and easily accessible mounting points for "single -point" ground Optional Configurations AC Outlet Receptacle: Two -outlet 15A std. AC receptacle Distribution: Optional internal AC or DC distribution Alarming: 6 position alarm block available Mounting: Pole -mount kit available Agency Information UL 508A NEMA Type 3R (pending), NEC Warranty Information Limited warranty available. Contact your Sales Associate for details. ACGI NO: 25-6239 DRAWN BY: WZ CHECKED BY: SZ 0 08/15/25 FINAL CD ALLPRO CONSULTING GROUP, INC. 9221 Lyndon 8 Johnson Fry Suite 204, Ddios. Tx 75243 Phone: 972-231-8893 Fo.: W-364-8375 NNW. 0IIpoc9i. CM Fv. No. F-8242 08/26/25 rE0F T~' SHIQIANG ZHANG A.....' 37482 ....:� M FS %ONALE� �� ALLPRO CONSULTING CROUP, INC. FIRM NO F-8142 DA01962A GAYLORD TEXAN 1501 GAYLORD TRAIL GRAPEVINE, TX 76051 TARRANT COUNTY SHEET TITLE EQUIPMENT DETAILS SHEET NUMBER C-3 GENERAL NOTES I. ALL ELECTRICAL WORK SHALL CONFORM TO THE NATIONAL ELECTRICAL CODE (EDITION ACCEPTED BY LOCAL JURISDICTION) AND APPLICABLE LOCAL CODES. 2. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE- 3, ALL ELECTRICAL ITEMS SHALL BE U.L. APPROVED OR LISTED. 4. WIRES AND CABLES FOR POWER AND LIGHTING SHALL BE COPPER WITH TYPE XHHW, THWN. OR THHN INSULATION. SOLID CONDUCTORS FOR /10 AWG AND SMALLER, STRANDED FOR LARGER THAN /10 AWG. MINIMUM SIZE p2 AWG. 5. WIRES AND CABLES FOR POWER SHALL BE INSTALLED IN GALVANIZED RIGID STEEL CONDUIT OR FLEXIBLE LIQUID TIGHT CONDUIT AS INDICATED ON DRAWING. 6. CONTRACTOR TO OBTAIN ALL PERMITS. PAY PERMIT FEES. AND BE RESPONSIBLE FOR SCHEDULING INSPECTIONS. 7. CONTRACTOR TO OBTAIN LOCAL POWER AND TELEPHONE COMPANY APPROVAL AND COORDINATE WITH UTILITY COMPANIES SERVICE ENTRANCE REOUIREMENTS. 8. PROVIDE ALL LABOR AND MATERIAL DESCRIBED ON THIS DRAWING. AND ALL ITEMS INCIDENTAL TO COMPLETING AND PRESENTING THIS PROJECT AS FULLY OPERATIONAL. 9. GROUNDING CONNECTIONS SHALL BE EXOTHERMIC TYPE ("CADWELD•) TO ANTENNA MASTS, AND THE GROUND BARS. REMAINING GROUNDING CONNECTIONS SHALL BE COMPRESSION FITTINGS. 10. GROUND COAXIAL CABLE SHIELDS AT BOTH ENDS WITH COAX CABLE GROUNDING KITS & INSTALL WEATHER PROOFING KIT AT EACH CONNECTION 1T. ROUTE GROUNDING CONDUCTORS ALONG THE SHORTEST AND STRAIGHTEST PATH POSSIBLE, EXCEPT AS OTHERWISE INDICATED. GROUNDING LEADS SHOULD NEVER BE BENT AT RIGHT ANGLE, ALWAYS MAKE AT LEAST 12- RADIUS BENDS. /6 WIRE CAN BE BENT AT 6- RADIUS WHEN NECESSARY 12. CONTRACTOR TO PROVIDE GROUND RING AS SHOWN ON GROUNDING SITE PLAN AND GROUNDING RISER DIAGRAM CONTRACTOR SHALL TEST AND VERIFY THAT THE IMPEDANCE DOES NOT EXCEED 5 OHMS TO GROUND BY MEANS OF A BIDDLE-MEGGER TESTER. GROUNDING AND OTHER OPERATIONAL TESTING SHALL SHALL BE WITNESSED BY THE OWNER'S REPRESENTATIVE. 13. CONTRACTOR TO PROVIDE TELEPHONE CONDUIT AS SHOWN ON PLANS 14. CONTRACTOR TO PROVIDE ELECTRIC CONDUIT AS SHOWN ON PLANS 15 NOTIFY LOCAL UTILITY SERVICE PRIOR TO ANY INSTALLATION 16, ALL EQUIPMENT FURNISHED BY OTHERS SHALL BE PROVIDED WITH PROPER MOTOR STARTERS, DISCONNECTS, CONTROLS, ETC. BY THE ELECTRICAL CONTRACTOR UNLESS SPECIFICALLY NOTED OTHERWISE. THE ELECTRICAL CONTRACTOR SHALL INSTALL AND COMPLETELY WIRE ALL ASSOCIATED EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S WIRE DIAGRAMS AND AS REQUIRED FOR A COMPLETE OPERATING INSTALLATION. ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF EQUIPMENT PRIOR TO ROUGH -IN OF CONDUIT AND WRING TO AVOID CONFLICTS. WHERE APPLICABLE 17. GROUNDING CONDUCTORS SHALL BE COPPER ONLY. ABOVE GROUND EITHER SOLID OR STRANDED CONDUCTORS ARE PERMITTED. IGR AND ALL EXTERNAL CONDUCTORS (WITH THE EXCEPTION FOR GROUND WARE BETWEEN THE TOP AND THE BOTTOM OF THE ANTENNA TOWER) MUST BE BARE. EQUIPMENT GROUND LEADS IN CABLE TRAYS MUST BE GREEN INSULATED 18, UTILITY COMPANY COORDINATION: ELECTRICAL CONTRACTOR SHALL CONFIRM THAT ALL WORK IS IN ACCORDANCE WITH THE RULES OF THE LOCAL UTILITY COMPANY BEFORE SUBMITTING HIS BID, THE CONTRACTOR SMALL CHECK WITH THE UTUTY COMPANIES SUPPLYING SERVICE TO THIS PROJECT AND SHALL DETERMINE FROM THEM ALL EQUIPMENT AND CHARGES WHICH THEY WILL REQUIRE AND SHALL INCLUDE THE COST IN HIS BID 19. ALL CADWELDS ABOVE FINISHED GRADE SHALL BE PAINTED WITH CO -GALVANIZED ZINC ENRICHED PAINT TO MATCH COLOR OBJECT BONDED TO. za t4 TYPE PT TYPE GR TYPE VB (TOWER GROUNDING TAB) HEAT SHUN CN GATES ONLY TYPE VS TYPE GL LUG TYPE VBC TYPE TA TYPE HS TYPE SS TYPE GT TYPE HA TYPE XA NOTE: CADWELD "TYPES- SHOWN ABOVE ARE EXAMPLES CONSULT WITH PROJECT MANAGER FOR SPECIFIC TYPES OF CADWELDS TO BE USED FOR THIS PROJECT. CADWELD TYPES 0,2SCALE: N.T.S CONDUITS AND WIRING 1. WIRING OF EVERY KIND MUST BE INSTALLED IN CONDUIT, UNLESS NOTED OTHERWISE. OR AS APPROVED BY THE ENGINEER 2.UNLESS OTHERWISE SPECIFIED, ALL WIRING SHALL BE COPPER (CU) TYPE THWN. SIZED IN ACCORDANCE \WTH THE NATIONAL ELECTRICAL CODE 3.RACEWAYS SHALL BE GALVANIZED STEEL, SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE. UNLESS OTHERWISE NOTED. ALL RACEWAYS SHALL BE APPROVED FOR THE INSTALLATION 4,PULL OR JUNCTION BOXES SHALL BE PROVIDED AS REQUIRED TO FACILITATE INSTALLATION OF RACEWAYS AND WIRING 5.PROVIDE A COMPLETE RACEWAY AND WIRING INSTALLATION, PERMANENTLY AND EFFECTIVELY GROUNDED IN ACCORDANCE WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE AND LOCAL CODES COORDINATION WITH UTILITY COMPANY THE ELECTRICAL CONTRACTOR SHALL COORDINATE COMPLETE ELECTRICAL SERVICE WITH LOCAL UTILITY COMPANY FOR COMPLETE OPERATIONS SYSTEM, INCLUDING TRANSFORMER CONNECTIONS. CONCRETE TRANSFORMER PADS, IF REWIRED, METER SOCKETS, PRIMARY CABLE RACEWAY REQUIREMENTS, SECONDARY SERVICE. ETC. PRIOR TO SUBMITTING BID TO INCLUDE ALL LABOR AND MATERIALS. LEGEND SIZED ASNOTTEED CT SWITCH, O PANELBOARD KILOWATT HOUR METER T❑ TRANSFORMER iL CIRCUIT BREAKER 2 LIGHTING FIXTURE. SIZE AS NOTED 0... o 1 COPPER GROUND BAR. SIZED AS NOTED —E — POWER WIRING, SIZED AS NOTED — T — TELCO WIRING. SIZED AS NOTED —G — GROUND WIRING, SIZED AS NOTED FNiSHED GRADE PLUG r COVER TOP OF GRAVEL � �, 1 , rn ®G CHEMICAL FILING CHEMICAL GROUNDING SYSTEM BY: Chem -Rod SUPPLIER: LEC Inc. 6687 ARAPAHOE ROAD BOULDER, CO 80303 (303) 447-2828 A AMPERE V VOLT W WIRE C CONDUIT G GROUND P POLE SPGB SURGE PROTECTOR GROUND BAR (1/4'.2 .24') CGB COLLECTOR GROUND BAR (I/4'x4'x12-) EGS EXTERNAL GROUND BAR (1/4"W44') MGB MASTER GROUND BAR (1/4-.8".24') IGR INTERNAL GROUND RING (-HALO- GROUND) EGR EXTERNAL GROUND RING ACU AIR CONDITIONER UNIT MWGC HEAVY WALLED GALVANIZED CONDUIT EXOTHERMIC MELD CONNECTION C 0 C`1 �lllllE�Jllllf TYP. CHEMICAL GROUNDING DETAIL 022 SCALE: GROUND RING STEEL PIPE 0 DUPE CAP %EP MOLE STAINLESS STEEL HARDWARE LOCKWASHER (TYPICAL) FLAT WASHER (TYPICAL) /-1/2•x1 1/2" HEX BOLT TWO MOLE COPPER NUT (TYPICAL) GROUNDING CABLE COMPRESSION TERMINAL ELEVATION ` GROUND BAR GROUND BAR GROUNDING CABLE EXPOSED BARE COPPER TO BE A KEPT TO ABSOLUTE MINIMUM, NO SECTION 'A -A' INSULATION ALLOWED WITHIN THE COMPRESSION TERMINAL (TYPICAL) NOTE: I. -DOUBLING UP- OR -STACKING ' OF CONNECTION IS NOT PERMITTED 2. OXIDE INHIBITING COMPOUND TO BE USED AT ALL LOCATIONS. TYPICAL GROUND BAR CONNECTIONS DETAIL r3 SCALE: N.T.S. C-2 Q \M M CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 09/24/2025 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVED GRADE CADWELD -30" MIN. RING GROUND /2 AWG BCW GROUND ROD COPPERWELD 5/8'?x8'-0- LONG GROUND ROD SCALE: N.T.S. (503) (;-2 O TO ANTENNA COAX CABLE WEATHER PROOFING KIT ANDREW 0221213 (TYP) FROM ANTENNAk STANDARD ANDREW GROUND KIT vl X JUMPER ( TYP. ) ANTENNA CABLE TO CABLE TRAY ANDREW (TYPO CONNECTOR WEATHERPROOFING /6 AWG FROM ANTENNA /2 AWG BCW BONDED FRAME SUPPORT TO GROUND WIRE ALONG CABLE TRAY 22 AWG BCW GROUNDING BAR, NEWTON, SIMILAR TO WITHOUT INSULATORS. MOUNTED NEAR ANTENNA GROUND WIRE CONNECTION TO GROUND BAR AT ANTENNA SCALE: N.T.S. (514) (G- FOAM SEAL 3/4- SCHED. 40 P.V.C. TYPICAL FROM EQUIPMENT. POLE. OR PLATFORM TYPICAL GROUND 02 BCW WIRE FOAM SEAL PIPE END j GRADE GRAVEL TO GROUND `J if RING GROUND WIRE PIPE SLEEVE 072 SCALE: N.T.S. (572) 4z�� COAX CABLE GROUNDING TYPE YGIBS CLAMP KIT 06 AWG. STRANDED COPPER GROUNDING CONDUCTOR T GROUND TO PRIMARY CABINET COAX CABLE GROUNDING DETAIL SCALE- N.T.S. (513) 00 0 TYPE GAR-TC ® e TYPE YA3CL-2TC38 TYPE BDIBG92 TYPE KC TO PIPE TYPE KC TO FLAT SURFACE OBURNDY DETAILS G-2 SCALE: NONE G-2 a a. Q � a Z W < o f¢¢` 2 "1 LX C7 I— CLO CL U V LL N W C7 CD m W Y 0 ACGI NO: 25-6239 DRAWN BY: WZ CHECKED BY: SZ 0 08/15/25 FINAL CO ALLPRO CONSULTING GROUP, INC. 9221 Lyndon B Johnson Fwy Sidle 204, Dolin Tx 75243 Phone: 972-231-8893 Fo.: 866-364-8375 www.dipnxgi.cam Firm No. F-8242 08/26/25 % .......................... • SHIQUNG.2HANG • o , 137482 4y�3 ALLPRO CONAIITING GROUP, W. IN NO. F-8242 DA01962A GAYLORD TEXAN 1501 GAYLORD TRAIL GRAPEVINE, TX 76051 TARRANT COUNTY SHEET TITLE GROUNDING DETAILS SHEET NUMBER G-1