Loading...
HomeMy WebLinkAboutSFRA2026-001641I 'G� June 17, 2026 Ware Brothers, LLC A i i N: Phil Ware 1001 West Northwest Highway Grapevine, TX 76051 Re: GRAPEVINE FILE #CU26-16; SECONDARY STRUCTURE EXPANSION To Whom It May Concern, This letter is to verify that your request for a conditional use permit located at 101 Cross Creek Drive and platted as Block 2, Lot 3R1 13, Manor Oaks Addition, to exceed the maximum building height for secondary structures on lots 20,000 square foot or greater in size in the "R-20", Single - Family Residential District, specifically for an expansion to an existing secondary structure totaling 19-feet, 10-inches tall, in conjunction with an existing single family detached dwelling, was approved by City Council on June 16, 2026. A copy of the approved exhibits will be provided physically and electronically following execution by City officials. Any changes to a site plan, landscape plan, building elevations, or any other sheets approved with a conditional use or special use (no matter how minor or major) can only be approved by the city council through the public hearing process. No Conditional Use Permit shall be valid for a period longer than one (1) year from the date on which the City Council grants the Conditional Use unless within such one (1) year period: (1) a Building Permit is obtained and the erection or alteration of a structure is started, or (2) an Occupancy Permit is obtained and a use commenced. The City Council may grant one additional extension not exceeding one (1) year, upon written application, without notice or hearing. No additional extension shall be granted without complying with the notice and hearing requirements for an initial application for a Conditional Use Permit. Your next milestone in the development review process is to obtain Building Permit approval with the Building Services Department. For questions related to this process, please reach out to the following individual to coordinate: • Building Permits — Arnoldo Ramirez at (817) 410-3160 or arnoldor@grapevinetexas.gov Planning Services The City of Grapevine * P.O. Box 95104 * Grapevine, Texas ePlanninq 76099 * (817) 410-3155 9 building Permit applications are accepted at any point in the development review process but will not be released until any associated zoning cases or site plans are approved, civil engineenng plans are approved, and any required plats are approved and filed. Please do not hesitate to contact us if we may be of further assistance (817) 410-31559 Sincerely, Erica Marohnic, AICP Planning Services Director W. Ware Brothers Construction, LLC clo Richard and Wmber Ware 101 Cross Creek Drive Grapevine, TX 76051 I .a Planning Services The City of Grapevine * P.O. Box 95104 * Grapevine, Texas 76099 * (817) 410-3155 * htt s:l bit.f IGevineP anning M EXSITING STAIRS 1 OPEN RAIL EXISTING ............ EXISTING GARAGE ............ GYM VV CEILING �UN VAULTED CEILING 0 WATER HEATER O ® 20' AFF. IIEX I5T INC:;` -FLOOR PLAN I a/- I'1'-6' EXISTING GARAGE el' CEILING 9 r 0 '1NEUJ1'—f=LOOfR FLAN 1/4" =1'0" WALL LEGEND NEW WALL EXISTING WALL TO REMAIN 1 a i i rt f f EXSITIW-z 28' HIGH PONY WALL EXSITING 28' HIGH PONY WALL i rt ..............................m LU F n'-4' NEL ATTIC, *1-W n'-4' EXSITING 28' HIGH PONY WALL EXISTING ATTIC EXSITING 28' HIGH PONY WALL "EXIST ING " - SE CONE:) FLOOR FLAN 1/4" = P0" W-V j 4 r- r ar— i 1 I 1 1 I lI I I v 1 i I 1 i I 1 I i W-V 11 IEI I III I � _&ECOD ELECTfRICA I� w III IEUJII-5ECONE:) FLOOR FLAN 1/4" =1'0" NOTES: -CONTRACTOR TO VERIFY ALL DIMENSIONS ON SITE -CONTRACTOR TO COORDINATE REMOVAL OF ANY INTERIOR OR EXTERIOR LOAD BEARING WALLS WITH STRUCTURAL ENGINEER PRIOR TO ANY ON SITE DEMO. DOOR 5C�4EDULE MARKQTY. SIZE DESCRIPTION 1 1 2'5"x6'5" EXT.S.C. WINDOW 5C�4EDULE M,4RKQTY. SIZE DESCRIPTION A 1 2 ITWIN 3'0"x5'0" I S.H.D.L. L FL AN 1/4" =1'0" ELECTRICAL SYM50LS 110V DUPLEX OUTLET RECESSED CEILING MOUNTED LIGHT NOTE: THE GENERAL CONTRACTOR AND ALL SU5CONTRACTORS SHALL REVIEW THE FULL CONTENT OF THE PLANS FOR DISCREPANCIES AND OMISSIONS PRIOR TO COMMENCEMENT OF WOR< Fr=---� ___- =----- =---==___�� I� �I II II =�Ll LL =_— I I II s >r II II II II II II II II II XSTING ROOF g 10:12 I I I II II I I it l j NEW SHIT GL.Z-S 4:12 PITCH II II II II II r II II II II II I i II !I II II I I � >► ! i II i� LL =_— =�=____-- _____--- --LI Y III IEUJII — fP,,.00F FLAN i 14, Lim All documents here attached are Copyrighted 2025 by Exurb Studio, Designer. The Design SpeGifiCations, Drawings and al other documents prepared by the Designer, and (or) the Designer's office are Instruments of service. The Designer shall be dommed the author of these documents and retains all statutory, common law, and other reserved rights including Copyright. The Designer's Design, Drawings, SpeelFieations and all other documents prepared by the Designer and (or) the Designer's office shell not be reused by the Owner (client) or others on any other projoc-t, Including additions or modifications to this project or for completion of this project by others, without permission In writing From the Designer. No part of the above mentioned documents may be reproduced without similar permission from the Designer. The Designer assumes no Iiabillty for any structure built from these plans. Before construction, the purdreser, builder, or contractor must verify all dimensions, verify compliance with all building codes, and Incorporate site conditions. EXURB STUDIO, LLC 1038 MEADOW BEND LOOP N. GRAPEVINE, TX 16051 PHONE: 214-619-35W EMAIL: INFOeEXURBSTUD I OZOM 0 U 0 LnIn m W 3 3 w Q Y UA X LU I � U 0 EE,VISIONO 1. 2. 3. 4. DATE: 2/16/26 PRAM EXS CHECK SY- EXS PROJECT NO. WARE GARAGE Cill° PLATE SHINGLES 6 4:12 TO MATCH EXISTING NL� F RCN T ELEVATICN 1/4" =1'0" SIDING TO MATCH EXISTING 2 10 9'1" PLATE F.F. 12 4 i 12 4I \1 12 � 4 .. 12 I4 N UJ LEFT ELEVATION 1/4" =1'0" F.F. 1 NEUJ iC:Tk�T ELEVATION 1/4" =1'0" SIDING TO MATCH EXISTING 9'1" PLATE NOTE: TI 4E GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL REVIEW THE FULL CONTENT OF THE PLANS FOR DISGREPANGIES AND OMISSIONS PRIOR TO C;01 iMENGEMENT OF UJOR< i USE All documents here attached are Copyrighted 2025 by Exurb Studio, Designer. The Deelgn, 5pecIficattons, Drawings and all other documents prepared by the Designer, and (or) the Designer's office are Instruments of service. The Designer shell be deemed the author of these documents and retains all statutory, common law, and other reserved rights Including Copyright. The Designer's Design, Drawings, Specifications and all other documents prepared by the Designer and (or) the Designer's office shall not be reused by the Owner (client) or others on any other project, Including additions or modifications to this project or for completion of this project by others, without permission In writing from the Designer. No part of the above mentioned documents may be reproduced without similar permission from the Designer. The Designer assumes no Ilability for any structure built from these plane. Before construction, the purchaser, builder, or contractor must verlfy all dimensions, verlfy compliance with all building codes, ` and Incorporate site conditions. l EXURB STUDIO, LLc 1038 MEADOW BEND LOOP N. GRAPEVINE, TX 16051 PHONE: 214-619-3580 EMAIL: IWOOEXURBSTUD IO.COM 0 Li m X W 3 3 z t Q LU Y X U w w LU CD (3 Z } LU U 0 � REVISIONS 1. 2. 3. 4. 1 < DATE: 2/16/26 DRAWN BY: EXS CHECK BY: EXS PROJECT NO. WARE GARAGE SHE NurrBER 1.2 GENERAL CONSTRUCTION NOTE5: 1. OWNER / CLIENT RESPONSIBILITIES: REFERENCE IS MADE THROUGHOUT THESE GENERAL NOTES TO RESPONSIBILITIES AND STANDARDS OF CARE TO BE FULFILLED BY THOSE PROVIDING SERVICES IN THE DEVELOPMENT AND CONSTRUCTION OF THIS PROJECT. OWNER / CLIENT SHALL BE RESPONSIBLE FOR ADHERENCE TO THOSE REQUIRMENTS BY THE OWNER, BUILDER, GENERAL CONTRACTOR, SUBCONTRACTORS AND OTHER PROFESSIONAL CONSULTANTS NOT RETAINED BY THE DESIGNER. 2. PERMIT SET: THIS SET OF PLANS IS SUFFICIENT TO OBTAIN BUILDING PERMIT, HOWEVER, ALL MATERIALS AND METHODS OF CONSTRUCTION NECESSARY TO COMPLETE THE PROJECT ARE NOT NECESSARILY DESCRIBED. THE PLANS DELINEATE AND DESCRIBE ONLY LOCATIONS, DIMENSIONS, TYPES OF MATERIALS AND GENERAL METHODS OF ASSEMBLING OR FASTENING. SPECIFICATION OF PARTICULAR PRODUCTS OR MATERIALS IS TO BE COORDINATED BY THE CONTRACTOR AND APPROVED BY THE OWNER. THE IMPLEMENTATION OF THESE PLANS REQUIRES AN OWNER / CLIENT / CONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE APPLICABLE BUILDING CODES AND METHODS OF CONSTRUCTION SPECIFIC TO THIS PRODUCT TYPE AND TYPE OF CONSTRUCTION. 3. BUILDING MAINTENANCE: THE EXPOSED MATERIALS USED IN THE CONSTRUCTION OF THIS PROJECT WILL DETERIORATE AS THE COMPLETED PROJECT AGES UNLESS PROPERLY AND ROUTINELY MAINTAINED. THE OWNER / CLIENT / CONTRACTOR SHALL PROVIDE OR CAUSE THE DEVELOPMENT OF A PLAN TO KEEP THESE EXPOSED MATERIALS PROTECTED AND MAINTAINED THROUGH COMPLETION OF THIS PROJECT. 4. ALL CONSTRUCTION SHALL COMPLY WITH THE MOST STRINGENT REQUIREMENTS OF ALL CURRENT APPLICABLE CITY, COUNTY, STATE AND FEDERAL LAUDS, RULES, CODES, ORDINANCES AND REGULATIONS. IF THE GENERAL CONTRACTOR OR ANY SUBCONTRACTOR PERFORMS ANY WORK IN CONFLICT WITH THE ABOVE MENTIONED LAUDS, RULES, CODES, ORDINANCES AND REGULATIONS, THEN THE CONTRACTOR IN VIOLATION SHALL BEAR ALL COSTS OF REPAIR ARISING OUT OF THE NON -CONFORMING WORK. 5. PERMITS: THE GENERAL BUILDING PERMIT AND PLAN CHECK SHALL BE SECURED AND PAID FOR BY THE OWNER / CLIENT. ALL OTHER PERMITS SHALL BE SECURED AND PAID FOR BY THE SUBCONTRACTOR DIRECTLY RESPONSIBLE. 6. NAMED PRODUCTS: THE DESIGNER MAKES NO GUARANTEE FOR THE PRODUCTS IDENTIFIED BY TRADE NAME OR MANUFACTURER. -1. SCOPE: THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL FURNISH ALL LABOR, EQUIPMENT AND MATERIAL INDICATED ON THE PLANS AND REASONABLY INFERRED OR REQUIRED BY THE APPLICABLE CODES. S. SUBSTITUTION: THE GENERAL CONTRACTOR AND ANY SUBCONTRACTORS SHALL NOT MAKE ANY STRUCTURAL SUBSTITUTIONS OR CHANGES WITHOUT PRIOR WRITTEN AUTHORIZATION FROM THE STRUCTURAL ENGINEER. g. CHANGES: ANY ADDITION, DELETION OR CHANGE IN THE SCOPE OF THE WORK DESCRIBED BY THE PLANS SHALL BE BY WRITTEN CHANGE ORDER ONLY. ANY APPROVAL FROM THE BUILDING OFFICIAL FOR A CHANGE IN THE WORK SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 10. INTENTION: THE GENERAL CONTRACTOR SHALL ENSURE THAT ALL LABOR, MATERIALS, EQUIPMENT AND TRANSPORTATION SHALL BE INCLUDED IN THE WORK FOR THE COMPLETE EXECUTION OF THE PROJECT. THE DESIGNER SHALL NOT BE RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION. 11. REVIEW OF DRAWINGS: THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL REVIEW THE FULL CONTENT OF THE PLANS FOR DISCREPANCIES AND OMISSIONS PRIOR TO COMMENCEMENT OF WORK. THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL BE RESPONSIBLE FOR ANY WORK NOT IN CONFORMANCE WITH THE PLANS OR IN CONFLICT WITH ANY CODE. 12. USE OF DRAWINGS: DIMENSIONS TAKE PRECEDENCE OVER SCALED MEASUREMENTS. DETAILS AND SECTIONS ON THE DRAWINGS ARE SHOWN AT SPECIFIC LOCATIONS AND ARE INTENDED TO SHOW GENERAL REQUIREMENTS THROUGHOUT. DETAILS NOTED "TYPICAL" IMPLY ALL LIKE CONDITIONS TREATED SIMILARLY, UNLESS NOTED OTHERWISE. THE BUILDING DETAILS SHOWN ARE INTENDED TO FURTHER ILLUSTRATE THE VISUAL DESIGN CONCEPT AND THE MINIMUM RECOMMENDED WEATHER PROTECTION FOR THE PROJECT. BUILDING CODE REQUIREMENTS, STRUCTURAL CONSIDERATIONS, TRADE ASSOCIATION MANUALS AND PUBLICATIONS AND PRODUCT MANUFACTURER'S WRITTEN INSTRUCTIONS SHALL ALSO BE CONSIDERED IN ORDER TO COMPLETE THE CONSTRUCTION OF THE DETAILS, AND IN SOME CASES MAY SUPERSEDE THE DETAILS. 13. APPROVED DRAWINGS: THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK BETWEEN THE DIFFERENT SUBCONTRACTORS AND REQUIRING ALL SUBCONTRACTORS TO USE THE MOST CURRENT BUILDING DEPARTMENT APPROVED SET OF CONSTRUCTION PLANS. 14. CLEAN UP. ALL TRADES SHALL, AT ALL TIMES, KEEP THE PREMISES FREE FROM ACCUMULATION OF WASTE MATERIALS OR RUBBISH CAUSED BY THEIR WORK. SUBCONTRACTORS SHALL REMOVE ALL RUBBISH, TOOLS, SCAFFOLDING AND SURPLUS MATERIALS AND LEAVE THE JOB IN BROOM -CLEAN CONDITION. ALL FIXTURES, EQUIPMENT, GLAZING, FLOORS, ETC., SHALL BE LEFT CLEAN AND READY FOR OCCUPANCY UPON COMPLETION OF THE PROJECT. 15. STORAGE OF MATERIALS: THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR STORING THE MATERIALS ON THE SIT ACCORDING TO MATERIAL SUPPLIER'S OR MANUFACTURER'S INSTRUCTIONS. THE MATERIALS SHALL BE KEPT SECURE AND PROTECTED FROM MOISTURE, PESTS, AND VANDALS. ANY LOSS ARISING OUT OF MATERIALS STORED AT THE SITE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR OR SUBCONTRACTORS WHO STORED THE DAMAGE OR LOST MATERIALS. 16, THE GENERAL CONTRACTOR SHALL COORDINATE THE WORK WITH MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ALL NECESSARY OPENINGS AND PENETRATIONS THROUGH WALLS, CEILINGS AND FLOORS. Lim All documents hers attached are Copyrighted 202D by %� Exurrnnb�� Studio, Designer. The ROUGH CARPENTRY DEt"10L ITION / CONSTRUCTION NOTES an 'Iiot t:prep ed bg the Designer, and )Designer's office are Instruments of service. The Designer "I] be 1. FRAMING: doomed the author of these documents and retains all statutory, A. STUD WALLS PER APPLICABLE BUILDING CODE. 1. THE INTENT OF THE DEMOLITION PLANS IS TO SHOW THE common law, and other reserved rights including Copyright. TTn FULL HEIGHT WALLS SHALL HAVE CONTINUOUS STUDS FROM Designer's Design, all other GENERAL NATURE OF THE DEMOLITION SCOPE. THE documents rb and all other BOTTOM TO TOP PLATE. Designer and Designer's GENERAL CONTRACTOR IS RESPONSIBLE FOR VISITING THE office °hell not be reused by the B. CEILING JOISTS: PER APPLICABLE BUILDING CODE. JOB SITE AND VERIFYING THE EXISTING CONDITIONS 4 t►wnepr(ellerM.)orothersonany modineattIior s t th e�project or USE SOLID BRIDGING. DIMENSIONS. THE GENERAL CONTRACTOR SHOULD NOTIFY for completion of this project by ting C. BACKING: PROVIDE BACKING AT ALL PENDANT OR SIGNATURE DESIGN STUDIO IMMEDIATELY OF ANY from t' without permission o'part oftheFrom the Designer. SURFACE -MOUNTED ELECTRICAL FIXTURES, RAILS, GRAB BARS, abovemsnttoneddownsimilar DISCREPANCIES. �eNlod reproduced t without �g�r BATH ACCESSORIES, ETC. D. FIRE STOPPING: PER APPLICABLE BUILDING CODE. foranThe gsigneraebuiltfomthse 2. COORDINATE AND VERIFY WITH THE OWNER ALL ITEMS TO for any structure built from these E. STUD WALLS: PER APPLICABLE BUILDING CODE. ALL p� plans. Before co, or wont, the eMerif builder, or contractor B SALVAGED D PRIOR O DEMOLITION. O must verify all dimen.ton., verify STUDS TO HAVE FULL BEARING ON PLATE. ALL STUDS TO compliance with all building codes, BE 16" O.C. UNLESS NOTED OTHERWISE. STUDS TO BE SIZED 3. GENERAL CONTRACTOR IS TO MAINTAIN A SEPARATION and incorporate site conditions. PER REQUIREMENTS OF BUILDING CODE. BETWEEN AREAS WITHIN THE SCOPE OF WORK AND AREAS 10M ME6A=DMBD LOOP F. USE CONTINUOUS, FULL HEIGHT STUDS IN ACCORDANCE OUTSIDE OF THE SCOPE OF WORK. v 214-"b g- WITH THE HIGHEST STANDARD OF CONSTRUCTION AND EMAIL: INFOsEXURBBIT, jp I OCOM FRAMING PRACTICES. 4. CAUSE NO DAMAGE TO EXISTING CONSTRUCTION TO REMAIN. G. ALL ANGLED WALLS TO BE 45 DEGREES UNLESS NOTED TAKE CARE NOT TO ENCROACH ON ADJACENT OCCUPIED OTHERWISE. AREAS OR AREAS NOT WITHIN THE SCOPE OF WORK. H. BUILT UP ROOFS, WATERPROOF BALCONY DECKS AND PROTECT ALL EXISTING FINISHES, DOORS, FRAMES, ETC. EXTERIOR HORIZONTAL AREAS ARE TO FRAMED WITH SLOPE WHICH AREA TO REMAIN. TO ENSURE WATER DRAINAGE WITHOUT PONDING. I. PROVIDE CRICKETS AS INDICATED AND AS NECESSARY 5. USE ALL MEANS NECESSARY TO PREVENT THE SPREAD OF FOR PROPER WATER DRAINAGE AND TO REDIRECT CHANNELED DUST TO ADJACENT AREAS. OR RUNOFF WATER AWAY FROM VERTICAL SURFACES. J. PROVIDE BLOCKING WHERE REQUIRED TO PROVIDE 6. CONDUCT DEMOLITION OPERATIONS 4 THE REMOVAL OF UNIFORM SURFACES WHERE FLUSH JOISTS AND BEAMS ARE DEBRIS TO ENSURE MINIMUM INTERFERENCE WITH STREETS, DIFFERENT DEPTHS. WALKS, 4 OTHER ADJACENT OCCUPIED OR USED FACILITIES. K. USE MITERED JOINTS AT FASCIA SPLICES. COMPLY WITH LOCAL JURISDICTION REQUIREMENTS FOR L. ALL DIMENSIONS ARE GIVEN TO CENTER OF FRAMING, RECYCLING AND TREATMENT OF ITEMS TO BE RECYCLED. UNLESS OTHERWISE NOTED. 0 1. DISPOSE OF ALL DEMOLISHED OR REMOVED MATERIALS FM 0 LEGALLY OFF THE SITE. COMPLY WITH ALL LOCAL HAULING 'p 4 DISPOSAL REQUIREMENTS.in Ln FLOOR PLAN NOTES 8. EXURB STUDIO HAS NO KNOWLEDGE OF AND SHALL NOT BE m HELD LIABLE FOR ANY ASBESTOS OR OTHER HAZARDOUS I. ALL GAS OR WOOD -BURNING FIREPLACES WITHIN A DWELLING UNIT SHALL MATERIALS ON JOBSITE. THE CONTRACTOR SHALL in X COMPLY WITH THE INTERNATIONAL RESIDENTIAL CODE AND LOCAL AMENDMENTS. IMMEDIATELY ISOLATE THE AFFECTED AREA IF ASBESTOS W 2. SMOKE DETECTORS SHALL BE INSTALLED AT LOCATIONS REQUIRED BY OR OTHER HAZARDOUS MATERIAL ARE DISCOVERED 3 THE INTERNATIONAL RESIDENTIAL CODE AND SHALL RECEIVE THEIR PRIMARY DURING CONSTRUCTION. NOTIFY OWNER FOR FURTHER ly 3 POWER FROM BUILDING WIRING AND SHALL BE EQUIPPED WITH A BATTERY BACK UP. INSTRUCTION BEFORE PROCEEDING WITH OTHER WORK. 3. UNDER NO CIRCUMSTANCES IS THE USE OF WATER RESISTANT GYP. BD. "GREEN BOARD" AS BACKING FOR TILE OR WALL PANELS IN ANY POTENTIALLY g. MAINTAIN EXISTING UTILITIES TO REMAIN IN SERVICE AND "WET" AREA TO BE USED. USE ONLY PANELS RATED FOR MOISTURE 4 MOLD PROTECT AGAINST DAMAGE DURING DEMOLITION RESISTANCE. SHOWER STALLS SHALL BE FURNISHED WITH A HARD, NON ABSORBENT OPERATIONS. MATERIAL. 4. PROVIDE A MINIMUM 30"x22" ATTIC ACCESS OPENING WITH A MINIMUM HEADROOM 10. UPON COMPLETION, CLEAN THE ENTIRE AREA OF CLEARANCE OF 30" WHEN MECHANICAL EQUIPMENT IS INSTALLED IN THE ATTIC SPACE. DEMOLITION TO A TIDY, UNIFORM CONDITION REMOVING ALL THE OPENING SHALL BE LOCATED IN A HALLWAY, CORRIDOR OR OTHER READILY DEBRIS, DUST PARTITIONS 4 ASSOCIATED MATERIALS USED ACCESSIBLE LOCATION PER THE INTERNATIONAL RESIDENTIAL CODE. DURING THE DEMOLITION. CLEAN ALL AREAS IMPACTED BY 5. WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO RESIST DISPLACEMENT. THE DEMOLITION, INCLUDING BUT NOT LIMITED TO, ADJACENT STRAPPING SHALL BE AT POINTS WITHIN THE UPPER � AND LOUDER � OF IT'S VERTICAL OCCUPIED AREAS AND AREAS NOT WITHIN THE SCOPE OF DIMENSION. AT THE LOUDER POINT, MAINTAIN A MIN OF 4" CLEARANCE ABOVE THE WORK. WATERHEATER CONTROLS. 6. GAS WATER HEATERS AND FURNACES SHALL BE LOCATED ON A RIGID RAISED 11. COMPLY WITH ALL STANDARD LOCAL, NATIONAL, STATE AND PLATFORM A MINIMUM OF 18" HIGH. FEDERAL SAFETY REQUIREMENTS FOR -1. SAFETY GLAZING TO BE PROVIDED AT THE FOLLOWING AREAS: DEMOLITION/CONSTRUCTION. A. SLIDING OR SWINGING DOORS 12, THE INTENT OF THESE DRAWINGS HEREIN IS TO REPRESENT A Q B. TUB AND OR SHOWER ENCLOSURES AND GLAZING IN WALLS LESS THAN 60" COMPLETE WORKING SYSTEM. ALL CONTRACTORS SHALL BE W Y X ABOVE THE STANDING SURFACE OF TUBS OR SHOWERS. RESPONSIBLE FOR PROVIDING AND INSTALLING ALL C. GLAZING WITHIN 24" OF THE SWING OF A DOOR, COMPONENTS NECESSARY TO PROVIDE THE DESIGN INTENT, D. GLAZING IN WALLS ENCLOSING STAIRWAY LANDINGS OR WITHIN 5' OF THE WHETHER SHOWN OR NOT ON THE DRAWINGS. fQ U BOTTOM AND TOP OF STAIRWAYS WHERE THE BOTTOM EDGE OF GLASS IS LESS THAN O w E. GLAZING WI "" WITHIN 15AOF IT E FLOOR. E Q O U F. ANY INDIVIDUAL PANE GREATER THAN 9 SQ.FT. ELECTRICAL NOTE5 1. ALL CONVENIENCE OUTLETS WITH SWITCHES TO BE SWITCHED AT TOP ONLY. 2. ALL SWITCHES TO BE 4'-6" ABOVE FINISH FLOOR TO CENTERLINE OF SWITCH UNLESS OTHERWISE NOTED. 3. ALL CONVENIENCE OUTLETS ARE 1'-0" ABOVE FINISH FLOOR TO CENTERLINE OF OUTLET UNLESS OTHERWISE NOTED. EXCEPTION - LOCATE CONVENIENCE OUTLETS HORIZONTALLY UNDER WINDOWS 4" ABOVE FINISHED FLOOR 4. ALL BRACKET FIXTURES TO BE AT 6'-6" ABOVE FINISH FLOOR TO CENTER OF FIXTURE. 5. SMOKE DETECTORS SHALL BE LOCATED WITHIN 12" OF THE HIGHEST POINT ON THE CEILING. 6. VERIFY LOCATION OF ALL RECEPTACLES FOR APPLIANCES WITH MANUFACTURER'S SPECIFICATIONS. I. ELECTRICAL OUTLET BOXES TO BE SEPARATED A MAXIMUM OF 12'-0" AND ARE TO COMPLY WITH THE NATIONAL ELECTRICAL CODE AND LOCAL CODES. ELECTRICAL OUTLET BOXES TO BE SEPARATED 24" HORIZONTALLY ON ALL PARTY WALLS. G.F.I. CIRCUIT TO BE PROVIDED AT ALL LOCATIONS WHERE REQUIRED BY CODE. EEVISIONO 1. 2. 3. ..1 � C DATE: 2/16/26 PRAWN EXS CHECK BY: EXS PROJECT NO. WARE GARAGE 11. THE GENERAL CONTRACTOR SHALL VERIFY ALL PROJECT SITE CONDITIONS AND RELATED DIMENIONS. STANDARD CONSTRUCTION NOTES 'a'2 101 CROSS C SEEK GA SAG =.AD DI-IO V F j4, ........................... ALIAKSEI PATSEVICH GN002. ABBREVIATIONS ABBREVIATION DESCRIPTION FRT FIRE RETARDANT TREATED RCSC RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS @ AT FS FAR SIDE RD ROOF DRAIN = EQUAL FT FOOT REC RECOMMENDATIONS # POUNDS (LBS.) FIG FOOTING REF REFERENCE OR REFER A.B. OR AB ANCHOR BOLT GA GAUGE REINF REINFORCEMENT A/C OR AC AIR CONDITIONING GALV GALVANIZED REQ'D OR REQD REQUIRED ABV ABOVE GB GRADE BEAM REQ'S OR REQS REQUIREMENTS ACI AMERICAN CONCRETE INSTITUTE GC GENERAL CONTRACTOR REQ'T OR REQT REQUIREMENT ADDL ADDITIONAL GEOTECHNICAL ENGINEER OF GER RGD RIGID A.F.F. OR AFF ABOVE FINISH FLOOR RECORD REGISTERED PROFESSIONAL RPT GN GENERAL NOTE(S) TECHNICIAN AHJ AUTHORITY HAVING JURISDICTION RTU ROOF TOP UNIT GR GRADE AISC AMERICAN INSTITUTE OF STEEL S/ SIDE OF CONSTRUCTION GYP OR GWB GYPSUM WALL BOARD ALT ALTERNATE H OR HT HEIGHT SCHED SCHEDULE ALUM ALUMINUM HDG HOT -DIPPED GALVANIZED SOS SELF DRILLING SCREWS AOR ARCHITECT OF RECORD HDR HEADER SECT SECTION APPROX APPROXIMATE SF SQUARE FOOT HGR HANGER ARCH ARCHITECT OR ARCHITECTURAL SHT SHEET HI HIGH AMERICAN WOOD PROTECTION AWPA ACCOCIA71ON HI & LO HIGH AND LOW SHTG SHEATHING AWS AMERICAN WELDING SOCIETY HOR HORIZONTAL SIM SIMILAR B.F. OR BF BOTTOM FLUSH HS OR H.S. HEADED STUD SLBB SHORT LEG BACK TO BACK BLDG BUILDING HSS HOLLOW STRUCTURAL SECTION S.O.G. OR SOG SLAB ON GRADE BLDR BUILDER HVAC HEATING, VENTILATION, AND AIR SP SPACE OR SPACING BLKG BLOCKING CONDITIONING SPEC SPECIFICATION ICF INSULATED CONCRETE FORMS BM BEAM ID OR I.D. INSIDE DIAMETER S.S. OR SS STAINLESS STEEL BOT BOTTOMIF SSMA STEEL STUD MANUFACTURERASSOCIATION OR I.F. INSIDE FACE B.P. OR BP BASE PLATE IN INCH STD STANDARD BRG BEARING INFO [FORMATION STIFF STIFFENER BRK BRICK INT INTERIOR STIRR STIRRUPS BTWN BETWEEN INTERN INTERMEDIATE STL STEEL BSMT BASEMENT INS ORINSUL INSULATION STR. OR STRUC. STRUCTURAL B/ BOTTOM OF IT JOINT SUB SUBCONTRACTOR BOT BOTTOM SQ SQUARE JST JOIST CANT CANTILEVER K KIPS (1000 LBS. OR 1000#) S.W. OR SW SHEAR WALL CFM COLD FORMED METAL KLF KIP PER LINEAR FOOT SYM SYMMETRICAL C.J. OR Cl CONTROL JOINT CJP COMPLETE JOINT PENETRATION K/O KNOCK OUT T/ TOP OF C.L. OR CL CENTERLINE K5F KIP PER SQUARE FOOT T&B TOP AND BOT CLG CEILING L LENGTH T&G TONGUE AND GROOVE CLR CLEAR LBS POUNDS TEMP TEMPERATURE CMU CONCRETE MASONRY UNIT LOC LOCATION T.F. OR TF TOP FLUSH COL COLUMN LONG LONG OR LONGITUDINAL THK THICK OR THICKNESS COMP COMPRESSION OR COMPRESSIBLE LLBB LONG LEG BACK TO BACK TH RD THREADED ROD CONC CONCRETE LLH LONG LEG HORIZONTAL T.J. OR TJ TRIPLE JOIST CONNX CONNECTION LLV LONG LEG VERTICAL TOC OR T.O.C. TOP OF CONCRETE CONSTR CONSTRUCTION LB OR # POUND TOS OR T.O.S. TOP OF STEEL CONT CONTINUOUS LO LOW TOW OR T.O.W. TOP OF WALL CONTR CONTRACTOR LT LIGHT TPI TRUSS PLATE INSTITUTE COORD COORDINATE CONCRETE REINFORCING STEEL LW OR LT WT LIGHTWEIGHT TR OR TRANS TRANSVERSE CRSI INSTITUTE LWC LIGHTWEIGHT CONCRETE TYP TYPICAL CTR CENTER MAS MASONRY LILT ULTIMATE DB DROPPED BEAM MAIL MATERIAL U.N.O OR LINO UNLESS NOTED OTHERWISE DBL DOUBLE MAX MAXIMUM U.P.A. OR UPA UNDER POST ABOVE DEG OR ° DEGREE MC MOMENT CONNECTION U.W.A. OR UWA UNDER WALL ABOVE DET DETAIL MECH MECHANICAL V.C.B. OR VCB VERTICAL CRUSH BLOCKING DIA OR to 0 DIAMETER MECHANICAL, ELECTRICAL, VERT VERTICAL DIAG DIAGONAL MEP PLUMBING SPECIALTY SUB DIM DIMENSION MEZZ MEZZANINE V.I.F. OR VIF VERIFY IN FIELD D.J. OR DJ DOUBLE JOIST MID MIDDLE VNR VENEER DN DOWN MIN MINIMUM W/ WITH D.S. OR DS DOWN SPOUT MISC MISCELLANEOUS W/O WITHOUT DTL DETAIL MNFR OR MFR MANUFACTURER WD WOOD DWG DRAWING MTL METAL WF WIDE FLANGE BEAM DWL DOWEL NA OR N/A NOT APPLICABLE W.P. OR WP WORK POINT EA EACH N.B. OR NB NON -BEARING VJRB WEATHER -RESISTIVE BARRIER E.F. OR EF EACH FACE NIC OR N.I.C. NOT IN CONTRACT WS WATER STOP EIFS EXTERIOR INSULATION AND FINISH NISI NATIONAL INSTITUTE OF W.S.P. OR WSP WOOD STRUCTURAL PANEL SYSTEM STANDARDS AND TECHNOLOGY E.J ORE] EXPANSION JOINT NHR OR N.H.R. NO HEADER REQUIRED WT WEIGHT ELEC ELECTRICAL NO. OR # NUMBER W.W.F. OR WNIF WELDED WIRE FABRIC EL ELEVATION NOM NOMINAL XPS EXTRUDED POLYSTERENE ELEV ELEVATOR NS NEAR SIDE EMBED EMBEDDED OR EMBEDMENT NS & FS NEAR SIDE AND FAR SIDE E.N. OR EN OR P.E.N PANEL EDGE NAILING N.T.S. OR NTS NOT TO SCALE LOAD TYPE ABBREVIATIONS: ENG ENGINEER NWC NORMAL WEIGHT CONCRETE ASO ALLOWABLE STRESS DESIGN E.O.R. OR FOR ENGINEER OF RECORD LOAD AND RESISTANCE FACTOR O.C. OR OC ON -CENTER LRFD DESIGN E.P. OR EP EMBED PLATE DL DEAD LOAD OD OUTSIDE DIAMETER EPS EXPANDED POLYSTERENE ET CETERA (AND OTHER SIMILAR OF OUTSIDE FACE LL LIVE LOAD ETC THINGS) OPNG OPENING RL ROOF LOAD EQ EQUAL OPP OPPOSITE SL SNOW LOAD EQUIP EQUIPMENT EL SEISMIC LOAD PARAL PARALLEL E.S. OR ES EACH SIDE SDL SUPERIMPOSED DEAD LOAD PERP PERPENDICULAR E,1V. OR EW EACH 'NAY PCF POUNDS PER CUBIC FOOT TL TOTAL LOAD EXIST OR (E) EXISTING EXP EXPANSION PIP PARTIAL JOINT PENETRATION WL WIND LOAD EXT EXTERIOR PL PLATE FAB FABRICATOR OR FABRICATE PLBG PLUMBING WOOD SPECIES ABBREVIATIONS: F/ FACE OF PLF POUNDS PER LINEAR FOOT AYC ALASKAN YELLOW CEDAR F.B. OR FB FLUSH BEAM PLWD PLYWOOD DF DOUGLAS FIR (SOUTH) FD FLOOR DRAIN POLYISO POLY ISOCYAN U RATE INSULATION DFL DOUGLAS FIR LARCH F.F.E. OR FFE FINISHED FLOOR ELEVATION PREFAB PREFABRICATED ERC EASTERN RED CEDAR FIN FINISH PRO] PROJECT OR PROJECTION HF HEM FIR FL OR FLR FLOOR PSF POUNDS PER SQUARE FOOT SPF SPRUCE PINE FIR FL.FR. OR FLFR FLOOR FRAMING PSI POUNDS PER SQUARE INCH SYP SOUTHERN YELLOW PINE FLUHG FLASHING PRESSURE TREATED (LUMBER) PT POST TENSIONED (CONCRETE) WRC WESTERN RED CEDAR FND OR FDN FOUNDATION PVMT PAVEMENT F.O.C. FACE OF CONCRETE QTY QUANTITY ENGINEERED LUMBER TYPES: F.0.5 FACE OF STEEL R RADIUS GLB OR GLULAM GLUE -LAMINATED TIMBER FP FIREPLACE R.O. OR RO ROUGH OPENING LVL LAMINATED VENEER LUMBER FR OR FRMG FRAMING RAF RAFTER LSL LAMINATED STRAND LUMBER RESEARCH COUNCIL ON RCSC PSL PARALLEL STRAND LUMBER FRM FRAME STRUCTURAL CONNECTIONS S26129 I2:191b] 4146 0 49hrolA z r_r i col► PROJECT ADDRESS 101 CROSS CREEK DR GRAPEVINE, TX ARCHITECT EXURB STUDIO, LLC 1038 MEADOW BEND LOOP N 214-679-3580 INFO@EXURBSTUDIO.COM STRUCTURAL ENGINEER L120 ENGINEERING & DESIGN P.O. BOX 1447 GRAPEVINE, TX 76099 PHONE: (214) 625-2819 CONTACT: ALIAKSEI PATSEVICH, PE DESIGN CRITERIA APPLICABLE INTERNATIONAL BUILDING AND/OR RESIDENTIAL CODE EDITION: 2021 AND AMENDMENTS AS ADOPTED BY THE REVIEWING AGENCY/COUNTY. RISK CATEGORY ..................II BASIC WIND SPEED ..................115 MPH WIND EXPOSURE ... B TOPOGRAPHIC FACTOR Kzt...1.0 SEISMIC DESIGN CATEGORY ...... B SITE CLASS .... D SS ... 0.12 51...0.059 DEAD LOADS AS SPECIFIED IN THE "DESIGN WEIGHTS OF ASSEMBLIES" NOTE 116 OF THE GENERAL STRUCTURAL NOTES. LIVE LOADS AND AS SPECIFIED IN THE "LIVE LOADS" NOTE 117 OF THE GENERAL STRUCTURAL NOTES DEFLECTION CRITERIA AS SPECIFIED IN THE "DEFLECTION LIMITS" NOTE 118 OF GENERAL STRUCTURAL NOTES. GROUND SNOW LOAD .... 12 PSF GEOTECHNICAL REPORT PTI DESIGN PARAMETERS: DIFFERENTIAL SWELL FOR EDGE LIFT, = DIFFERENTIAL SWELL FOR CENETER LIFT, = EDGE MOISTURE VARIATION, EDGE LIFT, = EDGE MOISTURE VARIATION, CENTER LIFT, = LATERAL EARTH PRESSURE DESIGN PARAMETERS: ACTIVE .... 35 PSF/FT AT REST ... 55 PSF/FT PASSIVE.... 250 PSF/FT COEFFICIENT OF BASE FRICTION: 0.30 q 130521 �P�,� �'•���ENSE�••'•� �� ONAL ENG w co z Dz0 W 03 r� Z V � W Z wg Za 00W J M O1 57 C] U% 1p U ,--I 4zk x Cj� LLI w � z z_ J w U Lu a z W X � O U .-1 _J X O Lu m cn L Q 00 fV Lr) fV tD REVISIONS 0 DATE BY PIER DESIGN VALUES: PROJECT NAME END BEARING.... SKIN FRICTION.... 101 CROSS CREEK UPLIFT SKIN FRICTION.... OVER TOP XX FEET GARAGE ADDITION SHEET INDEX S-100 COVER SHEET S-101 GENERAL STRUCTURAL NOTES PROJECT ADDRESS S-301 FRAMING NOTES AND DETAILS 101 CROSS CREEK DR S-302 FRAMING NOTES AND DETAILS S-311 FIRST LEVEL CEILING FRAMING PLAN GRAPEVINE, TX S-312 ROOF FRAMING PLAN S-401 WALL BRACING NOTES DETAILS AND SCHEDULES PROJECT NUMBER S-411 FIRST FLOOR SHEAR WALL PLAN S-412 SECOND FLOOR SHEAR WALL PLAN S26129 CHECKED BY - AP G N 001. LEGEND SHEET DATE - 05/04/2026 1 3/4" X 14" LVL DTL. - SECTION CALLOUT PER PLAN SCALE I - WOOD BEAM (EXAMPLE) 5HTLTJ . - HANGER AS REQ'D DTL, 24X36 SHEET:1/2"=1'-0" C— - — - WOOD JOIST Ste' - HANGER AS REQ'D I - PLAN DETAIL CALLOUT PER PLAN Lv W10X15 - STEEL BEAM (EXAMPLE) - - MOMENT CONNECTION z - TRUSS OR JOIST F_ SPREAD FOOTING (n o (LENGTH X WIDTH X DEPTH) EXTENT OF SIMILAR �_o F SPACED JOIST OR �F� Z o TRUSSES -�o HOLDOWN OR VERTICAL STRAP - HANGER AS REQ'D 9 OI GT -GIRDER TRUSS J - STEP AT TOP tea./ ROOF BRACE STEP AT BOT - HIGH END r� SHEAR WALL CALLOUT. - LOW END SW6 REFER TO SHEARWALL SCHEDULE INDICATES SHEARWALL CS16 - HORIZONTAL STRAP LOCATION AND EXTENTS - BLOCKED DIAPHRAGM 99'-6" - SPOT ELEVATION PIER CALLOUT ® -WOOD STUD OR POST XX / X / X W O W O 1 JACK - INDICATES THE NUMBER OF KING AND KT/PIER EL 0 /_2 KING JACK STUDS AT SIDE OF OPENING PENETRATION INTO a IU) UO GRAY LIMESTONE (FT) cl� cl� V.C.B. - VERTICAL CRUSH BLOCKING ALIGNED DIA (IN) U Lu UNDER POINT LOAD ABOVE TO MATCH Lu QUANTITY AND SIZE OF SUPPORT ABOVE 0 Lu U = GN100. GENERAL STRUCTURAL NOTES 100. GENERAL CONDITIONS 100.1. THESE STRUCTURAL PLANS ARE BASED ON INFORMATION PROVIDED TO THE ENGINEER OF RECORD (EOR). THE FOR SHALL BE ENTITLED TO RELY ON THE ACCURACY AND COMPLETENESS OF THIS INFORMATION IN THE PREPARATION OF THE CONSTRUCTION DOCUMENTS. 100.2. THE CONTRACTOR SHALL REVIEW THE STRUCTURAL DRAWINGS IN THEIR ENTIRETY PRIOR TO PROCEEDING WITH ANY WORK. ANY DISCREPANCIES CONFLICTS OR OMISSIONS IDENTIFIED BETWEEN STRUCTURAL DRAWINGS AND ANY OTHER PROJECT DOCUMENTS SHALL BE REPORTED IN WRITING TO THE ARCHITECT THE FOR AND ALL OTHER APPLICABLE PARTIES BEFORE CONSTRUCTION OF THE AFFECTED WORK BEGINS. THIS NOTIFICATION APPLIES THROUGHOUT ALL PHASES OF CONSTRUCTION AND IS REFERENCED THROUGHOUT THESE NOTES. 100.3. ALL CONSTRUCTION SHALL BE DONE WITH MATERIALS, METHODS, AND WORKMANSHIP ACCEPTED AS GOOD PRACTICE BY THE CONSTRUCTION INDUSTRY IN CONFORMANCE TO THE PROVISIONS OF THE INTERNATIONAL BUILDING CODE, AND STANDARDS REFERENCED THEREIN, AND ALL OTHER REGULATING AGENCIES EXERCISING AUTHORITY OVER ANY PORTION OF THE WORK. 100.4. IN CASE OF CONFLICT, SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE THE NOTES, DRAWINGS, AND/OR SPECIFICATIONS DIFFER, THE MORE STRINGENT REQUIREMENT SHALL APPLY. IF A SPECIFIC DETAIL IS NOT SHOWN FOR ANY PART OF THE WORK, THE CONSTRUCTION SHALL BE THE SAME AS FOR SIMILAR WORK. 100.5. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT AND THE FOR OF ANY CONDITION THAT MAY ENDANGER OR CAUSE DISTRESS TO THE STRUCTURE. SEE NOTE 100.2 FOR GENERAL NOTIFICATION REQUIREMENTS. 100.6. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THEIR WORK AND SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS METHODS UES TECHNIQ SEQUENCES AND PROCEDURES. 100.7. THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION. THIS INCLUDES ALL MEASURES NECESSARY TO SAFELY SUPPORT STRUCTURAL COMPONENTS UNTIL THE PERMANENT STRUCTURAL SYSTEM IS FULLY IN PLACE AND SELF-SUPPORTING. 100.7.1. WHERE APPLICABLE, THE CONTRACTOR SHALL ENGAGE A QUALIFIED ENGINEER TO DESIGN AND CERTIFY TEMPORARY SHORING SYSTEMS, PARTICULARLY WHEN REMOVING OR MODIFYING EXISTING STRUCTURAL ELEMENTS OR WHERE SIGNIFICANT CONSTRUCTION SEQUENCING IS INVOLVED. 100.8. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR JOBSITE SAFETY. THE ENGINEER HAS NOT BEEN RETAINED TO PROVIDE SERVICES RELATED TO CONSTRUCTION SAFETY MEASURES, MEANS, METHODS, OR PROCEDURES. SITE VISITS BY THE ENGINEER SHALL NOT BE CONSTRUED AS SUPERVISION OF CONSTRUCTION ACTIVITIES OR IMPLY RESPONSIBILITY FOR JOBSITE SAFETY OR WORKING CONDITIONS. 100.9. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND THE FOR IN WRITING OF ALL PROPOSED FIELD CHANGES PRIOR TO INSTALLATION. 100.10. THESE GENERAL STRUCTURAL NOTES SHALL APPLY ONLY TO THE WORK PERFORMED BY THE FOR WITHIN THE DEFINED SCOPE OF THE EOR'S SERVICES. IF ANY GENERAL NOTE REFERENCES WORK THAT IS COVERED IN WHOLE OR IN PART BY ANOTHER TRADE, THE SPECIFICATIONS AND REQUIREMENTS OF THAT TRADE SHALL GOVERN FOR THE APPLICABLE SCOPE OF WORK. 100.11. THE CONTRACTOR SHALL MAINTAIN A COMPLETE RECORD OF ALL CONSTRUCTION -RELATED DOCUMENTATION, INCLUDING BUT NOT LIMITED TO MATERIAL TESTING RESULTS, PLACEMENT LOGS, INSPECTION REPORTS, AND SUBMITTALS, FOR THE DURATION OF THE APPLICABLE WARRANTY PERIOD. ALL SUCH RECORDS SHALL BE MADE AVAILABLE TO THE FOR UPON REQUEST. 100.12. 1T IS THE CONTRACTOR'S RESPONSIBILITY TO IDENTIFY ANY SPECIAL DOCUMENTATION REQUIRED BY A LOCAL JURISDICTION OR A THIRD PARTY. THIS INCLUDES ANY PROGRAM ENROLLMENT, INCLUDING BUT NOT LIMITED TO, A HOMEBUYER WARRANTY PROGRAM AND THE TEXAS DEPARTMENT OF INSURANCE (TDI). IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE ENGINEER OF THESE SPECIAL REQUIREMENTS IN A TIMELY MANNER. 101. MATERIAL STORAGE 101.1. ALL STRUCTURAL MATERIALS SHALL BE STORED IN A MANNER THAT PROTECTS THEM FROM MOISTURE, DIRECT SUNLIGHT, MECHANICAL DAMAGE, AND OTHER CONDITIONS THAT MAY ADVERSELY AFFECT THEIR STRUCTURAL PROPERTIES OR FITNESS FOR USE. UNLESS OTHERWISE SPECIFIED IN THE MATERIAL -SPECIFIC SECTIONS OF THESE NOTES, ALL MATERIALS SHALL BE: 101.1.1. STORED OFF THE GROUND ON LEVEL SUPPORTS OR BLOCKING TO PREVENT DIRECT CONTACT WITH SOIL OR STANDING WATER. 101.1.2. COVERED OR PROTECTED FROM DIRECT MOISTURE AND PRECIPITATION DURING STORAGE AND CONSTRUCTION. 101.1.3. SUPPORTED TO PREVENT WARPING, BOWING, OR PERMANENT DEFORMATION DURING STORAGE. 101.1.4. INSPECTED PRIOR TO INSTALLATION. MATERIALS THAT HAVE BEEN DAMAGED, EXCESSIVELY WETTED, WARPED, OR OTHERWISE COMPROMISED DURING STORAGE SHALL NOT BE INSTALLED AND SHALL BE REMOVED FROM THE JOBSITE. 101.1.5. STORED AND HANDLED IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED REQUIREMENTS WHERE APPLICABLE. 102. STRUCTURAL STEEL 102.1. ALL STRUCTURAL STEEL SHALL CONFORM TO THE LATEST EDITION OF AISC SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS AND APPLICABLE LOCAL BUILDING CODES. ALL MEMBERS SHALL BE STRAIGHT, TRUE TO LINE, AND FREE FROM DEFECTS. 102.2. STRUCTURAL STEEL SHAPES SHALL CONFORM TO THE FOLLOWING STANDARDS UNLESS OTHERWISE NOTED: 102.2.1. WIDE FLANGE (W-SHAPES): ASTM A992, FY = 50 KSI 102.2.2. CHANNELS, ANGLES, PLATES: ASTM A36, FY = 36 KSI 102.2.3. HOLLOW STRUCTURAL SECTIONS (HSS): ASTM A500 GRADE B, FY = 46 KSI 102.2.4. BOLTS: ASTM F3125 GRADE A325 OR A490, AS SPECIFIED 102.2.5. WELDS: PER AWS D1.1 USING E70XX ELECTRODES 102.3. ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS IN ACCORDANCE WITH AWS D1.1. WELDS SHALL BE CONTINUOUS UNLESS OTHERWISE INDICATED. WELDS NOT SPECIFICALLY DETAILED SHALL BE A MINIMUM 1/4" CONTINUOUS FILLET WELD. USE DRY E70 ELECTRODES FOR ALL FIELD WELDING. 102.4. ALL BOLTED CONNECTIONS SHALL BE MADE WITH HIGH -STRENGTH BOLTS UNLESS NOTED OTHERWISE. BOLTS SHALL BE TENSIONED USING TURN -OF -NUT OR CALIBRATED WRENCH METHODS PER RCSC GUIDELINES. 102.5. ALL STRUCTURAL STEEL SHALL BE SHOP -PRIMED WITH A RUST -INHIBITIVE PRIMER UNLESS NOTED AS GALVANIZED OR OTHERWISE PROTECTED. SURFACES TO BE FIELD -WELDED SHALL BE FREE OF PRIMER IN THE WELD ZONE. 102.6. FIELD MODIFICATIONS, INCLUDING BUT NOT LIMITED TO CUTTING, NOTCHING, DRILLING, OR PENETRATING OF STRUCTURAL STEEL MEMBERS, ARE NOT PERMITTED UNLESS EXPLICITLY SHOWN ON THE APPROVED DRAWINGS OR AUTHORIZED BY PRIOR WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER OF RECORD. 102.7. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO FABRICATION. DISCREPANCIES SHALL BE REPORTED PER NOTE 100.2. 102.8. THE CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AND BRACING AS REQUIRED TO ENSURE STABILITY OF THE STEEL FRAME DURING ERECTION. DO NOT REMOVE TEMPORARY SUPPORTS UNTIL THE STRUCTURE IS FULLY STABLE. 102.9. THE CONTRACTOR SHALL COORDINATE PLACEMENT OF ALL EMBEDDED STEEL PLATES, ANCHOR BOLTS, AND SLEEVES WITH CONCRETE WORK TO ENSURE ACCURATE PLACEMENT. 102.10. GROUT BENEATH BASE PLATES SHALL BE NON -SHRINK AND INSTALLED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. 102.11. FIREPROOFING AND COATING SYSTEMS ARE NOT INCLUDED IN THE STRUCTURAL SCOPE AND SHALL BE PROVIDED AS REQUIRED BY OTHERS. MINIMUM CORROSION RESISTANCE FOR STRUCTURAL STEEL EXPOSED TO WEATHER SHALL BE AS FOLLOWS: 102.11.1. ALL STRUCTURAL STEEL FRAMING EXPOSED TO WEATHER SHALL BE PROTECTED WITH A CORROSION -RESISTANT COATING SYSTEM. UNO, EXPOSED STEEL SHALL BE HOT -DIPPED GALVANIZED OR PAINTED WITH AN APPROVED PRIMER AND FINISH COATING SUITABLE FOR EXTERIOR EXPOSURE. SURFACES SHALL BE PREPARED AND COATINGS SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS AND RECOMMENDATIONS. 103. DIMENSIONAL LUMBER 103.1. ALL SOFTWOOD LUMBER SHALL COMPLY WITH THE LATEST EDITION OF THE AMERICAN SOFTWOOD LUMBER STANDARD DOC PS 20, AS PUBLISHED BY THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY (NIST). 103.2. SAWN LUMBER SHALL BE IDENTIFIED BY A GRADE MARK BY AN ACCREDITED AGENCY PER DOC PS 20; APPROVED END -JOINTED LUMBER OF THE SAME SPECIES AND GRADE MAY BE USED INTERCHANGEABLY WITH SOLID -SAWN MEMBERS AND SHALL BE DESIGNATED "HRA" WHERE FIRE -RESISTANCE IS REQUIRED. 103.3. LUMBER SHALL BE SURFACED DRY (S-DRY) OR KILN -DRIED (KD) WITH A MAXIMUM MOISTURE CONTENT OF 19% AT TIME OF INSTALLATION. 103.4. LUMBER GRADE SHALL BE AS SPECIFIED IN THE GENERAL FRAMING NOTES. 103.5. LUMBER USED IN EXTERIOR OR HIGH -MOISTURE CONDITIONS, AND ANY WOOD LOCATED WITHIN 6 INCHES OF FINISHED GRADE, SHALL BE PRESERVATIVE -TREATED AND LABELED ACCORDINGLY, IN ACCORDANCE WITH AWPA U1 AND AWPA M4 STANDARDS. 103.6. ALL LUMBER SHALL BE STORED PER NOTE 101.1. 104. ENGINEERED LUMBER 104.1. ALL ENGINEERED WOOD PRODUCTS SHALL BE MANUFACTURED IN ACCORDANCE WITH APPLICABLE STANDARDS, INCLUDING: 104.1.1. ASTM D5456 FOR PSL AND LSL 104.1.2. APA EWS FOR LVL 104.1.3. APA PRR 410 FOR RIM BOARD 104.1.4. ASTM D5055 FOR PREFABRICATED WOOD I -JOISTS 104.2. PRODUCTS SHALL BEAR A LEGIBLE STAMP OR LABEL IDENTIFYING THE MANUFACTURER, GRADE OR SERIES, EVALUATION REPORT NUMBER, AND CERTIFICATION AGENCY MARK. 104.3. MEMBERS SHALL BE SIZED AND INSTALLED PER STRUCTURAL DRAWINGS AND MANUFACTURER'S PUBLISHED LITERATURE. 104.4. FIELD MODIFICATIONS, INCLUDING BUT NOT LIMITED TO CUTTING, NOTCHING, DRILLING, OR PENETRATING OF ENGINEERED WOOD MEMBERS, ARE NOT PERMITTED UNLESS EXPLICITLY SHOWN ON THE APPROVED DRAWINGS R AUTHORIZED BY PRI R WRITTEN APPROVAL FROM THE STRUCTURAL 0 GS 00 0 0 S UCTU ENGINEER OF RECORD. 104.4.1. FOR PREFABRICATED I -JOISTS, WEB HOLES AND OPENINGS ARE PERMITTED ONLY WHERE SIZED, LOCATED, AND REINFORCED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 104.5. RIM BOARD SHALL CONFORM TO APA PRR 410 AND BE CLEARLY LABELED. ACCEPTABLE MATERIALS INCLUDE LVL, OR LSL AS PERMITTED UNDER PRR 410. RIM BOARD SHALL BE INSTALLED TIGHT TO ADJACENT FRAMING AND FASTENED PER PRR 410. DO NOT NOTCH OR DRILL UNLESS SPECIFICALLY ALLOWED BY THE MANUFACTURER OR DESIGN DOCUMENTS. 104.6. PREFABRICATED I -JOISTS SHALL CONFORM TO ASTM D5055 AND BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S SPAN TABLES AND INSTALLATION INSTRUCTIONS. 104.7. I -JOISTS SHALL BEAR FULLY ON APPROVED SUPPORTS AND BE LATERALLY BRACED AS REQUIRED. 104.7.1. JOIST HANGERS AND BLOCKING PANELS SHALL BE COMPATIBLE WITH I -JOIST SPECIFICATIONS AND FASTENED PER MANUFACTURER REQUIREMENTS. 104.8. ENGINEERED WOOD PRODUCTS SHALL BE STORED AND PROTECTED IN ACCORDANCE WITH NOTE 101.1. ENGINEERED WOOD PRODUCTS ARE PARTICULARLY SENSITIVE TO MOISTURE EXPOSURE AND SHALL NOT BE INSTALLED IF SWELLING, DELAMINATI N R THERM I T RE -RELATED DAMAGE I OBSERVED. S S G 0 0 0 OS U G SO S 104.9. THE CONTRACTOR SHALL VERIFY SPANS, LOADS, BEARING, AND FIT -UP PRIOR TO INSTALLATION. DISCREPANCIES SHALL BE COORDINATED WITH THE FOR PER NOTE 100.2. 105. GLUE -LAMINATED TIMBER (GLULAM) 105.1. GLULAM MEMBERS SHALL BE MANUFACTURED AND IDENTIFIED AS REQUIRED IN ANSI A190.1, ANSI 117, AND ASTM D3737. MEMBERS SHALL BEAR THE MANUFACTURER'S STAMP SHOWING GRADE, SPECIES, AND CERTIFICATION AGENCY. 105.2. MOISTURE CONTENT SHALL BE AS FOLLOWS: 105.2.1. KILN -DRIED GLULAM (TYPICALLY 12% f3% MOISTURE CONTENT) SHALL BE USED FOR INTERIOR OR PROTECTED EXTERIOR ENVIRONMENTS WHERE EXPOSURE TO MOISTURE IS MINIMAL. 105.2.2. WOLMANIZED OR TREATED GLULAM SHALL BE USED FOR EXTERIOR, EXPOSED, OR HIGH -MOISTURE ENVIRONMENTS. THESE MAY INCLUDE GLULAM FABRICATED FROM HIGHER -MOISTURE OR GREEN LUMBER AND/OR PRESSURE -PRESERVATIVE -TREATED PRODUCTS. THESE MEMBERS SHALL BE PROTECTED FROM PROLONGED WETTING AND INSTALLED WITH APPROPRIATE DETAILING (FLASHING, SEALING, ETC.). 105.3. GLULAM SHALL MATCH THE SIZES, SHAPES (STRAIGHT, CURVED, TAPERED), AND CAMBER AS SHOWN ON STRUCTURAL DRAWINGS. 105.4. GLULAM MEMBERS SHALL BE STORED AND PROTECTED IN ACCORDANCE WITH NOTE 101.1. GLULAM MEMBERS SHALL BE PROTECTED FROM DIRECT SUN AND WEATHER EXPOSURE TO PREVENT CHECKING, SURFACE WEATHERING, AND FINISH DEGRADATION. END GRAIN SHALL BE SEALED OR WRAPPED TO MINIMIZE DIFFERENTIAL MOISTURE ABSORPTION. 105.5. FIELD MODIFICATIONS, INCLUDING BUT NOT LIMITED TO CUTTING, NOTCHING, DRILLING, OR PENETRATING OF GLULAM MEMBERS, ARE NOT PERMITTED UNLESS EXPLICITLY SHOWN ON THE APPROVED DRAWINGS OR AUTHORIZED BY PRIOR WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER OF RECORD. 105.6. ALL FIELD CUTS, NOTCHES, AND FASTENER PENETRATIONS IN TREATED OR EXTERIOR -USE GLULAM SHALL BE SEALED WITH AN APPROVED PRESERVATIVE TREATMENT. 105.7. TYPICAL GLULAM GRADES SHALL BE AS FOLLOWS: 105.7.1. 24F-V4 DF FOR SINGLE SPANS 105.7.2. 24F-V8 DF FOR CANTILEVER BEAM OR CONTINUOUS MULTI -SPAN BEAMS 106. PRE-ENGINEERED WOOD OPEN WEB TRUSSES 106.1. WOOD TRUSSES SHALL BE DESIGNED BY A LICENSED TRUSS MANUFACTURER IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICE AND ANSI/TPI 1 STANDARDS. 106.2. THE TRUSS DESIGN DRAWINGS SHALL BE PREPARED AND SEALED BY A REGISTERED DESIGN PROFESSIONAL. 106.3. THE TRUSS DESIGNER SHALL REVIEW THE ARCHITECTURAL AND STRUCTURAL DRAWINGS TO VERIFY PROPER APPLICATION OF ALL LOADS AS SPECIFIED IN SECTIONS 116 AND 117 OF THESE NOTES, TABULATED DEAD LOADS FROM SECTION 116 SHALL BE APPLIED AS UNIFORMLY DISTRIBUTED LOADS OVER THE TOP CHORD WITH AN ADDITIONAL 5 PSF DEAD LOAD APPLIED TO THE BOTTOM CHORD. 106.4. THE TRUSS DESIGNER SHALL ADHERE TO THE MAXIMUM DEFLECTION LIMITS SPECIFIED BY CODE AND PROJECT REQUIREMENTS AS SET FORTH IN THE SECTION 118 OF THESE NOTES, AS APPROPRIATE FOR THE APPLICATION OF THE TRUSSES. DEFLECTION CRITERIA SHALL ACCOUNT FOR THE INTENDED USE OF THE SPACE AND FINISHES ATTACHED TO THE TRUSS SYSTEM. 106.5. ALL TRUSS CONNECTIONS/HANGERS SHALL BE PER TRUSS DESIGN DRAWINGS. 106.6. TRUSSES SHALL NOT BE SPACED FURTHER APART THAN: 106.6.1. ROOF TRUSSES: 24" O.C. 106.6.2. FLOOR TRUSSES: 16" O.C. 106.7. TRUSS DESIGN DRAWINGS SHALL BE PROVIDED TO THE ENGINEER OF RECORD AND APPROVED PRIOR TO FABRICATION. TRUSS DESIGN DRAWINGS SHALL BE PROVIDED WITH THE SHIPMENT OF TRUSSES DELIVERED TO THE JOB SITE. TRUSS DESIGN DRAWINGS SHALL INCLUDE, AT A MINIMUM, THE FOLLOWING INFORMATION: 106.7.1. SLOPE, DEPTH, SPAN AND SPACING. 106.7.2. LOCATION OF ALL JOINTS. 106.7.3. REQUIRED BEARING WIDTHS. 106.7.4. DESIGN LOADS AS APPLICABLE. 106.7.4.1. TOP CHORD LIVE LOAD (AS DETERMINED FROM SECTION R301.6). 106.7.4.2. TOP CHORD DEAD LOAD. 106.7.4.3. BOTTOM CHORD LIVE LOAD. 106.7.4.4. BOTTOM CHORD DEAD LOAD. 106.7.4.5. CONCENTRATED LOADS AND THEIR POINTS OF APPLICATION. 106.7.4.6. CONTROLLING WIND AND EARTHQUAKE LOADS. 106.7.5. ADJUSTMENTS TO LUMBER AND JOINT CONNECTOR DESIGN VALUES FOR CONDITIONS OF USE. 106.7.6. EACH REACTION FORCE AND DIRECTION. 106.7.7. JOINT CONNECTOR TYPE AND DESCRIPTION SUCH AS SIZE, THICKNESS OR GAUGE AND THE DIMENSIONED LOCATION OF EACH JOINT CONNECTOR EXCEPT WHERE SYMMETRICALLY LOCATED RELATIVE TO THE JOINT INTERFACE. 106.7.8. LUMBER SIZE, SPECIES AND GRADE FOR EACH MEMBER. 106.7.9. CONNECTION REQUIREMENTS FOR: 106.7.9.1. TRUSS TO GIRDER TRUSS. 106.7.9.2. TRUSS TO BEAM. 106.7.9.3. TRUSS PLY TO PLY. 106.7.9.4. FIELD SPLICES, 106.7.10. CALCULATED DEFLECTION RATIO OR MAXIMUM DEFLECTION FOR LIVE AND TOTAL LOAD, OR APPLICABLE LOAD COMBINATION PRODUCING MAXIMUM DEFLECTION. 106.7.11. MAXIMUM AXIAL COMPRESSION FORCES IN THE TRUSS MEMBERS TO ENABLE THE BUILDING DESIGNER TO DESIGN THE SIZE, CONNECTIONS AND ANCHORAGE OF THE PERMANENT CONTINUOUS LATERAL BRACING. FORCES SHALL BE SHOWN ON THE TRUSS DESIGN DRAWING OR ON SUPPLEMENTAL DOCUMENTS. 106.7.12. REQUIRED PERMANENT TRUSS MEMBER BRACING LOCATION. 106.8. FOR VAULTED OR CATHEDRAL CEILING APPLICATIONS WITH SCISSOR TRUSSES: 106.8.1. TOP AND BOTTOM CHORD SLOPES MUST MATCH ARCHITECTURAL SECTION. 106.8.2. SCISSOR TRUSSES MUST BE DESIGNED FOR AN ENHANCED DEFLECTION ASSET FORTH IN THE SECTION 118 TO REDUCE THE POTENTIAL FOR CEILING CRACKS AND OUTWARD THRUST AT WALLS. 106.8.3. VERIFY HEEL HEIGHT TO ENSURE PROPER INSULATION AND VENTILATION CLEARANCE. 106.9. ROOF TRUSSES SUPPORTING MECHANICAL EQUIPMENT SHALL BE DESIGNED TO ACCOMMODATE ALL CONCENTRATED, DEAD, AND VIBRATION LOADS IMPOSED BY HVAC UNITS OR OTHER EQUIPMENT LOCATED WITHIN OR ABOVE THE TRUSS SYSTEM. IN THE AREA DESIGNATED AS THE MECHANICAL EQUIPMENT ZONE PER PLAN PER ARCHITECTURAL OR STRUCTURAL DRAWINGS, THE TRUSS DESIGNER SHALL ACCOUNT FOR AN ADDITIONAL LIVE LOAD EQUAL TO THE ATTIC LOAD WITH LIMITED STORAGE APPLIED ALONG THE BOTTOM CHORD OF THE AFFECTED TRUSSES. 106.9.1. FOR MECHANICAL HVAC EQUIPMENT THAT IS TO BE SUSPENDED FROM THE TOP CHORD OF THE TRUSS, THE TRUSS DESIGNER SHALL COORDINATE WITH THE BUILDER REGARDING THE WEIGHT OF THE EQUIPMENT AND THE EXACT LOCATION OF ALL SUPPORT POINTS, TO ENSURE PROPER DESIGN AND LOAD TRANSFER. REINFORCEMENT OR SUPPLEMENTAL MEMBERS SHALL BE PROVIDED AS REQUIRED 106.9.2. NO MECHANICAL EQUIPMENT SHALL BE PLACED ON OR WITHIN ATTIC TRUSSES WITHOUT PRIOR DESIGN APPROVAL. 107. WOOD SHRINKAGE 107.1. DUE TO CROSS -GRAIN SHRINKAGE IN WOOD FRAMING, THIS BUILDING IS EXPECTED TO EXPERIENCE VERTICAL SETTLEMENT OF APPROXIMATELY 3/8 INCH PER STORY. ALL PLUMBING, MECHANICAL, AND ELECTRICAL SYSTEMS SHALL BE DESIGNED WITH FLEXIBLE JOINTS, SLIP COUPLINGS, OR OTHER APPROPRIATE MEANS TO ACCOMMODATE THIS ANTICIPATED MOVEMENT. INTERIOR AND EXTERIOR SHEATHING, FINISHES, AND TRIM SHALL BE DETAILED AND INSTALLED TO PREVENT DAMAGE FROM DIFFERENTIAL SETTLEMENT. SHRINKAGE IS EXPECTED TO OCCUR PRIMARILY IN THE DEPTH OF FLOOR FRAMING AND PLATES, NOT IN THE LENGTH OF VERTICAL WALL STUDS. 108. WOOD STRUCTURAL PANELS 108.1. WOOD STRUCTURAL PANELS SHALL COMPLY WITH APPLICABLE APA PERFORMANCE STANDARDS: 108.1.1. PRP-108 FOR STRUCTURAL PLYWOOD, MANUFACTURED IN ACCORDANCE WITH U.S. DOC PS 1 108.1.2. PRP-210 FOR OSB AND OTHER NON -VENEER STRUCTURAL PANELS, MANUFACTURED IN ACCORDANCE WITH U.S. DOC PS 2 108.2. ALL PANELS SHALL BEAR A VALID APA GRADE STAMP (OR EQUIVALENT THIRD -PARTY CERTIFIED AGENCY) INDICATING PANEL TYPE, THICKNESS, SPAN RATING, EXPOSURE CLASSIFICATION, AND MILL IDENTIFICATION. 108.3. PANELS SHALL BE RATED EXPOSURE 1 (FOR PROTECTED CONSTRUCTION) OR EXTERIOR (FOR FULLY WEATHER -EXPOSED USE), AS APPROPRIATE TO PROJECT CONDITIONS. INTERIOR -ONLY PANELS ARE NOT PERMITTED IN STRUCTURAL APPLICATIONS. 108.3.1. WHERE MARINE GRADE PLYWOOD IS SPECIFIED, IT SHALL COMPLY WITH U.S. DOC PS 1 REQUIREMENTS FOR MARINE GRADE CLASSIFICATION, BEARING AN APA STAMP DESIGNATING "MARINE". 108.4. ALL PANELS SHALL BE INSTALLED WITH FACE GRAIN PERPENDICULAR TO SUPPORTS. 108.5. PANELS SHALL BE SPACED WITH 1/8" GAPS AT EDGES AND ENDS TO ALLOW FOR EXPANSION, UNLESS OTHERWISE NOTED. 108.6. FASTENING SHALL COMPLY WITH IBC TABLE 2304.10.1 OR IRC TABLE R602.3(1), GENERAL FRAMING NOTES, AND ANY APPLICABLE STRUCTURAL DETAILS OR SHEAR WALL SCHEDULES. NAILS SHALL BE DRIVEN FLUSH AND SHALL NOT FRACTURE THE SURFACE OF SHEATHING. 108.7. FASTENERS IN CONTACT WITH TREATED WOOD SHEATHING OR USED IN EXTERIOR APPLICATIONS SHALL BE HOT -DIP GALVANIZED ASTM A153 OR STAINLESS STEEL. 108.8. WHERE APPLICABLE, USE APA-APPROVED CONSTRUCTION ADHESIVES IN COMBINATION WITH MECHANICAL FASTENERS FOR FLOOR SHEATHING SYSTEMS. 108.9. FIELD MODIFICATIONS, INCLUDING BUT NOT LIMITED TO CUTTING, NOTCHING, DRILLING, OR PENETRATING OF WOOD STRUCTURAL PANELS, ARE NOT PERMITTED UNLESS EXPLICITLY SHOWN ON THE APPROVED DRAWINGS OR AUTHORIZED BY PRIOR WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER OF RECORD. 109. FIRE RETARDANT -TREATED (FRT) WOOD 109.1. WHERE FIRE -RETARDANT -TREATED (FRT) LUMBER OR PLYWOOD IS SPECIFIED OR REQUIRED BY CODE, IT SHALL BE PRESSURE -IMPREGNATED WITH FIRE -RETARDANT CHEMICALS IN ACCORDANCE WITH AWPA C20 (LUMBER) OR C27 (PLYWOOD). FRT WOOD SHALL BE CLEARLY LABELED AND SHALL NOT BE USED INTERCHANGEABLY WITH UNTREATED MEMBERS. ALL FASTENERS AND CONNECTORS IN CONTACT WITH FRT WOOD SHALL COMPLY WITH THE REQUIREMENTS OF NOTES 110.3 AND 111.3 RESPECTIVELY. 110. MECHANICAL FASTENERS T 110.1 FASTENERS SHALL CONFORM TO APPLICABLE STANDARDS. INSTALLATION SHALL FOLLOW NDS REQUIREMENTS AS WELL AS FASTENER AND CONNECTOR MANUFACTURER'S REQUIREMENTS. FASTENERS SHALL BE COMPATIBLE WITH ALL HARDWARE PER MANUFACTURER SPECIFICATIONS. 110.2. NAILING SHALL BE IN ACCORDANCE WITH IBC TABLE 2304.10.1, IRC TABLE R602.3(1), THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION (NDS), OR AS SPECIFIED IN THE TYPICAL NAILING SCHEDULE OF THE GENERAL FRAMING NOTES, UNO ON THE DRAWINGS OR SPECIFIC DETAILS. 110.3. STANDARD FASTENERS SHALL BE CARBON STEEL UNLESS OTHERWISE NOTED. FASTENER CORROSION PROTECTION SHALL COMPLY WITH THE FOLLOWING REQUIREMENTS: 110.3.1. ALL MECHANICAL FASTENERS (NAILS, BOLTS, LAG SCREWS, NUTS, AND WASHERS) IN CONTACT WITH PRESSURE -TREATED, FIRE -RETARDANT -TREATED (FRT), OR EXTERIOR -EXPOSED WOOD SHALL BE HOT -DIP GALVANIZED, STAINLESS STEEL, OR MANUFACTURER APPROVED EQUIVALENT COATED FASTENERS, IN ACCORDANCE WITH THE FOLLOWING APPLICABLE STANDARDS: 110.3.1.1. NAILS: ASTM A153 CLASS D 110.3.1.2. BOLTS, LAG SCREWS, NUTS, AND WASHERS: ASTM A153 CLASS C OR ASTM F2329. 110.3.1.3. STAINLESS STEEL: TYPE 304 OR 316. 110.3.1.3.1. USE TYPE 304 OR 316 STAINLESS STEEL OR HDG FASTENERS IN EXPOSED, COASTAL, HIGH -MOISTURE, OR CHEMICALLY TREATED ENVIRONMENTS. 110.3.1.3.2. TYPE 316 STAINLESS STEEL IS REQUIRED WITHIN 300 FEET OF A SALTWATER SHORELINE OR WHERE EXPOSURE TO SALT AIR OR SALTWATER IS ANTICIPATED. 110.3.2. ELECTROPLATED OR MECHANICALLY GALVANIZED FASTENERS ARE NOT PERMITTED FOR USE WITH PRESERVATIVE -TREATED OR FIRE -RETARDANT -TREATED (FRT) WOOD UNLESS SPECIFICALLY APPROVED IN WRITING BY THE EOR. 110.3.3. FASTENER FINISH AND CORROSION -RESISTANCE LEVEL SHALL BE COMPATIBLE WITH AND MATCHED TO THE CONNECTOR OR HARDWARE IT IS USED WITH. REFERENCE NOTE 111.3 FOR ADDITIONAL INFORMATION. 110.4. NAILS SHALL BE SMOOTH - COMMON, OR BOX NAILS AS SPECIFIED, AND MEET THE REQUIREMENTS OF ASTM F1667. PNEUMATICALLY DRIVEN NAILS MUST MATCH REQUIRED DIAMETER AND PENETRATION. NAILS USED FOR FRAMING AND SHEATHING CONNECTIONS SHALL HAVE A MINIMUM AVERAGE BENDING YIELD STRENGTH AS SHOWN: 110.4.1. 8OKSI FOR SHANK DIAMETER OF 0.192 INCH 110.4.2. 9OKSI FOR SHANK DIAMETER LARGER THAN 0.142 INCH BUT NOT LARGER 0.177 INCH 110.4.3. 10OKSI FOR SHANK DIAMETERS OF 0.142 INCH OR LESS 110.5. SCREWS: MUST BE STRUCTURAL -RATED (E.G., RSS, SDS, SDWS, OR OTHERS AS SPECIFIED). SCREWS NOT SPECIFICALLY RATED FOR STRUCTURAL USE ARE NOT PERMITTED FOR STRUCTURAL APPLICATIONS. SCREWS SHALL NOTE BE USED IN LIEU OF NAILS UNLESS SPECIFICALLY CALLED OUT ON THE PLANS, NOTES, DETAILS, OR AS REQUIRED BY THE MECHANICAL CONNECTOR MANUFACTURER. 110.6. BOLTS: SHALL MEET ASTM F3125 GRADE A325 OR A490 AND INCLUDE WASHERS UNDER ALL NUTS AND HEADS BEARING AGAINST WOOD. 110.7. LAG SCREWS: SHALL BE PROPERLY PREDRILLED UNLESS SELF -DRILLING TYPES ARE USED AND SHALL MEET CORROSION REQUIREMENTS AS ABOVE. 110.8. AVOID COMBINATIONS OF DISSIMILAR METALS THAT MAY CAUSE GALVANIC CORROSION. INCLUDING ALUMINUM IN CONTACT WITH STEEL OR COPPER, OR MIXING OF STAINLESS STEEL AND GALVANIZED COMPONENTS, WHERE DISSIMILAR METALS CANNOT BE AVOIDED, AN APPROVED ISOLATION BARRIER OR COATING SHALL BE PROVIDED. SEE NOTES 110.3.3 AND 111.3.4 FOR SPECIFIC FASTENER AND CONNECTOR COMPATIBILITY REQUIREMENTS. 110.9. FASTENERS SHALL BE INSTALLED TO FULL REQUIRED DEPTH AND SEATED SNUGLY WITHOUT OVERDRIVING. 110.10. IMPROPERLY DRIVEN OR MISALIGNED FASTENERS SHALL BE REMOVED AND REPLACED. 110.11. MAINTAIN PROPER EDGE DISTANCES, END DISTANCES, AND SPACING AS SPECIFIED IN THE NDS AND PROJECT DRAWINGS. 110.12. SUBSTITUTIONS, ALTERATIONS IN FASTENER TYPE, OR SPACING SHALL NOT BE MADE WITHOUT WRITTEN APPROVAL FROM THE EOR. 111. MECHANICAL CONNECTORS 111.1. ALL CONNECTORS (E.G., JOIST HANGERS, STRAPS, POST BASES, HOLDOWNS, TIE PLATES, FRAMING ANGLES) SHALL BE MANUFACTURED IN ACCORDANCE WITH APPLICABLE STANDARDS INCLUDING ICC-ES AC13, AC233, OR OTHER RECOGNIZED ACCEPTANCE CRITERIA, AND INSTALLED PER BUILDING CODE AND MANUFACTURER'S PUBLISHED INSTALLATION REQUIREMENTS. 111.2. CONNECTORS SHALL BE PRODUCTS OF RECOGNIZED STRUCTURAL HARDWARE MANUFACTURERS SUCH AS SIMPSON STRONG -TIE, USP STRUCTURAL CONNECTORS, OR APPROVED EQUIVALENT. ALL SUBSTITUTIONS MUST BE PRE -APPROVED IN WRITING BY THE EOR. 111.3. CONNECTORS IN CONTACT WITH PRESSURE -TREATED, FIRE -RETARDANT -TREATED (FRT), OR EXTERIOR -EXPOSED WOOD SHALL BE: 111.3.1. HOT -DIP GALVANIZED PER ASTM A653 G185 OR ASTM A123 AS APPLICABLE 111.3.2. STAINLESS STEEL TYPE 304 OR 316, AS APPROPRIATE 111.3.3. ELECTRO-GALVANIZED (G60) OR PAINTED CONNECTORS ARE NOT ACCEPTABLE IN TREATED OR EXTERIOR APPLICATIONS 111.3.4. CONNECTORS AND THEIR ASSOCIATED FASTENERS SHALL BE OF COMPATIBLE AND MATCHING CORROSION -RESISTANCE LEVELS. STAINLESS STEEL CONNECTORS SHALL BE FASTENED WITH STAINLESS STEEL FASTENERS, AND HOT -DIP GALVANIZED CONNECTORS SHALL BE FASTENED WITH HOT -DIP GALVANIZED FASTENERS OF EQUIVALENT OR GREATER ZINC COATING WEIGHT. MIXING OF DISSIMILAR METAL FINISHES BETWEEN CONNECTORS AND FASTENERS IS NOT PERMITTED. 111.4. USE ONLY MANUFACTURER -SPECIFIED FASTENERS (TYPE, SIZE, NUMBER, AND SPACING) WITH EACH CONNECTOR. SIZE AND QUANTITY OF FASTENERS SHALL BE SELECTED TO ACHIEVE MAXIMUM SPECIFIED LOAD FOR THE CONNECTOR. 111.5. SUBSTITUTION OF NAILS WITH SCREWS, OR VICE VERSA, OR SUBSTITUTION OF NAILS FOR SMALLER SIZE OR DIAMETER IS NOT PERMITTED UNLESS APPROVED IN WRITING BY THE FOR OR NOTED IN THE APPROVED DRAWINGS. 111.6. ALL CONNECTORS SHALL BE INSTALLED FLUSH WITH THE WOOD SURFACE AND FULLY FASTENED USING THE SPECIFIED PATTERN AND NUMBER OF FASTENERS. OVERDRIVEN OR IMPROPERLY ALIGNED CONNECTORS MUST BE REMOVED AND REPLACED. 111.7. FIELD WELDING, CUTTING, OR BENDING OF CONNECTORS IS NOT PERMITTED UNLESS SPECIFICALLY DESIGNED FOR SUCH MODIFICATION. 111.8. WHERE CONNECTORS ATTACH TO CONCRETE OR MASONRY, USE ANCHORS (E.G., EXPANSION BOLTS, EPDXY -SET ANCHORS, OR CONCRETE BOLTS) AS SPECIFIED ON DRAWINGS AND RATED FOR THE INTENDED LOAD. 111.9. CONTRACTOR SHALL VERIFY THAT ALL INSTALLED CONNECTORS ARE OF THE CORRECT TYPE AND ORIENTATION, AND THAT ALL FASTENERS ARE IN PLACE PRIOR TO CONCEALMENT OR COVERING. 112. POST -INSTALLED ANCHORS 112.1. POST -INSTALLED MECHANICAL ANCHORS (EXPANSION, SCREW -TYPE, OR UNDERCUT) SHALL BE ICC-ES LISTED AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS AND THE APPLICABLE ICC-ES EVALUATION REPORT. ANCHORS SHALL NOT BE INSTALLED IN CRACKED CONCRETE UNLESS SPECIFICALLY RATED AND ICC-ES LISTED FOR SUCH USE. 112.2. ANCHOR TYPE, SIZE, EMBEDMENT DEPTH, AND EDGE AND SPACING DISTANCES SHALL BE AS SHOWN ON THE STRUCTURAL DRAWINGS AND SHALL COMPLY WITH ACI 318 AND THE MANUFACTURER'S PUBLISHED REQUIREMENTS. SUBSTITUTIONS SHALL NOT BE MADE WITHOUT WRITTEN APPROVAL FROM THE EOR. 113. EPDXY ADHESIVES 113.1. EPDXY ADHESIVES SHALL BE TWO -COMPONENT, HIGH -STRENGTH, STRUCTURAL EPDXY BONDING AGENTS SUITABLE FOR ANCHORING APPLICATIONS IN CRACKED AND UNCRACKED CONCRETE. 113.2. EPDXY ADHESIVE SHALL MEET OR EXCEED THE PERFORMANCE STANDARDS OF THE FOLLOWING PRODUCT: 113.2.1. SIMPSON STRONG -TIE® SET-3G'" - HIGH -STRENGTH, TWO -COMPONENT EPDXY ADHESIVE OR APPROVED EQUIVALENT. 113.2.2. MUST BE ICC-ES LISTED (E.G., ESR-4057 OR CURRENT ICC-ES LISTED EQUIVALENT), SUITABLE FOR SEISMIC, WIND, AND SUSTAINED LOADS. 113.3. MIN INSTALLATION REQUIREMENTS SHALL BE AS FOLLOWS: 113.3.1. PRIOR TO EPDXY PLACEMENT, HOLES SHALL BE DRILLED AND CLEANED PER MANUFACTURER'S INSTRUCTIONS. 113.3.2. EPDXY SHALL BE DISPENSED USING A STATIC MIXING NOZZLE PROVIDED BY THE MANUFACTURER. 113.3.3. ANCHOR ELEMENTS SHALL BE INSERTED WHILE ROTATING TO ENSURE COMPLETE WETTING AND TO AVOID VOIDS. 113.3.4. ANCHORS SHALL REMAIN UNDISTURBED UNTIL THE ADHESIVE HAS FULLY CURED. REFER TO MANUFACTURER'S CURE TIMES BASED ON AMBIENT AND SUBSTRATE TEMPERATURES. 113.4. QUALITY CONTROL 113.4.1. EPDXY INSTALLATION SHALL BE PERFORMED BY QUALIFIED PERSONNEL. 113.4.2. THE CONTRACTOR SHALL MAINTAIN RECORDS OF BATCH NUMBERS, INSTALLATION TEMPERATURES, AND CURE TIMES. 113.4.3. FIELD PULL TESTING MAY BE REQUIRED AT THE DISCRETION OF THE EOR. 113.4.4. EPDXY ADHESIVES SHALL BE STORED AND HANDLED IN ACCORDANCE WITH NOTE 101.1 AND THE MANUFACTURER'S PUBLISHED REQUIREMENTS. EPDXY SHALL BE STORED WITHIN THE TEMPERATURE RANGE SPECIFIED BY THE MANUFACTURER. EXPOSURE TO EXTREME HEAT, COLD, OR DIRECT SUNLIGHT SHALL BE AVOIDED. 113A.5. EPDXY ADHESIVES SHALL NOT BE USED BEYOND THE MANUFACTURER'S STATED SHELF LIFE OR EXPIRATION DATE. EXPIRED MATERIAL SHALL BE REMOVED FROM THE JOBSITE AND PROPERLY DISPOSED OF. 114. WALL COVERING 114.1. EXTERIOR WALL COVERING SHALL BE DESIGNED BY OTHERS TO PROVIDE A WEATHER -RESISTANT ENVELOPE INCLUDING FLASHING AS REQUIRED. THE WALL ASSEMBLY SHALL INCORPORATE A WATER -RESISTIVE BARRIER BEHIND THE EXTERIOR CLADDING AND A MEANS OF DRAINING WATER THAT PENETRATES THE CLADDING TO THE EXTERIOR. 114.2. WOOD SIDING, PANEL SIDING, SHAKES, AND SHINGLES SHALL BE INSTALLED PER APPLICABLE CODE AND MANUFACTURER REQUIREMENTS, WITH REQUIRED SHEATHING OR FURRING, PROPER NAILING, WATER -RESISTIVE BARRIER, AND ALL JOINTS LOCATED OVER FRAMING AND LAPPED OR FLASHED, 114.3. PLASTER OR STUCCO: COMPLY WITH ASTM C926, C1063, AND APPLICABLE CODES. USE APPROVED CEMENT TYPES. APPLY THREE -COAT OVER LATH, TWO -COAT OVER MASONRY/CONCRETE. STOP AT WEEP SCREED FOR SLAB -ON -GRADE WOOD CONSTRUCTION. 114.4. ANCHORED VENEER (STONE/ MASONRY): INSTALL PER APPLICABLE CODE AND MANUFACTURER REQUIREMENTS. MAX THICKNESS ALLOWED: 3 5/8", FOR THICKER VENEER CONTRACTOR SHALL NOTIFY THE FOR IN WRITING PRIOR TO CONSTRUCTION COMMENCEMENT FOR VERIFICATION OF SUPPORT REQUIREMENTS. PROVIDE MOVEMENT JOINTS AT TRANSITIONS BETWEEN MASONRY SUPPORTED BY THE FRAMING AND THE FOUNDATION. USE CORROSION -RESISTANT TIES SPACED MAX 16" O.C. EACH WAY AND WITHIN 12" OF LARGE OPENINGS. MORTAR: ASTM C270 TYPE N. 114.4.1. ADHERED MASONRY VENEER: COMPLY WITH APPLICABLE CODES AND TMS 402 602. MAINTAIN REQUIRED CLEARANCE ABOVE GRADE/PAVING. 115. ROOF COVERINGS 115.1. ALL ROOFING MATERIALS AND ASSEMBLIES SHALL COMPLY WITH THE APPLICABLE BUILDING CODE, MANUFACTURER'S INSTALLATION INSTRUCTIONS, APPLICABLE ASTM STANDARDS, AND APPROVED EVALUATION REPORTS (ICC-ES, UL, ETC). 115.2. ROOF COVERING TYPE (E.G., ASPHALT SHINGLES, METAL PANELS, TILE, TPO MEMBRANE) SHALL MATCH THE ARCHITECTURAL SPECIFICATIONS AND DETAILS, AND SHALL BE SUITABLE FOR THE INSTALLED SLOPE, AND MINIMUM SLOPE REQUIREMENTS SHALL BE MET PER CODE AND PRODUCT MANUFACTURER: 115.2.1. ASPHALT SHINGLES: MIN. 2:12 WITH DOUBLE UNDERLAYMENT; MIN. 4:12 WITH SINGLE UNDERLAYMENT 115.2.2. METAL PANELS: VARIES BY PROFILE AND SEAM TYPE 115.2.3. LOW -SLOPE SYSTEMS (E.G., TPO, EPDM): DESIGNED PER NRCA OR FM GUIDELINES 115.3. ALL MATERIALS SHALL BE CLASS A FIRE -RATED WHERE REQUIRED BY CODE OR PROJECT SPECIFICATIONS. 115.4. ROOF ASSEMBLIES SHALL PROVIDE POSITIVE DRAINAGE. FLAT ROOFS SHALL MAINTAIN A MINIMUM SLOPE OF 1/4" PER FOOT TOWARD DRAINS OR SCUPPERS UNLESS OTHERWISE DESIGNED AND DETAILED. 115.5. UNDERLAYMENT SHALL COMPLY WITH APPLICABLE STANDARDS (E.G., ASTM D226, D4869, D1970 FOR ICE BARRIER). 115.6. PROVIDE ICE AND WATER SHIELD, FLASHING AS REQ'D PER CODE AND MANUFACTURER GUIDELINES. 115.7. FASTENERS SHALL BE CORROSION -RESISTANT AND COMPATIBLE WITH THE ROOF COVERING AND DECK MATERIALS. FASTENING PATTERN AND TYPE SHALL FOLLOW MANUFACTURER WIND -RATED INSTALLATION INSTRUCTIONS OR CODE -REQUIRED UPLIFT RESISTANCE VALUES PER ASCE 7 AND LOCAL WIND ZONE REQUIREMENTS. 115.8. ALL ROOF PENETRATIONS (VENTS, FLUES, SKYLIGHTS, ETC.) SHALL BE PROPERLY FLASHED AND SEALED PER CODE AND MANUFACTURER DETAILS. STEP FLASHING, HEAD FLASHING, AND CONTINUOUS FLASHING AS SPECIFIED BY OTHERS SHALL BE INSTALLED AT ALL WALL -ROOF INTERSECTIONS. 115.9. ROOFING CONTRACTOR SHALL VERIFY SUBSTRATE CONDITION BEFORE INSTALLATION. DAMAGED OR IMPROPERLY INSTALLED COVERINGS SHALL BE REMOVED AND REPLACED. 115.10. SOLAR PANELS SHALL ONLY BE INSTALLED IN ROOF AREAS SPECIFICALLY DESIGNATED ON THE ROOF PLAN AS "SOLAR PANEL AREAS." INSTALLATION OF SOLAR PANELS OUTSIDE OF THESE DESIGNATED AREAS IS NOT PERMITTED WITHOUT PRIOR REVIEW AND WRITTEN APPROVAL BY THE ENGINEER OF RECORD (EOR). 116. DESIGN WEIGHTS OF ASSEMBLIES (DEAD LOADS) 116.1. THE CONTRACTOR SHALL REVIEW THE FOLLOWING DESIGN WEIGHTS OF ASSEMBLIES TABLE PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. IF ANY MATERIALS INTENDED FOR USE ON THE PROJECT EXCEED THE SPECIFIED MAXIMUM WEIGHT CRITERIA, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND THE FOR IN WRITING PRIOR TO CONSTRUCTION AND ALLOW ADEQUATE TIME FOR ANY NECESSARY DESIGN MODIFICATIONS: 116.2. EXT WALLS: 116.2.1. EXT WALL W/SIDING... 12PSF 116.2.2. EXT WALL W/STUCC0... 15PSF 116.2.3. EXT WALL W/BRICK OR STONE VENEER ... 48PSF (40PSF MAX VENEER WT, 3 5/8" MAX VENEER THK) 116.3. INT WALLS: 116.3.1. INT WALLS W/GYP... 8PSF 116.3.2. INT WALLS WITH PLASTER ON ONE SIDE ... 14PSF 116.3.3. INT WALLS WITH PLASTER ON TWO SIDES...20PSF 116.4. ROOF: 116.4.1. RAFTERS W/SHINGLE OR METAL COVERING ... 12PSF 116.4.2. RAFTERS W/TILE COVERING ... 2OPSF (12PSF MAX TILE WEIGHT) 116.4.3. TRUSSES W/SHINGLE OR METAL COVERING ... 15PSF TOP CHORD, 5 PSF BOT CHORD 116.4.4. TRUSSES W/TILE COVERING ... 23PSF TOP CHORD, 5 PSF BOT CHORD 116.4.5. RAFTERS OR TRUSSES WITH PLASTER CEILING DIRECTLY APPLIED TO THE BOTTOM SHALL BE DESIGNED FOR ADDITIONAL 8PSF (APPLIED TO BOT CHORD FOR TRUSS ASSEMBLIES) 116.5. CEILING FRAMING 116.5.1. W/LIMITED STORAGE ... IOPSF 116.5.2. W/OUT STORAGE ... 5PSF 116.5.3, W/PLASTER FINISH ... 2OPSF 116.6. FLOOR FRAMING 116.6.1. W/HARDWOOD OR CARPET FINISHES ... 12PSF 116.6.2. W/THIN-SET CERAMIC TILE FINISHES ... 17PSF 116.6.3, W/STONE OR MARBLE TILE ON FULL MORTAR BED ... 41PSF 116.6.4. TRUSS FLOOR FRAMING SHALL HAVE ADDITIONAL 5PSF APPLIED TO THE BOTTOM CHORD. 116.6.5. FLOOR FRAMING W/PLASTER CEILING DIRECTLY APPLIED TO THE BOTTOM SHALL BE DESIGNED FOR ADDITIONAL 8PSF (APPLIED TO BOT CHORD FOR TRUSS ASSEMBLIES). 116.6.6. W/LIGHTWEIGHT CONCRETE TOPPING ... ADDT 1OPSF DEAD LOAD PER INCH OF LWC THICKNESS APPLIED TO THE TOP OF THE FLOOR ASSEMBLY. 116.6.7, W/NORMAL WEIGHT CONCRETE TOPPING ... ADDT 12.5PSF DEAD LOAD PER INCH OF NWC THICKNESS APPLIED TO THE TOP OF THE FLOOR ASSEMBLY. 116.7. ENGINEERED PLANS PREPARED BY LONGITUDE 120 ENGINEERING AND DESIGN ARE GENERALLY DESIGNED FOR SHINGLE OR METAL ROOF COVERINGS, INTERIOR GYPSUM BOARD FINISHES, AND CERAMIC TILE, CARPET, OR WOOD FLOOR COVERINGS. PROJECTS INCORPORATING TILE ROOFING, INTERIOR PLASTER FINISHES, AND/OR MARBLE OR STONE TILE ON FULL MORTAR BED WILL INCLUDE A SPECIFIC NOTE ON THE PLANS INDICATING THAT THE FRAMING HAS BEEN DESIGNED TO MEET MORE STRINGENT STRUCTURAL REQUIREMENTS ASSOCIATED WITH HEAVIER AND/OR MORE BRITTLE MATERIALS. IF NO SUCH NOTE IS PROVIDED ON THE PLANS, THE CONTRACTOR SHALL NOTIFY FOR UPON REVIEW OF THE PROJECT AND PRIOR THE COMMENCEMENT OF CONSTRUCTION TO ALLOW ADEQUATE TIME FOR ANY NECESSARY DESIGN MODIFICATIONS. 117. LIVE LOADS 117.1. DESIGN LIVE LOADS SHALL CONFORM TO THE APPLICABLE BUILDING CODE AND ASCE 7 UNLESS SPECIFICALLY NOTED ON THE STRUCTURAL DRAWINGS FOR ADDITIONAL REQUIREMENTS. THE FOLLOWING DESIGN LIVE LOADS SHALL BE USED FOR THE STRUCTURE AS APPLICABLE. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL REVIEW THESE VALUES AND NOTIFY THE FOR IMMEDIATELY IF THEY DO NOT CONFORM WITH THE INTENDED USE OF ANY SPACE. 117.1.1. ROOF ... 20PSF 117.1.2. CEILING WITH LIMITED STORAGE ... 20PSF (TYPICAL) 117.1.3. CEILING WITHOUT STORAGE ... 1OPSF (ONLY WHEN MEETS IRC NON STORAGE CRITERIA) 117.1.4. CEILING WITH STORAGE ACCESSIBLE BY FIXED STAIR OR FULL SIZE DOOR ... 3OPSF 117.1.5. FLOOR ... 4OPSF 117.1.6. GARAGE ... 4OPSF OR 3,OOOLBS OVER 4.5"X4.5" AREA (NON CONCURRENT) 117.1.7. BALCONY/DECK ... 4OPSF 117.1.8. RAILING ... 50PLF UNIFORM OR 200LBS (NON CONCURRENT). LOAD SHALL BE APPLIED IN THE DIRECTION PRODUCING THE MAXIMUM EFFECT, TYPICALLY HORIZONTALLY. 118. DEFLECTION LIMITS 118.1. DEFLECTION LIMITS SHALL BE LIMITED TO THE MOST STRINGENT CRITERIA THAT IS APPLICABLE FOR THE DESIGN. MAX DEFLECTION LIMITS BELOW ARE BASED ON TOTAL LOAD DEFLECTION UNLESS INDIVIDUALLY SPECIFIED BASED ON LIVE LOAD (LL) OR TOTAL LOAD (TOTAL). TOTAL LOAD DEFLECTION CRITERIA MUST ACCOUNT FOR ALL LOAD FOR THE PARTICULAR MEMBER INCLUDING BUT NOT LIMITED TO LIVE LOAD, DEAD LOAD, ROOF LOAD, SNOW LOAD, WIND LOAD, SEISMIC LOAD, AND ETC: 118.1.1. ROOF: 118.1.1.1. RAFTERS W/SLOPES GREATER THAN 3:12 W/SHINGLE OR METAL COVERING... L/180 118.1.1.2. RAFTERS W/ SLOPES 3:12 OR LESS W/SHINGLE, METAL, OR TPO COVERING... L/240 118.1.1.3. RAFTERS W/TILE COVERING ... L/240 118.1.1.4. RAFTERS W/GYP CEILING DIRECTLY ATTACHED... L/240 118.1.1.5. RAFTERS W/PLASTER CEILING DIRECTLY ATTACHED ... L/360 118.1.1.6. ROOF TRUSSES...L/360 (LL) L/240 (TOTAL) 118.1.1.7. ROOF SCISSOR TRUSSES ... L/600 118.1.2. CEILING 118.1.2.1. CEILING JOISTS .... L/240 118.1.2.2. CEILING JOISTS W/PLASTER CEILING...L/360 118.1.3. FLOORS 118.1.3.1. FLOORS W/FLEXIBLE COVERING ... L/480 (LL), L/240 (TOTAL) 118.1.3.2. FLOORS W/THINSET CERAMIC TILE ... L/480 (LL), L/360 (TOTAL) 118.1.3.3. FLOORS SUPPORTING STONE OR MARBLE TILE ON FULL MORTAR BED.... L/720 OR 7/32" MAX WHICHEVER IS MORE STRINGENT 118.1.4. FRAMING SUPPORTING MASONRY VENEER... L/600 118.1.5. HEADERS 118.1.5.1. HEADERS SHALL HAVE THE SAME DEFLECTION CRITERIA TO FLOORS SECTION ABOVE BASED ON THE TYPE OF MATERIAL/APPLICABLE FINISHES IT SUPPORTS 118.1.5.2. TYP HEADER ... L/480 (LL), L/360 (TOTAL) 118.1.5.3. HEADERS AT SLIDING DOORS ... L/600 118.1.6. WALLS 118.1.6.1. EXT STUDS W/FLEXIBLE COVERINGS ... H/180 118.1.6.2. EXT STUDS W/EXT BRICK VENEER ... H/240 118.1.6.3. EXT STUDS W/STUCCO... H/360 118.1.6.4. EXT STUDS W/INT FACE COVERED W/PLASTER... H/360 NO MATTER EXTERIOR COVERING 118.1.6.5. INT STUDS W/GYP... H/180 118.1.6.6. INT STUDS W/PLASTER... H/360 118.2. REF NOTE 116.7 REGARDING TILE ROOFING, PLASTER FINISHES, AND STONE/MARBLE TILE APPLICATIONS. 119. DIMENSIONS AND LENGTH 119.1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ELEVATIONS BEFORE STARTING WORK. ANY DISCREPANCIES BETWEEN THESE STRUCTURAL DRAWINGS AND ANY OTHER DRAWINGS SHALL BE REPORTED PER NOTE 100.2. 119.2. ALL DIMENSIONS SHOWN ON THIS PLAN ARE FOR REFERENCE ONLY. DIMENSIONS ARE DERIVED FROM THE ARCHITECTURAL DRAWINGS, WHICH SHALL BE CONSIDERED THE GOVERNING SOURCE FOR ALL MEASUREMENTS. WORKING DIMENSIONS OR MATERIAL TAKE OFF SHALL NOT BE SCALED FROM PLANS, SECTIONS, OR DETAILS ON THESE DRAWINGS. 120. DELEGATED DESIGN 120.1. WHERE THE STRUCTURAL DRAWINGS INDICATE ELEMENTS ARE TO BE DESIGNED BY OTHERS OR 'DELEGATED DESIGN,' THE CONTRACTOR SHALL RETAIN A LICENSED ENGINEER TO PREPARE AND SEAL DESIGN DOCUMENTS FOR THOSE ELEMENTS. DELEGATED DESIGN DOCUMENTS SHALL BE SUBMITTED TO THE FOR FOR REVIEW PRIOR TO FABRICATION OR INSTALLATION. REVIEW BY THE FOR IS FOR GENERAL CONFORMANCE WITH THE STRUCTURAL INTENT ONLY AND DOES NOT RELIEVE THE DELEGATED ENGINEER OF RESPONSIBILITY FOR THEIR DESIGN. 120.2. WHERE THE DELEGATED DESIGN INCORPORATES LOADS SHOWN ON THE STRUCTURAL DRAWINGS, THOSE LOADS SHALL BE CONSIDERED ASO (ALLOWABLE STRESS DESIGN) LEVEL. 121. SHOP DRAWINGS AND SUBMITTALS 121.1. REVIEW OF SUBMITTALS AND SHOP DRAWINGS IS FOR GENERAL CONFORMANCE WITH THE STRUCTURAL DRAWINGS AND PROJECT SPECIFICATIONS, NOT FOR DIMENSION CONTROL. THE ENGINEER SHALL BE ENTITLED TO RELY ON THE ACCURACY AND COMPLETENESS OF INFORMATION PROVIDED BY THE CONTRACTOR, THE ARCHITECT, OR OTHER THIRD PARTY. 121.2. ALL DISCREPANCIES BETWEEN SHOP DRAWINGS AND STRUCTURAL PLANS SHALL BE REPORTED IN WRITING TO THE FOR AT THE TIME OF SUBMITTAL. 121.3. AN ELECTRONICPY F H P DRAWINGS FOR THE FOLLOWING ELEMENT ARE REQUIRED T BE 3 CO O SHOP GS 0 S QU 0 SUBMITTED TO FOR FOR REVIEW AND APPROVAL PRIOR TO FABRICATION: 121.3.1. PRE -MANUFACTURED WOOD TRUSSES L 121.3.2. -LAMINATED TIMBER ELEMENT 3 GU S 121.3.3. STRUCTURAL AND MISCELLANEOUS STEEL 121.3.4. CONCRETE DESIGN MIX 121.3.5. EPDXY ADHESIVES 121.3.6. HELICAL PILES 122. ALTERNATES 122.1. ALTERNATE ASSEMBLIES AND MATERIALS MAY BE SUBMITTED FOR REVIEW; HOWEVER, ACCEPTANCE IS NOT GUARANTEED. THE ENGINEER RESERVES THE RIGHT TO REQUIRE COMPENSATION FOR TIME SPENT REVIEWING SUCH ALTERNATES. 123. INSPECTIONS/OBSERVATIONS 123.1. INSPECTIONS SHALL BE IN CONFORMANCE WITH THE PROVISIONS OF IBC SECTION 110 OR IRC SECTION R109. 123.2. INSPECTIONS ARE GENERALLY CONDUCTED BY QUALIFIED INSPECTORS REPRESENTING EITHER THE ENGINEER OR A THIRD PARTY TO VERIFY THAT MATERIALS INSTALLATION IS IN SUBSTANTIAL CONFORMANCE WITH THE STRUCTURAL PLANS AND SPECIFICATIONS, OR TO VERIFY ACTUAL FIELD CONDITIONS AS THE BASIS FOR FIELD CHANGES OR REPAIRS. INSPECTIONS ARE REPRESENTATIVE OF THE CONSTRUCTION AND ARE NOT MEANT TO ENSURE COMPLETE COMPLIANCE. A COPY OF INSPECTION COMMENTS WILL GENERALLY BE PROVIDED TO THE CONTRACTOR REFLECTING DISCREPANCIES NOTED; NO OTHER OBSERVATIONS ARE TO BE IMPLIED OR INFERRED. INSPECTIONS DO NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY TO COMPLY WITH THE APPROVED PLANS OR CONTRACT DOCUMENTS. 123.3. REVISIONS, REPAIRS AND FIELD CHANGES ARE AUTHORIZED ONLY WHEN IN WRITING, SIGNED AND SEALED BY A PROFESSIONAL ENGINEER WITH THIS OFFICE. WHEN SO ISSUED, THEY BECOME INCORPORATED INTO THE PLANS AND CONTRACT DOCUMENTS. 124. SITE VISITS 124.1. SITE VISITS ARE TO OBSERVE GENERAL PROGRESS AND QUALITY OF CONSTRUCTION AND ARE NOT INTENDED AS DETAILED INSPECTIONS, NOR DO THEY IMPLY EXHAUSTIVE REVIEW OF ALL WORK OR CODE COMPLIANCE, THE ENGINEER MAKES NO WARRANTY OR GUARANTEE REGARDING THE CONDITION, PERFORMANCE, OR CODE COMPLIANCE OF THE WORK OBSERVED. 125. SPECIAL INSPECTIONS 125.1. WHERE REQUIRED BY THE APPLICABLE BUILDING CODE, A STATEMENT OF SPECIAL INSPECTIONS SHALL BE PREPARED IN ACCORDANCE WITH IBC SECTION 1705 AND SUBMITTED TO THE AUTHORITY HAVING JURISDICTION (AHJ) PRIOR TO PERMIT ISSUANCE. SPECIAL INSPECTIONS ARE SEPARATE FROM AND IN ADDITION TO THE GENERAL INSPECTIONS REFERENCED IN NOTE 123. 125.2. THE CONTRACTOR, OR OWNER, OR OWNER'S REPRESENTATIVE SHALL EMPLOY A SPECIAL INSPECTOR TO PERFORM REQUIRED INSPECTIONS. THE SPECIAL INSPECTOR SHALL SUBMIT REPORTS TO THE EOR, ARCHITECT, AND AHJ AS REQUIRED, WITH A FINAL REPORT SUBMITTED TO THE AHJ PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. 126. WATERPROOFING 126A. WATERPROOFING, MOISTURE PROOFING, FLASHING, SEALANTS, AND RELATED DETAILS ARE NOT INCLUDED IN THE STRUCTURAL SCOPE AND SHALL BE DESIGNED BY OTHERS. THE CONTRACTOR SHALL COORDINATE WITH APPLICABLE TRADES AND REPORT ANY CONFLICTS WITH THE STRUCTURAL DESIGN TO THE FOR PRIOR TO CONSTRUCTION. F j4, * * ........................... .ALIAKSEI PATSEVICH ........................... ,o % 130521 r • �,o •�'• / /� E N SE>-.', �,, • N• n .NN %C' S ••• S G N 1 O E ONAL AL w H c9 z 0 J r • 71! 2 0 2 R W W Z_ 2 W M IT .4 4* 1-1 LL_ J Lu CL m 2: °' O OkD U r*_ L7 x Z �_ i--4 LL! Lu Lu z 1-4 Lu a Z W C)j� O CD rsi .--i r,� -i ,'I- _ ,--i U ' X -' O w CI, v) '. Q L 0- m ,--i 00 fV of [V lD Nr .--i [V REVISIONS 0 DATE BY PROJECT NAME 101 CROSS CREEK GARAGE ADDITION 1 . ow�1 SRO . 1. 101 CROSS CREEK DR GRAPEVINE, TX PROJECT NUMBER S26129 CHECKED BY - AP SHEET DATE - 05/04/2026 Z O U Lo w 0 SCALE 24X36 SHEET:1/2"=1'-0" (n Lu 0 z _J af ZD of (n -J 9 z Lu GN301. GENERAL FRAMING NOTES, TYP DETAILS, AND SCHEDULES 301. GENERAL 301.1. REFER TO GENERAL STRUCTURAL NOTES (SECTIONS 100 THROUGH 127) FOR ALL ADDITIONAL REQUIREMENTS APPLICABLE TO MATERIALS, FASTENERS, CONNECTORS, INSPECTIONS, DELEGATED DESIGN, SUBMITTALS, AND ALL OTHER WORK NOT SPECIFICALLY ADDRESSED IN THESE FRAMING NOTES. IN CASES OF CONFLICT THE MORE STRINGENT REQUIREMENT SHALL GOVERN PER NOTE 100.4. 301.2. FRAMING SHALL CONFORM WITH THE APPLICABLE BUILDING CODE AND THE WOOD FRAME CONSTRUCTION MANUAL (WFCM) PUBLISHED BY THE AMERICAN WOOD COUNCIL (AWC). 301.3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ELEVATIONS WITH THE ARCHITECTURAL DRAWINGS PRIOR TO CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED IN WRITING TO THE ARCHITECT AND THE FOR PRIOR TO CONSTRUCTION OF THE AFFECTED WORK. (SEE NOTE 100.2). 301.4. THE CONTRACTOR SHALL LOCATE ALL OPENINGS AND PENETRATIONS AND VERIFY NO CONFLICT WITH STRUCTURAL FRAMING PRIOR TO CONSTRUCTION. MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS ARE BY OTHERS. SEE SECTION 304 FOR FRAMING PENETRATION REQUIREMENTS. 301.5. FIREBLOCKING AND DRAFTSTOPPING REQUIREMENTS ARE BY OTHERS AND SHALL CONFORM WITH THE APPLICABLE BUILDING CODE. 301.6. STANDARD NOTES DETAILS AND SCHEDULES ARE GUIDELINES FOR TYPICAL CONDITIONS. WHERE SPECIFIC NOTES, DETAILS, OR SCHEDULES ARE SHOWN ON THE PLANS, THOSE SHALL GOVERN. (SEE NOTE 100.4). 302. FASTENERS 302.1. ALL FASTENER REQUIREMENTS -- INCLUDING CORROSION PROTECTION FOR FASTENERS IN CONTACT WITH PRESSURE -TREATED (PT) OR FIRE -RETARDANT -TREATED (FRT) WOOD, GALVANIZATION STANDARDS, STAINLESS STEEL GRADES, AND PROHIBITED FASTENER TYPES -- SHALL BE PER NOTES 110.1 THROUGH 110.12 OF THE GENERAL STRUCTURAL NOTES. 302.2. NAILS SHALL BE COMMON OR SINKER NAILS UNLESS NOTED OTHERWISE, PNEUMATICALLY DRIVEN NAILS SHALL MATCH THE REQUIRED LENGTH AND DIAMETER OF THE SPECIFIED NAIL AND SHALL MEET THE REQUIREMENTS OF NOTE 110.4. 302.3. TYPICAL NAIL SIZE: 0.131"X2-1/2", 0.131"x3", 0.131"x3-1/2", 0.148"x3", 0.148"x3-1/4", 0.162"X3-1/2". ADDITIONAL SIZES MAY BE REQUIRED PER SPECIFIC PLAN OR DETAIL CALLOUTS. 302.4. EDGE DISTANCES, END DISTANCES, AND FASTENER SPACING SHALL BE SUFFICIENT TO PREVENT SPLITTING OF THE WOOD PER NDS REQUIREMENTS. TOE NAILS SHALL BE DRIVEN AT AN APPROXIMATE 300 ANGLE WITH THE MEMBER AND STARTED APPROXIMATELY 1/3 NAIL LENGTH FROM THE MEMBER END. 302.5. AT SHEATHING NAILING, IF MORE THAN 20% OF NAILS IN ANY PANEL ARE OVERDRIVEN BY MORE THAN 1/16% PROVIDE ONE ADDITIONAL NAIL FOR EVERY TWO OVERDRIVEN NAILS. 302.6. NAILS AT MECHANICAL CONNECTORS SHALL COMPLY WITH THE TYPE, SIZE, AND QUANTITY SPECIFIED BY THE CONNECTOR MANUFACTURER TO ACHIEVE THE MAXIMUM SPECIFIED LOAD CAPACITY. ALL CONNECTOR FASTENER REQUIREMENTS AND SUBSTITUTION RESTRICTIONS ARE PER NOTES 111.4 AND 111.5. 302.7. TYPICAL NAILING REQUIREMENTS SHALL BE AS SPECIFIED PER IBC TABLE 2304.10.1, IRC TABLE R602.3(1) OR PER THE TYPICAL NAILING SCHEDULE BELOW, UNLESS NOTED OTHERWISE PER PLAN, SHEAR WALL SCHEDULE (NOTE 409), OR SPECIFIC DETAILS. 302.8. TYPICAL NAILING SCHEDULE: TYPICAL NAILING SCHEDULE (5) BLOCKING BETWEEN RAFTERS TO TOP PLATE('') TOE NAIL 3"XO.131" @ 6" O.C. (MIN 3) "I I CEILING JOISTS TO TOP PLATE TOE NAIL (3) 3"XO.131", PER JOIST I CEILING JOISTS TO RAFTER OR LAPS OVER PARTITION FACE NAIL (4) 3"XO.131" I COLLAR TIE TO RAFTER FACE NAIL (4) 3"XO.131" ROOF I RAFTER OR ROOF TRUSS TO TOP PLATE AT BEARING WALL TOE NAIL (4) 3"XO.131'. TWO PER SIDE, ADD'L HZJ') AND CEILING ROOF RAFTERS TO RIDGE, VALLEY OR HIP TOE NAIL (4) 3"XO.131" OR END NAIL (3) 3"X0.131' TYPICAL: 2-1/2"X0.131" Ca) 6" O.C. EDGE, C& 12" O.C. FIELD ROOF SHEATHING TO RAFTER OR TRUSS WITHIN 4'-O" FROM EAVES, VALLEYS, HIPS AND RIDGES: 6" O.C. FIELD TO GABLE END WALLS: 4" O.C. ROOF BRACE TO TOP PLATE TOE NAIL (4) 3"XC.131". TWO PER SIDE BUILT-UP STUDS FACE NAIL 3"X0.131" @ 6"O.C. STAGGERED ABUTTING STUDS AT INTERSECTING WALL CORNERS FACE NAIL 3"XO.131" @ 6"O.C. BUILT-UP MULTIPLY HEADER HEADER, SAWN LUMBER 2X FACE NAIL 3-1/2"X0.162" @ 12"O.C. ALONG EA EDGE, EA PLY OF PIECES WITH MAX 1/2" SPACER HEADER"' I BUILT-UP MULTI -PLY HEADER, ENGINEERED LUMBER REF ENGINEERED LUMBER NAILING DETAIL I CONTINUOUS HEADER TO STUD TOE NAIL (4) 2-1/2"X0.131" I ADJACENT FULL -HEIGHT KING STUD TO END OF HEADER END NAIL (6) 3"XO.131" WALL I TOP PLATE TO TOP PLATE FACE NAIL 3"XO.131" @ 12" O.C. DOUPLE TOP PLATE LAP SPLICE MINIMUM 24" LAP SPLICE LENGTH WITH MINIMUM (12) 3"X0.131" IN LAPPED AREA I TOP PLATES LAP AT CORNERS AND INTERSECTIONS FACE NAIL (3) 3"X0.131" I BOTTOM PLATE TO RIM, JOIST OR BLOCKING ('1(B) FACE NAIL 3-1/2"10.131" @ 12" CI TOP OR BOTTOM PLATE TO STUD (Bl TOE NAIL (4) 3"X0.131" (B) OR END NAIL (3) 3"10.131"(B) WALL SHEATHING TO WALL STUDS FACE NAIL 2 1/2"XO.131" @ 6" O.C. EDGE, @ 12" O.C. FIELD MAX (Sl(1) JOISTS TO TOP OF PLATE OR TOP OF BEAM/GIRDER TOE NAIL (3) 3"X0.131", OR FLANGE NAIL AT 1-JOISTS I RIM JOIST, BAND JOIST OR BLOCKING TO PLATE BELOW TOE NAIL 3"X0.131" @ 6" O.C. MAX (MIN 3) r596) I RIM JOIST TO END OF FLOOR JOISTS FACE NAIL (1) 3"XD.131" TOP AND BOT FLANGE FLOOR SHEATHING (3/4" MAX THICKNESS) TO FLOOR FACE NAIL 2 1/2"10.131" @ 6" O.C. EDGE, @ 12" O.C. FIELD (6) FLOOR JOISTS OR BLOCKING FLOOR SHEATHING (7/8" MIN - 1 1/4" MAX) TO FLOOR FACE NAIL 3"XO.148" @ 6" O.C. EDGE, @ 12" O.C. FIELD 16) JOISTS OR BLOCKING I BRIDGING OR BLOCKING TO ADJACENT JOIST OR TRUSS TOE NAIL (2) 3"XO.131" EA END RIM TO JOIST END NAIL (4) 3"XO.131" BUILT-UP MULTI -PLY 2X BEAMS FACE NAIL 3-1/2"10.162" @ 12"O.C. ALONG EA EDGE, EA PLY OF HEADER"' BUILT-UP MULTI -PLY ENGINEERED LUMBER BEAM REF ENGINEERED LUMBER FASTENING NOTE 303.12.2 NOTES: (1) ALL NAILS SHALL BE OF THE SIZE AND TYPE SPECIFIED. (2) SUBSTITUTION WITH PNEUMATICALLY DRIVEN NAILS 15 PERMITTED, PROVIDED THEY MATCH THE SPECIFIED LENGTH AND DIAMETER, AND MEET THE EQUIVALENT STRENGTH REQUIREMENTS OUTLINED IN THE FRAMING AND GENERAL NOTES. (3) PROVIDE H2.5 TIE AT RAFTER OR TRUSS TO T/PLATE CONNECTION. 4 OFFSET NAILS MIN 3" AT EACH ADJACENT PLY. (5) REFER TO SHEARWALL SCHEDULE FOR NAILING REQUIREMENTS AT SHEARWALLS. (6) WHERE FLOOR FRAMING OCCURS OVER SHEARWALL, FLOOR SHEATHING TO RIM OR BLOCKING CONNECTIONS SHALL CONFORM TO THE NAILING REQUIREMENTS SPECIFIED IN THE SHEARWALL SCHEDULE. (7) 12" O.C. FIELD NAILING IS ACCEPTABLE FOR STUDS SPACED AT 16" O.C. OR LESS. WHEN STUDS ARE SPACED APART MORE THAN 16" O.C. FIELD NAILING SHALL BE 6" O.C. (8) ADDITIONAL NAILS REQUIRED AT EXTERIOR WALLS TALLER THAN 10'4". REFER TO EXT WALL STUD SCHEDULE (NOTE 309.10.1) 303. GENERAL FRAMING 303.1. ALL LUMBER, SHEATHING, AND SIDING LOCATED LESS THAN 6 INCHES FROM FINISHED GRADE, EXPOSED TO WEATHER, OR IN DIRECT CONTACT WITH CONCRETE SHALL BE PRESERVATIVE -TREATED PER NOTE 103.5. FIELD CUTS, NOTCHES, AND DRILLED HOLES IN TREATED LUMBER SHALL BE TREATED IN THE FIELD PER AWPA M4. 303.2. DIMENSIONAL LUMBER SHALL MEET THE REQUIREMENTS OF NOTE 103. SPECIES AND MINIMUM REQUIRED GRADES FOR THIS PROJECT SHALL BE AS FOLLOWS: 303.2.1. SPECIES: SOUTHERN YELLOW PINE (SYP) 303.2.2. GRADE: SAWN MEMBER MINIMUM GRADE STUDS PER WALL STUD SCHEDULE, #2 GRADE REQUIRED AT PORTAL FRAMES PLATES (TOP AND SILL) #3 OR BETTER FLOOR JOISTS #2 OR BETTER RAFTERS, HIPS, VALLEYS, RIDGES #2 OR BETTER ROOF BRACES, PURLINS, COLLAR TIES #2 OR BETTER BEAMS, HEADERS (SAWN) #2 OR BETTER POSTS, COLUMNS (SAWN) #2 OR BETTER 303.3. ENGINEERED WOOD PRODUCTS SHALL MEET THE MANUFACTURING, LABELING, INSTALLATION, STORAGE, AND FIELD MODIFICATION REQUIREMENTS OF NOTES 104.1 THROUGH 104,9 (EWP) AND NOTES 105.1 THROUGH 105.7 (GLULAM). MINIMUM GRADES FOR THIS PROJECT SHALL BE AS FOLLOWS: ENGINEERED WOOD PRODUCT MINIMUM GRADE/SPECIFICATION NOTES I RIM BOARD 1-1/4" LSL 1.3E (TYPICAL) 1-1/2" LSL (1.5E) OR 1-3/4" LSL (1.55E) MAY BE REQUIRED AT SHEARWALLS. REF SHEARWALL SCHEDULE LVL HEADERS, BEAMS, JOISTS LVL 2,OE MIN I LSL HEADERS, BEAMS, JOISTS LSL 1.55E MIN I PSL HEADERS, BEAMS PSL 2.2E MIN LSL STUDS LSL 1.3E (1-1/2" WIDE) LSL 1.55E (1-3/4" WIDE) PSL COLUMNS PSL 1.8E MIN 24F-V4 DF (SINGLE SPAN) GLULAM 24F-V8 OF (MULTISPAN OR CANTILEVER) 303.4. SHEATHING PANEL GRADES AND THICKNESS - UNLESS OTHERWISE NOTED, PANELS SHALL BE AS FOLLOWS: APPLICATION MINIMUM PERFORMANCE MIN SPAN RATING ADDITIONAL NOTES CATEGORY WALL SHEATHING 7/16" 24/16 EXPOSURE 1 I ROOF SHEATHING - SHINGLE/METAL 7/16" 24/16 EXPOSURE 1 ROOF SHEATHING -TILE 15/32" 32/16 EXPOSURE 1 FLOOR SHEATHING 23/32" 48/24 EXPOSURE 1, T&G, GLUED AND NAILED I DECK SHEATHING EXPOSED TO WEATHER 23/32" 48/24 EXTERIOR RATED, T&G, REF NOTE 108.3 1 303.5. FRAMING SHALL PROVIDE A CONTINUOUS LOAD PATH TO TRANSFER ALL VERTICAL AND LATERAL LOADS FROM THE ROOF, WALL, CEILING, AND FLOOR SYSTEMS TO THE FOUNDATION. 303.6. WHERE JOISTS, TRUSSES, OR RAFTERS ARE SPACED MORE THAN 16" O.C. AND THE BEARING STUDS BELOW ARE SPACED AT 24" O.C., SUCH MEMBERS SHALL BEAR WITHIN 5" OF THE STUDS BENEATH. 303.7. ALL BEAMS SHALL BE SUPPORTED AT EACH END BY BUNDLED STUDS (MINIMUM 2) OR A POST WHOSE COMBINED WIDTH EQUALS OR EXCEEDS THE FULL WIDTH OF THE BEAM, UNO. EACH BEAM SUPPORT SHALL HAVE A CONTINUOUS LOAD PATH TO THE FOUNDATION OR TO ADEQUATELY SIZED SUPPORTING BEAMS OR HEADERS BELOW. FOR PROJECTS WITH FLOOR FRAMING (MULTI -STORY OR CRAWLSPACE), VERTICAL SUPPORT SHALL BE CONTINUOUS THROUGH FLOOR FRAMING VIA VERTICAL CRUSH BLOCKING (VCB). SEE NOTE 307.11. 303.8. BEAM FRAMING ELEVATION NOTATION PER PLAN 303.8.1. "DROPPED BEAM" or "DB": TOP OF BEAM EQUAL TO BOTTOM OF JOISTS. 303.8.2. "TOP FLUSH" or "TF": TOP OF BEAM EQUAL TO TOP OF JOISTS; BOTTOM VARIES. 303.8.3. "BOTTOM FLUSH" or "BF": BOTTOM OF BEAM EQUAL TO BOTTOM OF JOISTS; TOP VARIES. 303.9. FRAMING ELEVATION DEFAULTS (UNO PER PLAN): FLOOR BEAMS - TOP FLUSH. CEILING BEAMS - BOTTOM FLUSH. PORCH / PATIO / BALCONY BEAMS - DROPPED. ROOF BEAMS - TOP FLUSH. 303.10. BEAMS SHALL HAVE FULL BEARING OVER TOP PLATES. WHERE BEAMS ON OPPOSITE SIDES OF A WALL ARE IN LINE, EACH SHALL HAVE 1/2 PLATE WIDTH FOR BEARING, UNO PER PLAN. AT PERIMETER WALLS, BEAMS SHALL HAVE FULL BEARING LESS RIM BOARD WHERE APPLICABLE. UNDER NO CIRCUMSTANCES SHALL RAFTERS, JOISTS, BEAMS, OR GIRDERS BEAR LESS THAN 1-1/2" AT ANY SUPPORT. 303.11. HORIZONTAL STRAPS INDICATED ON FRAMING PLANS SHALL BE CENTERED OVER THE TOP PLATE, BEAM, OR BLOCKING, UNO. STRAP LENGTH PER PLAN. 303.12. MULTI -PLY BEAM AND HEADER FASTENING 303.12.1. ALL MULTI -PLY SAWN LUMBER 2x BEAMS SHALL BE FACE -NAILED TOGETHER PER THE TYPICAL NAILING SCHEDULE (NOTE 302.8). 303.12.2. ALL MULTI -PLY ENGINEERED LUMBER BEAMS SHALL BE CONNECTED TOGETHER AS FOLLOWS: FASTENERS SHALL BE STAGGERED WHEN REQUIRED ON BOTH SIDES EQ SPACING BETWEEN ROWS OF FASTENERS FASTENERS PER TABLE LOAD MUST BE APPLIED EVENLY ACROSS ENTIRE BEAM WIDTH. REF DETAIL FOR POINT LOAD CONNECTION AT MULTIPLY BEAMS AT BEAM TO BEAM CONNECTION. FASTENER INSTALLATION REQUIREMENTS FOR MULTIPLE PLY LVL BEAMS FASTENERS MAX UNIFORM LOAD PLY # OF TOTAL ASSEMBLY SECTION WIDTH PLIES WIDTH FASTENER TYPE # ROWS MAX 0 C LOCATION APPLIED TO EITHER (') SIDE MEMBER PLF SPACING 10D (3"X0.148") 3 1'-0" ONE FACE 865 ,_ 1/2" DIA THROUGH BOLT(') 2 2-0" - 780 2 3-1/2" 111���� 160 SINKER (3 1/4" X 0.148') 2(2) 1'-0" ONE FACE 575 / 865(') SDS SCREW (3-1/2"X1/4") 2 T-0" ONE FACE 870 SDW22 SCREW (3-3/8-XC.22") 2 2'-0" ONE FACE 680 lOD (3"X0.148") 3 V-W BOTH FACES 110 1/1" DIA THROUGH BOLT"') 2 V-4" - 880 3 5-1/4" III��� ]I 16D SINKER (3 1/4" X 0.148") 2i2) 1'-0" BOTH FACES 430 / 650(') I= SDS SCREW (3-1/2"Xl/4") 2 V-4" BOTH FACES 980 1-3/4" SDW22 SCREW (5"X0.2V) 2 1'-4" ONE FACE 935 LVL � 112" DIA THROUGH BOLT{') 2 1'-4" - 780 4 7" Hl' SDS SCREW (3.1/2"X6") 2 l'-4" BOTH FACES 1,020 �, SDW22 SCREW (6-3/4"X0.22") 2 1,-4 , ONE FACE 830 1 1 1 1 ----, 1/2" DIA THROUGH BOLT(1) 2 1'-0"- 820 5 8-3/4" ----I SDWS22800 SCREW (8'XO.22') 2 1'-0" BOTH FACES 400 (1) THROUGH BOLTS SHALL BE A307. PROVIDE STANDARD CUT WASHERS AND NUT. BOLT HOLES TO BE 9/16" MAX. (2) # OF ROWS SPECIFIED IS FOR BEAM DEPTHS OF 14" OR LESS. FOR BEAMS OVER 14" PROVIDE ADDITIONAL ROW OF FASTENERS (3) FOR APPLICATIONS WHERE APPLIED LOAD EXCEEDS MAX SPECIFIED LOAD, FASTENER SPACING CAN BE REDUCED TO V-0" AND INCREASED PROPORTIONALLY 303.13. AT BEAM TO BEAM CONNECTIONS, IN ADDITION TO THE FASTENERS REQUIRED FOR THE HANGER INSTALLATION, PROVIDE ADDITIONAL FASTENERS AS FOLLOWS: 4STENERS PER TABLE. BOTH SIDES OF BEAM BEAMS PER PLAN HANGER, AS REQUIRED FASTENER INSTALLATION REQUIREMENTS AT CONCENTRATED LOADS FOR MULTIPLE PLY LVL BEAMS FASTENERS MAX POINT LOAD PLY # OF TOTAL ASSEMBLY SECTION APPLIED TO EITHER PER FACE 13) WIDTH PLIES WIDTH FASTENER TYPE # FASTENERS LOCATIOW) SIDE MEMBER (LBS) _ IOD (3"X0.148") 12(1) ONE FACE 2,230 - I 16D SINKER (3 114" X 0.148") 12(1) ONE FACE 2,230 2 3 1/2" I SDS SCREW (3-1/2"X1/4") 4(2) ONE FACE 2,720 �Io SDW22 SCREW (3-3/8"XO.22") 4(2) ONE FACE 3,200 IOD (3"X0.148") 1211) BOTH FACES 1,675 3 5-1/4" I 16D SINKER 3 1/4" X 0.148" 12(') BOTH FACES 1,675 ,]I I SDS SCREW (3-1/2"XI/4") 4(2) BOTH FACES 2,040 1-3/4" � ' SDW22 SCREW (5"X0.22") 4(2) ONE FACE 1,800 LVL r`%% If SDS SCREW (3-1/2"X6") 4(2) BOTH FACES 2,225 4 7" l�, SDW22 SCREW (6-3/4"X0.2211) 4(2) ONE FACE 1,600 � I I I 1 5 8 3/4" I I SDWS22800 SCREW (8"XO.22") 16 BOTH FACES 3,200 Il � (1) # OF FASTENERS CANCREASEDI N BE IUP TO 24, MAX APPLIED POINT LOAD IS INCREASED PROPORTIONALLY TO THE ADDED FASTENERS. (2) # OF FASTENERS CAN BE INCREASED UP TO 8, 14AX APPLIED POINT LOAD IS INCREASED PROPORTIONALLY TO THE ADDED FASTENERS. (3) # OF FASTENERS SPECIFIED PER FACE SHALL BE EVENLY DISTRIBUTED ON BOTH SIDES OF THE HANGER. FOR EXAMPLE, IF 12 FASTENERS ARE REQUIRED, 6 SHALL BE INSTALLED ON THE LEFT SIDE AND 6 ON THE RIGHT SIDE OF THE HANGER. (4) WHEN FASTENER PLACEMENT LOCATION IS INDICATED AS "BOTH FACES," THE TOTAL NUMBER OF FASTENERS SHALL BE DOUBLED FROM THE QUANTITY SHOWN PER FACE 303.14. CONNECTORS AND HANGER SCHEDULES 303.14.1. ALL MECHANICAL CONNECTORS (JOIST HANGERS, STRAPS, POST BASES, HOLDOWNS, AND SIMILAR HARDWARE) SHALL MEET ALL REQUIREMENTS OF NOTES 111.1 THROUGH 111.9, INCLUDING CORROSION PROTECTION, MANUFACTURER APPROVAL, FASTENER COMPATIBILITY, AND INSTALLATION REQUIREMENTS. CONNECTOR SUBSTITUTIONS REQUIRE PRIOR WRITTEN APPROVAL FROM THE FOR PER NOTE 111.2 303.14.2. WHERE A HANGER IS INDICATED PER PLAN, HANGERS SHALL BE SELECTED FROM THE SCHEDULES BELOW UNLESS NOTED OTHERWISE ON THE PLANS OR IN SPECIFIC DETAILS. TYPICAL HANGERS SHALL BE REGULAR FACE -MOUNTED UNLESS OTHERWISE NOTED. 303.14.3. 2X SAWN LUMBER, 4X AND 6X TIMBER HANGER SCHEDULE: LUMBER HANGER SCHEDULE I TIMBER HANGER SCHEDULE REGULAR CONCEALED TOP FLANGE('' SLOPED I TIMBER REGULAR CONCEALED OP FLANGE;' SLOPED L SIZER I SIZE I MODEL NO. I MODEL NO. ITMODEL N0. I MODEL NO. MODEL NO . MODEL NO. MODEL NO. MODEL NO. 4X TIMBER 2X LUMBER I 4X6 LUS46 HUC46 WP46 - 2X6 LUS26 LUC26Z LB26 LRU26Z I 4X8 LUS48 HUC48 WP48 - 2X8 LUS28 LUC26Z LB28 LRU28Z I 4X10 LU5410 HUC410 BA410 LSSR410Z 2X10 LUS210 LUC210Z LB210AZ LRU21OZ I 4XI2 LUS410 HUC412 BA412 . 2X12 LUS210 LUC210Z L6212AZ LRU212Z I 6X TIMBER 2-PLY 2X LUMBER I 6X6 U66 HUC66 WP66 - 2-PLY 2X6 LUS26-2 HUC26-2 WP26-2 - I 6X8 U66 HUC68 WP68 . 2-PLY 2X8 LUS28-2 HUC28-2 WP28-2 - I 6X10 U610 HUC610 WP610 - 2-PLY 2X10 LUS210-2 HUC210-2 WP210-2 LSSR210-2Z I 6X12 HU612 HUC612 HWPH612 - 2-PLY 2X12 WS210-2 HUC212-2 WP212-2 - I NOTES: 3 PLY 2X LUMBER (1) FOR INSTALLATION OVER WOOD NAILER ON TOP OF CONCRETE OR STEEL BEAMS FOLLOW MANUFACTURER REQUIREMENTS FOR 3-PLY 2X6 LUS26-3 HUC26-3 - QUANTITY AND LOCATION OF FASTENERS 3-PLY 2X8 LUS28-3 HUC26.3 - - 3-PLY 2X10 WS210.3 HUC210-3 3-PLY ZX12 W5210.3 HUC212.3 303.14.4. TJI JOIST AND ENGINEERED LUMBER HANGER SCHEDULE: TJI JOISTS HANGER SCHEDULE ENGINEERED LUMBER HANGER SCHEDULE (LVL, LSL, PSL) REGULAR TOP FLANGE^') SLOPED(2) REGULAR JOIST BEAM DEPTH BEAM WIDTH`3j SIZE MODEL NO. MODEL N0. MODEL N0. MODEL N0. 1 3/4" MIU1.81/9 210 SERIES 3 112' HHUS410 9 1/4" OR 9 1/2" 91/2" IUS2.06/9.5 ITS2.06/9.5 LSSR2.IZ 51/4" HGUS5.50/10 11 7/8" IUS2.06/11.88 ITS2.06/11.88 LSSR2.1Z 7" HGUS7.25/10 14" IUS2.06/14 ITS2.06/14 LSSR2.1Z 1 3/4" MIU1.81/11 16" IUS2.06/16 ITS2.06/16 LSSR2.1Z 3 112" HHU5410 11 1/4" OR 11 7/8" DOUBLE 9 1/2" MIU4.28/9 MIT4.28/9.5 LSU4.28 5 1/4" HGUS5.50/12 DOUBLE 11 7/8" MIU4.28/11 MIT4.28/11.88 LSU4.28 7" HGUS7.25/12 DOUBLE 14" MIU4.28/14 MIT4.28/14 LSU4.28 1 3/4" MIU1.81114 DOUBLE 16" MIU4.28/16 BA4.28/16 LSU4.28 3 112' HHUS410 230/360 SERIES 14" 5 1/4" HGUS5.50/14 91/2" IUS2.37/9.5 ITS2.37/9.5 LSSR2.37Z 7" HGUS7.25/14 11 7/8" IUS2.37/11.88 ITS2.37/11.88 LSSR2,37Z 1 3/4" MIU1.81/16 14" IUS2.37/14 ITS2.37/14 LSSR2.37Z 3 1/2" HGUS414 16" IUS2.37/16 ITS2.37/16 LSSR2.37Z 16" 5 1/4" HGUS5.50/14 DOUBLE 9 1/2" MIU4.75/9 MIT359.5-2 LSSR3510-2 7" HGUS7.25/14 DOUBLE 11 7/8" MIU4.75/11 MIT3511.88-2 LSSR3510-2 1 3/4" MIUI.81/18 DOUBLE 14" MIU4.75/14 MIT3514-2 LSSR3510-2 3 1/2" HGUS414 DOUBLE 16" MIU4.75/16 MIT4.75/16 LSSR3510-2 18" 5 1/4" HGUS5.50/14 560 SERIES 7" HGUS7.25/14 11 7/8" IUS3.56/11.88 ITS3.56/11.88 LSSR41OZ NOTES: 14" IU53.56/14 ITS3.56/14 LSSR41OZ (1) FOR INSTALLATION OVER WOOD NAILER ON TOP OF CONCRETE OR STEEL BEAMS FOLLOW MANUFACTURER REQUIREMENTS FOR QUANTITY 16" IUS3.56/16 ITS3.56/16 LSSR41OZ AND LOCATION OF FASTENERS DOUBLE 11 7/8" HU412-2 HB7.12/11.88 - (2) SLOPED HANGERS REQUIRE INSTALLATION OF 4" WEB STIFFENERS ON BOTH SIDES OF THE JOIST AT HANGER. ATTACH W/ (4) 0.148" DIA NAILS DOUBLE 14" HU414-2 HB7.12/14 - (3) AT BUILT-UP BEAMS HANGERS SHALL MATCH OVERALL WIDTH OF THE DOUBLE 16" HU414-2 H67.12/16 BUILT UP BEAM ASSEMBLY: 2-PLY 1 3/4" = 3 112" 3-PLY 1 3/4" = 5 1/4" 4-PLY 1 3/4" = 7" 303.15. CEILING/ATTIC FRAMING 303.15.1. TYPICAL CEILING AND ATTIC FRAMING IS BASED ON STANDARD SPAN TABLES FOR DIMENSIONAL LUMBER. THE CONTRACTOR SHALL VERIFY WHETHER ATTIC AREAS ARE DESIGNATED FOR LIMITED STORAGE OR NO STORAGE (SEE NOTE 117.1.2 AND 117.1.3 FOR APPLICABLE LIVE LOADS), AND SHALL CONFIRM THE LOCATION OF HVAC EQUIPMENT RELATIVE TO THESE AREAS. UNLESS SPECIFICALLY NOTED OTHERWISE ON THE CEILING FRAMING PLAN, ALL ATTIC AREAS CAPABLE OF ACCOMMODATING A BOX UP TO 42" IN HEIGHT AND 24" IN WIDTH SHALL BE CONSIDERED DESIGNED FOR LIMITED STORAGE, IF HVAC UNITS ARE LOCATED IN SPACES DESIGNATED FOR NO STORAGE, THE CONTRACTOR SHALL NOTIFY THE FOR FOR REVIEW PRIOR TO PROCEEDING. (SEE ALSO NOTES 106,9, 117.1.2, AND 117.1.3.) 303.15.2, PROVIDE ATTIC ACCESS OPENING MINIMUM 22"x30" FOR ATTIC AREAS WITH >_30" CLEAR HEIGHT OVER ?30 SF. LOCATE IN AN ACCESSIBLE LOCATION AND MAINTAIN MINIMUM 30" CLEAR HEADROOM ABOVE OPENING. 303.16. MAXIMUM ALLOWABLE LUMBER SPANS SHALL BE DETERMINED BASED ON THEIR DESIGNATED USE, SUPPORTED MATERIAL AND APPLICABLE DEFLECTION LIMITS PER NOTES 116 THROUGH 118. SPAN LIMITS SHALL BE AS FOLLOWS: LUMBER SPAN TABLE (SYP #2) SPACING (IN O.C.) APPLICATION SIZE I` 12 I 16 I 19.2 I 24 CEILING NOT ATTACHED TO RAFTERS DL=10PSF, LL=20PSF, L/6=180 I 2X6 15'-7° 13'-6" 12'-3" 11'-0" I 2X8 19'-8" 17-1" 15'-7" 13'-11" RAFTERS WITH 2X10 23'-5" 20'-3" 18'-6" 16'-6" SHINGLE OR I 2X12 26-0" 23'-10" 21'-9" 19'-6" METAL ROOF I CEILING ATTACHED TO RAFTERS DL=20PSF, LL=20PSF, L/A=240 COVERINGS 2X6 13'-6° 11'-8" 10'-8" 9'-6" I 2X8 17-1" 14'-9" 13'-6" 12'-I" I 2X10 20'-3" 17-6" 16-0" 14'-4" 2X12 23'-10" 20'-8" 18'-10" 16-10" CEILING NOT ATTACHED TO RAFTERS DL=20PSF, LL=20PSF, L/A=180 I 2X6 13'-6' 11'-8" 10'-8" (') T-6• (1) I 2X8 17'-I" 14'-9" IT-6" (') 12'-1" (') I 2X10 20'-3" 17'-6" 16'-0" (') 14'-4" (') RAFTERS WITH I 2X12 2T-10" 20'-8" 18'-10" (') 16-1O" "' TILE ROOF COVERINGS I CEILING ATTACHED TO RAFTERS DL=25PSF, LL=20PSF, L/A=240 I 2X6 11'-6" 10'-6" 9'-6" (') 8'-6" (1) I 2X8 15'-4" IT-4" 12'-2" (1) 11'-0" (1) I 2X10 18'-6" 16'-0" 14'-6" (1) IT-0" (') 2X12 21'-6" is,-10" 17-2" (') IT-4" (') UNINHABITABLE ATTIC WITH LIMITED STORAGE DL=10PSF, LL=20PSF, L16=240 I 2X6 13'-1I' 12'-O" 11'-0" 9'-10" I 2X8 1T-7" 15'-3" 13'-11" 12'-6" I 2X10 20'-11" 16'-1" 16'-6" 14'-9" 2X12 24'-8" 21'-4" 19'-3" IT-5" CEILING JOISTS I UNINHABITABLE ATTIC WITHOUT STORAGE DL=5PSF, LL=IOPSF, L/6=240 I 2X6 18'-8" 16'-11- 15'-7" 13'-1" I 2X8 24'-7" 21'-7" 19'-8" IT-7" I 2X10 26-0" 25'-7" 23'-5" 20'-I1" I 2X12 26-0" 2641 26'4- 24'-8" NOTES: (1) TYPICAL RAFTER SPACING FOR TILE ROOF IS LIMITED TO 16" O C. MAX 304. FRAMING PENETRATIONS 304.1. NOTCHING OF STUDS SHALL NOT OCCUR IN THE MIDDLE 1/3 OF THE STUD HEIGHT. MAXIMUM STUD NOTCHING AND BORING SHALL BE AS FOLLOWS: EXTERIOR OR EXTERIOR OR BEARING WALL NON -BEARING WALL BEARING WALL NON -BEARING WALL / - (25% WIDTH MAX) (40 /o WIDTH MAX) (40% WIDTH MAX) {60 /o WIDTH MAX) P. �1� 1 7/16" �� 2 1/8"I t . . � 7/8 1 7/ 16 0� 6 y In 4 ✓ O 'p, O � �� 1/2" 1/2' 1/2" 1/2" J y I � � �� „ "' 2 3/16 3 5/16 d 1 3/8" 2 3/16" X �✓/ �f 1(� N _ _ __�,__ --A--- 304.2. MAXIMUM ALLOWED 2X SAWN LUMBER RAFTERS, JOISTS AND BEAMS NOTCHING AND DRILLING SHALL BE AS FOLLOWS: x �_ - � W D/ MAX o LD om 2 U I4 11 4. T\ / I--\, 0 1� ux � A RgE NIIII `� IN� �, ---Iv-- x z x a NOTCHING NOT a oU3 u / PERMITTED o L/3 L ' . 304.3. NOTCHING AND BORING OF ENGINEERED WOOD PRODUCTS IS PROHIBITED EXCEPT WHERE PERMITTED BY THE MANUFACTURER'S INSTALLATION GUIDE OR WITH PRIOR WRITTEN AUTHORIZATION FROM THE EOR. WEB HOLES IN PREFABRICATED I -JOISTS ARE PERMITTED ONLY WHERE SIZED, LOCATED, AND REINFORCED PER THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS, (SEE NOTES 104.4 AND 104.4.1). 305. ROOF FRAMING 305.1. ROOF AND ATTIC VENTILATION SHALL BE AS REQ'D BY OTHERS. REF TO IRC R806.5 FOR UNVENTED ATTIC AND ENCLOSED RAFTER ASSEMBLY REQUIREMENTS. 305.2. DIMENSIONS ON THE ROOF PLAN SHALL BE INTERPRETED AS FOLLOWS: 305.2.1. RAFTER, HIP, VALLEY, AND RIDGE LENGTHS (WHERE INDICATED) REPRESENT THE ACTUAL SLOPED MEMBER LENGTHS, ROUNDED UP TO THE NEAREST FOOT. 305.2.2. ALL OTHER DIMENSIONS REPRESENT HORIZONTAL PROJECTION LENGTHS UNLESS NOTED OTHERWISE. 305.2.3. RAFTER LENGTH FOR SPAN CHARTS SHALL BE MEASURED ALONG THE HORIZONTAL PROJECTION. 305.3. ROOF RAFTERS SHALL NOT BE SPACED FURTHER APART THAN 24" O.C. 305.4. TYPICAL RAFTER SIZE SHALL BE AS FOLLOWS: 305.4.1. ASPHALT SHINGLE OR METAL ROOF COVERING: 2X6@24"O.C. 305.4.2. TILE COVERING: 2X8 16 O.C. 305.4.3. THE ROOF FRAMING PLAN SHALL INDICATE THE ROOF COVERING MATERIAL FOR WHICH IT WAS DESIGNED. SUBSTITUTION TO A HEAVIER ROOF COVERING MATERIAL IS NOT PERMITTED WITHOUT PRIOR STRUCTURAL REVIEW AND WRITTEN APPROVAL FROM THE EOR. THE CONTRACTOR SHALL REVIEW THE DESIGN ASSEMBLY WEIGHTS OF NOTE 116.4 PRIOR TO COMMENCING CONSTRUCTION AND SHALL NOTIFY THE FOR IF ANY INTENDED MATERIAL EXCEEDS THOSE LIMITS. (SEE NOTE 116.7). 305.5. THE ENDS OF RAFTERS SHALL HAVE NOT LESS THAN 1-1/2" OF BEARING ON WOOD. 305.6. HIPS, VALLEYS, AND RIDGES SHALL BE 2-INCH NOMINAL THICKNESS MINIMUM AND SIZED TO PROVIDE FULL END -CUT BEARING FOR SUPPORTED RAFTERS. MINIMUM SIZES SHALL BE AS FOLLOWS, UNO PER PLAN: .1. ROOF PITH 12 T 11 12 - ONE DIMENSIONAL IZE LAR ER THAN ADJACENT RAFTER . 305 6 00 C 3/ 0 1 0S GS 305.6.2. ROOF PITCH 11 12 TO 16 12 - TWO DIMENSIONAL SIZES LARGER. 305.6.3. ROOF PITCH GREATER THAN 16/12 - THREE DIMENSIONAL SIZES LARGER. 305.6.4. ROOF PITCHES 3/12 AND OR LESS - HIPS, VALLEYS, AND RIDGES SHALL BE DESIGNED AS BEAMS. 305.7. ROOF RAFTERS SHALL BE NAILED TO THE TOP PLATE PER THE TYPICAL NAILING SCHEDULE (NOTE 302.8) AND SHALL BE CONNECTED TO THE TOP PLATE WITH AN H2.5 HURRICANE TIE AT EACH RAFTER, UNO. WHERE A VARIABLE PITCH CONNECTOR (VPA2 OR EQUIVALENT) IS USED AT THE RAFTER SEAT FOR OVERHANGS EXCEEDING 2'-0", THE H2.5 MAY BE OMITTED AT THAT LOCATION. HURRICANE TIE REQUIREMENTS SHALL COMPLY WITH NOTE 111. 305.8. PROVIDE PURLINS SAME SIZE AS RAFTERS THEY ARE SUPPORTING AND BRACE AT NOT MORE THAN 4'-0" O.C. TO WALL OR BEAM BELOW. PURLIN BRACE SLOPE SHALL NOT BE LESS THAN 450 FROM HORIZONTAL. PURLIN LINE SHALL BE CONNECTED TO ROOF RAFTERS AS FOLLOWS: ROOF RAFTERS (4) 3"X0.131" FACE NAILS TO RAFTER. WHERE FACE NAILS ARE ROOF SHEATHING OMITTED PROVIDE H2.5 TIE @ 48" O.C. FROM RAFTER TO BRACE PURLIN TIGHT AGAINST ROOF FRAMING. SIZE TO MATCH • ROOF RAFTERS W/ (4) 3"X0.131" NAILS EA BRACE STRONGBACK TIGHT AGAINST PURLIN o MA BRACE PER ROOF BRACE 0.PC-SCHEDULE 305.9. ROOF BRACES SHALL HAVE FULL BEARING ON TOP PLATE AND SHALL BE LOCATED WITHIN 4" FROM A STUD BELOW. CONNECT TO TOP PLATE PER TYPICAL NAILING SCHEDULE (NOTE 302.8). 305.9.1. WHERE MULTIPLE BRACES LAND AT THE SAME WALL LOCATION, PROVIDE A STUD UNDER EACH BRACE. 305.9.2. WHERE A SINGLE BRACE IS SHOWN AT RIDGE, VALLEY, OR HIP INTERSECTIONS, PROVIDE MINIMUM 1-1/2" BEARING FOR EACH SUPPORTED MEMBER - OR PROVIDE INDIVIDUAL BRACES WITHIN 12" OF THE INTERSECTION. 305.9.3. BRACE FRAMING SHALL BE SIZED PER ROOF BRACE SCHEDULE BELOW ACCORDING TO THE BRACE HEIGHT AT THE POINT OF SUPPORT ROOF BRACE SCHEDULE HEIGHT ASSEMBLY BRACE SECTION LESS THAN 8 FT 2X4 BRACE W/ 2X4 STRONGBACK 0.148"X3" @ 6" O.C. A I 8-1S FT 2X6 BRACE W/ 2X6 STRONGBACK 15-20 FT 2X8 BRACE W/ 2X8 STRONGBACK TYPICAL ROOF � STRONGBACK BRACE PER PLAN I 20-25 FT (2) 2X6 BRACE W/ 2X8 STRONGBACK BRACE 305.10. RAFTERS SHALL BE FRAMED NOT MORE THAN 1 1/2-INCHES OFFSET FROM EACH OTHER TO A RIDGE BOARD, OR DIRECTLY OPPOSITE FROM EACH OTHER WITH A COLLAR TIE, OR RIDGE STRAP. 305.11. RIDGE STRAPS OR COLLAR TIES SHALL BE INSTALLED IN THE UPPER 1/3 HEIGHT OF THE RAFTER AND SHALL NOT BE SPACED MORE THAN 4'-0" O.C. 305.11.1. COLLAR TIES SHALL BE NOT LESS THAN 1X4 NOMINAL AND INSTALLED AS FOLLOWS: RIDGE PLATE OR BEAM ROOF RAFTERS COLLAR TIE @ 48" O.C. MAX IN THE UPPER 1/3 OF RAFTER LENGTH OR WITHIN TOP 4'-0" WHICHEVER SMALLER COLLAR TIE TO RAFTER CONNECTION PER NAILING SCHEDULE 305.11.2. RIDGE STRAP SHALL BE NOT LESS THAN 1 1/4" X 20 GAUGE (CS20 BY SIMPSON STRONG TIE OR BETTER) AND SHALL BE NAILED TO THE TOP EDGE OF EACH RAFTER WITH NOT FEWER THAN (3) 10D COMMON (3"X0.148") NAILS WITH THE CLOSEST NAIL NOT CLOSER THAN 3" FROM THE END OF THE RAFTER. RIDGE BEAM RIDGE STRAP ROOF RAFTER 305.12. AT EXTERIOR WALLS, BIRDSMOUTH CUTS IN RAFTERS SHALL MAINTAIN: 305.12.1. MINIMUM 1 1/2" BEARING LENGTH OVER THE TOP PLATE 305.12.2. MINIMUM 3 1/2" RAFTER DEPTH AT THE SEAT FOR RAFTER OVERHANG 305.12.3. MINIMUM 5" HEEL HEIGHT AT EXTERIOR FACE OF WALL FRAMING 305.12.4. MAXIMUM NOTCH NOT MORE THAN 1/4 OF THE RAFTER DEPTH AT THE BEARING LOCATION 305.12.5. RAFTER OVERHANGS USING A BIRDSMOUTH CUT SHALL NOT EXCEED 2 -011 . FOR OVERHANGS EXCEEDING 2'-0", PROVIDE A VARIABLE PITCH CONNECTOR (SIMPSON VPA2 OR EQUAL) AT THE RAFTER SEAT. WHERE A VPA CONNECTOR IS USED, INSTALLATION OF AN H2.5 HURRICANE TIE MAY BE OMITTED. �'-0" MAX CANTILEVER CANTILEVER > 2'-0" (5'-0" MAX) � NO RAFTER NOTCHES ALLOWE z_y w (� in = = O ✓ �s f RAFTER, TYP VPA2 VARIABLE RAFTER, TYP ��� PITCH CONNECTOR -�- 305.13. WHERE RAFTERS ARE OVERCUT BEYOND MINIMUM REQUIRED RAFTER DEPTH AT THE BIRDSMOUTH, EACH RAFTER SHALL BE REPAIRED AS FOLLOWS: 305.13.1. AT VAULTED CEILING FRAMING: Y Q P /-\ A� . � RAFTERS PER PLAN - : � • - 3/4" PLYWOOD EACH SIDE OF RAFTER, SNUG TO T/PLATE M (3) ROWS OF 0.131"X3" NAILS @ 4" O.C. EA SIDE 305.13.2. AT FLAT CEILING FRAMING W/ LAPPED CEILING JOISTS OR BLOCKING: RAFTERS PER PLAN CEILING JOISTS PER PLAN 3/4" PLYWOOD ONE SIDE OF RAFTER. SIZE AND NAILING SIMILAR TO VAULTED OPTION (ONE SIDE ONLY) (3) ROWS OF 0.131"X3" NAILS @ 4" O.C. JOIST TO RAFTER 305.14. RAFTER SPLICES SHALL OCCUR DIRECTLY OVER SUPPORTS. PROVIDE A 4'-0" LONG SPLICE OF MATCHING MEMBER SIZE, CENTERED OVER THE SPLICE, SECURED WITH A MINIMUM OF TWELVE (12) 3" X 0.148" NAILS ON EACH SIDE OF THE SPLICE. ALTERNATIVELY LAP 24" OVER SUPPORT AND BE FACE NAILED W/ (12) 0.148" X 3" FACE NAILS. 305.15. HIP, VALLEY, AND RIDGE SPLICES SHALL OCCUR DIRECTLY OVER SUPPORTS AND BE SPLICED WITH (2) 4'4' LONG MATCHING MEMBERS CENTERED ON SPLICE, ONE EACH SIDE, FASTENED WITH (12) 0.148"X3" NAILS EACH SIDE OF SPLICE, EA FACE, AS FOLLOWS: FRAMING BUTTED UP AGAINST EACH OTHER HIP OR VALLEY BEING SPLICED (SIM AT RIDGE) 2-`J 4'-0" LONG SPLICE. NEAR SIDE AND FAR SIDE (12) 0.148"X3" EA SIDE OF SPLICE BRACE TIGHT AGAINST FRAMING BRACE OR PURLIN, AS REQ'D. SIZE PER ROOF BRACE SCHEDULE 305.16. RAFTERS SIZE 2X10 AND GREATER SHALL HAVE LATERAL BLOCKING AT BEARING POINTS AND @ 8'-0" O.C. ALONG THE LENGTH TO PREVENT ROTATION. 305.17. GABLE END WALLS SHALL HAVE SLOPED DOUBLE 2X TOP PLATES AT THE TOP OF WALL MATCHING THE SLOPE OF THE ROOF, CONSTRUCTED SIMILARLY TO STANDARD WALL FRAMING DOUBLE TOP PLATES. GABLE ROOF OVERHANGS UP TO 9" BEYOND THE WALL MAY BE FRAMED USING EXTENDED ROOF SHEATHING OVER LOOKOUT BLOCK. FOR OVERHANGS GREATER THAN 9", THE OVERHANG SHALL BE SUPPORTED BY CANTILEVERED OUTRIGGER EXTENDING BACK INTO THE ROOF STRUCTURE. OVERHAN GS LONGER THAN 2'-0" ARE NOT COVERED BY THESE STANDARD NOTES AND SHALL BE SPECIALLY DETAILED: ROOF SHEATHING CONTINUOUS F 2X OUTRIGGER @24" O.C. OVER WALL TO END OF CANTILEVER SHALL MATCH RAFTER SIZET/PROOFjjj �T/ROOF PEY R ARCH N PEE ARCH 1 A + N L IVYVI '- " MAX j 0'-9" 2 0 M MAX CANTILEVER J ti 305.18. ATTIC WALL FRAMING SHALL MEET STUD SIZE AND SPACING REQUIREMENTS PER THE EXTERIOR WALL STUD SCHEDULE (NOTE 309.9.1). A DOUBLE TOP PLATE SHALL BE PROVIDED AT THE TOP OF ATTIC WALLS. 305.19. ROOF AREAS INDICATED AS "OVERFRAMED" SHALL HAVE CONTINUOUS SHEATHING AT THE OVERFRAMED RAFTERS IN ADDITION TO ROOF SHEATHING ABOVE. AT RAFTER BEARING, A FLAT NAILER SHALL BE PROVIDED EQUAL IN SIZE TO THE LENGTH OF THE SLOPE -CUT RAFTER END. MULTIPLE 2x FLAT NAILERS ARE ACCEPTABLE. OVERFRAMING SHALL BE FRAMED AS FOLLOWS: RIDGE BOARD, TYP RAFTER TO PLATE CONNECTION PER ROOF SHEATHING, TYP TYPICAL NAILING SCHEDULE. H2.5A 000 �� NOT REQUIRED - RAFTERS AT OVERFRAMING PER PLAN (3) 0.131"X3" NAILS AT EVERY RAFTER INTERSECTION , . ,FLAT 2X NAILER PLATE WITH COLLAR TIE, TYP EDGE RIPPED TO SLOPE OF ROOF OVERFRAMING PANEL EDGE NAILING �- - _L ]_ _L ROOF FRAMING PER PLAN ROOF SHEATHING BELOW OVERFRAMING. PROVIDE VENTILATION HOLES AS REQUIRED BY OTHERS. IF ROOF SHEATHING IS OMITTED, FULL HEIGHT BLOCKING SHALL BE PROVIDED BETWEEN ROOF FRAMING @ 4'-0" O.C. THROUGHOUT THE UNSHEATHED AREA 305.20. ROOF SHEATHING SHALL BE PER NOTE 303.4. APPLY WITH THE LONG DIMENSION (STRENGTH AXIS) ACROSS SUPPORTS, CONTINUOUS OVER TWO OR MORE SPANS. PANEL JOINTS IN THE SHORT DIRECTION SHALL BE STAGGERED. NAILING PER NAILING SCHEDULE (NOTE 302.8), UNO. PROVIDE 1/8" GAP BETWEEN PANELS FOR EXPANSION. (SEE NOTES 108.4-108.6). HATCHED AREAS REPRESENT AREAS THAT ARE WITHIN 4'-0" FROM EVES, RIDGES, HIPS AND VALLEY THAT REQUIRE TIGHTER NAIL SPACING. REF 302.8 ADDITIONAL REQUIREMENTS APPLY AT SHEATHING ATTACHMENT AT GABLE END FRAMING 305.21. PRE-ENGINEERED WOOD OPEN WEB ROOF TRUSSES SHALL BE DESIGNED BY THE TRUSS MANUFACTURER PER NOTES 106.1 THROUGH 106.9. TRUSS DESIGN DRAWINGS SHALL BE SUBMITTED TO THE FOR FOR REVIEW AND APPROVAL PRIOR TO FABRICATION PER NOTE 121.3.1. 306. CEILING FRAMING 306.1. MINIMUM CEILING JOISTS SHALL BE 2X6 @ 24" O.C., UNO PER PLAN. 306.2. THE ENDS OF CEILING JOISTS SHALL HAVE NOT LESS THAN 1-1/2" OF BEARING ON WOOD. 306.3. WHERE A HANGER IS INDICATED PER PLAN, IT SHALL BE SELECTED FROM THE APPLICABLE HANGER SCHEDULE (NOTES 303.14.3 AND 303.14.4) UNLESS OTHERWISE SPECIFIED PER PLAN. ALL CONNECTOR REQUIREMENTS ARE PER NOTES 111.1 THROUGH 111.9. 306.4. CEILING JOISTS 2x10 AND LARGER SHALL HAVE EITHER A lx4 CONTINUOUS WOOD STRIP NAILED ACROSS THE TOP OF JOISTS OR SOLID BLOCKING INSTALLED AT 8'-0" O.C. MAXIMUM, AND SHALL HAVE SOLID BLOCKING AT ALL BEARING LOCATIONS, TO PREVENT ROTATION. 306.5. ENDS OF CEILING JOISTS SHALL BE LAPPED NOT LESS THAN 3" OR BUTTED OVER BEARING PARTITIONS OR BEAMS AND TOE -NAILED TO THE BEARING MEMBER. 306.6. AT EXTERIOR WALLS WHERE CEILING JOISTS REQUIRE A TAPERED END CUT TO ACCOMMODATE ROOF SLOPE, THE TAPERED END SHALL MAINTAIN A MINIMUM 5" HEEL HEIGHT AND SHALL BE FRAMED AS FOLLOWS: MAX DEPTH OF TAPER CUT, D/4, MEASURED AT INSIDE FACE OF SUPPORT CEILING JOIST, TYP I . D/4 / C % z - _ � DEPTH, D T/ PL L Lu w PE� Ln _ _ -� JOIST DEPTH AT TAPER CUT 306.7. ALL EXTERIOR WALLS SHALL BE BRACED AT TOP BY ROOF, CEILING OR FLOOR FRAMING. 306.7.1. WHERE AT LEAST ONE SIDE OF THE WALL HAS CEILING OR FLOOR FRAMING PERPENDICULAR TO THE TOP PLATE, SEE NAILING SCHEDULE (NOTE 302.8) FOR THE REQUIRED JOIST -TO -WALL CONNECTION. 306.7.2. WHERE FRAMING IS PARALLEL TO THE TOP PLATE, PERPENDICULAR BLOCKING SHALL BE PROVIDED AT 2'-0" O.C. MAXIMUM TO BRACE THE TOP OF WALL: AT HIP ROOF: RAFTERS PER PLAN BLOCKING TO MATCH CEILING JOIST SIZE (3) 0.131"73" FACE NAILS CEILING JOISTS PER PLAN BLOCKING TO RAFTERS _ (3) 0.131"X3" END NAILS _ TYP CEILING JOIST TO TOP PLATE CONNECTION v/� EAf , I I PER NAILING SCHEDULE 1► 0 AT LOW SLOPED ROOF, WHEN DISTANCE "D" EXCEEDS JOIST SPACING, PROVIDE SECOND JOIST AT BLOCKING ATTACHMENT AT GABLE END: '47 _iu. GABLE END WALL STUDS T/ PL 1 � PE� R ARCH - - SIM TO ABOVE. BLOCKING SPACING TO --t- MATCH GABLE END STUD SPACING 306.8. AT RAISED (TRAY OR BOX) CEILING LOCATIONS INDICATED ON ARCHITECTURAL PLANS, WHERE THE RAISED CEILING FRAMING AND ROOF FRAMING OVERLAP, FRAMING SHALL BE AS FOLLOWS: 306.8.1. CEILING JOISTS: RAFTERS PER PLAN 7-;7\ (6) 0.131" X 3" FACE CEILING JOISTS PER PLAN KNEE BRACE TO MATCH RAFTER SIZE. CUT SNUG TO CEILING JOISTS AND TOP PLATE WALL BELOW fNAILS JOIST TO RAFTER (2) ROWS OF 0.131" X 3" @ 4" O.C. FACE NAILS \\RAFTER TO KNEE BRACE 1 _. - . .. - . Ll� � ]:;: f �4 vv -.- a * I ALIAKSEI wA EVICH .............................. ',, s 130521 f 4 • �Oc �•'•7/OENSE�•'�'r �,,SS%'••........• GX� N 1 O E ONAL AL w 0 Z O� (9 _ D Z 0 �-Wtad 0 WLW Z W Z_ Z2 00W J M m 2: IT o O O'� ko U ` n U x Z 2: 0� fY LLJ LL- z W Z , W a Z W X � O (D rsi �_ .--i J NI _ ,--I U X O w m Ln Q L 0- m ,--1 00 fV i Ln [V LD REVISIONS 0 DATE BY PROJECT NAME 101 CROSS CREEK GARAGE ADDITION PROJECT ADDRESS 101 CROSS CREEK DR GRAPEVINE, TX PROJECT NUMBER S26129 CHECKED BY - AP SHEET DATE - 05/04/2026 SCALE 24X36 SHEET:1/2"=1'-0" Z _O t Ln W 0 J !`I F_ 11-1 z Q Lu O z Z p--1 z 9 LL --A O I U) rCEILING JOISTS PER PLAN f T/PL @ HIGH CEILING PER ARCH r G N 301. GENERAL FRAMING NOTES, TYP METAL SUPPORTS, OR LESS THAN 3" AT CONCRETE OR MASONRY SUPPORTS. FOR ADDITIONAL BEAM AND JOIST BEARING, FRAMING NOTATION, LOAD PATH, CONNECTOR, AND MULTI -PLY BEAM REQUIREMENTS, DETAILS AND SCHEDULES CONTINUED SEE NOTES 303.6 THROUGH 303.13. 307.4. FULL -DEPTH BLOCKING, RIM BOARD, OR A PERPENDICULAR BEAM SHALL BE PROVIDED AT ENDS OF 306.8.2. MULTI -PLY SAWN LUMBER 2X CEILING BEAM OVERLAP: FLOOR JOISTS AND AT POINTS OF VERTICAL SUPPORT FOR MULTI -SPAN JOISTS TO PREVENT ROTATION RAFTERS PER PLAN. MIN (2) EA SIDE OF (6) 0.131" X 3" FACE NAILS AND MAINTAIN LATERAL STABILITY. BEAM. NAIL RAFTERS TO EACH OTHER W/ FIRST RAFTER TO BEAM, BOTH 307.5. FULL -DEPTH BLOCKING PROVIDED AT INTERMEDIATE SPAN LOCATIONS SHALL MATCH THE DEPTH OF 0.131"X3" FACE NAILS @ 4" O.C. STAGGERED SIDES OF BEAM ADJACENT FLOOR FRAMING, BE INSTALLED PERPENDICULAR TO THE JOISTS, AND BE FASTENED TO EACH ADJACENT JOIST WITH A MINIMUM OF 2 0.131„ X 3„ NAILS. BLOCKING SHALL BE INSTALLED AS BEAM PER PLAN (2) ROWS OF 0.131" X 3" @ 4' ( ) O.C. FACE NAILS FIRST RAFTER FOLLOWS: KNEE BRACE UNDER BEAM TO MATCH O. KNEE BRACE 307.5.1. 2X FLOOR FRAMING: TO RAFTER SIZE AND OVERALL BEAM WIDTH \ ' • / FLOOR FRAMING PER PLAN STUDS BELOW TO MATCH OVERALL WIDTH ` FULL HEIGHT BLOCKING OF BEAM -RAFTER ASSEMBLY ABOVE 4WL � ISO RAFTERS PER PLAN -- (6) 0.131" X 3" FACE NAILS FIRST RAFTER TO BEAM, BOTH BEAM PER PLAN SIDES OF BEAM (2) ROWS OF 0.131" X 3" @ 3" O.C. FACE KNEE BRACE TO MATCH RAFTER NAILS FIRST RAFTER TO KNEE BRACE �SIZE. CUT SNUG TO CEILING JOISTS AND TOP PLATE ELEVATION 306.9. AT RAISED (TRAY OR BOX) CEILING WITHIN INTERIOR SPACES, CEILING JOISTS AND BEAMS SHALL CONTINUE TO T/WALL AND TRAY SHALL BE FRAMED AS FOLLOWS: 306.9.1. W/DOUBLE TOP PLATE AT WALLS W/ LOW CEILING ON THE OPPOSITE SIDE OF THE WALL: CEILING JOISTS OR BEAM PER \• PLAN. CONTINUOUS TO WALL �- TOP PLATE AT CEILING JOISTS CEILING JOISTS AT LOW CEILING (3) 0.131 X3, FACE NAILS AT L� �r KNEE BRACE TOP AND BOT TOP PLATE AT T/ WALL. 306.9.2. W/ CONTINUOUS STUDS TO T/ TRAY CEILING: CEILING JOISTS OR BEAM PER \• -- PLAN. CONTINUOUS TO WALL \ TOP PLATE AT CEILING JOISTS \ _ (3) 0.131"X3" FACE NAILS TOP 2X6 NAILER AT WALL W 3 0,131" X 3" NAILS EA STUD (3) 0.131"X3" TOE NAILS AT KNEE BRACE TO NAILER 306.9.3. A DOUBLE TOP PLATE SHALL NOT BE PROVIDED AT AN INTERMEDIATE HEIGHT IN THE WALL UNLESS THE PLATE IS BRACED BY A CEILING DIAPHRAGM ON AT LEAST ONE SIDE OF THE WALL. FRAMING FOR A TRAY OR BOX CEILING SHALL NOT BE CONSIDERED AS BRACING FOR AN INTERMEDIATE TOP PLATE UNLESS SPECIFICALLY DETAILED AS SUCH ON THE STRUCTURAL DRAWINGS. 306.10. WHERE A CEILING BEAM DEPTH IS AT LEAST 1.5x THE DEPTH OF ADJACENT CEILING JOISTS, OR EXCEEDS 12" IN DEPTH, LATERAL BRACING SHALL BE PROVIDED AT THE TOP OF THE BEAM TO PREVENT ROTATION. BRACES SHALL BE AT MAXIMUM 8'-0" O.C. ON OPPOSITE SIDES OF THE BEAM WHERE SPACE PERMITS: (3) 3"X0.131" TOE NAILS 2X4 KNEE BRACE @ 8'-0" O.C. 2X STRONG BACK AT AT PERPENDICULAR FRAMING 2 PARALLEL FRAMING (3) 3"X0.131" FACE NAILS 1 I PEYPL T/ R ARCH CEILING JOIST HANGER, TYP BEAM 306.11, AT INTERIOR WALLS WHERE CEILING HEIGHT IS NOT EQUAL ON BOTH SIDES OF THE WALL, A FRAMING BRACE SHALL BE PROVIDED @ 48" O.C. AS FOLLOWS: (4) 0.131" X 3" FACE NAILS TOP AND BOT OF BRACE 2X4 KNEE BRACE @ 4'-0" O.C. 1 1� j CRIPPLE STUDS SISTERED TO LOW CEILING JOISTS TO MATCH T/PL @ LOW CEILING ! SIZE OF WALL BELOW PER ARCH (4) 0.131" X 3" FACE NAILS CEILING JOISTS PER PLAN AT OVERLAP 306.12. AT EXTERIOR WALLS WHERE THE TOP PLATE AT ROOF IS HIGHER THAN THE TOP PLATE FOR INTERIOR CEILING HEIGHT, A KNEE BRACE SHALL BE PROVIDED AT MAXIMUM 4'4" O.C., SLOPED APPROXIMATELY 1:1 DOWN TO CEILING FRAMING: 306.12.1. AT PERPENDICULAR CEILING FRAMING: ROOF FRAMING PER PLAN (4) 0.131"X3" FACE NAILS AT KICKER TOP 2X4 KICKER @ 4'-0" O.C. T/ PL (4) 0.131"X3" TOE NAILS BOT, (2) EA SIDE PER CONTINUOUS 2X6 NAILER WITH 2X6 STRONGBACK ; 0.131"X3" @ 6" O.C. NAILER TO STRONGBACK, TYP 6" MAX T/ PL PER (2) 0.131"X3" FACE NAILS STRONGBACK TO EA JOIST CEILING FRAMING PER PLAN CRIPPLE STUDS SISTERED TO CEILING JOISTS (4) 0.131"X3" FACE NAILS JOIST TO CRIPPLE STUD 306.12.2. AT PARALLEL CEILING FRAMING: ROOF FRAMING PER PLAN (4) 0.131"X3" FACE NAILS NAILER TO BLOCKING 2X4 KICKER @ 4' 0" O.C. T� (4) 0.131"X3" FACE NAILS AT KICKER TOP AND BOT PERaR H 4'-0" 2X6 NAILER WITH 2X6 STRONGBACK TO MATCH KICKER SPACING (2) 0.131"X3" EVERY CEILING JOIST T/ PLC� PERPERARCHC CEILING FRAMING PER PLAN BLOCKING 307. FLOOR FRAMING 307.1. FLOOR FRAMING SHALL BE CONTINUOUS BETWEEN POINTS OF VERTICAL SUPPORT AS INDICATED ON PLAN. SPLICING IS NOT ALLOWED WHERE MEMBERS ARE NOT DIRECTLY SUPPORTED BELOW. CANTILEVERED FRAMING SHALL NOT BE SPLICED. MEMBERS DESIGNATED "CONT," "CONTINUOUS," "2-SPAN," "3-SPAN," OR SIMILAR SHALL BE INSTALLED CONTINUOUS OVER MULTIPLE SUPPORTS WITHOUT SPLICES. 307.2. FLOOR JOISTS SHALL HAVE FULL BEARING ON TOP PLATES. JOISTS FRAMING FROM OPPOSITE SIDES OVER A BEARING SUPPORT SHALL LAP NOT LESS THAN 3" AND BE NAILED TO TOP PLATE PER TYPICAL NAILING SCHEDULE (NOTE 302.8). 307.3. FLOOR BEAMS SHALL HAVE FULL BEARING ON TOP PLATES, WHERE BEAMS OCCUR IN LINE ON OPPOSITE SIDES OF A WALL, EACH SHALL HAVE 1/2 PLATE WIDTH FOR BEARING, LINO PER PLAN. AT PERIMETER WALLS, FLOOR FRAMING SHALL HAVE FULL BEARING EXCLUDING RIM BOARD WHERE APPLICABLE. UNDER NO CIRCUMSTANCES SHALL FLOOR JOISTS, BEAMS, OR GIRDERS BEAR LESS THAN 1-1/2" AT WOOD OR 307.5.2. ENGINEERED WOOD I -JOISTS: (2) FACE NAILS FROM JOISTS INTO BLOCKING FLOOR FRAMING PER PLAN FULL HEIGHT BLOCKING 2X4 NAILER EA SIDE W/(2) FACE NAILS FROM JOISTS WEB INTO NAILER AND (2) FACE NAILS FROM BLOCKING WEB INTO NAILER. (NAILER NOT REQUIRED AT BEARING WALL BELOW) 307.6. FULL -DEPTH BLOCKING SHALL BE PROVIDED UNDER PERPENDICULAR LOAD -BEARING WALLS ABOVE AND OVER LOAD -BEARING WALLS BELOW TO ENSURE PROPER LOAD TRANSFER AND LATERAL STABILITY. REFER TO SHEAR WALL SCHEDULE (NOTE 409) FOR ADDITIONAL REQUIREMENTS AT SHEAR WALLS. CONNECTION PER TYPICAL NAILING SCHEDULE (OR PER SHEARWALL SCHEDULE IF SHEARWALL ABOVE) FULL HEIGHT BLOCKING FLOOR FRAMING�� PER ARCH PEER ARCH , CONNECTION PER TYPICAL FLOOR FRAMING NAILING SCHEDULE (OR PER FULL HEIGHT BLOCKING SHEARWALL SCHEDULE IF SHEARWALL BELOW) 307.7. TYPICAL FLOOR FRAMING DETAILS (WALLS ABOVE NOT SHOWN FOR CLARITY): 307.7.1. PARALLEL FRAMING AT EXTERIOR WALL: NAILING INTO RIM PER TYPICAL NAILING SCHEDULE RIM TO BLKG SIM TO RIM TO END OF JOISTS PER TYP NAILING SCHEDULE �T/ FLFR FLOOR SHEATHING PERARCHY RIM BOARD FLOOR FRAMING PARALLEL TO WALL BLOCKING @ 24" O.C. BLOCKING TO JOIST ATTACHMENT PER SECTION 72.2 BLOCKING TO TOP PLATE ATTACHMENT PER TYPICAL NAILING SCHEDULE TOE NAIL AT RIM PER TYPICAL NAILING SCHEDULE 307.7.2. PARALLEL FRAMING AT INTERIOR WALL (NON -BEARING, NON-SHEARWALL): T/ FLFR PER ARCH INTERIOR NON -LOAD BEARING WALLS SHALL BE-,,," BRACED AT TOP BY CEILING DIAPHRAGM VIA NAILER ATTACHMENT TO THE TOP OF THE WALL �< umo 307.7.3. PARALLEL FRAMING AT INTERIOR WALL (BEARING, AND/ OR SHEARWALL): NAILING INTO FRAMING BELOW PER TYPICAL NAILING SCHEDULE (OR SHEARWALL SCHEDULE AT SHEARWALLS) (3) 0.131"X3" SHEATHING TO BLOCKING T/FLFR,� FLOOR SHEATHING �r � PER AR CH JOIST OR LSL/LVL (REF SHEARWALL SCHEDULE) FLOOR FRAMING PARALLEL TO WALL BLOCKING @ 24" O.C. rs'• BLOCKING TO JOIST ATTACHMENT PER SECTION 72.2 BLOCKING TO TOP PLATE ATTACHMENT PER TYPICAL NAILING SCHEDULE CONNECTION PER TYPICAL NAILING SCHEDULE (OR SHEARWALL SCHEDULE AT SHEARWALLS) 307.7.4, PERPENDICULAR FRAMING AT INTERIOR AND EXTERIOR WALLS: NAILING INTO BLOCKING PER NAILING INTO RIM PER TYPICAL TYPICAL NAILING SCHEDULE NAILING SCHEDULE FULL HEIGHT BLOCKING FLOOR SHEATHING RIM BOARD FLOOR SHEATHING 1 T/ FLFR FLOOR FRAMING FLOOR FRAMING PER ARCH PERPENDICULAR TO WALL PERPENDICULAR TO WALL FLANGE NAIL AT ENGINEERED I -JOIST FRAMING TO TOP PLATE (OR TOE NAIL AT SOLID BLOCKING) ATTACHMENT PER TYPICAL PER TYPICAL NAILING SCHEDULE NAILING SCHEDULE FRAMING TO TOP PLATE ATTACHMENT TOE NAIL AT RIM PER PER TYPICAL NAILING SCHEDULE TYPICAL NAILING SCHEDULE INTERIOR EXTERIOR 307.8. FLOOR SHEATHING SHALL BE PER NOTE 303.4. APPLY WITH THE LONG DIMENSION (STRENGTH AXIS) ACROSS SUPPORTS, CONTINUOUS OVER TWO OR MORE SPANS. PANEL JOINTS IN THE SHORT DIRECTION SHALL BE STAGGERED, FLOOR SHEATHING SHALL BE GLUED AND NAILED. NAILING PER NAILING SCHEDULE (NOTE 302.8), UNO PER SHEAR WALL SCHEDULE (NOTE 409). ADHESIVES SHALL MEET APA SPECIFICATION AFG-01 OR ASTM D3498 AND BE APPLIED PER MANUFACTURER'S RECOMMENDATIONS. (SEE NOTES 108.4-108.8). 307.9. WHERE A HANGER IS INDICATED PER PLAN, IT SHALL BE SELECTED FROM THE APPLICABLE HANGER SCHEDULE (NOTES 303.14.3 AND 303.14.4) UNLESS OTHERWISE SPECIFIED PER PLAN. 307.10. PROVIDE WEB STIFFENERS AT ENGINEERED WOOD I -JOISTS WHERE INDICATED ON PLANS OR DETAILS, INSTALLED PER MANUFACTURER REQUIREMENTS. WEB STIFFENER AT TJI JOISTS SHALL BE AS FOLLOWS: GAP: 1/8" MIN, 2 3/4" MAX WEB STIFFENER SCHEDULE TJI SERIES WEB STIFFENER NAILS _ NAILS PER SCHEDULE. CLINCH AS REQ'D 210 3/4" X 2 5/16" (') (3) 0.131" X 21/2" WEB STIFFENER PER SCHEDULE, BOTH SIDES 2301,111 7/8" X 2 5/16" (') (3) 0.131" X 2 1/2" 560 2X4 (`) (3) 0.162" X 3 1/2" _ TIGHT FIT TO BOTTOM FLANGE NOTES: �+ (1) P51 OR P52 SHEATHING, FACE GRAIN VERTICAL (2) #3 GRADE OR BETTER 307.11. PROVIDE VERTICAL CRUSH BLOCKING (V.C.B.) WITHIN FLOOR FRAMING WHERE POSTS OR BUNDLED STUDS ABOVE ALIGN WITH WALLS BELOW; BLOCKING SHALL MATCH OR EXCEED THE SIZE OF SUPPORTED MEMBERS AND EXTEND FULL FLOOR DEPTH, SNUG TOP AND BOTTOM: POST OR BUNDLED STUDS ABOVE T/FLR FRAMING VERTICAL CRUSH BLOCKING (VCB) PER ARCH WIDTH OF BLOCKING MATCH OR EXCEED WIDTH OF POST OR BUNDLED STUDS ABOVE ( r/ PL j PER ARCH POST OR BUNDLED STUDS BELOW 307.12. PRE-ENGINEERED WOOD OPEN WEB FLOOR TRUSSES SHALL BE DESIGNED BY THE TRUSS MANUFACTURER PER NOTES 106.1 THROUGH 106.9. TRUSS DESIGN DRAWINGS SHALL BE SUBMITTED TO THE FOR FOR REVIEW AND APPROVAL PRIOR TO FABRICATION PER NOTE 121.3.1. 308. DECKS 308.1. WOOD -FRAMED DECKS EXPOSED TO WEATHER SHALL BE CONSTRUCTED WITH DECAY -RESISTANT OR PRESERVATIVE -TREATED FRAMING PER NOTE 103.5. ALL FASTENERS AND CONNECTORS SHALL MEET THE CORROSION PROTECTION REQUIREMENTS OF NOTES 110.3 AND 111.3 FOR EXTERIOR AND TREATED WOOD APPLICATIONS. 308.2. THE WEATHER BARRIER AT EXTERIOR WALLS SHALL BE CONTINUOUS THROUGH DECK FRAMING. PROVIDE FLASHING AS REQUIRED. WATERPROOFING, FLASHING, AND SEALANTS ARE NOT INCLUDED IN THE STRUCTURAL SCOPE AND SHALL BE DESIGNED BY OTHERS. (SEE NOTE 126.1.) 308.3. RIM BOARD AT DECK CONNECTION SHALL BE A MINIMUM 1 1/2" THICK, LINO. 308.4. FOR TYPICAL LOADING CONDITIONS (10 PSF DL, 40 PSF LL), DECK LEDGER SHALL BE CONNECTED TO RIM BOARD PER THE DECK LEDGER CONNECTION SCHEDULE BELOW: LEDGER CONNECTION OPTIONAL 1/2" 1" MAX RIGID PER SCHEDULE GAP W/STACKED FOAM BOARD WASHERS FASTENERS SHALL BE VERTICALLY OFFSET BETWEEN ROWS DECK LEDGER CONNECTION SCHEDULE FOR IOPSF DL, 40 PSF LL... MAX DECK JOISTS SPAN MIN VERTICAL PER FASTENER 641. ` JJ l DISTANCEALLOWABLE FASTENER TYPE FROM MAXIMO.C.ISPACINIG OF FASTENERS TOP M LEDGER BETWEEN SHEAR LOAD UM ANDBOT"") ROWS (LBS) SDWS224000DB 14" 8" 6" 5" 6" 4" 265 SDWS2740055 13" 8" 6" 4" 6" 4" 235 SDWH1940ODB 13" 8" 5" 4" 6" 4" 225 SDWH2740OG 22" 13" 10" 7" 6" 4" 280 SDWH2740OSS 19" 11" 8" 6" 3" 11/2' 235 SDWH19400SS 14" 11" 6" 5" 3" 11/2 ' 177 SDS25312 13" 8" 5" 4" 4" 3" 165 MAXIMUM O.C. SPACING OF FASTENERS TOP AND BOT WITH 112" GAP (2)(3} SDWH1940ODB 13" I 8" I 5" I 4" 6" 4" 245 MAXIMUM O.C. SPACING OF FASTENERS TOP AND BOT WITH 1" RIGID FOAM BOARD (2'(3) SDWH274DOG 12" I 7" I 5" I 4" 6" 4" I) NOT APPLICABLE FOR DECKS W/ CONC TOPPING OR HEAVY TILE SYSTEMS. 2) AT LEDGERS 10" TO 16" TALL ADD ANOTHER ROW OF FASTENERS IN THE MIDDLE OF LEDGER. 3) AT LEDGERS 16" TO 22" TALL ADD TWO ROWS OF FASTENERS IN THE MIDDLE SPACED AT 6" MAX O.C. VERTICALLY. 309, WALL FRAMING 309.1. STUDS SHALL BE CONTINUOUS BETWEEN THE SILL (SOLE, BOTTOM) PLATE AND THE TOP PLATE TO RESIST LOADS PERPENDICULAR TO THE WALL. CONNECTIONS PER NAILING SCHEDULE (NOTE 302.8). SUPPORTS SHALL BE FOUNDATION, FLOOR, CEILING, OR ROOF DIAPHRAGM, EXCEPTION: JACK AND CRIPPLE STUDS AT OPENINGS. 309.2. STUDS SHALL BE INSTALLED WITH THE WIDE FACE PERPENDICULAR TO THE WALL LINE, WITH SHEATHING AND DRYWALL ATTACHED TO THE NARROW FACE. 309.3. STUD WALLS SHALL BE CAPPED WITH A DOUBLE TOP PLATE HAVING A WIDTH AT LEAST EQUAL TO THE STUD WIDTH, PROVIDING OVERLAPPING AT CORNERS AND INTERSECTIONS WITH BEARING PARTITIONS. END JOINTS IN A CONTINUOUS TOP PLATE SHALL BE OFFSET AT LEAST 2'-0", LINO. TOP PLATE CONTINUITY, SPLICING, AND CONNECTION REQUIREMENTS SHALL BE AS FOLLOWS: 309.3.1. TYPICAL LAP SPLICE: LAP SPLICE (MIN 2'- PIQ") T/ PLIRCH T/PL TO T/PL NAILING PER TYPICAL NAILING SCHEDULE PLATE JOINT NAILING AT T/PL SPLICE PER TYPICAL NAILING SCHEDULE a I PLATE JOINT 309.3.2. TYPICAL CORNER JOINT: PERPENDICULAR WALL FRAMING LAPPED AND ATTACHED PER TYPICAL NAILING SCHEDULE ONE TOP PLATE SHALL BE CONTINUOUS THROUGH JOINT WALL FRAMING PER PLAN 309.3.3. WHERE A CONTINUOUS EXTERIOR WALL OR INTERIOR SHEAR WALL TRANSITIONS TO A DIFFERENT WALL THICKNESS AND A STANDARD TOP PLATE LAP SPLICE CANNOT BE ACHIEVED, PROVIDE A CS16XT-0" STRAP CENTERED OVER THE SPLICE AND FASTENED WITH (22) 0.131"X2 1/2" NAILS EACH SIDE OF SPLICE. PERPENDICULAR WALL FRAMING LAPPED AND ATTACHED PER TYPICAL NAILING SCHEDULE WALL FRAMING PER PLAN BOTH TOP PLATES ARE TERMINATED AT WALL THICKNESS TRANSITION CS16 X T-0" CENTERED ON SPLICE 309.3.4. TOP PLATES MAYBE OMITTED OVER A HEADER OR BEAM WHERE THE HEADER OR BEAM IS CONNECTED TO THE ADJACENT TOP PLATES ON EACH SIDE WITH A CS16 x 3'-0" STRAP CENTERED AT THE JOINT AND FASTENED WITH (22) 0.131"X2 1/2" NAILS EACH SIDE OF JOINT, UNO: --WALL FRAMING PER PLAN -CS16 X T-0" CENTERED ON SPLICE ABEAM OR HEADER PER PLAN 309.3.5. A SINGLE TOP PLATE IS PERMITTED OVER A HEADER PROVIDED THAT: 309.3.5.1. THE TOP PLATE LAPS THE HEADER BY THE MINIMUM REQUIRED LAP DISTANCE AND IS NAILED TO THE HEADER PER THE TYPICAL NAILING SCHEDULE TOP PLATE LAP SPLICE. 309.3.5.2. THE TOP PLATE CONTINUING PAST THE HEADER SHALL LAP AND CONNECT TO THE ADJACENT DOUBLE TOP PLATE BY THE MINIMUM REQUIRED LAP DISTANCE AND NAILING PER THE TYPICAL NAILING SCHEDULE TOP PLATE LAP SPLICE. i-� CONTINUOUS TOP PLATE WITH LAP DISTANCE AND CONNECTION TO ADJACENT TOP PLATE AS REQUIRED FOR LAP SPLICE WALL FRAMING PER PLAN SINGLE TOP PLATE CONTINUOUS OVER THE BEAM AT TOP PLATE SPLICES OVER BEAMS, PROVIDE A MINIMUM T-0" LAP LENGTH EACH SIDE OF SPLICE AND FASTEN WITH (12) 0.131"X3" SHALL PER SIDE BEAM OR HEADER PER PLAN 309.3.6. WHERE PIPING OR DUCTWORK REQUIRES DRILLING OR NOTCHING OF THE TOP PLATE BY MORE THAN 50%, PROVIDE A GALVANIZED METAL TIE 16 GAx 1-1/2' WIDE FASTENED ACROSS THE NOTCH WITH MINIMUM (10) 0.148"x3-1/4" NAILS EACH SIDE (MSTC28 OR (2) CS16x2'-6" MINIMUM). MINIMUM 1-1/2" WIDTH OF TOP PLATE SHALL REMAIN AT NOTCH: " PENETRATION REQUIRING MORE THAN 50 PERCENT NOTCH IN TOP PLATES TOP PLATES WALL FRAMING PER PLAN MSTC28 CENTERED ON SPLICE (ALT (2) CS16 X 2'4") 309.4. WOOD STUDS SHALL HAVE FULL BEARING ON A NOMINAL 2X SILL PLATE (OR 3X WHERE REQUIRED BY SHEAR WALL SCHEDULE (NOTE 409)) HAVING A WIDTH NOT LESS THAN THE STUD WIDTH, UNLESS NOTED OTHERWISE. 309.4.1. DOUBLE SILL PLATE IS REQUIRED AT PORTAL FRAMES. REF NOTE 412. 309.5. SILL PLATES SHALL BE ATTACHED TO WOOD FRAMING BELOW PER NAILING SCHEDULE (NOTE 302.8). SEE SHEAR WALL SCHEDULE (NOTE 409) FOR NAILING REQUIREMENTS AT SHEAR WALL LOCATIONS. 309.6. SILL PLATES SHALL BE ANCHORED TO CONCRETE PER THE SILL PLATE ANCHOR SCHEDULE BELOW, UNO. SEE SHEAR WALL SCHEDULE (NOTE 409) FOR ANCHOR REQUIREMENTS AT SHEAR WALL LOCATIONS: 309.6.1. FOR EXTERIOR WALLS 10'-0" IN HEIGHT OR LESS, AND FOR ALL INTERIOR WALLS; SILL PLATE ANCHOR SCHEDULE ('X3Xs) MAXIMUM O.C. SPACING OF FASTENERS MINIMUM EDGE FASTENER TYPE MIN CONC THICKNESS DISTANCE EXTERIOR WALLS INTERIOR WALLS 1/2' 0 CAST IN PLACE A.B (2) 6'-0" 6-0" 1'-0" 2" PDPAWL-287MG 11-10" 4'-0" 4" 2" 1/2"X6" TITEN HD (4) 6 4' 6-0" 8" 2" MASH 6'-0" 8" - 1) AT NON SHEARWALLS. FOR SHEARWALL ANCHORAGE REFER TO SHEARWALL SCHEDULE. 2) 1/2" 0 ANCHOR BOLTS SHALL HAVE MIN 7" CONCRETE EMBEDMENT. SHALL BE SET IN PLACE BEFORE POUR OR PLACED WHEN CONCRETE IS STILL PLASTIC. CONCRETE SHALL BE VIBRATED AROUND ANCHOR BOLTS TO ENSURE CONTACT BETWEEN ANCHORS AND CONCRETE. PROVIDE STANDARD NUT AND WASHER. 3) 10'-0" MAX EXTERIOR WALL HEIGHT. FOR TALLER WALLS, REFER TO SILL PLATE ANCHORAGE TO CONCRETE AT TALL WALLS SCHEDULE. 4) MECHANICALLY GALVANIZED OR STAINLESS STEEL. 5) PROVIDE MINIMUM (2) ANCHORS PER PLATE, WITH ONE ANCHOR LOCATED WITHIN 12" BUT NOT LESS THAN 4" FROM EACH END OF THE PLATE SECTION. 309.6.2. FOR EXTERIOR WALLS GREATER THAN 10'-0" AND UP TO 24'-0" 1N HEIGHT SILL PLATE ANCHOR SCHEDULE AT TALL WALL5('X2) EXTERIOR WALL HEIGHT f3j FASTENER TYPE 12'-0" I 14'-0" I 16"4" I 18'4" I 20'4' I 22'-0" I 24'-W MAXIMUM O.C. SPACING OF FASTENERS 1/2" 0 CAST 1N PLACE A.B. 5'-0" 4'-D" T-6" T-3" 3'4' 2'.9" 2'4" 1/2"X6" TITEN HD (4) 5'-0" 4'-0" T-6" 3'-3" T-O" 2'.9" 2'-6" 5/8"X6" TITEN HD (4X5) V-0" V-0" 5'-0" 4'-6" 4'-0" T-9" T-6" 1) MIN CONC THICKNESS AND MIN EDGE DISTANCE SIM TO SILL PLATE ANCHORAGE TO CONCRETE SCHEDULE 2) FOR SHEARWALL ANCHORAGE REFER TO SHEARWALL SCHEDULE. 3) EXTERIOR WALL HEIGHT OF CONTINUOUS WALL STUDS FROM FOUNDATION TO THE NEAREST POINT OF LATERAL SUPPORT (CEILING, ROOF OR FLOOR DIAPHRAGM). 4) MECHANICALLY GALVANIZED OR STAINLESS STEEL. 5) CONC THICKNESS AND MIN EDGE DISTANCE SIM TO 1/2"X6" TITEN HD 309.7. INTERIOR WALLS SHALL BE SHEATHED ON AT LEAST ONE SIDE (DRYWALL ACCEPTABLE) OR PROVIDED WITH BLOCKING AT 4'-0" O.C. VERTICALLY. 309.8. EXTERIOR WALLS SHALL BE SHEATHED FULL HEIGHT WITH MINIMUM 1/2" GYPSUM BOARD AT THE INTERIOR AND WOOD STRUCTURAL PANEL SHEATHING AT THE EXTERIOR PER NOTE 303.4. 309.9. AT SHEAR WALL LOCATIONS, ALL VERTICAL PANEL JOINTS SHALL OCCUR OVER STUDS AND ALL HORIZONTAL PANEL JOINTS SHALL OCCUR OVER HORIZONTAL BLOCKING. 309.10. STUD SIZE SHALL BE BASED ON WALL HEIGHT, THICKNESS, AND FINISHES AS SHOWN ON THE ARCHITECTURAL DRAWINGS AND SELECTED PER THE WALL STUD SCHEDULES BELOW, UNO PER PLAN. DEFLECTION LIMITS PER NOTE 118.1.6 SHALL APPLY. 309.10.1. EXTERIOR WALL STUD SCHEDULE: EXTERIOR WALL STUD SCHEDULE - SYP, WIND -I IOMPH, EXP "B" MAX LATERALLY UNSUPPORTED STUD HEIGHT('X4)(5)(7) EXT WALL W/STUCCO OR EXT WALL W/ BRICK VENEER EXT WALL W/ FLEXIBLE PLASTER COVERING COVERING 2) COVERING STUD SIZE AND SPACING GRADE SUPPORTING ONE TWO ONE TWO ONE TWO ROOF + FLOOR + --LOORS + ROOF + FLOOR + FLOORS + ROOF + FLOOR + --LOORS + F+ + F+ F+ F+ F+ CEILING R00 ROOF CEILING R00 R00 CEILING R00 R00 CEILING CEILING CEILING CEILING CEILING CEILING ZX4 @ 24" O.C. STUD 10' 0" 10, 0" 10, 0" #2 10'-01, 1D'-O" - 2X4 @ 16" O.C. STUD 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" #2 11'-0" 101-0" 11'-o" 10'-0" 11'-0" 10'-0" 2X4 @ 12" O.C. STUD 10'-0" 10'-0" 1D'-O" 10'-0" 10'-0" " 10'-0 #2 12'-0" 10%0" 12'-0" 10'-0" 12'-0" 10'-0" 2X6 @ 24" O.C. STUD 10'-0" 10'-0" 10'-0" " " 10'-0" 10'-010'-0 #2 IT-3" 12'-3" 10'-0' 15'-3" 12'-3" 10'-0" 16-0" 12'-3" 10'-0' STUD 10'-0" 10'-0" 10'-0" 10'-C" IT-o" 10'-0" 10'-0" 10'-0" 10'-0" 2X6 @ 16" O.C. k2 15'-3" 14'-9" 13'-0" 17'-6" 15'-6" 13'-0" 19'-3" 15'-6" 13'-0" STUD 10'-0" 10'-0" 10'-0" 10'-W 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 2X6 @ 12" O.C. #2 16'-9" 16'-6" 15'-3" 19'-3" 18'-3" 15'-3" 21'-3" I8'-3" 15'-3" DOUBLE 2X6 016" O.C.(6) #2 19'-3" 19'-3" 1T-0" 22%3" 22'-0" 19'-3" 23'-3" 22'-6" 1T-3" DOUBLE 2X6 012" O.C.(6) #2 21'-6" 21'-3" 21'-0" 23'-3" 23'-3" 22'-6" 23'-3" 23'-3" 22'-6" 2X8 @ 16" O.C. #2 20'-3" 20'-0" 18'-9" 23'-3" 22'-3" 18'-9" 24'-0" 22'-0" 18'-9" 2X8 @ 12" O.C. #2 22'-6" 22'-3" 22'-0" 24%0" 24'-0" 22'-C" 24'-0" 24'-0" 22'-0" 1-1/2"X5-1/2"@ 16" 0-C. LSL 1.3E 14'-9" 14'-6" 14'-3" 17'-0" 16'-9" 16'-6" 18'-9" 18'-6" 17'-9" 1-1/2"X5-1/2"@ 12" O.C. LSL 1.3E 16'-3" 16%0" 15'-9" 18'-9" 18'-6" 18'-3" 20'-9" 20'-6" 20'-3" DOUBLE 1-1/2"X5-1/2" @ 16" D.C.(" LSL 1.3E 18'4" 18'-6" 18'-3" 21'-6" 21'-3" 21'-C" 24'-0" 23'-9" 23'-6" DOUBLE 1-1/2"X5-1/2" @ 12" 0.06) LSL 1.3E 20'-9" 20'-6" 20'-3" 24'-0" 23'-6" 23'-3" 24'-0" 24'-0" 24'-O" 1-3/4"X5-1/2"@ 16" O.C. LSL 1.55E 16'-6" 16-3" 16-0" 19'-C" 18'-9" 18'-6" 21'-0" 20'-9" 20'-6" 1-3/4"X5-1/2"@ 12" O.C. LSL 1.55E 18'-3" 18%0" 17-9" 21'-0" 20'-9" 20'-6" 23'-3" 23'-0" 22'-9" DOUBLE 1-3/4"X5-1/2" @ 16" D.C.(') LSL 1.55E 21'-0" 20'-9" 20'-6" 24'-0" 24'-0" 24'-0" 24'4- 24'-0" 24'-0" DOUBLE 1-3/4"X5-1/2" @ 12" 0.03j LSL 1.55E 23' 3" 23' 0" 22' 9" 24' 0" 24' 0" 24' 0" 24' 0" 24' 0" 24' 0" 1) LISTED HEIGHTS ARE DISTANCES BETWEEN POINTS OF LATERAL SUPPORT PLACED PERPENDICULAR TO THE PLANE OF THE WALL. 2) DOES NOT INCLUDE CASES WHERE BRICK WEIGHT IS SUPPORTED BY STUDS VIA LINTEL ATTACHED TO STUDS OR BRICK RESTING ON WOOD FRAMING ABOVE. 3) DOUBLE 1 3/4- LSL STUDS SHALL BE CONNECTED WITH SDW22 SCREWS (3-3/8"XO.22") @ 6" O.C. STAGGERED 4) REFERENCE IRC TABLES R602.3(5) AND R602.3(6). 5) DEFLECTION CRITERIA ARE AS FOLLOWS: H1360 FOR STUCCO, H/240 FOR BRICK VENEER, H/180 FOR FLEXIBLE FINISHES WITH DRYWALL INTERIOR FINISH. WHERE INTERIOR FACE OF THE WALL IS COVERED WITH PLASTER, DEFLECTION LIMITS H/360 SHALL BE USED EVEN WITH BRICK OR FLEXIBLE EXTERIOR COVERINGS. 6) BUNDLED STUDS SHALL BE CONNECTED TO EACH OTHER PER TYPICAL NAILING SCHEDULE (NOTE 302.8) 7) PROVIDE ADD'L NAILS AT TOP AND BOT PLATE TO STUD CONNECTION AS FOLLOWS: STUDS > 10'-0" ONE ADD'L NAIL EA CONNECTION STUDS > 14'-0" TWO ADD'L NAILS EA CONNECTION STUDS > 18'-0" - THREE ADD'L NAILS EA CONNECTION STUDS > 22'-0" AND UP TO 24'-0" - FOUR ADD'L NAILS 309.10.2. INTERIOR WALL STUD SCHEDULE: INTERIOR WALL STUD SCHEDULE - SYP MAX LATERALLY UNSUPPORTED STUD HEIGHTI') SUPPORTING STUD SIZE AND SPACING GRADE ONE FLOOR + TWO FLOORS + ROOF +CEILING ROOF + CEILING ROOF + CEILING STUD 1D'-o" 2X4 @ 24' O.C. (2) #z 10'-0" - 2X4 @ 16" O.C. - STUD 10'-0" lo'-o" #2 12'-9" 10'-0" 2X4 @ 12" O.C. STUD 1D'-0" 10'-0" #2 14'-9" 11'-0" STUD 10'-0" 10'-0" 2X6 @ 24" O.C!21 #2 19'-6" 13'-6" 12'-15" STUD 10'-0" 10'-0" 10'-0" 2X6 @ 16" O.C. #2 23'-3" 16-6" 15'-6" 2X6 @ 12" O.C. STUD 10'-0" 10'-0" 10'-0" #2 23'-3" 21'-3" 18'-o" 1) LISTED HEIGHTS ARE DISTANCES BETWEEN POINTS OF LATERAL SUPPORT PLACED PERPENDICULAR TO THE PLANE OF THE WALL. 2) AT SHEARWALLS, MAX STUD SPACING SHALL BE LIMITED TO 16" O.C. 309.11. WHERE "BALLOON FRAMED WALL" IS INDICATED ON PLAN, STUDS SHALL BE CONTINUOUS AS INDICATED WITHOUT TOP PLATES AT INTERMEDIATE FLOORS OR LOW CEILING/ROOF LEVELS. A SINGLE SET OF TOP PLATES SHALL BE PROVIDED ONLY AT THE TOP OF THE BALLOON -FRAMED WALL. 309.12. TYPICAL WALL OPENING SHALL BE FRAMED AS FOLLOWS: C�PL R ARCH c - TOP PLATES ��. CRIPPLE STUDS MATCHING NUMBER WITH JACK \, STUDS BELOW --` CRIPPLE STUD ABOVE HEADER. SPACING TO MATCH TYPICAL WALL FRAMING ADJACENT FULL HEIGHT KING STUD TO END OF HEADER ATTACHMENT PER THE TYPICAL NAILING SCHEDULE (NOTE 302.8) HEADER. BUILT UP PER TYPICAL NAILING SCHEDULE (NOTE 302.8) FOR 2X LUMBER OR NOTE 303.12.2 FOR LVL BEAMS KING STUDS CONTINUOUS FROM SILL PLATE TO TOP PLATE JACK STUDS CONTINUOUS FROM SILL PLATE TO UNDERSIDE OF HEADER \� ROUGH OPENING. REF ARCH WINDOW SILL PLATE PER WINDOW SILL PLATE SCHEDULE CRIPPLE STUD BELOW OPENING B"AL -- SILL (BOTTOM) PLATE PEA ARCH 309.13. HEADERS SHALL HAVE NOT LESS THAN ONE JACK STUD AND ONE KING STUD EACH END OR BE CONNECTED WITH AN APPROVED FRAMING ANCHOR. 309.14. HEADERS ARE NOT REQUIRED AT OPENINGS UP TO 6-0" WIDE IN INTERIOR NON -BEARING WALLS WHERE THE WALL HEIGHT ABOVE THE OPENING IS LESS THAN 2'4'. SUCH LOCATIONS SHALL BE NOTED "N.H.R." ON PLAN. A FLAT 2x MEMBER EQUAL TO WALL WIDTH MAY BE USED: TI PL I i PEJ a TOP PLATES -CRIPPLE STUDS NOT REQUIRED F-4 KING STUD CONTINUOUS FROMSILL PLATE TO TOP T/ROUGH OPENING I - PLATE. ATTACHMENT PER THE TYPICAL NAILING ER J, `� ARCH �i SCHEDULE (NOTE 302.8) FLAT 2X HEADER MATCHING WIDTH OF THE WALL FRAMING -JACK STUD ROUGH OPENING. REF ARCH 309.15. THE MINIMUM NUMBER OF KING STUDS ADJACENT TO AN OPENING SHALL BE DETERMINED BASED ON WALL HEIGHT AND OPENING WIDTH PER THE KING STUD SCHEDULE BELOW: KING STUDS AT EXTERIOR WALL SCHEDULE - WIND: 110 MPH, EXP "B" {3I NUMBER OF KING STUDS(') WALL HEIGHT STUD LUMBER SIZE GRADE 1 I 2 I 3 I 4 I 5 MAX ROUGH OPENING WIDTH 2X4 SYP STUD 8'-0" 18'-0" 24'-0" 2X6 SYP STUD 8'-0" 18'4" 24'-0' 2X4 SYP #2 T-0" 6-0" 10'-0" 14'-C" 18'-0" 2X6 SYP #2 V-0" 20'-0' 24'-0' 2X4 SYP #2 2'-6" 5'-0' 8'-0' 11'4' 14'-0- 12-4" 2X6 SYP #2 8'-0" 16-0" 24'-0' 2X6 SYP #2 5-0" 12'-0" 18'-0' 24'-0' 14'-0" 2X8 SYP #2 V-0" 20'-0' 24'-0' 2X6 SYP #2 3'-0" 8'-0" 13'-0" 18'-C" 23'-0' lfi'-0" 2X8 SYP #2 6D" 14'-0" 22'-0' 24'-0' 2X6 SYP #2 T-O" 8'-0" 12'-C" 16-0" 18'-0" 2X8 SYP #2 5'-0" 11'-0" 18'-0" 24'-0" 2X6 SYP #2 W-O" 6-0" 8'-0" 10'-0' 20'-D" 2X8 SYP #2 W-0" V-0" 14'-0" 19'-0" 24'-0' 2X6 SYP #2 4' 22-0" V-0" 8'-0" '-V 2X8 SYP #2 T-0" 6-0" 10'-0" 14'-0" 18'-0' 24'-0" 2X8 SYP #2 T-O" 8'-0" 11'-0" 14'-0" 1) NUI4BER OF KING STUDS SHOWN IS FOR EACH SIDE OF THE OPENING. KING STUDS ATTACHED TOGETHER PER TYPICAL NAILING SCHEDULE 2 BASED ON 1RC R602.7.5 3) EACH KING STUD SHALL CONNECT 70 TOP AND BOTTOM PLATE PER TYPICAL NAILING SCHEDULE NOTE 302.8. ADDITIONAL NAILS SHALL BE PROVIDED AT EACH KING STUD PER NOTES OF EXTERIOR WALL STUD SCHEDULE (NOTE 309.10.1) ACCORDING TO THE STUD HEIGHT. 309.16. IN VAULTED CEILING AREAS, EXTERIOR WALL STUDS SHALL BE CONTINUOUS FROM SILL PLATE TO THE FULL VAULTED CEILING HEIGHT PER NOTE 309.1. STUD SIZE AND SPACING SHALL BE SELECTED BASED ON THE ACTUAL STUD HEIGHT AT EACH LOCATION. KING STUDS ADJACENT TO OPENINGS WITHIN VAULTED WALLS SHALL EXTEND CONTINUOUSLY FROM THE SILL PLATE TO THE TOP OF THE VAULTED CEILING AND SHALL BE LATERALLY BRACED BY THE ROOF OR CEILING FRAMING AT THE TOP AS FOLLOWS: / TOP PLATES, TYPICAL NO TOP PLATES ALLOWED MID STUD HEIGHT KING STUDS AT SIDE OF OPENING CONTINUOUS TO TOP PLATES. SELECTED PER KING STUD \ SCHEDULE BASED ON ACTUAL STUD HEIGHT AT EACH LOCATION \HEADER JACK STUDS REGULAR STUDS CONTINUOUS FROM SILL TO TOP PLATE 309.17. WINDOW OPENINGS SHALL HAVE SILL PLATES SIZED AND SELECTED PER THE SILL PLATE SCHEDULE BELOW. ADDITIONAL SILL PLATES MAY BE REQUIRED AT WIDER OPENINGS. REFER TO THE ARCHITECTURAL DRAWINGS FOR OPENING DIMENSIONS. WINDOW SILL PLATE SCHEDULE. MAX OPENING WIDTH BASED ON QUANTITY AND SIZE OF WINDOW SILL PLATES(lX4) -WIND: 110MPH, EXP "B" QUANTITY OF WINDOW SILL PLATES WALL THICKNESS 1 �2X3X5) 3(2X3X5) 4(2X3X5) 2X4 6'-3" 8' 1" 9'-3- 2X6 10'-1" 12'-8" 14'-6" 16'-0" 2X8 13' 3" 16' 9" 19' 3" 2V-3" 1) THIS SCHEDULE I5 BASED ON A MAXIMUM TRIBUTARY HEIGHT TO THE WINDOW SILL OF 10'-0". THIS TRIBUTARY HEIGHT MAY REPRESENT EITHER THE DISTANCE FROM THE FLOOR TO THE WINDOW HEADER OR THE VERTICAL DISTANCE BETWEEN TWO HEADERS IN CASES WHERE OPENINGS ARE VERTICALLY ALIGNED WITHIN THE SAME WALL. SILL PLATES SHALL BE CONTINUOUS BETWEEN KING STUDS ON SIDES OF OPENING. 2) CONNECT EACH ADDITIONAL SILL PLATE TO THE PLATE BELOW USING 10D NAILS (3" X 0.148") SPACED AT 12" ON CENTER, STAGGERED, 3) EACH SILL PLATE SHALL BE CONNECTED TO THE ADJACENT FULL HEIGHT KING STUD AS REQUIRED PER TYPICAL NAILING SCHEDULE. 4) THE SILL PLATE SCHEDULE MAY BE USED AS A REFERENCE FOR DETERMINING THE SIZE OF THE BOTTOM PLATE OF A SOFFIT IN AN EXTERIOR WALL WHERE NO HEADER IS REQUIRED OR WHERE THE HEADER IS INSTALLED DIRECTLY BENEATH THE TOP PLATES AND FRAMED DOWN TO ACHIEVE THE REQUIRED OPENING HEIGHT. 5) CONNECT FIRST WINDOW PLATE TO THE CRIPPLE STUDS PER TYPICAL NAILING SCHEDULE "TOP OR SOLE PLATE TO STUD CONNECTION" REQUIREMENT 309.18. WHERE A LOW ROOF INTERSECTS AN EXTERIOR WALL AT MID -HEIGHT, EXTERIOR WALL SHEATHING SHALL BE INSTALLED CONTINUOUSLY FROM THE SILL PLATE TO THE TOP PLATE, THROUGH THE LOW ROOF FRAMING: ROOF/CEILING FRAMING EXTERIOR WALL FRAMING LOW ROOF FRAMING. NAILER/BLOCKING AS REQ'D EXTERIOR WALL SHEATHING CONTINUOUS FROM SILL PLATE TO TOP PLATE, THROUGH LOW ROOF FRAMING SILL PLATE AT BOT OF WALL _ FOUNDATION OR FRAMING BELOW Vv S * 1 ........................... .ALIAKSEI PATSEVICH .%.............. 130521•r • �O,c �'•�I �ENSE�•'" N•• ASS/• NGX� 1 O E N ice_ AL w OZ Z W Z 0 LIJ Lill Z W z Z O0w J M cn � O m U Z lnlC W z W LL_ Wiz W O ~ 0 J 114- _ --q U X mLu Ln 7 Q L. in�- cr ,--1 00 N REVISIONS 0 DATE Ln N �O 0 . PROJECT NAME 101 CROSS CREEK GARAGE ADDITION PROJECT ADDRESS 101 CROSS CREEK DR GRAPEVINE, TX PROJECT NUMBER S26129 CHECKED BY - AP SHEET DATE - 05/04/2026 Z _O U Ln W SCALE 24X36 SHEET:1/2"=V-0" J 1_ - W 0 z Q W 0 z 9 LL_ FRAMING PLAN NOTES FOR TYPICAL MATERIAL, INSTALLATION, AND STANDARD DETAIL REQUIREMENTS, REFER TO THE GENERAL FRAMING NOTES (GN301) AS FOLLOWS: ........................... ALIAKSEI PATSEVICH 2 JACK 3 CRIPPLE 1 KING STUDS BELOW i 2-PLY 2 JACK \ I I I I I 11KING I I I J ;; I I N " 3 JACK I I I I I I I I I I 3 KING Lu J O > .. co i I Q I � J x .l Q rr' Lu M I p EL Ui N O w I m O 161" TJI360 @ 16" O.C. .• I I �1 3 JACK 3 KING I I II I I 3 STUDS BELOW 3 STUDS �► BELOW IN 2-PLY 2X6 LUS26-2 J >r. X M 2-PLY 1 3/4' `\ X 1611 LV X I r 3 STUDS BELOW TYPICAL FASTENERS AND NAILING SCHEDULE — SEC. 302 LUMBER AND SHEATHING MATERIALS — SEC. 303 FRAMING PENETRATIONS — SEC. 304 TYPICAL ROOF FRAMING — SEC. 305 TYPICAL CEILING FRAMING — SEC. 306 TYPICAL FLOOR FRAMING — SEC. 307 TYPICAL WALL FRAMING — SEC. 309 TYPICAL DECK FRAMING — SEC. 308 TYPICAL MULTIPLY LVL BEAM CONNECTION - NOTES 303.12 AND 303.13 TYPICAL HANGER SCHEDULE - NOTE 303.14 STUD WALL SCHEDULES: EXTERIOR WALLS -NOTE 309.10.1 INTERIOR WALLS - NOTE 309.10.2 KING STUD SCHEDULE - NOTE 309.15 ADDITIONAL REQUIREMENT AT SHEAR WALL LOCATIONS, REFER TO SHEAR WALL PLANS AND SHEAR WALL GENERAL NOTES (GN401) SEE ALSO: GENERAL STRUCTURAL NOTES (GN100) FOR ADDITIONAL MATERIAL, INSPECTION, AND CONTRACTOR RESPONSIBILITY REQUIREMENTS. WHERE SPECIFIC NOTES OR DETAILS ARE SHOWN ON THE PLANS, THOSE SHALL GOVERN. q 130521 ;` I �P�,� �'•���ENSE�••'•� �� W pOZ z 0 W oa z w Zwz Z Z 00W J M Ql boo �p U u w � w w � z z > '-' _j 0 ,u o_ z w X O r� @ x> m cn Q L oL Q 00 CV N REVISIONS DATE BY PROJECT NAME 101 CROSS CREEK GARAGE ADDITION PROJECT ADDRESS 101 CROSS CREEK DR GRAPEVINE, TX PROJECT NUMBER S26129 CHECKED BY - AP SHEET DATE - 05/04/2026 SCALE 24X36 SHEET:1/2"=1'-0" z z Q oc ROOF U z 2ND FLOOR L J 1ST FLOOR/ FOUNDATION z w J ry) -I- a w U) LEVEL KEY rw� J U w � Lu � w LL ul) FRAMING PLAN NOTES -1 JACK 2 KING D E: 2-PLY 2X12 i J 0 x M N _ d N � ..• LSSR410-2 ,D-rLI 1 J/`t A 2 JACK %7- LUS210-3 WHO N X N ... "10-PLY 2X12 1 JACK 2 KING LRU26,TYP 0 .0 LVL x 2 JACK N FOR TYPICAL MATERIAL, INSTALLATION, AND STANDARD DETAIL REQUIREMENTS, REFER TO THE GENERAL FRAMING NOTES (GN301) AS FOLLOWS: TYPICAL FASTENERS AND NAILING SCHEDULE — SEC. 302 LUMBER AND SHEATHING MATERIALS — SEC. 303 FRAMING PENETRATIONS — SEC. 304 TYPICAL ROOF FRAMING — SEC. 305 TYPICAL CEILING FRAMING — SEC. 306 TYPICAL FLOOR FRAMING — SEC, 307 TYPICAL WALL FRAMING — SEC. 309 TYPICAL DECK FRAMING — SEC. 308 TYPICAL MULTIPLY LVL BEAM CONNECTION - NOTES 303.12 AND 303.13 TYPICAL HANGER SCHEDULE - NOTE 303.14 STUD WALL SCHEDULES: EXTERIOR WALLS -NOTE 309.10.1 INTERIOR WALLS - NOTE 309.10.2 KING STUD SCHEDULE - NOTE 309.15 ADDITIONAL REQUIREMENT AT SHEAR WALL LOCATIONS, REFER TO SHEAR WALL PLANS AND SHEAR WALL GENERAL NOTES (GN401) SEE ALSO: GENERAL STRUCTURAL NOTES (GN100) FOR ADDITIONAL MATERIAL, INSPECTION, AND CONTRACTOR RESPONSIBILITY REQUIREMENTS. WHERE SPECIFIC NOTES OR DETAILS ARE SHOWN ON THE PLANS, THOSE SHALL GOVERN. ROOF 2ND FLOOR 1ST FLOOR/ FOUNDATION LEVEL KEY ALIAKSEI PATSEVICH .A. .•.130521 OFS ..• ��• `1\iL'ONAL ENS~ W Q 0 Z z 0 W oa z w Zwz Z Z 00W J M Ql boo �p U .-� u w � w w � z z > '-' _j 0 Lu o_ z w X O x> m cn .~ Q L CL Q ai 00 N N REVISIONS DATE BY PROJECT NAME 101 CROSS CREEK GARAGE ADDITION PROJECT ADDRESS 101 CROSS CREEK DR GRAPEVINE, TX PROJECT NUMBER S26129 CHECKED BY - AP SHEET DATE - 05/04/2026 SCALE 24X36 SHEET:1/2"=1'-0" z Q C� Z N z0 M a pa[ L.L (I? rw� U w U- 0 0 w DC = GN401. GENERAL SHEAR WALL NOTES,_ TYPICAL DETAILS AND SCHEDULES 401. GENERAL 401.1. REFER TO GENERAL STRUCTURAL NOTES (SECTIONS 100 THROUGH 127) FOR ALL ADDITIONAL REQUIREMENTS APPLICABLE TO MATERIALS, FASTENERS, CONNECTORS, INSPECTIONS, DELEGATED DESIGN, SUBMITTALS, AND ALL OTHER WORK NOT SPECIFICALLY ADDRESSED IN THESE SHEAR WALL NOTES. IN CASES OF CONFLICT, THE MORE STRINGENT REQUIREMENT SHALL GOVERN PER NOTE 100.4. 401.2. THESE NOTES APPLY TO LATERAL BRACING SYSTEMS INCLUDING WOOD STRUCTURAL PANELS (WSP) SHEAR WALLS, PORTAL FRAMES, CONTINUOUSLY SHEATHED BRACED WALL PANELS, AND PROPRIETARY PREFABRICATED SHEAR WALL UNITS IN WOOD -FRAMED RESIDENTIAL CONSTRUCTION. 401.3. CONSTRUCTION SHALL CONFORM TO THE LATEST ADOPTED EDITIONS OF INTERNATIONAL BUILDING CODE, WFCM (AWC), AND NOS. WHERE THESE NOTES OR THE STRUCTURAL DRAWINGS IMPOSE A MORE STRINGENT REQUIREMENT, THAT REQUIREMENT SHALL GOVERN. 401.4. SHEAR WALLS ARE DESIGNATED ON PLAN (E.G., SW6, SW4, ETC.) AND SHALL BE CONSTRUCTED PER THE CORRESPONDING ROW OF THE SHEAR WALL SCHEDULE, WHICH GOVERNS SHEATHING, NAILING, FRAMING, BOUNDARY MEMBERS, AND ANCHORS FOR EACH WALL. 401.5. THE CONTRACTOR SHALL VERIFY ALL SHEAR WALL LOCATIONS, LENGTHS, HEIGHTS, AND HOLDOWN LOCATIONS AGAINST THE STRUCTURAL AND ARCHITECTURAL DRAWINGS PRIOR TO FRAMING. DISCREPANCIES SHALL BE REPORTED TO THE FOR IMMEDIATELY. 402. MATERIALS 402.1. SHEATHING 402.1.1. WSP SHEATHING SHALL COMPLY WITH APA PRP-108 (PLYWOOD) OR PRP-210 (OSB), PS 1 OR PS 2, AND SHALL BEAR A VALID APA GRADE STAMP. PANELS SHALL BE RATED EXPOSURE 1 OR EXTERIOR. (SEE NOTES 108.1-108.3). 402.1.2. MINIMUM PANEL THICKNESS, GRADE, AND SPAN RATING SHALL BE PER THE SHEAR WALL SCHEDULE AND NOTE 303.4. 402.1.3. WHERE GYPSUM WALLBOARD IS LISTED IN THE SHEAR WALL SCHEDULE, IT SHALL BE MINIMUM 1/2" CONFORMING TO ASTM C1396 AND FASTENED PER THE SCHEDULE. GWB SHALL NOT BE THE SOLE LATERAL -RESISTING ELEMENT UNLESS SPECIFICALLY DESIGNATED BY THE EOR. 402.2. FRAMING 402.2.1. ALL FRAMING LUMBER FOR BOUNDARY MEMBERS, CHORD STUDS, POSTS, AND SILL PLATES SHALL MEET THE SPECIES AND GRADE OF NOTE 303.2. WHERE THE SHEAR WALL SCHEDULE INDICATES MULTIPLE STUDS (E.G., (2) OR (3) STUDS), ALL SHALL BE INSTALLED AND CONNECTED PER NOTE 302.7. 402.2.2. WHERE A 3X SILL PLATE IS REQUIRED BY THE SCHEDULE, IT SHALL BE CONTINUOUS FOR THE FULL SHEAR WALL LENGTH. A 3X MEMBER SHALL NOT BE SUBSTITUTED WITH MULTIPLE 2X MEMBERS WITHOUT FOR APPROVAL. 402.3. FASTENERS AND CONNECTORS 402.3.1. FASTENER CORROSION PROTECTION SHALL BE PER NOTES 110.1-110.12 AND 111.1-111.9. NAIL TYPE, SIZE, AND QUANTITY SHALL BE PER THE SHEAR WALL SCHEDULE. SUBSTITUTIONS ARE NOT PERMITTED WITHOUT WRITTEN FOR APPROVAL, 402.3.2. HOLDOWNS, STRAPS, AND TENSION TIES SHALL BE SIMPSON STRONG -TIE OR APPROVED EQUAL, INSTALLED WITH THE FULL COMPLEMENT OF MANUFACTURER -SPECIFIED FASTENERS TO ACHIEVE RATED CAPACITY. ANCHOR BOLTS AND RODS SHALL BE INSTALLED PRIOR TO CONCRETE PLACEMENT PER NOTE 203.1. 403. SHEAR WALL CONSTRUCTION 403,1. SHEATHING INSTALLATION 403.1.1. WSP SHEATHING SHALL BE INSTALLED WITH THE LONG DIMENSION VERTICAL (PARALLEL TO STUDS) UNLESS THE SCHEDULE INDICATES HORIZONTAL. SHEATHING SHALL BE CONTINUOUS FROM SILL PLATE TO TOP PLATE WHERE POSSIBLE. (SEE NOTE 309.8.) 403.1.2. VERTICAL PANEL JOINTS SHALL OCCUR OVER STUDS; HORIZONTAL JOINTS SHALL OCCUR OVER FULL -DEPTH BLOCKING. PROVIDE 1/8" EXPANSION GAPS AT ALL PANEL EDGES AND ENDS. (SEE NOTES 309.9 AND 108.5.) 403.1.3• WHERE SHEATHING IS REQUIRED ON BOTH FACES, PANEL JOINTS SHALL BE OFFSET A MINIMUM OF ONE STUD SPACE BETWEEN FACES AND STAGGERED VERTICALLY. 403.2. NAILING 403.2.1. EDGE AND FIELD NAILING SHALL BE PER THE SHEAR WALL SCHEDULE. NAILS SHALL BE DRIVEN FLUSH; OVERDRIVEN NAILS SHALL BE SUPPLEMENTED PER NOTE 302.5. 403.2.2• WHERE SCHEDULE EDGE SPACING IS 2" OR 3", 3X SILL PLATES, DOUBLE BOUNDARY STUDS, AND 3X BLOCKING SHALL BE PROVIDED PER THE SCHEDULE TO PREVENT SPLITTING, 403.3. BOUNDARY MEMBERS 403.3.1. END STUDS SHALL BE MINIMUM (2) FULL -HEIGHT STUDS AT EACH END OF ALL SHEAR WALLS, INSTALLED CONTINUOUSLY FROM SILL PLATE TO TOP PLATE WITHOUT SPLICES AND CONNECTED PER NOTE 302.7. WHERE HOLDOWNS ARE REQUIRED, ADDITIONAL STUDS MAY BE REQUIRED AT HOLDOWN LOCATIONS - REFER TO HOLDOWN SCHEDULE FOR MINIMUM STUD QUANTITIES AT EACH HOLDOWN TYPE. WHERE THE QUANTITY OF STUDS IS SHOWN ON PLAN, THAT QUANTITY SHALL GOVERN OVER THE SCHEDULE. 403.3.2. BOUNDARY MEMBERS SHALL BEAR CONTINUOUSLY ON MEMBERS BELOW THAT TRANSFER OVERTURNING FORCES TO THE FOUNDATION. ALL BOUNDARY MEMBER LOAD PATHS SHALL BE CONTINUOUS. 403.4. BLOCKING 403.4.1. HORIZONTAL BLOCKING SHALL BE PROVIDED BETWEEN STUDS AT ALL HORIZONTAL SHEATHING PANEL JOINTS. BLOCKING SHALL BE MINIMUM 2x FULL -DEPTH, MATCHING STUD DEPTH, UNO PER SCHEDULE. 403.4.2. AT FLOOR LEVELS BETWEEN STORIES, FULL -DEPTH BLOCKING, RIM BOARD, OR CONTINUOUS FRAMING SHALL TRANSFER SHEAR THROUGH THE FLOOR WITHOUT INTERRUPTION. SEE STRUCTURAL DETAILS AND NOTES 307.6 AND 403.6. 403.5. SILL PLATE ANCHORING 403.5.1. SILL PLATES AT SHEAR WALL LOCATIONS SHALL BE ANCHORED PER THE SHEAR WALL SCHEDULE. ANCHOR BOLTS SHALL BE INSTALLED WITHIN 12" OF EACH END OF EACH SILL PLATE SEGMENT, UNLESS CLOSER SPACING IS REQUIRED. (SEE NOTES 309.5 AND 309.6.) 403.5.2. STANDARD CUT WASHERS SHALL BE PROVIDED AT SILL PLATE ANCHOR BOLTS AT SHEAR WALL LOCATIONS, UNO. WHERE THE SHEAR WALL SCHEDULE INDICATES SQUARE PLATE WASHERS, THEY SHALL BE MINIMUM 3"x3"x0.229" THICK. CUT WASHERS SHALL NOT BE SUBSTITUTED FOR PLATE WASHERS WHERE PLATE WASHERS ARE SPECIFICALLY REQUIRED BY THE SCHEDULE. 0'-4" MIN V ' MAX ANCHOR BOLT SPACI G PER SHEAR WALL SCHEDUL OR PER NOTE 309.6 0 0 MINIMUM 2 ANCHORS OLTS PER SEGMENT SILL PLATE ANCHORING PLAN VIEW 403.6. SHEAR TRANSFER AT FLOOR AND ROOF LEVELS 403.6.1• SHEAR SHALL BE TRANSFERRED CONTINUOUSLY FROM THE ROOF DIAPHRAGM THROUGH EACH STORY TO THE FOUNDATION. THE LOAD PATH SHALL NOT BE INTERRUPTED WITHOUT WRITTEN FOR AUTHORIZATION. 403.6.1.1. WHERE A SHEAR WALL IS DESIGNATED AT A WALL WITH A GABLE END OR ATTIC WALL ABOVE THE TOP PLATE, THE SHEAR WALL SHEATHING AND NAILING REQUIREMENTS SHALL EXTEND CONTINUOUSLY FROM THE SILL PLATE OF THE DESIGNATED SHEAR WALL THROUGH THE TOP PLATE AND FULL HEIGHT OF THE GABLE OR ATTIC WALL TO THE TOP PLATES OF THE ROOF FRAMING ABOVE. THE SHEATHING AND NAILING SHALL BE PER THE SAME SHEAR WALL DESIGNATION UNLESS OTHERWISE NOTED ON PLAN. 403.6.2. SHEAR TRANSFER HARDWARE (BLOCKING, STRAPS, SHEAR PLATES) AT EACH FLOOR LEVEL SHALL BE INSTALLED AND NAILED PER THE STRUCTURAL DETAILS AND SHEAR WALL SCHEDULE BEFORE COVERING. 404. HOLDOWNS AND OVERTURNING RESTRAINT 404.1. HOLDOWNS SHALL BE PROVIDED AT LOCATIONS SHOWN ON PLAN AND SHALL BE INSTALLED WITH ALL MANUFACTURER -SPECIFIED FASTENERS IN ALL PREPUNCHED HOLES. 404.2. HOLDOWN ANCHOR RODS SHALL EXTEND FROM THE HOLDDOWN HARDWARE AND EMBEDDED INTO THE FOUNDATION. 404.3. CONTINUOUS ROD SYSTEMS SHALL INCORPORATE SHRINKAGE -COMPENSATING TAKE-UP DEVICES AT EACH FLOOR LEVEL AND SHALL BE TIGHTENED AFTER FRAMING AND BEFORE FINISHES, AND RE -TIGHTENED AS DIRECTED BY THE MANUFACTURER. 404.4. HOLDOWN ANCHORS SHALL BE INSTALLED PLUMB IN THE CORRECT LOCATION PRIOR TO CONCRETE PLACEMENT. SEE NOTE 203.1 FOR EMBEDDED HARDWARE REQUIREMENTS. 404.5. WHERE HOLDOWNS ARE INDICATED PER PLAN, ADDITIONAL REQUIREMENTS ARE AS APPLICABLE PER HOLDOWN SCHEDULE BELOW: HOLDOWN SCHEDULE HOLDOWN ANCHOR MIN ANCHOR EMBEDMENT MIN WOOD POST SIZE CALLOUT DIAMETER STHD14 (2)-2X STUDS 5THD14RJ - - (2)-2X STUDS HDUE3-SDS3 5/8" 1'-0. (2)-2X STUDS HDUE5-SDS3 5/8'. V-6" (2)-2X STUDS HDUE7-SDS3 5/8" V-6" (2)-2X STUDS HDUE9-SOS3.5 7/8" 1'-10" (3)-2X STUDS HDU13-SDS3.5 1" T-0" 4X8 POST HDUE17-SDS3.5 1" 2'-0" 6X6 POST DTT1Z 3/8" 1'-0" (1)-2X STUD DTT2Z 1/2" 1'-0" (2)-2X STUDS 404.6. WHERE HOLDOWN IS SHOWN PER PLAN IN A CORNER OF A WALL, THE CORNER FRAMING SHALL BE AS FOLLOWS: 404.6.1. PLAN VIEW AT EXTERIOR CORNER: HOLDOWN PER PLAN (SIM WITH STHD14 ON SIDE) BUNDLED STUDS OR POST PER PLAN OR PER HOLDOWN SCHEDULE WALL SHEATHING PANEL EDGE NAILING PER APPLICABLE SHEAR WALL CALLOUT t x 404.6.2. PLAN VIEW AT INTERIOR CORNER: -J� 0.148"X3 1-1/4" NAILS @ PANEL �.0 EDGE NAILING SPACING WALL SHEATHING PANEL EDGE NAILING PER APPLICABLE SHEAR WALL CALLOUT BUNDLED STUDS OR POST PER PLAN OR PER HOLDOWN SCHEDULE HOLDOWN PER PLAN (SIM WITH STHD14 ON SIDE) 405. PORTAL FRAMES 405.1. PORTAL FRAME ASSEMBLIES SHALL BE USED WHERE SPECIFICALLY CALLED OUT ON PLAN AND SHALL COMPLY WITH THE LATEST EDITION OF THE INTERNATIONAL BUILDING CODE. PORTAL FRAMES SHALL BE CONSTRUCTED WITH STUDS #2 GRADE OR BETTER. CONSTRUCTION DETAILS SHALL BE AS FOLLOWS: 405.1.1• SINGLE SIDE PORTAL FRAME SW-PFl: EXTENT OF HEADER WITH SINGLE PORTAL FRAME ROUGH OPENING WIDTH (2'-0" MIN, 18'-0" MAX) = rl � zw IH• II 11: 'II p= IJ II a li I I I] HEADER PER PLAN (MIN 2-PLY 2X12) ----FASTEN SHEATHING TO HEADER WITH 0.131"X2-1/2" NAIL IN 3" GRID PATTERN AS SHOWN -' is ''= HEADER TO JACK STUD STRAPPER PORTAL FRAME u STRAP AT HEADER SCHEDULE. ADD'L STUD - u a REQUIRED WHERE MULTIPLE STRAPS REQUIRED. o STRAP LENGTH AS REQUIRED FROM TOP PLATES TO x = EXTEND 1'-4" PAST HEADER ..... . ... MIN DOUBLE STUDS AT ENDS. ADD'L STUDS MAY o BE INDICATED PER PLAN. FASTEN SHEATHING WITH -- - 0.131"72-1/2" NAILS @ 3"O.C. TO EACH STUD - SHEATHING SPLICES ACCEPTABLE WITHIN THE MIDDLE 2'-0" OF THE WALL. PROVIDE BLOCKING AND NAILING @ 3"O.C. STH D 14 H OLDOWN +r: DOUBLE SILL PLATE AT PORTAL FRAME MIN (2) 1/2" DIA ANCHOR BOLTS - WITH 7" EMBEDMENT INTO CONCRETE ITI I I I I I I I I I I I I LJ LJ LJ 405.1.2. DOUBLE PORTAL FRAME SW-PF2: EXTENT OF HEADER WITH DOUBLE PORTAL FRAME ROUGH OPENING WIDTH (2'4" MIN, 18'-0" MAX) 1•I HI hl hl • is : � �� : 11' hl 14 - }p 11 ; E.1 17 ; ; I:1 IIa 1.1 .. H• •rl .. . REF SINGLE PORTAL FRAME FOR----_ , u NAILING/STRAPPING REQUIREMENTS I I I I I I I I I I I I I I I I I I I I I I I I LJ LJ LJ LJ 405.1.3. PORTAL FRAME SECTION: � T/ PL PEY R ARCH TENSION STRAP ON OPPOSITE SIDE OF SHEATHING t--FASTEN KING STUD TO HEADER W/ (6) 0.148"73-1/4" NAILS T/RO PE RRCCH-TOP PLATE TO HEADER W/ TWO ROWS OF 0.148"X3-1/4" NAILS SHEATHING SPLICES ACCEPTABLE WITHIN THE MIDDLE 2'-0" OF THE WALL. PROVIDE BLOCKING AND NAILING @ 3"O.C. ,.---STHD14 HOLDOWN ---,,-ANCHOR BOLTS DOUBLE SILL PLATES i J 405.1.4. PORTAL FRAME STRAP AT HEADER SCHEDULE: PORTAL FRAME STRAP AT HEADER SCHEDULE WALL WIDTH MAXIMUM OPENING WIDTH (#2 GRADE REQ'D) WALL HEIGHT STRAP DETAILS 9'-0" 16•0" 181•0" 10'-0" MAX STRAP CS16 (2)-CS16 (2)-CS16 2X4 12'-0" MAX STRAP (2) CS16 (2)-CS16 N/A 2X6 12'-0" MAX STRAP CS16 (2)-CS16 (2)-CS16 OR WIDER 406. SPECIAL BRACING ELEMENTS 406.1. PROPRIETARY PREFABRICATED SHEAR WALL PANELS (E.G., SIMPSON STRONG -WALL OR EQUAL) SHALL BE THE EXACT TYPE AND SIZE DESIGNATED ON PLAN. ANCHOR BOLTS AND HARDWARE SHALL BE INSTALLED PER STRUCTURAL DETAILS AND THE MANUFACTURER'S TEMPLATE PRIOR TO CONCRETE PLACEMENT. SUBSTITUTIONS REQUIRE WRITTEN FOR APPROVAL. 407. INSPECTION AND QUALITY CONTROL 407.1. SHEAR WALL FRAMING, SHEATHING, NAILING, HOLDOWNS, AND ANCHOR HARDWARE SHALL BE INSPECTED AND APPROVED PRIOR TO COVERING BY THE BUILDING OFFICIAL OR A QUALIFIED INSPECTOR AND/OR REPRESENTATIVE OF THE FOR WHEN REQUIRED BY THE LOCAL JURISDICTION. COVERING WITHOUT PRIOR INSPECTION AND APPROVAL IS NOT PERMITTED. THE CONTRACTOR SHALL PROVIDE ADEQUATE NOTICE AND ACCESS FOR INSPECTION. 407.2. WHERE SPECIAL INSPECTIONS ARE REQUIRED BY THE APPLICABLE BUILDING CODE OR THE LOCAL JURISDICTION, INSPECTIONS FOR NAILING, BOLTING, ANCHORING, AND HOLDOWN INSTALLATION SHALL BE PER THE STATEMENT OF SPECIAL INSPECTIONS (NOTE 125.1). HOLDOWN RODS AND ANCHOR BOLTS SHALL BE INSPECTED PRIOR TO CONCRETE PLACEMENT FOR CORRECT SIZE, LOCATION, EMBEDMENT, AND PROJECTION, SPECIAL INSPECTIONS ARE NOT REQUIRED FOR STRUCTURES CLASSIFIED AS R-3 OCCUPANCY UNLESS SPECIFICALLY REQUIRED BY THE LOCAL JURISDICTION OR THE AUTHORITY HAVING JURISDICTION (AHJ). 407.3. WHERE DISCREPANCIES ARE IDENTIFIED, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE FOR AND SHALL NOT CONCEAL THE AFFECTED AREA UNTIL WRITTEN DIRECTION IS RECEIVED. A COPY OF THE SHEAR WALL SCHEDULE AND APPLICABLE DETAILS SHALL BE MAINTAINED ON THE JOBSITE THROUGHOUT FRAMING. 408. A NOTE ON FLEXIBLE STRUCTURAL SHEATHING SUBSTITUTION 408.1. WHILE THE MANUFACTURER'S PUBLISHED DESIGN VALUES MAY INDICATE THAT CERTAIN FLEXIBLE STRUCTURAL SHEATHING PRODUCTS ARE SUITABLE FOR RESISTING LATERAL LOADS, THE ENGINEER OF RECORD DOES NOT RECOMMEND THE USE OF ANY FLEXIBLE STRUCTURAL SHEATHING AS A SUBSTITUTE FOR WOOD STRUCTURAL PANEL SHEATHING AT ANY DESIGNATED SHEAR WALL LOCATION. INDEPENDENT TESTING CONDUCTED AT CLEMSON UNIVERSITY, THE UNIVERSITY OF OKLAHOMA, AND THE APA RESEARCH CENTER CONCLUDED THAT FLEXIBLE STRUCTURAL SHEATHING MATERIALS OVERSTATE THEIR LATERAL LOAD RESISTANCE BY AS MUCH AS 42 PERCENT WHEN COMPARED TO THEIR PUBLISHED DESIGN VALUES. THE CONTRACTOR AND OWNER ARE DIRECTED TO APA PRODUCT ADVISORY SP-1186, PERFORMANCE OF FLEXIBLE STRUCTURAL SHEATHING (INDEPENDENT EVALUATIONS OF PUBLISHED DESIGN VALUES), JULY 2018, FOR A FULL DISCUSSION OF THESE FINDINGS. FLEXIBLE STRUCTURAL SHEATHING PRODUCTS SHALL NOT BE SUBSTITUTED FOR WSP SHEATHING AT SHEAR WALL LOCATIONS WITHOUT PRIOR WRITTEN APPROVAL FROM THE EOR. 409. SHEAR WALL SCHEDULE WOOD STRUCTURAL PANEL SHEAR WALL SCHEDULE (WIND ONLY) CONNECTION REQUIREMENT SHEAR Q 0 Q WALL WALL FLOOR/ROOF CALLOUT SHEATHING WALL SHEATHING PANEL ANCHOR BOLT SILL PLATE NAILING TOE NAIL AT FLANGE PANEL EDGE PER PLAN EDGE/FIELD NAIL SPACING SPACING TO RIM/BLKG BELOW RIM/BLKG NAILING NAILING 0.131"X2-1/2" 1/2"0, 7" EMBED 0.131"X3-1/2" 0.131"X3" 0.131"X2-1/2" 0.131"XZ-1/2" SW6 7/16" 6" O.C./12" O.0 (6) 4'-0" O.C. 6" O.0 4' O.C. 6" O.C.("'1 6" O.C. SW4 7/16" 4" O.C./12" O.0 (6) 2'-8" O.C. 4" O.C. (3) 3" O.C. 4" O.C. (3) 4" O.C. SW3 7/16" 3" O.C./12" O.C.161 T-0" O.C. 3" O.C. {4I 2" O.C. 3" O.C. (4X11) (2) ROWS @ 4" O.C.ISI SW2 7/16" 2" O.C.112. O.C.(6) 1' 4" O,C. (2) ROWS @ 2" 0 C (2) ROWS @ (2) ROWS @ 4" O.C.(31(S) 4' O.C.(3„S) 4" D.C.'-) PORTAL FRAME CALLOUTS SW-PFI I SINGLE PORTAL FRAME. REF NOTE 405.1.1 FOR FRAMING REQUIREMENTS SW-PF2 DOUBLE PORTAL FRAME REF NOTE 405.1.2 FOR FRAMING REQUIREMENTS 1) ALLEXTERIOR WALLS NOT DESIGNATED AS SHEARWASLL SHALL BE SHEATHED SIM TO SW6, PROVIDE ANCHOR BOLTS @ 72" O.C. 2) ADJOINING PANEL EDGES STAGGERED ON EACH SIDE OF WALL SHALL BE OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS 3) MIN 1-1/4" RIM/BLOCKING THICKNESS BELOW 4) MIN 1-1/2" RIM/BLOCKING THICKNESS BELOW, CAN BE REPLACED WITH TWO ROWS OF NAILS @ 4" O.C. INTO 1-1/4" RIM/BLOCKING 5) PROVIDE ADDITIONAL JOIST OR BLOCKING FOR EACH ADDITIONAL ROW OF NAILS 6) PANEL FIELD NAILING SHALL BE WE' O.C. WHEN STUDS WITHIN SHEAR WALL ARE SPACED 16" O.C. OR LESS. WHEN STUDS ARE SPACED @ 24"O.C. FIELD SHALL MATCH PANEL EDGE NAILING 7) 'WHERE NAILING IS SPECIFIED AT 2. O.C., ADDITIONAL 2X MEMBER IS REQUIRED AT ALL ADJOINING PANEL EDGES (STUDS, PLATES, BLOCKING). CONNECT ADDITIONAL FRAMING TOGETHER W'/ 0.131" X 3" NAILS AT SAME SPACING AS SPECIFIED PANEL EDGE NAILING 8) NAILS SHALL BE LOCATED AT LEAST 3/8" FROM PANEL EDGES 9) REF 303.4 FOR SHEATHING REQUIREMENTS 10) AT GABLE END, ROOF SHEATHING NAILING SHALL BE LIMITED TO 4" O.C. REF NOTE 305.20 FOR ADDT INFORMATION 11) NAILING INTO TJI JOIST FLANGE IS LIMITED TO 4" O.C. AT SW3, ADDITIONAL JOIST OR ROW OF BLOCKING SHALL BE PROVIDED AND FLOOR/ROOF PANEL EDGE NAILING SHALL BE (2) ROWS @ 4" O.C. 410. STANDARD DETAILS 410.1. ROOF SHEAR TRANSFER DETAILS: 410.1.1. SHEAR CONNECTION REQUIREMENTS AT HIP ROOF FRAMING SHALL BE AS FOLLOWS: ROOF SHEATHING PANEL EDGE NAILING INTO BLOCKING 0 FULL DEPTH SOLID BLOCKING WITH VENT HOLES AS REQUIRED. PROVIDE AT ALL RAFTERS 2X10 OR LARGER, ALL TJI RAFTERS, AND AT ALL SHEAR WALL LOCATIONS T/PL WITH PANEL EDGE NAILING 4" O.C. OR LESS (I.E. SW4, SW3, SW2) PE TOE NAIL NAIL AT RIM/BLKG PER SHEARWALL SCHEDULE WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE 1O SHEAR WALL PER PLAN CALLOUT 410.1.2. SHEAR CONNECTION REQUIREMENTS AT GABLE END ROOF FRAMING SHALL BE AS FOLLOWS: VT/PL PER ARCH ROOF SHEATHING PANEL EDGE NAILING INTO BLOCKING 5O ATTIC FULL DEPTH SOLID BLOCKING. - TOE NAIL NAIL AT RIM/BLKG PER SHEARWALL SCHEDULE WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE O WALL SHEATHING CONTINUOUS OVER GABLE END WALL SIMILAR ��T�__/__P�L TO THE REQUIREMENT OF SHEAR WALL CALLOUT BELOW DER�ARCH WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE O SHEAR WALL PER PLAN CALLOUT 410.2. ELEVATED FLOOR SHEAR TRANSFER DETAILS: 410.2.1. INTERIOR SHEAR WALL WITH PARALLEL FLOOR FRAMING AT SW6 AND SW4: J,T/ FLFR FLOOR SHEATHING PANEL EDGE NAILING INTO JOIST 5O PERARCH � �, BLOCKING CONNECTION REQUIREMENTS PER 307.7.3 JOIST ALIGNED DIRECTLY OVER WALL BELOW FLANGE NAILING PER SHEARWALL SCHEDULE WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE ( -- SHEAR WALL PER PLAN CALLOUT CAN BE EITHER SIDE OF WALL 410.2.2. PROVIDE ADDITIONAL JOIST OR BLOCKING AT INTERIOR SHEAR WALL WITH PARALLEL FLOOR FRAMING AT SW3 AND SW2 AS FOLLOWS (REQUIREMENTS BELOW ARE IN ADDITION TO ALL REQUIREMENTS OF 410.2.1): T/ ADDITIONAL ROW OF FLOOR SHEATHING PANEL EDGE NAILING INTO PER ARCH , JOIST/BLOCKING 50 I ADDITIONAL JOIST OR BLOCKING FULL LENGTH OF SHEAR WALL -ADDITIONAL ROW OF FLANGE NAILING AT BLOCKING PER SHEARWALL SCHEDULE 410.2.3. INTERIOR SHEAR WALL WITH PERPENDICULAR FRAMING AT SW6 AND SW4: FLOOR SHEATHING PANEL EDGE NAILING INTO BLOCKING LF05 T/ vE� RFARC JOIST BLOCKING FLANGE NAILING PER SHEARWALL SCHEDULE WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE 10 SHEAR WALL PER PLAN CALLOUT CAN BE EITHER SIDE OF WALL 410.2.4. AT INTERIOR SHEAR WALL WITH PERPENDICULAR FRAMING AT SW3 AND SW2, PROVIDE ADDITIONAL ROW OF BLOCKING SIMILAR TO REQUIREMENTS OF 410.2.2 AT PARALLEL FRAMING. 410.2.5. AT INTERIOR EDGE OF FLOOR FRAMING, LSL RIM JOISTS SHALL BE PROVIDED IN LIEU OF TJI JOIST, WITH TOE NAILING AS REQUIRED IN LIEU OF FLANGE NAILING. SEE EXTERIOR SHEAR WALL REQUIREMENTS FOR SIMILAR CONDITIONS. 410.2.6. AT INTERIOR SHEAR WALLS ABOVE THAT DO NOT STACK WITH WALLS BELOW (SIM AT PERPENDICULAR FRAMING BELOW WITH BLOCKING UNDER SHEAR WALL IN LIEU OF JOISTS. REF 307.7.3 FOR BLOCKING DETAILS): SHEAR WALL ABOVE PER PLAN CALLOUT - WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL PEA I i SCHEDULE Ol SILL PLATE NAILING TO JOIST BELOW PER SHEAR WALL 1 SCHEDULE O3 --FLOOR JOIST ALIGNED UNDER WALL ABOVE (ADDITIONAL JOISTS M!n REQUIRED AT SW3 ANS SW2) OR BEAM PER PLAN CALLOUT 410.2.7. EXTERIOR SHEAR WALL WITH PERPENDICULAR FLOOR FRAMING: SHEAR WALL ABOVE PER PLAN CALLOUT SILL PLATE NAILING TO RIM PER SHEAR WALL SCHEDULE [ FOR SHEAR WALL CALLOUT ABOVE WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE Ol PER SHEAR WALL CALLOUT ABOVE T� FLOOR SHEATHING PANEL EDGE NAILING INTO BLOCKING O5 PER ARCH T � f PER SHEAR WALL CALLOUT BELOW I ._ WALL SHEATHING SHALL BE SPLICED OVER RIM WITH WALL SHEATHING PANEL EDGE NAILING lO AS APPLICABLE FOR RESPECTIVE SHEARWALLS RIM JOIST. SIZE AS REQUIRED PER SHEAR WALL SCHEDULE TOE NAILING PER SHEARWALL SCHEDULE WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE () PER SHEAR WALL CALLOUT BELOW SHEAR WALL BELOW PER PLAN CALLOUT 410.2.8. EXTERIOR SHEAR WALL WITH PARALLEL FLOOR FRAMING SHALL BE SIMILAR TO EXTERIOR SHEAR WALL WITH PERPENDICULAR FRAMING NOTE 410.2.7 WITH FLOOR BLOCKING INSTALLED AS REQUIRED PER NOTE 307.7.1 410.2.9. AT OPEN WEB TRUSSES, INTERIOR SHEAR WALL WITH PARALLEL FLOOR FRAMING: (3) 0.131"X2-1/2" NAILS INTO 2X BLOCKING @ 48" O.C. FLOOR SHEATHING PANEL EDGE NAILING INTO JOIST 50 T/ FLFR _ r PE� Rwz�H i -, 2X4 BRACE @ 48" O.C. WITH (3) FACE NAILS TOP AND (3) TOE NAILS BOT -SHEAR TRUSS ALIGNED DIRECTLY OVER WALL BELOW. -" TRUSS SHALL BE DESIGNED FOR DRAG FORCE AS g INDICATED PER PLAN (OR MIN 250 PLF IF NO SPECIFIED) FLANGE NAILING PER SHEARWALL SCHEDULE WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE Ol SHEAR WALL PER PLAN CALLOUT CAN BE EITHER SIDE OF WALL 410.2.10. AT OPEN WEB TRUSSES, INTERIOR SHEAR WALL WITH PERPENDICULAR FLOOR FRAMING SHALL BE SIMILAR TO 410.2.3 WITH TRUSS BLOCKING PROVIDED IN LIEU OF JOIST BLOCKING• TYPICAL TRUSS BLOCKING SHALL BE AS FOLLOWS: � T/PEER > FLOOR SHEATHING PANEL EDGE NAILING INTO BLOCKING 50 PE� Rom+ ,,---TRUSS BLKG SHALL BE PROVIDED OVER ENTIRE LENGTH OF SHEARWALL PICTURE FRAME' BLOCKING WITH 2X4 TOP AND BOT PLATE AND 2X4 CRIPPLE -- _----"PICTURE STUDS ADJACENT TO TRUSSES. SHEATHING AND NAILING O SHALL MATCH -. REQUIREMENT FOR SHEAR WALL BELOW �.R�0.131"X3" NAILS FROM BLOCKING TO TRUSS VERT @6"O.0 (MIN 4) EA SIDE T/P PER L ARCH s-� OPEN WEB TRUSS PER PLAN Y SILL PLATE NAILING BLOCKING TO TOP PLATE PER SHEAR WALL SCHEDULE O3 SHEAR WALL BELOW PER PLAN CALLOUT O ELEVATION ID tx FLOOR SHEATHING PANEL EDGE NAILING INTO BLOCKING 5 T/FLFR PANEL EDGE NAILING FOR SHEATHING AT BLOCKING PER SH AR WALL PE� RR°' SCHEDULE M "PICTURE F E" BLOCKING W/ SHEATHING SILL PLATE NAILING BLOCKING TO TOP PLATE PER SHEAR �T/vL r WALL SCHEDULE 3O OVER ARCH BLOCKING SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE WALL SHEATHING FrANEL EDGE NAILING PER SHEAR WALL SCHEDULE Ol OPEN WEB FLOOR TRUSSES SECITON "A" 410.2.11. SHEAR CONNECTION REQUIREMENTS AT OPEN WEB TRUSSES AT EXTERIOR SHEAR WALLS WITH PERPENDICULAR FRAMING. AT SW3 AND SW2 CALLOUT PROVIDE 3X TRUSS BAND. SHEAR WALL ABOVE PER PLAN CALLOUT SILL PLATE NAILING TO RIM PER SHEAR WALL SCHEDULE O3 FOR SHEAR WALL CALLOUT ABOVE VEFLFR ' WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL vEY R SCHEDULE OPER SHEAR WALL CALLOUT ABOVE FLOOR SHEATHING PANEL EDGE NAILING INTO BLOCKING OS PER SHEAR WALL CALLOUT BELOW EXTEND WALL SHEATHING BELOW TO TRUSS BAND AND PROVIDE WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE Ol OPEN WEB FLOOR TRUSSES WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL �r/vL SCHEDULE [ PER SHEAR WALL CALLOUT BELOW PERiARCH �/ SHEAR WALL BELOW PER PLAN CALLOUT - -A - 410.2.12. SHEAR CONNECTION REQUIREMENTS AT OPEN WEB TRUSSES AT EXTERIOR SHEAR WALLS WITH PARALLEL FRAMING. (3) 0.131"X2-1/2" NAILS INTO 2X BLOCKING @ 48" O.C. SHEAR WALL ABOVE PER PLAN CALLOUT SILL PLATE NAILING TO RIM PER SHEAR WALL SCHEDULE T/FLFR L O3 FOR SHEAR WALL CALLOUT ABOVE PE� R^�H �- - WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE Ol PER SHEAR WALL CALLOUT ABOVE 1 FLOOR SHEATHING PANEL EDGE NAILING INTO BLOCKING �1 \ ( PER SHEAR WALL CALLOUT BELOW 1 EXTEND WALL SHEATHING BELOW TO T/LADDER TRUSS AND PROVIDE WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE Ol 'LADDER" TYPE OPEN WEB FLOOR TRUSSES AT PERIMETER �r/PL � 2X4 BRACE @ 48" O.C. WITH (3) FACE NAILS TOP AND (3) PER RRCCH TOE NAILS BOT WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL _SCHEDULE (D PER SHEAR WALL CALLOUT BELOW SHEAR WALL BELOW PER PLAN CALLOUT 411. FORCE TRANSFER AROUND OPENINGS 411.1. WHERE HORIZONTAL STRAPS ARE SHOWN ON THE SHEAR WALL PLAN ACROSS AN OPENING, THE OPENING IS INCORPORATED WITHIN THE SHEAR WALL ASSEMBLY AS A FORCE -TRANSFER AROUND OPENING (FTAO) CONDITION. FRAMING, STRAPPING, AND NAILING REQUIREMENTS FOR FTAO ASSEMBLIES SHALL BE PER THE FORCE -TRANSFER AROUND OPENING DETAILS AS FOLLOWS: 411.1.1. AT OPENINGS WITH CRIPPLE WALLS ABOVE AND BELOW OPENING: HEADER PER PLAN DOUBLE 2X BLOCKING AT STRAP _ CONTINUOUSLY SHEATHED SHEAR WALL AROUND �' I �� OPENING PER PLAN SHEAR WALL CALLOUT II EXTEND STRAP PAST OPENING AS INDICATED * PER PLAN. IF NOT CALLED OUT, MIN 4'-0" OR TO END OF WALL WHICHEVER IS SHORTER. TOP AND BOT, BOTH SIDES OF OPENING PROVIDE SHEAR WALL PANEL EDGE NAILING I� AT BOTH JACK AND KING STUDS. BOTH SIDES OF OPENING OPENING PER ARCH DOUBLE 2X BLOCKING AT STRAP DOUBLE SILL PLATE AT STRAP 411.1.2. AT OPENINGS WITH CRIPPLE WALLS ABOVE OPENING ONLY: HEADER PER PLAN DOUBLE 2X BLOCKING AT STRAP CONTINUOUSLY SHEATHED SHEAR WALL AROUND �- OPENING PER PLAN SHEAR WALL CALLOUT � EXTEND STRAP PAST OPENING AS INDICATED PER PLAN. IF NOT CALLED OUT, MIN 4'-0" OR TO END OF WALL WHICHEVER IS SHORTER. TOP AND BOT, BOTH SIDES OF OPENING \ PROVIDE SHEAR WALL PANEL EDGE NAILING AT BOTH JACK AND KING STUDS. BOTH SIDES OF OPENING OPENING PER ARCH F j4, /* *1 .ALIAKSEI.PATSEVICH I , , .............................. 130521 """"J "•". ONA L O 0 Z Z W Z C� W Z W z Z 00W J O p1 tO U x z Luz Lu LL- ,_, z Wiz 0- Lu O ~ � J U JG O Lu 7 F- OL. Oi 00 N REVISIONS 0 DATE Ln N �O 0 . PROJECT NAME 101 CROSS CREEK GARAGE ADDITION PROJECT ADDRESS 101 CROSS CREEK DR GRAPEVINE, TX PROJECT NUMBER S26129 CHECKED BY - AP SHEET DATE - 05/04/2026 z _O Ln Lu 0 SCALE 24X36 SHEET:1/2"=V-0" Lu J 0 Z Q J Q W 0 Lu F- 0 2-1 9 co J Q J? I L 2 Ln SHEAR WALL PLAN NOTES U) SW6 I I I I 1 <D I I Ln I 1 FOR TYPICAL SHEAR WALL INSTALLATION AND STANDARD DETAIL REQUIREMENTS, REFER TO THE GENERAL SHEAR WALL NOTES (GN401) AS FOLLOWS: SHEATHING AND FRAMING MATERIALS - SEC. 402 SHEAR WALL CONSTRUCTION AND NAILING - SEC. 403 HOLDOWNS AND OVERTURNING RESTRAINT - SEC. 404 PORTAL FRAMES - SEC. 405 SPECIAL / PREFABRICATED SHEAR WALL PANELS - SEC. 406 SHEAR WALL SCHEDULE - NOTE 409 STANDARD SHEAR TRANSFER DETAILS - SEC. 410 FORCE TRANSFER AROUND OPENINGS (FTAO) - SEC. 411 SEE ALSO: GENERAL STRUCTURAL NOTES (GN100) AND GENERAL FRAMING NOTES (GN301) FOR ADDITIONAL MATERIAL, FASTENER, AND FRAMING REQUIREMENTS. WHERE SPECIFIC NOTES OR DETAILS ARE SHOWN ON THE PLANS, THOSE SHALL GOVERN. ALIAKSEI PATSEVICH .A. .•.130521 `1\��ONAL ENS~ W Q 0 Z z*a o W z w ZWz Z z 0 0 Lu J M Ql 57 boo �p U u zt� x Lu w Lu� z z > '-' _j 0 Lu o- z w x O x> o w CID (f) Q L CL Q a rl 00 CV u') N REVISIONS DATE BY PROJECT NAME 101 CROSS CREEK GARAGE ADDITION PROJECT ADDRESS 101 CROSS CREEK DR GRAPEVINE, TX PROJECT NUMBER S26129 CHECKED BY - AP SHEET DATE - 05/04/2026 �,p SCALE 24X36 SHEET:1/2"=1'-0" SW6 � � z J J Q ROOF DC Q Lu 2Nn FLOOR = U) 1ST FLOOR/ z 0 .--i FOUNDATION p 0 L.L. LEVEL KEY ry U w Cf) w L.L SHEAR WALL PLAN NOTES Ln s% SW6 et f SW6 � FOR TYPICAL SHEAR WALL INSTALLATION AND STANDARD DETAIL REQUIREMENTS, REFER TO THE GENERAL SHEAR WALL NOTES (GN401) AS FOLLOWS: SHEATHING AND FRAMING MATERIALS — SEC. 402 SHEAR WALL CONSTRUCTION AND NAILING — SEC. 403 HOLDOWNS AND OVERTURNING RESTRAINT — SEC. 404 PORTAL FRAMES — SEC. 405 SPECIAL / PREFABRICATED SHEAR WALL PANELS — SEC. 406 SHEAR WALL SCHEDULE — NOTE 409 STANDARD SHEAR TRANSFER DETAILS — SEC. 410 FORCE TRANSFER AROUND OPENINGS (FTAO) — SEC. 411 SEE ALSO: GENERAL STRUCTURAL NOTES (GN100) AND GENERAL FRAMING NOTES (GN301) FOR ADDITIONAL MATERIAL, FASTENER, AND FRAMING REQUIREMENTS. WHERE SPECIFIC NOTES OR DETAILS ARE SHOWN ON THE PLANS, THOSE SHALL GOVERN. ALIAKSEI PATSEVICH .A. .•.130521 `1\��ONAL ENS~ W Q 0 Z z*a o W z w z ZW Z z 00W J M Ql 57 boo �p U u zt� x w � w w � z z > '—' _j 0 Lu o- z w x O x> ow CID (f) Q L CL Q a rl 00 CV u') N REVISIONS DATE BY PROJECT NAME 101 CROSS CREEK GARAGE ADDITION PROJECT ADDRESS 101 CROSS CREEK DR GRAPEVINE, TX PROJECT NUMBER S26129 CHECKED BY - AP SHEET DATE - 05/04/2026 SCALE 24X36 SHEET: 1/2"=1'-0" z Q J J Q ROOF Q Lu U) 2ND FLOOR rC O N 1ST FLOOR/ .--i FOUNDATION z J o L.L a U') LEVEL KEY v z w 0 w w Cn _ 5/4/26, 11.55 AM INIG_1977.jpeg z = xv4cu 7 o - U v'rs . I •� &S wrw*aw a --to—As iw https-//mai1.google.com/mai1/u/0/?tab=rm&ogbignbox?projector=1 1 1 V -I II II II II II II II II II II II II II II II II II II II II II II II II II II I� I' II II II II II II II II II II II II II II II II II II II II II II II II EXSITING STAIRS f OPEN RAIL 0 EXISTING EXISTING GARAGE GI'M VI' CEILING VAULTED CEILING 0 WATER NEATER O ® 20' AFF. ''EXISTING'' =`I=LC0fzR FLAN [ 1 � E SITING .9 O AIRS in •�-1�'-6' 2'-10' NEW WALL— . ............... ............... EXISTING GARAGE VI' CEILING 0 i 0 III L II FL C0f;R FLAN 1/4" =1'0' WALL LEGEND NEW WALL EXISTING WALL TO REMAIN CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 07/07/2026 9:13:43 AM BY: KELLY TAFT TSBPE: I-3971 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY ALL CHANGES MUST BE APPROVED. 8'•8' i i �t i EXSITING 28' HIGH PONY WALL EXSITING 26' HIGH PONY WALL / lo' rt - 00,................................ d'-V L.� NEW ATTIC A k EXSITING 28' HIGH PONY WALL ATTIC EXSITING 28' HIGH PONY WALL II XISTII C-T` =SECC VD FLCO �=LAN 1/4 =1'0 i i i i s z 16 1L O p S C ONE FLOC FL AN NOTES: -CONTRACTOR TO VERIFY ALL DIMENSIONS ON 51TE -CONTRACTOR TO COORDINATE REMOVAL OF ANY INTERIOR OR EXTERIOR LOAD BEARING WALLS WITH STRUCTURAL ENGINEER PRIOR TO ANY ON 51TE DEMO. DOOR 5G�4EDULE MARKQTY. 51ZE DESCRIPTION 1 1 218"x61511 EXT.S.C. WINDOW &C�4EDULE MARKQTY. SIZE DESCRIPTION A 1 2 ITWIN 3'0"x5'0' I 6-H.D.L. RECEIVED: 5/08/2026 26-001641 101 CROSS CREEK DR ADDING DORMER'S TO DETACHED GARAGE ------------------- I I I I CU 26-16 I I I I I I ATTIC CEILING CANNOT EXCEED 67" IN HEIGHT SLEEPING QUARTERS PROHIBITED [ _ 1 r I 1 I lI I I 1 1 I I 1 1 1 ,JL l,J rr III III _ GCCNE) L 0T I CAL �=L AN 1/411= 11011 ELECTRICAL SYMBOLS 110V DUPLEX OUTLET RECE55ED GE IL ING MOUNTED LIGHT 10 NOTE: THE GENERAL CONTRACTOR AND USE ALL 5U5GONTRACTORS SHALL REVIEW THE All documents here attached are FULL CONTENT OF THE PLANS FOR Exurb sywol o,, o� gne . The D15GREPANGIE5 AND 01 115510NS PRIOR TO and aI o� �o�lenieprep re p spared COMMENCEMENT OF WOR< by the Designer, and the Designer's office are instruments of service. The Designer shall be deemed the author of these documents and retains all statutory, ALL CHANGES REQUIRE law, and o reserved rights including Copyright. The Deslgnar's Design Drawings, SpeelFteations and all other APPROVAL O F REVISED documam Designer the and (or) the Designer's officeshelltnot bear�� bV the Owner (c%ft) or others on any PLANS other pro, —tI t, plcluding additions or Ifieallons to this projeet or For completion of this project by others, without permission In writing From the Designer. No part of the above merltiorled documents may be reproduced without similar permission from the Designer. APPROVED PLANS SHALL BE The Designer assures no Ilabllity for any structure built from these KEPT ON J O B S I T E AT ALL TIMES purchaser, plane. af builder, ore soar conttrre or must verify all dimensions, verify compliance with all building codes, ` and Incorporate site conditions. 1 EXURB STUDIO, LLG CONTRACTOR SHALL CALL FOR INSPECTIONS: 'oI=EYNE,,iTBE66051ND N. (817) 410 -3 010 PHONE: 21 -3580 EMAIL: IWOOOsEXEXURBSTUD IO.GOM CONTRACTOR REGISTRATION WILL BE REVOKED UPON PERMIT EXPIRATION. CONSTRUCTION HOURS 7:00 A.M. — 7:00 P.M. MONDAY — SATURDAY ONLY SEPERATE PLUMBING, MECHANICAL, ELECTRICAL AND SIGN PERMITS SHALL BE REQUIRED. SPECIAL NOTE PROVIDE SAFETY GLAZINGS AS REQUIRED PER SECTION 308 AND EMERGENCY ESCAPE AND RESCUE OPENINGS PER SECTION 310 OF THE INTERNATIONAL RESIDENTIAL CODE IIN W II _ �RCC)F: FL AN 1 /4' _— 1 10 11 u FM0 U 0 Ln0 In 10 j W 3 3 LU Q Y LU v' X LU I � U 0 REVISIONS 1. 2. 3. 4. DATE: 2/16/26 PRAWN EXS CHECK BY- EXS PROJECT NO. WARE CzARAGE A1.1 g'1° PLATE CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 07/07/2026 9:20:46 AM BY: KELLY TAFT TSBPE: 1-3971 SHINGLES 6 4:12 TO MATCH EXISTING C NL� F RCN T ELEVATICN 1/4" =1'0" SIDING TO MATCH EXISTING 2 10 9'1" PLATE F.F. 12 4 i iz 4 12 � 4 .. N UJ LEFT ELEVATION 1/4" =1'0" F.F. NELJ i�k�T ELEVATION 1/4" =1'0" SIDING TO MATCH EXISTING 9'1" PLATE NOTE: TI4E GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL REVIEUJ THE FULL CONTENT OF THE PLANS FOR DISCREPANCIES AND OMISSIONS PRIOR TO COMMENCEMENT OF UJOR< i USE All documents here attached are Copyrighted 2025 by Exurb Studio, Designer. The Deelgn, 5pecIficattons, Drawings and all other documents prepared by the Designer, and (or) the Designer's office are Instruments of service. The Designer shell be deemed the author of these documents and retains all statutory, common law, and other reserved rights Including Copyright. The Designer's Design, Drawings, Specifications and all other documents prepared by the Designer and (or) the Designer's office shall not be reused by the Owner (client) or others on any other project, Including additions or modifications to this project or for completion of this project by others, without permission In writing from the Designer. No part of the above mentioned documents may be reproduced without similar permission from the Designer. The Designer assumes no Ilability for any structure built from these plane. Before construction, the purchaser, builder, or contractor must verlfy all dimensions, verlfy compliance with all building codes, ` and Incorporate site conditions. l EXURB STUDIO, LLc 1038 MEADOW BEND LOOP N. GRAPEVINE, TX 16051 PHONE: 214-619-3580 EMAIL: IWOOEXURBSTUD IO.COM 0 U 0 In X W 3 3 z t Q LU Y X U w w LU CD (3 Z } LU U 0 � REVISIONS 1. 2. 3. 4. 1 < DATE: 2/16/26 DRAWN BY: EXS CHECK BY: EXS PROJECT NO. WARE GARAGE BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY ALL CHANGES MUST BE APPROVED. SHE NurrBER 1.2 GENE R L GONeTRI�CT I ON NOTES, 1. OWNER / CLIENT RESPONSIBILITIES: REFERENCE IS MADE THROUGHOUT THESE GENERAL NOTES TO RESPONSIBILITIES AND STANDARDS OF CARE TO BE FULFILLED BY THOSE PROVIDING SERVICES IN THE DEVELOPMENT AND CONSTRUCTION OF THIS PROJECT. OWNER / CLIENT SHALL BE RESPONSIBLE FOR ADHERENCE TO THOSE REQUIRMENTS BY THE OWNER, BUILDER, GENERAL CONTRACTOR, SUBCONTRACTORS AND OTHER PROFESSIONAL CONSULTANTS NOT RETAINED BY THE DESIGNER. 2. PERMIT SET. THIS SET OF PLANS IS SUFFICIENT TO OBTAIN BUILDING PERMIT, HOWEVER, ALL MATERIALS AND METHODS OF CONSTRUCTION NECESSARY TO COMPLETE THE PROJECT ARE NOT NECESSARILY DESCRIBED. THE PLANS DELINEATE AND DESCRIBE ONLY LOCATIONS, DIMENSIONS, TYPES OF MATERIALS AND GENERAL METHODS OF ASSEMBLING OR FASTENING. SPECIFICATION OF PARTICULAR PRODUCTS OR MATERIALS IS TO BE COORDINATED BY THE CONTRACTOR AND APPROVED BY THE OWNER. THE IMPLEMENTATION OF THESE PLANS REQUIRES AN OWNER / CLIENT / CONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE APPLICABLE BUILDING CODES AND METHODS OF CONSTRUCTION SPECIFIC TO THIS PRODUCT TYPE AND TYPE OF CONSTRUCTION. 3. BUILDING MAINTENANCE: THE EXPOSED MATERIALS USED IN THE CONSTRUCTION OF THIS PROJECT WILL DETERIORATE AS THE COMPLETED PROJECT AGES UNLESS PROPERLY AND ROUTINELY MAINTAINED. THE OWNER / CLIENT / CONTRACTOR SHALL PROVIDE OR CAUSE THE DEVELOPMENT OF A PLAN TO KEEP THESE EXPOSED MATERIALS PROTECTED AND MAINTAINED THROUGH COMPLETION OF THIS PROJECT. 4. ALL CONSTRUCTION SHALL GOMPLY WITH THE MOST STRINGENT REQUIREMENTS OF ALL CURRENT APPLICABLE CITY, COUNTY, STATE AND FEDERAL LAUDS, RULES, CODES, ORDINANCES AND REGULATIONS. IF THE GENERAL CONTRACTOR OR ANY SUBCONTRACTOR PERFORMS ANY WORK IN CONFLICT WITH THE ABOVE MENTIONED LAUDS, RULES, CODES, ORDINANCES AND REGULATIONS, THEN THE CONTRACTOR IN VIOLATION SHALL BEAR ALL COSTS OF REPAIR ARISING OUT OF THE NON -CONFORMING WORK. 5. PERMITS: THE GENERAL BUILDING PERMIT AND PLAN CHECK SHALL BE SECURED AND PAID FOR BY THE OWNER / CLIENT. ALL OTHER PERMITS SHALL BE SECURED AND PAID FOR BY THE SUBCONTRACTOR DIRECTLY RESPONSIBLE. ro. NAMED PRODUCTS: THE DESIGNER MAKES NO GUARANTEE FOR THE PRODUCTS IDENTIFIED BY TRADE NAME OR MANUFACTURER. 1. SCOPE: THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL FURNISH ALL LABOR, EQUIPMENT AND MATERIAL INDICATED ON THE PLANS AND REASONABLY INFERRED OR REQUIRED BY THE APPLICABLE CODES. 8. SUBSTITUTION: THE GENERAL CONTRACTOR AND ANY SUBCONTRACTORS SHALL NOT MAKE ANY STRUCTURAL SUBSTITUTIONS OR CHANGES WITHOUT PRIOR WRITTEN AUTHORIZATION FROM THE STRUCTURAL ENGINEER. 9. CHANGES: ANY ADDITION, DELETION OR CHANGE IN THE SCOPE OF THE WORK DESCRIBED BY THE PLANS SHALL BE BY WRITTEN CHANGE ORDER ONLY. ANY APPROVAL FROM THE BUILDING OFFICIAL FOR A CHANGE IN THE WORK SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 10. INTENTION: THE GENERAL CONTRACTOR SHALL ENSURE THAT ALL LABOR, MATERIALS, EQUIPMENT AND TRANSPORTATION SHALL BE INCLUDED IN THE WORK FOR THE COMPLETE EXECUTION OF THE PROJECT. THE DESIGNER SHALL NOT BE RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION. 11. REVIEW OF DRAWINGS: THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL REVIEW THE FULL CONTENT OF THE PLANS FOR DISCREPANCIES AND OMISSIONS PRIOR TO COMMENCEMENT OF WORK. THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL BE RESPONSIBLE FOR ANY WORK NOT IN CONFORMANCE WITH THE PLANS OR IN CONFLICT WITH ANY CODE. 12. USE OF DRAWINGS: DIMENSIONS TAKE PRECEDENCE OVER SCALED MEASUREMENTS. DETAILS AND SECTIONS ON THE DRAWINGS ARE SHOWN AT SPECIFIC LOCATIONS AND ARE INTENDED TO SHOW GENERAL REQUIREMENTS THROUGHOUT. DETAILS NOTED "TYPICAL" IMPLY ALL LIKE CONDITIONS TREATED SIMILARLY, UNLESS NOTED OTHERWISE. THE BUILDING DETAILS SHOWN ARE INTENDED TO FURTHER ILLUSTRATE THE VISUAL DESIGN CONCEPT AND THE MINIMUM RECOMMENDED WEATHER PROTECTION FOR THE PROJECT. BUILDING CODE REQUIREMENTS, STRUCTURAL CONSIDERATIONS, TRADE ASSOCIATION MANUALS AND PUBLICATIONS AND PRODUCT MANUFACTURER'S WRITTEN INSTRUCTIONS SHALL ALSO BE CONSIDERED IN ORDER TO COMPLETE THE CONSTRUCTION OF THE DETAILS, AND IN SOME CASES MAY SUPERSEDE THE DETAILS. 13. APPROVED DRAWINGS: THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK BETWEEN THE DIFFERENT SUBCONTRACTORS AND REQUIRING ALL SUBCONTRACTORS TO USE THE MOST CURRENT BUILDING DEPARTMENT APPROVED SET OF CONSTRUCTION PLANS. 14, CLEAN UP: ALL TRADES SHALL, AT ALL TIMES, KEEP THE PREMISES FREE FROM ACCUMULATION OF WASTE MATERIALS OR RUBBISH CAUSED BY THEIR WORK. SUBCONTRACTORS SHALL REMOVE ALL RUBBISH, TOOLS, SCAFFOLDING AND SURPLUS MATERIALS AND LEAVE THE JOB IN BROOM -CLEAN CONDITION. ALL FIXTURES, EQUIPMENT, GLAZING, FLOORS, ETC., SHALL BE LEFT CLEAN AND READY FOR OCCUPANCY UPON COMPLETION OF THE PROJECT. 15. STORAGE OF MATERIALS: THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR STORING THE MATERIALS ON THE SIT ACCORDING TO MATERIAL SUPPLIER'S OR MANUFACTURER'S INSTRUCTIONS. THE MATERIALS SHALL BE KEPT SECURE AND PROTECTED FROM MOISTURE, PESTS, AND VANDALS. ANY LOSS ARISING OUT OF MATERIALS STORED AT THE SITE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR OR SUBCONTRACTORS WHO STORED THE DAMAGE OR LOST MATERIALS. 1(o, THE GENERAL CONTRACTOR SHALL COORDINATE THE WORK WITH MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ALL NECESSARY OPENINGS AND PENETRATIONS THROUGH WALLS, CEILINGS AND FLOORS. USE All documents here attached are Copyrighted 2025 by Exurb Studio, Designer. The ROU C RPLNTR�' DEMOLITION / CON&TRACTION NOTES and all other dlocuments prepared by the Designer, and (or) the Deslgner'e office are Instruments of r service. The Designer shall be 1. FR M ING" deemed the author of these f-+ documents and retains all statutory, ed A. STUD UJALLS PER APPLICABLE BUILDING CODE. 1. THE INTENT OF THE DEMOLITION PLANS IS TO SHOW THE common law, i 9 p right7hee Including FULL HEIGHT UJALLS SHALL HAVE CONTINUOUS STUDS FROM Designer's Design, Drawings, GENERAL NATURE OF THE DEMOLITION SCOPE. THE documents pre and all other documents prepared by the BOTTOM TO TOP PL ATE. GENERAL CONTRACTOR 15 RE SPONS 1 BL E FOR VISITING THE office sh and (or) the Designer's th office shell not be reused by the B. CEILING JOISTS: PER APPLICABLE BUILDING CODE. JOB SITE AND VERIFYING THE EXISTING CONDITIONS 4 °erprC1e"t' or includingang USE SOLID BRIDGING. orbs project, Including project o DIMENSIONS. THE GENERAL CONTRACTOR SHOULD NOTIFY ns or r'com catlons to this project or far completion of this project by C. BACKING: PROVIDE BACKING AT ALL PENDANT OR SIGNATURE DESIGN STUDIO IMMEDIATELY OF ANY others,rwithout Designer. No p In writing gne. part of the SURFACE -MOUNTED ELECTRICAL FIXTURES, RAILS, GRAB BARS, DISCREPANCIES. aberepodlu�aho �imilarr BATH ACCESSORIES, ETC. permission from the Designer. bilitq D. F1RE STOPPING: PER APPLICABLE BUILDING CODE. 2. COORDINATE AND VERIFY WITH THE OWNER ALL ITEMS TO for ang Designer assumes fromno these for an structure built from these E. STUD UJALLS: PER APPLICABLE BUILDING CODE. ALL he purchaser, builder, contractor BE SALVAGED PRIOR TO DEMOLITION. ION. ustvee, bu"der, or ns,vec STUDS TO HAVE FULL BEARING ON PLATE. ALL STUDS TO must veify all all building verify compliance with all building codes, ` and Incorporate site conditions. BE fro" O.G. UNLESS NOTED OTHERWISE. STUDS TO BE SIZED 3. GENERAL CONTRACTOR IS TO MAINTAIN A SEPARATIONEXURB I LLC PER REQUIREMENTS OF BUILDING CODE. BETWEEN AREAS WITHIN THE SCOPE OF WORK AND AREAS 1038ME MEADUDIO,OW EN 1038 MEADOW BEND LOOP N. F. USE CONTINUOUS, FULL HEIGHT STUDS IN ACCORDANCE OUTSIDE OF THE SCOPED. OF WORP 0NE:v2r114E Tx 9,35801 WITH THE HIGHEST STANDARD OF CONSTRUCTION AND EMAIL: IWOOEXURBSTUDIO.COM FRAMING PRACTICES. 4. CAUSE NO DAMAGE TO EXISTING CONSTRUCTION TO REMAIN, G. ALL ANGLED WALLS TO BE 45 DEGREES UNLESS NOTED TAKE CARE NOT TO ENCROACH ON ADJACENT OCCUPIED OTHERWISE. AREAS OR AREAS NOT WITHIN THE SCOPE OF WORK, H. BUILT UP ROOFS, WATERPROOF BALCONY DECKS AND PROTECT ALL EXISTING FINISHES, DOORS, FRAMES, ETC. EXTERIOR HORIZONTAL AREAS ARE TO FRAMED WITH SLOPE WHICH AREA TO REMAIN. TO ENSURE WATER DRAINAGE WITHOUT PONDING. I. PROVIDE CRICKETS AS INDICATED AND AS NECESSARY 5. USE ALL MEANS NECESSARY TO PREVENT THE SPREAD OF FOR PROPER WATER DRAINAGE AND TO REDIRECT CHANNELED DUST TO ADJACENT AREAS. OR RUNOFF WATER AWAY FROM VERTICAL SURFACES. J. PROVIDE BLOCKING WHERE REQUIRED TO PROVIDE (o. CONDUCT DEMOLITION OPERATIONS 4 THE REMOVAL OF UNIFORM SURFACES WHERE FLUSH JOISTS AND BEAMS ARE DEBRIS TO ENSURE MINIMUM INTERFERENCE WITH STREETS, DIFFERENT DEPTHS. WALKS, $ OTHER ADJACENT OCCUPIED OR USED FACILITIES. K. USE MITERED JOINTS AT FASCIA SPLICES. COMPLY WITH LOCAL JURISDICTION REQUIREMENTS FOR L. ALL DIMENSIONS ARE GIVEN TO CENTER OF FRAMING, RECYCLING AND TREATMENT OF ITEMS TO BE RECYCLED. UNLESS OTHERWISE NOTED. 0 i. DISPOSE OF ALL DEMOLISHED OR REMOVED MATERIALS 0 LEGALLY OFF THE SITE. COMPLY WITH ALL LOCAL HAULING '0 DISPOSAL REQUIREMENTS. iph, 0 F In FLOOR PLAN NOTE 5 8. EXURB STUDIO HAS NO KNOWLEDGE OF AND SHALL NOT BE to HELD LIABLE FOR ANY ASBESTOS OR OTHER HAZARDOUS I. ALL GAS OR WOOD -BURNING FIREPLACES WITHIN A DWELLING UNIT SHALL MATERIALS ON JOBSITE. THE CONTRACTOR SHALL X W COMPLY WITH THE INTERNATIONAL RESIDENTIAL CODE AND LOCAL AMENDMENTS. IMMEDIATELY ISOLATE THE AFFECTED AREA IF ASBESTOS 2. SMOKE DETECTORS SHALL BE INSTALLED AT LOCATIONS REQUIRED BY OR OTHER HAZARDOUS MATERIAL ARE DISCOVERED THE INTERNATIONAL RESIDENTIAL CODE AND SHALL RECEIVE THEIR PRIMARY DURING CONSTRUCTION. NOTIFY OWNER FOR FURTHER 3 POWER FROM BUILDING WIRING AND SHALL BE EQUIPPED WITH A BATTERY BACK UP. INSTRUCTION BEFORE PROCEEDING WITH OTHER WORK, 3. UNDER NO CIRCUMSTANCES IS THE USE OF WATER RESISTANT GYP. BD. "GREEN BOARD" AS BACKING FOR TILE OR WALL PANELS IN ANY POTENTIALLY 9. MAINTAIN EXISTING UTILITIES TO REMAIN IN SERVICE AND "WET" AREA TO BE USED. USE ONLY PANELS RATED FOR MOISTURE $ MOLD PROTECT AGAINST DAMAGE DURING DEMOLITION RESISTANCE. SHOWER STALLS SHALL BE FURNISHED WITH A HARD, NON ABSORBENT OPERATIONS. MATERIAL. 4. PROVIDE A MINIMUM 30"x22" ATTIC ACCESS OPENING WITH A MINIMUM HEADROOM 10. UPON COMPLETION, CLEAN THE ENTIRE AREA OF CLEARANCE OF 30" WHEN MECHANICAL EQUIPMENT IS INSTALLED IN THE ATTIC SPACE. DEMOLITION TO A TIDY, UNIFORM CONDITION REMOVING ALL THE OPENING SHALL BE LOCATED IN A HALLWAY, CORRIDOR OR OTHER READILY DEBRIS, DUST PARTITIONS 4 ASSOCIATED MATERIALS USED ACCESSIBLE LOCATION PER THE INTERNATIONAL RESIDENTIAL CODE. DURING THE DEMOLITION. CLEAN ALL AREAS IMPACTED BY 5. WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO RESIST DISPLACEMENT, THE DEMOLITION, INCLUDING BUT NOT LIMITED TO, ADJACENT STRAPPING SHALL BE AT POINTS WITHIN THE UPPER 3 AND LOUDER 3 OF IT'S VERTICAL OCCUPIED AREAS AND AREAS NOT WITHIN THE SCOPE OF DIMENSION. AT THE LOUDER POINT, MAINTAIN A MIN OF 4" CLEARANCE ABOVE THE WORK. C WATEiRHEATER CONTROLS. (o. GAS WATER HEATERS AND FURNACES SHALL BE LOCATED ON A RIGID RAISED 11, COMPLY WITH ALL STANDARD LOCAL, NATIONAL, STATE AND PLATFORM A MINIMUM OF 18" HIGH. FEDERAL SAFETY REQUIREMENTS FOR i. SAFETY GLAZING TO BE PROVIDED AT THE FOLLOWING AREAS: DEMOLITION/CONSTRUCTION. A. SLIDING OR SWINGING DOORS 12. THE INTENT OF THESE DRAWING& HEREIN IS TO REPRESENT A B. TUB AND OR SHOWER ENCLOSURES AND GLAZING IN WALLS LESS THAN (00" COMPLETE WORKING SYSTEM. ALL CONTRACTORS SHALL BE u Y X ABOVE THE STANDING SURFACE OF TUBS OR SHOWERS. RESPONSIBLE FOR PROVIDING AND INSTALLING ALL C. GLAZING WITHIN 24" OF THE SWING OF A DOOR. COMPONENTS NECESSARY TO PROVIDE THE DESIGN INTENT, Q tx uj D. GLAZING IN WALLS ENGLOSING STAIRWAY LANDINGS OR WITHIN 5' OF THE WHETHER SHOWN OR NOT ON THE DRAWINGS. %5 C } BOTTOM AND TOP OF STAIRWAYS WHERE THE BOTTOM EDGE OF GLASS IS LESS THAN UJ &0" ABOVE THE WALKING SURFACE. (L E. GLAZING WITHIN 18" OF THE FLOOR. �3 U F. ANY INDIVIDUAL PANE GREATER THAN S SQ.FT. ELECTRICAL NOTES 1. ALL CONVENIENCE OUTLETS WITH SWITCHES TO BE SWITCHED AT TOP ONLY, 2. ALL SUJITCHES TO BE 4'-(c>" ABOVE FINISH FLOOR TO CENTERLINE OF SWITCH UNLESS OTHERWISE NOTED. 3, ALL CONVENIENCE OUTLETS ARE 1'-0" ABOVE FINISH FLOOR TO CENTERLINE OF OUTLET UNLESS OTHERUJ15E NOTED. EXCEPTION - LOCATE CONVENIENCE OUTLETS HORIZONTALLY UNDER WINDOWS 4" ABOVE FINISHED FLOOR 4. ALL BRACKET FIXTURES TO BE AT ABOVE FINISH FLOOR TO CENTER OF FIXTURE. 5, SMOKE DETECTORS SHALL BE LOCATED WITHIN 12" OF THE HIGHEST POINT ON THE CEILING. (o. VERIFY LOCATION OF ALL RECEPTACLES FOR APPLIANCES WITH MANUFACTURER'S SPECIFICATIONS. i. ELECTRICAL OUTLET BOXES TO BE SEPARATED A MAXIMUM OF 12'-0" AND ARE TO COMPLY WITH THE NATIONAL ELECTRICAL CODE AND LOCAL CODES. ELECTRICAL OUTLET BOXES TO BE SEPARATED 24" HORIZONTALLY ON ALL PARTY WALLS. G.F.I. CIRCUIT TO BE PROVIDED AT ALL LOCATIONS WHERE REQUIRED BY CODE. CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 07/07/2026 9:20:53 AM BY: KELLY TAFT TSBPE: 1-3971 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY ALL CHANGES MUST BE APPROVED. 1 fR,EVISIONS oir 3. 9 � C DATE: 2/16/26 PRAWN 5 EXS CHECK BY: EXS PROJECT NO. WARE GARAGE SHEET NUMBER 1-1. THE GENERAL CONTRACTOR SHALL VERIFY ALL PROJECT SITE CONDITIONS AND RELATED DIMENIONS. STANDARD CONSTRUCTION NOTES A2 101 CROSS C SEEK GA SAG =.AD DI-IO V F j4, ........................... ALIAKSEI PATSEVICH CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 07/07/2026 9:20:59 AM BY: KELLY TAFT TSBPE: 1-3971 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY ALL CHANGES MUST BE APPROVED. GN002. ABBREVIATIONS ABBREVIATION DESCRIPTION FRT FIRE RETARDANT TREATED RCSC RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS @ AT FS FAR SIDE RD ROOF DRAIN = EQUAL FT FOOT REC RECOMMENDATIONS # POUNDS (LBS.) FIG FOOTING REF REFERENCE OR REFER A.B. OR AB ANCHOR BOLT GA GAUGE REINF REINFORCEMENT A/C OR AC AIR CONDITIONING GALV GALVANIZED REQ'D OR REQD REQUIRED ABV ABOVE GB GRADE BEAM REQ'S OR REQS REQUIREMENTS ACI AMERICAN CONCRETE INSTITUTE GC GENERAL CONTRACTOR REQ'T OR REQT REQUIREMENT ADDL ADDITIONAL GEOTECHNICAL ENGINEER OF GER RGD RIGID A.F.F. OR AFF ABOVE FINISH FLOOR RECORD REGISTERED PROFESSIONAL RPT GN GENERAL NOTE(S) TECHNICIAN AHJ AUTHORITY HAVING JURISDICTION RTU ROOF TOP UNIT GR GRADE AISC AMERICAN INSTITUTE OF STEEL S/ SIDE OF CONSTRUCTION GYP OR GWB GYPSUM WALL BOARD ALT ALTERNATE H OR HT HEIGHT SCHED SCHEDULE ALUM ALUMINUM HDG HOT -DIPPED GALVANIZED SOS SELF DRILLING SCREWS AOR ARCHITECT OF RECORD HDR HEADER SECT SECTION APPROX APPROXIMATE SF SQUARE FOOT HGR HANGER ARCH ARCHITECT OR ARCHITECTURAL SHT SHEET HI HIGH AMERICAN WOOD PROTECTION AWPA ACCOCIA71ON HI & LO HIGH AND LOW SHTG SHEATHING AWS AMERICAN WELDING SOCIETY HOR HORIZONTAL SIM SIMILAR B.F. OR BF BOTTOM FLUSH HS OR H.S. HEADED STUD SLBB SHORT LEG BACK TO BACK BLDG BUILDING HSS HOLLOW STRUCTURAL SECTION S.O.G. OR SOG SLAB ON GRADE BLDR BUILDER HVAC HEATING, VENTILATION, AND AIR SP SPACE OR SPACING BLKG BLOCKING CONDITIONING SPEC SPECIFICATION ICF INSULATED CONCRETE FORMS BM BEAM ID OR I.D. INSIDE DIAMETER S.S. OR SS STAINLESS STEEL BOT BOTTOMIF SSMA STEEL STUD MANUFACTURERASSOCIATION OR I.F. INSIDE FACE B.P. OR BP BASE PLATE IN INCH STD STANDARD BRG BEARING INFO [FORMATION STIFF STIFFENER BRK BRICK INT INTERIOR STIRR STIRRUPS BTWN BETWEEN INTERN INTERMEDIATE STL STEEL BSMT BASEMENT INS ORINSUL INSULATION STR. OR STRUC. STRUCTURAL B/ BOTTOM OF IT JOINT SUB SUBCONTRACTOR BOT BOTTOM SQ SQUARE JST JOIST CANT CANTILEVER K KIPS (1000 LBS. OR 1000#) S.W. OR SW SHEAR WALL CFM COLD FORMED METAL KLF KIP PER LINEAR FOOT SYM SYMMETRICAL C.J. OR Cl CONTROL JOINT CJP COMPLETE JOINT PENETRATION K/O KNOCK OUT T/ TOP OF C.L. OR CL CENTERLINE K5F KIP PER SQUARE FOOT T&B TOP AND BOT CLG CEILING L LENGTH T&G TONGUE AND GROOVE CLR CLEAR LBS POUNDS TEMP TEMPERATURE CMU CONCRETE MASONRY UNIT LOC LOCATION T.F. OR TF TOP FLUSH COL COLUMN LONG LONG OR LONGITUDINAL THK THICK OR THICKNESS COMP COMPRESSION OR COMPRESSIBLE LLBB LONG LEG BACK TO BACK TH RD THREADED ROD CONC CONCRETE LLH LONG LEG HORIZONTAL T.J. OR TJ TRIPLE JOIST CONNX CONNECTION LLV LONG LEG VERTICAL TOC OR T.O.C. TOP OF CONCRETE CONSTR CONSTRUCTION LB OR # POUND TOS OR T.O.S. TOP OF STEEL CONT CONTINUOUS LO LOW TOW OR T.O.W. TOP OF WALL CONTR CONTRACTOR LT LIGHT TPI TRUSS PLATE INSTITUTE COORD COORDINATE CONCRETE REINFORCING STEEL LW OR LT WT LIGHTWEIGHT TR OR TRANS TRANSVERSE CRSI INSTITUTE LWC LIGHTWEIGHT CONCRETE TYP TYPICAL CTR CENTER MAS MASONRY LILT ULTIMATE DB DROPPED BEAM MAIL MATERIAL U.N.O OR LINO UNLESS NOTED OTHERWISE DBL DOUBLE MAX MAXIMUM U.P.A. OR UPA UNDER POST ABOVE DEG OR ° DEGREE MC MOMENT CONNECTION U.W.A. OR UWA UNDER WALL ABOVE DET DETAIL MECH MECHANICAL V.C.B. OR VCB VERTICAL CRUSH BLOCKING DIA OR to 0 DIAMETER MECHANICAL, ELECTRICAL, VERT VERTICAL DIAG DIAGONAL MEP PLUMBING SPECIALTY SUB DIM DIMENSION MEZZ MEZZANINE V.I.F. OR VIF VERIFY IN FIELD D.J. OR DJ DOUBLE JOIST MID MIDDLE VNR VENEER DN DOWN MIN MINIMUM W/ WITH D.S. OR DS DOWN SPOUT MISC MISCELLANEOUS W/O WITHOUT DTL DETAIL MNFR OR MFR MANUFACTURER WD WOOD DWG DRAWING MTL METAL WF WIDE FLANGE BEAM DWL DOWEL NA OR N/A NOT APPLICABLE W.P. OR WP WORK POINT EA EACH N.B. OR NB NON -BEARING VJRB WEATHER -RESISTIVE BARRIER E.F. OR EF EACH FACE NIC OR N.I.C. NOT IN CONTRACT WS WATER STOP EIFS EXTERIOR INSULATION AND FINISH NISI NATIONAL INSTITUTE OF W.S.P. OR WSP WOOD STRUCTURAL PANEL SYSTEM STANDARDS AND TECHNOLOGY E.J ORE] EXPANSION JOINT NHR OR N.H.R. NO HEADER REQUIRED WT WEIGHT ELEC ELECTRICAL NO. OR # NUMBER W.W.F. OR WNIF WELDED WIRE FABRIC EL ELEVATION NOM NOMINAL XPS EXTRUDED POLYSTERENE ELEV ELEVATOR NS NEAR SIDE EMBED EMBEDDED OR EMBEDMENT NS & FS NEAR SIDE AND FAR SIDE E.N. OR EN OR P.E.N PANEL EDGE NAILING N.T.S. OR NTS NOT TO SCALE LOAD TYPE ABBREVIATIONS: ENG ENGINEER NWC NORMAL WEIGHT CONCRETE ASO ALLOWABLE STRESS DESIGN E.O.R. OR FOR ENGINEER OF RECORD LOAD AND RESISTANCE FACTOR O.C. OR OC ON -CENTER LRFD DESIGN E.P. OR EP EMBED PLATE DL DEAD LOAD OD OUTSIDE DIAMETER EPS EXPANDED POLYSTERENE ET CETERA (AND OTHER SIMILAR OF OUTSIDE FACE LL LIVE LOAD ETC THINGS) OPNG OPENING RL ROOF LOAD EQ EQUAL OPP OPPOSITE SL SNOW LOAD EQUIP EQUIPMENT EL SEISMIC LOAD PARAL PARALLEL E.S. OR ES EACH SIDE SDL SUPERIMPOSED DEAD LOAD PERP PERPENDICULAR E,1V. OR EW EACH 'NAY PCF POUNDS PER CUBIC FOOT TL TOTAL LOAD EXIST OR (E) EXISTING EXP EXPANSION PIP PARTIAL JOINT PENETRATION WL WIND LOAD EXT EXTERIOR PL PLATE FAB FABRICATOR OR FABRICATE PLBG PLUMBING WOOD SPECIES ABBREVIATIONS: F/ FACE OF PLF POUNDS PER LINEAR FOOT AYC ALASKAN YELLOW CEDAR F.B. OR FB FLUSH BEAM PLWD PLYWOOD DF DOUGLAS FIR (SOUTH) FD FLOOR DRAIN POLYISO POLY ISOCYAN U RATE INSULATION DFL DOUGLAS FIR LARCH F.F.E. OR FFE FINISHED FLOOR ELEVATION PREFAB PREFABRICATED ERC EASTERN RED CEDAR FIN FINISH PRO] PROJECT OR PROJECTION HF HEM FIR FL OR FLR FLOOR PSF POUNDS PER SQUARE FOOT SPF SPRUCE PINE FIR FL.FR. OR FLFR FLOOR FRAMING PSI POUNDS PER SQUARE INCH SYP SOUTHERN YELLOW PINE FLUHG FLASHING PRESSURE TREATED (LUMBER) PT POST TENSIONED (CONCRETE) WRC WESTERN RED CEDAR FND OR FDN FOUNDATION PVMT PAVEMENT F.O.C. FACE OF CONCRETE QTY QUANTITY ENGINEERED LUMBER TYPES: F.0.5 FACE OF STEEL R RADIUS GLB OR GLULAM GLUE -LAMINATED TIMBER FP FIREPLACE R.O. OR RO ROUGH OPENING LVL LAMINATED VENEER LUMBER FR OR FRMG FRAMING RAF RAFTER LSL LAMINATED STRAND LUMBER RESEARCH COUNCIL ON RCSC PSL PARALLEL STRAND LUMBER FRM FRAME STRUCTURAL CONNECTIONS S26129 I2:191b] 4146 0 49hrolA z r_r 1111 col► PROJECT ADDRESS 101 CROSS CREEK DR GRAPEVINE, TX ARCHITECT EXURB STUDIO, LLC 1038 MEADOW BEND LOOP N 214-679-3580 INFO@EXURBSTUDIO.COM STRUCTURAL ENGINEER L120 ENGINEERING & DESIGN P.O. BOX 1447 GRAPEVINE, TX 76099 PHONE: (214) 625-2819 CONTACT: ALIAKSEI PATSEVICH, PE DESIGN CRITERIA APPLICABLE INTERNATIONAL BUILDING AND/OR RESIDENTIAL CODE EDITION: 2021 AND AMENDMENTS AS ADOPTED BY THE REVIEWING AGENCY/COUNTY. RISK CATEGORY ..................II BASIC WIND SPEED ..................115 MPH WIND EXPOSURE ... B TOPOGRAPHIC FACTOR KA-1.0 SEISMIC DESIGN CATEGORY ...... B SITE CLASS .... D SS ... 0.12 51...0.059 DEAD LOADS AS SPECIFIED IN THE "DESIGN WEIGHTS OF ASSEMBLIES" NOTE 116 OF THE GENERAL STRUCTURAL NOTES. LIVE LOADS AND AS SPECIFIED IN THE "LIVE LOADS" NOTE 117 OF THE GENERAL STRUCTURAL NOTES DEFLECTION CRITERIA AS SPECIFIED IN THE "DEFLECTION LIMITS" NOTE 118 OF GENERAL STRUCTURAL NOTES. GROUND SNOW LOAD .... 12 PSF GEOTECHNICAL REPORT PTI DESIGN PARAMETERS: DIFFERENTIAL SWELL FOR EDGE LIFT, = DIFFERENTIAL SWELL FOR CENETER LIFT, = EDGE MOISTURE VARIATION, EDGE LIFT, = EDGE MOISTURE VARIATION, CENTER LIFT, = LATERAL EARTH PRESSURE DESIGN PARAMETERS: ACTIVE .... 35 PSF/FT AT REST ... 55 PSF/FT PASSIVE.... 250 PSF/FT COEFFICIENT OF BASE FRICTION: 0.30 q 130521 �P�,� �'•���ENSE�••'•� �� ONAL ENG w co z (7 Dz0 W 03 r� Z V � W Z wg Za 00W J M O1 57 C] U% 1p U ,--I 4zk x Cj� LLI w � z z_ J w U Lu a z W X � O U .-1 _J X O Lu m cn L Q 00 fV Lr) fV tD REVISIONS 0 DATE BY PIER DESIGN VALUES: PROJECT NAME END BEARING.... SKIN FRICTION.... 101 CROSS CREEK UPLIFT SKIN FRICTION.... OVER TOP XX FEET GARAGE ADDITION SHEET INDEX S-100 COVER SHEET S-101 GENERAL STRUCTURAL NOTES PROJECT ADDRESS S-301 FRAMING NOTES AND DETAILS 101 CROSS CREEK DR S-302 FRAMING NOTES AND DETAILS S-311 FIRST LEVEL CEILING FRAMING PLAN GRAPEVINE, TX S-312 ROOF FRAMING PLAN S-401 WALL BRACING NOTES DETAILS AND SCHEDULES PROJECT NUMBER S-411 FIRST FLOOR SHEAR WALL PLAN S-412 SECOND FLOOR SHEAR WALL PLAN S26129 CHECKED BY - AP G N 001. LEGEND SHEET DATE - 05/04/2026 1 3/4" X 14" LVL DTL. SECTION CALLOUT PER PLAN SCALE I - WOOD BEAM (EXAMPLE) 5HT. - HANGER AS REQ'D DTL, 24X36 SHEET:1/2"=1'-0" C— - — - WOOD JOIST Ste' - HANGER AS REQ'D I I - PLAN DETAIL CALLOUT PER PLAN Lv W10X15 - STEEL BEAM (EXAMPLE) - - MOMENT CONNECTION z - TRUSS OR JOIST F_ SPREAD FOOTING (n o (LENGTH X WIDTH X DEPTH) EXTENT OF SIMILAR �_o F SPACED JOIST OR �F� Z o TRUSSES -jo HOLDOWN OR VERTICAL STRAP LJ - HANGER AS REQ'D A OI GT -GIRDER TRUSS J - STEP AT TOP tea./ ROOF BRACE STEP AT BOT - HIGH END SHEAR WALL CALLOUT. - LOW END SW6 t/ REFER TO SHEARWALL SCHEDULE CS16 - - - - - - INDICATES SHEARWALL - HORIZONTAL STRAP LOCATION AND EXTENTS - BLOCKED DIAPHRAGM 99'-6" - SPOT ELEVATION PIER CALLOUT ® -WOOD STUD OR POST XX / X / X Lu W O 1 JACK - INDICATES THE NUMBER OF KING AND KT/PIER EL 0 /_2 KING JACK STUDS AT SIDE OF OPENING PENETRATION INTO a IU) UO GRAY LIMESTONE (FT) cl� cl� 1011— V.C.B. - VERTICAL CRUSH BLOCKING ALIGNED DIA (IN) U Lu UNDER POINT LOAD ABOVE TO MATCH Lu QUANTITY AND SIZE OF SUPPORT ABOVE 0 Lu U = GN100. GENERAL STRUCTURAL NOTES 100. GENERAL CONDITIONS 100.1. THESE STRUCTURAL PLANS ARE BASED ON INFORMATION PROVIDED TO THE ENGINEER OF RECORD (EOR). THE FOR SHALL BE ENTITLED TO RELY ON THE ACCURACY AND COMPLETENESS OF THIS INFORMATION IN THE PREPARATION OF THE CONSTRUCTION DOCUMENTS. 100.2. THE CONTRACTOR SHALL REVIEW THE STRUCTURAL DRAWINGS IN THEIR ENTIRETY PRIOR TO PROCEEDING WITH ANY WORK. ANY DISCREPANCIES CONFLICTS OR OMISSIONS IDENTIFIED BETWEEN STRUCTURAL DRAWINGS AND ANY OTHER PROJECT DOCUMENTS SHALL BE REPORTED IN WRITING TO THE ARCHITECT THE FOR AND ALL OTHER APPLICABLE PARTIES BEFORE CONSTRUCTION OF THE AFFECTED WORK BEGINS. THIS NOTIFICATION APPLIES THROUGHOUT ALL PHASES OF CONSTRUCTION AND IS REFERENCED THROUGHOUT THESE NOTES. 100.3. ALL CONSTRUCTION SHALL BE DONE WITH MATERIALS, METHODS, AND WORKMANSHIP ACCEPTED AS GOOD PRACTICE BY THE CONSTRUCTION INDUSTRY IN CONFORMANCE TO THE PROVISIONS OF THE INTERNATIONAL BUILDING CODE, AND STANDARDS REFERENCED THEREIN, AND ALL OTHER REGULATING AGENCIES EXERCISING AUTHORITY OVER ANY PORTION OF THE WORK. 100.4. IN CASE OF CONFLICT, SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE THE NOTES, DRAWINGS, AND/OR SPECIFICATIONS DIFFER, THE MORE STRINGENT REQUIREMENT SHALL APPLY. IF A SPECIFIC DETAIL IS NOT SHOWN FOR ANY PART OF THE WORK, THE CONSTRUCTION SHALL BE THE SAME AS FOR SIMILAR WORK. 100.5. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT AND THE FOR OF ANY CONDITION THAT MAY ENDANGER OR CAUSE DISTRESS TO THE STRUCTURE. SEE NOTE 100.2 FOR GENERAL NOTIFICATION REQUIREMENTS. 100.6. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THEIR WORK AND SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS METHODS UES TECHNIQ SEQUENCES AND PROCEDURES. 100.7. THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION. THIS INCLUDES ALL MEASURES NECESSARY TO SAFELY SUPPORT STRUCTURAL COMPONENTS UNTIL THE PERMANENT STRUCTURAL SYSTEM IS FULLY IN PLACE AND SELF-SUPPORTING. 100.7.1. WHERE APPLICABLE, THE CONTRACTOR SHALL ENGAGE A QUALIFIED ENGINEER TO DESIGN AND CERTIFY TEMPORARY SHORING SYSTEMS, PARTICULARLY WHEN REMOVING OR MODIFYING EXISTING STRUCTURAL ELEMENTS OR WHERE SIGNIFICANT CONSTRUCTION SEQUENCING IS INVOLVED. 100.8. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR JOBSITE SAFETY. THE ENGINEER HAS NOT BEEN RETAINED TO PROVIDE SERVICES RELATED TO CONSTRUCTION SAFETY MEASURES, MEANS, METHODS, OR PROCEDURES. SITE VISITS BY THE ENGINEER SHALL NOT BE CONSTRUED AS SUPERVISION OF CONSTRUCTION ACTIVITIES OR IMPLY RESPONSIBILITY FOR JOBSITE SAFETY OR WORKING CONDITIONS. 100.9. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND THE FOR IN WRITING OF ALL PROPOSED FIELD CHANGES PRIOR TO INSTALLATION. 100.10. THESE GENERAL STRUCTURAL NOTES SHALL APPLY ONLY TO THE WORK PERFORMED BY THE FOR WITHIN THE DEFINED SCOPE OF THE EOR'S SERVICES. IF ANY GENERAL NOTE REFERENCES WORK THAT IS COVERED IN WHOLE OR IN PART BY ANOTHER TRADE, THE SPECIFICATIONS AND REQUIREMENTS OF THAT TRADE SHALL GOVERN FOR THE APPLICABLE SCOPE OF WORK. 100.11. THE CONTRACTOR SHALL MAINTAIN A COMPLETE RECORD OF ALL CONSTRUCTION -RELATED DOCUMENTATION, INCLUDING BUT NOT LIMITED TO MATERIAL TESTING RESULTS, PLACEMENT LOGS, INSPECTION REPORTS, AND SUBMITTALS, FOR THE DURATION OF THE APPLICABLE WARRANTY PERIOD. ALL SUCH RECORDS SHALL BE MADE AVAILABLE TO THE FOR UPON REQUEST. 100.12. 1T IS THE CONTRACTOR'S RESPONSIBILITY TO IDENTIFY ANY SPECIAL DOCUMENTATION REQUIRED BY A LOCAL JURISDICTION OR A THIRD PARTY. THIS INCLUDES ANY PROGRAM ENROLLMENT, INCLUDING BUT NOT LIMITED TO, A HOMEBUYER WARRANTY PROGRAM AND THE TEXAS DEPARTMENT OF INSURANCE (TDI). IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE ENGINEER OF THESE SPECIAL REQUIREMENTS IN A TIMELY MANNER. 101. MATERIAL STORAGE 101.1. ALL STRUCTURAL MATERIALS SHALL BE STORED IN A MANNER THAT PROTECTS THEM FROM MOISTURE, DIRECT SUNLIGHT, MECHANICAL DAMAGE, AND OTHER CONDITIONS THAT MAY ADVERSELY AFFECT THEIR STRUCTURAL PROPERTIES OR FITNESS FOR USE. UNLESS OTHERWISE SPECIFIED IN THE MATERIAL -SPECIFIC SECTIONS OF THESE NOTES, ALL MATERIALS SHALL BE: 101.1.1. STORED OFF THE GROUND ON LEVEL SUPPORTS OR BLOCKING TO PREVENT DIRECT CONTACT WITH SOIL OR STANDING WATER. 101.1.2. COVERED OR PROTECTED FROM DIRECT MOISTURE AND PRECIPITATION DURING STORAGE AND CONSTRUCTION. 101.1.3. SUPPORTED TO PREVENT WARPING, BOWING, OR PERMANENT DEFORMATION DURING STORAGE. 101.1.4. INSPECTED PRIOR TO INSTALLATION. MATERIALS THAT HAVE BEEN DAMAGED, EXCESSIVELY WETTED, WARPED, OR OTHERWISE COMPROMISED DURING STORAGE SHALL NOT BE INSTALLED AND SHALL BE REMOVED FROM THE JOBSITE. 101.1.5. STORED AND HANDLED IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED REQUIREMENTS WHERE APPLICABLE. 102. STRUCTURAL STEEL 102.1. ALL STRUCTURAL STEEL SHALL CONFORM TO THE LATEST EDITION OF AISC SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS AND APPLICABLE LOCAL BUILDING CODES. ALL MEMBERS SHALL BE STRAIGHT, TRUE TO LINE, AND FREE FROM DEFECTS. 102.2. STRUCTURAL STEEL SHAPES SHALL CONFORM TO THE FOLLOWING STANDARDS UNLESS OTHERWISE NOTED: 102.2.1. WIDE FLANGE (W-SHAPES): ASTM A992, FY = 50 KSI 102.2.2. CHANNELS, ANGLES, PLATES: ASTM A36, FY = 36 KSI 102.2.3. HOLLOW STRUCTURAL SECTIONS (HSS): ASTM A500 GRADE B, FY = 46 KSI 102.2.4. BOLTS: ASTM F3125 GRADE A325 OR A490, AS SPECIFIED 102.2.5. WELDS: PER AWS D1.1 USING E70XX ELECTRODES 102.3. ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS IN ACCORDANCE WITH AWS D1.1. WELDS SHALL BE CONTINUOUS UNLESS OTHERWISE INDICATED. WELDS NOT SPECIFICALLY DETAILED SHALL BE A MINIMUM 1/4" CONTINUOUS FILLET WELD. USE DRY E70 ELECTRODES FOR ALL FIELD WELDING. 102.4. ALL BOLTED CONNECTIONS SHALL BE MADE WITH HIGH -STRENGTH BOLTS UNLESS NOTED OTHERWISE. BOLTS SHALL BE TENSIONED USING TURN -OF -NUT OR CALIBRATED WRENCH METHODS PER RCSC GUIDELINES. 102.5. ALL STRUCTURAL STEEL SHALL BE SHOP -PRIMED WITH A RUST -INHIBITIVE PRIMER UNLESS NOTED AS GALVANIZED OR OTHERWISE PROTECTED. SURFACES TO BE FIELD -WELDED SHALL BE FREE OF PRIMER IN THE WELD ZONE. 102.6. FIELD MODIFICATIONS, INCLUDING BUT NOT LIMITED TO CUTTING, NOTCHING, DRILLING, OR PENETRATING OF STRUCTURAL STEEL MEMBERS, ARE NOT PERMITTED UNLESS EXPLICITLY SHOWN ON THE APPROVED DRAWINGS OR AUTHORIZED BY PRIOR WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER OF RECORD. 102.7. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO FABRICATION. DISCREPANCIES SHALL BE REPORTED PER NOTE 100.2. 102.8. THE CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AND BRACING AS REQUIRED TO ENSURE STABILITY OF THE STEEL FRAME DURING ERECTION. DO NOT REMOVE TEMPORARY SUPPORTS UNTIL THE STRUCTURE IS FULLY STABLE. 102.9. THE CONTRACTOR SHALL COORDINATE PLACEMENT OF ALL EMBEDDED STEEL PLATES, ANCHOR BOLTS, AND SLEEVES WITH CONCRETE WORK TO ENSURE ACCURATE PLACEMENT. 102.10. GROUT BENEATH BASE PLATES SHALL BE NON -SHRINK AND INSTALLED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. 102.11. FIREPROOFING AND COATING SYSTEMS ARE NOT INCLUDED IN THE STRUCTURAL SCOPE AND SHALL BE PROVIDED AS REQUIRED BY OTHERS. MINIMUM CORROSION RESISTANCE FOR STRUCTURAL STEEL EXPOSED TO WEATHER SHALL BE AS FOLLOWS: 102.11.1. ALL STRUCTURAL STEEL FRAMING EXPOSED TO WEATHER SHALL BE PROTECTED WITH A CORROSION -RESISTANT COATING SYSTEM. UNO, EXPOSED STEEL SHALL BE HOT -DIPPED GALVANIZED OR PAINTED WITH AN APPROVED PRIMER AND FINISH COATING SUITABLE FOR EXTERIOR EXPOSURE. SURFACES SHALL BE PREPARED AND COATINGS SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS AND RECOMMENDATIONS. 103. DIMENSIONAL LUMBER 103.1. ALL SOFTWOOD LUMBER SHALL COMPLY WITH THE LATEST EDITION OF THE AMERICAN SOFTWOOD LUMBER STANDARD DOC PS 20, AS PUBLISHED BY THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY (NIST). 103.2. SAWN LUMBER SHALL BE IDENTIFIED BY A GRADE MARK BY AN ACCREDITED AGENCY PER DOC PS 20; APPROVED END -JOINTED LUMBER OF THE SAME SPECIES AND GRADE MAY BE USED INTERCHANGEABLY WITH SOLID -SAWN MEMBERS AND SHALL BE DESIGNATED "HRA" WHERE FIRE -RESISTANCE IS REQUIRED. 103.3. LUMBER SHALL BE SURFACED DRY (S-DRY) OR KILN -DRIED (KD) WITH A MAXIMUM MOISTURE CONTENT OF 19% AT TIME OF INSTALLATION. 103.4. LUMBER GRADE SHALL BE AS SPECIFIED IN THE GENERAL FRAMING NOTES. 103.5. LUMBER USED IN EXTERIOR OR HIGH -MOISTURE CONDITIONS, AND ANY WOOD LOCATED WITHIN 6 INCHES OF FINISHED GRADE, SHALL BE PRESERVATIVE -TREATED AND LABELED ACCORDINGLY, IN ACCORDANCE WITH AWPA U1 AND AWPA M4 STANDARDS. 103.6. ALL LUMBER SHALL BE STORED PER NOTE 101.1. 104. ENGINEERED LUMBER 104.1. ALL ENGINEERED WOOD PRODUCTS SHALL BE MANUFACTURED IN ACCORDANCE WITH APPLICABLE STANDARDS, INCLUDING: 104.1.1. ASTM D5456 FOR PSL AND LSL 104.1.2. APA EWS FOR LVL 104.1.3. APA PRR 410 FOR RIM BOARD 104.1.4. ASTM D5055 FOR PREFABRICATED WOOD I -JOISTS 104.2. PRODUCTS SHALL BEAR A LEGIBLE STAMP OR LABEL IDENTIFYING THE MANUFACTURER, GRADE OR SERIES, EVALUATION REPORT NUMBER, AND CERTIFICATION AGENCY MARK. 104.3. MEMBERS SHALL BE SIZED AND INSTALLED PER STRUCTURAL DRAWINGS AND MANUFACTURER'S PUBLISHED LITERATURE. 104.4. FIELD MODIFICATIONS, INCLUDING BUT NOT LIMITED TO CUTTING, NOTCHING, DRILLING, OR PENETRATING OF ENGINEERED WOOD MEMBERS, ARE NOT PERMITTED UNLESS EXPLICITLY SHOWN ON THE APPROVED DRAWINGS OR AUTHORIZED BY PRIOR WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER OF RECORD. 104.4.1. FOR PREFABRICATED I -JOISTS, WEB HOLES AND OPENINGS ARE PERMITTED ONLY WHERE SIZED, LOCATED, AND REINFORCED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 104.5. RIM BOARD SHALL CONFORM TO APA PRR 410 AND BE CLEARLY LABELED. ACCEPTABLE MATERIALS INCLUDE LVL, OR LSL AS PERMITTED UNDER PRR 410. RIM BOARD SHALL BE INSTALLED TIGHT TO ADJACENT FRAMING AND FASTENED PER PRR 410. DO NOT NOTCH OR DRILL UNLESS SPECIFICALLY ALLOWED BY THE MANUFACTURER OR DESIGN DOCUMENTS. 104.6. PREFABRICATED I -JOISTS SHALL CONFORM TO ASTM D5055 AND BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S SPAN TABLES AND INSTALLATION INSTRUCTIONS. 104.7. I -JOISTS SHALL BEAR FULLY ON APPROVED SUPPORTS AND BE LATERALLY BRACED AS REQUIRED. 104.7.1. JOIST HANGERS AND BLOCKING PANELS SHALL BE COMPATIBLE WITH I -JOIST SPECIFICATIONS AND FASTENED PER MANUFACTURER REQUIREMENTS. 104.8. ENGINEERED WOOD PRODUCTS SHALL BE STORED AND PROTECTED IN ACCORDANCE WITH NOTE 101.1. ENGINEERED WOOD PRODUCTS ARE PARTICULARLY SENSITIVE TO MOISTURE EXPOSURE AND SHALL NOT BE INSTALLED IF SWELLING, DELAMINATI N R THERM I T RE -RELATED DAMAGE I OBSERVED. S S G 0 0 0 OS U G SO S 104.9. THE CONTRACTOR SHALL VERIFY SPANS, LOADS, BEARING, AND FIT -UP PRIOR TO INSTALLATION. DISCREPANCIES SHALL BE COORDINATED WITH THE FOR PER NOTE 100.2. 105. GLUE -LAMINATED TIMBER (GLULAM) 105.1. GLULAM MEMBERS SHALL BE MANUFACTURED AND IDENTIFIED AS REQUIRED IN ANSI A190.1, ANSI 117, AND ASTM D3737. MEMBERS SHALL BEAR THE MANUFACTURER'S STAMP SHOWING GRADE, SPECIES, AND CERTIFICATION AGENCY. 105.2. MOISTURE CONTENT SHALL BE AS FOLLOWS: 105.2.1. KILN -DRIED GLULAM (TYPICALLY 12% f3% MOISTURE CONTENT) SHALL BE USED FOR INTERIOR OR PROTECTED EXTERIOR ENVIRONMENTS WHERE EXPOSURE TO MOISTURE IS MINIMAL. 105.2.2. WOLMANIZED OR TREATED GLULAM SHALL BE USED FOR EXTERIOR, EXPOSED, OR HIGH -MOISTURE ENVIRONMENTS. THESE MAY INCLUDE GLULAM FABRICATED FROM HIGHER -MOISTURE OR GREEN LUMBER AND/OR PRESSURE -PRESERVATIVE -TREATED PRODUCTS. THESE MEMBERS SHALL BE PROTECTED FROM PROLONGED WETTING AND INSTALLED WITH APPROPRIATE DETAILING (FLASHING, SEALING, ETC.). 105.3. GLULAM SHALL MATCH THE SIZES, SHAPES (STRAIGHT, CURVED, TAPERED), AND CAMBER AS SHOWN ON STRUCTURAL DRAWINGS. 105.4. GLULAM MEMBERS SHALL BE STORED AND PROTECTED IN ACCORDANCE WITH NOTE 101.1. GLULAM MEMBERS SHALL BE PROTECTED FROM DIRECT SUN AND WEATHER EXPOSURE TO PREVENT CHECKING, SURFACE WEATHERING, AND FINISH DEGRADATION. END GRAIN SHALL BE SEALED OR WRAPPED TO MINIMIZE DIFFERENTIAL MOISTURE ABSORPTION. 105.5. FIELD MODIFICATIONS, INCLUDING BUT NOT LIMITED TO CUTTING, NOTCHING, DRILLING, OR PENETRATING OF GLULAM MEMBERS, ARE NOT PERMITTED UNLESS EXPLICITLY SHOWN ON THE APPROVED DRAWINGS OR AUTHORIZED BY PRIOR WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER OF RECORD. 105.6. ALL FIELD CUTS, NOTCHES, AND FASTENER PENETRATIONS IN TREATED OR EXTERIOR -USE GLULAM SHALL BE SEALED WITH AN APPROVED PRESERVATIVE TREATMENT. 105.7. TYPICAL GLULAM GRADES SHALL BE AS FOLLOWS: 105.7.1. 24F-V4 DF FOR SINGLE SPANS 105.7.2. 24F-V8 DF FOR CANTILEVER BEAM OR CONTINUOUS MULTI -SPAN BEAMS 106. PRE-ENGINEERED WOOD OPEN WEB TRUSSES 106.1. WOOD TRUSSES SHALL BE DESIGNED BY A LICENSED TRUSS MANUFACTURER IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICE AND ANSI/TPI 1 STANDARDS. 106.2. THE TRUSS DESIGN DRAWINGS SHALL BE PREPARED AND SEALED BY A REGISTERED DESIGN PROFESSIONAL. 106.3. THE TRUSS DESIGNER SHALL REVIEW THE ARCHITECTURAL AND STRUCTURAL DRAWINGS TO VERIFY PROPER APPLICATION OF ALL LOADS AS SPECIFIED IN SECTIONS 116 AND 117 OF THESE NOTES, TABULATED DEAD LOADS FROM SECTION 116 SHALL BE APPLIED AS UNIFORMLY DISTRIBUTED LOADS OVER THE TOP CHORD WITH AN ADDITIONAL 5 PSF DEAD LOAD APPLIED TO THE BOTTOM CHORD. 106.4. THE TRUSS DESIGNER SHALL ADHERE TO THE MAXIMUM DEFLECTION LIMITS SPECIFIED BY CODE AND PROJECT REQUIREMENTS AS SET FORTH IN THE SECTION 118 OF THESE NOTES, AS APPROPRIATE FOR THE APPLICATION OF THE TRUSSES. DEFLECTION CRITERIA SHALL ACCOUNT FOR THE INTENDED USE OF THE SPACE AND FINISHES ATTACHED TO THE TRUSS SYSTEM. 106.5. ALL TRUSS CONNECTIONS/HANGERS SHALL BE PER TRUSS DESIGN DRAWINGS. 106.6. TRUSSES SHALL NOT BE SPACED FURTHER APART THAN: 106.6.1. ROOF TRUSSES: 24" O.C. 106.6.2. FLOOR TRUSSES: 16" O.C. 106.7. TRUSS DESIGN DRAWINGS SHALL BE PROVIDED TO THE ENGINEER OF RECORD AND APPROVED PRIOR TO FABRICATION. TRUSS DESIGN DRAWINGS SHALL BE PROVIDED WITH THE SHIPMENT OF TRUSSES DELIVERED TO THE JOB SITE. TRUSS DESIGN DRAWINGS SHALL INCLUDE, AT A MINIMUM, THE FOLLOWING INFORMATION: 106.7.1. SLOPE, DEPTH, SPAN AND SPACING. 106.7.2. LOCATION OF ALL JOINTS. 106.7.3. REQUIRED BEARING WIDTHS. 106.7.4. DESIGN LOADS AS APPLICABLE. 106.7.4.1. TOP CHORD LIVE LOAD (AS DETERMINED FROM SECTION R301.6). 106.7.4.2. TOP CHORD DEAD LOAD. 106.7.4.3. BOTTOM CHORD LIVE LOAD. 106.7.4.4. BOTTOM CHORD DEAD LOAD. 106.7.4.5. CONCENTRATED LOADS AND THEIR POINTS OF APPLICATION. 106.7.4.6. CONTROLLING WIND AND EARTHQUAKE LOADS. 106.7.5. ADJUSTMENTS TO LUMBER AND JOINT CONNECTOR DESIGN VALUES FOR CONDITIONS OF USE. 106.7.6. EACH REACTION FORCE AND DIRECTION. 106.7.7. JOINT CONNECTOR TYPE AND DESCRIPTION SUCH AS SIZE, THICKNESS OR GAUGE AND THE DIMENSIONED LOCATION OF EACH JOINT CONNECTOR EXCEPT WHERE SYMMETRICALLY LOCATED RELATIVE TO THE JOINT INTERFACE. 106.7.8. LUMBER SIZE, SPECIES AND GRADE FOR EACH MEMBER. 106.7.9. CONNECTION REQUIREMENTS FOR: 106.7.9.1. TRUSS TO GIRDER TRUSS. 106.7.9.2. TRUSS TO BEAM. 106.7.9.3. TRUSS PLY TO PLY. 106.7.9.4. FIELD SPLICES, 106.7.10. CALCULATED DEFLECTION RATIO OR MAXIMUM DEFLECTION FOR LIVE AND TOTAL LOAD, OR APPLICABLE LOAD COMBINATION PRODUCING MAXIMUM DEFLECTION. 106.7.11. MAXIMUM AXIAL COMPRESSION FORCES IN THE TRUSS MEMBERS TO ENABLE THE BUILDING DESIGNER TO DESIGN THE SIZE, CONNECTIONS AND ANCHORAGE OF THE PERMANENT CONTINUOUS LATERAL BRACING. FORCES SHALL BE SHOWN ON THE TRUSS DESIGN DRAWING OR ON SUPPLEMENTAL DOCUMENTS. 106.7.12. REQUIRED PERMANENT TRUSS MEMBER BRACING LOCATION. 106.8. FOR VAULTED OR CATHEDRAL CEILING APPLICATIONS WITH SCISSOR TRUSSES: 106.8.1. TOP AND BOTTOM CHORD SLOPES MUST MATCH ARCHITECTURAL SECTION. 106.8.2. SCISSOR TRUSSES MUST BE DESIGNED FOR AN ENHANCED DEFLECTION ASSET FORTH IN THE SECTION 118 TO REDUCE THE POTENTIAL FOR CEILING CRACKS AND OUTWARD THRUST AT WALLS. 106.8.3. VERIFY HEEL HEIGHT TO ENSURE PROPER INSULATION AND VENTILATION CLEARANCE. 106.9. ROOF TRUSSES SUPPORTING MECHANICAL EQUIPMENT SHALL BE DESIGNED TO ACCOMMODATE ALL CONCENTRATED, DEAD, AND VIBRATION LOADS IMPOSED BY HVAC UNITS OR OTHER EQUIPMENT LOCATED WITHIN OR ABOVE THE TRUSS SYSTEM. IN THE AREA DESIGNATED AS THE MECHANICAL EQUIPMENT ZONE PER PLAN PER ARCHITECTURAL OR STRUCTURAL DRAWINGS, THE TRUSS DESIGNER SHALL ACCOUNT FOR AN ADDITIONAL LIVE LOAD EQUAL TO THE ATTIC LOAD WITH LIMITED STORAGE APPLIED ALONG THE BOTTOM CHORD OF THE AFFECTED TRUSSES. 106.9.1. FOR MECHANICAL HVAC EQUIPMENT THAT IS TO BE SUSPENDED FROM THE TOP CHORD OF THE TRUSS, THE TRUSS DESIGNER SHALL COORDINATE WITH THE BUILDER REGARDING THE WEIGHT OF THE EQUIPMENT AND THE EXACT LOCATION OF ALL SUPPORT POINTS, TO ENSURE PROPER DESIGN AND LOAD TRANSFER. REINFORCEMENT OR SUPPLEMENTAL MEMBERS SHALL BE PROVIDED AS REQUIRED 106.9.2. NO MECHANICAL EQUIPMENT SHALL BE PLACED ON OR WITHIN ATTIC TRUSSES WITHOUT PRIOR DESIGN APPROVAL. 107. WOOD SHRINKAGE 107.1. DUE TO CROSS -GRAIN SHRINKAGE IN WOOD FRAMING, THIS BUILDING IS EXPECTED TO EXPERIENCE VERTICAL SETTLEMENT OF APPROXIMATELY 3/8 INCH PER STORY. ALL PLUMBING, MECHANICAL, AND ELECTRICAL SYSTEMS SHALL BE DESIGNED WITH FLEXIBLE JOINTS, SLIP COUPLINGS, OR OTHER APPROPRIATE MEANS TO ACCOMMODATE THIS ANTICIPATED MOVEMENT. INTERIOR AND EXTERIOR SHEATHING, FINISHES, AND TRIM SHALL BE DETAILED AND INSTALLED TO PREVENT DAMAGE FROM DIFFERENTIAL SETTLEMENT. SHRINKAGE IS EXPECTED TO OCCUR PRIMARILY IN THE DEPTH OF FLOOR FRAMING AND PLATES, NOT IN THE LENGTH OF VERTICAL WALL STUDS. 108. WOOD STRUCTURAL PANELS 108.1. WOOD STRUCTURAL PANELS SHALL COMPLY WITH APPLICABLE APA PERFORMANCE STANDARDS: 108.1.1. PRP-108 FOR STRUCTURAL PLYWOOD, MANUFACTURED IN ACCORDANCE WITH U.S. DOC PS 1 108.1.2. PRP-210 FOR OSB AND OTHER NON -VENEER STRUCTURAL PANELS, MANUFACTURED IN ACCORDANCE WITH U.S. DOC PS 2 108.2. ALL PANELS SHALL BEAR A VALID APA GRADE STAMP (OR EQUIVALENT THIRD -PARTY CERTIFIED AGENCY) INDICATING PANEL TYPE, THICKNESS, SPAN RATING, EXPOSURE CLASSIFICATION, AND MILL IDENTIFICATION. 108.3. PANELS SHALL BE RATED EXPOSURE 1 (FOR PROTECTED CONSTRUCTION) OR EXTERIOR (FOR FULLY WEATHER -EXPOSED USE), AS APPROPRIATE TO PROJECT CONDITIONS. INTERIOR -ONLY PANELS ARE NOT PERMITTED IN STRUCTURAL APPLICATIONS. 108.3.1. WHERE MARINE GRADE PLYWOOD IS SPECIFIED, IT SHALL COMPLY WITH U.S. DOC PS 1 REQUIREMENTS FOR MARINE GRADE CLASSIFICATION, BEARING AN APA STAMP DESIGNATING "MARINE". 108.4. ALL PANELS SHALL BE INSTALLED WITH FACE GRAIN PERPENDICULAR TO SUPPORTS. 108.5. PANELS SHALL BE SPACED WITH 1/8" GAPS AT EDGES AND ENDS TO ALLOW FOR EXPANSION, UNLESS OTHERWISE NOTED. 108.6. FASTENING SHALL COMPLY WITH IBC TABLE 2304.10.1 OR IRC TABLE R602.3(1), GENERAL FRAMING NOTES, AND ANY APPLICABLE STRUCTURAL DETAILS OR SHEAR WALL SCHEDULES. NAILS SHALL BE DRIVEN FLUSH AND SHALL NOT FRACTURE THE SURFACE OF SHEATHING. 108.7. FASTENERS IN CONTACT WITH TREATED WOOD SHEATHING OR USED IN EXTERIOR APPLICATIONS SHALL BE HOT -DIP GALVANIZED ASTM A153 OR STAINLESS STEEL. 108.8. WHERE APPLICABLE, USE APA-APPROVED CONSTRUCTION ADHESIVES IN COMBINATION WITH MECHANICAL FASTENERS FOR FLOOR SHEATHING SYSTEMS. 108.9. FIELD MODIFICATIONS, INCLUDING BUT NOT LIMITED TO CUTTING, NOTCHING, DRILLING, OR PENETRATING OF WOOD STRUCTURAL PANELS, ARE NOT PERMITTED UNLESS EXPLICITLY SHOWN ON THE APPROVED DRAWINGS OR AUTHORIZED BY PRIOR WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER OF RECORD. 109. FIRE RETARDANT -TREATED (FRT) WOOD 109.1. WHERE FIRE -RETARDANT -TREATED (FRT) LUMBER OR PLYWOOD IS SPECIFIED OR REQUIRED BY CODE, IT SHALL BE PRESSURE -IMPREGNATED WITH FIRE -RETARDANT CHEMICALS IN ACCORDANCE WITH AWPA C20 (LUMBER) OR C27 (PLYWOOD). FRT WOOD SHALL BE CLEARLY LABELED AND SHALL NOT BE USED INTERCHANGEABLY WITH UNTREATED MEMBERS. ALL FASTENERS AND CONNECTORS IN CONTACT WITH FRT WOOD SHALL COMPLY WITH THE REQUIREMENTS OF NOTES 110.3 AND 111.3 RESPECTIVELY. 110. MECHANICAL FASTENERS T 110.1 FASTENERS SHALL CONFORM TO APPLICABLE STANDARDS. INSTALLATION SHALL FOLLOW NDS REQUIREMENTS AS WELL AS FASTENER AND CONNECTOR MANUFACTURER'S REQUIREMENTS. FASTENERS SHALL BE COMPATIBLE WITH ALL HARDWARE PER MANUFACTURER SPECIFICATIONS. 110.2. NAILING SHALL BE IN ACCORDANCE WITH IBC TABLE 2304.10.1, IRC TABLE R602.3(1), THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION (NDS), OR AS SPECIFIED IN THE TYPICAL NAILING SCHEDULE OF THE GENERAL FRAMING NOTES, UNO ON THE DRAWINGS OR SPECIFIC DETAILS. 110.3. STANDARD FASTENERS SHALL BE CARBON STEEL UNLESS OTHERWISE NOTED. FASTENER CORROSION PROTECTION SHALL COMPLY WITH THE FOLLOWING REQUIREMENTS: 110.3.1. ALL MECHANICAL FASTENERS (NAILS, BOLTS, LAG SCREWS, NUTS, AND WASHERS) IN CONTACT WITH PRESSURE -TREATED, FIRE -RETARDANT -TREATED (FRT), OR EXTERIOR -EXPOSED WOOD SHALL BE HOT -DIP GALVANIZED, STAINLESS STEEL, OR MANUFACTURER APPROVED EQUIVALENT COATED FASTENERS, IN ACCORDANCE WITH THE FOLLOWING APPLICABLE STANDARDS: 110.3.1.1. NAILS: ASTM A153 CLASS D 110.3.1.2. BOLTS, LAG SCREWS, NUTS, AND WASHERS: ASTM A153 CLASS C OR ASTM F2329. 110.3.1.3. STAINLESS STEEL: TYPE 304 OR 316. 110.3.1.3.1. USE TYPE 304 OR 316 STAINLESS STEEL OR HDG FASTENERS IN EXPOSED, COASTAL, HIGH -MOISTURE, OR CHEMICALLY TREATED ENVIRONMENTS. 110.3.1.3.2. TYPE 316 STAINLESS STEEL IS REQUIRED WITHIN 300 FEET OF A SALTWATER SHORELINE OR WHERE EXPOSURE TO SALT AIR OR SALTWATER IS ANTICIPATED. 110.3.2. ELECTROPLATED OR MECHANICALLY GALVANIZED FASTENERS ARE NOT PERMITTED FOR USE WITH PRESERVATIVE -TREATED OR FIRE -RETARDANT -TREATED (FRT) WOOD UNLESS SPECIFICALLY APPROVED IN WRITING BY THE EOR. 110.3.3. FASTENER FINISH AND CORROSION -RESISTANCE LEVEL SHALL BE COMPATIBLE WITH AND MATCHED TO THE CONNECTOR OR HARDWARE IT IS USED WITH. REFERENCE NOTE 111.3 FOR ADDITIONAL INFORMATION. 110.4. NAILS SHALL BE SMOOTH - COMMON, OR BOX NAILS AS SPECIFIED, AND MEET THE REQUIREMENTS OF ASTM F1667. PNEUMATICALLY DRIVEN NAILS MUST MATCH REQUIRED DIAMETER AND PENETRATION. NAILS USED FOR FRAMING AND SHEATHING CONNECTIONS SHALL HAVE A MINIMUM AVERAGE BENDING YIELD STRENGTH AS SHOWN: 110.4.1. 8OKSI FOR SHANK DIAMETER OF 0.192 INCH 110.4.2. 9OKSI FOR SHANK DIAMETER LARGER THAN 0.142 INCH BUT NOT LARGER 0.177 INCH 110.4.3. 100KSI FOR SHANK DIAMETERS OF 0.142 INCH OR LESS 110.5. SCREWS: MUST BE STRUCTURAL -RATED (E.G., RSS, SDS, SDWS, OR OTHERS AS SPECIFIED). SCREWS NOT SPECIFICALLY RATED FOR STRUCTURAL USE ARE NOT PERMITTED FOR STRUCTURAL APPLICATIONS. SCREWS SHALL NOTE BE USED IN LIEU OF NAILS UNLESS SPECIFICALLY CALLED OUT ON THE PLANS, NOTES, DETAILS, OR AS REQUIRED BY THE MECHANICAL CONNECTOR MANUFACTURER. 110.6. BOLTS: SHALL MEET ASTM F3125 GRADE A325 OR A490 AND INCLUDE WASHERS UNDER ALL NUTS AND HEADS BEARING AGAINST WOOD. 110.7. LAG SCREWS: SHALL BE PROPERLY PREDRILLED UNLESS SELF -DRILLING TYPES ARE USED AND SHALL MEET CORROSION REQUIREMENTS AS ABOVE. 110.8. AVOID COMBINATIONS OF DISSIMILAR METALS THAT MAY CAUSE GALVANIC CORROSION. INCLUDING ALUMINUM IN CONTACT WITH STEEL OR COPPER, OR MIXING OF STAINLESS STEEL AND GALVANIZED COMPONENTS, WHERE DISSIMILAR METALS CANNOT BE AVOIDED, AN APPROVED ISOLATION BARRIER OR COATING SHALL BE PROVIDED. SEE NOTES 110.3.3 AND 111.3.4 FOR SPECIFIC FASTENER AND CONNECTOR COMPATIBILITY REQUIREMENTS. 110.9. FASTENERS SHALL BE INSTALLED TO FULL REQUIRED DEPTH AND SEATED SNUGLY WITHOUT OVERDRIVING. 110.10. IMPROPERLY DRIVEN OR MISALIGNED FASTENERS SHALL BE REMOVED AND REPLACED. 110.11. MAINTAIN PROPER EDGE DISTANCES, END DISTANCES, AND SPACING AS SPECIFIED IN THE NDS AND PROJECT DRAWINGS. 110.12. SUBSTITUTIONS, ALTERATIONS IN FASTENER TYPE, OR SPACING SHALL NOT BE MADE WITHOUT WRITTEN APPROVAL FROM THE EOR. 111. MECHANICAL CONNECTORS 111.1. ALL CONNECTORS (E.G., JOIST HANGERS, STRAPS, POST BASES, HOLDOWNS, TIE PLATES, FRAMING ANGLES) SHALL BE MANUFACTURED IN ACCORDANCE WITH APPLICABLE STANDARDS INCLUDING ICC-ES AC13, AC233, OR OTHER RECOGNIZED ACCEPTANCE CRITERIA, AND INSTALLED PER BUILDING CODE AND MANUFACTURER'S PUBLISHED INSTALLATION REQUIREMENTS. 111.2. CONNECTORS SHALL BE PRODUCTS OF RECOGNIZED STRUCTURAL HARDWARE MANUFACTURERS SUCH AS SIMPSON STRONG -TIE, USP STRUCTURAL CONNECTORS, OR APPROVED EQUIVALENT. ALL SUBSTITUTIONS MUST BE PRE -APPROVED IN WRITING BY THE EOR. 111.3. CONNECTORS IN CONTACT WITH PRESSURE -TREATED, FIRE -RETARDANT -TREATED (FRT), OR EXTERIOR -EXPOSED WOOD SHALL BE: 111.3.1. HOT -DIP GALVANIZED PER ASTM A653 G185 OR ASTM A123 AS APPLICABLE 111.3.2. STAINLESS STEEL TYPE 304 OR 316, AS APPROPRIATE 111.3.3. ELECTRO-GALVANIZED (G60) OR PAINTED CONNECTORS ARE NOT ACCEPTABLE IN TREATED OR EXTERIOR APPLICATIONS 111.3.4. CONNECTORS AND THEIR ASSOCIATED FASTENERS SHALL BE OF COMPATIBLE AND MATCHING CORROSION -RESISTANCE LEVELS. STAINLESS STEEL CONNECTORS SHALL BE FASTENED WITH STAINLESS STEEL FASTENERS, AND HOT -DIP GALVANIZED CONNECTORS SHALL BE FASTENED WITH HOT -DIP GALVANIZED FASTENERS OF EQUIVALENT OR GREATER ZINC COATING WEIGHT. MIXING OF DISSIMILAR METAL FINISHES BETWEEN CONNECTORS AND FASTENERS IS NOT PERMITTED. 111.4. USE ONLY MANUFACTURER -SPECIFIED FASTENERS (TYPE, SIZE, NUMBER, AND SPACING) WITH EACH CONNECTOR. SIZE AND QUANTITY OF FASTENERS SHALL BE SELECTED TO ACHIEVE MAXIMUM SPECIFIED LOAD FOR THE CONNECTOR. 111.5. SUBSTITUTION OF NAILS WITH SCREWS, OR VICE VERSA, OR SUBSTITUTION OF NAILS FOR SMALLER SIZE OR DIAMETER IS NOT PERMITTED UNLESS APPROVED IN WRITING BY THE FOR OR NOTED IN THE APPROVED DRAWINGS. 111.6. ALL CONNECTORS SHALL BE INSTALLED FLUSH WITH THE WOOD SURFACE AND FULLY FASTENED USING THE SPECIFIED PATTERN AND NUMBER OF FASTENERS. OVERDRIVEN OR IMPROPERLY ALIGNED CONNECTORS MUST BE REMOVED AND REPLACED. 111.7. FIELD WELDING, CUTTING, OR BENDING OF CONNECTORS IS NOT PERMITTED UNLESS SPECIFICALLY DESIGNED FOR SUCH MODIFICATION. 111.8. WHERE CONNECTORS ATTACH TO CONCRETE OR MASONRY, USE ANCHORS (E.G., EXPANSION BOLTS, EPDXY -SET ANCHORS, OR CONCRETE BOLTS) AS SPECIFIED ON DRAWINGS AND RATED FOR THE INTENDED LOAD. 111.9. CONTRACTOR SHALL VERIFY THAT ALL INSTALLED CONNECTORS ARE OF THE CORRECT TYPE AND ORIENTATION, AND THAT ALL FASTENERS ARE IN PLACE PRIOR TO CONCEALMENT OR COVERING. 112. POST -INSTALLED ANCHORS 112.1. POST -INSTALLED MECHANICAL ANCHORS (EXPANSION, SCREW -TYPE, OR UNDERCUT) SHALL BE ICC-ES LISTED AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS AND THE APPLICABLE ICC-ES EVALUATION REPORT. ANCHORS SHALL NOT BE INSTALLED IN CRACKED CONCRETE UNLESS SPECIFICALLY RATED AND ICC-ES LISTED FOR SUCH USE. 112.2. ANCHOR TYPE, SIZE, EMBEDMENT DEPTH, AND EDGE AND SPACING DISTANCES SHALL BE AS SHOWN ON THE STRUCTURAL DRAWINGS AND SHALL COMPLY WITH ACI 318 AND THE MANUFACTURER'S PUBLISHED REQUIREMENTS. SUBSTITUTIONS SHALL NOT BE MADE WITHOUT WRITTEN APPROVAL FROM THE EOR. 113. EPDXY ADHESIVES 113.1. EPDXY ADHESIVES SHALL BE TWO -COMPONENT, HIGH -STRENGTH, STRUCTURAL EPDXY BONDING AGENTS SUITABLE FOR ANCHORING APPLICATIONS IN CRACKED AND UNCRACKED CONCRETE. 113.2. EPDXY ADHESIVE SHALL MEET OR EXCEED THE PERFORMANCE STANDARDS OF THE FOLLOWING PRODUCT: 113.2.1. SIMPSON STRONG -TIE® SET-3G'" - HIGH -STRENGTH, TWO -COMPONENT EPDXY ADHESIVE OR APPROVED EQUIVALENT. 113.2.2. MUST BE ICC-ES LISTED (E.G., ESR-4057 OR CURRENT ICC-ES LISTED EQUIVALENT), SUITABLE FOR SEISMIC, WIND, AND SUSTAINED LOADS. 113.3. MIN INSTALLATION REQUIREMENTS SHALL BE AS FOLLOWS: 113.3.1. PRIOR TO EPDXY PLACEMENT, HOLES SHALL BE DRILLED AND CLEANED PER MANUFACTURER'S INSTRUCTIONS. 113.3.2. EPDXY SHALL BE DISPENSED USING A STATIC MIXING NOZZLE PROVIDED BY THE MANUFACTURER. 113.3.3. ANCHOR ELEMENTS SHALL BE INSERTED WHILE ROTATING TO ENSURE COMPLETE WETTING AND TO AVOID VOIDS. 113.3.4. ANCHORS SHALL REMAIN UNDISTURBED UNTIL THE ADHESIVE HAS FULLY CURED. REFER TO MANUFACTURER'S CURE TIMES BASED ON AMBIENT AND SUBSTRATE TEMPERATURES. 113.4. QUALITY CONTROL 113.4.1. EPDXY INSTALLATION SHALL BE PERFORMED BY QUALIFIED PERSONNEL. 113.4.2. THE CONTRACTOR SHALL MAINTAIN RECORDS OF BATCH NUMBERS, INSTALLATION TEMPERATURES, AND CURE TIMES. 113.4.3. FIELD PULL TESTING MAY BE REQUIRED AT THE DISCRETION OF THE EOR. 113.4.4. EPDXY ADHESIVES SHALL BE STORED AND HANDLED IN ACCORDANCE WITH NOTE 101.1 AND THE MANUFACTURER'S PUBLISHED REQUIREMENTS. EPDXY SHALL BE STORED WITHIN THE TEMPERATURE RANGE SPECIFIED BY THE MANUFACTURER. EXPOSURE TO EXTREME HEAT, COLD, OR DIRECT SUNLIGHT SHALL BE AVOIDED. 113A.5. EPDXY ADHESIVES SHALL NOT BE USED BEYOND THE MANUFACTURER'S STATED SHELF LIFE OR EXPIRATION DATE. EXPIRED MATERIAL SHALL BE REMOVED FROM THE JOBSITE AND PROPERLY DISPOSED OF. 114. WALL COVERING 114.1. EXTERIOR WALL COVERING SHALL BE DESIGNED BY OTHERS TO PROVIDE A WEATHER -RESISTANT ENVELOPE INCLUDING FLASHING AS REQUIRED. THE WALL ASSEMBLY SHALL INCORPORATE A WATER -RESISTIVE BARRIER BEHIND THE EXTERIOR CLADDING AND A MEANS OF DRAINING WATER THAT PENETRATES THE CLADDING TO THE EXTERIOR. 114.2. WOOD SIDING, PANEL SIDING, SHAKES, AND SHINGLES SHALL BE INSTALLED PER APPLICABLE CODE AND MANUFACTURER REQUIREMENTS, WITH REQUIRED SHEATHING OR FURRING, PROPER NAILING, WATER -RESISTIVE BARRIER, AND ALL JOINTS LOCATED OVER FRAMING AND LAPPED OR FLASHED, 114.3. PLASTER OR STUCCO: COMPLY WITH ASTM C926, C1063, AND APPLICABLE CODES. USE APPROVED CEMENT TYPES. APPLY THREE -COAT OVER LATH, TWO -COAT OVER MASONRY/CONCRETE. STOP AT WEEP SCREED FOR SLAB -ON -GRADE WOOD CONSTRUCTION. 114.4. ANCHORED VENEER (STONE/ MASONRY): INSTALL PER APPLICABLE CODE AND MANUFACTURER REQUIREMENTS. MAX THICKNESS ALLOWED: 3 5/8", FOR THICKER VENEER CONTRACTOR SHALL NOTIFY THE FOR IN WRITING PRIOR TO CONSTRUCTION COMMENCEMENT FOR VERIFICATION OF SUPPORT REQUIREMENTS. PROVIDE MOVEMENT JOINTS AT TRANSITIONS BETWEEN MASONRY SUPPORTED BY THE FRAMING AND THE FOUNDATION. USE CORROSION -RESISTANT TIES SPACED MAX 16" O.C. EACH WAY AND WITHIN 12" OF LARGE OPENINGS. MORTAR: ASTM C270 TYPE N. 114.4.1. ADHERED MASONRY VENEER: COMPLY WITH APPLICABLE CODES AND TMS 402 602. MAINTAIN REQUIRED CLEARANCE ABOVE GRADE/PAVING. 115. ROOF COVERINGS 115.1. ALL ROOFING MATERIALS AND ASSEMBLIES SHALL COMPLY WITH THE APPLICABLE BUILDING CODE, MANUFACTURER'S INSTALLATION INSTRUCTIONS, APPLICABLE ASTM STANDARDS, AND APPROVED EVALUATION REPORTS (ICC-ES, UL, ETC). 115.2. ROOF COVERING TYPE (E.G., ASPHALT SHINGLES, METAL PANELS, TILE, TPO MEMBRANE) SHALL MATCH THE ARCHITECTURAL SPECIFICATIONS AND DETAILS, AND SHALL BE SUITABLE FOR THE INSTALLED SLOPE, AND MINIMUM SLOPE REQUIREMENTS SHALL BE MET PER CODE AND PRODUCT MANUFACTURER: 115.2.1. ASPHALT SHINGLES: MIN. 2:12 WITH DOUBLE UNDERLAYMENT; MIN. 4:12 WITH SINGLE UNDERLAYMENT 115.2.2. METAL PANELS: VARIES BY PROFILE AND SEAM TYPE 115.2.3. LOW -SLOPE SYSTEMS (E.G., TPO, EPDM): DESIGNED PER NRCA OR FM GUIDELINES 115.3. ALL MATERIALS SHALL BE CLASS A FIRE -RATED WHERE REQUIRED BY CODE OR PROJECT SPECIFICATIONS. 115.4. ROOF ASSEMBLIES SHALL PROVIDE POSITIVE DRAINAGE. FLAT ROOFS SHALL MAINTAIN A MINIMUM SLOPE OF 1/4" PER FOOT TOWARD DRAINS OR SCUPPERS UNLESS OTHERWISE DESIGNED AND DETAILED. 115.5. UNDERLAYMENT SHALL COMPLY WITH APPLICABLE STANDARDS (E.G., ASTM D226, D4869, D1970 FOR ICE BARRIER). 115.6. PROVIDE ICE AND WATER SHIELD, FLASHING AS REQ'D PER CODE AND MANUFACTURER GUIDELINES. 115.7. FASTENERS SHALL BE CORROSION -RESISTANT AND COMPATIBLE WITH THE ROOF COVERING AND DECK MATERIALS. FASTENING PATTERN AND TYPE SHALL FOLLOW MANUFACTURER WIND -RATED INSTALLATION INSTRUCTIONS OR CODE -REQUIRED UPLIFT RESISTANCE VALUES PER ASCE 7 AND LOCAL WIND ZONE REQUIREMENTS. 115.8. ALL ROOF PENETRATIONS (VENTS, FLUES, SKYLIGHTS, ETC.) SHALL BE PROPERLY FLASHED AND SEALED PER CODE AND MANUFACTURER DETAILS. STEP FLASHING, HEAD FLASHING, AND CONTINUOUS FLASHING AS SPECIFIED BY OTHERS SHALL BE INSTALLED AT ALL WALL -ROOF INTERSECTIONS. 115.9. ROOFING CONTRACTOR SHALL VERIFY SUBSTRATE CONDITION BEFORE INSTALLATION. DAMAGED OR IMPROPERLY INSTALLED COVERINGS SHALL BE REMOVED AND REPLACED. 115.10. SOLAR PANELS SHALL ONLY BE INSTALLED IN ROOF AREAS SPECIFICALLY DESIGNATED ON THE ROOF PLAN AS "SOLAR PANEL AREAS." INSTALLATION OF SOLAR PANELS OUTSIDE OF THESE DESIGNATED AREAS IS NOT PERMITTED WITHOUT PRIOR REVIEW AND WRITTEN APPROVAL BY THE ENGINEER OF RECORD (EOR). 116. DESIGN WEIGHTS OF ASSEMBLIES (DEAD LOADS) 116.1. THE CONTRACTOR SHALL REVIEW THE FOLLOWING DESIGN WEIGHTS OF ASSEMBLIES TABLE PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. IF ANY MATERIALS INTENDED FOR USE ON THE PROJECT EXCEED THE SPECIFIED MAXIMUM WEIGHT CRITERIA, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND THE FOR IN WRITING PRIOR TO CONSTRUCTION AND ALLOW ADEQUATE TIME FOR ANY NECESSARY DESIGN MODIFICATIONS: 116.2. EXT WALLS: 116.2.1. EXT WALL W/SIDING...12PSF 116.2.2. EXT WALL W/STUCC0... 15PSF 116.2.3. EXT WALL W/BRICK OR STONE VENEER ... 48PSF (40PSF MAX VENEER WT, 3 5/8" MAX VENEER THK) 116.3. INT WALLS: 116.3.1. INT WALLS W/GYP...8PSF 116.3.2. INT WALLS WITH PLASTER ON ONE SIDE ... 14PSF 116.3.3. INT WALLS WITH PLASTER ON TWO SIDES...20PSF 116.4. ROOF: 116.4.1. RAFTERS W/SHINGLE OR METAL COVERING ... 12PSF 116.4.2. RAFTERS W/TILE COVERING ... 2OPSF (12PSF MAX TILE WEIGHT) 116.4.3. TRUSSES W/SHINGLE OR METAL COVERING ... 15PSF TOP CHORD, 5 PSF BOT CHORD 116.4.4. TRUSSES W/TILE COVERING ... 23PSF TOP CHORD, 5 PSF BOT CHORD 116.4.5. RAFTERS OR TRUSSES WITH PLASTER CEILING DIRECTLY APPLIED TO THE BOTTOM SHALL BE DESIGNED FOR ADDITIONAL 8PSF (APPLIED TO BOT CHORD FOR TRUSS ASSEMBLIES) 116.5. CEILING FRAMING 116.5.1. W/LIMITED STORAGE ... IOPSF 116.5.2. W/OUT STORAGE ... 5PSF 116.5.3, W/PLASTER FINISH ... 2OPSF 116.6. FLOOR FRAMING 116.6.1. W/HARDWOOD OR CARPET FINISHES ... 12PSF 116.6.2. W/THIN-SET CERAMIC TILE FINISHES ... 17PSF 116.6.3, W/STONE OR MARBLE TILE ON FULL MORTAR BED ... 41PSF 116.6.4. TRUSS FLOOR FRAMING SHALL HAVE ADDITIONAL 5PSF APPLIED TO THE BOTTOM CHORD. 116.6.5. FLOOR FRAMING W/PLASTER CEILING DIRECTLY APPLIED TO THE BOTTOM SHALL BE DESIGNED FOR ADDITIONAL 8PSF (APPLIED TO BOT CHORD FOR TRUSS ASSEMBLIES). 116.6.6. W/LIGHTWEIGHT CONCRETE TOPPING ... ADDT 1OPSF DEAD LOAD PER INCH OF LWC THICKNESS APPLIED TO THE TOP OF THE FLOOR ASSEMBLY. 116.6.7, W/NORMAL WEIGHT CONCRETE TOPPING ... ADDT 12.5PSF DEAD LOAD PER INCH OF NWC THICKNESS APPLIED TO THE TOP OF THE FLOOR ASSEMBLY. 116.7. ENGINEERED PLANS PREPARED BY LONGITUDE 120 ENGINEERING AND DESIGN ARE GENERALLY DESIGNED FOR SHINGLE OR METAL ROOF COVERINGS, INTERIOR GYPSUM BOARD FINISHES, AND CERAMIC TILE, CARPET, OR WOOD FLOOR COVERINGS. PROJECTS INCORPORATING TILE ROOFING, INTERIOR PLASTER FINISHES, AND/OR MARBLE OR STONE TILE ON FULL MORTAR BED WILL INCLUDE A SPECIFIC NOTE ON THE PLANS INDICATING THAT THE FRAMING HAS BEEN DESIGNED TO MEET MORE STRINGENT STRUCTURAL REQUIREMENTS ASSOCIATED WITH HEAVIER AND/OR MORE BRITTLE MATERIALS. IF NO SUCH NOTE IS PROVIDED ON THE PLANS, THE CONTRACTOR SHALL NOTIFY FOR UPON REVIEW OF THE PROJECT AND PRIOR THE COMMENCEMENT OF CONSTRUCTION TO ALLOW ADEQUATE TIME FOR ANY NECESSARY DESIGN MODIFICATIONS. 117. LIVE LOADS 117.1. DESIGN LIVE LOADS SHALL CONFORM TO THE APPLICABLE BUILDING CODE AND ASCE 7 UNLESS SPECIFICALLY NOTED ON THE STRUCTURAL DRAWINGS FOR ADDITIONAL REQUIREMENTS. THE FOLLOWING DESIGN LIVE LOADS SHALL BE USED FOR THE STRUCTURE AS APPLICABLE. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL REVIEW THESE VALUES AND NOTIFY THE FOR IMMEDIATELY IF THEY DO NOT CONFORM WITH THE INTENDED USE OF ANY SPACE. 117.1.1. ROOF ... 20PSF 117.1.2. CEILING WITH LIMITED STORAGE ... 20PSF (TYPICAL) 117.1.3. CEILING WITHOUT STORAGE ... 1OPSF (ONLY WHEN MEETS IRC NON STORAGE CRITERIA) 117.1.4. CEILING WITH STORAGE ACCESSIBLE BY FIXED STAIR OR FULL SIZE DOOR ... 3OPSF 117.1.5. FLOOR ... 4OPSF 117.1.6. GARAGE ... 4OPSF OR 3,OOOLBS OVER 4.5"X4.5" AREA (NON CONCURRENT) 117.1.7. BALCONY/DECK ... 4OPSF 117.1.8. RAILING ... 50PLF UNIFORM OR 200LBS (NON CONCURRENT). LOAD SHALL BE APPLIED IN THE DIRECTION PRODUCING THE MAXIMUM EFFECT, TYPICALLY HORIZONTALLY. 118. DEFLECTION LIMITS 118.1. DEFLECTION LIMITS SHALL BE LIMITED TO THE MOST STRINGENT CRITERIA THAT IS APPLICABLE FOR THE DESIGN. MAX DEFLECTION LIMITS BELOW ARE BASED ON TOTAL LOAD DEFLECTION UNLESS INDIVIDUALLY SPECIFIED BASED ON LIVE LOAD (LL) OR TOTAL LOAD (TOTAL). TOTAL LOAD DEFLECTION CRITERIA MUST ACCOUNT FOR ALL LOAD FOR THE PARTICULAR MEMBER INCLUDING BUT NOT LIMITED TO LIVE LOAD, DEAD LOAD, ROOF LOAD, SNOW LOAD, WIND LOAD, SEISMIC LOAD, AND ETC: 118.1.1. ROOF: 118.1.1.1. RAFTERS W/SLOPES GREATER THAN 3:12 W/SHINGLE OR METAL COVERING... L/180 118.1.1.2. RAFTERS W/ SLOPES 3:12 OR LESS W/SHINGLE, METAL, OR TPO COVERING... L/240 118.1.1.3. RAFTERS W/TILE COVERING ... L/240 118.1.1.4. RAFTERS W/GYP CEILING DIRECTLY ATTACHED... L/240 118.1.1.5. RAFTERS W/PLASTER CEILING DIRECTLY ATTACHED ... L/360 118.1.1.6. ROOF TRUSSES...L/360 (LL) L/240 (TOTAL) 118.1.1.7. ROOF SCISSOR TRUSSES ... U600 118.1.2. CEILING 118.1.2.1. CEILING JOISTS .... L/240 118.1.2.2. CEILING JOISTS W/PLASTER CEILING...U360 118.1.3. FLOORS 118.1.3.1. FLOORS W/FLEXIBLE COVERING ... L/480 (LL), L/240 (TOTAL) 118.1.3.2. FLOORS W/THINSET CERAMIC TILE ... L/480 (LL), L/360 (TOTAL) 118.1.3.3. FLOORS SUPPORTING STONE OR MARBLE TILE ON FULL MORTAR BED.... L/720 OR 7/32" MAX WHICHEVER IS MORE STRINGENT 118.1.4. FRAMING SUPPORTING MASONRY VENEER... L/600 118.1.5. HEADERS 118.1.5.1. HEADERS SHALL HAVE THE SAME DEFLECTION CRITERIA TO FLOORS SECTION ABOVE BASED ON THE TYPE OF MATERIAL/APPLICABLE FINISHES IT SUPPORTS 118.1.5.2. TYP HEADER ... L/480 (LL), 1.1360 (TOTAL) 118.1.5.3. HEADERS AT SLIDING DOORS ... L/600 118.1.6. WALLS 118.1.6.1. EXT STUDS W/FLEXIBLE COVERINGS ... H/180 118.1.6.2. EXT STUDS W/EXT BRICK VENEER ... H/240 118.1.6.3. EXT STUDS W/STUCCO... H/360 118.1.6.4. EXT STUDS W/INT FACE COVERED W/PLASTER... H/360 NO MATTER EXTERIOR COVERING 118.1.6.5. INT STUDS W/GYP... H/180 118.1.6.6. INT STUDS W/PLASTER... H/360 118.2. REF NOTE 116.7 REGARDING TILE ROOFING, PLASTER FINISHES, AND STONE/MARBLE TILE APPLICATIONS. 119. DIMENSIONS AND LENGTH 119.1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ELEVATIONS BEFORE STARTING WORK. ANY DISCREPANCIES BETWEEN THESE STRUCTURAL DRAWINGS AND ANY OTHER DRAWINGS SHALL BE REPORTED PER NOTE 100.2. 119.2. ALL DIMENSIONS SHOWN ON THIS PLAN ARE FOR REFERENCE ONLY. DIMENSIONS ARE DERIVED FROM THE ARCHITECTURAL DRAWINGS, WHICH SHALL BE CONSIDERED THE GOVERNING SOURCE FOR ALL MEASUREMENTS. WORKING DIMENSIONS OR MATERIAL TAKE OFF SHALL NOT BE SCALED FROM PLANS, SECTIONS, OR DETAILS ON THESE DRAWINGS. 120. DELEGATED DESIGN 120.1. WHERE THE STRUCTURAL DRAWINGS INDICATE ELEMENTS ARE TO BE DESIGNED BY OTHERS OR 'DELEGATED DESIGN,' THE CONTRACTOR SHALL RETAIN A LICENSED ENGINEER TO PREPARE AND SEAL DESIGN DOCUMENTS FOR THOSE ELEMENTS. DELEGATED DESIGN DOCUMENTS SHALL BE SUBMITTED TO THE FOR FOR REVIEW PRIOR TO FABRICATION OR INSTALLATION. REVIEW BY THE FOR IS FOR GENERAL CONFORMANCE WITH THE STRUCTURAL INTENT ONLY AND DOES NOT RELIEVE THE DELEGATED ENGINEER OF RESPONSIBILITY FOR THEIR DESIGN. 120.2. WHERE THE DELEGATED DESIGN INCORPORATES LOADS SHOWN ON THE STRUCTURAL DRAWINGS, THOSE LOADS SHALL BE CONSIDERED ASD (ALLOWABLE STRESS DESIGN) LEVEL. 121. SHOP DRAWINGS AND SUBMITTALS 121.1. REVIEW OF SUBMITTALS AND SHOP DRAWINGS IS FOR GENERAL CONFORMANCE WITH THE STRUCTURAL DRAWINGS AND PROJECT SPECIFICATIONS, NOT FOR DIMENSION CONTROL. THE ENGINEER SHALL BE ENTITLED TO RELY ON THE ACCURACY AND COMPLETENESS OF INFORMATION PROVIDED BY THE CONTRACTOR, THE ARCHITECT, OR OTHER THIRD PARTY. 121.2. ALL DISCREPANCIES BETWEEN SHOP DRAWINGS AND STRUCTURAL PLANS SHALL BE REPORTED IN WRITING TO THE FOR AT THE TIME OF SUBMITTAL. 121.3. AN ELECTRONICPY F H P DRAWINGS FOR THE FOLLOWING ELEMENT ARE REQUIRED T BE 3 CO O SHOP GS 0 S QU 0 SUBMITTED TO FOR FOR REVIEW AND APPROVAL PRIOR TO FABRICATION: 121.3.1. PRE -MANUFACTURED WOOD TRUSSES L 121.3.2. -LAMINATED TIMBER ELEMENT 3 GU S 121.3.3. STRUCTURAL AND MISCELLANEOUS STEEL 121.3.4. CONCRETE DESIGN MIX 121.3.5. EPDXY ADHESIVES 121.3.6. HELICAL PILES 122. ALTERNATES 122.1. ALTERNATE ASSEMBLIES AND MATERIALS MAY BE SUBMITTED FOR REVIEW; HOWEVER, ACCEPTANCE IS NOT GUARANTEED. THE ENGINEER RESERVES THE RIGHT TO REQUIRE COMPENSATION FOR TIME SPENT REVIEWING SUCH ALTERNATES. 123. INSPECTIONS/OBSERVATIONS 123.1. INSPECTIONS SHALL BE IN CONFORMANCE WITH THE PROVISIONS OF IBC SECTION 110 OR IRC SECTION R109. 123.2. INSPECTIONS ARE GENERALLY CONDUCTED BY QUALIFIED INSPECTORS REPRESENTING EITHER THE ENGINEER OR A THIRD PARTY TO VERIFY THAT MATERIALS INSTALLATION IS IN SUBSTANTIAL CONFORMANCE WITH THE STRUCTURAL PLANS AND SPECIFICATIONS, OR TO VERIFY ACTUAL FIELD CONDITIONS AS THE BASIS FOR FIELD CHANGES OR REPAIRS. INSPECTIONS ARE REPRESENTATIVE OF THE CONSTRUCTION AND ARE NOT MEANT TO ENSURE COMPLETE COMPLIANCE. A COPY OF INSPECTION COMMENTS WILL GENERALLY BE PROVIDED TO THE CONTRACTOR REFLECTING DISCREPANCIES NOTED; NO OTHER OBSERVATIONS ARE TO BE IMPLIED OR INFERRED. INSPECTIONS DO NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY TO COMPLY WITH THE APPROVED PLANS OR CONTRACT DOCUMENTS. 123.3. REVISIONS, REPAIRS AND FIELD CHANGES ARE AUTHORIZED ONLY WHEN IN WRITING, SIGNED AND SEALED BY A PROFESSIONAL ENGINEER WITH THIS OFFICE. WHEN SO ISSUED, THEY BECOME INCORPORATED INTO THE PLANS AND CONTRACT DOCUMENTS. 124. SITE VISITS 124.1. SITE VISITS ARE TO OBSERVE GENERAL PROGRESS AND QUALITY OF CONSTRUCTION AND ARE NOT INTENDED AS DETAILED INSPECTIONS, NOR DO THEY IMPLY EXHAUSTIVE REVIEW OF ALL WORK OR CODE COMPLIANCE, THE ENGINEER MAKES NO WARRANTY OR GUARANTEE REGARDING THE CONDITION, PERFORMANCE, OR CODE COMPLIANCE OF THE WORK OBSERVED. 125. SPECIAL INSPECTIONS 125.1. WHERE REQUIRED BY THE APPLICABLE BUILDING CODE, A STATEMENT OF SPECIAL INSPECTIONS SHALL BE PREPARED IN ACCORDANCE WITH IBC SECTION 1705 AND SUBMITTED TO THE AUTHORITY HAVING JURISDICTION (AHJ) PRIOR TO PERMIT ISSUANCE. SPECIAL INSPECTIONS ARE SEPARATE FROM AND IN ADDITION TO THE GENERAL INSPECTIONS REFERENCED IN NOTE 123. 125.2. THE CONTRACTOR, OR OWNER, OR OWNER'S REPRESENTATIVE SHALL EMPLOY A SPECIAL INSPECTOR TO PERFORM REQUIRED INSPECTIONS. THE SPECIAL INSPECTOR SHALL SUBMIT REPORTS TO THE EOR, ARCHITECT, AND AHJ AS REQUIRED, WITH A FINAL REPORT SUBMITTED TO THE AHJ PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. 126. WATERPROOFING 126A. WATERPROOFING, MOISTURE PROOFING, FLASHING, SEALANTS, AND RELATED DETAILS ARE NOT INCLUDED IN THE STRUCTURAL SCOPE AND SHALL BE DESIGNED BY OTHERS. THE CONTRACTOR SHALL COORDINATE WITH APPLICABLE TRADES AND REPORT ANY CONFLICTS WITH THE STRUCTURAL DESIGN TO THE FOR PRIOR TO CONSTRUCTION. CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 07/07/2026 9:21:07 AM BY: KELLY TAFT TSBPE: 1-3971 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY ALL CHANGES MUST BE APPROVED. F j4, * * ........................... .ALIAKSEI PATSEVICH ........................... ,o %�4,,o 130521 r • N• ` n ..... %C' S ••• S G N 1 O E N ice_ AL w :) 0 Z 0 J r •71! _O 2 ad 2 iz W W Z_ 2 W M IT .4 0 J* 1-1 LL- J Lu I- m 2: °' O o U ko L7 x Z I- '-' ce LLJ Lu LuZ z ,__, Lu a Z W C)j� o C_9 .--i r,� -i ,'I- _ ,--i U x '-' O Lu CI, U) '. Q L 0- 0 1- 4 co fV Lf [V to Nr .--i [V REVISIONS 0 DATE BY PROJECT NAME 101 CROSS CREEK GARAGE ADDITION 101 CROSS CREEK DR GRAPEVINE, TX PROJECT NUMBER S26129 CHECKED BY - AP SHEET DATE - 05/04/2026 Z _O t U-) w 0 SCALE 24X36 SHEET:1/2"=1'-0" (n LLJ 0 z _J af of (n -J 9 z Lu 0 Lu 2 Ln GN301. GENERAL FRAMING NOTES, TYP DETAILS, AND SCHEDULES 301. GENERAL 301.1. REFER TO GENERAL STRUCTURAL NOTES (SECTIONS 100 THROUGH 127) FOR ALL ADDITIONAL REQUIREMENTS APPLICABLE TO MATERIALS, FASTENERS, CONNECTORS, INSPECTIONS, DELEGATED DESIGN, SUBMITTALS, AND ALL OTHER WORK NOT SPECIFICALLY ADDRESSED IN THESE FRAMING NOTES. IN CASES OF CONFLICT THE MORE STRINGENT REQUIREMENT SHALL GOVERN PER NOTE 100.4. 301.2. FRAMING SHALL CONFORM WITH THE APPLICABLE BUILDING CODE AND THE WOOD FRAME CONSTRUCTION MANUAL (WFCM) PUBLISHED BY THE AMERICAN WOOD COUNCIL (AWC). 301.3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ELEVATIONS WITH THE ARCHITECTURAL DRAWINGS PRIOR TO CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED IN WRITING TO THE ARCHITECT AND THE FOR PRIOR TO CONSTRUCTION OF THE AFFECTED WORK. (SEE NOTE 100.2). 301.4. THE CONTRACTOR SHALL LOCATE ALL OPENINGS AND PENETRATIONS AND VERIFY NO CONFLICT WITH STRUCTURAL FRAMING PRIOR TO CONSTRUCTION. MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS ARE BY OTHERS. SEE SECTION 304 FOR FRAMING PENETRATION REQUIREMENTS. 301.5. FIREBLOCKING AND DRAFTSTOPPING REQUIREMENTS ARE BY OTHERS AND SHALL CONFORM WITH THE APPLICABLE BUILDING CODE. 301.6. STANDARD NOTES DETAILS AND SCHEDULES ARE GUIDELINES FOR TYPICAL CONDITIONS. WHERE SPECIFIC NOTES, DETAILS, OR SCHEDULES ARE SHOWN ON THE PLANS, THOSE SHALL GOVERN. (SEE NOTE 100.4). 302. FASTENERS 302.1. ALL FASTENER REQUIREMENTS -- INCLUDING CORROSION PROTECTION FOR FASTENERS IN CONTACT WITH PRESSURE -TREATED (PT) OR FIRE -RETARDANT -TREATED (FRT) WOOD, GALVANIZATION STANDARDS, STAINLESS STEEL GRADES, AND PROHIBITED FASTENER TYPES -- SHALL BE PER NOTES 110.1 THROUGH 110.12 OF THE GENERAL STRUCTURAL NOTES. 302.2. NAILS SHALL BE COMMON OR SINKER NAILS UNLESS NOTED OTHERWISE, PNEUMATICALLY DRIVEN NAILS SHALL MATCH THE REQUIRED LENGTH AND DIAMETER OF THE SPECIFIED NAIL AND SHALL MEET THE REQUIREMENTS OF NOTE 110.4. 302.3. TYPICAL NAIL SIZE: 0.131"X2-1/2", 0.131"x3", 0.131"x3-1/2", 0.148"x3", 0.148"x3-1/4", 0.162"X3-1/2". ADDITIONAL SIZES MAY BE REQUIRED PER SPECIFIC PLAN OR DETAIL CALLOUTS. 302.4. EDGE DISTANCES, END DISTANCES, AND FASTENER SPACING SHALL BE SUFFICIENT TO PREVENT SPLITTING OF THE WOOD PER NDS REQUIREMENTS. TOE NAILS SHALL BE DRIVEN AT AN APPROXIMATE 300 ANGLE WITH THE MEMBER AND STARTED APPROXIMATELY 1/3 NAIL LENGTH FROM THE MEMBER END. 302.5. AT SHEATHING NAILING, IF MORE THAN 20% OF NAILS IN ANY PANEL ARE OVERDRIVEN BY MORE THAN 1/16% PROVIDE ONE ADDITIONAL NAIL FOR EVERY TWO OVERDRIVEN NAILS. 302.6. NAILS AT MECHANICAL CONNECTORS SHALL COMPLY WITH THE TYPE, SIZE, AND QUANTITY SPECIFIED BY THE CONNECTOR MANUFACTURER TO ACHIEVE THE MAXIMUM SPECIFIED LOAD CAPACITY. ALL CONNECTOR FASTENER REQUIREMENTS AND SUBSTITUTION RESTRICTIONS ARE PER NOTES 111.4 AND 111.5. 302.7. TYPICAL NAILING REQUIREMENTS SHALL BE AS SPECIFIED PER IBC TABLE 2304.10.1, IRC TABLE R602.3(1) OR PER THE TYPICAL NAILING SCHEDULE BELOW, UNLESS NOTED OTHERWISE PER PLAN, SHEAR WALL SCHEDULE (NOTE 409), OR SPECIFIC DETAILS. 302.8. TYPICAL NAILING SCHEDULE: TYPICAL NAILING SCHEDULE (5) BLOCKING BETWEEN RAFTERS TO TOP PLATE('') TOE NAIL 3"XO.131" @ 6" O.C. (MIN 3) "I I CEILING JOISTS TO TOP PLATE TOE NAIL (3) 3"XO.131", PER JOIST I CEILING JOISTS TO RAFTER OR LAPS OVER PARTITION FACE NAIL (4) 3"XO.131" I COLLAR TIE TO RAFTER FACE NAIL (4) 3"XO.131" ROOF I RAFTER OR ROOF TRUSS TO TOP PLATE AT BEARING WALL TOE NAIL (4) 3"XO.131'. TWO PER SIDE, ADD'L HZJ') AND CEILING ROOF RAFTERS TO RIDGE, VALLEY OR HIP TOE NAIL (4) 3"XO.131" OR END NAIL (3) 3"X0.131' TYPICAL: 2-1/2"X0.131" Ca) 6" O.C. EDGE, C& 12" O.C. FIELD ROOF SHEATHING TO RAFTER OR TRUSS WITHIN 4'-O" FROM EAVES, VALLEYS, HIPS AND RIDGES: 6" O.C. FIELD TO GABLE END WALLS: 4" O.C. ROOF BRACE TO TOP PLATE TOE NAIL (4) 3"XC.131". TWO PER SIDE BUILT-UP STUDS FACE NAIL 3"X0.131" @ 6"O.C. STAGGERED ABUTTING STUDS AT INTERSECTING WALL CORNERS FACE NAIL 3"XO.131" @ 6"O.C. BUILT-UP MULTIPLY HEADER HEADER, SAWN LUMBER 2X FACE NAIL 3-1/2"X0.162" @ 12"O.C. ALONG EA EDGE, EA PLY OF PIECES WITH MAX 1/2" SPACER HEADER"' I BUILT-UP MULTI -PLY HEADER, ENGINEERED LUMBER REF ENGINEERED LUMBER NAILING DETAIL I CONTINUOUS HEADER TO STUD TOE NAIL (4) 2-1/2"X0.131" I ADJACENT FULL -HEIGHT KING STUD TO END OF HEADER END NAIL (6) 3"XO.131" WALL I TOP PLATE TO TOP PLATE FACE NAIL 3"XO.131" @ 12" O.C. DOUPLE TOP PLATE LAP SPLICE MINIMUM 24" LAP SPLICE LENGTH WITH MINIMUM (12) 3"X0.131" IN LAPPED AREA I TOP PLATES LAP AT CORNERS AND INTERSECTIONS FACE NAIL (3) 3"X0.131" I BOTTOM PLATE TO RIM, JOIST OR BLOCKING ('1(B) FACE NAIL 3-1/2"10.131" @ 12" CI TOP OR BOTTOM PLATE TO STUD (Bl TOE NAIL (4) 3"X0.131" (B) OR END NAIL (3) 3"10.131"(B) WALL SHEATHING TO WALL STUDS FACE NAIL 2 1/2"XO.131" @ 6" O.C. EDGE, @ 12" O.C. FIELD MAX (Sl(1) JOISTS TO TOP OF PLATE OR TOP OF BEAM/GIRDER TOE NAIL (3) 3"X0.131", OR FLANGE NAIL AT 1-JOISTS I RIM JOIST, BAND JOIST OR BLOCKING TO PLATE BELOW TOE NAIL 3"X0.131" @ 6" O.C. MAX (MIN 3) r596) I RIM JOIST TO END OF FLOOR JOISTS FACE NAIL (1) 3"XD.131" TOP AND BOT FLANGE FLOOR SHEATHING (3/4" MAX THICKNESS) TO FLOOR FACE NAIL 2 1/2"10.131" @ 6" O.C. EDGE, @ 12" O.C. FIELD (6) FLOOR JOISTS OR BLOCKING FLOOR SHEATHING (7/8" MIN - 1 1/4" MAX) TO FLOOR FACE NAIL 3"XO.148" @ 6" O.C. EDGE, @ 12" O.C. FIELD 16) JOISTS OR BLOCKING I BRIDGING OR BLOCKING TO ADJACENT JOIST OR TRUSS TOE NAIL (2) 3"XO.131" EA END RIM TO JOIST END NAIL (4) 3"XO.131" BUILT-UP MULTI -PLY 2X BEAMS FACE NAIL 3-1/2"10.162" @ 12"O.C. ALONG EA EDGE, EA PLY OF HEADER"' BUILT-UP MULTI -PLY ENGINEERED LUMBER BEAM REF ENGINEERED LUMBER FASTENING NOTE 303.12.2 NOTES: (1) ALL NAILS SHALL BE OF THE SIZE AND TYPE SPECIFIED. (2) SUBSTITUTION WITH PNEUMATICALLY DRIVEN NAILS 15 PERMITTED, PROVIDED THEY MATCH THE SPECIFIED LENGTH AND DIAMETER, AND MEET THE EQUIVALENT STRENGTH REQUIREMENTS OUTLINED IN THE FRAMING AND GENERAL NOTES. (3) PROVIDE H2.5 TIE AT RAFTER OR TRUSS TO T/PLATE CONNECTION. 4 OFFSET NAILS MIN 3" AT EACH ADJACENT PLY. (5) REFER TO SHEARWALL SCHEDULE FOR NAILING REQUIREMENTS AT SHEARWALLS. (6) WHERE FLOOR FRAMING OCCURS OVER SHEARWALL, FLOOR SHEATHING TO RIM OR BLOCKING CONNECTIONS SHALL CONFORM TO THE NAILING REQUIREMENTS SPECIFIED IN THE SHEARWALL SCHEDULE. (7) 12" O.C. FIELD NAILING IS ACCEPTABLE FOR STUDS SPACED AT 16" O.C. OR LESS. WHEN STUDS ARE SPACED APART MORE THAN 16" O.C. FIELD NAILING SHALL BE 6" O.C. (8) ADDITIONAL NAILS REQUIRED AT EXTERIOR WALLS TALLER THAN 10'4". REFER TO EXT WALL STUD SCHEDULE (NOTE 309.10.1) 303. GENERAL FRAMING 303.1. ALL LUMBER, SHEATHING, AND SIDING LOCATED LESS THAN 6 INCHES FROM FINISHED GRADE, EXPOSED TO WEATHER, OR IN DIRECT CONTACT WITH CONCRETE SHALL BE PRESERVATIVE -TREATED PER NOTE 103.5. FIELD CUTS, NOTCHES, AND DRILLED HOLES IN TREATED LUMBER SHALL BE TREATED IN THE FIELD PER AWPA M4. 303.2. DIMENSIONAL LUMBER SHALL MEET THE REQUIREMENTS OF NOTE 103. SPECIES AND MINIMUM REQUIRED GRADES FOR THIS PROJECT SHALL BE AS FOLLOWS: 303.2.1. SPECIES: SOUTHERN YELLOW PINE (SYP) 303.2.2. GRADE: SAWN MEMBER MINIMUM GRADE STUDS PER WALL STUD SCHEDULE, #2 GRADE REQUIRED AT PORTAL FRAMES PLATES (TOP AND SILL) #3 OR BETTER FLOOR JOISTS #2 OR BETTER RAFTERS, HIPS, VALLEYS, RIDGES #2 OR BETTER ROOF BRACES, PURLINS, COLLAR TIES #2 OR BETTER BEAMS, HEADERS (SAWN) #2 OR BETTER POSTS, COLUMNS (SAWN) #2 OR BETTER 303.3. ENGINEERED WOOD PRODUCTS SHALL MEET THE MANUFACTURING, LABELING, INSTALLATION, STORAGE, AND FIELD MODIFICATION REQUIREMENTS OF NOTES 104.1 THROUGH 104,9 (EWP) AND NOTES 105.1 THROUGH 105.7 (GLULAM). MINIMUM GRADES FOR THIS PROJECT SHALL BE AS FOLLOWS: ENGINEERED WOOD PRODUCT MINIMUM GRADE/SPECIFICATION NOTES I RIM BOARD 1-1/4" LSL 1.3E (TYPICAL) 1-1/2" LSL (1.5E) OR 1-3/4" LSL (1.55E) MAY BE REQUIRED AT SHEARWALLS. REF SHEARWALL SCHEDULE LVL HEADERS, BEAMS, JOISTS LVL 2,OE MIN I LSL HEADERS, BEAMS, JOISTS LSL 1.55E MIN I PSL HEADERS, BEAMS PSL 2.2E MIN LSL STUDS LSL 1.3E (1-1/2" WIDE) LSL 1.55E (1-3/4" WIDE) PSL COLUMNS PSL 1.8E MIN 24F-V4 DF (SINGLE SPAN) GLULAM 24F-V8 OF (MULTISPAN OR CANTILEVER) 303.4. SHEATHING PANEL GRADES AND THICKNESS - UNLESS OTHERWISE NOTED, PANELS SHALL BE AS FOLLOWS: APPLICATION MINIMUM PERFORMANCE MIN SPAN RATING ADDITIONAL NOTES CATEGORY WALL SHEATHING 7/16" 24/16 EXPOSURE 1 I ROOF SHEATHING - SHINGLE/METAL 7/16" 24/16 EXPOSURE 1 ROOF SHEATHING -TILE 15/32" 32/16 EXPOSURE 1 FLOOR SHEATHING 23/32" 48/24 EXPOSURE 1, T&G, GLUED AND NAILED I DECK SHEATHING EXPOSED TO WEATHER 23/32" 48/24 EXTERIOR RATED, T&G, REF NOTE 108.3 1 303.5. FRAMING SHALL PROVIDE A CONTINUOUS LOAD PATH TO TRANSFER ALL VERTICAL AND LATERAL LOADS FROM THE ROOF, WALL, CEILING, AND FLOOR SYSTEMS TO THE FOUNDATION. 303.6. WHERE JOISTS, TRUSSES, OR RAFTERS ARE SPACED MORE THAN 16" O.C. AND THE BEARING STUDS BELOW ARE SPACED AT 24" O.C., SUCH MEMBERS SHALL BEAR WITHIN 5" OF THE STUDS BENEATH. 303.7. ALL BEAMS SHALL BE SUPPORTED AT EACH END BY BUNDLED STUDS (MINIMUM 2) OR A POST WHOSE COMBINED WIDTH EQUALS OR EXCEEDS THE FULL WIDTH OF THE BEAM, UNO. EACH BEAM SUPPORT SHALL HAVE A CONTINUOUS LOAD PATH TO THE FOUNDATION OR TO ADEQUATELY SIZED SUPPORTING BEAMS OR HEADERS BELOW. FOR PROJECTS WITH FLOOR FRAMING (MULTI -STORY OR CRAWLSPACE), VERTICAL SUPPORT SHALL BE CONTINUOUS THROUGH FLOOR FRAMING VIA VERTICAL CRUSH BLOCKING (VCB). SEE NOTE 307.11. 303.8. BEAM FRAMING ELEVATION NOTATION PER PLAN 303.8.1. "DROPPED BEAM" or "DB": TOP OF BEAM EQUAL TO BOTTOM OF JOISTS. 303.8.2. "TOP FLUSH" or "TF": TOP OF BEAM EQUAL TO TOP OF JOISTS; BOTTOM VARIES. 303.8.3. "BOTTOM FLUSH" or "BF": BOTTOM OF BEAM EQUAL TO BOTTOM OF JOISTS; TOP VARIES. 303.9. FRAMING ELEVATION DEFAULTS (UNO PER PLAN): FLOOR BEAMS - TOP FLUSH. CEILING BEAMS - BOTTOM FLUSH. PORCH / PATIO / BALCONY BEAMS - DROPPED. ROOF BEAMS - TOP FLUSH. 303.10. BEAMS SHALL HAVE FULL BEARING OVER TOP PLATES. WHERE BEAMS ON OPPOSITE SIDES OF A WALL ARE IN LINE, EACH SHALL HAVE 1/2 PLATE WIDTH FOR BEARING, UNO PER PLAN. AT PERIMETER WALLS, BEAMS SHALL HAVE FULL BEARING LESS RIM BOARD WHERE APPLICABLE. UNDER NO CIRCUMSTANCES SHALL RAFTERS, JOISTS, BEAMS, OR GIRDERS BEAR LESS THAN 1-1/2" AT ANY SUPPORT. 303.11. HORIZONTAL STRAPS INDICATED ON FRAMING PLANS SHALL BE CENTERED OVER THE TOP PLATE, BEAM, OR BLOCKING, UNO. STRAP LENGTH PER PLAN. 303.12. MULTI -PLY BEAM AND HEADER FASTENING 303.12.1. ALL MULTI -PLY SAWN LUMBER 2x BEAMS SHALL BE FACE -NAILED TOGETHER PER THE TYPICAL NAILING SCHEDULE (NOTE 302.8). 303.12.2. ALL MULTI -PLY ENGINEERED LUMBER BEAMS SHALL BE CONNECTED TOGETHER AS FOLLOWS: FASTENERS SHALL BE STAGGERED WHEN REQUIRED ON BOTH SIDES EQ SPACING BETWEEN ROWS OF FASTENERS FASTENERS PER TABLE LOAD MUST BE APPLIED EVENLY ACROSS ENTIRE BEAM WIDTH. REF DETAIL FOR POINT LOAD CONNECTION AT MULTIPLY BEAMS AT BEAM TO BEAM CONNECTION. FASTENER INSTALLATION REQUIREMENTS FOR MULTIPLE PLY LVL BEAMS FASTENERS MAX UNIFORM LOAD PLY # OF TOTAL ASSEMBLY SECTION WIDTH PLIES WIDTH FASTENER TYPE # ROWS MAX 0 C LOCATION APPLIED TO EITHER (') SIDE MEMBER PLF SPACING 10D (3"X0.148") 3 1'-0" ONE FACE 865 ,_ 1/2" DIA THROUGH BOLT(') 2 2-0" - 780 2 3-1/2" 111���� 160 SINKER (3 1/4" X 0.148') 2(2) 1'-0" ONE FACE 575 / 865(') SDS SCREW (3-1/2"X1/4") 2 T-0" ONE FACE 870 SDW22 SCREW (3-3/8-XC.22") 2 2'-0" ONE FACE 680 lOD (3"X0.148") 3 V-W BOTH FACES 110 1/1" DIA THROUGH BOLT"') 2 V-4" - 880 3 5-1/4" III��� ,[ 16D SINKER (3 1/4" X 0.148") 2i2) 1'-0" BOTH FACES 430 / 650(') SDS SCREW (3-1/2"Xl/4") I= 2 V-4" BOTH FACES 980 SDW22 SCREW (5"X0.2V) 2 1'-4" ONE FACE 935 1-3/4" LVL � 112" DIA THROUGH BOLT{') 2 1'-4" - 780 4 7" Hl' SDS SCREW (3.1/2"X6") 2 l'-4" BOTH FACES 1,020 �, SDW22 SCREW (6-3/4"X0.22") 2 1,-4 , ONE FACE 830 1 1 1 1 1/2" DIA THROUGH BOLT(1) ----, 2 1'-0" - 820 5 8-3/4" ----, SDWS22800 SCREW (8'XO.22") 2 1'-0" BOTH FACES 400 (1) THROUGH BOLTS SHALL BE A307. PROVIDE STANDARD CUT WASHERS AND NUT. BOLT HOLES TO BE 9/16" MAX. (2) # OF ROWS SPECIFIED IS FOR BEAM DEPTHS OF 14" OR LESS. FOR BEAMS OVER 14" PROVIDE ADDITIONAL ROW OF FASTENERS (3) FOR APPLICATIONS WHERE APPLIED LOAD EXCEEDS MAX SPECIFIED LOAD, FASTENER SPACING CAN BE REDUCED TO V-0" AND INCREASED PROPORTIONALLY 303.13. AT BEAM TO BEAM CONNECTIONS, IN ADDITION TO THE FASTENERS REQUIRED FOR THE HANGER INSTALLATION, PROVIDE ADDITIONAL FASTENERS AS FOLLOWS: 4STENERS PER TABLE. BOTH SIDES OF BEAM BEAMS PER PLAN HANGER, AS REQUIRED FASTENER INSTALLATION REQUIREMENTS AT CONCENTRATED LOADS FOR MULTIPLE PLY LVL BEAMS FASTENERS MAX POINT LOAD PLY # OF TOTAL ASSEMBLY SECTION APPLIED TO EITHER PER FACE 13) WIDTH PLIES WIDTH FASTENER TYPE # FASTENERS LOCATIOW) SIDE MEMBER (LBS) _ IOD (3"X0.148") 12(1) ONE FACE 2,230 - I 16D SINKER (3 114" X 0.148") 12(1) ONE FACE 2,230 2 3 1/2" I SDS SCREW (3-1/2"X1/4") 4(2) ONE FACE 2,720 �Io SDW22 SCREW (3-3/8"XO.22") 4(2) ONE FACE 3,200 IOD (3"X0.148") 1211) BOTH FACES 1,675 3 5-1/4" I 16D SINKER 3 1/4" X 0.148" 12(') BOTH FACES 1,675 ,]I I SDS SCREW (3-1/2"XI/4") 4(2) BOTH FACES 2,040 1-3/4" � ' SDW22 SCREW (5"X0.22") 4(2) ONE FACE 1,800 LVL r`%% If SDS SCREW (3-1/2"X6") 4(2) BOTH FACES 2,225 4 7" l�, SDW22 SCREW (6-3/4"X0.2211) 4(2) ONE FACE 1,600 � I I I 1 5 8 3/4" I I SDWS22800 SCREW (8"XO.22") 16 BOTH FACES 3,200 Il � (1) # OF FASTENERS CANCREASEDI N BE IUP TO 24, MAX APPLIED POINT LOAD IS INCREASED PROPORTIONALLY TO THE ADDED FASTENERS. (2) # OF FASTENERS CAN BE INCREASED UP TO 8, 14AX APPLIED POINT LOAD IS INCREASED PROPORTIONALLY TO THE ADDED FASTENERS. (3) # OF FASTENERS SPECIFIED PER FACE SHALL BE EVENLY DISTRIBUTED ON BOTH SIDES OF THE HANGER. FOR EXAMPLE, IF 12 FASTENERS ARE REQUIRED, 6 SHALL BE INSTALLED ON THE LEFT SIDE AND 6 ON THE RIGHT SIDE OF THE HANGER. (4) WHEN FASTENER PLACEMENT LOCATION IS INDICATED AS "BOTH FACES," THE TOTAL NUMBER OF FASTENERS SHALL BE DOUBLED FROM THE QUANTITY SHOWN PER FACE 303.14. CONNECTORS AND HANGER SCHEDULES 303.14.1. ALL MECHANICAL CONNECTORS (JOIST HANGERS, STRAPS, POST BASES, HOLDOWNS, AND SIMILAR HARDWARE) SHALL MEET ALL REQUIREMENTS OF NOTES 111.1 THROUGH 111.9, INCLUDING CORROSION PROTECTION, MANUFACTURER APPROVAL, FASTENER COMPATIBILITY, AND INSTALLATION REQUIREMENTS. CONNECTOR SUBSTITUTIONS REQUIRE PRIOR WRITTEN APPROVAL FROM THE FOR PER NOTE 111.2 303.14.2. WHERE A HANGER IS INDICATED PER PLAN, HANGERS SHALL BE SELECTED FROM THE SCHEDULES BELOW UNLESS NOTED OTHERWISE ON THE PLANS OR IN SPECIFIC DETAILS. TYPICAL HANGERS SHALL BE REGULAR FACE -MOUNTED UNLESS OTHERWISE NOTED. 303.14.3. 2X SAWN LUMBER, 4X AND 6X TIMBER HANGER SCHEDULE: LUMBER HANGER SCHEDULE I TIMBER HANGER SCHEDULE REGULAR CONCEALED TOP FLANGE('' SLOPED I TIMBER REGULAR CONCEALED OP FLANGE;' SLOPED L SIZER I SIZE I MODEL NO. I MODEL NO. ITMODEL N0. I MODEL NO. MODEL NO . MODEL NO. MODEL NO. MODEL NO. 4X TIMBER 2X LUMBER I 4X6 LUS46 HUC46 WP46 - 2X6 LUS26 LUC26Z LB26 LRU26Z I 4X8 LUS48 HUC48 WP48 - 2X8 LUS28 LUC26Z LB28 LRU28Z I 4X10 LU5410 HUC410 BA410 LSSR410Z 2X10 LUS210 LUC210Z LB210AZ LRU21OZ I 4XI2 LUS410 HUC412 BA412 . 2X12 LUS210 LUC210Z L6212AZ LRU212Z I 6X TIMBER 2-PLY 2X LUMBER I 6X6 U66 HUC66 WP66 - 2-PLY 2X6 LUS26-2 HUC26-2 WP26-2 - I 6X8 U66 HUC68 WP68 . 2-PLY 2X8 LUS28-2 HUC28-2 WP28-2 - I 6X10 U610 HUC610 WP610 - 2-PLY 2X10 LUS210-2 HUC210-2 WP210-2 LSSR210-2Z I 6X12 HU612 HUC612 HWPH612 - 2-PLY 2X12 WS210-2 HUC212-2 WP212-2 - I NOTES: 3 PLY 2X LUMBER (1) FOR INSTALLATION OVER WOOD NAILER ON TOP OF CONCRETE OR STEEL BEAMS FOLLOW MANUFACTURER REQUIREMENTS FOR 3-PLY 2X6 LUS26-3 HUC26-3 - QUANTITY AND LOCATION OF FASTENERS 3-PLY 2X8 LUS28-3 HUC26.3 - - 3-PLY 2X10 WS210.3 HUC210-3 3-PLY ZX12 W5210.3 HUC212.3 303.14.4. TJI JOIST AND ENGINEERED LUMBER HANGER SCHEDULE: TJI JOISTS HANGER SCHEDULE ENGINEERED LUMBER HANGER SCHEDULE (LVL, LSL, PSL) REGULAR TOP FLANGE^') SLOPED(2) REGULAR JOIST BEAM DEPTH BEAM WIDTH`3j SIZE MODEL NO. MODEL N0. MODEL N0. MODEL N0. 1 3/4" MIU1.81/9 210 SERIES 3 112' HHUS410 9 1/4" OR 9 1/2" 91/2" IUS2.06/9.5 ITS2.06/9.5 LSSR2.IZ 51/4" HGUS5.50/10 11 7/8" IUS2.06/11.88 ITS2.06/11.88 LSSR2.1Z 7" HGUS7.25/10 14" IUS2.06/14 ITS2.06/14 LSSR2.1Z 1 3/4" MIU1.81/11 16" IUS2.06/16 ITS2.06/16 LSSR2.1Z 3 112" HHU5410 11 1/4" OR 11 7/8" DOUBLE 9 1/2" MIU4.28/9 MIT4.28/9.5 LSU4.28 5 1/4" HGUS5.50/12 DOUBLE 11 7/8" MIU4.28/11 MIT4.28/11.88 LSU4.28 7" HGUS7.25/12 DOUBLE 14" MIU4.28/14 MIT4.28/14 LSU4.28 1 3/4" MIU1.81114 DOUBLE 16" MIU4.28/16 BA4.28/16 LSU4.28 3 112' HHUS410 230/360 SERIES 14" 5 1/4" HGUS5.50/14 91/2" IUS2.37/9.5 ITS2.37/9.5 LSSR2.37Z 7" HGUS7.25/14 11 7/8" IUS2.37/11.88 ITS2.37/11.88 LSSR2,37Z 1 3/4" MIU1.81/16 14" IUS2.37/14 ITS2.37/14 LSSR2.37Z 3 1/2" HGUS414 16" IUS2.37/16 ITS2.37/16 LSSR2.37Z 16" 5 1/4" HGUS5.50/14 DOUBLE 9 1/2" MIU4.75/9 MIT359.5-2 LSSR3510-2 7" HGUS7.25/14 DOUBLE 11 7/8" MIU4.75/11 MIT3511.88-2 LSSR3510-2 1 3/4" MIUI.81/18 DOUBLE 14" MIU4.75/14 MIT3514-2 LSSR3510-2 3 1/2" HGUS414 DOUBLE 16" MIU4.75/16 MIT4.75/16 LSSR3510-2 18" 5 1/4" HGUS5.50/14 560 SERIES 7" HGUS7.25/14 11 7/8" IUS3.56/11.88 ITS3.56/11.88 LSSR41OZ NOTES: 14" IU53.56/14 ITS3.56/14 LSSR41OZ (1) FOR INSTALLATION OVER WOOD NAILER ON TOP OF CONCRETE OR STEEL BEAMS FOLLOW MANUFACTURER REQUIREMENTS FOR QUANTITY 16" IUS3.56/16 ITS3.56/16 LSSR41OZ AND LOCATION OF FASTENERS DOUBLE 11 7/8" HU412-2 HB7.12/11.88 - (2) SLOPED HANGERS REQUIRE INSTALLATION OF 4" WEB STIFFENERS ON BOTH SIDES OF THE JOIST AT HANGER. ATTACH W/ (4) 0.148" DIA NAILS DOUBLE 14" HU414-2 HB7.12/14 - (3) AT BUILT-UP BEAMS HANGERS SHALL MATCH OVERALL WIDTH OF THE DOUBLE 16" HU414-2 H67.12/16 BUILT UP BEAM ASSEMBLY: 2-PLY 1 3/4" = 3 112" 3-PLY 1 3/4" = 5 1/4" 4-PLY 1 3/4" = 7" 303.15. CEILING/ATTIC FRAMING 303.15.1. TYPICAL CEILING AND ATTIC FRAMING IS BASED ON STANDARD SPAN TABLES FOR DIMENSIONAL LUMBER. THE CONTRACTOR SHALL VERIFY WHETHER ATTIC AREAS ARE DESIGNATED FOR LIMITED STORAGE OR NO STORAGE (SEE NOTE 117.1.2 AND 117.1.3 FOR APPLICABLE LIVE LOADS), AND SHALL CONFIRM THE LOCATION OF HVAC EQUIPMENT RELATIVE TO THESE AREAS. UNLESS SPECIFICALLY NOTED OTHERWISE ON THE CEILING FRAMING PLAN, ALL ATTIC AREAS CAPABLE OF ACCOMMODATING A BOX UP TO 42" IN HEIGHT AND 24" IN WIDTH SHALL BE CONSIDERED DESIGNED FOR LIMITED STORAGE, IF HVAC UNITS ARE LOCATED IN SPACES DESIGNATED FOR NO STORAGE, THE CONTRACTOR SHALL NOTIFY THE FOR FOR REVIEW PRIOR TO PROCEEDING. (SEE ALSO NOTES 106,9, 117.1.2, AND 117.1.3.) 303.15.2, PROVIDE ATTIC ACCESS OPENING MINIMUM 22"x30" FOR ATTIC AREAS WITH >_30" CLEAR HEIGHT OVER ?30 SF. LOCATE IN AN ACCESSIBLE LOCATION AND MAINTAIN MINIMUM 30" CLEAR HEADROOM ABOVE OPENING. 303.16. MAXIMUM ALLOWABLE LUMBER SPANS SHALL BE DETERMINED BASED ON THEIR DESIGNATED USE, SUPPORTED MATERIAL AND APPLICABLE DEFLECTION LIMITS PER NOTES 116 THROUGH 118. SPAN LIMITS SHALL BE AS FOLLOWS: LUMBER SPAN TABLE (SYP #2) SPACING (IN O.C.) APPLICATION SIZE I` 12 I 16 I 19.2 I 24 CEILING NOT ATTACHED TO RAFTERS DL=10PSF, LL=20PSF, U6=180 I 2X6 15'-7° 13'-6" 12'-3" 11'-0" I 2X8 19'-8" 17-1" 15'-7" 13'-11" RAFTERS WITH 2X10 23'-5" 20'-3" 18'-6" 16'-6" SHINGLE OR I 2X12 26-0" 23'-10" 21'-9" 19'-6" METAL ROOF I CEILING ATTACHED TO RAFTERS DL=20PSF, LL=20PSF, L/A=240 COVERINGS 2X6 13'-6° 11'-8" 10'-8" 9'-6" I 2X8 17-1" 14'-9" 13'-6" 12'-I" I 2X10 20'-3" 17-6" 16-0" 14'-4" 2X12 23'-10" 20'-8" 18'-10" 16-10" CEILING NOT ATTACHED TO RAFTERS DL=20PSF, LL=20PSF, L/A=180 I 2X6 13'-6' 11'-8" 10'-8" (') T-6• (1) I 2X8 17'-I" 14'-9" IT-6" (') 12'-1" (') I 2X10 20'-3" 17'-6" 16'-0" (') 14'-4" (') RAFTERS WITH I 2X12 2T-10" 20'-8" 18'-10" (') 16-1O" "' TILE ROOF COVERINGS I CEILING ATTACHED TO RAFTERS DL=25PSF, LL=20PSF, L/A=240 I 2X6 11'-6" 10'-6" 9'-6" (') 8'-6" (1) I 2X8 15'-4" IT-4" 12'-2" (1) 11'-0" (1) I 2X10 18'-6" 16'-0" 14'-6" (1) IT-0- (') 2X12 21'-6" is,-10" 17-2" (') IT-4" (') UNINHABITABLE ATTIC WITH LIMITED STORAGE DL=10PSF, LL=20PSF, L16=240 I 2X6 13'-1I' 12'-O" 11'-0" 9'-10" I 2X8 1T-7" 15'-3" 13'-11" 12'-6" I 2X10 20'-11" 16'-1" 16'-6" 14'-9" 2X12 24'-8" 21'-4" 19'-3" IT-5" CEILING JOISTS I UNINHABITABLE ATTIC WITHOUT STORAGE DL=5PSF, LL=IOPSF, L/6=240 I 2X6 18'-8" 16'-11- 15'-7" 13'-1" I 2X8 24'-7" 21'-7" 19'-8" IT-7" I 2X10 26-0" 25'-7" 23'-5" 20'-I1" I 2X12 26-0" 2641 26'4- 24'-8" NOTES: (1) TYPICAL RAFTER SPACING FOR TILE ROOF IS LIMITED TO 16" O C. MAX 304. FRAMING PENETRATIONS 304.1. NOTCHING OF STUDS SHALL NOT OCCUR IN THE MIDDLE 1/3 OF THE STUD HEIGHT. MAXIMUM STUD NOTCHING AND BORING SHALL BE AS FOLLOWS: EXTERIOR OR EXTERIOR OR BEARING WALL NON -BEARING WALL BEARING WALL NON -BEARING WALL / - (25% WIDTH MAX) (40 /o WIDTH MAX) (40% WIDTH MAX) {60 /o WIDTH MAX) P. �1� 1 7/16" �� 2 1/8"I t . . � 7/8 1 7/ 16 0� 6 y In 4 ✓ O 'p, O � �� N O %lp 1p -�- -�- o 00 % 1/2" 1/2' 1/2" 1/2" J y I � � �� „ "' 2 3/16 3 5/16 d 1 3/8" 2 3/16" X �✓/ �f 1(� N _ _ __�,__ --A--- 304.2. MAXIMUM ALLOWED 2X SAWN LUMBER RAFTERS, JOISTS AND BEAMS NOTCHING AND DRILLING SHALL BE AS FOLLOWS: X �_ - � W D/ MAX o LD om 2 U I4 11 4. T\ / __l\ 1% 0 0 1� ux � A "'. N'. INII, `­_� - -71 X z X a NOTCHING NOT a o U3 u / PERMITTED o L/3 / L , . .4 ' . 304.3. NOTCHING AND BORING OF ENGINEERED WOOD PRODUCTS IS PROHIBITED EXCEPT WHERE PERMITTED BY THE MANUFACTURER'S INSTALLATION GUIDE OR WITH PRIOR WRITTEN AUTHORIZATION FROM THE EOR. WEB HOLES IN PREFABRICATED I -JOISTS ARE PERMITTED ONLY WHERE SIZED, LOCATED, AND REINFORCED PER THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS, (SEE NOTES 104.4 AND 104.4.1). 305. ROOF FRAMING 305.1. ROOF AND ATTIC VENTILATION SHALL BE AS REQ'D BY OTHERS. REF TO IRC R806.5 FOR UNVENTED ATTIC AND ENCLOSED RAFTER ASSEMBLY REQUIREMENTS. 305.2. DIMENSIONS ON THE ROOF PLAN SHALL BE INTERPRETED AS FOLLOWS: 305.2.1. RAFTER, HIP, VALLEY, AND RIDGE LENGTHS (WHERE INDICATED) REPRESENT THE ACTUAL SLOPED MEMBER LENGTHS, ROUNDED UP TO THE NEAREST FOOT. 305.2.2. ALL OTHER DIMENSIONS REPRESENT HORIZONTAL PROJECTION LENGTHS UNLESS NOTED OTHERWISE. 305.2.3. RAFTER LENGTH FOR SPAN CHARTS SHALL BE MEASURED ALONG THE HORIZONTAL PROJECTION. 305.3. ROOF RAFTERS SHALL NOT BE SPACED FURTHER APART THAN 24" O.C. 305.4. TYPICAL RAFTER SIZE SHALL BE AS FOLLOWS: 305.4.1. ASPHALT SHINGLE OR METAL ROOF COVERING: 2X6@24"O.C. 305.4.2. TILE COVERING: 2X8 16 O.C. 305.4.3. THE ROOF FRAMING PLAN SHALL INDICATE THE ROOF COVERING MATERIAL FOR WHICH IT WAS DESIGNED. SUBSTITUTION TO A HEAVIER ROOF COVERING MATERIAL IS NOT PERMITTED WITHOUT PRIOR STRUCTURAL REVIEW AND WRITTEN APPROVAL FROM THE EOR. THE CONTRACTOR SHALL REVIEW THE DESIGN ASSEMBLY WEIGHTS OF NOTE 116.4 PRIOR TO COMMENCING CONSTRUCTION AND SHALL NOTIFY THE FOR IF ANY INTENDED MATERIAL EXCEEDS THOSE LIMITS. (SEE NOTE 116.7). 305.5. THE ENDS OF RAFTERS SHALL HAVE NOT LESS THAN 1-1/2" OF BEARING ON WOOD. 305.6. HIPS, VALLEYS, AND RIDGES SHALL BE 2-INCH NOMINAL THICKNESS MINIMUM AND SIZED TO PROVIDE FULL END -CUT BEARING FOR SUPPORTED RAFTERS. MINIMUM SIZES SHALL BE AS FOLLOWS, UNO PER PLAN: .1. ROOF PITH 12 T 11 12 - ONE DIMENSIONAL IZE LAR ER THAN ADJACENT RAFTER . 305 6 00 C 3/ 0 1 0S GS 305.6.2. ROOF PITCH 11 12 TO 16 12 - TWO DIMENSIONAL SIZES LARGER. 305.6.3. ROOF PITCH GREATER THAN 16/12 - THREE DIMENSIONAL SIZES LARGER. 305.6.4. ROOF PITCHES 3/12 AND OR LESS - HIPS, VALLEYS, AND RIDGES SHALL BE DESIGNED AS BEAMS. 305.7. ROOF RAFTERS SHALL BE NAILED TO THE TOP PLATE PER THE TYPICAL NAILING SCHEDULE (NOTE 302.8) AND SHALL BE CONNECTED TO THE TOP PLATE WITH AN H2.5 HURRICANE TIE AT EACH RAFTER, UNO. WHERE A VARIABLE PITCH CONNECTOR (VPA2 OR EQUIVALENT) IS USED AT THE RAFTER SEAT FOR OVERHANGS EXCEEDING 2'-0", THE H2.5 MAY BE OMITTED AT THAT LOCATION. HURRICANE TIE REQUIREMENTS SHALL COMPLY WITH NOTE 111. 305.8. PROVIDE PURLINS SAME SIZE AS RAFTERS THEY ARE SUPPORTING AND BRACE AT NOT MORE THAN 4'-0" O.C. TO WALL OR BEAM BELOW. PURLIN BRACE SLOPE SHALL NOT BE LESS THAN 450 FROM HORIZONTAL. PURLIN LINE SHALL BE CONNECTED TO ROOF RAFTERS AS FOLLOWS: ROOF RAFTERS (4) 3"X0.131" FACE NAILS TO RAFTER. WHERE FACE NAILS ARE ROOF SHEATHING OMITTED PROVIDE H2.5 TIE @ 48" O.C. FROM RAFTER TO BRACE PURLIN TIGHT AGAINST ROOF FRAMING. SIZE TO MATCH • ROOF RAFTERS W/ (4) 3"X0.131" NAILS EA BRACE STRONGBACK TIGHT AGAINST PURLIN o MA BRACE PER ROOF BRACE 0.PC-SCHEDULE 305.9. ROOF BRACES SHALL HAVE FULL BEARING ON TOP PLATE AND SHALL BE LOCATED WITHIN 4" FROM A STUD BELOW. CONNECT TO TOP PLATE PER TYPICAL NAILING SCHEDULE (NOTE 302.8). 305.9.1. WHERE MULTIPLE BRACES LAND AT THE SAME WALL LOCATION, PROVIDE A STUD UNDER EACH BRACE. 305.9.2. WHERE A SINGLE BRACE IS SHOWN AT RIDGE, VALLEY, OR HIP INTERSECTIONS, PROVIDE MINIMUM 1-1/2" BEARING FOR EACH SUPPORTED MEMBER - OR PROVIDE INDIVIDUAL BRACES WITHIN 12" OF THE INTERSECTION. 305.9.3. BRACE FRAMING SHALL BE SIZED PER ROOF BRACE SCHEDULE BELOW ACCORDING TO THE BRACE HEIGHT AT THE POINT OF SUPPORT ROOF BRACE SCHEDULE HEIGHT ASSEMBLY BRACE SECTION LESS THAN 8 FT 2X4 BRACE W/ 2X4 STRONGBACK 0.148"X3" @ 6" O.C. A I 8-1S FT 2X6 BRACE W/ 2X6 STRONGBACK 15-20 FT 2X8 BRACE W/ 2X8 STRONGBACK TYPICAL ROOF � STRONGBACK BRACE PER PLAN I 20-25 FT (2) 2X6 BRACE W/ 2X8 STRONGBACK BRACE 305.10. RAFTERS SHALL BE FRAMED NOT MORE THAN 1 1/2-INCHES OFFSET FROM EACH OTHER TO A RIDGE BOARD, OR DIRECTLY OPPOSITE FROM EACH OTHER WITH A COLLAR TIE, OR RIDGE STRAP. 305.11. RIDGE STRAPS OR COLLAR TIES SHALL BE INSTALLED IN THE UPPER 1/3 HEIGHT OF THE RAFTER AND SHALL NOT BE SPACED MORE THAN 4'-0" O.C. 305.11.1. COLLAR TIES SHALL BE NOT LESS THAN 1X4 NOMINAL AND INSTALLED AS FOLLOWS: RIDGE PLATE OR BEAM ROOF RAFTERS COLLAR TIE @ 48" O.C. MAX IN THE UPPER 1/3 OF RAFTER LENGTH OR WITHIN TOP 4'-0" WHICHEVER SMALLER COLLAR TIE TO RAFTER CONNECTION PER NAILING SCHEDULE 305.11.2. RIDGE STRAP SHALL BE NOT LESS THAN 1 1/4" X 20 GAUGE (CS20 BY SIMPSON STRONG TIE OR BETTER) AND SHALL BE NAILED TO THE TOP EDGE OF EACH RAFTER WITH NOT FEWER THAN (3) 10D COMMON (3"X0.148") NAILS WITH THE CLOSEST NAIL NOT CLOSER THAN 3" FROM THE END OF THE RAFTER. RIDGE BEAM RIDGE STRAP ROOF RAFTER 305.12. AT EXTERIOR WALLS, BIRDSMOUTH CUTS IN RAFTERS SHALL MAINTAIN: 305.12.1. MINIMUM 1 1/2" BEARING LENGTH OVER THE TOP PLATE 305.12.2. MINIMUM 3 1/2" RAFTER DEPTH AT THE SEAT FOR RAFTER OVERHANG 305.12.3. MINIMUM 5" HEEL HEIGHT AT EXTERIOR FACE OF WALL FRAMING 305.12.4. MAXIMUM NOTCH NOT MORE THAN 1/4 OF THE RAFTER DEPTH AT THE BEARING LOCATION 305.12.5. RAFTER OVERHANGS USING A BIRDSMOUTH CUT SHALL NOT EXCEED 2 -011 . FOR OVERHANGS EXCEEDING 2'-0", PROVIDE A VARIABLE PITCH CONNECTOR (SIMPSON VPA2 OR EQUAL) AT THE RAFTER SEAT. WHERE A VPA CONNECTOR IS USED, INSTALLATION OF AN H2.5 HURRICANE TIE MAY BE OMITTED. �'-0" MAX CANTILEVER CANTILEVER > 2'-0" (5'-0" MAX) � NO RAFTER NOTCHES ALLOWE z_y w (� in = = O ✓ �s f RAFTER, TYP VPA2 VARIABLE RAFTER, TYP ��� PITCH CONNECTOR -�- 305.13. WHERE RAFTERS ARE OVERCUT BEYOND MINIMUM REQUIRED RAFTER DEPTH AT THE BIRDSMOUTH, EACH RAFTER SHALL BE REPAIRED AS FOLLOWS: 305.13.1. AT VAULTED CEILING FRAMING: Y Q P /-\ A� . � RAFTERS PER PLAN - : � • - 3/4" PLYWOOD EACH SIDE OF RAFTER, SNUG TO T/PLATE M (3) ROWS OF 0.131"X3" NAILS @ 4" O.C. EA SIDE 305.13.2. AT FLAT CEILING FRAMING W/ LAPPED CEILING JOISTS OR BLOCKING: RAFTERS PER PLAN CEILING JOISTS PER PLAN DOD ONE SIDE OF RAFTER. SIZE AND NAILING D VAULTED OPTION (ONE SIDE ONLY) kJ j RVVVO OF 0.131"X3" NAILS @ 4" O.C. JOIST TO RAFTER 305.14. RAFTER SPLICES SHALL OCCUR DIRECTLY OVER SUPPORTS. PROVIDE A 4'-0" LONG SPLICE OF MATCHING MEMBER SIZE, CENTERED OVER THE SPLICE, SECURED WITH A MINIMUM OF TWELVE (12) 3" X 0.148" NAILS ON EACH SIDE OF THE SPLICE. ALTERNATIVELY LAP 24" OVER SUPPORT AND BE FACE NAILED W/ (12) 0.148" X 3" FACE NAILS. 305.15. HIP, VALLEY, AND RIDGE SPLICES SHALL OCCUR DIRECTLY OVER SUPPORTS AND BE SPLICED WITH (2) 4'4' LONG MATCHING MEMBERS CENTERED ON SPLICE, ONE EACH SIDE, FASTENED WITH (12) 0.148"X3" NAILS EACH SIDE OF SPLICE, EA FACE, AS FOLLOWS: FRAMING BUTTED UP AGAINST EACH OTHER HIP OR VALLEY BEING SPLICED (SIM AT RIDGE) 2-`J 4'-0" LONG SPLICE. NEAR SIDE AND FAR SIDE (12) 0.148"X3" EA SIDE OF SPLICE BRACE TIGHT AGAINST FRAMING BRACE OR PURLIN, AS REQ'D. SIZE PER ROOF BRACE SCHEDULE 305.16. RAFTERS SIZE 2X10 AND GREATER SHALL HAVE LATERAL BLOCKING AT BEARING POINTS AND @ 8'-0" O.C. ALONG THE LENGTH TO PREVENT ROTATION. 305.17. GABLE END WALLS SHALL HAVE SLOPED DOUBLE 2X TOP PLATES AT THE TOP OF WALL MATCHING THE SLOPE OF THE ROOF, CONSTRUCTED SIMILARLY TO STANDARD WALL FRAMING DOUBLE TOP PLATES. GABLE ROOF OVERHANGS UP TO 9" BEYOND THE WALL MAY BE FRAMED USING EXTENDED ROOF SHEATHING OVER LOOKOUT BLOCK. FOR OVERHANGS GREATER THAN 9", THE OVERHANG SHALL BE SUPPORTED BY CANTILEVERED OUTRIGGER EXTENDING BACK INTO THE ROOF STRUCTURE. OVERHAN GS LONGER THAN 2'-0" ARE NOT COVERED BY THESE STANDARD NOTES AND SHALL BE SPECIALLY DETAILED: ROOF SHEATHING CONTINUOUS F 2X OUTRIGGER @24" O.C. OVER WALL TO END OF CANTILEVER SHALL MATCH RAFTER SIZET/PROOFjjj �T/ROOF PEY R ARCH N PEE ARCH 1 A + N L IVYVI '- " MAX j 0'-9" 2 0 M MAX CANTILEVER J - ; ti 305.18. ATTIC WALL FRAMING SHALL MEET STUD SIZE AND SPACING REQUIREMENTS PER THE EXTERIOR WALL STUD SCHEDULE (NOTE 309.9.1). A DOUBLE TOP PLATE SHALL BE PROVIDED AT THE TOP OF ATTIC WALLS. 305.19. ROOF AREAS INDICATED AS "OVERFRAMED" SHALL HAVE CONTINUOUS SHEATHING AT THE OVERFRAMED RAFTERS IN ADDITION TO ROOF SHEATHING ABOVE. AT RAFTER BEARING, A FLAT NAILER SHALL BE PROVIDED EQUAL IN SIZE TO THE LENGTH OF THE SLOPE -CUT RAFTER END. MULTIPLE 2x FLAT NAILERS ARE ACCEPTABLE. OVERFRAMING SHALL BE FRAMED AS FOLLOWS: RIDGE BOARD, TYP RAFTER TO PLATE CONNECTION PER ROOF SHEATHING, TYP TYPICAL NAILING SCHEDULE. H2.5A 000 �� NOT REQUIRED - RAFTERS AT OVERFRAMING PER PLAN (3) 0.131"X3" NAILS AT EVERY RAFTER INTERSECTION , . ,FLAT 2X NAILER PLATE WITH COLLAR TIE, TYP EDGE RIPPED TO SLOPE OF ROOF OVERFRAMING PANEL EDGE NAILING �- - _L ]_ _L ROOF FRAMING PER PLAN ROOF SHEATHING BELOW OVERFRAMING. PROVIDE VENTILATION HOLES AS REQUIRED BY OTHERS. IF ROOF SHEATHING IS OMITTED, FULL HEIGHT BLOCKING SHALL BE PROVIDED BETWEEN ROOF FRAMING @ 4'-0" O.C. THROUGHOUT THE UNSHEATHED AREA 305.20. ROOF SHEATHING SHALL BE PER NOTE 303.4. APPLY WITH THE LONG DIMENSION (STRENGTH AXIS) ACROSS SUPPORTS, CONTINUOUS OVER TWO OR MORE SPANS. PANEL JOINTS IN THE SHORT DIRECTION SHALL BE STAGGERED. NAILING PER NAILING SCHEDULE (NOTE 302.8), UNO. PROVIDE 1/8" GAP BETWEEN PANELS FOR EXPANSION. (SEE NOTES 108.4-108.6). HATCHED AREAS REPRESENT AREAS THAT ARE WITHIN 4'-0" FROM EVES, RIDGES, HIPS AND VALLEY THAT REQUIRE TIGHTER NAIL SPACING. REF 302.8 ADDITIONAL REQUIREMENTS APPLY AT SHEATHING ATTACHMENT AT GABLE END FRAMING 305.21. PRE-ENGINEERED WOOD OPEN WEB ROOF TRUSSES SHALL BE DESIGNED BY THE TRUSS MANUFACTURER PER NOTES 106.1 THROUGH 106.9. TRUSS DESIGN DRAWINGS SHALL BE SUBMITTED TO THE FOR FOR REVIEW AND APPROVAL PRIOR TO FABRICATION PER NOTE 121.3.1. 306. CEILING FRAMING 306.1. MINIMUM CEILING JOISTS SHALL BE 2X6 @ 24" O.C., UNO PER PLAN. 306.2. THE ENDS OF CEILING JOISTS SHALL HAVE NOT LESS THAN 1-1/2" OF BEARING ON WOOD. 306.3. WHERE A HANGER IS INDICATED PER PLAN, IT SHALL BE SELECTED FROM THE APPLICABLE HANGER SCHEDULE (NOTES 303.14.3 AND 303.14.4) UNLESS OTHERWISE SPECIFIED PER PLAN. ALL CONNECTOR REQUIREMENTS ARE PER NOTES 111.1 THROUGH 111.9. 306.4. CEILING JOISTS 2x10 AND LARGER SHALL HAVE EITHER A lx4 CONTINUOUS WOOD STRIP NAILED ACROSS THE TOP OF JOISTS OR SOLID BLOCKING INSTALLED AT 8'-0" O.C. MAXIMUM, AND SHALL HAVE SOLID BLOCKING AT ALL BEARING LOCATIONS, TO PREVENT ROTATION. 306.5. ENDS OF CEILING JOISTS SHALL BE LAPPED NOT LESS THAN 3" OR BUTTED OVER BEARING PARTITIONS OR BEAMS AND TOE -NAILED TO THE BEARING MEMBER. 306.6. AT EXTERIOR WALLS WHERE CEILING JOISTS REQUIRE A TAPERED END CUT TO ACCOMMODATE ROOF SLOPE, THE TAPERED END SHALL MAINTAIN A MINIMUM 5" HEEL HEIGHT AND SHALL BE FRAMED AS FOLLOWS: MAX DEPTH OF TAPER CUT, D/4, MEASURED AT INSIDE FACE OF SUPPORT CEILING JOIST, TYP I . D/4 � / C % z - _ � DEPTH, D T/ PL L Lu w PE� Ln _ _ -�1_ JOIST DEPTH AT TAPER CUT 306.7. ALL EXTERIOR WALLS SHALL BE BRACED AT TOP BY ROOF, CEILING OR FLOOR FRAMING. 306.7.1. WHERE AT LEAST ONE SIDE OF THE WALL HAS CEILING OR FLOOR FRAMING PERPENDICULAR TO THE TOP PLATE, SEE NAILING SCHEDULE (NOTE 302.8) FOR THE REQUIRED JOIST -TO -WALL CONNECTION. 306.7.2. WHERE FRAMING IS PARALLEL TO THE TOP PLATE, PERPENDICULAR BLOCKING SHALL BE PROVIDED AT 2'-0" O.C. MAXIMUM TO BRACE THE TOP OF WALL: AT HIP ROOF: RAFTERS PER PLAN BLOCKING TO MATCH CEILING JOIST SIZE (3) 0.131"73" FACE NAILS CEILING JOISTS PER PLAN BLOCKING TO RAFTERS _ (3) 0.131"X3" END NAILS _ TYP CEILING JOIST TO TOP PLATE CONNECTION v/� EI PER NAILING SCHEDULE f �4 vv -.- a * I ALIAKSEI wA EVICH .............................. ',, s 130521 f 4 • �Oc �•'•7/OENSE�•'�r�,�� �,,SS%'••........• GX� N 1 O E ONAL AL w 0 Z O� (9 _ D Z 0 W 3 0 tan X WLW Z W Z_ Z2 00W J M m 2: � o C) O'� ko U � n U x Z 2: ln� fY Ld Lu W u- z Z , W a Z W X � C) I- l --i J NI _ ,--I U X O w m Ln Q L 0- m ,--1 00 fV i Ln [V LD REVISIONS 0 DATE BY PROJECT NAME 101 CROSS CREEK GARAGE ADDITION PROJECT ADDRESS 101 CROSS CREEK DR GRAPEVINE, TX PROJECT NUMBER S26129 CHECKED BY - AP SHEET DATE - 05/04/2026 SCALE 24X36 SHEET:1/2"=1'-0" 1___�7� JOIST AT LOW SLOPED R D G , EXCEEDS JOIST SPA G, PROVIDE SECOND(Il1` C F GRAPEVINE AT BLOCKING ATTA ENTTHIS PAGE RELEASED FOR CONSTRUCTION AT GABLE END: RELEASE DOES NO T AUTHORIZ&4NY WOF;K IN CONFLICT WITH THE BUILDING CODE OR ZONING 1--7 ORDINANCE Q GABLE END WALL STU t T/ PL 1 �- PE� ARCH -- SIM TO ABOVE. BLOC G SPACING30ROVED PLANS 70 BE MPT ON -'HE JOB _t_ MATCH GABLE END STUD SPACING SITE AT A _L TIM16 306.8. AT RAISED (TRAY OR BOX) CEILING LOCATIONS INDICATED ON ARCHITECTURAL PLANS, WHERE THE z RAISED CEILING FRAMING AND ROOF FRAMING OVERLAP, FRAMING SHALL BE AS FOLLOWS: 07/07/2026 9:21 Z� AM 306.8.1. CEILING JOISTS: _ RAFTERS PER PLAN (6) 0.131" X 3" FACE BY: KELLY TAF f TSmnE: 1-%3971� NAILS JOIST TO RAFTERC) (2) ROWS OF 0.131" X 3" CEILING JOISTS PER PLAN � z � @ 4" O.C. FACE NAILS KNEE BRACE TO MATCH RAFTER RAFTER TO KNE RACE BUILDING IN 'TION ION: �..• RELEASE DOES NOT LY TO C�RSTRUCI�..I: �I: SIZE. CUT SNUG TO CEILING \ _ JOISTS AND TOP PLATE �� �� --- - EASEMENTS OF. Q EILIC RI -OF -WA'( to WALL BELOW Lu = ALL CHANGES MUST BE ROVE). V) rCEILING JOISTS PER PLAN f T/PL @ HIGH CEILING PER ARCH r G N 301. GENERAL FRAMING NOTES, TYP METAL SUPPORTS, OR LESS THAN 3" AT CONCRETE OR MASONRY SUPPORTS. FOR ADDITIONAL BEAM AND JOIST BEARING, FRAMING NOTATION, LOAD PATH, CONNECTOR, AND MULTI -PLY BEAM REQUIREMENTS, DETAILS AND SCHEDULES CONTINUED SEE NOTES 303.6 THROUGH 303.13. 307.4. FULL -DEPTH BLOCKING, RIM BOARD, OR A PERPENDICULAR BEAM SHALL BE PROVIDED AT ENDS OF 306.8.2. MULTI -PLY SAWN LUMBER 2X CEILING BEAM OVERLAP: FLOOR JOISTS AND AT POINTS OF VERTICAL SUPPORT FOR MULTI -SPAN JOISTS TO PREVENT ROTATION RAFTERS PER PLAN. MIN (2) EA SIDE OF (6) 0.131" X 3" FACE NAILS AND MAINTAIN LATERAL STABILITY. BEAM. NAIL RAFTERS TO EACH OTHER W/ FIRST RAFTER TO BEAM, BOTH 307.5. FULL -DEPTH BLOCKING PROVIDED AT INTERMEDIATE SPAN LOCATIONS SHALL MATCH THE DEPTH OF 0.131"X3" FACE NAILS @ 4" O.C. STAGGERED SIDES OF BEAM ADJACENT FLOOR FRAMING, BE INSTALLED PERPENDICULAR TO THE JOISTS, AND BE FASTENED TO EACH ADJACENT JOIST WITH A MINIMUM OF 2 0.131„ X 3„ NAILS. BLOCKING SHALL BE INSTALLED AS BEAM PER PLAN (2) ROWS OF 0.131" X 3" @ 4' ( ) O.C. FACE NAILS FIRST RAFTER FOLLOWS: KNEE BRACE UNDER BEAM TO MATCH O. KNEE BRACE 307.5.1. 2X FLOOR FRAMING: TO RAFTER SIZE AND OVERALL BEAM WIDTH \ ' • / FLOOR FRAMING PER PLAN STUDS BELOW TO MATCH OVERALL WIDTH ` FULL HEIGHT BLOCKING OF BEAM -RAFTER ASSEMBLY ABOVE 4WL � ISO RAFTERS PER PLAN -- (6) 0.131" X 3" FACE NAILS FIRST RAFTER TO BEAM, BOTH BEAM PER PLAN SIDES OF BEAM (2) ROWS OF 0.131" X 3" @ 3" O.C. FACE KNEE BRACE TO MATCH RAFTER NAILS FIRST RAFTER TO KNEE BRACE �SIZE. CUT SNUG TO CEILING JOISTS AND TOP PLATE ELEVATION 306.9. AT RAISED (TRAY OR BOX) CEILING WITHIN INTERIOR SPACES, CEILING JOISTS AND BEAMS SHALL CONTINUE TO T/WALL AND TRAY SHALL BE FRAMED AS FOLLOWS: 306.9.1. W/DOUBLE TOP PLATE AT WALLS W/ LOW CEILING ON THE OPPOSITE SIDE OF THE WALL: CEILING JOISTS OR BEAM PER \• PLAN. CONTINUOUS TO WALL �- TOP PLATE AT CEILING JOISTS CEILING JOISTS AT LOW CEILING (3) 0.131 X3, FACE NAILS AT L� �r KNEE BRACE TOP AND BOT TOP PLATE AT T/ WALL. 306.9.2. W/ CONTINUOUS STUDS TO T/ TRAY CEILING: CEILING JOISTS OR BEAM PER \• -- PLAN. CONTINUOUS TO WALL \ TOP PLATE AT CEILING JOISTS \ _ (3) 0.131"X3" FACE NAILS TOP 2X6 NAILER AT WALL W 3 0,131" X 3" NAILS EA STUD (3) 0.131"X3" TOE NAILS AT KNEE BRACE TO NAILER 306.9.3. A DOUBLE TOP PLATE SHALL NOT BE PROVIDED AT AN INTERMEDIATE HEIGHT IN THE WALL UNLESS THE PLATE IS BRACED BY A CEILING DIAPHRAGM ON AT LEAST ONE SIDE OF THE WALL. FRAMING FOR A TRAY OR BOX CEILING SHALL NOT BE CONSIDERED AS BRACING FOR AN INTERMEDIATE TOP PLATE UNLESS SPECIFICALLY DETAILED AS SUCH ON THE STRUCTURAL DRAWINGS. 306.10. WHERE A CEILING BEAM DEPTH IS AT LEAST 1.5x THE DEPTH OF ADJACENT CEILING JOISTS, OR EXCEEDS 12" IN DEPTH, LATERAL BRACING SHALL BE PROVIDED AT THE TOP OF THE BEAM TO PREVENT ROTATION. BRACES SHALL BE AT MAXIMUM 8'-0" O.C. ON OPPOSITE SIDES OF THE BEAM WHERE SPACE PERMITS: (3) 3"X0.131" TOE NAILS 2X4 KNEE BRACE @ 8'-0" O.C. 2X STRONG BACK AT AT PERPENDICULAR FRAMING 2 PARALLEL FRAMING (3) 3"X0.131" FACE NAILS 1 I PEYPL T/ R ARCH CEILING JOIST HANGER, TYP BEAM 306.11, AT INTERIOR WALLS WHERE CEILING HEIGHT IS NOT EQUAL ON BOTH SIDES OF THE WALL, A FRAMING BRACE SHALL BE PROVIDED @ 48" O.C. AS FOLLOWS: (4) 0.131" X 3" FACE NAILS TOP AND BOT OF BRACE 2X4 KNEE BRACE @ 4'-0" O.C. 1 1� j CRIPPLE STUDS SISTERED TO LOW CEILING JOISTS TO MATCH T/PL @ LOW CEILING ! SIZE OF WALL BELOW PER ARCH (4) 0.131" X 3" FACE NAILS CEILING JOISTS PER PLAN AT OVERLAP 306.12. AT EXTERIOR WALLS WHERE THE TOP PLATE AT ROOF IS HIGHER THAN THE TOP PLATE FOR INTERIOR CEILING HEIGHT, A KNEE BRACE SHALL BE PROVIDED AT MAXIMUM 4'4" O.C., SLOPED APPROXIMATELY 1:1 DOWN TO CEILING FRAMING: 306.12.1. AT PERPENDICULAR CEILING FRAMING: ROOF FRAMING PER PLAN (4) 0.131"X3" FACE NAILS AT KICKER TOP 2X4 KICKER @ 4'-0" O.C. T/ PL (4) 0.131"X3" TOE NAILS BOT, (2) EA SIDE PER CONTINUOUS 2X6 NAILER WITH 2X6 STRONGBACK ; 0.131"X3" @ 6" O.C. NAILER TO STRONGBACK, TYP 6" MAX T/ PL PER (2) 0.131"X3" FACE NAILS STRONGBACK TO EA JOIST CEILING FRAMING PER PLAN CRIPPLE STUDS SISTERED TO CEILING JOISTS (4) 0.131"X3" FACE NAILS JOIST TO CRIPPLE STUD 306.12.2. AT PARALLEL CEILING FRAMING: ROOF FRAMING PER PLAN (4) 0.131"X3" FACE NAILS NAILER TO BLOCKING 2X4 KICKER @ 4' 0" O.C. T� (4) 0.131"X3" FACE NAILS AT KICKER TOP AND BOT PERTR H 4'-0" 2X6 NAILER WITH 2X6 STRONGBACK TO MATCH KICKER SPACING (2) 0.131"X3" EVERY CEILING JOIST T/ PLC� PERPERARCHC CEILING FRAMING PER PLAN BLOCKING 307. FLOOR FRAMING 307.1. FLOOR FRAMING SHALL BE CONTINUOUS BETWEEN POINTS OF VERTICAL SUPPORT AS INDICATED ON PLAN. SPLICING IS NOT ALLOWED WHERE MEMBERS ARE NOT DIRECTLY SUPPORTED BELOW. CANTILEVERED FRAMING SHALL NOT BE SPLICED. MEMBERS DESIGNATED "CONT," "CONTINUOUS," "2-SPAN," "3-SPAN," OR SIMILAR SHALL BE INSTALLED CONTINUOUS OVER MULTIPLE SUPPORTS WITHOUT SPLICES. 307.2. FLOOR JOISTS SHALL HAVE FULL BEARING ON TOP PLATES. JOISTS FRAMING FROM OPPOSITE SIDES OVER A BEARING SUPPORT SHALL LAP NOT LESS THAN 3" AND BE NAILED TO TOP PLATE PER TYPICAL NAILING SCHEDULE (NOTE 302.8). 307.3. FLOOR BEAMS SHALL HAVE FULL BEARING ON TOP PLATES, WHERE BEAMS OCCUR IN LINE ON OPPOSITE SIDES OF A WALL, EACH SHALL HAVE 1/2 PLATE WIDTH FOR BEARING, LINO PER PLAN. AT PERIMETER WALLS, FLOOR FRAMING SHALL HAVE FULL BEARING EXCLUDING RIM BOARD WHERE APPLICABLE. UNDER NO CIRCUMSTANCES SHALL FLOOR JOISTS, BEAMS, OR GIRDERS BEAR LESS THAN 1-1/2" AT WOOD OR 307.5.2. ENGINEERED WOOD I -JOISTS: (2) FACE NAILS FROM JOISTS INTO BLOCKING FLOOR FRAMING PER PLAN FULL HEIGHT BLOCKING 2X4 NAILER EA SIDE W/(2) FACE NAILS FROM JOISTS WEB INTO NAILER AND (2) FACE NAILS FROM BLOCKING WEB INTO NAILER. (NAILER NOT REQUIRED AT BEARING WALL BELOW) 307.6. FULL -DEPTH BLOCKING SHALL BE PROVIDED UNDER PERPENDICULAR LOAD -BEARING WALLS ABOVE AND OVER LOAD -BEARING WALLS BELOW TO ENSURE PROPER LOAD TRANSFER AND LATERAL STABILITY. REFER TO SHEAR WALL SCHEDULE (NOTE 409) FOR ADDITIONAL REQUIREMENTS AT SHEAR WALLS. CONNECTION PER TYPICAL NAILING SCHEDULE (OR PER SHEARWALL SCHEDULE IF SHEARWALL ABOVE) FULL HEIGHT BLOCKING FLOOR FRAMING�� PER ARCH PEER ARCH , CONNECTION PER TYPICAL FLOOR FRAMING NAILING SCHEDULE (OR PER FULL HEIGHT BLOCKING SHEARWALL SCHEDULE IF SHEARWALL BELOW) 307.7. TYPICAL FLOOR FRAMING DETAILS (WALLS ABOVE NOT SHOWN FOR CLARITY): 307.7.1. PARALLEL FRAMING AT EXTERIOR WALL: NAILING INTO RIM PER TYPICAL NAILING SCHEDULE RIM TO BLKG SIM TO RIM TO END OF JOISTS PER TYP NAILING SCHEDULE �T/ FLFR FLOOR SHEATHING PERARCHY RIM BOARD FLOOR FRAMING PARALLEL TO WALL BLOCKING @ 24" O.C. BLOCKING TO JOIST ATTACHMENT PER SECTION 72.2 BLOCKING TO TOP PLATE ATTACHMENT PER TYPICAL NAILING SCHEDULE TOE NAIL AT RIM PER TYPICAL NAILING SCHEDULE 307.7.2. PARALLEL FRAMING AT INTERIOR WALL (NON -BEARING, NON-SHEARWALL): T/ FLFR PER ARCH INTERIOR NON -LOAD BEARING WALLS SHALL BE-,,," BRACED AT TOP BY CEILING DIAPHRAGM VIA NAILER ATTACHMENT TO THE TOP OF THE WALL �< umo 307.7.3. PARALLEL FRAMING AT INTERIOR WALL (BEARING, AND/ OR SHEARWALL): NAILING INTO FRAMING BELOW PER TYPICAL NAILING SCHEDULE (OR SHEARWALL SCHEDULE AT SHEARWALLS) (3) 0.131"X3" SHEATHING TO BLOCKING T/FLFR,� FLOOR SHEATHING �r � PER AR CH JOIST OR LSL/LVL (REF SHEARWALL SCHEDULE) FLOOR FRAMING PARALLEL TO WALL BLOCKING @ 24" O.C. rs'• BLOCKING TO JOIST ATTACHMENT PER SECTION 72.2 BLOCKING TO TOP PLATE ATTACHMENT PER TYPICAL NAILING SCHEDULE CONNECTION PER TYPICAL NAILING SCHEDULE (OR SHEARWALL SCHEDULE AT SHEARWALLS) 307.7.4, PERPENDICULAR FRAMING AT INTERIOR AND EXTERIOR WALLS: NAILING INTO BLOCKING PER NAILING INTO RIM PER TYPICAL TYPICAL NAILING SCHEDULE NAILING SCHEDULE FULL HEIGHT BLOCKING FLOOR SHEATHING RIM BOARD FLOOR SHEATHING 1 T/ FLFR FLOOR FRAMING FLOOR FRAMING PER ARCH PERPENDICULAR TO WALL PERPENDICULAR TO WALL FLANGE NAIL AT ENGINEERED I -JOIST FRAMING TO TOP PLATE (OR TOE NAIL AT SOLID BLOCKING) ATTACHMENT PER TYPICAL PER TYPICAL NAILING SCHEDULE NAILING SCHEDULE FRAMING TO TOP PLATE ATTACHMENT TOE NAIL AT RIM PER PER TYPICAL NAILING SCHEDULE TYPICAL NAILING SCHEDULE INTERIOR EXTERIOR 307.8. FLOOR SHEATHING SHALL BE PER NOTE 303.4. APPLY WITH THE LONG DIMENSION (STRENGTH AXIS) ACROSS SUPPORTS, CONTINUOUS OVER TWO OR MORE SPANS. PANEL JOINTS IN THE SHORT DIRECTION SHALL BE STAGGERED, FLOOR SHEATHING SHALL BE GLUED AND NAILED. NAILING PER NAILING SCHEDULE (NOTE 302.8), UNO PER SHEAR WALL SCHEDULE (NOTE 409). ADHESIVES SHALL MEET APA SPECIFICATION AFG-01 OR ASTM D3498 AND BE APPLIED PER MANUFACTURER'S RECOMMENDATIONS. (SEE NOTES 108.4-108.8). 307.9. WHERE A HANGER IS INDICATED PER PLAN, IT SHALL BE SELECTED FROM THE APPLICABLE HANGER SCHEDULE (NOTES 303.14.3 AND 303.14.4) UNLESS OTHERWISE SPECIFIED PER PLAN. 307.10. PROVIDE WEB STIFFENERS AT ENGINEERED WOOD I -JOISTS WHERE INDICATED ON PLANS OR DETAILS, INSTALLED PER MANUFACTURER REQUIREMENTS. WEB STIFFENER AT TJI JOISTS SHALL BE AS FOLLOWS: GAP: 1/8" MIN, 2 3/4" MAX WEB STIFFENER SCHEDULE TJI SERIES WEB STIFFENER NAILS _ NAILS PER SCHEDULE. CLINCH AS REQ'D 210 3/4" X 2 5/16" (') (3) 0.131" X 21/2" WEB STIFFENER PER SCHEDULE, BOTH SIDES 2301,111 7/8" X 2 5/16" (') (3) 0.131" x z 1/2" 560 2X4 (`) (3) 0.162" X 3 1/2" _ TIGHT FIT TO BOTTOM FLANGE NOTES: �+ (1) P51 OR P52 SHEATHING, FACE GRAIN VERTICAL (2) #3 GRADE OR BETTER 307.11. PROVIDE VERTICAL CRUSH BLOCKING (V.C.B.) WITHIN FLOOR FRAMING WHERE POSTS OR BUNDLED STUDS ABOVE ALIGN WITH WALLS BELOW; BLOCKING SHALL MATCH OR EXCEED THE SIZE OF SUPPORTED MEMBERS AND EXTEND FULL FLOOR DEPTH, SNUG TOP AND BOTTOM: POST OR BUNDLED STUDS ABOVE T/FLR FRAMING VERTICAL CRUSH BLOCKING (VCB) PER ARCH WIDTH OF BLOCKING MATCH OR EXCEED WIDTH OF POST OR BUNDLED STUDS ABOVE ( T/ PL j PER ARCH POST OR BUNDLED STUDS BELOW 307.12. PRE-ENGINEERED WOOD OPEN WEB FLOOR TRUSSES SHALL BE DESIGNED BY THE TRUSS MANUFACTURER PER NOTES 106.1 THROUGH 106.9. TRUSS DESIGN DRAWINGS SHALL BE SUBMITTED TO THE FOR FOR REVIEW AND APPROVAL PRIOR TO FABRICATION PER NOTE 121.3.1. 308. DECKS 308.1. WOOD -FRAMED DECKS EXPOSED TO WEATHER SHALL BE CONSTRUCTED WITH DECAY -RESISTANT OR PRESERVATIVE -TREATED FRAMING PER NOTE 103.5. ALL FASTENERS AND CONNECTORS SHALL MEET THE CORROSION PROTECTION REQUIREMENTS OF NOTES 110.3 AND 111.3 FOR EXTERIOR AND TREATED WOOD APPLICATIONS. 308.2. THE WEATHER BARRIER AT EXTERIOR WALLS SHALL BE CONTINUOUS THROUGH DECK FRAMING. PROVIDE FLASHING AS REQUIRED. WATERPROOFING, FLASHING, AND SEALANTS ARE NOT INCLUDED IN THE STRUCTURAL SCOPE AND SHALL BE DESIGNED BY OTHERS. (SEE NOTE 126.1.) 308.3. RIM BOARD AT DECK CONNECTION SHALL BE A MINIMUM 1 1/2" THICK, LINO. 308.4. FOR TYPICAL LOADING CONDITIONS (10 PSF DL, 40 PSF LL), DECK LEDGER SHALL BE CONNECTED TO RIM BOARD PER THE DECK LEDGER CONNECTION SCHEDULE BELOW: LEDGER CONNECTION OPTIONAL 1/2" 1" MAX RIGID PER SCHEDULE GAP W/STACKED FOAM BOARD WASHERS FASTENERS SHALL BE VERTICALLY OFFSET BETWEEN ROWS DECK LEDGER CONNECTION SCHEDULE FOR IOPSF DL, 40 PSF LL... MAX DECK JOISTS SPAN MIN VERTICAL PER FASTENER 641. ` JJ l DISTANCEALLOWABLE FASTENER TYPE FROM MAXIMO.C.ISPACINIG OF FASTENERS TOP M LEDGER BETWEEN SHEAR LOAD UM ANDBOT"") ROWS (CBS) SDWS224000DB 14" 8" 6" 5" 6" 4" 265 SDWS2740055 13" 8" 6" 4" 6" 4" 235 SDWH1940ODB 13" 8" 5" 4" 6" 4" 225 SDWH2740OG 22" 13" 10" 7" 6" 4" 280 SDWH2740OSS 19" 11" 8" 6" 3" 11/2' 235 SDWH19400SS 14" 11" 6" 5" 3" 11/2 ' 177 SDS25312 13" 8" 5" 4" 4" 3" 165 MAXIMUM O.C. SPACING OF FASTENERS TOP AND BOT WITH 112" GAP (2)(3} SDWH1940ODB 13" I 8" I 5" I 4" 6" 4" 245 MAXIMUM O.C. SPACING OF FASTENERS TOP AND BOT WITH 1" RIGID FOAM BOARD (2'(3) SDWH274DOG lZ" I 7" I 5" I 4" 6" 4" I) NOT APPLICABLE FOR DECKS W/ CONC TOPPING OR HEAVY TILE SYSTEMS. 2) AT LEDGERS 10" TO 16" TALL ADD ANOTHER ROW OF FASTENERS IN THE MIDDLE OF LEDGER. 3) AT LEDGERS 16" TO 22" TALL ADD TWO ROWS OF FASTENERS IN THE MIDDLE SPACED AT 6" MAX O.C. VERTICALLY. 309, WALL FRAMING 309.1. STUDS SHALL BE CONTINUOUS BETWEEN THE SILL (SOLE, BOTTOM) PLATE AND THE TOP PLATE TO RESIST LOADS PERPENDICULAR TO THE WALL. CONNECTIONS PER NAILING SCHEDULE (NOTE 302.8). SUPPORTS SHALL BE FOUNDATION, FLOOR, CEILING, OR ROOF DIAPHRAGM, EXCEPTION: JACK AND CRIPPLE STUDS AT OPENINGS. 309.2. STUDS SHALL BE INSTALLED WITH THE WIDE FACE PERPENDICULAR TO THE WALL LINE, WITH SHEATHING AND DRYWALL ATTACHED TO THE NARROW FACE. 309.3. STUD WALLS SHALL BE CAPPED WITH A DOUBLE TOP PLATE HAVING A WIDTH AT LEAST EQUAL TO THE STUD WIDTH, PROVIDING OVERLAPPING AT CORNERS AND INTERSECTIONS WITH BEARING PARTITIONS. END JOINTS IN A CONTINUOUS TOP PLATE SHALL BE OFFSET AT LEAST 2'-0", LINO. TOP PLATE CONTINUITY, SPLICING, AND CONNECTION REQUIREMENTS SHALL BE AS FOLLOWS: 309.3.1. TYPICAL LAP SPLICE: LAP SPLICE (MIN 2'- PIQ") T/ PLIRCH T/PL TO T/PL NAILING PER TYPICAL NAILING SCHEDULE PLATE JOINT NAILING AT T/PL SPLICE PER TYPICAL NAILING SCHEDULE a I PLATE JOINT 309.3.2. TYPICAL CORNER JOINT: PERPENDICULAR WALL FRAMING LAPPED AND ATTACHED PER TYPICAL NAILING SCHEDULE ONE TOP PLATE SHALL BE CONTINUOUS THROUGH JOINT WALL FRAMING PER PLAN 309.3.3. WHERE A CONTINUOUS EXTERIOR WALL OR INTERIOR SHEAR WALL TRANSITIONS TO A DIFFERENT WALL THICKNESS AND A STANDARD TOP PLATE LAP SPLICE CANNOT BE ACHIEVED, PROVIDE A CS16XT-0" STRAP CENTERED OVER THE SPLICE AND FASTENED WITH (22) 0.131"X2 1/2" NAILS EACH SIDE OF SPLICE. PERPENDICULAR WALL FRAMING LAPPED AND ATTACHED PER TYPICAL NAILING SCHEDULE WALL FRAMING PER PLAN BOTH TOP PLATES ARE TERMINATED AT WALL THICKNESS TRANSITION CS16 X T-0" CENTERED ON SPLICE 309.3.4. TOP PLATES MAYBE OMITTED OVER A HEADER OR BEAM WHERE THE HEADER OR BEAM IS CONNECTED TO THE ADJACENT TOP PLATES ON EACH SIDE WITH A CS16 x Y-0" STRAP CENTERED AT THE JOINT AND FASTENED WITH (22) 0.131"X2 1/2" NAILS EACH SIDE OF JOINT, UNO: --WALL FRAMING PER PLAN -CS16 X T-0" CENTERED ON SPLICE ABEAM OR HEADER PER PLAN 309.3.5. A SINGLE TOP PLATE IS PERMITTED OVER A HEADER PROVIDED THAT: 309.3.5.1. THE TOP PLATE LAPS THE HEADER BY THE MINIMUM REQUIRED LAP DISTANCE AND IS NAILED TO THE HEADER PER THE TYPICAL NAILING SCHEDULE TOP PLATE LAP SPLICE. 309.3.5.2. THE TOP PLATE CONTINUING PAST THE HEADER SHALL LAP AND CONNECT TO THE ADJACENT DOUBLE TOP PLATE BY THE MINIMUM REQUIRED LAP DISTANCE AND NAILING PER THE TYPICAL NAILING SCHEDULE TOP PLATE LAP SPLICE. i-� CONTINUOUS TOP PLATE WITH LAP DISTANCE AND CONNECTION TO ADJACENT TOP PLATE AS REQUIRED FOR LAP SPLICE WALL FRAMING PER PLAN SINGLE TOP PLATE CONTINUOUS OVER THE BEAM AT TOP PLATE SPLICES OVER BEAMS, PROVIDE A MINIMUM T-0" LAP LENGTH EACH SIDE OF SPLICE AND FASTEN WITH (12) 0.131"X3" SHALL PER SIDE BEAM OR HEADER PER PLAN 309.3.6. WHERE PIPING OR DUCTWORK REQUIRES DRILLING OR NOTCHING OF THE TOP PLATE BY MORE THAN 50%, PROVIDE A GALVANIZED METAL TIE 16 GAx 1-1/2' WIDE FASTENED ACROSS THE NOTCH WITH MINIMUM (10) 0.148"x3-1/4" NAILS EACH SIDE (MSTC28 OR (2) CS16x2'-6" MINIMUM). MINIMUM 1-1/2" WIDTH OF TOP PLATE SHALL REMAIN AT NOTCH: PENETRATION REQUIRING MORE THAN 50 PERCENT NOTCH IN TOP PLATES TOP PLATES WALL FRAMING PER PLAN MSTC28 CENTERED ON SPLICE (ALT (2) CS16 X 2'4") 309.4. WOOD STUDS SHALL HAVE FULL BEARING ON A NOMINAL 2X SILL PLATE (OR 3X WHERE REQUIRED BY SHEAR WALL SCHEDULE (NOTE 409)) HAVING A WIDTH NOT LESS THAN THE STUD WIDTH, UNLESS NOTED OTHERWISE. 309.4.1. DOUBLE SILL PLATE IS REQUIRED AT PORTAL FRAMES. REF NOTE 412. 309.5. SILL PLATES SHALL BE ATTACHED TO WOOD FRAMING BELOW PER NAILING SCHEDULE (NOTE 302.8). SEE SHEAR WALL SCHEDULE (NOTE 409) FOR NAILING REQUIREMENTS AT SHEAR WALL LOCATIONS. 309.6. SILL PLATES SHALL BE ANCHORED TO CONCRETE PER THE SILL PLATE ANCHOR SCHEDULE BELOW, UNO. SEE SHEAR WALL SCHEDULE (NOTE 409) FOR ANCHOR REQUIREMENTS AT SHEAR WALL LOCATIONS: 309.6.1. FOR EXTERIOR WALLS 10'-0" IN HEIGHT OR LESS, AND FOR ALL INTERIOR WALLS; SILL PLATE ANCHOR SCHEDULE ('X3Xs) MAXIMUM O.C. SPACING OF FASTENERS MINIMUM EDGE FASTENER TYPE MIN CONC THICKNESS DISTANCE EXTERIOR WALLS INTERIOR WALLS 1/2' 0 CAST IN PLACE A.B (2) 6'-0" 6-0" 1'-0" 2" PDPAWL-287MG 11-10" 4'-0" 4" 2" 1/2"X6" TITEN HD (4) 6 4' 6-0" 8" 2" MASH 6'-0" 8" - 1) AT NON SHEARWALLS. FOR SHEARWALL ANCHORAGE REFER TO SHEARWALL SCHEDULE. 2) 1/2" 0 ANCHOR BOLTS SHALL HAVE MIN 7" CONCRETE EMBEDMENT. SHALL BE SET IN PLACE BEFORE POUR OR PLACED WHEN CONCRETE IS STILL PLASTIC. CONCRETE SHALL BE VIBRATED AROUND ANCHOR BOLTS TO ENSURE CONTACT BETWEEN ANCHORS AND CONCRETE. PROVIDE STANDARD NUT AND WASHER. 3) 10'-0" MAX EXTERIOR WALL HEIGHT. FOR TALLER WALLS, REFER TO SILL PLATE ANCHORAGE TO CONCRETE AT TALL WALLS SCHEDULE. 4) MECHANICALLY GALVANIZED OR STAINLESS STEEL. 5) PROVIDE MINIMUM (2) ANCHORS PER PLATE, WITH ONE ANCHOR LOCATED WITHIN 12" BUT NOT LESS THAN 4" FROM EACH END OF THE PLATE SECTION. 309.6.2. FOR EXTERIOR WALLS GREATER THAN 10'-0" AND UP TO 24'-0" 1N HEIGHT SILL PLATE ANCHOR SCHEDULE AT TALL WALL5('X2) EXTERIOR WALL HEIGHT f3j FASTENER TYPE 12'-0" I 14'-0" I 16"4" I 18'4" I 20'4' I 22'-0" I 24'-W MAXIMUM O.C. SPACING OF FASTENERS 1/2" 0 CAST 1N PLACE A.B. 5'-0" 4'-D" T-6" T-3" 3'4' 2'.9" 2'4" 1/2"X6" TITEN HD (4) 5'-0" 4'-0" T-6" 3'-3" T-O" 2'.9" 2'-6" 5/8"X6" TITEN HD (4X5) V-0" V-0" 5'-0. 4'-6" 4'-0" T-9" T-6" 1) MIN CONC THICKNESS AND MIN EDGE DISTANCE SIM TO SILL PLATE ANCHORAGE TO CONCRETE SCHEDULE 2) FOR SHEARWALL ANCHORAGE REFER TO SHEARWALL SCHEDULE. 3) EXTERIOR WALL HEIGHT OF CONTINUOUS WALL STUDS FROM FOUNDATION TO THE NEAREST POINT OF LATERAL SUPPORT (CEILING, ROOF OR FLOOR DIAPHRAGM). 4) MECHANICALLY GALVANIZED OR STAINLESS STEEL. 5) CONC THICKNESS AND MIN EDGE DISTANCE SIM TO 1/2"X6" TITEN HD 309.7. INTERIOR WALLS SHALL BE SHEATHED ON AT LEAST ONE SIDE (DRYWALL ACCEPTABLE) OR PROVIDED WITH BLOCKING AT 4'-0" O.C. VERTICALLY. 309.8. EXTERIOR WALLS SHALL BE SHEATHED FULL HEIGHT WITH MINIMUM 1/2" GYPSUM BOARD AT THE INTERIOR AND WOOD STRUCTURAL PANEL SHEATHING AT THE EXTERIOR PER NOTE 303.4. 309.9. AT SHEAR WALL LOCATIONS, ALL VERTICAL PANEL JOINTS SHALL OCCUR OVER STUDS AND ALL HORIZONTAL PANEL JOINTS SHALL OCCUR OVER HORIZONTAL BLOCKING. 309.10. STUD SIZE SHALL BE BASED ON WALL HEIGHT, THICKNESS, AND FINISHES AS SHOWN ON THE ARCHITECTURAL DRAWINGS AND SELECTED PER THE WALL STUD SCHEDULES BELOW, UNO PER PLAN. DEFLECTION LIMITS PER NOTE 118.1.6 SHALL APPLY. 309.10.1. EXTERIOR WALL STUD SCHEDULE: EXTERIOR WALL STUD SCHEDULE - SYP, WIND -I IOMPH, EXP "B" MAX LATERALLY UNSUPPORTED STUD HEIGHT('X4)(5)(7) EXT WALL W/STUCCO OR EXT WALL W/ BRICK VENEER EXT WALL W/ FLEXIBLE PLASTER COVERING COVERING 2) COVERING STUD SIZE AND SPACING GRADE SUPPORTING ONE TWO ONE TWO ONE TWO ROOF + FLOOR + --LOORS + ROOF + FLOOR + FLOORS + ROOF + FLOOR + --LOORS + F+ + F+ F+ F+ F+ CEILING R00 ROOF CEILING R00 R00 CEILING R00 R00 CEILING CEILING CEILING CEILING CEILING CEILING ZX4 @ 24" O.C. STUD 10' 0" 10, 0" 10, 0" #2 10'-01, 1D'-O" - 2X4 @ 16" O.C. STUD 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" #2 11'-0" 101-0" 11'-o" 10'-0" 11'-0" 10'-0" 2X4 @ 12" O.C. STUD 10'-0" 10'-0" 1D'-O" 10'-0" 10'-0" " 10'-0 #2 12'-0" 10%0" 12'-0" 10'-0" 12'-0" 10'-0" 2X6 @ 24" O.C. STUD 10'-0" 10'-0" 10'-0" " " 10'-0" 10'-010'-0 #2 IT-3" 12'-3" 10'-0' 15'-3" 12'-3" 10'-0" 16-0" 12'-3" 10'-0' STUD 10'-0" 10'-0" 10'-0" 10'-C" IT-o" 10'-0" 10'-0" 10'-0" 10'-0" 2X6 @ 16" O.C. k2 15'-3" 14'-9" 13'-0" 17'-6" 15'-6" 13'-0" 19'-3" 15'-6" 13'-0" STUD 10'-0" 10'-0" 10'-0" 10'-W 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 2X6 @ 12" O.C. #2 16'-9" 16'-6" 15'-3" 19'-3" 18'-3" 15'-3" 21'-3" I8'-3" 15'-3" DOUBLE 2X6 016" O.C.(6) #2 19'-3" 19'-3" 1T-0" 22%3" 22'-0" 19'-3" 23'-3" 22'-6" 1T-3" DOUBLE 2X6 012" O.C.(6) #2 21'-6" 21'-3" 21'-0" 23'-3" 23'-3" 22'-6" 23'-3" 23'-3" 22'-6" 2X8 @ 16" O.C. #2 20'-3" 20'-0" 18'-9" 23'-3" 22'-3" 18'-9" 24'-0" 22'-0" 18'-9" 2X8 @ 12" O.C. #2 22'-6" 22'-3" 22'-0" 24%0" 24'-0" 22'-C" 24'-0" 24'-0" 22'-0" 1-1/2"X5-1/2"@ 16" 0-C. LSL 1.3E 14'-9" 14'-6" 14'-3" 17'-0" 16'-9" 16'-6" 18'-9" 18'-6" 17'-9" 1-1/2"X5-1/2"@ 12" O.C. LSL 1.3E 16'-3" 16%0" 15'-9" 18'-9" 18'-6" 18'-3" 20'-9" 20'-6" 20'-3" DOUBLE 1-1/2"X5-1/2" @ 16" D.C.(" LSL 1.3E 18'4" 18'-6" 18'-3" 21'-6" 21'-3" 21'-C" 24'-0" 23'-9" 23'-6" DOUBLE 1-1/2"X5-1/2" @ 12" 0.06) LSL 1.3E 20'-9" 20'-6" 20'-3" 24'-0" 23'-6" 23'-3" 24'-0" 24'-0" 24'-O" 1-3/4"X5-1/2"@ 16" O.C. LSL 1.55E 16'-6" 16-3" 16-0" 19'-C" 18'-9" 18'-6" 21'-0" 20'-9" 20'-6" 1-3/4"X5-1/2"@ 12" O.C. LSL 1.55E 18'-3" 18%0" 17-9" 21'-0" 20'-9" 20'-6" 23'-3" 23'-0" 22'-9" DOUBLE 1-3/4"X5-1/2" @ 16" D.C.(') LSL 1.55E 21'-0" 20'-9" 20'-6" 24'-0" 24'-0" 24'-0" 24'4- 24'-0" 24'-0" DOUBLE 1-3/4"X5-1/2" @ 12" 0.03j LSL 1.55E 23' 3" 23' 0" 22' 9" 24' 0" 24' 0" 24' 0" 24' 0" 24' 0" 24' 0" 1) LISTED HEIGHTS ARE DISTANCES BETWEEN POINTS OF LATERAL SUPPORT PLACED PERPENDICULAR TO THE PLANE OF THE WALL. 2) DOES NOT INCLUDE CASES WHERE BRICK WEIGHT IS SUPPORTED BY STUDS VIA LINTEL ATTACHED TO STUDS OR BRICK RESTING ON WOOD FRAMING ABOVE. 3) DOUBLE 1 3/4- LSL STUDS SHALL BE CONNECTED WITH SDW22 SCREWS (3-3/8"XO.22") @ 6" O.C. STAGGERED 4) REFERENCE IRC TABLES R602.3(5) AND R602.3(6). 5) DEFLECTION CRITERIA ARE AS FOLLOWS: H1360 FOR STUCCO, H/240 FOR BRICK VENEER, H/180 FOR FLEXIBLE FINISHES WITH DRYWALL INTERIOR FINISH. WHERE INTERIOR FACE OF THE WALL IS COVERED WITH PLASTER, DEFLECTION LIMITS H/360 SHALL BE USED EVEN WITH BRICK OR FLEXIBLE EXTERIOR COVERINGS. 6) BUNDLED STUDS SHALL BE CONNECTED TO EACH OTHER PER TYPICAL NAILING SCHEDULE (NOTE 302.8) 7) PROVIDE ADD'L NAILS AT TOP AND BOT PLATE TO STUD CONNECTION AS FOLLOWS: STUDS > 10'-0" ONE ADD'L NAIL EA CONNECTION STUDS > 14'-0" TWO ADD'L NAILS EA CONNECTION STUDS > 18'-0" - THREE ADD'L NAILS EA CONNECTION STUDS > 22'-0" AND UP TO 24'-0" - FOUR ADD'L NAILS 309.10.2. INTERIOR WALL STUD SCHEDULE: INTERIOR WALL STUD SCHEDULE - SYP MAX LATERALLY UNSUPPORTED STUD HEIGHTI') SUPPORTING STUD SIZE AND SPACING GRADE ONE FLOOR + TWO FLOORS + ROOF +CEILING ROOF + CEILING ROOF + CEILING STUD 1D'-o" 2X4 @ 24' O.C. (2) #z 10'-0" - 2X4 @ 16" O.C. - STUD 10'-0" lo'-o" #2 12'-9" 10'-0" 2X4 @ 12" O.C. STUD 1D'-0" 10'-0" #2 14'-9" 11'-0" STUD 10'-0" 10'-0" 2X6 @ 24" O.C!21 #2 19'-6" 13'-6" 12'-15" STUD 10'-0" 10'-0" 10'-0" 2X6 @ 16" O.C. #2 23'-3" 16-6" 15'-6" 2X6 @ 12" O.C. STUD 10'-0" 10'-0" 10'-0" #2 23'-3" 21'-3" 18'-o" 1) LISTED HEIGHTS ARE DISTANCES BETWEEN POINTS OF LATERAL SUPPORT PLACED PERPENDICULAR TO THE PLANE OF THE WALL. 2) AT SHEARWALLS, MAX STUD SPACING SHALL BE LIMITED TO 16" O.C. 309.11. WHERE "BALLOON FRAMED WALL" IS INDICATED ON PLAN, STUDS SHALL BE CONTINUOUS AS INDICATED WITHOUT TOP PLATES AT INTERMEDIATE FLOORS OR LOW CEILING/ROOF LEVELS. A SINGLE SET OF TOP PLATES SHALL BE PROVIDED ONLY AT THE TOP OF THE BALLOON -FRAMED WALL. 309.12. TYPICAL WALL OPENING SHALL BE FRAMED AS FOLLOWS: } �T/ PL PEY R ARCH c - TOP PLATES ��. CRIPPLE STUDS MATCHING NUMBER WITH JACK \, STUDS BELOW --` CRIPPLE STUD ABOVE HEADER. SPACING TO MATCH TYPICAL WALL FRAMING ADJACENT FULL HEIGHT KING STUD TO END OF HEADER ATTACHMENT PER THE TYPICAL NAILING SCHEDULE (NOTE 302.8) HEADER. BUILT UP PER TYPICAL NAILING SCHEDULE (NOTE 302.8) FOR 2X LUMBER OR NOTE 303.12.2 FOR LVL BEAMS KING STUDS CONTINUOUS FROM SILL PLATE TO TOP PLATE JACK STUDS CONTINUOUS FROM SILL PLATE TO UNDERSIDE OF HEADER \� ROUGH OPENING. REF ARCH WINDOW SILL PLATE PER WINDOW SILL PLATE SCHEDULE CRIPPLE STUD BELOW OPENING B"A' -- SILL (BOTTOM) PLATE PEA ARCH 309.13. HEADERS SHALL HAVE NOT LESS THAN ONE JACK STUD AND ONE KING STUD EACH END OR BE CONNECTED WITH AN APPROVED FRAMING ANCHOR. 309.14. HEADERS ARE NOT REQUIRED AT OPENINGS UP TO 6-0" WIDE IN INTERIOR NON -BEARING WALLS WHERE THE WALL HEIGHT ABOVE THE OPENING IS LESS THAN 2'4'. SUCH LOCATIONS SHALL BE NOTED "N.H.R." ON PLAN. A FLAT 2x MEMBER EQUAL TO WALL WIDTH MAY BE USED: TI PL I i PEJ a TOP PLATES -CRIPPLE STUDS NOT REQUIRED F-4 KING STUD CONTINUOUS FROMSILL PLATE TO TOP T/ROUGH OPENING I - PLATE. ATTACHMENT PER THE TYPICAL NAILING ER J, `� ARCH �i SCHEDULE (NOTE 302.8) FLAT 2X HEADER MATCHING WIDTH OF THE WALL FRAMING -JACK STUD ROUGH OPENING. REF ARCH 309.15. THE MINIMUM NUMBER OF KING STUDS ADJACENT TO AN OPENING SHALL BE DETERMINED BASED ON WALL HEIGHT AND OPENING WIDTH PER THE KING STUD SCHEDULE BELOW: KING STUDS AT EXTERIOR WALL SCHEDULE - WIND: 110 MPH, EXP "B" {3I NUMBER OF KING STUDS(') WALL HEIGHT STUD LUMBER SIZE GRADE 1 I 2 I 3 I 4 I 5 MAX ROUGH OPENING WIDTH 2X4 SYP STUD 8'-0" 18'-0" 24'-0" 2X6 SYP STUD 8'-0" 18'4" 24'-0' 2X4 SYP #2 T-0" 6-0" 10'-0" 14'-C" 18'-0" 2X6 SYP #2 V-0" 20'-0' 24'-0' 2X4 SYP #2 2'-6" 5'-0' 8'-0' 11'4' 14'-0- 12-4" 2X6 SYP #2 8'-0" 16-0" 24'-0' 2X6 SYP #2 5-0" 12'-0" 18'-0' 24'-0' 14'-0" 2X8 SYP #2 V-0" 20'-0' 24'-0' 2X6 SYP #2 3'-0" 8'-0" 13'-0" 18'-C" 23'-0' lfi'-0" 2X8 SYP #2 6D" 14'-0" 22'-0' 24'-0' 2X6 SYP #2 T-O" 8'-0" 12'-C" 16-0" 18'-0" 2X8 SYP #2 5'-0" 11'-0" 18'-0" 24'-0" 2X6 SYP #2 W-O" 6-0" 8'-0" 10'-0' 20'-D" 2X8 SYP #2 W-0" V-0" 14'-0" 19'-0" 24'-0' 2X6 SYP #2 4' 22-0" V-0" 8'-0" '-V 2X8 SYP #2 T-0" 6-0" 10'-0" 14'-0" 18'-0' 24'-0" 2X8 SYP #2 T-O" 8'-0" 11'-0" 14'-0" 1) NUI4BER OF KING STUDS SHOWN IS FOR EACH SIDE OF THE OPENING. KING STUDS ATTACHED TOGETHER PER TYPICAL NAILING SCHEDULE 2 BASED ON 1RC R602.7.5 3) EACH KING STUD SHALL CONNECT 70 TOP AND BOTTOM PLATE PER TYPICAL NAILING SCHEDULE NOTE 302.8. ADDITIONAL NAILS SHALL BE PROVIDED AT EACH KING STUD PER NOTES OF EXTERIOR WALL STUD SCHEDULE (NOTE 309.10.1) ACCORDING TO THE STUD HEIGHT. 309.16. IN VAULTED CEILING AREAS, EXTERIOR WALL STUDS SHALL BE CONTINUOUS FROM SILL PLATE TO THE FULL VAULTED CEILING HEIGHT PER NOTE 309.1. STUD SIZE AND SPACING SHALL BE SELECTED BASED ON THE ACTUAL STUD HEIGHT AT EACH LOCATION. KING STUDS ADJACENT TO OPENINGS WITHIN VAULTED WALLS SHALL EXTEND CONTINUOUSLY FROM THE SILL PLATE TO THE TOP OF THE VAULTED CEILING AND SHALL BE LATERALLY BRACED BY THE ROOF OR CEILING FRAMING AT THE TOP AS FOLLOWS: / TOP PLATES, TYPICAL NO TOP PLATES ALLOWED MID STUD HEIGHT KING STUDS AT SIDE OF OPENING CONTINUOUS TO TOP PLATES. SELECTED PER KING STUD \ SCHEDULE BASED ON ACTUAL STUD HEIGHT AT EACH LOCATION \HEADER JACK STUDS REGULAR STUDS CONTINUOUS FROM SILL TO TOP PLATE 309.17. WINDOW OPENINGS SHALL HAVE SILL PLATES SIZED AND SELECTED PER THE SILL PLATE SCHEDULE BELOW. ADDITIONAL SILL PLATES MAY BE REQUIRED AT WIDER OPENINGS. REFER TO THE ARCHITECTURAL DRAWINGS FOR OPENING DIMENSIONS. WINDOW SILL PLATE SCHEDULE. MAX OPENING WIDTH BASED ON QUANTITY AND SIZE OF WINDOW SILL PLATES(lX4) -WIND: 110MPH, EXP "B" QUANTITY OF WINDOW SILL PLATES WALL THICKNESS 1 �2X3X5) 3(2X3X5) 4(2X3X5) 2X4 6'-3" 8' 1" 9'-3- 2X6 10'-1" 12'-8" 14'-6" 16'-0" 2X8 13' 3" 16' 9" 19' 3" 2V-3" 1) THIS SCHEDULE I5 BASED ON A MAXIMUM TRIBUTARY HEIGHT TO THE WINDOW SILL OF 10'-0". THIS TRIBUTARY HEIGHT MAY REPRESENT EITHER THE DISTANCE FROM THE FLOOR TO THE WINDOW HEADER OR THE VERTICAL DISTANCE BETWEEN TWO HEADERS IN CASES WHERE OPENINGS ARE VERTICALLY ALIGNED WITHIN THE SAME WALL. SILL PLATES SHALL BE CONTINUOUS BETWEEN KING STUDS ON SIDES OF OPENING. 2) CONNECT EACH ADDITIONAL SILL PLATE TO THE PLATE BELOW USING 10D NAILS (3" X 0.148") SPACED AT 12" ON CENTER, STAGGERED, 3) EACH SILL PLATE SHALL BE CONNECTED TO THE ADJACENT FULL HEIGHT KING STUD AS REQUIRED PER TYPICAL NAILING SCHEDULE. 4) THE SILL PLATE SCHEDULE MAY BE USED AS A REFERENCE FOR DETERMINING THE SIZE OF THE BOTTOM PLATE OF A SOFFIT IN AN EXTERIOR WALL WHERE NO HEADER IS REQUIRED OR WHERE THE HEADER IS INSTALLED DIRECTLY BENEATH THE TOP PLATES AND FRAMED DOWN TO ACHIEVE THE REQUIRED OPENING HEIGHT. 5) CONNECT FIRST WINDOW PLATE TO THE CRIPPLE STUDS PER TYPICAL NAILING SCHEDULE "TOP OR SOLE PLATE TO STUD CONNECTION" REQUIREMENT 309.18. WHERE A LOW ROOF INTERSECTS AN EXTERIOR WALL AT MID -HEIGHT, EXTERIOR WALL SHEATHING SHALL BE INSTALLED CONTINUOUSLY FROM THE SILL PLATE TO THE TOP PLATE, THROUGH THE LOW ROOF FRAMING: ROOF/CEILING FRAMING Vv S * 1 ........................... .ALIAKSEI PATSEVICH .%.............. 130521•r • �O,c �'•�I �ENSE�•'" N•• ASS/• NGX� 1 O E N ice_ AL w O O Z Z W Z 0 W Z W z Z O 0 J M cn � O m U L7 Z lnlC W z W LL_ L7 Wiz W O ~ 0 J 114- _ --q U X mLu Ln 7 Q L. in�- cr ,--1 00 N REVISIONS 0 DATE Ln N �O 0 . PROJECT NAME 101 CROSS CREEK GARAGE ADDITION PROJECT ADDRESS 101 CROSS CREEK DR GRAPEVINE, TX PROJECT NUMBER S26129 CHECKED BY - AP SHEET DATE - 05/04/2026 SCALE 24X36 SHEET:1/2"=V-0" EXTERIOR WALL FRAMING LOW ROOF FRAMING. NAILER/BLOCKING AS REQ'D CITY (IF GRAPEVINE THIS PAGE RELEASE[ FOR CONSTRUCTION RELEASE DOES NC T AL THORIZE ANY WO tK IN EXTERIOR WALL SHEATHING CONFLICT WITH THE BUILDING 0`"16bE OR ZONING CONTINUOUS FROM SILL PLATE T OP J PLATE, THROUGH LOW ROOF FRAI qG ORDINANCE Q SILL PLATE AT BOT OF WALL F_ _ FOUNDATION OR FRAMING BELO CITY APPROVED PUNS TO BEPT ON THE JOB SITE T ALL TIM . z 07/07/2C26 9:21 -91 AM BY: KELLY TAFT TSUPE: 1-3971 H N z o o BUILDING III ECTION &%SION: (J) RELEASE DOES NOT AjpPLY TO C=STRUCiION IN EASEMENTS OF b03LIC RICr-OF-WAY Lu p Lu ALL CHANGE MUST BE. 'PROVED. V) FRAMING PLAN NOTES FOR TYPICAL MATERIAL, INSTALLATION, AND STANDARD DETAIL REQUIREMENTS, REFER TO THE GENERAL FRAMING NOTES (GN301) AS FOLLOWS: ........................... ALIAKSEI PATSEVICH 2 JACK 1 KING 3 CRIPPLE STUDS BELOW i l i x /.. 2-PLY 2 JACK 1, KING 3 JACK J 3 KING Lu > J > .. O co i I Q .l J Q x Lu EL C!) w 0 Lu m ., �:D O �1 3 JACK 3 KING I I II 3 STUDS BELOW 161" TJI360 @ 16" O.C. 3 STUDS �► BELOW IN 2-PLY 2X6 LUS26-2 J >r. x M 2-PLY 1 3/4' `\ X 16" LV x 1101, I I I I I r 3 STUDS BELOW TYPICAL FASTENERS AND NAILING SCHEDULE — SEC. 302 LUMBER AND SHEATHING MATERIALS — SEC. 303 FRAMING PENETRATIONS — SEC. 304 TYPICAL ROOF FRAMING — SEC. 305 TYPICAL CEILING FRAMING — SEC. 306 TYPICAL FLOOR FRAMING — SEC. 307 TYPICAL WALL FRAMING — SEC. 309 TYPICAL DECK FRAMING — SEC. 308 TYPICAL MULTIPLY LVL BEAM CONNECTION - NOTES 303.12 AND 303.13 TYPICAL HANGER SCHEDULE - NOTE 303.14 STUD WALL SCHEDULES: EXTERIOR WALLS -NOTE 309A0.1 INTERIOR WALLS - NOTE 309.10.2 KING STUD SCHEDULE - NOTE 309.15 ADDITIONAL REQUIREMENT AT SHEAR WALL LOCATIONS, REFER TO SHEAR WALL PLANS AND SHEAR WALL GENERAL NOTES (GN401) SEE ALSO: GENERAL STRUCTURAL NOTES (GN100) FOR ADDITIONAL MATERIAL, INSPECTION, AND CONTRACTOR RESPONSIBILITY REQUIREMENTS. WHERE SPECIFIC NOTES OR DETAILS ARE SHOWN ON THE PLANS, THOSE SHALL GOVERN. CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 07/07/2026 9:21:51 AM BY: KELLY TAFT TSBPE: 1-3971 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY ALL CHANGES MUST BE APPROVED. ROOF 2ND FLOOR 1ST FLOOR/ FOUNDATION I i LEVEL KEY q 130521 ;` I �P�,� �'•���ENSE�••'•� �� W pOZ z 0 w z w Z Ill z Z Z 00W J M Ql boo �p U u � x w � w w � z z > '-' _j 0 Lu o_ z Lu X O r� @ x> m cn Q L oL Q 00 CV N REVISIONS DATE BY PROJECT NAME 101 CROSS CREEK GARAGE ADDITION PROJECT ADDRESS 101 CROSS CREEK DR GRAPEVINE, TX PROJECT NUMBER S26129 CHECKED BY - AP SHEET DATE - 05/04/2026 SCALE 24X36 SHEET:1/2"=1'-0" z z Q oc LL C� z Lu U J z w M O > Lu cI? J U w �� w LL ul) FRAMING PLAN NOTES -I JACK 2 KING 1/ D E: 2-PLY 2X12 i J 00 x M N _ N � ..• LSSR410-2 ,D-rLl 1 J/`t A 2 JACK %7- LUS210-3 WHO LRU26,TYP 0 ,-i .0 LVL x 2 JACK N N X N ... c].,[ - - "10-PLY 2X12 1 JACK 2 KING 1 KING co N FOR TYPICAL MATERIAL, INSTALLATION, AND STANDARD DETAIL REQUIREMENTS, REFER TO THE GENERAL FRAMING NOTES (GN301) AS FOLLOWS: TYPICAL FASTENERS AND NAILING SCHEDULE — SEC. 302 LUMBER AND SHEATHING MATERIALS — SEC. 303 FRAMING PENETRATIONS — SEC. 304 TYPICAL ROOF FRAMING — SEC. 305 TYPICAL CEILING FRAMING — SEC. 306 TYPICAL FLOOR FRAMING — SEC, 307 TYPICAL WALL FRAMING — SEC. 309 TYPICAL DECK FRAMING — SEC. 308 TYPICAL MULTIPLY LVL BEAM CONNECTION - NOTES 303.12 AND 303.13 TYPICAL HANGER SCHEDULE - NOTE 303.14 STUD WALL SCHEDULES: EXTERIOR WALLS -NOTE 309A0.1 INTERIOR WALLS - NOTE 309.10.2 KING STUD SCHEDULE - NOTE 309.15 ADDITIONAL REQUIREMENT AT SHEAR WALL LOCATIONS, REFER TO SHEAR WALL PLANS AND SHEAR WALL GENERAL NOTES (GN401) SEE ALSO: GENERAL STRUCTURAL NOTES (GN100) FOR ADDITIONAL MATERIAL, INSPECTION, AND CONTRACTOR RESPONSIBILITY REQUIREMENTS. WHERE SPECIFIC NOTES OR DETAILS ARE SHOWN ON THE PLANS, THOSE SHALL GOVERN. CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 07/07/2026 9:21:59 AM BY: KELLY TAFT TSBPE: 1-3971 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY ALL CHANGES MUST BE APPROVED. ROOF 2ND FLOOR 1ST FLOOR/ FOUNDATION LEVEL KEY ALIAKSEI PATSEVICH .A. .•.130521 OFS ..• ��• `1\iL'ONAL ENS~ W Q 0 Z z 0 W oa z w Z W z Z Z 00W J M Ql boo �p U .-� u w � w w � z z > '-' _j 0 Lu o_ z w X O x> m cn Q L CL Q ai 00 CV N REVISIONS DATE BY PROJECT NAME 101 CROSS CREEK GARAGE ADDITION PROJECT ADDRESS 101 CROSS CREEK DR GRAPEVINE, TX PROJECT NUMBER S26129 CHECKED BY - AP SHEET DATE - 05/04/2026 SCALE 24X36 SHEET: 1/2"=1'-0" z Q CL Z N z0 M a pa[ L.L (I? cl� U w LL 0 0 w oC = GN401. GENERAL SHEAR WALL NOTES. - TYPICAL DETAILS AND SCHEDULES 401. GENERAL 401.1. REFER TO GENERAL STRUCTURAL NOTES (SECTIONS 100 THROUGH 127) FOR ALL ADDITIONAL REQUIREMENTS APPLICABLE TO MATERIALS, FASTENERS, CONNECTORS, INSPECTIONS, DELEGATED DESIGN, SUBMITTALS, AND ALL OTHER WORK NOT SPECIFICALLY ADDRESSED IN THESE SHEAR WALL NOTES. IN CASES OF CONFLICT, THE MORE STRINGENT REQUIREMENT SHALL GOVERN PER NOTE 100.4• 401.2. THESE NOTES APPLY TO LATERAL BRACING SYSTEMS INCLUDING WOOD STRUCTURAL PANELS (WSP) SHEAR WALLS, PORTAL FRAMES, CONTINUOUSLY SHEATHED BRACED WALL PANELS, AND PROPRIETARY PREFABRICATED SHEAR WALL UNITS IN WOOD -FRAMED RESIDENTIAL CONSTRUCTION. 401.3. CONSTRUCTION SHALL CONFORM TO THE LATEST ADOPTED EDITIONS OF INTERNATIONAL BUILDING CODE, WFCM (AWC), AND NOS. WHERE THESE NOTES OR THE STRUCTURAL DRAWINGS IMPOSE A MORE STRINGENT REQUIREMENT, THAT REQUIREMENT SHALL GOVERN. 401.4. SHEAR WALLS ARE DESIGNATED ON PLAN (E.G., SW6, SW4, ETC.) AND SHALL BE CONSTRUCTED PER THE CORRESPONDING ROW OF THE SHEAR WALL SCHEDULE, WHICH GOVERNS SHEATHING, NAILING, FRAMING, BOUNDARY MEMBERS, AND ANCHORS FOR EACH WALL. 401.5. THE CONTRACTOR SHALL VERIFY ALL SHEAR WALL LOCATIONS, LENGTHS, HEIGHTS, AND HOLDOWN LOCATIONS AGAINST THE STRUCTURAL AND ARCHITECTURAL DRAWINGS PRIOR TO FRAMING. DISCREPANCIES SHALL BE REPORTED TO THE FOR IMMEDIATELY. 402. MATERIALS 402.1. SHEATHING 402.1.1. WSP SHEATHING SHALL COMPLY WITH APA PRP-108 (PLYWOOD) OR PRP-210 (OSB), PS 1 OR PS 2, AND SHALL BEAR A VALID APA GRADE STAMP. PANELS SHALL BE RATED EXPOSURE 1 OR EXTERIOR. (SEE NOTES 108.1-108.3). 402.1.2. MINIMUM PANEL THICKNESS, GRADE, AND SPAN RATING SHALL BE PER THE SHEAR WALL SCHEDULE AND NOTE 303.4. 402.1.3. WHERE GYPSUM WALLBOARD IS LISTED IN THE SHEAR WALL SCHEDULE, IT SHALL BE MINIMUM 1/2" CONFORMING TO ASTM C1396 AND FASTENED PER THE SCHEDULE. GWB SHALL NOT BE THE SOLE LATERAL -RESISTING ELEMENT UNLESS SPECIFICALLY DESIGNATED BY THE EOR. 402.2. FRAMING 402.2.1• ALL FRAMING LUMBER FOR BOUNDARY MEMBERS, CHORD STUDS, POSTS, AND SILL PLATES SHALL MEET THE SPECIES AND GRADE OF NOTE 303.2. WHERE THE SHEAR WALL SCHEDULE INDICATES MULTIPLE STUDS (E.G., (2) OR (3) STUDS), ALL SHALL BE INSTALLED AND CONNECTED PER NOTE 302.7. 402.2.2. WHERE A 3X SILL PLATE IS REQUIRED BY THE SCHEDULE, IT SHALL BE CONTINUOUS FOR THE FULL SHEAR WALL LENGTH. A 3X MEMBER SHALL NOT BE SUBSTITUTED WITH MULTIPLE 2X MEMBERS WITHOUT FOR APPROVAL. 402.3. FASTENERS AND CONNECTORS 402.3.1. FASTENER CORROSION PROTECTION SHALL BE PER NOTES 110.1-110.12 AND 111.1-111.9. NAIL TYPE, SIZE, AND QUANTITY SHALL BE PER THE SHEAR WALL SCHEDULE. SUBSTITUTIONS ARE NOT PERMITTED WITHOUT WRITTEN FOR APPROVAL, 402.3.2. HOLDOWNS, STRAPS, AND TENSION TIES SHALL BE SIMPSON STRONG -TIE OR APPROVED EQUAL, INSTALLED WITH THE FULL COMPLEMENT OF MANUFACTURER -SPECIFIED FASTENERS TO ACHIEVE RATED CAPACITY. ANCHOR BOLTS AND RODS SHALL BE INSTALLED PRIOR TO CONCRETE PLACEMENT PER NOTE 203.1. 403. SHEAR WALL CONSTRUCTION 403,1. SHEATHING INSTALLATION 403.1.1. WSP SHEATHING SHALL BE INSTALLED WITH THE LONG DIMENSION VERTICAL (PARALLEL TO STUDS) UNLESS THE SCHEDULE INDICATES HORIZONTAL. SHEATHING SHALL BE CONTINUOUS FROM SILL PLATE TO TOP PLATE WHERE POSSIBLE. (SEE NOTE 309.8.) 403.1.2. VERTICAL PANEL JOINTS SHALL OCCUR OVER STUDS; HORIZONTAL JOINTS SHALL OCCUR OVER FULL -DEPTH BLOCKING. PROVIDE 1/8" EXPANSION GAPS AT ALL PANEL EDGES AND ENDS. (SEE NOTES 309.9 AND 108.5.) 403.1.3• WHERE SHEATHING IS REQUIRED ON BOTH FACES, PANEL JOINTS SHALL BE OFFSET A MINIMUM OF ONE STUD SPACE BETWEEN FACES AND STAGGERED VERTICALLY. 403.2. NAILING 403.2.1. EDGE AND FIELD NAILING SHALL BE PER THE SHEAR WALL SCHEDULE. NAILS SHALL BE DRIVEN FLUSH; OVERDRIVEN NAILS SHALL BE SUPPLEMENTED PER NOTE 302.5. 403.2.2• WHERE SCHEDULE EDGE SPACING IS 2" OR 3", 3X SILL PLATES, DOUBLE BOUNDARY STUDS, AND 3X BLOCKING SHALL BE PROVIDED PER THE SCHEDULE TO PREVENT SPLITTING, 403.3. BOUNDARY MEMBERS 403.3.1. END STUDS SHALL BE MINIMUM (2) FULL -HEIGHT STUDS AT EACH END OF ALL SHEAR WALLS, INSTALLED CONTINUOUSLY FROM SILL PLATE TO TOP PLATE WITHOUT SPLICES AND CONNECTED PER NOTE 302.7. WHERE HOLDOWNS ARE REQUIRED, ADDITIONAL STUDS MAY BE REQUIRED AT HOLDOWN LOCATIONS - REFER TO HOLDOWN SCHEDULE FOR MINIMUM STUD QUANTITIES AT EACH HOLDOWN TYPE. WHERE THE QUANTITY OF STUDS IS SHOWN ON PLAN, THAT QUANTITY SHALL GOVERN OVER THE SCHEDULE. 403.3.2. BOUNDARY MEMBERS SHALL BEAR CONTINUOUSLY ON MEMBERS BELOW THAT TRANSFER OVERTURNING FORCES TO THE FOUNDATION. ALL BOUNDARY MEMBER LOAD PATHS SHALL BE CONTINUOUS. 403.4. BLOCKING 403.4.1• HORIZONTAL BLOCKING SHALL BE PROVIDED BETWEEN STUDS AT ALL HORIZONTAL SHEATHING PANEL JOINTS. BLOCKING SHALL BE MINIMUM 2x FULL -DEPTH, MATCHING STUD DEPTH, UNO PER SCHEDULE. 403.4.2. AT FLOOR LEVELS BETWEEN STORIES, FULL -DEPTH BLOCKING, RIM BOARD, OR CONTINUOUS FRAMING SHALL TRANSFER SHEAR THROUGH THE FLOOR WITHOUT INTERRUPTION. SEE STRUCTURAL DETAILS AND NOTES 307.6 AND 403.6. 403.5. SILL PLATE ANCHORING 403.5.1. SILL PLATES AT SHEAR WALL LOCATIONS SHALL BE ANCHORED PER THE SHEAR WALL SCHEDULE. ANCHOR BOLTS SHALL BE INSTALLED WITHIN 12" OF EACH END OF EACH SILL PLATE SEGMENT, UNLESS CLOSER SPACING IS REQUIRED. (SEE NOTES 309.5 AND 309.6.) 403.5.2. STANDARD CUT WASHERS SHALL BE PROVIDED AT SILL PLATE ANCHOR BOLTS AT SHEAR WALL LOCATIONS, UNO. WHERE THE SHEAR WALL SCHEDULE INDICATES SQUARE PLATE WASHERS, THEY SHALL BE MINIMUM 3"x3"x0.229" THICK. CUT WASHERS SHALL NOT BE SUBSTITUTED FOR PLATE WASHERS WHERE PLATE WASHERS ARE SPECIFICALLY REQUIRED BY THE SCHEDULE. 0'-4" MIN 1'- " MA ANCHOR BOLT SPACIIyG PER SHEAR WALL SCHEDULE,OR PER NOTE 309.6 I I MINIMUM 2 ANCHORS OLTS PER SEGMENT , SILL PLATE ANCHORING PLAN VIEW 403.6. SHEAR TRANSFER AT FLOOR AND ROOF LEVELS 403.6.1• SHEAR SHALL BE TRANSFERRED CONTINUOUSLY FROM THE ROOF DIAPHRAGM THROUGH EACH STORY TO THE FOUNDATION. THE LOAD PATH SHALL NOT BE INTERRUPTED WITHOUT WRITTEN FOR AUTHORIZATION. 403.6.1.1. WHERE A SHEAR WALL IS DESIGNATED AT A WALL WITH A GABLE END OR ATTIC WALL ABOVE THE TOP PLATE, THE SHEAR WALL SHEATHING AND NAILING REQUIREMENTS SHALL EXTEND CONTINUOUSLY FROM THE SILL PLATE OF THE DESIGNATED SHEAR WALL THROUGH THE TOP PLATE AND FULL HEIGHT OF THE GABLE OR ATTIC WALL TO THE TOP PLATES OF THE ROOF FRAMING ABOVE. THE SHEATHING AND NAILING SHALL BE PER THE SAME SHEAR WALL DESIGNATION UNLESS OTHERWISE NOTED ON PLAN. 403.6.2. SHEAR TRANSFER HARDWARE (BLOCKING, STRAPS, SHEAR PLATES) AT EACH FLOOR LEVEL SHALL BE INSTALLED AND NAILED PER THE STRUCTURAL DETAILS AND SHEAR WALL SCHEDULE BEFORE COVERING. 404. HOLDOWNS AND OVERTURNING RESTRAINT 404.1. HOLDOWNS SHALL BE PROVIDED AT LOCATIONS SHOWN ON PLAN AND SHALL BE INSTALLED WITH ALL MANUFACTURER -SPECIFIED FASTENERS IN ALL PREPUNCHED HOLES. 404.2. HOLDOWN ANCHOR RODS SHALL EXTEND FROM THE HOLDDOWN HARDWARE AND EMBEDDED INTO THE FOUNDATION. 404.3. CONTINUOUS ROD SYSTEMS SHALL INCORPORATE SHRINKAGE -COMPENSATING TAKE-UP DEVICES AT EACH FLOOR LEVEL AND SHALL BE TIGHTENED AFTER FRAMING AND BEFORE FINISHES, AND RE -TIGHTENED AS DIRECTED BY THE MANUFACTURER. 404.4. HOLDOWN ANCHORS SHALL BE INSTALLED PLUMB IN THE CORRECT LOCATION PRIOR TO CONCRETE PLACEMENT. SEE NOTE 203.1 FOR EMBEDDED HARDWARE REQUIREMENTS. 404.5. WHERE HOLDOWNS ARE INDICATED PER PLAN, ADDITIONAL REQUIREMENTS ARE AS APPLICABLE PER HOLDOWN SCHEDULE BELOW: HOLDOWN SCHEDULE HOLDOWN ANCHOR MIN ANCHOR EMBEDMENT MIN WOOD POST SIZE CALLOUT DIAMETER STHD14 (2)-2X STUDS 5THD14RJ - - (2)-2X STUDS HDUE3-SDS3 5/8" 1'-0. (2)-2X STUDS HDUE5-SDS3 5/8'. V-6" (2)-2X STUDS HDUE7-SDS3 5/8" V-6" (2)-2X STUDS HDUE9-SOS3.5 7/8" 1'-10" (3)-2X STUDS HDU13-SDS3.5 1" T-0" 4X8 POST HDUE17-SDS3.5 1" 2'-0" 6X6 POST DTT1Z 3/8" 1'-0" (1)-2X STUD DTT2Z 1/2" 1'-0" (2)-2X STUDS 404.6. WHERE HOLDOWN IS SHOWN PER PLAN IN A CORNER OF A WALL, THE CORNER FRAMING SHALL BE AS FOLLOWS: 404.6.1. PLAN VIEW AT EXTERIOR CORNER: HOLDOWN PER PLAN (SIM WITH STHD14 ON SIDE) BUNDLED STUDS OR POST PER PLAN OR PER HOLDOWN SCHEDULE WALL SHEATHING PANEL EDGE NAILING PER I- APPLICABLE SHEAR WALL CALLOUT 404.6.2. PLAN VIEW AT INTERIOR CORNER: -�� 0.148"X3 1-1/4" NAILS @ PANEL EDGE NAILING SPACING WALL SHEATHING PANEL EDGE NAILING PER APPLICABLE SHEAR WALL CALLOUT BUNDLED STUDS OR POST PER PLAN OR PER HOLDOWN SCHEDULE HOLDOWN PER PLAN (SIM WITH STHD14 ON SIDE) 405. PORTAL FRAMES 405.1. PORTAL FRAME ASSEMBLIES SHALL BE USED WHERE SPECIFICALLY CALLED OUT ON PLAN AND SHALL COMPLY WITH THE LATEST EDITION OF THE INTERNATIONAL BUILDING CODE. PORTAL FRAMES SHALL BE CONSTRUCTED WITH STUDS #2 GRADE OR BETTER. CONSTRUCTION DETAILS SHALL BE AS FOLLOWS: 405.1.1• SINGLE SIDE PORTAL FRAME SW-PFl: EXTENT OF HEADER WITH SINGLE PORTAL FRAME ROUGH OPENING WIDTH (T-0" MIN, 18'-0" MAX) a-Ir- 3: rw li• II 11: 'II aC) 14 I I li I I Ifi• •11 13 HEADER PER PLAN (MIN 2-PLY 2X12) • i • 11 �a : ----FASTEN SHEATHING TO HEADER WITH 0.131"X2-1/2" H NAIL IN 3" GRID PATTERN AS SHOWN -' is `9 ~ HEADER TO JACK STUD STRAP PER PORTAL FRAME u STRAP AT HEADER SCHEDULE. ADD'L STUD - u a REQUIRED WHERE MULTIPLE STRAPS REQUIRED. o STRAP LENGTH AS REQUIRED FROM TOP PLATES TO x Lu = ��T EXTEND 1'-4" PAST HEADER ..... . ... MIN DOUBLE STUDS AT ENDS. ADD'L STUDS MAY o BE INDICATED PER PLAN. FASTEN SHEATHING WITH -- - 0.131"72-1/2" NAILS @ 3"O.C. TO EACH STUD - SHEATHING SPLICES ACCEPTABLE WITHIN THE MIDDLE 2'-0" OF THE WALL. PROVIDE BLOCKING AND NAILING @ YO.C. STHD14 HOLDOWN +r: DOUBLE SILL PLATE AT PORTAL FRAME (2) 1/2" DIA ANCHOR BOLTS - WITH 7" EMBEDMENT INTO CONCRETE TI I I I I I I LJ LJ LJ 405.1.2. DOUBLE PORTAL FRAME SW-PF2: EXTENT OF HEADER WITH DOUBLE PORTAL FRAME ROUGH OPENING WIDTH (T-0" MIN, 18'-0" MAX) • IJ : GI li MI 14 41 I i h I • is : : �i : 3: :C 14 11 ' hl 14- •,}I 11 : r.11 4 13 : rl 114 1.1 .. 1• •rl .. :-REF SINGLE PORTAL FRAME FOR u -- NAILING/STRAPPING REQUIREMENTS ; I I I I I I I I I I I I I I I I I I I I 1 1 I I LJ LJ LJ LJ 405.1.3. PORTAL FRAME SECTION: � T/ PL PEY R ARCH TENSION STRAP ON OPPOSITE SIDE OF SHEATHING t--FASTEN KING STUD TO HEADER W/ (6) 0.148"73-1/4" NAILS T/RO PE RARCH-TOP PLATE TO HEADER W/ TWO ROWS OF 0.148"X3-1/4" NAILS SHEATHING SPLICES ACCEPTABLE WITHIN THE MIDDLE 2'-0" OF THE WALL. PROVIDE BLOCKING AND NAILING @ 3"O.C. ,.---STHD14 HOLDOWN ---,,-ANCHOR BOLTS DOUBLE SILL PLATES a J 405.1.4. PORTAL FRAME STRAP AT HEADER SCHEDULE: PORTAL FRAME STRAP AT HEADER SCHEDULE WALL WIDTH MAXIMUM OPENING WIDTH (#2 GRADE REQ'D) WALL HEIGHT STRAP DETAILS 9'-0" 16•0" 181•0" 10'-0" MAX STRAP CS16 (2)-CS16 (2)-CS16 2X4 12'-0" MAX STRAP (2) CS16 (2)-CS16 N/A 2X6 12'-0" MAX STRAP CS16 (2)-CS16 (2)-CS16 OR WIDER 406. SPECIAL BRACING ELEMENTS 406.1. PROPRIETARY PREFABRICATED SHEAR WALL PANELS (E.G., SIMPSON STRONG -WALL OR EQUAL) SHALL BE THE EXACT TYPE AND SIZE DESIGNATED ON PLAN. ANCHOR BOLTS AND HARDWARE SHALL BE INSTALLED PER STRUCTURAL DETAILS AND THE MANUFACTURER'S TEMPLATE PRIOR TO CONCRETE PLACEMENT. SUBSTITUTIONS REQUIRE WRITTEN FOR APPROVAL. 407. INSPECTION AND QUALITY CONTROL 407.1. SHEAR WALL FRAMING, SHEATHING, NAILING, HOLDOWNS, AND ANCHOR HARDWARE SHALL BE INSPECTED AND APPROVED PRIOR TO COVERING BY THE BUILDING OFFICIAL OR A QUALIFIED INSPECTOR AND/OR REPRESENTATIVE OF THE FOR WHEN REQUIRED BY THE LOCAL JURISDICTION. COVERING WITHOUT PRIOR INSPECTION AND APPROVAL IS NOT PERMITTED. THE CONTRACTOR SHALL PROVIDE ADEQUATE NOTICE AND ACCESS FOR INSPECTION. 407.2• WHERE SPECIAL INSPECTIONS ARE REQUIRED BY THE APPLICABLE BUILDING CODE OR THE LOCAL JURISDICTION, INSPECTIONS FOR NAILING, BOLTING, ANCHORING, AND HOLDOWN INSTALLATION SHALL BE PER THE STATEMENT OF SPECIAL INSPECTIONS (NOTE 125.1). HOLDOWN RODS AND ANCHOR BOLTS SHALL BE INSPECTED PRIOR TO CONCRETE PLACEMENT FOR CORRECT SIZE, LOCATION, EMBEDMENT, AND PROJECTION, SPECIAL INSPECTIONS ARE NOT REQUIRED FOR STRUCTURES CLASSIFIED AS R-3 OCCUPANCY UNLESS SPECIFICALLY REQUIRED BY THE LOCAL JURISDICTION OR THE AUTHORITY HAVING JURISDICTION (AHJ). 407.3. WHERE DISCREPANCIES ARE IDENTIFIED, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE FOR AND SHALL NOT CONCEAL THE AFFECTED AREA UNTIL WRITTEN DIRECTION IS RECEIVED. A COPY OF THE SHEAR WALL SCHEDULE AND APPLICABLE DETAILS SHALL BE MAINTAINED ON THE JOBSITE THROUGHOUT FRAMING. 408. A NOTE ON FLEXIBLE STRUCTURAL SHEATHING SUBSTITUTION 408.1. WHILE THE MANUFACTURER'S PUBLISHED DESIGN VALUES MAY INDICATE THAT CERTAIN FLEXIBLE STRUCTURAL SHEATHING PRODUCTS ARE SUITABLE FOR RESISTING LATERAL LOADS, THE ENGINEER OF RECORD DOES NOT RECOMMEND THE USE OF ANY FLEXIBLE STRUCTURAL SHEATHING AS A SUBSTITUTE FOR WOOD STRUCTURAL PANEL SHEATHING AT ANY DESIGNATED SHEAR WALL LOCATION. INDEPENDENT TESTING CONDUCTED AT CLEMSON UNIVERSITY, THE UNIVERSITY OF OKLAHOMA, AND THE APA RESEARCH CENTER CONCLUDED THAT FLEXIBLE STRUCTURAL SHEATHING MATERIALS OVERSTATE THEIR LATERAL LOAD RESISTANCE BY AS MUCH AS 42 PERCENT WHEN COMPARED TO THEIR PUBLISHED DESIGN VALUES. THE CONTRACTOR AND OWNER ARE DIRECTED TO APA PRODUCT ADVISORY SP-1186, PERFORMANCE OF FLEXIBLE STRUCTURAL SHEATHING (INDEPENDENT EVALUATIONS OF PUBLISHED DESIGN VALUES), JULY 2018, FOR A FULL DISCUSSION OF THESE FINDINGS. FLEXIBLE STRUCTURAL SHEATHING PRODUCTS SHALL NOT BE SUBSTITUTED FOR WSP SHEATHING AT SHEAR WALL LOCATIONS WITHOUT PRIOR WRITTEN APPROVAL FROM THE EOR. 409. SHEAR WALL SCHEDULE WOOD STRUCTURAL PANEL SHEAR WALL SCHEDULE (WIND ONLY) CONNECTION REQUIREMENT SHEAR Q 0 Q WALL WALL FLOOR/ROOF CALLOUT SHEATHING WALL SHEATHING PANEL ANCHOR BOLT SILL PLATE NAILING TOE NAIL AT PANEL EDGE FLANGE PER PLAN EDGE/FIELD NAIL SPACING SPACING TO RIM/BLKG BELOW RIM/BLKG NAILING NAILING 0.131"X2-1/2" 1/2"0, 7" EMBED 0.131"X3-1/2" 0.131"X3" 0.131"X2-1/2" 0.131"XZ-1/2" SW6 7/16" 6" O.C./12" O.0 (6) 4'-0" O.C. 6" O.0 4' O.C. 6" O.C.("'1 6" O.C. SW4 7/16" 4" O.C./12" O.0 (6) 2'-8" O.C. 4" O.C. (3) 3" O.C. 4" O.C. (3) 4" O.C. SW3 7/16" 3" O.C./12" O.C.161 T-0" O.C. 3" O.C. {4I 2" O.C. 3" O.C. (4X11) (2) ROWS @ 4" O.C.ISI (2) ROWS @ 2" 0 C (2) ROWS @ (2) ROWS @ SW2 7/16" 2" O.C.112. O.C.{6) 1' 4" O,C. 4" O.C.13;(S) 4' O.C.(3„S) 4" D.C.'-) PORTAL FRAME CALLOUTS SW-PFI I SINGLE PORTAL FRAME. REF NOTE 405.1.1 FOR FRAMING REQUIREMENTS SW-PF2 DOUBLE PORTAL FRAME REF NOTE 405.1.2 FOR FRAMING REQUIREMENTS 1) ALLEXTERIOR WALLS NOT DESIGNATED AS SHEARWASLL SHALL BE SHEATHED SIM TO SW6, PROVIDE ANCHOR BOLTS @ 72" O.C. 2) ADJOINING PANEL EDGES STAGGERED ON EACH SIDE OF WALL SHALL BE OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS 3) MIN 1-1/4" RIM/BLOCKING THICKNESS BELOW 4) MIN 1-1/2" RIM/BLOCKING THICKNESS BELOW, CAN BE REPLACED WITH TWO ROWS OF NAILS @ 4" O.C. INTO 1-1/4" RIM/BLOCKING 5) PROVIDE ADDITIONAL JOIST OR BLOCKING FOR EACH ADDITIONAL ROW OF NAILS 6) PANEL FIELD NAILING SHALL BE WE' O.C. WHEN STUDS WITHIN SHEAR WALL ARE SPACED 16" O.C. OR LESS. WHEN STUDS ARE SPACED @ 24"O.C. FIELD SHALL MATCH PANEL EDGE NAILING 7) 'WHERE NAILING IS SPECIFIED AT 2. O.C., ADDITIONAL 2X MEMBER IS REQUIRED AT ALL ADJOINING PANEL EDGES (STUDS, PLATES, BLOCKING). CONNECT ADDITIONAL FRAMING TOGETHER W'/ 0.131" X 3" NAILS AT SAME SPACING AS SPECIFIED PANEL EDGE NAILING 8) NAILS SHALL BE LOCATED AT LEAST 3/8" FROM PANEL EDGES 9) REF 303.4 FOR SHEATHING REQUIREMENTS 10) AT GABLE END, ROOF SHEATHING NAILING SHALL BE LIMITED TO 4" O.C. REF NOTE 305.20 FOR ADDT INFORMATION 11) NAILING INTO TJI JOIST FLANGE IS LIMITED TO 4" O.C. AT SW3, ADDITIONAL JOIST OR ROW OF BLOCKING SHALL BE PROVIDED AND FLOOR/ROOF PANEL EDGE NAILING SHALL BE (2) ROWS @ 4" O.C. 410. STANDARD DETAILS 410.1. ROOF SHEAR TRANSFER DETAILS: 410.1.1. SHEAR CONNECTION REQUIREMENTS AT HIP ROOF FRAMING SHALL BE AS FOLLOWS: ROOF SHEATHING PANEL EDGE NAILING INTO BLOCKING 0 FULL DEPTH SOLID BLOCKING WITH VENT HOLES AS REQUIRED. PROVIDE AT ALL RAFTERS 2X10 OR LARGER, ALL TJI RAFTERS, AND AT ALL SHEAR WALL LOCATIONS T/PL WITH PANEL EDGE NAILING 4" O.C. OR LESS (I.E. SW4, SW3, SW2) FAR TOE NAIL NAIL AT RIM/BLKG PER SHEARWALL SCHEDULE WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE 1O SHEAR WALL PER PLAN CALLOUT 410.1.2. SHEAR CONNECTION REQUIREMENTS AT GABLE END ROOF FRAMING SHALL BE AS FOLLOWS: VT/PL PER ARCH ROOF SHEATHING PANEL EDGE NAILING INTO BLOCKING 5O ATTIC FULL DEPTH SOLID BLOCKING. TOE NAIL NAIL AT RIM/BLKG PER SHEARWALL SCHEDULE WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE O WALL SHEATHING CONTINUOUS OVER GABLE END WALL SIMILAR �T/PL TO THE REQUIREMENT OF SHEAR WALL CALLOUT BELOW TR ARCH WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE Ol SHEAR WALL PER PLAN CALLOUT 410.2. ELEVATED FLOOR SHEAR TRANSFER DETAILS: 410.2.1. INTERIOR SHEAR WALL WITH PARALLEL FLOOR FRAMING AT SW6 AND SW4: T FLOOR SHEATHING PANEL EDGE NAILING INTO JOIST 5O PERARCH+ BLOCKING CONNECTION REQUIREMENTS PER 307.7.3 JOIST ALIGNED DIRECTLY OVER WALL BELOW FLANGE NAILING PER SHEARWALL SCHEDULE WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE ( SHEAR WALL PER PLAN CALLOUT CAN BE EITHER SIDE OF WALL 410.2.2. PROVIDE ADDITIONAL JOIST OR BLOCKING AT INTERIOR SHEAR WALL WITH PARALLEL FLOOR FRAMING AT SW3 AND SW2 AS FOLLOWS (REQUIREMENTS BELOW ARE IN ADDITION TO ALL REQUIREMENTS OF 410.2.1): T/ADDITIONAL ROW OF FLOOR SHEATHING PANEL EDGE NAILING INTO PER ARCH JOIST/BLOCKING 50 I I ADDITIONAL JOIST OR BLOCKING FULL LENGTH OF SHEAR WALL ADDITIONAL ROW OF FLANGE NAILING AT BLOCKING PER SHEARWALL SCHEDULE 410.2.3. INTERIOR SHEAR WALL WITH PERPENDICULAR FRAMING AT SW6 AND SW4: FLOOR SHEATHING PANEL EDGE NAILING INTO BLOCKING 05 T/ FLFR ARCH ARCH JOIST BLOCKING FLANGE NAILING PER SHEARWALL SCHEDULE WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE 10 SHEAR WALL PER PLAN CALLOUT CAN BE EITHER SIDE OF WALL 410.2.4. AT INTERIOR SHEAR WALL WITH PERPENDICULAR FRAMING AT SW3 AND SW2, PROVIDE ADDITIONAL ROW OF BLOCKING SIMILAR TO REQUIREMENTS OF 410.2.2 AT PARALLEL FRAMING. 410.2.5. AT INTERIOR EDGE OF FLOOR FRAMING, LSL RIM JOISTS SHALL BE PROVIDED IN LIEU OF TJI JOIST, WITH TOE NAILING AS REQUIRED IN LIEU OF FLANGE NAILING. SEE EXTERIOR SHEAR WALL 410.2.6. TM PEY R ARCH 410.2.7. REQUIREMENTS FOR SIMILAR CONDITIONS. AT INTERIOR SHEAR WALLS ABOVE THAT DO NOT STACK WITH WALLS BELOW (SIM AT PERPENDICULAR FRAMING BELOW WITH BLOCKING UNDER SHEAR WALL IN LIEU OF JOISTS. REF 307.7.3 FOR BLOCKING DETAILS): SHEAR WALL ABOVE PER PLAN CALLOUT WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL �? SCHEDULE Ol -SILL PLATE NAILING TO JOIST BELOW PER SHEAR WALL SCHEDULE O3 --FLOOR JOIST ALIGNED UNDER WALL ABOVE (ADDITIONAL JOISTS REQUIRED AT SW3 ANS SW2), OR BEAM PER PLAN CALLOUT EXTERIOR SHEAR WALL WITH PERPENDICULAR FLOOR FRAMING: SHEAR WALL ABOVE PER PLAN CALLOUT SILL PLATE NAILING TO RIM PER SHEAR WALL SCHEDULE ( FOR SHEAR WALL CALLOUT ABOVE WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE Ol PER SHEAR WALL CALLOUT ABOVE T FLOOR SHEATHING PANEL EDGE NAILING INTO BLOCKING O5 PER ARCH PER SHEAR WALL CALLOUT BELOW WALL SHEATHING SHALL BE SPLICED OVER RIM WITH WALL SHEATHING PANEL EDGE NAILING lO AS APPLICABLE FOR RESPECTIVE SHEARWALLS RIM JOIST. SIZE AS REQUIRED PER SHEAR WALL SCHEDULE TOE NAILING PER SHEARWALL SCHEDULE WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE () PER SHEAR WALL CALLOUT BELOW SHEAR WALL BELOW PER PLAN CALLOUT 410.2.8. EXTERIOR SHEAR WALL WITH PARALLEL FLOOR FRAMING SHALL BE SIMILAR TO EXTERIOR SHEAR WALL WITH PERPENDICULAR FRAMING NOTE 410.2.7 WITH FLOOR BLOCKING INSTALLED AS REQUIRED PER NOTE 307.7.1 410.2.9. AT OPEN WEB TRUSSES, INTERIOR SHEAR WALL WITH PARALLEL FLOOR FRAMING: (3) 0.131"X2-1/2" NAILS INTO 2X BLOCKING @ 48" O.C. FLOOR SHEATHING PANEL EDGE NAILING INTO JOIST 50 FLFR _ r PT/� Rwz�H - a 2X4 BRACE @ 48" O.C. WITH (3) FACE NAILS TOP AND (3) TOE NAILS BOT -SHEAR TRUSS ALIGNED DIRECTLY OVER WALL BELOW. TRUSS SHALL BE DESIGNED FOR DRAG FORCE AS s s INDICATED PER PLAN (OR MIN 250 PLF IF NO SPECIFIED) FLANGE NAILING PER SHEARWALL SCHEDULE WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE Ol SHEAR WALL PER PLAN CALLOUT CAN BE EITHER SIDE OF WALL 410.2.10. AT OPEN WEB TRUSSES, INTERIOR SHEAR WALL WITH PERPENDICULAR FLOOR FRAMING SHALL BE SIMILAR TO 410.2.3 WITH TRUSS BLOCKING PROVIDED IN LIEU OF JOIST BLOCKING• TYPICAL TRUSS BLOCKING SHALL BE AS FOLLOWS: T/PEER > FLOOR SHEATHING PANEL EDGE NAILING INTO BLOCKING 50 PE� R om+ �� -TRUSS BLKG SHALL BE PROVIDED OVER ENTIRE LENGTH OF SHEARWALL PICTURE FRAME' BLOCKING WITH 2X4 TOP AND BOT PLATE AND 2X4 CRIPPLE -STUDS ADJACENT TO TRUSSES. SHEATHING AND NAILING [ SHALL MATCH REQUIREMENT FOR SHEAR WALL BELOW 0.131"X3" NAILS FROM BLOCKING TO TRUSS VERT @6"O.0 (MIN 4) EA SIDE T/P t -, PER L ARCH s OPEN WEB TRUSS PER PLAN Y - - - SILL PLATE NAILING BLOCKING TO TOP PLATE PER SHEAR WALL SCHEDULE O3 SHEAR WALL BELOW PER PLAN CALLOUT O ELEVATION ID tx FLOOR SHEATHING PANEL EDGE NAILING INTO BLOCKING 5 T/PLEB PANEL EDGE NAILING FOR SHEATHING AT BLOCKING PER SH AR WALL PE� RR°' SCHEDULE M "PICTURE F E" BLOCKING W/ SHEATHING SILL PLATE NAILING BLOCKING TO TOP PLATE PER SHEAR T/PL WALL SCHEDULE 3O PER�ARUI BLOCKING SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE Ol OPEN WEB FLOOR TRUSSES SECITON "A" 410.2.11. SHEAR CONNECTION REQUIREMENTS AT OPEN WEB TRUSSES AT EXTERIOR SHEAR WALLS WITH PERPENDICULAR FRAMING. AT SW3 AND SW2 CALLOUT PROVIDE 3X TRUSS BAND. SHEAR WALL ABOVE PER PLAN CALLOUT SILL PLATE NAILING TO RIM PER SHEAR WALL SCHEDULE O3 FOR SHEAR WALL CALLOUT ABOVE T/FGR ' WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL vEY R SCHEDULE OPER SHEAR WALL CALLOUT ABOVE FLOOR SHEATHING PANEL EDGE NAILING INTO BLOCKING 0 PER SHEAR WALL CALLOUT BELOW EXTEND WALL SHEATHING BELOW TO TRUSS BAND AND PROVIDE WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE O OPEN WEB FLOOR TRUSSES WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL �T/PL SCHEDULE [ PER SHEAR WALL CALLOUT BELOW PERiARCH er� SHEAR WALL BELOW PER PLAN CALLOUT - -A - 410.2.12. SHEAR CONNECTION REQUIREMENTS AT OPEN WEB TRUSSES AT EXTERIOR SHEAR WALLS WITH PARALLEL FRAMING. (3) 0.131"X2-1/2" NAILS INTO 2X BLOCKING @ 48" O.C. SHEAR WALL ABOVE PER PLAN CALLOUT SILL PLATE NAILING TO RIM PER SHEAR WALL SCHEDULE T/PEER I O3 FOR SHEAR WALL CALLOUT ABOVE PE•�\ I I" WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE 1 PER SHEAR WALL CALLOUT ABOVE 1 FLOOR SHEATHING PANEL EDGE NAILING INTO BLOCKING PER SHEAR WALL CALLOUT BELOW 1 EXTEND WALL SHEATHING BELOW TO T/LADDER TRUSS AND PROVIDE WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL SCHEDULE O 'LADDER" TYPE OPEN WEB FLOOR TRUSSES AT PERIMETER �r/PL � 2X4 BRACE @ 48" O.C. WITH (3) FACE NAILS TOP AND (3) PER RARCFi TOE NAILS BOT WALL SHEATHING PANEL EDGE NAILING PER SHEAR WALL _SCHEDULE (D PER SHEAR WALL CALLOUT BELOW SHEAR WALL BELOW PER PLAN CALLOUT 411. FORCE TRANSFER AROUND OPENINGS 411.1. WHERE HORIZONTAL STRAPS ARE SHOWN ON THE SHEAR WALL PLAN ACROSS AN OPENING, THE OPENING IS INCORPORATED WITHIN THE SHEAR WALL ASSEMBLY AS A FORCE -TRANSFER AROUND OPENING (FTAO) CONDITION. FRAMING, STRAPPING, AND NAILING REQUIREMENTS FOR FTAO ASSEMBLIES SHALL BE PER THE FORCE -TRANSFER AROUND OPENING DETAILS AS FOLLOWS: 411.1.1. AT OPENINGS WITH CRIPPLE WALLS ABOVE AND BELOW OPENING: i HEADER PER PLAN DOUBLE 2X BLOCKING AT STRAP �f CONTINUOUSLY SHEATHED SHEAR WALL AROUND OPENING PER PLAN SHEAR WALL CALLOUT EXTEND STRAP PAST OPENING AS INDICATED PER PLAN. IF NOT CALLED OUT, MIN 4'-0" OR TO END OF WALL WHICHEVER IS SHORTER. TOP AND BOT, BOTH SIDES OF OPENING PROVIDE SHEAR WALL PANEL EDGE NAILING _ I AT BOTH JACK AND KING STUDS. BOTH SIDES �� �• OF OPENING OPENING PER ARCH DOUBLE 2X BLOCKING AT STRAP DOUBLE SILL PLATE AT STRAP 411.1.2. AT OPENINGS WITH CRIPPLE WALLS ABOVE OPENING ONLY: HEADER PER PLAN DOUBLE 2X BLOCKING AT STRAP CONTINUOUSLY SHEATHED SHEAR WALL AROUND OPENING PER PLAN SHEAR WALL CALLOUT -EXTEND STRAP PAST OPENING AS INDICATED PER PLAN. IF NOT CALLED OUT, MIN 4'-0" OR TO END OF WALL WHICHEVER IS SHORTER. TOP AND BOT, BOTH SIDES OF OPENING _ -PROVIDE SHEAR WALL PANEL EDGE NAILING \\ AT BOTH JACK AND KING STUDS. BOTH SIDES OF OPENING OPENING PER ARCH CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 07/07/2026 9:22:31 AM BY: KELLY TAFT TSBPE: 1-3971 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY F j4, V,v .............................. PATSEVICH I , , 130521 ONA L ENG\� O O Z Z W Z 0 W Z w W z Z2 00W J M m 2: .',I --I O O p1 �O U .--I Ur x z Luz Lu LL- ,_, z Wiz a- Lu O ~ � J rl U JG O Lu 7 F- OL. Oi 00 N Ln N �O rV REVISIONS 0 DATE BY PROJECT NAME 101 CROSS CREEK GARAGE ADDITION PROJECT ADDRESS 101 CROSS CREEK DR GRAPEVINE, TX PROJECT NUMBER S26129 CHECKED BY - AP SHEET DATE - 05/04/2026 SCALE 24X36 SHEET:1/2"=V-0" z _O Ln Lu 0 Lu J LLJ Z Q J LLJ 0 Lu 0 z U 9 m J Q 1 J/ L 2 Ln ALL CHANGES MUST BE APPROVED. SHEAR WALL PLAN NOTES cn ` SW6 � I I I I I I i I � cn I I I 1 1 � I � I I cn I I I I I I SW6 1 I FOR TYPICAL SHEAR WALL INSTALLATION AND STANDARD DETAIL REQUIREMENTS, REFER TO THE GENERAL SHEAR WALL NOTES (GN401) AS FOLLOWS: SHEATHING AND FRAMING MATERIALS - SEC. 402 SHEAR WALL CONSTRUCTION AND NAILING - SEC. 403 HOLDOWNS AND OVERTURNING RESTRAINT - SEC. 404 PORTAL FRAMES - SEC. 405 SPECIAL / PREFABRICATED SHEAR WALL PANELS - SEC. 406 SHEAR WALL SCHEDULE - NOTE 409 STANDARD SHEAR TRANSFER DETAILS - SEC. 410 FORCE TRANSFER AROUND OPENINGS (FTAO) - SEC. 411 SEE ALSO: GENERAL STRUCTURAL NOTES (GN100) AND GENERAL FRAMING NOTES (GN301) FOR ADDITIONAL MATERIAL, FASTENER, AND FRAMING REQUIREMENTS. WHERE SPECIFIC NOTES OR DETAILS ARE SHOWN ON THE PLANS, THOSE SHALL GOVERN. CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 07/07/2026 9:22:36 AM BY: KELLY TAFT TSBPE: 1-3971 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY ALL CHANGES MUST BE APPROVED. ROOF 2ND FLOOR 1ST FLOOR/ FOUNDATION LEVEL KEY ALIAKSEI PATSEVICH .A. .•.130521 `1\��ONAL ENS~ W Q 0 Z z*a o W z w Z W z Z z 00W J M Ql 57 boo �p U u zt� x w � w w � z z > '-' _j 0 Lu o- z w x O x> O w CID (f) Q L CL Q a rl 00 CV u'? N REVISIONS DATE BY PROJECT NAME 101 CROSS CREEK GARAGE ADDITION PROJECT ADDRESS 101 CROSS CREEK DR GRAPEVINE, TX PROJECT NUMBER S26129 CHECKED BY - AP SHEET DATE - 05/04/2026 SCALE 24X36 SHEET: 1/2"=1'-0" z J J Q Q L1J z0 0 a i C!? r LL U w Cf) w LL SHEAR WALL PLAN NOTES Ln s% /l SW6 et SW6 FOR TYPICAL SHEAR WALL INSTALLATION AND STANDARD DETAIL REQUIREMENTS, REFER TO THE GENERAL SHEAR WALL NOTES (GN401) AS FOLLOWS: SHEATHING AND FRAMING MATERIALS — SEC. 402 SHEAR WALL CONSTRUCTION AND NAILING — SEC. 403 HOLDOWNS AND OVERTURNING RESTRAINT — SEC. 404 PORTAL FRAMES — SEC. 405 SPECIAL / PREFABRICATED SHEAR WALL PANELS — SEC. 406 SHEAR WALL SCHEDULE — NOTE 409 STANDARD SHEAR TRANSFER DETAILS — SEC. 410 FORCE TRANSFER AROUND OPENINGS (FTAO) — SEC. 411 SEE ALSO: GENERAL STRUCTURAL NOTES (GN100) AND GENERAL FRAMING NOTES (GN301) FOR ADDITIONAL MATERIAL, FASTENER, AND FRAMING REQUIREMENTS. WHERE SPECIFIC NOTES OR DETAILS ARE SHOWN ON THE PLANS, THOSE SHALL GOVERN. CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 07/07/2026 9:22:41 AM BY: KELLY TAFT TSBPE: 1-3971 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY ALL CHANGES MUST BE APPROVED. all$]] 2ND FLOOR ALIAKSEI PATSEVICH .A. .•.130521 `1\��ONAL ENS~ W Q 0 Z z*a o W z w Z W z Z z 0 0 Lu J M Ql 57 boo �p U u zt� x Lu w Lu� z z > '—' _j 0 Lu o- z w x O x> o Lu CID (f) Q L CL Q a rl 00 CV u') N REVISIONS DATE BY PROJECT NAME 101 CROSS CREEK GARAGE ADDITION PROJECT ADDRESS 101 CROSS CREEK DR GRAPEVINE, TX PROJECT NUMBER S26129 CHECKED BY — AP SHEET DATE — 05/04/2026 1ST FLOOR/ z FOUNDATION p a LEVEL KEY cl� U w 0 SCALE 24X36 SHEET: 1/2"=1'-0" z Q J J Q Q Lu U) rC 0 0 J LL U') z 0 V Lu w cn 5/4/26, 11:55 AM Z4 1 r-� i -=9 .�.a rik "AY'�I L01 r rrq IN,IG_1977.jpeg ° �ILOBet5�6i� �o ;r� CRY OF GRAPEVINE THS PAGE RELEASED FOR CONSTRUCTION Fatlif s CONFLICT WITH THE SMOING CODE OR ZONING ORDINANCE CRY APPROVED PLANS TO BE KEPT ON THE JOB SRE AT ALL nME S. 07/07/2026 9:22:49 AM BY: KELLY TAFT TSBPE: 1-3971 BUILdNG NfPECi10N DM SION: RELEA SE DOES NOT APPLY TO CONSTRUCTION IN EA SMOM OR MOM PWff-C F-WAY ALL CHANGES MUST BE APPROVED. https-//mail.google.corn/mail/u/0/?tab=rm&og b l#inbox?projector=1 1 /1