HomeMy WebLinkAboutSFRA2026-002038SHEET INDEX
SCOPE OF WORK
PAGE # DESCRIPTION
SYSTEM SIZE: 12.71 KW DC, 11.5KW AC
PV-1.0 COVER SHEET
MODULES: (31) HANWHA Q-CELLS: Q.PEAK DUO BLK
ML-G10.C+ 410 (MD06G100A-017)
PV-2.0 SITE PLAN
• RAPID SHUTDOWN: (13) TESLA MID CIRCUIT INTERRUPTER
PV-3.0 LAYOUT
(MCI) ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE
• ENERGY STORAGE SYSTEM W/ INTEGRATED PV INVERTER:
PV-4.0 ELECTRICAL
(1) TESLA: POWERWALL 3 1707000-XX-Y, 13.5KWH, 11.5KW
INVERTER OUTPUT, LITHIUM -ION BATTERY (WEIGHT: 291.2 LB
PV-5.0 SIGNAGE
EACH)
PV-5A SIGNAGE 2
• BACKUP GATEWAY: (1) 200A TESLA POWERWALL CONTROL
PANEL
RACKING: ALPHATRACK TO FRAMING - SNR-DC-00370
RECEIVED: 05/29/2026
26-002038
3318 BRIDLEWOOD DR
SOLAR PANELS
ABBREVIATIONS
VICINITY MAP
A AMPERE
- -
AC ALTERNATING CURRENT
- L
AFC ARC FAULT CIRCUIT INTERUPTER
AZIM AZIMUTH
COMP COMPOSITION
8
DC DIRECT CURRENT
;
(E) EXISTING
ESS ENERGY STORAGE SYSTEM
Hall - Johnson Rd
MSP MAIN SERVICE PANEL
(N) NEW
15
PRE-FAB PRE-FABRICATED4
ood Ur K
PSF POUNDS PER SQUARE FOOT
¢Y
�a
� m
PV PHOTOVOLTAIC
RSD RAPID SHUTDOWN DEVICE
Sprind¢R•¢e DI c`
TL TRANSFORMERLESS
E y
��Qa40r
V VOLTS
g 3 S
W WATTS
s
e
GENERAL NOTES
• ALL WORK SHALL COMPLY WITH 2O21 IRC/IBC/IEBC, ASCE 7-16 & 2018 NDS, MUNICIPAL CODE, AND ALL
MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS.
PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020.
ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020.
PHOTOVOLATIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM
COMPLIES WITH 690.41(A)
MODULES CONFORM TO AND ARE LISTED UNDER UL 61730.
INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.
SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED.
RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY
BOUNDARIES PER NEC 690.12(1).
CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G).
ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT.
11.26 AMPS MODULE SHORT CIRCUIT CURRENT.
17.59 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a) & 690.8 (b)].
THE CAPACITY OF THE STANDALONE SYSTEM SUPPLY SHALL BE EQUAL TO OR GREATER THAN THE LOAD POSED
BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER NEC ARTICLE 710.15(A)
ALL PASS -THROUGH CONDUCTORS MUST COMPLY WITH NEC 312.8
NEC 2020 705.12(B)(3)(3): THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT
DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR.
ALL CHANGES REQUIRE
APPROVAL OF REVISED
PLANS
APPROVED PLANS SHALL BE
KEPT ON JOBSITE AT ALL TIMES
CONSTRUCTION HOURS
7:00 A.M. - 7:00 P.M.
MONDAY - SATURDAY ONLY
NO WORK PERMITTED ON SUNDAY
SEPERATE PLUMBING,
MECHANICAL, ELECTRICAL AND
SIGN PERMITS SHALL BE REQUIRED
GRAI 'ICE._
PLANS HAVE BEEN
REVIEWED & APPROVED BY
A THIRD PARTY
CONTRACTOR
Approved for Construction by:
W. Scott Leavelle (TPI)
6-2-26
CONTRACTOR SHALL CALL FOR INSPECTIONS:
(817) 410-3010
CONTRACTOR REGISTRATION WILL BE
REVOKED UPON PERMIT EXPIRATION.
REV NAME DATE COMMENTS
SLnRLn
28447
-III STATE HIGHWAYa SURE Zap. GRAND PRAIRIE.
n /spso
Pnorvean-sn-wer
der ana cn a,00
CUSTOMER RESIDENCE:
ABBEY DARKO
3318 BRIDLEWOOD DR,
GRAPEVINE, TX, 76051
TEL. (817) 682-2383
APN: 04782968
PROJECT NUMBER:
351 R-318DARK
DESIGNER: (415) 580-6920 ex3
Jean Claude IRADUKUNDA
SHEET
COVER SHEET
REV: A 5/28/2026
PAGE
PV-1.0
SITE PLAN - SCALE - 1/16"=1'-0"
FIRE SETBACKS
(3 TYP)
PL I
�l C MP SE
ROOF PATHWAYS �-
(3' TYP)
(N) ARRAY AR-02
E
NOTE: ROOFTOP MODULE LEVEL RAPID
SHUTDOWN DEVICE INSTALLED PER NEC
690.12
NOTES:
• RESIDENCE CONTAINS ACTIVE FIRE SPRINKLERS.
ARRAY DETAILS:
• TOTAL ROOF SURFACE AREA: 3395 SO FT.
• TOTAL PV ARRAY AREA: 655.2 SO FT.
• PERCENTAGE PV COVERAGE:
(TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE
AREA)' 100 = 19.3%
ARRAY
TRUE
MAG
PV AREA
PITCH
AZIM
AZIM
(SOFT)
AR-01 M.
850
82°
295.90
AR-02 M.
265°
262°
84.54
AR-03 26'
175°
172'
274.76
(E) RESIDENCE
D
- (N) ARRAY AR-01
r (N) ARRAY AR-03
INV AC
f"- o
(E) DRIVEWAY
BRIDLEWOOD OR
Approved for Construction by:
W. Scott Leavelle (TPI)
6-2-26
LEGEND SCALE: NTS
NoreNOT ALLITEMSINLEGEND
wI'LLAIN SITE PLAN
RDS
®
REMOTE DISCONNECT
SWITCH
INV
INVERTER(S)
BPPPEAR
BACKUP LOADS PANEL
❑MICROGRID
MD
INTERCONNECT DEVICE
SOLAR
INTERIOR EQUIPMENT
MODULES
L SHOWN AS DASHED
SE SERVICE ENTRANCE
AC
AC DISCONNECT(S)
GP
GENERATION PANEL
+1 F
BATTERY
MA
METER ADAPTER
J
APB FRANKLBOX IN
P
MP
MAIN PANEL
0
DC DISCONNECT(S)
LC
PV LOAD CENTER
ENERGY SYSTEM (E S)
APT
MAC CONTROMETER L ER ER
CB IO COMBINER BOX SNR MOUNT
SP
SUB -PANEL
pM
DEDICATED PV METER
SNR MOUNT & SKIRT
SLnRLn
28447
-II STATE HIGHWAY -I SUR II GRAND PNAIRIE
CUSTOMER RESIDENCE:
ABBEY DARKO
3318 BRIDLEWOOD DR,
GRAPEVINE, TX, 76051
TEL. (817) 682-2383
APN: 04782968
PROJECT NUMBER:
351 R-318DARK
DESIGNER: (415) 580-6920 ex3
Jean Claude IRADUKUNDA
SHEET
SITE PLAN
REV: A 5/28/2026
PAGE
PV-2.0
ROOF INFO
Name
Type
Height
AR-01
COMP SHINGLE -
1-STORY
ALPHATRACK
AR-02
COMP SHINGLE -
1-STORY
ALPHATRACK
AR-03
COMP SHINGLE -
1-STORY
ALPHATRACK
D1 - AR-01
- SCALE: 1/16" =
V-0"
AZIM: 85°
PITCH: 34°
D2 - AR-02 - SCALE: 1/16" = V-0"
AZIM: 265°
PITCH: 34°
FRAMING INFO
Type
Max
OC
Detail
Span
Spacing
2X6 RAFTERS
12'-11"
24"
ALPHATRACK TO FRAMING - SNR-DC-00370
2X6 RAFTERS
11'-8"
24"
ALPHATRACK TO FRAMING - SNR-DC-00370
2X6 RAFTERS
14'-2"
24"
ALPHATRACK TO FRAMING - SNR-DC-00370
T-10"
2' 4"
- - 6'-2"
Li
"/
5'-1 /
OD
6'
TYP# f
31511
3'-_11"
n
24'-1"
ATTACHMENT INFORMATION
DESIGN CRITERIA
Max Landscape Max Landscape
Max Portrait
Max Portrait
Configuration
MAX DISTRIBUTED LOAD: 3 PSF
OC Spacing Overhang
OC Spacing
Overhang
SNOW LOAD: 5 PSF
WIND SPEED:
6'-0" 2'-4"
4'-0"
2'-0"
STACKED
115 MPH 3-SEC GUST.
FASTENERS:
(1) 5/16" DIA S.S. LAG SCREW:
6'-0" 2' 4"
4'-0"
2' 0"
STACKED
2.5" MIN EMBEDMENT INTO
FRAMING
6-0" 2'4"
4'-0"
2'-0"
STACKED
Approved for Construction by:
W. Scott Leavelle (TPI)
6-2-26
D3 - AR-03 - SCALE: 1/16" = V-0"
AZIM: 175°
PITCH: 26°
-11'-3" - 12'-5" — 3' - T-3—/{�-#\ - 2'
I/ `I
15'-5"
- I 4 2N
6' TYP # fi 6' 13" 8" J
6'-11" 6' TYP 3'-6"
4'21" I 4'-5"
— 31-411 #— — �1'-6"
STRUCTURAL NOTES AND OVERHANG REDUCED WITHIN THE 12" (48" FOR TILT KITS) BOUNDARY REGION
• INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES ONLY AS FOLLOWS:
OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. •• ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50%.
•• ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE
• IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" (48" FOR TILT KITS) BOUNDARY REGION OF ATTACHMENT SPACING INDICATED ON PLANS.
ANY ROOF PLANE EDGES (EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED
OF rrxgi1,
� I
i JAMES htpTTHEW ..IALSH
i
0
S "
DigbH, Slgnetl QWSI 92026
F-19352
28447
? N STATE HIGHWAYS SUHE200. -ND PNAINIE
CUSTOMER RESIDENCE:
ABBEY DARKO
3318 BRIDLEWOOD DR,
GRAPEVINE, TX, 76051
TEL. (817)682-2383
APN: 04782968
PROJECT NUMBER:
351 R-318DARK
DESIGNER: (415) 580-6920 ex3
Jean Claude IRADUKUNDA
SHEET
LAYOUT
REV: A 5/28/2026
PAGE
PV-3.0
EXISTING 200A BACKUP LOAD
PANEL WITH 2O0A MAIN BREAKER
4A20D
Surge protector BACKUP(
required in this
enclosure
NEW 200A
METER NUMBER:139362131LG BACKUP GATEWAY
- GATEWAY 3
(1841000-X1-Y)
WITH 2O0A
MAIN BREAKER
(N)INTERNAL P B
WITH(1)60A PV- BREAKER
Grounds and Neutrals
shall be bonded
together in this
enclosure
Approved for Construction by:
W. Scott Leavelle (TPI)
6-2-26
Grounds and Neutrals shall
be separated in these
enclosures
(N)LOCKABIE (N) CKABLE
BLADE TYPE B TYPE
AC DISCONNECT AC DIS .ONNECT INVERTER_ TESLA 11500
WATTSPOWERWALL3
A 1707000-XX-Y,
ENERGY STORAGE.
TESTA POWERWALL 3 31 HANWHA O-CELLS
1707000-XX-Y (24OV) O.PEAK DUO BLK ML-G10.C+ 410 (MDO6G100A-017)
3 3 3 2 1 STRING 1 WITH 7 MODULES
WITH 3 MCI COUNT
_ STRING 2 WITH 7 MODULES
WITH 3 MCI COUNT
` STRING 3 WITH 7 MODULES
Y J-BOX WITH 3 MCI COUNT
S(}U/1FE'N.-/ S D STRING 4 WITH 4 MODULES
DU222RB DU R WITH 2 MCI COUNT
3R, 60A, 2P 3R, 60A, 2P /U T STRING 5 WITH 6 MODULES
120240VAC 1201240VAC WITH 2 MCI COUNT, MODULE LEVEL RAPID SHUTDOWN DEVICES
LOAD RATED OC DISCONNECT
WITH AFCI RAPID SHUTDOWN
COMPLIANT
POINT OF INTERCONNECTION: NEC 2020 705.12(6)(3)(3), INTERCEPT METER
EQUIPMENT CHARACTERISTICS INCLUDED IN SPEC SHEETS
NOTE: TOTAL SYSTEM BACKFEED = 60.OA USED FOR INTERCONNECTION CALCULATIONS
CONDUIT SCHEDULE
TAG
CIRCUIT DESCRIPTION
CONDUCTOR
NEUTRAL
1
Inverter Input
(10) 10 AWG (PV WIRE)
N/A
2
Inverter Input
(10) 10 AWG
N/A
THHN/THWN-2
3
Inverter Output
(2) 6 AWG
(1) 6 AWG
THHNtTHWN-2
THHN/THWN-2
4
Backup Panel Feeder
(2) 210 AWG
(1) 2/0 AWG
THHN/THWN-2
THHN/THWN-2
5
Service Feeder
(2) 2/0 AWG
THHN(THWN-2
(1) 210 AWG
THHN/THWN-2
GROUND CONDUIT
10 AWG (BARE) Open Air
10 AWG THHN/THWN-2 1" EMT
8 AWG THHN/THWN-2 3/4"EMT
6 AWG THHN/THWN-2 2" EMT
NONE 1-1/2"EMT
swnun
I•%m
? N STATE 1IGHWAY3 SURE200. GRAND PRAIRIE
CUSTOMER RESIDENCE:
ABBEY DARKO
3318 BRIDLEWOOD DR,
GRAPEVINE, TX, 76051
TEL. (817)682-2383
APN: 04782968
PROJECT NUMBER:
351 R-318DARK
DESIGNER: (415) 580-6920 ex3
Jean Claude IRADUKUNDA
SHEET
ELECTRICAL
REV: A 5/28/2026
PAGE
PV-4.0
�l WARNING
ELECTRICAL SHOCK HAZARD
TERMINALS ON LINE AND LOAD
SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
LABEL LOCATION:
INVERTER(S), AC/DC DISCONNECT(S),
AC COMBINER PANEL (IF APPLICABLE).
PER CODE(S): NEC 2020: 690A3(B)
WARNING
I THREE POWER SUPPLY
SOURCES: UTILITY GRID.
BATTERY AND PV SOLAR
ELECTRIC SYSTEM
LABEL LOCATION:
UTILITY SERVICE METER AND MAIN
SERVICE PANEL.
PER CODE(S): NEC 2020: 705.12(C)
WARNING
POWER SOURCE OUTPUT CONNECTION
DO NOT RELOCATE THIS
OVERCURRENT DEVICE 1
LABEL LOCATION:
ADJACENT TO PV BREAKER AND ESS
OCPD (IF APPLICABLE).
PER CODE(S): NEC 2020: 705-12(6)(3X2)
6 0 WARNING
THIS EQUIPMENT FED BY
MULTIPLE SOURCES. TOTAL
RATING OF ALL OVERCURRENT
DEVICES EXCLUDING MAIN
SUPPLY OVERCURRENT DEVICE
SHALL NOT EXCEED AMPACITY OF
BUSBAR
LABEL LOCATION:
PV LOAD CENTER (IF APPLICABLE) AND
ANY PANEL THAT UTILIZES "THE SUM
OF BREAKERS RULE".
PER CODE(S): NEC 2020: 705.12 (6)(3)(3)
INVERTER 1PHOTOVOLTAIC DC DISCONNECT OTES AN J� S F, F C�T`�]('{
.JSIGNS AND LABC�LS Mff ttET THE REQUIREMENTS OF THE NEC 2020 ARTICLE
110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR
IF REQUESTED BY THE LOCAL AHJ.
VOLTAGEMAXIMUM SYSTEM 550VDC SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
WORDS, COLORS AND SYMBOLS.
LABEL LOCATION: • LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING
INVERTER(S), DC DISCONNECT(S)_ METHOD AND SHALL NOT BE HAND WRITTEN.
PER CODE(S): NEC 2020: 690,53 • LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
INVOLVED.
• SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY
SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.
• DO NOT COVER EXISTING MANUFACTURER LABELS.
Approved for Construction by
LABEL LOCATION: W. Scott Leavelle JR)
INSTALLED WITHIN T OF RAPID SHUT DOWN 6-2-26
SWITCH PER CODE(S): NEC 2020: 69e56(Cx2),
CEC 2022: 690-56(C)(2), IFC 2015: 1204.53
• • • ZCAUTION
LABEL LOCATION: ENERGY STORAGE SYSTEM
INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
AT EACH TURN, ABOVE AND BELOW PENETRATIONS,
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
PER CODE(S): NEC 2020: 690.31(D)(2)
Alj � LO 10
AC ISC IEC 5), PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION_
PER CODE(S): NEC 2020: 690.54
PREMISES WIRING MAY REMAIN
ENERGIZED AFTER LOSS OF
UTILITY POWER i SU ,^{ ■L411
LABEL LOCATION:
INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE).
4" PER CODE(S): NEC 2020: 706.15(C)
SOLAR PV SYSTEM EQUIPPED —N s
nm ware Nicnwav wo. suite mo. caarvo P-illeu nos
WITH RAPID SHUTDOWN
I—NE8- 72-0091
A,," --
CUSTOMER
TOMER RESIDENCE:
ABBEY DARKO
3318 BRIDLEWOOD DR,
TURN RAPID SHUTDOWN ENERGY STORAGEDISCODISCONNEIC GRAPEVINE, TX, 76051
SWITCH TO THE "OFF" SOLAR i2orz4o TEL. (817) 682-2383
ELECTRIC PV APN: 04782968
POSITION TO SHUT DOWN PV PANELS PROJECT NUMBER:
SYSTEM AND REDUCE SHOCK 351R-318DARK
HAZARD IN THE ARRAY.
LABEL LOCATION: DESIGNER: (415)580-6920ex3
ENERGY STORAGE SYSTEM Jean Claude IRADUKUNDA
PER CODE(S): NEC 2020: 706.15(C) SHEET
LABEL LOCATION: SIG NAG E
ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
REV: A 5/28/2026
ARE CONNECTED
PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C) PAGE
PV-5.0
CAUTION:
MULTIPLE SOURCES OF POWER
ESS DISCONNECT
LZO
PV SYSTEM DISCONNECT
-SERVICE ENTRANCE AND
MAIN PANEL
3318 BRIDLEWOOD DR, GRAPEVINE, TX, 76051
PER CODE(S) : NEC 2020 705.10,710.10
LABELING FORMAT
LABELS SHALL BE RED PLASTIC MATERIAL WITH ENGRAVED WHITE LETTERS
MADE OF DURABLE ADHESIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR
THE ENVIRONMENT. LETTERS SHALL BE MINIMUM 3/8" IN SIZE.
Approved for Construction by:
W. Scott Leavelle (TPI)
6-2-26
SLnRLn
28447
2990 N. STATE NIGHWRV 3fi0. StME200. GpAHD PgAIP�
TX ]5050
CUSTOMER RESIDENCE:
ABBEY DARKO
3318 BRIDLEWOOD DR,
GRAPEVINE, TX, 76051
TEL. (817) 682-2383
APN: 04782968
PROJECT NUMBER:
351 R-318DARK
DESIGNER: (415) 580-6920 ex3
Jean Claude IRADUKUNDA
SHEET
SIGNAGE 2
REV: A 5/28/2026
PAGE
PV-5.1
5/28/2028 08'.50 PM
Subject Structural Certification for Proposed Residential Solar Installation.
Job Number 351R-318DARK, Rei
Client ABBEY DARKO
Address'. 3318 Brldlewood Dr, Grapevine, TX 78051
Attnl To Vvhom It May Concern
X co 6pu III
•..1/ F-093M
JAMES MATfHEW WALSH
.q ....140542
Eep. 12,31MUS
plgllelly Signed 0n'. 05292028
Astra v2.2OO
CAT 1
Afield observation ofthe existing structure at the address Indicated above was performed. Structural evaluation ofthe loading was based on
the site observations and the design criteria listed below,
Design Crltedal
• 2021 IRC/IBC/IEBC, ASCE 7-18 & 2018 NDS
• Basic (Category II)Wnd Speed V=115 mph, Exposure B
• Ground Snow Load = 5 psf
Based on this evaluation, I certify that the alteration to the existing structure by the installation ofthe PV system meets the requirements ofthe
applicable Sell and/or new building code provisions referenced above, Additionally, I certify that the PV module assembly including all
attachments supporting It have been reviewed to be In accordance with the manufacturers specifications,
Results
Summary (Hardware
Check Includes Uplift Check on AttachmenblFastener, Structure Check
Considers Main
Structure)
Orientation
Attachment Spacinguo ntllever
Configuration
Mae OCR
Result
AR41
Landscape
Portred
72128
48124
Stacketl
Stacketl
32%
46%
Peee
Paee
Roofing Material
Pitch
Structure Check
Comp Shingle
34-
Paee
Orientation
Attachment SpacinglCantilever
Configuration
Max OCR
Result
AR42
Lantlscape
Portrait
72/28
48124
Stacked
Stacked
32%
46%
Pass
Pass
Roofing Material
Pitch
Structure Check
Comp Shingle
34-
Pass
Orientation
Attachment SpacinglCantilevar
Configuration
Max OCR
Result
AR43
Lantlscape
Po a
72128
48124
Specked
Stacked
32%
47%
Paee
Pa..
Roofing Material
Pitch
Structure Check
Comp Shingle
28°
Peee
Approved for Construction by:
W. Scott Leavelle JR)
6-2-26
225 Bush St. Suite 1400 San Francisco, CA 94104
Article 220 - Service Feeder calculation for (address)
3318 Bridlewood or Grapevine TX USA 76051
Section 220.83 Existinq Dwellinq Unit
Part #1 - Section 220.83(A)(1) Generatl Liqhtinq/Receptacles (a? 3 VAyer gQ ft:
Building Square Footage VA (wafts)
House 2424 7272
Total for Part #1:
Part #2 - Section 220.83(A)(2),(4) Appliances and Dedicated Circuits
Dedicated Circuit
Size in VA Dedicated Circuit
Dryer
5760
Oven
5760
Range
5760
Appliance Circuit 1
1500
Appliance Circuit 2
1500
Laundry
1500
N/A
N/A
N/A
N/A
N/A Total for Part #
Total VA from Parts #1 and #2 combined:
Total VA 29052
Job Code
351 R-318DARK
Amps
30.3
Amps Box A (VAI 1
30.3 I 7272
Size in VA
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Amps Box B (VA)
2: 90.75 I 21780
Box A + Box B = 29052
First 8000 VA @ 100 %
8000 Remaining VA @ 40
Remaining VA=
21052 21052 x40%=
8420.8
VA
Adding First 8,000 VA
8000
VA
Total VA for Gen.
Lights/Recep, Appliances & Dedicated circuits:
16420.8
VA
Total AMP for Gen.
Lights/Recep, Appliances & Dedicated circuits:
68.42
Amps
Part #3 - Section 220.83(N Heatir)Q and A/C Loads:
"Combine the larger loads of either the Heating or the A/C loads togther
100 % of all the Heating or A/C loads in VA: 7680 VA
100 % of all the Heating or A/C loads in Amps: 32 A
Totals from all Parts
VA Volts Amps
Approved for Construction by: Parts #1 & #2 16420.8 240 68.42
W. Scott Leavelle (TPI) Part#3 7680 240 32
6-2-26 Total VA for all Parts: 24100.8
Totals Service/Feeder Load F100.42
Panel 1 of 1
Bus Rating: 200
Main Rating: 200
Panel % of Sq.Ft: 100%
Itemized House and 240V Loads for Panel: (VA)
A/C Unit -240V 7680
Dryer 5760
Oven 5760
Range 5760
Not Fed by other panels
Load Calc: (This Panel) 100.42
Total Load Calc:
Panel % of Total VA: 100%
Appliance Circuit 1 1500
Appliance Circuit 2 1500
Laundry 1500
Approved for Construction by:
W. Scott Leavelle JPI)
6-2-26
OPEAK DUO BLK
IVIL-G10+ SERIES ocell;
Approved for Construction by:
390-410Wp 1132Cells W. Scott Leavelle (TPI)
20.9% Maximum Module Efficiency 6-2-26
MODEL Q.PEAK DUO BLK ML-G10+it
The ideal solution for:
Rooftop arrays on
residential buildings
Breaking the 20 % efficiency barrier
1;iL� �L�LL Q.ANTUM DUO Z Technology with zero gap cell layout
boosts module efficiency up to 20.9%.
25 A reliable investment
La Inclusive 25-year product warranty and 25-year linear
Warranty performance warranty'.
Enduring high performance
Long-term yield security with Anti LeTID Technology,
ocells Anti PID Technologyz and Hot -Spot Protect.
Extreme weather rating
High-tech aluminium alloy frame, certified for
high snow (5400Pa) and wind loads (4000Pa).
�
I . Innovative all-weather technology
l2/ Optimal yields, whatever the weather with excellent low -light
and temperature behaviour,
n The most thorough testing
�/\•J( programme in the industry
Ocells is the first solar module manufacturer to pass the
most comprehensive quality programme in the Industry: The
new "Quality Controlled PW ofthe independent certification
Institute TUV Rheinland.
See cats sneer or rear for further Information.
' APT test cond*sons according to ;ECITS 628041:7015, metnoc A ;-1500 V, 96 h
cm_wi�aw 2
w zou h
Q.PEAK DUO BLK ML-G10+ SERIES
■ Mechanical Specification
Format
74.0in x 41.11n x 1.26in (Including from a)
0879mm x 1045mm x 32 mm)
Weight
48.51bs (22.Okg)
Front Cover
0,13 In (3.2 mm) thermally pre-stressea glass
with anti -reflection technology
Back Cover
Transparent composite film with black grid
Frame
Black anodised aluminium
Cell
6 x 22 monocrystalllne O.ANTUM solar half cells
Junction box
2.09-3.98in x 1,26-2.36in x 0.59-0.7tin
(53-101mm x 32-60mm x 15-18mm), IP67, with bypass diodes
^ nen,•,-1
�at.a f:W mml -mot '66'?e�+=Tm;
:>ta•,roomra
er Mam+a
Ol+l' nee m'1
-a-I-❑ +n Ol'resG rnQ
s. p'emrenexs
I a rro„ero uwonaLk a�
Cable 4mm' Solar cable: (-) z72.041n 0830mm), (-) z72.D4in (1830mm)
Connector Staubli VC4; IP68
pYe',ilsmml I-�Jala sswm;
■ Electrical Characteristics
POWER CLASS 390 395 400 40S 410
MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC (POWER TOLERANCE-5W/-OW)
BSTC' BSTC' BSTC' BSTC' BSTC'
Power at MPP' PM„ [W] 390 426,6 395 432.1 400 4375 405 443.0 410 448.5
Short Circuit Current' Isc (A] 11.01 12.05 11.04 12.08 11.07 12.11 11.10 12.15 11.13 12.18
E
E
Open Circuit Voltage' Vcc IV] 45.49 45.65 45.52 45.68 45.55 45.72 45.59 45.75 45.62 45.79
Current at MPP Iv„ [A] 10.39 11.37 10.45 11.43 10.50 11.49 10.56 11.55 10.61 11.61
f
Voltage at MPP Vv- IV] 37.54 37.53 37.91 37.81 38.09 38.08 38.36 38.35 38.63 38.62
Efficiency' n (%] z19.9 2:20.1 2!20.4 z20,6 z20.9
Blfadallty of Pwa and IX 70% t10% - Blfadallty given for rear side irradiation on top of STC 1Yront side) - According to IEC 60904-1-2according to IEC 60904-3
' Measurement tolerances P,u t3%; lu, Voc t5% at STC:1000W/m';'at BSTC: 1000 W/m' + tp x 135 W/m', tp = 70% 110%, 25t2 °C, AM 1.5 according to IEC 60904-3
MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2
Power at MPP Prus, [W] 292.6 296.3 300.1 303.8 307.6
E Short Circuit Current Is„ [A] 8.87 8.89 8.92 8.94 8.97
E Open Circuit Voltage Vcc IV] 42.90 42.93 42.96 42.99 43.03
c
i Current at MPP Iv. [A] 8.16 8.21 8.26 8.31 8.36
Voltage at MPP Vv„ IV] 35.86 36.10 36.33 36.57 36.80
'Measurement tole,ances PN", 13%; leC; Vcc t5% at STC: 1000 W/m2, 25 t2 °C. AM 1.5 according to IEC 60904-3 - 'BOO W/m', \ V OT, soectrum AM 1.5
Ocells PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE
At least 98%of nominal power -' u
during flat year. Thereafter max. iio
ss ----- 0.5% degradation per year. At
least 93.5%of nominal power wo
3 up to 10 years. At least 86% of
nominal power upto 25 years.
of 4
All data within measurement � b
tolerances. Full warranties In
accordance with the warranty
sp terms of the Ocells sales p
o as '0 rs to organisation of your respective 200 sne eao am woo
YEARS country. IRRADIANCEIWIn,j
•Stardeld corms of guarantee for the 51xy companies wet, the
higtlWt pnx1 ctlon camclly In 2021(February 2029 Typcalmotnunwunderlowirratllance cor�ltbns In
comparison
to o STTCCconditions (25°C, f000 W+m').
TEMPERATURE COEFFICIENTS
Temperature Coefficient of IY a %/I -004 Temperature Coefficient of Vpc (3 [%/Ki -0.27
Temperature Coefficient of Pu„ y [%/K] -0.34 Nominal Module Operating Temperature NMOT rF] 109 t5.4
(43 z 3 °C)
■ Properties for System Design
Maximum System Voltage Vers V] 1000 0EQ11000 NL) PV module classification Class II
Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2
Max. Design Load, Push/PulF [los/ft2] 75 (3600 Pa)/55 (266OPa) Permitted Module Temperature -40°F up to -185°F
Max. Test Load, Push/Pull' (10S/ft2] 113(540OPa)/84(4000Pa) "Continuous Duty (-40-Cupto+85°C)
' See Ins:allation Manua
■ Qualifications and Certificates
UL 61730, CE-compliant,
Quality Controlled PV - TUV Rheinland,
IEC 61215:2016, IEC 61730:2016,
U.S. Patent No. 9,893,215 (solar cells),
c 1 us l\
Approved for Construction by:
W. Scott Leavelle JR)
6-2-26
Ocells pursues minimizing paper output In consideration of the global environment.
Note; Installation Irstructbrs must be followed. confect our technical aentIm for funhar Information on approved Installation of the pn iMt. ��' I
P.-h. 0 CELLS Amenca Inc. 400 spectrum Center 00ve, Sulm 1400. Irvine, CA 92618, USA I TEL -1949 748 59 961 EMAIL hgc.1mulry"cell-M I W Ee w,wv.ocells-nn
Powerwall 3
Power Everything
Powerwall 3 is a fully integrated solar and battery system, designed to accelerate the transition to sustainable energy. Customers
can receive whole home backup, cost savings, and energy independence by producing and consuming their own energy while
participating In grid services. Once installed, customers can manage their system using the Tesla App to customize system
behavior to meet their energy goals.
Powerwall3 achieves this by supporting up to 20 kW DC of solar and providing 11.5 kW AC of continuous power per unit. It has
the ability to start heavy loads up to 185 A LRA, meaning a single unit can support the power needs of most homes. Powerwall 3
is designed for mass production, fast and efficient installations, easy system expansion, and simple connection to any electrical
service.
ri
Battery shall be
supported to the
structure. Battery shall
not be supported by
brick.
Battery installation per
manufacturer specs.
Approved for Construction by:
W. Scott Leavelle (TPI)
6-2-26
2024
Approved for Construction by:
Powerwall 3 Technical Specifications W. Scott Leavelle (TPI)
6-2-26
System Technical Model Number 1707000-xx-y
Specifications Nominal Grid Voltage (Input & Output) 120/240 VAC
Grid Type Split phase
Frequency
80 Hz
Overcurrent Protection Device
80A
Solar to Battery to Home/Grid Efficiency
89%12
Solar to Home/Grid Efficiency
97.5%'
Supported Islanding Devices
Gateway 3, Backup Switch, Backup Gateway 2
Connectivity
Wi-Fi (2A and 5 GHz), Dual -port switched Ethernet,
Cellular (LTE/40^)
Hardware Interface
Dry contact relay, Rapid Shutdown (RED) certified switch
and 2-pin connector, RS-485 for meters
AC Metering
Revenue Grade (+/- 0.5%)
Protections
Integrated arc fault circuit interrupter (AFCI), Isolation
Monitor Interrupter (IMI), PV Rapid Shutdown (RED) using
Teals Mid -Circuit Interrupters
Customer Interface
Tests Mobile ADD
Solar Technical Maximum Solar STC Input
Specifications Withstand Voltage
PV DC Input Voltage Range
PV DC MPPT Voltage Range
MPPTs
Maximum Current per MPPT (Imp)
Maximum Short Circuit Current per MPPT (I
Battery Technical
Specifications
20V
Nominal Battery Energy
Maximum Continuous Discharge Power
Maximum Continuous Charge Power
Output Power Factor Rating
Maximum Continuous Current
Maximum Output Fault Current
Load Start Capability (1 s)
Power Scalability
20 kW
600 V DC
60 — 550 V DC
60 — 480 V DC
6
13 A'
15 A'
13.5 kWh AC'
11.5 kW AC
5 kW AC
0 -1 (Grid Code configurable)
48 A
10 kA
185 A LRA
Up to 4 Powerwall3 units supported
'Typical solar shifting use case
'Values provided for 25QC (77°E), at beginning of life 3.3 kW charge/discharge power
'Tested using CEC weighted efficiency methodology.
41he customer Is expected to provide Internet connectivity for Powerwall3; cellular should not be used as the primary mode of
connectivity Cellular connectivity subject to network operator service coverage and signal strength
' Where the DC Input current exceeds the MPPT rating, a jumper can be used to combine two MPPTs Into a single input to
Intake DID current up to 26 A lap / 30 A Is,
Powerwall3 Datasheet 2
Powerwall 3 Technical Specifications
Environmental
Operating Temperature
—20°C to 50°C (-4°F to 122°F) a
Specifications
Operating Humidity(RH)
Up to 100%,condensing
Storage Temperature
—20°C to 30°C (-4°F to 86°F), up to 95% RIP,
non -
condensing, State of Energy (SOE): 25%initial
Maximum Elevation
3000 in (9843 ft)
Environment
Indoor and outdoor rated
Enclosure Rating
NEMA 3R
Ingress Rating
IP67 (Battery & Power Electronics)
IP45 (Wiring Compartment)
Pollution Rating
PD3
Operating Noise @ 1 m
<50 db(A) typical
<62 db(A) maximum
° Performance may be de -rated at operating temperatures
above 40°C (104°1`).
Compliance
Certifications
UL 1642, UL 1699B, UL 1741, UL 1741 SA, UL 1741 SB, UL
Information
1741 PCS, UL 3741, UL 1973, UL 1998, UL 9540,
IEEE 1547-
2018, IEEE 1547.1, UN 38.3
Grid Connection
United States
Emissions
FCC Part 15 Class B
Environmental
RoHS Directive 2011/65/EU
Seismic
AC156, IEEE 693-2005 (high)
Fire Testing
Meets the unit level performance criteria
of UL 9540A
Mechanical
Dimensions
1099 x 609 x193 man (43.25 x 24 x 76 in)
Specifications
Weight
130 kg (287Is)
Mounting Options
Floor or wall mount
Battery shall be
o°
supported to the
0-!
structure. Battery shall
0 I�
not be supported by
brick.
1099 arm
Approved for Construction by:
W. Scott Leavelle (TPI)
6-2-26
609 man
�-mm-�
20N
Powerwdl 3 Datasheet
3
Solar Shutdown Device Technical Specifications
The Solar Shutdown Device is a Mid -Circuit Interrupter (MCI) and is part of the PV system rapid shutdown (RSD) function in
accordance with Article 690 of the applicable NEC. When paired with Powerwall 3, solar array shutdown Is Initiated by any loss
of AC power.
Electrical Model MCH1 MCI-2
Specifications Nominal Input DC Current Rating(1,,) 13A 13A
Maximum Input Short Circuit Current (I.) 19 A
Maximum System Voltage(PVHCS) 600V DC
7 Maximum System Voltage is limited by Powerwall to 600 V DC.
17A
1000 V DC7
RSD Module
Maximum Number of Devices per String
5
5
Performance
Control
Power Line Excitation
Power Line Excitation
Passive State
Normally Open
Normally Open
Maximum Power Consumption
7 W
7 W
Warranty
25 years
25 years
Environmental
Operating Temperature
-40°C to 50°C
-45°C to 70°C
Specifications
(-40oF to 122°F)
(-49°F to 158°F)
Storage Temperature
—300Cto701C
—30°C to 70°C
(-22°Fto158°F)
(-22°F to 158°F)
Enclosure Rating
NEMA4X/IP65
NEMA 4X/IP65
Mechanical
Electrical Connections
MC4 Connector
MC4 Connector
Specifications
Housing
Plastic
Plastic
Dimensions
125 x150 x 22 man
173 x45 x 22 man
(5 x6 x1 in)
(6.8 x 1.8 x1 in)
Weight
350 g (0.77lb)
120 g (0.26 lb)
Mounting Options
ZEP Home Run Clip
Wire Clip
M4 Screw (#10)
MB Bolt (5/16")
Nail / Wood screw
Compliance Certifications
Information
RSD Initiation Method
UL 3741 PV Hazard Control
(and PVRSA) Compatibility
See Powerwall 3 Installation Manual
ILL 1741 PVRSE, ILL 3741,
PVRSA (Photovoltaic Rapid Shutdown Array)
External System Shutdown Switch or
Powerwall3 Enable Switch
Approved for Construction by:
W. Scott Leavelle (TPI)
6-2-26
20N 4
Gateway 3
Teals Gateway 3 controls connection to the grid in a Powerwall system, automatically detecting outages and providing seamless
transition to backup power. It provides energy monitoring that is used by Powerwall for solar self -consumption, time -based
control, and backup operation.
Performance Model Number 1841000-01-y AC Meter Revenue accurate (+/- 0.5%)
Specifications Nominal Grid Voltage 1201240 V AC Communication CAN
Grid Configuration Split phase User Interface Tesla Apia
Grid Frequency 60 Hz Backup Transition Automatic disconnect for
seamless backup
Continuous Current 200 A
Rating Overcurrent 100-200A
Protection Device Service entrance rated
Maximum Supply Short 22 kA with Square D or Eaton CSR, BWH, or BW, or
Circuit Current Eaton main breaker
25 kA with Eaton main Square D OOM breakers
breakers Internal Panelboard 200 A
IEC Protective Class Class I 8-space/16 circuit breakers
Eaton BR, Siemens OP, or
Overvoltage Category Category IV Square D HOM breakers rated
to 10-125A
e Only Eaton CSR or 8W H main breakers are 25 kA rated.
Warranty 10 years
Environmental Operating Temperature -20°C to 50oC(- olio 1227)
Specifications Operating Humidity(RH) Up to 100%,condensing
Maximum Elevation 3000 m (9843 ft)
Environment Indoor and outdoor rated
Enclosure Type NEMA 3R
Compliance Certifications UL 67, UL 869A, UL 916, UL 1741 PCS,
Information CSA 22.2107.1, CSA 22.2 29
Emissions FCC Part 15, ICES 003
Mechanical Dimensions 660 x411 x149 mm
Specifications (26 x 16 x 6 in)
Weight 16.3 kg(36 lb)
Mounting options Wall mount
660
men
Approved for Construction by:
W. Scott Leavelle (TPI)
6-2-26
� —411 mm1 �149-a•
mm
20N Powerwoi 3nam:nesc
Backup Switch
The Teals Backup Switch controls connection to the grid in a Powerwall system, and can be easily installed behind the utility
meter or in a standalone meter panel downstream of the utility meter.
The Backup Switch automatically detects grid outages, providing a seamless transition to backup power. It communicates
directly with Powerwall, allowing home energy usage monitoring from any mobile device with the Teals app.
Performance Model Number 1624171-xx-y
Specifications Continuous Load Rating 200 A, 1201240 V split phase
Maximum Supply Short Circuit Current 22 kA with breakere
Communication CAN
AC Meter Revenue accurate (+1- 0.5%)
Expected Service Life 21 years
Warranty 10years
' Breaker maximum supply short circuit current rating must be equal to or greater than the available fault current.
Environmental Operating Temperature
Specifications Storage Temperature
Enclosure Rating
Pollution Rating
Compliance Safety Standards
Information Emissions
—40°C to 50oC (-40oF to 122°F)
—40°C to 85°C (-40°F to 185°F)
NEMA 313
PD3
USA: UL 414, UL 414 SB, UL 2735, UL 916, CA Prop 65
FCC, ICES
Mechanical Dimensions
176 x 205 x 74 men(6.9 x 8.1 x 2.9 in)
Specifications Weight
2.81le
Meter and Socket Compatibility
ANSI Type 2S, ringless or ring type
External Service Interface
Contactor manual overnde10
Reset button
Conduit Compatibility
1/2-inch NPT
'° Manually overrides the contactor position during
a service event
Approved for Construction b,,
W. Scott Leavelle (TPI)
6-2-26
20N Powerwall 3 Data:heet 6
Backup Gateway 2
Backup Gateway 2 controls connection to the grld when paired with Powerwall3, automatically detecting outages and providing
seamless transition to backup power. Backup Gateway 2 also provides energy metering for solar self -consumption, time -based
control, and backup operation.
In this system configuration, Powerwall 3 acts as the Site Controller, with the Backup Gateway 2 Site Controller disabled.
Performance Model Number
1232100-xx-y
Specifications AC Voltage (Nominal)
120/240 V
Feed -in Type
Split phase
Grid Frequency
60 Hz
Currant Rating
2DOA
Maximum Supply Short
10 kA11
Circuit Current
Overcurrent Protection
100-200 A, Service
Device
entrance rated-
Overvoltage Category
Category IV
Internal Primary
Revenue accurate
AC Meter
(+/-0.2%)
Internal Auxiliary
Revenue accurate
AC Meter
(+/-2%)
Primary Connectivity
Ethernet, Wi-Fi
Secondary Connectivity
Cellular (3G, LTE/40)'a
User Interface Tesla Apia
Operating Modea Support for solar self -
consumption, time -based
control, and backup
Backup Transition Automatic disconnect for
seamless backup
Modularity Supports uptolOAC-
coupled Powerwalls
Optional Internal 200 A 8-space / 12 circuit
Panelboard. breakers
Siemens OF or Square D
HOM breakers rated 10 -
BOA or Eaton BR breakers
rated 10 -125A
Warranty 10 years
When protected by Class 1 fuses, Backup Gateway 21s
suitable for use in circuits capable of delivering not more
than 22kA symmetrical ampama
Cellular connectivity subiect to network operator service
coverage and signal strength.
Environmental
Operating Temperature
-20oC to 50oC (-4°F to 122°F)
Specifications
Operating Humidlty(RH)
Up to 100%,condensing
Maximum Elevation
3000 in (9843 ft)
Environment
Indoor and outdoor rated
Enclosure Type
NEMA 313
Compliance
Certifications
UL 67, UL 669A, UL 916, UL 1741 PCs,
Information
CSA 22.2 0.19, CSA 22.2 205
Emissions
FCC Part 15, ICES 003
Mechanical
Dimensions BBO x 411 x149 men
[1-411 man
�149.
Specifications
(26 x16x 6 in)
— —
_
Inln
Weight 20.4 kg (4516)
I
Mounting options Well mount,
Semi -flush mount
* 2 s u e
I
I
Approved for Construction by:
OOC man
W. Scott Leavelle (TPI)
6-2-26
Ii
20N
Pcwerwall3 Datasheet
J_
Powerwall 3 Example System Configurations
Powerwall 3 with Gateway 3
Whole Home Backup
(C-2-E-S-
4
Grid Meter socket panel Gateway 3 Load center
I
�r
Backup loads Powerwall 3
Powerwall 3 with Backup Switch
I ePeoaa,— 1
Whole Home Backup \ /
—��I
Backup Switch I I
— Solar — l
® Meter � 4 J
Grid Meter socket panel Load center
I
J
Backup loads Powerwall 3
IOPtiwral- �
GT)
I ♦♦/ I
I I
Solar
--
Approved for Construction by:
W. Scott Leavelle (TPI)
6-2-26
Powerwall 3 with Backup Gateway 2
Partial Home Backup \ /
I�� I
Utility Meter I I
0 I —Solar _
Main
(V—P-- Breaker
Grid Meter load center Backup Gateway 2 Load center
1 1
Non -essential loads Backuploads Powerwall 3
20N Powerwall 3 Datasheet a
Solar Shutdown Device Technical Specifications
The Solar Shutdown Device is a Mid -Circuit Interrupter (MCI) and is part of the PV system rapid shutdown (RSD) function in
accordance with Article 690 of the applicable NEC. When paired with Powerwall+, solar array shutdown is Initiated by any loss of
AC power.
Electrical Model Mcl-1 MCF2
Specifications Nominal Input DC Current Rating (I"o) 13 A 13 A
Maximum Input Short Circuit Current (Ise) 19 A 17 A
Maximum System Voltage (PVHCS) 600 V DC 1000 V DOe
'QMaximum System Voltage Is limited by Powerwall+to 600 V DC.
RSD Module
Performance
Environmental
Specifications
Mechanical
Specifications
Maximum Number of Devices per String
Control
Passive State
Maximum Power Consumption
Warranty
Operating Temperature
Storage Temperature
Enclosure Rating
E
Power Line Excitation
Normally Open
7W
25 years
-40°C to 50°C
(-40°F to 122°F)
-30°C to 70°C
(-22-F to 158°F)
NEMA 4x / IP65
5
Power Line Excitation
Normally Open
7W
25 years
-45°C to 70°C
(-49°F to 158°F)
-30°C to 70°C
(-22°F to 158°F)
NEMA 4x / IP65
Electrical Connections
MC4 Connector
MC4 Connector
Housing
Plastic
Plastic
Dimensions
125 x 150 x 22 mm
173 x 45 x 22 mm
(S x6 x1 in)
(6.8 x 1.8 x1 in)
Weight
350 g (0.77 lb)
120 g (0.26 lb)
Mounting Options
ZEP Home Run Clip
Wire Clip
M4 Screw (#10)
MS Bolt (5/16")
Nail / Wood screw
Compliance certifications
Information
RSD Initiation Method
UL 3741 PV Hazard Control
(and PVRSA) Compatibility
UL 1741 PVRSE, UL 3741,
PVRSA (Photovoltaic Rapid Shutdown
External System Shutdown Switch
Approved for Construction by:
W. Scott Leavelle (TPI)
6-2-26
See Powerwall+ Installation Manual
2024 Powerwall+Datasheat 4
i
System designed with 41t All parts fit in a box for easy
` maximum versatility for any logistics
arrays including staggered
f+� Drop -in features make the
f`Jl install process intuitive and fast
Simple design allows system to
be installed by single installer Listed to UL Standard 2703 for
on the roof & Grounding/Bonding and Fire
Classification
Flash Track with Patented Umbrella Technology
Single Umbrella lag screw secures flashing and flash track to roof
in one complete action
Umbrella technology provides weatherproofing with a long-
lasting mechanical seal
Flash track is designed for maximum versatility with 6 inches of
North -South adjustability for all Mounts
rXpP(ovea for Uonsuuouori oy:
W. Scott Leavelle (TPI)
Mounts 6-2-26
• Single mount used at all locations on array
• Extreme time saver by eliminating link interference through the flexibility
of the Mount to change orientation
• Features a rock -in channel nut design for easy attachment to Flash Track
• Slotted riser provides leveling for easy height adjustments `A
�s
Links
• Simple design provides mounting platform between two to four
modules
• Clamps onto top of modules securing them in place while providing
row -to -row bonding
• Next row of modules easily slides into place as with the Mounts
Skirt
• Easily locks to bottom of module mounts and links for clean
aesthetics
• Ensures a strong structure for leveling and alignment of first
row of modules
• Skirt length is compatible with both portrait and landscape
module orientations
DESCRIPTION:
SNAPNRACK, TDS, ALPHATRACK (USA)
PART NUMBERS):
242-10063-USA
UNITS: IN, LB, DEG [MM, KG, DEG3 I SHEET: 1:2
Approved for Construction by:
W. Scott Leavelle (TPI)
6-2-26
DOC NUMBER'.
SNR-DC-01452
D RAWN BY:
H.WULFEKOETTER
REV: PATE:
A I 11/21/2024
snap adko
sNR SOLAR LLc
nns�®SwA
161—Tam�, oNTM,
O
no
PARTS LIST
ITEM IO-ryI DESCRIPTION
1 1 SNAPNRACK, ALPHATRACK, MILL
2 1 SNAPNRACK, BUTYL PAD, 3.75IN X 1.50IN X ,25IN
MATERIALS: 6000 SERIES ALUMINUM, BUTYL
DESIGN LOAD (LBS): VARIES, REFER TO SNAPNRACK ENGINEERING
ULTIMATE LOAD (LBS): VARIES, REFER TO SNAPNRACK ENGINEERING
TORQUE SPECIFICATION: NIA FT-LBS
CERTIFICATION: UL 2703, FILE E359313, DOMESTIC CONTENT COMPLIANT
WEIGHT (LBS): 0.43
DESCRIPTION: DOC NUMBER:
SNAPNRACK, TDS, ALPHATRACK (USA) SNR-DC-01452
D RAWN BY:
PART NUMB ER(S): H. W ULFEKOETTER
242-10063-USA REV: DATE:
UNITS: IN, LB, DEG [MM, KG, DEG] I SHEET: 2:2 A 11/21/2024
-- JS
[1+11
'0
j
4ss
[a7.6]
1.so
Snap ack@
3.)0
[76.2]
SNR SOLAR LLC
s.,®'e 'A' .R.oH..E
3.78
[95.9]
5J5
[145.11
Approved for Construction by:
W. Scott Leavelle (TPI)
1.10 —�
� [28.01 1.27
.15 [321.21
[11z I
} 2.44
�[62.02.0]
FOR SNAPNRACK ENGINEERING TO APPLY, THE EMBEDMENT
CRITERIA SHOWN HEREIN MUST BE MET (IF CRITERIA
CANNOT BE MET OR SPANS ARE NOT SUFFICIENT, CONTACT
SNAPNRACK FOR SUPPORT).
REFER TO SNAPNRACK INSTALLATION MANUAL FOR '&" 0
HARDWARE TORQUE SPECIFICATIONS. REFER TO
MANUFACTUER SPECIFICATIONS FOR OTHER FASTENER
TORQUE REQUIREMENTS.
BUTYL DETAIL
(DECKANCHOR SHOWN)
TRP
TYL
ROOF DECKING
STRUCTURAL ROOF MEMBER��'
(RAFTER) TYP.
REVISION:
A 8/9/2024 D0004258 MKW
A 9/16/2024 DC004258 MKW
DMCI - M-DIAI ND
COMPLETED DECK INSTALLATION
Approved for Construction by:
05/6" S.S. LAG SCREW
W. Scott Leavelle (TPI) ROOFING MATERIAL, TYP.
6-2-26 ALPHATRACK�
ALPHATRACK
/ 2-1/2" MIN. EMBEDMENT
INTO STRUCTURAL MEMBER,
RAFTER TYP. �
ROOF DECKING
ROOF DECKING AND
ROOFING MATERIAL, TYP.
�RAFTER,YP
COMPLETED RAFTER INSTALLATION
����nn���n S Su_ru2ouuthLLCoGwm DESIGNER: M.WATKINS ISM NTS DRAWING NUMBER: DESCRIPTION: REV:
llll\\UII k- „�„EI," •F °„�„�, DRAFTER: M.WATKINS SNR-DC-00370 TOPSPEED UNIVERSAL, ATTACHMENT DETAIL, ^
Solar Mounting Solution:, E,o gppROVED BY: M.AFFENTRANGER I DATE: 9/16/2024 ALPHATRACK /`1