DESCRIPTION OF WORK TO BE DONE: CONSTRUCTION OF NEW 2 -STORY 28,050 SF OFFICE BUILDING
USE OF BUILDING OR STRUCTURE: GENERAL OFFICE / SHOWROOM
NAME OF BUSINESS: HISTORYMAKER HOMES
**Total Square Footage under roof: 28,967 SF Square Footage of alteration/addition: 28,050 SF
X I hereby certify that plans have been reviewed and the building will be inspected by a certified energy code inspector in accordance with
State Law. Plan review and inspection documentation shall be made available to the Building Department (required for new buildings,
alterations and additions)
I hereby certify that plans have been submitted to the Texas Department of Licensing and Regulation for Accessibility Review.
Control Number: &i eaPJ r, 6 6 err- (Not required for 1 & 2 family dwellings)
❑ I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas
N/A Department of Health.
(REQUIRED FOR DEMOLITIONS, ADDITIONS AND OR ALTERATION TO COMMERCIAL AND PUBLIC BUILDINGS)
I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by
the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. It is understood that the issuance of
this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. I FURTHERMORE UNDERSTAND
THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY, AND THAT THE
DESIGN PROFESSIONAL/OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND
OR FEDERAL AGENCY(S).
PRINT NAME:'. EijZi` SIGNATURE v
PH #: J7 335� T FAX #: EMAIL: -
❑ CHECK BOX IF PREFERRED TO BE CONTACTED BY F, -MAIL
THE FOLLOWING IS TO BE COMPLETED BY THE BUILDING INSPECTION DEPARTMENT
Construction Ty e:
Permit Valuation: $
Setbacks
Approval to Issue
Occupancy Group:
Fire Sprinkler: YES t;'—No
Front: , t
Electrical
Division:
Building Depth:
`
Left:
Plumbing
Zoning:ZA
Building Width:
Rear: "
Mechanica
Occupancy Load: St -1
Ar
Right: '
Plan Review Approval:
Date:
! ""-
Building Permit Fee:
'2k, a �
Site Plan Approval:
Date:
Plan Review Fee:
Igo - 9-6
Fire Department:
Date:
Lot Drainage Fee:
//7-2, 5
Public Works Department:
Date:
,
Sewer Availability Rate:
Health Department:------
Date:
Water Availability Rate:
Approved for Permit:
Date:
/ I
Total Fees:
- 13
Lot Drainage Submitted:
Approved:
��%Z
Total Amount Due:
P.O. BOX 95104, GRAPEVINE, TX 76099 (817) 410-3165 OfORMSUSPERMITAPPLICATIONS 1102-Rev.11104,5106,2107,11/09,4/11
FEB 29 20 i6
'RA
Issue Date:
CITY OF GRAPEVINE F L- R 9p,
(CIRCLE ONE)
ELECTRICAL MECHANICAL � -PLUMBING -IRRIGATION -FUEL GAS
P pIT E T APPLICATION
IPLEASE PRINT LEGIBLY - COMPLETE ENTIRE FOPM1
PERMIT #
BLDG. PERMIT # COM -15-4314
T-641:
JOB ADDRESS: 1038 Texan Trail SUITE #
DESCRIPTION OF WORK: Ground up construction of office space
PROPERTY OWNER:
Irving Homes Inc
CONTRACTING COMPANY:
Facility Solutions Group
ADDRESS: 9001 Airport Fwy Ste#400
ADDRESS:2525 Walnut Hill Ste#100
CITYISTATE/ZIP:
North Richland Hills, TX 76180
CITYISTATE/ZIP:
Dallas, TX 75229
PHONE NUMBER: 817-849-5230
PHONE NUMBER: 214-357-5697
TYPE OF OCCUPANCY
BUIL SIGNIFG AREA
j
PERMIT FEES
AMOUNT DUE
EACH TRADE
I. R-3
1- 749
$ 33,25
SINGLE FAMILY, DUPLEX
750- 1,199
$ 49.88
TOWNHOUSE,
1,200- 1,500
$ 63.18
NEW CONSTRUCTION &
1,501- 1,750
$ 76.48
ADDITIONS (PER UNIT)
1,751- 2,000
$ 83.13
2,001- 2,250
$ 89.78
TOTAL SO. FOOT UNDER
2,251- 3,000
$ 96.43
ROOF
3,001- 3,500
$ 103.08
3,501- 4,000
$ 109.73
$
4,001 +
$ 120.37
EACH TRADE
11. A, E, 1, R-1
1- 500
$ 37.00
HOTELS, APARTMENTS,
501 - 100,000
$ 17,50+.035 PER
DRINKING/DINING,
100,001 - 500,000
$ 3,500.00+.03 SQUARE
EDUCATIONAL, ASSEMBLY,
500,001+
$15,000.00+.02 FOOT
$
INSTITUTIONAL
Ill. EF, H, M, S, U
EACH TRADE
28050 sq. ft.
OFFICE, RETAIL, WHOLESALE,1-
snn
$ 37.00
$32+$280.50
50 1- 50,000
GARAGES, FACTORIES,
$ 32.00+.01 PER
J
WORKSHOPS, SERVICE
$ 182.00+.ou SQUARE
5U'001- 100,000
STATIONS, WAREHOUSE
100,001+
$ 582.00+.003 FOOT
312 .50
CONTRACT
EACH TRADE
IV. ANY OCCUPANCY GROUP
VALUATION OF
WORK
FINISH -OUTS,
SHELL COMPLETIONS,
0- 500
$ 37.00
ALTERATIONS OR
501- 1,500
$ 45.00
STAND ALONE PERMITS
1,501- 3,000
$ 57.00
3,001- 5,000
$ 72.00
CONTRACT VALUATION OF WORK:
5,001- 50,000
$ 27.00+.009
50,001- 100,000
$ 127.00+ .007 PER
$
100,001- 500,000
I $ 327,00+ .005 DOLLAR
500,001+
$ 1,327.00+.003 VALUATION
EACH TRADE
V. MISCELLANEOUS
IRRIGATION SYSTEMS
$ 37.00
MOBILE HOME SERVICE
$ 37.00
TEMPORARY POLE SERVICE
$ 37.00
SWIMMING POOLS
$ 37.00
SIGN ELECTRIC
$ 37,00
$
C.AUsP.rqk.Ahnftn1AnnDAtakI n(.aIkMiffoqnft%WindowsITP.mnorary Intamp.tF:ilp.,;k(,nntent0titlnnk%G8()FSGOF%MFPAPPLICATION 4-11 dor.
PLAN SUBMITTAL:
WHEN PLANS ARE REQUIRED BY CODES, ORDINANCES, OR AS DETERMINED BY THE BUILDING
OFFICIAL, THREE (3) SETS OF PLANS SHALL BE SUBMITTED IN HARD COPY FORMAT. ENGINEER SEALED
PLANS AND CALCULATIONS SHALL BE SUBMITTED AS REQUIRED BY CODES, ORDINANCES OR WHERE
OTHERWISE REQUIRED BY STATE LAW.
OTHER INSPECTIONS AND FEES:
• INSPECTIONS OUTSIDE NORMAL BUSINESS HOURS (2HR MINIMUM)...............................................$42.00/HOUR'
• REINSPECTION FEES.................................................................................................................. $42.00
• PERMITS FOR WHICH NO FEE IS SPECIFICALLY INDICATED.. .................... .................. ................ . $37.00
• INSPECTIONS FOR WHICH NO FEE IS SPECIFICALLY INDICATED (1/2 HOUR MINIMUM)- .................... $42.00/HOUR
• ADDITIONAL PLAN REVIEW REQUIRED BY CHANGES, ADDITIONS, OR REVISIONS TO
APPROVEDPLANS ..... ............ .................. .................. ............... ........... ........ ................................ $42.00/HOUR
• BUILDING PERMIT FEES FOR THE GRAPEVINE-COLLEYVILLE INDEPENDENT SCHOOL DISTRICT
SHALL BE 25% OF THE FEES ESTABLISHED IN THIS TABLE
• FOR USE OF OUTSIDE CONSULTANTS FOR PLAN CHECKING AND INSPECTIONS, OR BOTH......... ACTUAL COSTS*"
I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE
PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE
WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF
THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF
GRAPEVINE,
I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND / OR
LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS,
AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST.
SIGNATURE OF CONTRACTOR OR AUTHORIZED AGENT
(OR HOMEOWNER FOR HOMEOWNERS PERMITS)
PHONE #:
PRINTED NAME
EMAIL:
"OR THE TOTAL HOURLY COST TO THE JURISDICTION WHICHEVER IS GREATER.
—ACTUAL COSTS INCLUDE ADMINISTRATIVE AND OVERHEAD COSTS.
Development Services Department, Building Inspections
The City of Grapevine * P.O. Box 95104 * Grapevine, Texas 76099 * (817) 410-3165
Fax (817) 410-3012 * www.grapevinetexas.gov
. _ sr t. :.=.fir "dG2 . xas: t <.•r, . �Yt+. f., .su sT� ori , ;ntnr I F. � ze. i -r i,�cK s,r: E.,..=L. .. , . ,C A7+ - 14 4 =, T Fi-.i;
V NE Ems.
IT N X A 8 JAN 14 2016 CITY OF GRAPEVINE
V� (CIRCLE ONE)
MECHANICAL - ELECTRICAL -'vf�LUMBING - IRRIGATION - FUEL GAS
PERMIT APPLICATION
(PLEASE PV411T LFr.lgl Y - r#11,71PI FTF
PERMIT #
BLDG. PERMIT #
DATE:
JOB ADDRESS: IcKt. 7-ex.-ull J SUIT t #
DESCRIPTION OF WORK:
PROPERTY OWNER:
CONTRACTING COMPANY:
.. _/_x/ Z.
ADDRESS:
ADDRESS:
CITYISTATE/ZIP:
CITY/STATE/ZIP:
v/
50chlilknle 7
PHONE NUMBER:
PHONE NUMBER:
?12 575//
TYPE OF OCCUPANCY
BUILDING AREA
(SO FT)
PERMIT FEES
AMOUNT DUE
EACH TRADE
I. R-3
1- 749
$ 33.25
SINGLE FAMILY, DUPLEX
750- 1,199
$ 49.88
TOWNHOUSE,
1,200- 1,500
$ 63.18
NEW CONSTRUCTION &
1,501- 1,750
$ 76.48
ADDITIONS (PER UNIT)
1,751- 2,000
$ 83.13
2,001 - 2,250
$ 89.78
TOTAL SQ. FOOT UNDER
2,251- 3,000
$ 96.43
ROOF
3,001- 3,500
$ 103.08
3,501 - 4,000
$ 109.73
4,001 +
$ 120.37
EACH TRADE
Ill. A, E, 1, R-1
1 - 500
$ 37.00
HOTELS, APARTMENTS,
501 - 100,000
$ 17.50+.035 PER
DRINKING/DINING,
100,001 - 500,000
$ 3,500.00+.03 SQUARE
EDUCATIONAL, ASSEMBLY,
500,001 +
$15,000.00+.02 FOOT
INSTITUTIONAL
41117 �i, F, H, PIA, S, U
EACH TRADE
'-�"OFFICE, RETAIL, WHdLESALE,
1- 500
$ 37.00
GARAGES, FACTORIES,
501- 50,000
$ 32.00+ . 01 PER
f
WORKSHOPS, SERVICE
50,001- 100,000
$ 182.00+.007 SQUARE
STATIONS, WAREHOUSE
100,001+
$ 582.00+ .003 FOOT
CONTRACT
EACH TRADE
IV. ANY OCCUPANCY GROUP
VALUATION OF
WORK
FINISH -OUTS,
SHELL COMPLETIONS,
0- 500
$ 37.00
ALTERATIONS OR
501- 1,500
$ 45.00
STAND ALONE PERMITS
1,501- 3,000
$ 57.00
3,001- 5,000
$ 72.00
CONTRACT VALUATION OF WORK:
5,001- 50,000
$ 27.00+.009
$_ 3
50,001- 100,000
100,001- 500,000
500,001+
$ 127.00+.007 PER
$ 327.00+ .005 DOLLAR
$ 1,327.00+.003 IVALUATION
$
EACH TRADE
V. MISCELLANEOUS
IRRIGATION SYSTEMS
$ 37.00
MOBILE HOME SERVICE
$ 37.00
TEMPORARY POLE SERVICE
$ 37.00
SWIMMING POOLS
$ 37.00
SIGN ELECTRIC
$ 37.00
r*klJ.qpr_q\.,hattp.\AnnDpfp\l or.AhMirmqnffkWinrinw kTp.mnnraiv Intp.rnpf Filp.qkrontf-.nt.Oijtlnnkk(,ROFRCOFkMFP APPI ICATinN 4-11 tion
WHEN PLANS ARE REQUIRED BY CODES, ORDINANCES, OR AS DETERMINED BY THE BUILDING
OFFICIAL, THREE (3) SETS OF PLANS SHALL BE SUBMITTED IN HARD COPY FORMAT. ENGINEER SEALED
PLANS AND CALCULATIONS SHALL BE SUBMITTED AS REQUIRED BY CODES, ORDINANCES OR WHERE
OTHERWISE REQUIRED BY STATE LAW.
• INSPECTIONS OUTSIDE NORMAL BUSINESS HOURS (2HR MINIMUM)...............................................$42.00/HOUR"
• REINSPECTION FEES.................................................................................................................. $42.00
• PERMITS FOR WHICH NO FEE IS SPECIFICALLY INDICATED........................................................... $37.00
• INSPECTIONS FOR WHICH NO FEE IS SPECIFICALLY INDICATED (1/2 HOUR MINIMUM)......................$42.00/HOUR
• ADDITIONAL PLAN REVIEW REQUIRED BY CHANGES, ADDITIONS, OR REVISIONS TO
APPROVEDPLANS.......................................................................................................................$42.00/HOUR
• BUILDING PERMIT FEES FOR THE GRAPEVINE-COLLEYVILLE INDEPENDENT SCHOOL DISTRICT
SHALL BE 25% OF THE FEES ESTABLISHED IN THIS TABLE
• FOR USE OF OUTSIDE CONSULTANTS FOR PLAN CHECKING AND INSPECTIONS, OR BOTH......... ACTUAL COSTS*
I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE
PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE
WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF
THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF
GRAPEVINE.
I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND / OR
LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS,
AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST.
t e
SIGNATURE OF CONTRACTOR OR AUTHORIZED AGENT
(OR HOMEOWNER FOR HOMEOWNERS PERMITS)
PHONE #: l S
PRINTE .NAME
EMAIL:
*OR THE TOTAL HOURLY COST TO THE JURISDICTION WHICHEVER IS GREATER.
**ACTUAL COSTS INCLUDE ADMINISTRATIVE AND OVERHEAD COSTS.
Development Services Department, Building Inspections
The City of Grapevine * P.O. Box 95104 * Grapevine, Texas 76099 * (817) 410-3165
Fax (817) 410-3012 * www.grapevinetexas.gov
C"\1J3P.LC\ahattP\AnnDatnM ncal\Minrnsnff\Winrinws\Tamnnraro IntP.rnP.t Filar\Cnntent.0utinnklGAOFfiGOF\MFP APPI (CATION 4-I l Ann
a Lei 11.1 o
DATE: —1 15 11 / BUILDING ✓
--- ,--- SWIMMING POOL
ADDRESS: ®� Z40 ✓t .
IRRIGATION
PERMIT # _f WATER HEATER
I hereby certify that I have inspected the water supply system at the above referenced address. To the best of my
knowledge, the materials and methods used in the installation of this system comply with all laws of the State of Texas
relating to plumbing that are required to be enforced by municipalities, and the plumbing code adopted by the City of
Grapevine. Plumbing regulations are contained in the City of Grapevine Code of Ordinances Article V (Ordinance
number 2007-36) and Article VIII (Ordinance number 2007-36), and any and all subsequent related ordinances.
In addition, to the best of my knowledge, no cross connection exists at this address at the time of inspection.
SIGNATURE OF INSIPECTOR TITLE
:L
�'2,S90
�
LICENSE NUMBER
O:\forms\waterservinsp, 05/01
Revised: 7123/14
SEP 15 2016
i A' 0
57.71 11 WONT:11
•rTIM a•• • a aislet; 101112,11,•
building. It is further understood that this temporary release is for a thirty
(30) day maximum time period and the undersigned releases all claims that
may occur through accidents or spoilage of any type resulting from said
electric power beingturnedoffat the end ofthe thirty0 day
time period.
0
�: .�.,:�.�
1 19
NA E OF APPLICANT:c,
ADDRESS OF APPLICANT:12
4r e -r-4- iv�x S°ut` r oc
CITY, STATE, ZIP:K/
9C
TELEPHONE UMBER:
�11
INSPECTIONS FOR TEMPORARY POWER MUST BE REQUESTED
T (817) 410-3010
O:FORMS\DS CONTRACTOR FORMS\TEMP ELEC.doc
10/12/00 Revised: 4/10/02
eL-f n 06/0v
JT NAME:
®ATE:
111111111120
MAN
S
'1101 i A 0 .
•• •• •JI
R i. i t t tt
• • i r • i • • • • o • 11
imm ii
f - t,,f • ;f i
maximum f me period and the undersigned
releases all claims that may occur through accidents or spoilage of any
type resulting from i gaspower beingturned off atthe end of
thirty (30) day maximum time period.
An 91 i O • • ' •
ADDRESS:
'!• , <
PERMIT U / - q3 /
NAME OF .P
I STATE, ZIP:
WE WA
i
FOR TEMPORARY , REQUESTED
410-3010
/ .j , r:
SIGNITU PRINT NAMI=-: DAT
4/10/02
Cnp
IIV ;,
PERMIT NO. /5--� 3Z � ADDRESS: lo3 9' T-�h'Qn %_ra/*
BUILDER: -T-i^vr'✓t9 #0/nes
The above referenced address meets or exceeds the requirements for protection
against termites set forth in the 2006 International Residential Code and the treatment
was done in compliance with the Regulations of the Structural Pest Control Board of
Texas and the EPA Registered Manufacturer's Directions for the Use of Pesticides.
Name of Protection Provider (Company):
joidM oA�1J'T iec l 60,1�re /
Address: P®. j9oX 56 g' -3/0
Almerg 7?-
Phone II ,2 1 � -5 2 7 ..>1 9'l?
State License No.: 1 ;Z q 7
STATE OF TEXAS
COUNTY OF l r( -a V T
I, S�nCIf , being duly sworn both deposed and say that
the information contained in the above application is true and correct to the best of my
know] dge an elief.
Sigriatur Date
Subscribed and sworn to before me this ) day of. At-emmer , 20�,
A.D.
Notary Public i and for the State of Texas
STAGY BELL
0110
O:\FORMS\DS CONTRACTOR FORMS\TERMITE PROTECTION.doc
0907
;gig NOTARY
+�f?
PUBLIC STATE CiF TEXAS
-.,r,�;•...�°}'
COW EXP02-14-2018
host ti�+"r�
NOTARY ID 125583435
ID E "C" 1, q 2016
ENERGY CONSERVATION INSPECTION CERTIFICATION FORM
) 2, —/ 4--/ (ALL OCCUPANCIES EXCEPT SINGLE FAMILY RESIDENTIAL)
Project Name:
Address of Insl
Name of Company Performing Inspection:_ , 'AJt+y0 C-n� flif
Name of Certified Inspector Performing Inspection: �Co O&Vaa--o
ICC Energy Code Inspector Certification Number: 11�01 Q05�
In accordance with State Law (Senate Bill 5 enacted by the 77th Legislature of the State
of Texas), I hereby certify that I have inspected the above referenced structure and that
it complies with the International Energy Conservation Code and any Amendments
adopted by the State of Texas and / or the City of Grapevine.
Signature of Inspector
Development Services Department
The City of Grapevine * P.O. Box 95104 4 Grapevine, Texas 76099 * (817) 410-3165
Fax (817) 410-3012 * www.grapevinetexas.gov
0-"FORMSIDS ENERGY CODE RELATECACornmewAal Conrple0on Gen. Energy Gade.doc
M007;Re,r.242
CITY OF
BUILDING
PRE -CONSTRUCTION
This is not intended to be a compr+
guide to aid in the construction process.
tobea
i Provide clear and fully legible Project Site Address Sign, readable from the curb.
® No work (including sitework) may proceed prior to issuance of a Building Permit and/or
written approval by the Building Official.
Separate Permits are also required for all mechanical, electrical, and plumbing work,
signs (permanent and temporary) and banners.
Each building and/or structure requires a Separate Permit.
Working hours in the City of Grapevine are 7:00 AM to 7:00 PM Monday through Saturday.
No Work allowed on Sunday.
Building or structure in a residential district or non-residential district, excluding any
inside work done in an enclosed building or structure in nonresidential districts.
,,,,,,No sitework and/or tree removal is permitted prior to receiving a tree inspection and
written approval from the building inspector.
No work may be covered prior to receiving written approval from the inspector. All
inspection approvals should be kept on site by the project manager.
Inspections requested prior to 7:30 A.M. will usually be performed the same morning.
Inspections requested by 12:30 P.M. will usually be received that afternoon. Inspection
request phone number is (817) 410-3010. After hours inspections are strictly voluntary.
Provide a copy of the Foundation Setback Survey for City Of Grapevine approval. Your
surveyor may fax this to the Building Department at (817) 410-3012.
No inspections on building pad will be made prior to City approval of a Foundation
Setback Survey.
No changes from - City approved plans
first submitting revised plans and receiving written approval from the BuildingDepartment. This includes signs, landscaping, lighting, etc. i
COMcheck Software • i
Envelope r Compliance ,
Section 1: Project Information
Gross
Area or
Perimeter
Project Type: New Construction
Cont. Proposed
R -Value U -Factor
Project Title : History Maker Corporate Headquarters
Roof 1: Attic Roof with Wood Joists
Construction Site: Owner/Agent:
Designer/Contractor:
1038 Texan Trail Irving Homes
Michael Bennett
Grapevene, TX 76051 9001 Airport Freeway
Bennett Benner Partners Architects
Suite 400
500 West 7th Street
North Richland Hills, TX 76180
Suite 1400
817 849-5100
Fort Worth, TX 76102
--- 0.320
817 335-4991
Section 2: General Information
Building Location (for weather data): Grapevine, Texas
Climate Zone: 3a
Vertical Glazing /Wall Area Pct.: 40%
Activity Type(s) Floor Area
Office 21250
Retail 4000
Section 3: Requirements Checklist
Climate -Specific Requirements:
Component Name/Description
Gross
Area or
Perimeter
Cavity
R -Value
Cont. Proposed
R -Value U -Factor
Budget
U-Factor(a)
Roof 1: Attic Roof with Wood Joists
14025
0.0
20.0 0.046
0.027
Brick Venner Wall: Wood -Framed, 16" o.c.
15390
13.0
0.0 0.089
0.089
CW -1 (2): Metal Frame Curtain Wall/Storefront: Double Pane with
186
---
--- 0.320
0.600
Low -E, Clear, SHGC 0.27
CW -2 (1): Metal Frame Curtain Wall/Storefront: Double Pane with
212
---
--- 0.320
0.600
Low -E, Clear, SHGC 0.27
CW -3 (2): Metal Frame Curtain Wall/Storefront: Double Pane with
160
---
--- 0.320
0.600
Low -E, Clear, SHGC 0.27
CW -4 (3): Metal Frame Curtain Wall/Storefront: Double Pane with
465
---
--- 0.320
0.600
Low -E, Clear, SHGC 0.27
CW -5 (1): Metal Frame Curtain Wall/Storefront: Double Pane with
272
---
--- 0.320
0.600
Low -E, Clear, SHGC 0.27
CW -6 (1): Metal Frame Curtain Wall/Storefront: Double Pane with
332
---
--- 0.320
0.600
Low -E, Clear, SHGC 0.27
SF -3: Metal Frame Curtain Wall/Storefront: Double Pane with Low -E,
128
---
--- 0.320
0.600
Clear, SHGC 0.27, PF 0.65
SF -6: Metal Frame Curtain Wall/Storefront: Double Pane with Low -E,
420
---
--- 0.320
0.600
Clear, SHGC 0.27, PF 0.60
SF -7: Metal Frame Curtain Wall/Storefront: Double Pane with Low -E,
631
---
--- 0.320
0.600
Clear, SHGC 0.27
SF -8 102-1: Glass (> 50% glazing):Metal Frame, Entrance Door,
59
---
--- 0.320
0.900
SHGC 0.27, PF 1.00
Project Title: History Maker Corporate Headquarters Report date: 11/30/15
Data filename: E:\no15117.00 Historymaker Homes\04 Regulatory\04-01 City\HMH Energy Comcheck.cck Page 1 of 2
SF -8 114-1: Glass (> 50% glazing):Metal Frame, Entrance Door, 59 --- --- 0.320 0.900
SHGC 0.27, PF 0.38
SF -8: Glass (> 50% glazing):Metal Frame, Non -Entrance Door, 236 --- --- 0.320 0.650
SHGC 0.27
SF -13 (8): Metal Frame Curtain Wall/Storefront: Double Pane with 336 --- --- 0.320 0.600
Low -E, Clear, SHGC 0.27
SF -14: Metal Frame Curtain Wall/Storefront: Double Pane with 532 --- --- 0.320 0.600
Low -E, Clear, SHGC 0.27, PF 0.73
SF -15 115-8: Glass (> 50% glazing):Metal Frame, Non -Entrance 58 --- --- 0.240 0.650
Door, SHGC 0.27
SF -17 112-1: Glass (> 50% glazing):Metal Frame, Non -Entrance 49 --- --- 0.240 0.650
Door, SHGC 0.27, PF 0.43
SF -20 (2): Metal Frame Curtain Wall/Storefront:Double Pane with 50 --- --- 0.320 0.600
Low -E, Clear, SHGC 0.27, PF 0.43
SF -23 (3): Metal Frame Curtain Wall/Storefront: Double Pane with 66 --- --- 0.320 0.600
Low -E, Clear, SHGC 0.27
SF -26 (10): Metal Frame Curtain Wall/Storefront:Double Pane with 1840 --- --- 0.320 0.600
Low -E, Clear, SHGC 0.27, PF 0.69
door 111-1: Insulated Metal, Swinging 21 --- --- 0.240 0.700
door 134-2: Glass (> 50% glazing):Metal Frame, Non -Entrance 128 --- --- 0.240 0.650
Door, SHGC 0.27
Stucco Roof Wall: Wood -Framed, 16" o.c. 175 13.0 0.0 0.089 0.089
Concrete Slab: Slab -On -Grade: Unheated 503 --- --- --- ---
(a) Budget U -factors are used for software baseline calculations ONLY, and are not code requirements.
Air Leakage, Component Certification, and Vapor Retarder Requirements:
F-1 1. All joints and penetrations are caulked, gasketed or covered with a moisture vapor -permeable wrapping material installed in accordance
with the manufacturer's installation instructions.
F1 2. Windows, doors, and skylights certified as meeting leakage requirements.
F1 3. Component R -values & U -factors labeled as certified.
u 4. No roof insulation is installed on a suspended ceiling with removable ceiling panels.
❑ 5. 'Other' components have supporting documentation for proposed U -Factors.
Fi 6. Insulation installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that
achieves the rated R -value without compressing the insulation.
F1 7. Stair, elevator shaft vents, and other outdoor air intake and exhaust openings in the building envelope are equipped with motorized
dampers.
Lj 8. Cargo doors and loading dock doors are weather sealed.
❑ 9. Recessed lighting fixtures installed in the building envelope are Type IC rated as meeting ASTM E283, are sealed with gasket or caulk.
F1 10. Building entrance doors have a vestibule equipped with closing devices.
Exceptions:
Building entrances with revolving doors.
Doors that open directly from a space less than 3000 sq. ft. in area.
Section 4: Compliance Statement
Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications
and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 2009 IECC
requirements in COMcheck Version 3.8.1 and to comply with the mandatory requirements in the Requirements Checklist.
Name - Title Signature Date
Project Title: History Maker Corporate Headquarters Report date: 11/30/15
Data filename: E:\no15117.00 Historymaker Homes\04 Regulatory\04-01 City\HMH Energy Comcheck.cck Page 2 of 2
Section 1: Project Information
Energy Code: 2009 IECC
Project Title: Historymaker Homes Corporate Office
Project Type: New Construction
Construction Site: Owner/Agent:
1038 Texan Trail
Grapevine, TX 76051
Historymaker Homes
Section 2: General Information
Building Location (for weather data): Grapevine, Texas
Climate Zone: 3a
Section 3: Mechanical Systems List
Quantity System Type & Description
Designer/Contractor:
Philip Smart, P.E.
HPMB Consulting Engineers, Inc.
2828 Trinity Mills Rd.
Suite 210
Carrollton, TX 75006
214-483-6202
RTU -1 (Multiple -Zone) :
Heating: 1 each - Central Furnace, Gas, Capacity = 350 kBtu/h
Proposed Efficiency = 80.00% Ec, Required Efficiency = 80.00% Ec
Cooling: 1 each - Single Package DX Unit, Capacity = 588 kBtu/h, Air -Cooled Condenser, Air Economizer
Proposed Efficiency = 10.40 EER, Required Efficiency = 9.80 EER
Fan System: FAN SYSTEM 1 -- Compliance (Brake HP method) : Passes
Fans:
FAN 1 Supply, Multi -Zone VAV, 18570 CFM, 20.0 motor nameplate hp, 19.9 brake hp
RTU -2 (Multiple -Zone) :
Heating: 1 each - Central Furnace, Gas, Capacity = 350 kBtu/h
Proposed Efficiency = 80.00% Ec, Required Efficiency = 80.00% Ec
Cooling: 1 each - Single Package DX Unit, Capacity = 588 kBtu/h, Air -Cooled Condenser, Air Economizer
Proposed Efficiency = 10.40 EER, Required Efficiency = 9.80 EER
Fan System: FAN SYSTEM 1 -- Compliance (Brake HP method) : Passes
Fans:
FAN 1 Supply, Multi -Zone VAV, 18570 CFM, 20.0 motor nameplate hp, 19.9 brake hp
AC-1/CU-1 (Single Zone) :
Cooling: 1 each - Split System, Capacity = 18 kBtu/h, Air -Cooled Condenser, No Economizer, Economizer
exception: None
Proposed Efficiency = 15.30 SEER, Required Efficiency = 13.00 SEER
Fan System: FAN SYSTEM 2 -- Compliance (Motor nameplate HP method) : Passes
Fans:
FAN 2 Supply, Constant Volume, 425 CFM, 0.1 motor nameplate hp
AC-2/CU-2 (Single Zone) :
Cooling: 1 each - Split System, Capacity = 18 kBtu/h, Air -Cooled Condenser, No Economizer, Economizer
exception: None
Proposed Efficiency = 15.30 SEER, Required Efficiency = 13.00 SEER
Fan System: FAN SYSTEM 2 -- Compliance (Motor nameplate HP method) : Passes
Fans:
FAN 2 Supply, Constant Volume, 425 CFM, 0.1 motor nameplate hp
Project Title: Historymaker Homes Corporate Office Report date: 11/24/15
Data filename: H:\Jobs\2015\H15136 History Maker Homes\Engineering\Energy\COMcheck\Historymaker Mechanical
EH -1 & 2 (Unknown) :
Heating: 1 each - Unit Heater, Electric, Capacity = 10 kBtu/h
No minimum efficiency requirement applies
Fan System: FAN SYSTEM 3 -- Compliance (Motor nameplate HP method) : Passes
Fans:
FAN 3 Supply, Constant Volume, 175 CFM, 0.1 motor nameplate hp
WH -1 & 2:
Gas Instantaneous Water Heater, Capacity: 0 gallons, Input Rating: 199 Btu/h
Proposed Efficiency: 0.95 EF, Required Efficiency: 0.67 EF
WH -3:
Electric Storage Water Heater, Capacity: 10 gallons w/ Circulation Pump
No minimum efficiency requirement applies
Section 4: Requirements Checklist
Requirements Specific To: RTU -1 :
1. Equipment minimum efficiency: Central Furnace (Gas): 80.00 % Ec
F-1 2, Equipment minimum efficiency: Single Package Unit: 9.80 EER (9.5 IPLV)
C] 3. Minimum one temperature control device per zone
Lj 4. Integrated economizer is required for this location and system.
❑ 5. Cooling system provides a means to relieve excess outdoor air during economizer operation.
F -I 6. Systems serving more than one zone must be VAV systems
Exception(s):
Where pressure relationships must be maintained
Zones or supply air systems with at least 75% of reheating/recooling energy site recovered or site solar
F-1 Zones with humidity requirements for special processes
❑ Zones with cfm <300 and flow rate <10% of total design flow rate
❑ Outside air needed to meet IMC Chapter 4
n 7. Single -duct VAV terminals reduce primary air before reheating
F -i 8. Controls capable of resetting supply air temp (SAT) by 25% of SAT -room temp difference
Exception(s):
F -I Systems that prevent reheating, recooling or mixing of heated and cooled supply air
❑ Seventy five percent of the energy for reheating is from site -recovered or site solar energy sources.
Zones with peak supply air quantities of 300 cfm (142 L/s) or less.
9. VAV fan — 10 hp are driven by mechanical or electrical variable speed drive, or driven by vane -axial with variable speed blades, or
operate with motor demand <=30% design kW at 50% design flow - calculations required
F1 10. Hot gas bypass prohibited unless system has multiple steps of unloading or continuous capacity modulation
11. Hot gas bypass limited to 25% of total cooling capacity
12.VAV fans with static pressure sensors are placed in a position such that the controller setpoint is no greater than one-third the total
design fan static pressure. If placement results in the sensor being located downstream of major duct splits, multiple sensors are
installed in each major branch.
Exception(s):
F1 Systems with DDC of individual zone boxes reporting to the central control panel and reset of static pressure setpoint based on
the zone requiring the most pressure.
n 13.Systems with DDC of individual zone boxes reporting to the central control panel has static pressure setpoint reset based on the zone
requiring the most pressure.
Requirements Specific To: RTU -2 :
1. Equipment minimum efficiency: Central Furnace (Gas): 80.00 % Ec
❑ 2. Equipment minimum efficiency: Single Package Unit: 9.80 EER (9.5 IPLV)
❑ 3. Minimum one temperature control device per zone
[-1 4. Integrated economizer is required for this location and system.
❑ 5. Cooling system provides a means to relieve excess outdoor air during economizer operation.
❑ 6. Systems serving more than one zone must be VAV systems
Exception(s):
L) Where pressure relationships must be maintained
Zones or supply air systems with at least 75% of reheating/recooling energy site recovered or site solar
Zones with humidity requirements for special processes
Project Title: Historymaker Homes Corporate Office Report date: 11/24/15
Data filename: H:\Jobs\2015\H15136 History Maker Homes\Engineering\Energy\COMcheck\Historymaker Mechanical
❑ Zones with cfm <300 and flow rate <10% of total design flow rate
Outside air needed to meet IMC Chapter 4
F-1 7. Single -duct VAV terminals reduce primary air before reheating
❑ 8. Controls capable of resetting supply air temp (SAT) by 25% of SAT -room temp difference
Exception(s):
❑ Systems that prevent reheating, recooling or mixing of heated and cooled supply air
L] Seventy five percent of the energy for reheating is from site -recovered or site solar energy sources.
L] Zones with peak supply air quantities of 300 cfm (142 Us) or less.
n 9. VAV fan — 10 hp are driven by mechanical or electrical variable speed drive, or driven by vane -axial with variable speed blades, or
operate with motor demand <=30% design kW at 50% design flow - calculations required
n 10. Hot gas bypass prohibited unless system has multiple steps of unloading or continuous capacity modulation
F1 11. Hot gas bypass limited to 25% of total cooling capacity
Li 12.VAV fans with static pressure sensors are placed in a position such that the controller setpoint is no greater than one-third the total
design fan static pressure. If placement results in the sensor being located downstream of major duct splits, multiple sensors are
installed in each major branch.
Exception(s):
Ll Systems with DDC of individual zone boxes reporting to the central control panel and reset of static pressure setpoint based on
the zone requiring the most pressure.
Ej 13.Systems with DDC of individual zone boxes reporting to the central control panel has static pressure setpoint reset based on the zone
requiring the most pressure.
Requirements Specific To: AC-1/CU-1 :
Lj 1. Equipment minimum efficiency: Split System: 13.00 SEER
Requirements Specific To: AC-2/CU-2:
F -I 1. Equipment minimum efficiency: Split System: 13.00 SEER
Requirements Specific To: EH -1 & 2
None
Requirements Specific To: WH -1 & 2:
n 1. Water heating equipment meets minimum efficiency requirements: Gas Instantaneous Water Heater efficiency: 0.67 EF
F1 2. First 8 ft of outlet piping is insulated
Requirements Specific To: WH -3:
F-1 1. Water heating equipment meets minimum efficiency requirements: No efficiency requirements for water heater with storage capacity
less than 20 gallons.
F-1 2. All piping in circulating system insulated
3. Hot water storage temperature controls that allow setpoint of 90°F for non -dwelling units and 110°F for dwelling units.
Ll 4. Automatic time control of heat tapes and recirculating systems present
F -I 5. Controls will shut off operation of circulating pump between water heater/boiler and storage tanks within 5 minutes after end of heating
cycle
Generic Requirements: Must be met by all systems to which the requirement is applicable:
Ej 1. Plant equipment and system capacity no greater than needed to meet loads
Exception(s):
Standby equipment automatically off when primary system is operating
n Multiple units controlled to sequence operation as a function of load
2. Minimum one temperature control device per system
3. Minimum one humidity control device per installed humidification/dehumidification system
o 4. Load calculations per ASHRAE/ACCA Standard 183.
n 5. Automatic Controls: Setback to 55°F (heat) and 85°F (cool); 7 -day clock, 2 -hour occupant override, 10 -hour backup
Exception(s):
L] Continuously operating zones
Lj 6. Outside -air source for ventilation; system capable of reducing OSA to required minimum
F1 7. R-5 supply and return air duct insulation in unconditioned spaces
R-8 supply and return air duct insulation outside the building
R-8 insulation between ducts and the building exterior when ducts are part of a building assembly
Exception(s):
Ducts located within equipment
Ducts with interior and exterior temperature difference not exceeding 15°F.
Project Title: Historymaker Homes Corporate Office Report date: 11/24/15
Data filename: H:\Jobs\2015\H15136 History Maker Homes\Engineering\Energy\COMcheck\Historymaker Mechanical
n 8. Mechanical fasteners and sealants used to connect ducts and air distribution equipment
U 9. Ducts sealed - longitudinal seams on rigid ducts; transverse seams on all ducts; UL 181A or 181B tapes and mastics
C] 10. Hot water pipe insulation: 1.5 in. for pipes —1.5 in. and 2 in. for pipes >1.5 in.
Chilled water/refrigerant/brine pipe insulation: 1.5 in. for pipes —1.5 in. and 1.5 in. for pipes >1.5 in.
Steam pipe insulation: 1.5 in. for pipes —1.5 in. and 3 in. for pipes >1.5 in.
Exception(s):
Piping within HVAC equipment.
❑ Fluid temperatures between 55 and 105°F.
❑ Fluid not heated or cooled with renewable energy.
0 Piping within room fan -coil (with AHR1440 rating) and unit ventilators (with AHR1840 rating).
I] Runouts <4 ft in length.
❑ 11.Operation and maintenance manual provided to building owner
F-1 12.Thermostatic controls have 5°F deadband
Exception(s):
F-1 Thermostats requiring manual changeover between heating and cooling
F1 Special occupancy or special applications where wide temperature ranges are not acceptable and are approved by the authority
having jurisdiction.
F-1 13.13alancing devices provided in accordance with IMC 603.17
F1 14. Demand control ventilation (DCV) present for high design occupancy areas (>40 person/1000 ft2 in spaces >500 ft2) and served by
systems with any one of 1) an air -side economizer, 2) automatic modulating control of the outdoor air damper, or 3) a design outdoor
airflow greater than 3000 cfm.
Exception(s):
L] Systems with heat recovery.
0 Multiple -zone systems without DDC of individual zones communicating with a central control panel.
LJ Systems with a design outdoor airflow less than 1200 cfm.
0 Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm.
Fi 15. Motorized, automatic shutoff dampers required on exhaust and outdoor air supply openings
Exception(s):
F-1 Gravity dampers acceptable in buildings <3 stories
16.Automatic controls for freeze protection systems present
I] 17. Exhaust air heat recovery included for systems 5,000 cfm or greater with more than 70% outside air fraction or specifically exempted
Exception(s):
Hazardous exhaust systems, commercial kitchen and clothes dryer exhaust systems that the International Mechanical Code
prohibits the use of energy recovery systems.
Systems serving spaces that are heated and not cooled to less than 60°F.
L) Where more than 60 percent of the outdoor heating energy is provided from site -recovered or site solar energy.
F1 Heating systems in climates with less than 3600 HDD.
[J Cooling systems in climates with a 1 percent cooling design wet -bulb temperature less than 64°F.
I] Systems requiring dehumidification that employ energy recovery in series with the cooling coil.
❑ Laboratory fume hood exhaust systems that have either a variable air volume system capable of reducing exhaust and makeup air
volume to 50 percent or less of design values or, a separate make up air supply meeting the following makeup air requirements:
a) at least 75 percent of exhaust flow rate, b) heated to no more than 2°F below room setpoint temperature, c) cooled to no lower
than 3°F above room setpoint temperature, d) no humidification added, e) no simultaneous heating and cooling.
Section 5: Compliance Statement
Compliance Statement. The proposed mechanical design represented in this document is consistent with the building plans, specifications
and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2009 IECC
requirements in COMcheck Version 4.0.1 and to comply with the mandatory requirements in the Requirements Checklist.
Philip Smart, P.E. - Mechanical Engineer
Name - Title
Signature
11-24-15
Date
Section 6: Post Construction Compliance Statement
F-1 HVAC record drawings of the actual installation, system capacities, calibration information, and performance data for each equipment
provided to the owner.
(] HVAC O&M documents for all mechanical equipment and system provided to the owner by the mechanical contractor.
Project Title: Historymaker Homes Corporate Office Report date: 11/24/15
Data filename: H:\Jobs\2015\H15136 History Maker Homes\Engineering\Energy\COMcheck\Historymaker Mechanical
COMcheck Software • 4.0 .0
Interior • •' Compliance
Certificate
Section 1: Project Information
Energy Code: 2009 IECC
Project Title: Historymaker Homes Corporate Office
Project Type: New Construction
Construction Site: Owner/Agent: Designer/Contractor:
1038 Texan Trail Brian Allums, P.E.
Grapevine, TX 76051 HPMB Consulting Engineers, Inc
2828 E. Trinity Mills Rd. Ste 210
Carrollton, TX 75006
(214) 483-6202
Section 2: Interior Lighting and Power Calculation
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts / ft2 (B x C)
Office 28050 1 28050
Total Allowed Watts = 28050
Section 3: Interior Lighting Fixture Schedule
A
B
C
D
E
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
Lamps/
# of
Fixture
(C X D)
Fixture
Fixtures
Watt.
Office (28050 sq.ft.)
Linear Fluorescent 1: A1, A1X: Linear: 48" T8 32W: Electronic:
1
32
31
992
Linear Fluorescent 1 copy 1: A2, A2X: Linear: 48" T8 32W: Electronic:
2
57
59
3363
LED 1: B, BX: Linear: LED Linear 33W:
1
16
38
608
LED 2: C: Pendant: LED MR 8W:
1
9
8
72
LED 3: D1, D1X, DS,DW: Recessed Downlight: Other:
1
66
12
792
LED 1 copy 1: FX: Linear: Other:
1
3
70
210
Compact Fluorescent 1: G: Pendant: Triple 4 -pin 32W: Electronic:
1
66
35
2310
Compact Fluorescent 2: G2: Pendant: Triple 4 -pin 32W: Electronic:
1
8
35
280
LED 1 copy 2: H, HX: Linear: Other:
1
21
70
1470
Compact Fluorescent 3: M: Wall Sconce: Triple 4 -pin 32W: Electronic:
1
10
35
350
LED 6: N: LED Accent Strip: Other:
1
1
137
137
LED 7: T: Track Head: Other:
1
29
30
870
Total Proposed Wafts= 11454
Section 4: Requirements Checklist
In#erior Lighting PASSES: [design bg% fsetter than dodo,
Lighting Wattage:
1. Total proposed watts must be less than or equal to total allowed watts.
Allowed Watts Proposed Watts Complies
28050 11454 YES
Controls, Switching, and Wiring:
2. Daylight zones under skylights more than 15 feet from the perimeter have lighting controls separate from daylight zones adjacent to
vertical fenestration.
Project Title: Historymaker Homes Corporate Office Report date: 11/24/15
Data filename: H:\Jobs\2015\H15136 History Maker Homes\Engineering\Energy\COMcheck\Historymaker Lighting
L] 3. Daylight zones have individual lighting controls independent from that of the general area lighting.
Exceptions:
LJ Contiguous daylight zones spanning no more than two orientations are allowed to be controlled by a single controlling device.
❑ Daylight spaces enclosed by walls or ceiling height partitions and containing two or fewer light fixtures are not required to have a
separate switch for general area lighting.
Lj 4. Independent controls for each space (switch/occupancy sensor).
Exceptions:
L] Areas designated as security or emergency areas that must be continuously illuminated.
F-1 Lighting in stairways or corridors that are elements of the means of egress.
F -I 5. Master switch at entry to hotel/motel guest room.
Lj 6. Individual dwelling units separately metered.
U 7. Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent of the control
of the nonexempt lighting.
F-1 8. Each space required to have a manual control also allows for reducing the connected lighting load by at least 50 percent by either
controlling all luminaires, dual switching of alternate rows of luminaires, alternate luminaires, or alternate lamps, switching the middle
lamp luminaires independently of other lamps, or switching each luminaire or each lamp.
Exceptions:
L] Only one luminaire in space.
F-1 An occupant -sensing device controls the area.
L] The area is a corridor, storeroom, restroom, public lobby or sleeping unit.
F1 Areas that use less than 0.6 Watts/sq.ft.
F -I 9. Automatic lighting shutoff control in buildings larger than 5,000 sq.ft.
Exceptions:
L] Sleeping units, patient care areas; and spaces where automatic shutoff would endanger safety or security.
10. Photocell/astronomical time switch on exterior lights.
Exceptions:
[J Lighting intended for 24 hour use.
❑ 11.Tandem wired one -lamp and three -lamp ballasted luminaires (No single -lamp ballasts).
Exceptions:
L] Electronic high -frequency ballasts; Luminaires on emergency circuits or with no available pair.
Section 5: Compliance Statement
Compliance Statement. The proposed lighting design represented in this document is consistent with the building plans, specifications
and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2009 IECC
requirements in COMcheck Version 4.0.0 and to comply with the mandatory requirements in the Requirements Checklist.
Brian M. Allums, P.E. - Electrical Engineer
Name - Title
A11-24-15
Signature Date
Project Title: Historymaker Homes Corporate Office Report date: 11/24/15
Data filename: H:\Jobs\2015\H15136 History Maker Homes\Engineering\Energy\COMcheck\Historymaker Lighting COMcheck.cck Page 2 of 2
City of Grapevine
Building Inspection Department
Plan Review Comments
P.O. Box 95104 Phone: (817) 410-3129
Grapevine, Texas 76051 Fax: (817) 410-3536
NAME OF PROJECT: HISTORYMAKER HOMES
ADDRESS: 1038 TEXAN TRAIL
PLANS EXAMINER: ALLEN HUNT
NUMBER OF STORIES: 1 TOTAL SQ. FT: 28,050
ZONING: BP OCCUPANCY: B
OCCUPANT LOAD: EXITS REQUIRED: 3
FIRE SPRINKLED: YES BUILDING TYPE: VB
CU: 15-36
COMMENTS:
�1-1- EGRESS DOORS ARE TO BE OPENABLE FROM DIRECTION OF EGRESS
WITHOUT THE USE OF KEY, SPECIAL EFFORT OR KNOWLEDGE.
Understood. Additional notes have been added o A-641 D Schedule & Legend.
=� �'Aa
(2., MALINUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT
_" PERMITTED.
kUndeu, �ood. Additional notes have been added to A-641 Door Schedule & Legend.
P
:2j
PROJECT SHALL BE DESIGNED TO COMPLY WITH THE 2009 IECC.
Ir
VERIFICATION OF COMPLIANCE SHALL BE SUBMITTED TO THE CITY BY A
CERT flED ENERGY CODE INSPECTOR PRIOR TO THE ISSUANCE OF
BUILDING FINAL APPROVAL OR CERTIFICATE OF OCCUPANCY.
I. . ; a . A,
A 1
1:1 Wa k! [216*1111 M MA I 109:49 NMI
F-1 0 1 DIVI-1 DID] I I L•01 01 N 2 RWRE
<543/4 /633
COORDINATE ALL FIRE ALARM, SMOKE EVACUATION, AND / OR SPRINKLER
SYSTEM PLANS, APPROVALS AND INSPECTIONS WITH THE FIRE MARSHALL
AND REED ENGINEERING.
U 'stood.
6. PLANS THAT EXCEED 10 SHEETS WILL REQUIRE THAT ONE SET BE BOLTED.
Under oda
ALL MECHANICAL EQUIPMENT IS REQUIRED TO BE SCREENED FROM PUBLIC
VIEW. SCREENING TO INCLUDE ALL MECHANICAL EQUIPMENT ON SITE.
Understood. All Rooftop Units are screened and located so they are not visible from public
view'
ALL REQUIRED FLAT WORK FOR RIGHT OF WAY THAT IS ABSENT FROM SITE
WILL BE REQUIRED TO BE CONSTRUCTED. CONTACT PUBLIC WORKS
DEPARTMENT WHERE THIS WILL BE NECESSARY.
Under ood,
9 ALL CONSTRUCTION TO BE IN AGREEMENT WITH THE APPROVED
CONDITIONAL USE PLANS.
ZUnde ood.
10. SHEET A.0; PROVIDE THE FULL BUILDING DATA SHEET FOR THE PROJECT.
s •� s. r-- s r t -s * �
1 . SHEET A.113; GARAGE DOORS TO HAVE THE SAFETY, "EYES", TO PREVENT
CLOSING UPON AN OCCUPANT, PLEASE PROVIDE EXPLANATION FOR THE
DOORS OPERATION OR NON -OPERATION.
interiorf dividing garage doors operable •
requirea obstruction detectionensuredanger . closing,
with a mechanical system all safety features including electronic beam detection will be
incorporated.
_A�2.SHEET A.1 13; FOR THE FOLDING DOOR; 134-2, ENSURE THIS WILL MEET
WITH THE ENERGY CODE REQUIREMENTS WHEN IN THE OPEN POSISTION
WYOUR 3 ITH
R• PARTYREVIEW AND INSPECTIONS.
Verification will be pursued with the 3rd party review and inspection.
SHEET A.113; FOR THE GARAGE DOORS, WILL YOU PUTTING ANY
MECHANICAL DEVICES ABOVE GARAGE DOORS FOR AN AIR FAN / CURTAIN?
No mechanical devices or air fan or curtains will be placed above the garage doors shown
diving rooms.
Robert Lee
From: Albert Triplett <atriplett@grapevinetexas.gov>
Sent: Tuesday, January 05, 2016 4:43 PM
To: Robert Lee
Cc: Kevin Youngblood
Subject: RE: History Maker
Mr. Lee,
this looks great. Please send two full size copies of each sheet unfolded and
unbound. Thank you.
Albert L. Triplett Jr.
Planner II
City of Grapevine
200 S. Main Street
Grapevine TX 76051
817.410.3155
From: Robert Lee [
Sent: Tuesday, January 05, 2016 3:57 PM
To: Albert Triplett <atriplett@grapevinetexas.gov>
Cc: Kevin Youngblood <
Subject: RE: History Maker
Albert,
See attached PDF of the sheets in question. I have added the note with additional information just above the previous
signature block. Let me know if this meets with your approval or if you have any edits I need to make.
Robert Lee
Associate
500 West 7th Street, Suite 1400
Fort Worth, Texas 76102
817.335.4991 1www.k�bgtx.coin
From: Albert Triplett [mailto:atriplett grapevinetexas.gov]
Sent: Tuesday, January 05, 2016 3:39 PM
To: Robert Lee <
Subject: RE: History Maker
Thank you.
Albert L. Triplett Jr.
Planner II
City of Grapevine
1
200 S. Main Street
Grapevine TX 76051
817.410.3155
From: Robert Lee [mailto:
Sent: Tuesday, January 05, 2016 3:37 PM
To: Albert Triplett <atriplett a grapevinetexas.gov>
Subject: RE: History Maker
Albert,
I did receive your email and I am working on getting the Masonry & glazing numbers your requested. I will send
a PDF version to you for approval today.
Robert Lee
Associate
1i R
500 West 7th Street, Suite 1400
Fort Worth, Texas 76102
817.335.4991 i wvvw.bbptx com
From: Albert Triplett[mailto:atriplett@grapevinetexas.gov]
Sent: Tuesday, January 05, 2016 3:32 PM
To: Robert Lee <
Subject: Re: History Maker
Mr. Lee,
did you receive my email? Thank you.
Albert L. Triplett Jr.
Planner II
City of Grapevine
200 S. Main Street
Grapevine TX 76051
817.410.3155
POST-TENSION MATERIAL LIST
Quantity:
Lela th
Tag
Quitutity Len th , Ta "
24
140
LS 140
2 127 LB 127
14
140
LB 140
1 22 S22
8
143
LS 143
1 27 S27
7
104
5104
1 39 S39
6
114
5114
1 57 S57
4
100
5100
1 65 S65
4
104
B104
1 68 S68
4
106
S106
1 80 S80
4
143
LB143
1 87 S87
3
88
S88
1 99 S99
3
96
S96
1 123 LS 123
3
101
S101
1 125 LS125
3
109
5109
1 134 LS134
3
112
S112
3
115
S115
2
33
S33
2
33
B33
2
41
S41
2
41
B41
2
80
B80
2
88
B88
2
96
B96
2
99
B99
2
100
13100
2
101
13101
2
102
S102
2
103
S103
2
103
B103
2
107
S107
2
107
B107
2
109
B109
2
114
B114
2
115
B115
2
125
LB125
2
127
LS127
Totals:
Notes:
Strand
16379
1. This list is provided for estimating
Anchors/Wedges
294
purposes only. Verify all lengths
Grommets
206
and quantities prior to fabrication.
45° Grommets
2. All strands are single end stressed
Chairs
3300
unless noted otherwise.
Builder:
HISTORY MAKER HOMES,
Graham - Martin; ;ltd. , '
2100N H 360 Ste. 207A
Grandl'rairie`I 75050 `By:
Phone:(972) 647-1025 FAX (02)647 2630;
Date:
11/18/2015
Plan: HISTORY MAKER HOMES
Sq.Ft.:
14050
Lot: 2A
BG
Block: 2A
Checked:
Street:
ECKLEY STREET @ WALNUT ST
IGMI#
041658
Subdivision/ City:
GRAPEVINE STATION, GRAPEVINE
I Sheet 1
of 1
July 14, 2016
History Maker Homes
9001 Airport Fwy
North Richland Hills, TX 76180
Attn: Kevin Youngblood
Re: History Maker Homes Corp Office Framing Site Observation Report
Grapevine, TX
F)ATNA Project: #215545
Dear Mr. Youngblood:
Pursuant to your request we visited the subject project on the morning of Tuesday, July 12, 2016 in order to
observe the construction of the framing at its current state. Based upon my visual observations, the framing
appears to be constructed in general conformance with the construction documents.
If you need further assistance please consider us available.
Sincerely, '/ .
OF
C-)
...........
Frank W. Neal & Associates, Inc. RYAN W. L..........OCKHART
.... - .......... ...
Ryan W. Lockhart, PE 111552 .--ir
Principal
'CEN Se'D
r1ockhartafma-en-g.com ONACE
eE
'1016 W. Broadway Fax (817) 336-8620
Fort Worth, Texas 76104 fwna-eng.com
(M) 332-1944 TX Finn Reg. No. F000296
a
a,
ri
FWN, A
Frank W. Neal &Assoc., Inc.
November 7, 2016
History Maker Homes
4001 Airport Fwy
North Richland Hills, TX 76180
Attn: Kevin Youngblood
Re: History Maker Homes Corp Office Concurrence Letter
Grapevine, TX
FWNA Project: #215545
Dear Mr. Youngblood:
Pursuant to your request we visited the subject project multiple times during construction. Our visits included
observation of the pier construction, grade beam and slab construction, and steel and wood framing
construction. Based upon our observations the structure has been completed in general conformance with our
construction documents.
If you need further assistance please consider us available.
Sincerely,
.�` E � .
-lip
y •`
Frank W. Neal & Associates, Inc. RYAN W. LOCKHART
Ryan W. Lockhart, PF 11552
Principal �` .07
dockhart�3a Mna-eng.corn �
u000,296
Allen Hunt
To: Robert Lee; Kevin Youngblood
Subject: 1038 Texan Trail Bid. #1, Grapevine, Tx. New Commercial Building.
Gentlemen,
I have completed the revised plans review for the project. There are some items that have come to light that will need to
be addressed but I did not want to hold up the project for these so the plans are approved and all the other department
approvals are have been completed to issue the plans.
The primary needs for clarification concern the walls that are designed to be rated assembly's, the mechanical fire /
smoke dampers for penetration of these walls, the second floor mechanical chase and the exterior bearing walls headers
/ beams.
Please see sheets A111 and A121; the designs provide for rated enclosures at the stairwell #1 and the rooms adjoining
on the first level. These rated walls are not complete by the tag numbers and the stairwell is not rated at second level. If
this stairwell is rated for egress distance or other purpose the entire stairwell is to be rated. The rooms surrounding the
stairwell on first floor are incomplete. Please have designer clarify this area for rated assembly's and add ratings to the
elevator shaft, elevator equipment room and the duct chase'(s).
I do not see any fire / smoke dampers for the first floor system at deck or where penetrating chase walls, sheets M101
and M102. The other walls shown to be rated on first floor do not have all the dampers on plans if these walls are
indeed to be rated.
The mechanical chase running from deck to first level is in conflict with the second level file room.
I do not see the header / beam details for exterior walls at windows / doors.
The last item needing attention is sheet A-641, the door schedule. This sheet is not included on revised sets. Please
provide sheet to include correct ratings for doors that are opening protection for rated walls, hardware details,
comments that doors are openable from egress side without use of key, special effort or knowledge and other details
included within the door schedules.
I believe this covers the primary elements still needed for the plans. Please include any other details as needed.
Thank you,
Allen Hunt
Plans Examiner/ Field Coordinator
City of Grapevine
817-410-3129
2100 N. Hwy 360, Suite 207A
Grand Prairie, TX 75050
(972) 647-1025 / (972) 647-2630 Fax
September 23, 2015
History Maker Homes, LLC.
9001 Airport Freeway, #400
North Richland Hills, TX 76180
Re: Lot 2A Block 2A
Eckley Street @ Walnut Street
Grapevine Station, Grapevine
Plan: History Maker Office Bldg.
GML# 041658
To Whom it May Concern:
Engineering Consultants
Texas Reg. Eng. Firm F-8336
The foundation for the above referenced location has been designed and evaluated in
accordance with the latest recommendations as set forth by the Post -Tensioning Institute's
publication: Design and Construction of Post -Tensioned Slabs on Ground. It has also been
designed in accordance with the current 1997 Uniform Building Code, the 2006, 2009 and
2012 International Residential Codes, the 2006, 2009 and 2012 International Building
Codes, and standard engineering practices. The pertinent soils information utilized in the
design was obtained from the following geo-technical investigation:
Report by:
Alpha Testing
Report #:
G151668
Dated:
8/19/2015
EmCI:
8.3'
Qa:
1500
EmEI:
4.2'
PI:
31
YmCI:
1.3"
PVR:
6"*
YmEI:
1.8"
,. 0 I �t ,
Sincerely, ®All F yl t,
GRAN -MARTIN, LTD .►. s
.. :�
.. .......
if-- BILL GRAHAM
.................................
t � 67899 w�
BiII Graham, P.E. `
=fir
Principal t!'1igoNA� �e�
Allen Hunt
To:
Subject: 1038 Texan Trail new commercial building HistoryMaker Homes
Attachments: 1038 TEXAN TRAIL plan review comments-cloc
Mr. Lee,
I have reviewed the plans for the above project and have attached the comments to this e-mail. Please review
comments and have your designers create revisions with all the changes, additions, corrections and / or commentary as
needed.
Many of the comments I have put down can be taken care by red lining the plan but please see comments 10-21 for
what is needed to clarify, correct and / or add to the plans.
Thank you,
Allen Hunt
Plans Examiner/ Field Coordinator
City of Grapevine
817-410-3129
City of Grapevine
i
P.O. Box 95104 Phone: (817) 410-3129
Grapevine, Texas 76051 Fax: (817) 410-3536
NAME OF PROJECT: HISTORYMAKER HOMES
ADDRESS: 1038 TEXAN TRAIL
PLANS EXAMINER: ALLEN HUNT
NUMBER OF STORIES: 1
ZONING: BP
OCCUPANTLOAD:
FIRE SPRINKLED: YES
CU: 15-36
COMMENTS:
TOTAL SQ. FT: 28,050
OCCUPANCY: B
EXITS REQUIRED: 3
BUILDING TYPE: VB
1. ALL EGRESS DOORS ARE TO BE OPENABLE FROM DIRECTION OF EGRESS
WITHOUT THE USE OF KEY, SPECIAL EFFORT OR KNOWLEDGE.
2. MAUNUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT
PERMITTED.
3. PROJECT SHALL BE DESIGNED TO COMPLY WITH THE 2009 IECC.
VERIFICATION OF COMPLIANCE SHALL BE SUBMITTED TO THE CITY BY A
CERTIFIED ENERGY CODE INSPECTOR PRIOR TO THE ISSUANCE OF
BUILDING FINAL APPROVAL OR CERTIFICATE OF OCCUPANCY.
4. ALL CHANGES FROM THE CITY APPROVED PLANS WILL REQUIRE REVISED
PLANS SUBMITTED AND ADDITIONAL FEES DUE.
5. COORDINATE ALL FIRE ALARM, SMOKE EVACUATION, AND / OR SPRINKLER
SYSTEM PLANS, APPROVALS AND INSPECTIONS WITH THE FIRE MARSHALL
AND REED ENGINEERING.
6. PLANS THAT EXCEED 10 SHEETS WILL REQUIRE THAT ONE SET BE BOLTED.
7. ALL MECHANICAL EQUIPMENT IS REQUIRED TO BE SCREENED FROM PUBLIC
VIEW. SCREENING TO INCLUDE ALL MECHANICAL EQUIPMENT ON SITE.
8. ALL REQUIRED FLAT WORK FOR RIGHT OF WAY THAT IS ABSENT FROM SITE
WILL BE REQUIRED TO BE CONSTRUCTED. CONTACT PUBLIC WORKS
DEPARTMENT WHERE THIS WILL BE NECESSARY.
22. PLEASE READ THE FOLLOWING NOTE CAREFULLY AND FOLLOW THE
INSTRUCTIONS GIVEN. PLANS WILL NOT BE ACCEPTED THAT ARE REVISED
AND DO NOT FOLLOW THESE REQUIREMENTS, THANK YOU.
Please review comments and have designers add all review comments, required
Information and created changes, all clouded within new plan sets. Please
Provide 3 copies of new fully corrected plan sets. Plan size may not exceed 36"x
42" in dimension.
Provide one set to city that is bolted if plans are over 10 pages. Thank you for your
Time and consideration.
APPLICATION RECEIVED: 1ST COMMENTS:
REVISIONS RECEIVED: REVISIONS REVIEWED:
PERMIT ISSUED:
m
0
JAN 5 2017
-SITE PLAN - LIGHTING LEVELS
ELECTRICAL LEGEND
FOOTCANDLE READING GRADE LEVEL PLANAR POINT OF MEASUREMENT
FOOTCANDLE LIGHTING LEVEL. NUMBER INDICATES FC LEVEL.
LIGHT STANDARD, REFER TO NOTES BY SYMBOL FOR FIXTURE DESCRIPTION
F_ 'ERIE L NOTES
I. SITE LIGHTING CONSIST OF TWO TYPES OF POLE MOUNTED LIGHT FIXTURES.
ONE TRADITIONAL LIGHT STANDARD AND ONE DECORATIVE .AREA LIGHT.
2.'THERE ARE NO BUILDING MOUNTED LUMINAIRES CONTRIBUTING TO THE OVERALL
FOOTCANDLE MEASUREMENTS.
3, ADJACENT PROPERTIES HAVE NO SITE LIGHTS WITHIN 100' OF PROPERTY LINE.
NOTES BY SYMBOL '10'
17,218 LUMEN LED LIGHT STANDARD AREA LIGHT (20' ABOVE FINISHED GRADE),
3,036 LUMEN LED DECORATIVE AREA LIGHT (20' ABOVE FINISHED GRADE).
GRADE LEVEL FOOTCANDLE READING TAKEN AT BASE OF LIGHT POLE.
FOOTCANDLE READING GRADE LEVEL PLANAR POINT OF MEASUREMENT
WESTERN PROPERTY LINE IS ACTUALLY TBEYOND AN 8' HIGH MASONRY WALL.
FC READINGS ARE TAKEN AT THE MASONRY WALL WELL WITHIN THE PROP- LINE,
NORTHPROPERTY LINE IS APPROXIMATE AS BOTH PARCELS ARE OWNED BY THE
SAME ENTITY. FC READINGS ARE TAKEN AT 25' BEYOND FIXTURE LOCATIONS IN AN
OPEN FIELD.
F rim r
CONSULTANTS, I NC.
Texas BPE Registration # F-207
1300 Summit
Awme 4144 N. Central Expwy
S.h. 500 Suits 635
Fon Worth, Texas 78102 Dallas, Tens 75204
01817 878 4242 Offloe 214 420 9111
Facsimile 817 878 4240 --it—P.-
CONSTRUCTION
DOCUMENTS
Project No: 15117,00
Issue Date: 11-25-2015
Rev. Description Date
666
1-01
E
CL
00
F rim r
CONSULTANTS, I NC.
Texas BPE Registration # F-207
1300 Summit
Awme 4144 N. Central Expwy
S.h. 500 Suits 635
Fon Worth, Texas 78102 Dallas, Tens 75204
01817 878 4242 Offloe 214 420 9111
Facsimile 817 878 4240 --it—P.-
CONSTRUCTION
DOCUMENTS
Project No: 15117,00
Issue Date: 11-25-2015
Rev. Description Date
666
7 PZA_ N
LIGHTING LEVELS