Loading...
HomeMy WebLinkAboutCU2026-22Light Industrial District Planned Industrial Development District R-TH Townhouse District S H 3 6 0 N B K O D I AK CT S H 3 6 0 F R N B EU L E S S - G R A P E V I N E R D 3401 KODIAK CT 601 WESTPORT PKWY 625 WESTPORT PKWY 3257 STATE HWY 360 4201 STATE HWY 360 1500 E STATE HWY 114 3337 KODIAK CT 3349 KODIAK CT 3345 KODIAK CT 3353 KODIAK CT 3357 KODIAK CT 3365 KODIAK CT 3361 KODIAK CT 3301 KODIAK CT 3305 KODIAK CT 3309 KODIAK CT 3313 KODIAK CT 3317 KODIAK CT 3321 KODIAK CT 3325 KODIAK CT 3329 KODIAK CT 3333 KODIAK CT 3642 EULESS-GRAPEVINE RD CU26-22; DynaTen Improvements SUBJECT PROPERTY This data has been compiled by the City of Grapevine IT/GIS department. Various official and unofficial sources were used to gather this information. Every effort was made to ensure the accuracy of this data, however, no guarantee is given or implied as to the accuracy of said data.0 50 100150200 Feet Date Prepared: 7/27/2026 2026 NEARMAP IMAGERY Subject Property: 3642 Euless-Grapevine Road CU26-22 – 1st Review Memo 1 Email a PDF of the revised plans by July 21, 2026 at 12:00 p.m. to lflores@grapevinetexas.gov/atriplett@grapveinetexas.gov/mhassan@grapevinetexas.g ov/emarohnic@grapevinetexas.gov. Verify that all text is legible on an 11”x 17” sheet. Do not reproduce final copies requested below prior to Planning Staff approval. PROJECT DESCRIPTION: CU26 -2 2 ; Dyna T en Improvements – submitted by Evan Zhao with Arco/Murray National Dallas for property located at 3642 Euless - Grapevine Road and platted as Block 1, Lot 4 , Curnes Addition . The applicant is requesting a conditional use permit to amend the previously approved building elevations (CU25 -4 6 ) to allow four (4) additional windows along the e ast elevation and two (2) trailer doors along the west elevation of the existing building . The property is currently zoned “PID ”, Planned Industrial Development District and owned by DFW West Logistics One , LLC. PLANNING SERVICES Dimensional Control Site Plan • Update preparation date in title block. • Legal description should say “CUNRES ADDITION” (not Swanson). o Correct case name to DYNATEN IMPROVEMENTS and case number to CU26-22 on approval block CU26-22 JULY 16, 2026 DYNATEN IMPROVEMENTS 3642 EULESS-GRAPEVINE ROAD BLOCK 1, LOT 4, CURNES ADDITION Site Plan/Landscape Plan/Photometric Plan/Façade Plan (example) for The Grapevine Brownstones Lot X-Y, Block X, SUBDIVISION NAME Ab. No. ZZZ City of Grapevine, Tarrant County, Texas X.X acres or XX sq. ft. Zone: “LI” Light Industrial, proposed Transit District Overlay Date of Preparation: January 17, 2022 (or subsequent date or revision) CU26-22 – 1st Review Memo 2 • Revise purpose statement to accurately reflect proposed scope (four (4) additional windows on the east elevation and two (2) trailer doors on the west elevation). • Previously approved improvements should not be included in scope. Remove clouds around gate/fence at the northwest corner of the building and the covered parking along the east side of the building. Also, remove “PROP.” from the fence/gate label at the northwest corner. Building Elevations – Sheet #A5.1.1 • Remove construction details from elevation drawings. Focus on an easily digestible, architectural presentation of the elevations. • Add approval block to the lower right-hand corner of the page. Floor Plan – Sheet #A2.1.1 • Remove construction details from floor plan drawings. Focus on an easily digestible, architectural presentation of the plan, with applicable dimensions shown. • Add approval block to the lower right-hand corner of the page. Window Schedule – Sheet #A4.5.1 • Does not need to be included in the conditional use permit request. Narrative Letter • Scope of request should include the four (4) additional windows along the east elevation and the 2 trailer doors along the west elevation (in place of the overhead garage door). • Remove the fence/gate and covered parking from the scope request as they have already been approved. PUBLIC WORKS Contact Paul Lee - Civil Engineer or Elizabeth Reynolds – Engineering Manager at 817.410.3000 for the following comments: • No Comments BUILDING SERVICES Contact Arnoldo Ramirez – Building Official at 817.410.3160 or arnoldor@grapevinetexas.gov to discuss the following: • No Comments FIRE MARSHALL Contact Sam Daniel - Fire Marshal at 817.410.4421 or sdaniel@grapevinetexas.gov for the following comments: CU26-22 – 1st Review Memo 3 • No Comments PARKS Contact Kathy Nelson – Capital Improvements Program Manager at 817.410.3394 or knelson@grapevinetexas.gov to discuss the following: • No Comments ______________________________________________________________ Email a PDF of the revised final plans by July 21, 2026, at 12:00 p.m. to atriplett@grapveinetexas.gov/mhassan@grapevinetexas.gov/lflores@grapevinetexas.g ov/emarohnic@grapevinetexas.gov. Verify that all text is legible on an 11”x 17” sheet. Do not reproduce final copies requested below prior to Planning Staff approval. Please direct all questions to Mona Hassan at (8l7) 410-3155 or Albert Triplett at (817) 410-3151. 555 560 5 6 5 5 7 0 553 554 556 5 5 7 558 559 56 1 5 6 2 5 6 3 5 6 4 5 6 6 5 6 7 5 6 8 5 6 9 5 7 1 5 7 2 5 6 0 56 0 557 558 558 55 9 559 561 56 156 2 56 2 55 8 55 9 55 8 55 9 55 8 55 9 55 8 55 9 565 561 562 563 564 56 6 5 6 5 5 6 2 5 6 3 5 6 4 5 6 6 5 6 7 5 6 8 5 6 9 5 6 5 5 6 2 5 6 3 5 6 4 563 564 5 6 1 5 6 2 5 6 3 560561 56 2 56 2 56 2 56 3 5 6 2 56 2 56 3 575 57 2 57 3 57 4 57 3 5 7 3 5 7 4 56 2 56 3 562 563 5 6 0 558 559 5 6 1 5 6 2 5 6 0 5 6 1 5 6 2 5 6 3 561 562 563 565564 566 567 570569 571 572 573 574 565 570 564 566567568569 571 56 0 56 5 55 956 1 56 2 56 3 56 4 5 6 6 560 5 6 5 55 6 55 7 55 8 559 561 562 56 3 56 4 566 5 5 8 5 5 1 5 4 0 5 4 5 55 0 5 4 1 5 4 2 5 4 3 5 4 4 5 4 6 5 4 7 5 4 8 5 4 9 54 0 54 5 550 55 5 560 54 1 54 2 54 3 54 4 546 547 548 549 55 1 55 2 55 3 55 4 556 55 7 558 55 9 561 562 563 56 0 56 1 56 2 56 3 562 563 560 558 559 561 561 561 562 54 8 547 540 54 5 5 3 9 541 542 543 54 4 54 6 560 556 557 558 559 561 562 5 6 2 5 6 2 56 3 56 5 56 2 563 56 4 56 6 5 7 0 56 7 56 8 56 9 18 " R C P 18 " R C P 18 " R C P FIRE FIREFIREFIRE F I R E FI R E FI R E FI R E FI R E FI R E FI R E FI R E FI R E FIR E FIRE FIRE FIRE FIRE FIREFIREFIRE FI R E FI R E FI R E FI R E FI R E FI R E FI R E FI R E FIR E FIRE FIRE FIRE FI R E FI R E FI R E FI R E FI R E FI R E FI R E FI R E FI R E FI R E FI R E FI R E FI R E FI R E FI R E FI R E Ex O H E Ex O H E Ex O H E Ex O H E Ex O H E Ex O H E Ex O H E Ex 1 2 i n W Ex 1 2 i n W Ex 1 2 i n W Ex 1 2 i n W Ex 1 2 i n W Ex 1 2 i n W Ex 3 3 i n S D Ex 3 3 i n S D Ex 3 3 i n S D Ex 3 3 i n S D Ex 3 6 i n S D CO CO CO Ex 8in SS Ex 8in SS Ex 8 i n S S Ex 8 i n S S Ex 12in W Ex 12in W Ex 12in W Ex 12in W Ex 1 2 i n W Ex 1 2 i n W Ex 1 2 i n W Ex 1 2 i n W Ex 1 2 i n W Ex 12in W Ex 12in W Ex 12in W Ex 2 i n W Ex 2 i n W EX 2 4 " R C P EX 1 8 " R C P EX 1 8 " R C P EX 2 4 " R C P EX 2 4 " R C P EX 18" RCP EX 2 4 " R C P EX 3 6 " R C P EX 3 6 " R C P EX 48" RCP EX 1 8 " R C P EX 3 6 " R C P EX 36" RCP EX 4 8 " R C P EX 1 8 " R C P EX I S T . 2 4 ' F I R E L A N E PROP. ~104 LF RETAINING WALL PROP. GATE PROP. GATE 5' SIDEWALK R 20.0' EXIST. 6' WOOD FENCE EU L E S S - G R A P E V I N E R D (V A R I A B L E W I D T H R O W ) VARIABLE WIDTH ROW VARIABLE WIDTH ROW EXIST. 50' ROAD PROPERTY LINE EXIST. 24" STORM DRAIN EU L E S S - G R A P E V I N E R D (V A R I A B L E W I D T H R O W ) PROP. STORM DRAIN PROP. STORM DRAIN PROP. STORM DRAIN 18.0'24.0'18.0' 24 . 0 ' 9. 0 ' 18 . 0 ' 9. 0 ' 90 . 0 ' 9. 0 ' 90 . 0 ' 9. 0 ' 81 . 0 ' 34 . 0 ' 90 . 0 ' 9. 0 ' 90 . 0 ' 9. 0 ' 10 8 . 0 ' 9. 0 ' 27 . 0 ' 18.0' 15 . 0 ' 2' FLUME (TYP.) 9. 0 ' (T Y P . ) 18.0'24.0'18.0'18.0' 36 . 0 ' 48.4' N0 0 ° 3 1 ' 1 5 " W 18 2 0 . 6 3 ' N89°52'32"E 732.56' S0 0 ° 3 2 ' 5 6 " E 17 5 6 . 1 6 ' EXIST. 10' WATER EASEMENT 265.0' EXISTING BUILDING (200,340 SF) FFE = 563.50' MIN. FFE = 539.50' 30 . 0 ' 2 3 10 10 10 10 9 9 10 10 1010 12 9 4 2 2 2 2 4 5 6 3 9 9 9 EXIST. DOCK RAMP EXIST. 10' WATER EASEMENT EXIST. 10' WATER EASEMENT EXIST. ACCESSIBLE PARKING PROP. DOCK RAMP EXIST. DOCK RAMP 75 6 . 0 ' EXIST. ACCESSIBLE PARKING EXIST. ACCESSIBLE PARKING EXIST. ACCESSIBLE PARKING 30' FRONT YARD SETBACK EXIST. 10' WATER EASEMENT EXIST. SCREEN WALL EXIST. SCREEN WALL EXIST. TRAILER PARKING EX I S T . 6 0 . 0 ' DR I V E W A Y EX I S T . 5 0 . 0 ' DR I V E W A Y EXIST. 4.7' SIDEWALK EXIST. BARRIER FREE RAMP EXIST. BARRIER FREE RAMP EXIST. BARRIER FREE RAMP EXIST. BARRIER FREE RAMP EXIST. 4.7' SIDEWALK 30' REAR YARD SETBACK 15' YARD SETBACK 50' BUILDING SETBACK EXIST. 10' UTILITY EASEMENT EXIST. 12" PRIVATE WATER LINE EXIST. 8" SANITARY SEWER EXIST. 12" PUBLIC WATER LINE EXIST. FIRE HYDRANT EXIST. FIRE HYDRANT EXIST. FIRE HYDRANT EXIST. FIRE HYDRANT EXIST. FIRE HYDRANT EXIST. RETAINING WALL EXIST. RETAINING WALL EXIST. STORM DRAIN EXIST. STORM DRAIN EXIST. STORM DRAIN EXIST. GUARDRAIL WATERS OF THE U.S. PROP. 8' WROUGHT IRON SECURITY FENCE PROP. 8' WROUGHT IRON SECURITY FENCE 9 9 2 9 8 9 12 EXIST. FIRE HYDRANT PROP. 8' CHAIN LINK FENCE PROP. GATE1 PROP. DOCK RAMP SIX (6) COVERED PARKING SPACES 54 . 0 ' 2 9 20.0'177.0' 10.0' 0 SCALE IN FEET 25 50 100 LEGEND NOTES: 1.ALL DIMENSIONS ARE TO FACE OF CURB UNLESS STATED OTHERWISE NOTED. 2.ALL CURBS ARE 6" UNLESS NOTED OTHERWISE. 3.BUILDING TO BE USED AS AN INDUSTRIAL WAREHOUSE AND OFFICE. THE INFORMATION SHOWN ON THESE DRAWINGS INDICATING SIZE, TYPE AND LOCATION OF UNDERGROUND, SURFACE, AND AERIAL UTILITIES IS NOT GUARANTEED TO BE EXACT OR COMPLETE. THE CONTRACTOR SHALL CONTACT THE "TEXAS 811" SYSTEM AT 1-800-344-8377 (DIG TESS) 48 HOURS PRIOR TO BEGINNING ANY EXCAVATION FOR EXISTING UTILITY LOCATIONS. THE CONTRACTOR SHALL ALSO BE FULLY RESPONSIBLE FOR FIELD VERIFYING LOCATIONS AND ELEVATIONS OF ALL EXISTING UTILITIES AFFECTED BY CONSTRUCTION FOR THIS PROJECT IN ORDER TO AVOID DAMAGING THOSE UTILITIES, AND SHALL IMMEDIATELY ARRANGE FOR REPAIR AND RESTORATION OF CONTRACTOR-DAMAGED UTILITIES TO THE UTILITY COMPANY'S APPROVAL AT THE EXPENSE OF THE CONTRACTOR. Know what'sbelow. before you dig.Call R 6" THICK, 4,000 PSI CONCRETE PAVEMENT WITH #3 BARS AT 18" O.C.E.W. OVER 95% COMPACTED NATIVE 5" THICK, 4,000 PSI CONCRETE PAVEMENT WITH #3 BARS AT 18" O.C.E.W. OVER 95% COMPACTED NATIVE 4" THICK, 4,000 PSI CONCRETE PAVEMENT WITH #3 BARS AT 24" O.C.E.W. PROP. FENCE TRAFFIC CIRCULATION PLAN PROPERTY LINE TYPICAL PARKING COUNT ACCESSIBLE PARKING COUNT PROP. CURB INLET PROP. STORM DRAIN PIPE CO EXIST. WATER LINE EXIST. SANITARY SEWER LINE EXIST. STORM DRAIN PIPE (ONSITE) EXIST. STORM DRAIN PIPE (OFFSITE) EXIST. FIRE HYDRANT EXIST. WATER METER EXIST. SANITARY SEWER MANHOLE EXIST. CLEAN OUT EXIST. GRATE INLET EXIST. CURB INLET EXIST. STORM JUNCTION BOX EXIST. Y-INLET Ex 8in W Ex 8in SS Ex 24in SD 2 9 06/26/2026 FI L E N A M E : A: \ 4 5 0 0 0 s \ 4 5 2 4 4 \ 0 0 3 \ L D \ C A D D \ S h e e t s \ S P - S I T E - 4 5 2 4 4 . 0 0 3 . d w g D A T E : Ju n e 2 6 , 2 0 2 6 , T I M E : 1: 3 3 P M , U S E R : ah 3 1 9 3 CASE NAME: DYNATEN FINISH OUT CASE NUMBER: CU25-46 LOCATION: 3642 EULESS-GRAPEVINE ROAD MAYOR DATE: SHEET: OF 3 APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH ANY CODES OR ORDINANCES. PLANNING SERVICES DEPARTMENT for LOT 4, BLOCK 1, SWANSON ADDITION Catherine Clanton Survey, Abstract 354 City Of Grapevine, Tarrant County, Texas 30.57 Acres Zone:PID, Planned Industrial Development Date of Preparation: June 26, 2026 PLANNING AND ZONING COMMISSION SECRETARY CHAIRMAN PURPOSE STATEMENT: CONDITIONAL USE PERMIT CU25-46 IS A REQUEST FOR CONDITIONAL USE PERMIT IS TO ALLOW OUTDOOR STORAGE IN CONJUNCTION WITH THE PARKING EXPANSION TO AN EXISTING INDUSTRIAL WAREHOUSE BUILDING. STANDARD NOTES: 1.REFUSE DISPOSAL AREAS SHALL BE LANDSCAPED AND SCREENED FROM VIEW IN ACCORDANCE WITH THE ZONING ORDINANCE. 2.MECHANICAL AND ELECTRICAL EQUIPMENT INCLUDING AIR CONDITIONING UNITS, SHALL BE DESIGNED, INSTALLED, AND OPERATED TO MINIMIZE NOISE IMPACT ON SURROUNDING PROPERTY. ALL SUCH EQUIPMENT SHALL BE SCREENED FROM PUBLIC VIEW IN ACCORDANCE WITH THE ZONING ORDINANCE. 3.OPEN STORAGE, WHERE PERMITTED, SHALL BE SCREENED IN ACCORDANCE WITH THE ZONING ORDINANCE. 4.THE MASONRY REQUIREMENTS OF SECTION 54 OF THE ZONING ORDINANCE SHALL BE MET. 5.ILLUMINATED SIGNAGE WAS INCLUDED IN THE DETERMINATION OF THE SITE ILLUMINATION LEVELS. 6.OUTDOOR LIGHTING SHALL COMPLY WITH ILLUMINATION STANDARDS WITHIN SECTION 55 OF THE ZONING ORDINANCE UNLESS SPECIFICALLY EXCEPTED. 7.PROPOSED GROUND SIGNAGE SHALL MEET THE MINIMUM REQUIREMENTS OF SECTION 60 OF THE ZONING ORDINACE AND IS CONTINGENT UPON APPROVAL OF A SEPARATE BUILDING PERMIT WITH BUILDING SERVICES. 8.ALL ONSITE ELECTRICAL CONDUCTORS ASSOCIATED WITH NEW CONSTRUCTION SHALL BE LOCATED UNDERGROUND. 9.USES SHALL CONFORM IN OPERATION, LOCATION, AND CONSTRUCTION TO THE FOLLOWING PERFORMANCE STANDARDS IN SECTION 55 OF THE ZONING ORDINANCE: NOISE, SMOKE AND PARTICULATE MATTER, ODOROUS MATTER, FIRE OR EXPLOSIVE HAZARDS MATERIAL, TOXIC AND NOXIOUS MATTER, VIBRATION, AND/OR OTHER PERFORMANCE STANDARDS. 10.ALL REQUIREMENTS OF THE CITY OF GRAPEVINE SOIL EROSION CONTROL ORDINANCE SHALL BE MET DURING THE PERIOD OF CONSTRUCTION. PROJECT LOCATION VICINITY MAP OWNER CURNES PARTNERS, LP CONTACT: BUNKER CURNES TEL: 214-600-3057 EMAIL: BUNKERCURNES@GMAIL.COM CONTRACTOR ARCO MURRAY CONTACT: CHASE KILLINGSWORTH TEL: 469-251-9017 EMAIL: CKILLINGSWORTH@ARCOMURRAY.COM ENGINEER HALFF ASSOCIATES CONTACT: KAITLYNN E. CLOUGH TEL:817-847-1422 EMAIL: KCLOUGH@HALFF.COM ARCHITECT GMA ARCHITECTS CONTACT: MICHAEL YOUNG TEL: 317-835-3421 EMAIL: MYOUNG@GMA-ARCHITECTS.COM ELECTRICAL ENGINEER ARCO MURRAY ENGINEERING CONTACT: JOE BUSHMAN TEL: 331-998-3341 EMAIL: JBUSHMAN@ARCOMURRAY.COM FOR SITE PLAN REVIEW ONLY. NOT FOR CONSTRUCTION. NOT TO SCALE DIMENSION CONTROL SITE PLAN 1 OVERHEAD DRIVE-IN DOOR - SEE DOOR SCHEDULE FOR ADDITIONAL INFORMATION INSULATED GLAZING IN PRE-FINISHED STOREFRONT FRAME. SEE WINDOW TYPES FOR MORE INFORMATION. 1 2 ELEVATION KEYNOTES ELEVATION GENERAL NOTES 1.HEIGHT OF ALL WALLS, ROOFS, AND PARAPETS SHOWN ON ELEVATIONS ARE TAKEN FROM THE BUILDING FINISH FLOOR (ELEVATION 100'-0"). 2.ALL ELEVATION HEIGHTS ARE SHOWN TO TOP OF CONCRETE PANEL / BOTTOM OF WOOD BLOCKING. 3.VERIFY GRADES AND BUILDING LINE WITH CIVIL DRAWINGS. 4.PAINT ALL EXTERIOR ELECTRICAL EQUIPMENT, BOXES, AND CONDUIT TO MATCH ADJACENT WALL SURFACE. 5.DO NOT PAINT ANY EXTERIOR PREFINISHED MATERIAL. 6.GENERAL CONTRACTOR TO VERIFY AND COORDINATE ALL DOCK EQUIPMENT AND SIGNAGE WITH OWNER. Q AKJHGFEDCBLMNP 1 5432 6 QLMNPAKJHGFEDCB 154326 WEST ELEVATION4 A5.1.1 SCALE: 1" = 30'-0" EAST ELEVATION2 A5.1.1 SCALE: 1" = 30'-0" NORTH ELEVATION1 A5.1.1 SCALE: 1" = 30'-0" SOUTH ELEVATION3 A5.1.1 SCALE: 1" = 30'-0" T.O. CONCRETE B.O. WD. BLOCKING EL. 139'-0" FIN. FLOOR EL. 100'-0" T.O. CONCRETE B.O. WD. BLOCKING EL. 146'-0" FIN. FLOOR EL. 100'-0" T.O. CONCRETE B.O. WD. BLOCKING EL. 110'-0" T.O. CONCRETE B.O. WD. BLOCKING EL. 140'-0" T.O. CONCRETE B.O. WD. BLOCKING EL. 141'-0" T.O. CONCRETE B.O. WD. BLOCKING EL. 142'-0" T.O. CONCRETE B.O. WD. BLOCKING EL. 143'-0" T.O. CORNICE EL. 146'-6" T.O. CONCRETE B.O. WD. BLOCKING EL. 146'-0" FIN. FLOOR EL. 100'-0" T.O. CONCRETE B.O. WD. BLOCKING EL. 146'-0" FIN. FLOOR EL. 100'-0" T.O. CORNICE EL. 146'-6" T.O. CORNICE EL. 146'-6" T.O. CORNICE EL. 146'-6" T.O. CONCRETE B.O. WD. BLOCKING EL. 144'-0" T.O. CONCRETE B.O. WD. BLOCKING EL. 144'-0" T.O. CONCRETE B.O. WD. BLOCKING EL. 146'-0" T.O. CONCRETE B.O. WD. BLOCKING EL. 140'-0"T.O. CONCRETE B.O. WD. BLOCKING EL. 139'-0" FIN. FLOOR EL. 100'-0" T.O. CONCRETE B.O. WD. BLOCKING EL. 141'-0" T.O. CONCRETE B.O. WD. BLOCKING EL. 142'-0" T.O. CONCRETE B.O. WD. BLOCKING EL. 143'-0" T.O. CONCRETE B.O. WD. BLOCKING EL. 146'-0" FIN. FLOOR EL. 100'-0" T.O. CORNICE EL. 146'-6" T.O. CONCRETE B.O. WD. BLOCKING EL. 110'-0" T.O. CONCRETE B.O. WD. BLOCKING EL. 139'-0" FIN. FLOOR EL. 100'-0" DOCK APRON EL. 96'-0" T.O. CONCRETE B.O. WD. BLOCKING EL. 139'-0" FIN. FLOOR EL. 100'-0" DOCK APRON EL. 96'-0" 2 2 2 2 2 2 2 2 1 1 A A A A A A A A 1 2 2 A 2 A 2 A 2 A A5.1.1 OVERALL EXTERIOR ELEVATIONS SHEET NUMBER DRAWN BY: ISSUE DATE: REVISIONS:# DY N A T E N - S H E L L I M P R O V E M E N T S THIS DESIGN AND THESE DRAWINGS ARE THE PROPERTY OF GMA ARCHITECT, INC. NO PART OF THIS WORK MAY BE REPRODUCED WITHOUT PRIOR WRITTEN PERMISSION FROM GMA ARCHITECTS, INC. AHT 02.24.2026 PR O J E C T : CIVIL HALFF ASSOCIATES, INC. 1201 NORTH BOWSER ROAD RICHARDSON, TX 75081 P: 214-346-6200 7930 CLAYTON ROAD, SUITE 300 RICHMOND HEIGHTS, MO 63117 P: (314) 822-5191 WWW.GMA-ARCHITECTS.COM 4849 GREENVILLE AVE. SUITE 1460 DALLAS, TX 75206 P: (214) 377-6681 WWW.ARCOMURRAY.COM 36 4 2 E U L E S S - G R A P E V I N E R O A D GR A P E V I N E , T X 7 6 0 5 1 06.25.2026 ARCO JOB NO:D249 GMA JOB NO:GA1997 STRUCTURAL RICHARD ADAMS ENGINEERS 5507 EAST BUSCH BLVD TEMPLE TERRACE, FLORIDA 33617 P: 813-985-4600 06.25.20 2 6 REV #1 |04.02.2026 REV #2 |06.25.2026 1 2 1.CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS AT THE JOB SITE AND NOTIFY ARCHITECT OF ANY OMISSIONS, DISCREPANCIES, AND/OR CONFLICTS BEFORE PROCEEDING WITH THE WORK. 2.ALL BOLLARDS SHALL BE PAINTED. 3.GLAZING AND FRAME SUPPLIERS SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION. DRIVE-IN DOOR. SEE DOOR SCHEDULE FOR ADDITIONAL INFORMATION. SEE 4/A4.4.1 FOR BOLLARD PLACEMENT / INFORMATION. STOREFRONT SYSTEM AS SCHEDULED. SEE WINDOW TYPES ON A4.5.1 AND EXTERIOR ELEVATIONS. XXX X FLOOR PLAN GENERAL NOTES FLOOR PLAN KEYNOTES FLOOR PLAN LEGEND DOOR TAG WINDOW TAG EXISTING DOOR TO REMAIN OVERALL FLOOR PLAN1 A2.1.1 SCALE: 1" = 30'-0" 2 1 6 3 4 5 A QBCDEFGHJKLMNP W100A W100C 22'-6" 2'-3" 22'-6" 2'-3" 5'-6" 6'-2" 5'-6" 9'-0" 3'-8" 9'-0" 3'-4"5'-6" 8'-4"9'-0" 5'-6"5'-6" 6'-2"9'-0" 5'-6" 6'-2" 1'-10"4" 5'-2" 1 1 2 A A A A A A A A 2222222 756'-0" 54'-0" 26 5 ' - 0 " 60 ' - 0 " 54'-0"54'-0"54'-0"54'-0"54'-0"54'-0"54'-0"54'-0"54'-0"54'-0"54'-0"54'-0"54'-0" 51 ' - 3 " 51 ' - 3 " 51 ' - 3 " 51 ' - 3 " 200 ELECTRICAL ROOM 300 FIRE PUMP ROOM 100 WAREHOUSE 1 2 2 A 2 A 2 A 2 A 5'-2"4" 6'-2"6'-2" 5'-6"5'-6"5'-6" 9'-0"9'-0" A2.1.1 OVERALL FLOOR PLAN SHEET NUMBER DRAWN BY: ISSUE DATE: REVISIONS:# DY N A T E N - S H E L L I M P R O V E M E N T S THIS DESIGN AND THESE DRAWINGS ARE THE PROPERTY OF GMA ARCHITECT, INC. NO PART OF THIS WORK MAY BE REPRODUCED WITHOUT PRIOR WRITTEN PERMISSION FROM GMA ARCHITECTS, INC. AHT 02.24.2026 PR O J E C T : CIVIL HALFF ASSOCIATES, INC. 1201 NORTH BOWSER ROAD RICHARDSON, TX 75081 P: 214-346-6200 7930 CLAYTON ROAD, SUITE 300 RICHMOND HEIGHTS, MO 63117 P: (314) 822-5191 WWW.GMA-ARCHITECTS.COM 4849 GREENVILLE AVE. SUITE 1460 DALLAS, TX 75206 P: (214) 377-6681 WWW.ARCOMURRAY.COM 36 4 2 E U L E S S - G R A P E V I N E R O A D GR A P E V I N E , T X 7 6 0 5 1 06.25.2026 ARCO JOB NO:D249 GMA JOB NO:GA1997 STRUCTURAL RICHARD ADAMS ENGINEERS 5507 EAST BUSCH BLVD TEMPLE TERRACE, FLORIDA 33617 P: 813-985-4600 06.25.20 2 6 REV #1 |04.02.2026 REV #2 |06.25.2026 SCALE: 1/4" = 1'-0" A 1.DIMENSIONS SHOWN FOR EXTERIOR WINDOWS ARE TO ROUGH OPENING SIZES, UNLESS NOTED OTHERWISE. 2.PROVIDE 1/2" SHIM AROUND ENTIRE PERIMETER OF ROUGH OPENINGS. 3.FIELD VERIFY ROUGH OPENING SIZES PRIOR TO FABRICATION. 4.ALL ALUMINUM FRAMES TO INCLUDE SOLID PLASTIC BACKING/CAP WHERE FRAME ABUTS CONCRETE PANEL. WINDOW NOTES G-1 1" INSULATED GLASS (GRAYLITE II OR APPROVED EQUAL) IN PRE-FINISHED, CLEAR ANODIZED, THERMALLY BROKEN, ALUMINUM FRAME GLAZING LEGEND EXTERIOR WINDOW TYPES FINISH FLOOR 100' - 0" GLAZING IN PRE-FINISHED ALUMINUM FRAME 3' - 1 1 / 4 " AF F 2"2" 2'-6"2'-6" 5'-6" R.O. 2" 2" 2" 3' - 5 5 / 8 " 2" 5' - 2 " R . O . 1' - 2 3 / 8 " 1 A4.5.1 2 A4.5.1 1 A4.5.1 INTERIOR EXISTING TILT-UP CONCRETE WALL PANEL SCHEDULED INSULATED GLAZING IN THERMALLY BROKEN ALUMINUM STOREFRONT WINDOW SYSTEM -SEE WINDOW TYPES SEE STRUCTURAL 2" MIN 4 1/2" TILT WALL ALUMINUM WINDOW HEAD AND JAMB DETAIL SCALE: 3" = 1'-0"WH/417 - V3M 1/2" MIN TILT-UP CONCRETE WALL PANEL (BEYOND) 3/ 4 " 3/4" 1/2" 3/4" 3/4" V-GROOVE DRIP NOTCH (AT HEAD CONDITION ONLY) 3/4" CHAMFER (AT HEAD AND JAMB) EXTERIOR EXTERIOR GRADE SHIM WITH CONTINUOUS SEALANT BOTH SIDES TILT WALL ALUMINUM WINDOW SILL DETAIL SCALE: 3" = 1'-0"WH/418 - V2M EXISTING TILT-UP CONCRETE WALL PANEL SCHEDULED INSULATED GLAZING IN THERMALLY BROKEN ALUMINUM STOREFRONT WINDOW SYSTEM -SEE WINDOW TYPES ALUMINUM SUB-SILL FLASHING WITH END DAMS, SET IN DOUBLE BEAD OF SEALANT, TURN UP 1/2" PAST BACK OF WINDOW FRAME SEALANT WITH 1/2" GAP EVERY 12" OR WEEPS INSTALLED EXTERIOR GRADE SHIM AND FLASHING -SHIM FLASHING AS REQUIRED TO MAINTAIN POSITIVE DRAINAGE 2" MIN 4 1/2" SEE STRUCTURAL 1/2" MIN SLOPE 1° TILT-UP CONCRETE WALL PANEL (BEYOND) 3/4" CHAMFER SEALANT AT ENDS WITH MINIMUM 1/8" GAP AND NO SEALANT ON TOP INTERIOREXTERIOR A4.5.1 1 A4.5.1 2 A4.5.1 WINDOW SCHEDULE SHEET NUMBER DRAWN BY: ISSUE DATE: REVISIONS:# DY N A T E N - S H E L L I M P R O V E M E N T S THIS DESIGN AND THESE DRAWINGS ARE THE PROPERTY OF GMA ARCHITECT, INC. NO PART OF THIS WORK MAY BE REPRODUCED WITHOUT PRIOR WRITTEN PERMISSION FROM GMA ARCHITECTS, INC. AHT 02.24.2026 PR O J E C T : CIVIL HALFF ASSOCIATES, INC. 1201 NORTH BOWSER ROAD RICHARDSON, TX 75081 P: 214-346-6200 7930 CLAYTON ROAD, SUITE 300 RICHMOND HEIGHTS, MO 63117 P: (314) 822-5191 WWW.GMA-ARCHITECTS.COM 4849 GREENVILLE AVE. SUITE 1460 DALLAS, TX 75206 P: (214) 377-6681 WWW.ARCOMURRAY.COM 36 4 2 E U L E S S - G R A P E V I N E R O A D GR A P E V I N E , T X 7 6 0 5 1 04.02.2026 ARCO JOB NO:D249 GMA JOB NO:GA1997 STRUCTURAL RICHARD ADAMS ENGINEERS 5507 EAST BUSCH BLVD TEMPLE TERRACE, FLORIDA 33617 P: 813-985-4600 04.02.20 2 6 Agenda Item # III. B. CU26-22.4sprc 1 TO: SITE PLAN REVIEW COMMITTEE MEMBERS FROM: ALBERT L. TRIPLETT, JR. PLANNER II DATE: AUGUST 5, 2026 SUBJECT: CONDITIONAL USE REQUEST CU26-22; DYNATEN IMPROVEMENTS, 3642 EULESS-GRAPEVINE ROAD RECOMMENDATION Staff recommends the Site Plan Review Committee (SPRC) consider the proposed changes to amend the previously approved conditional use request CU23-02 (Ord. 2023- 028) for outdoor storage in conjunction with the development of an industrial warehouse building. This request is specifically to revise the eastern and western building elevations. The property is zoned “PID”, Planned Industrial Development District, and is platted as Block 1, Lot 4AG, Curnes Addition. REQUEST The applicant requests to amend the previously approved elevations of conditional use request CU23-02 (Ord. 2023-028). This request is specifically to install four (4) additional windows along the east elevation and two (2) roll-up dock doors along the west elevation. BACKGROUND INFORMATION The subject site and surrounding properties were zoned “R-1”, Single-Family Dwelling District prior to the 1984 City-wide Rezoning. Once a portion of the A.C. Stone tract, the property was a part of the City of Grapevine’s Extraterritorial Jurisdiction (ETJ). When the property was re-annexed in November of 1993, it received the zoning designation “R- 20”, Single-Family District, which is the default designation given to all property immediately after annexation. • On December 16, 2008, City Council approved SU08 -05 (Ord. 2008-76) on the subject site to allow for gas well drilling and production in a non-residential zoning district. • On February 16, 2010, City Council approved a one-year extension of SU08-05 on the subject site to allow gas well drilling and production in a non-residential zoning district to expire on December 16, 2010. • On May 16, 2023, City Council approved CU23-02 (Ord. 2023-028) to allow outdoor storage in conjunction with the development of an industrial warehouse building. Agenda item # III. B. CU26-22.4sprc 2 • On December 5, 2025, the Site Plan Review Committee approved CU25-46 to amend the previously approved plans CU23-02 (Ord. 2023-028) to allow for the installation of an eight (8) foot tall ornamental security fence, an increase to the amount of parking by 128 spaces, and modifications to the elevations, including the addition of three (3) large drive-in doors with ramps, and the installation of additional windows. /mh