HomeMy WebLinkAboutSFRA2018-0573 * ffll�f DATE OF ISSUANCE:FBB 212018 ,GRAPEVINE a,� r=EB 0 8 20111 _ T h:. I '1 a PERMIT#: BUILDING PERMIT APPLICATION (PLEASE PRINT LEGIBLY—COMPLETE EN, JOB ADDRESS: 1082 Lavon Dr SUITE # LOT: BLOCK: SUBDIVISION: BUILDING CONTRACTOR(company name): Perma Pier Foundation Repair of TX CURRENT MAILING ADDRESS: 2821 E Randol Mill Rd $17-372-8$8W�Anca-I^ws R CITY/STATE/ZIP: Arlington, TX 76011 PH:# Fax#— 214-637-0440 PROPERTY OWNER: Kathy KuitZ CURRENT MAILING ADDRESS: 1082 Lavon Dr CITY/STATE/ZIP: Grap vine.. TX 76051 PHONE NUMBER: 972-407-6214 PROJECT VALUE: $_ 21750 FIRE SPRINKLERED? YES NO X WHAT TRADES WILL BE NEEDED? ELECTRIC PLUMBING MECHANICAL DESCRIPTION OF WORK TO BE DONE: Foundation repair: Install 2 concrete _piers USE OF BUILDING OR STRUCTURE: Residential NAME OF BUSINESS: Total Square Footage under roof: Square Footage of alteration/addition: ❑ I hereby certify that plans have been reviewed and the building will be inspected by a certified energy code inspector in accordance with State Law. Plan review and inspection documentation shall be made available to the Building Department(required for new buildings, alterations and additions) ❑ I hereby certify that plans have been submitted to the Texas Department of Licensing and Regulation for Accessibility Review. Control Number: (Not required for 1&2 family dwellings) ❑ I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas Department of Health. (REQUIRED FOR DEMOLITIONS,ADDITIONS AND OR ALTERATION TO COMMERCIAL AND PUBLIC BUILDINGS) I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. It is understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY,AND THAT THE DESIGN PROFESSIONAL/OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR FEDERAL AGENCY(S). PRINT NAME: Wanda Lawson SIGNATURE U aW'0& aZ41ee PHONE#: 817-372-8818 EMAIL: ❑ CHECK BOX IF PREFERRED TO BE CONTACTED BY E-MAIL THE FOLLOWING IS TO BE COMPLETED BY THE BUILDING INSPECTION DEPARTMENT Construction Type: - Permit Valuation: $ Setbacks Approval to Issue Occu ancy Grou : •3 Fire Sprinkler: YES NO Front: Electrical Division: Building Depth: Q Left: Plumbing Zoning: • Z Building Width: Rear: Mechanical Occupancy Load: OVA. vi Right: Plan Review Lk roval- ,r/ 1 Date:e-Z,®, Building Permit Fee: Site Plan Approval: Date: Plan Review Fee: Fire Department: Date: Lot Drainage Fee: Public Works Department: Date: Sewer Availability Rate: Health Department: Date: Water Availability Rate: Approved for Permit: ,d P,,-X5,,AJ Date: Z�Zo./$ Total Fees: Lot Drainage Submitted: Approved: Total Amount Due: P.O.BOX 95104,GRAPEVINE,TX 70099(817)410.3165 O:FORMSIOSPERMITAPPUCATIONS 1/02-Rw.11104,5106,2107,11199,4/11 � BUILDING --- RESIDENTIAL ALTERATION MWpr "5 J Issue Date:February 21,2018 PROJECT DESCRIPTION:Foundation Repair-Install(2)Concrete Piers nmmr j PROJECT# (817)410-3010 WWW.mygov.us SFRA-18-0573 Inspections Permits City of Grapevine - - LOCATION LEGAL P.O.Box 1082 Lavon Dr. Lake Pointe Blk 1 Lot 16a TX Grapevine,,TX 76099 Grapevine,TX 76051 (817)410-3165 Voice (817)410-3012 Fax CONTRACTOR INFORMATION Perma Pier Foundation Repair of Texas *CONSTRUCTION TYPE V-B 2821 East Randol Mill Road *OCCUPANCY GROUP R-3 Arlington,TX 76011 *ZONING DISTRICT R-7.5 (214)637-1444 Phone **APPLICANT NAME Wanda Lawson (214)637-0440 Fax (817)372-8818 Mobile **APPLICANT PHONE NUMBER 817-372-8818 wanda.lawson @permapier.com APPROVED TO ISSUE ELECTRIC NO APPROVED TO ISSUE MECHANICAL NO OWNER APPROVED TO ISSUE PLUMBING NO Jeremiah M Radandt — County Tarrant 1082 Lavon Dr Grapevine,TX 76051 Fire Sprinkler System? N/A Square Footage AVAILABLE INSPECTIONS VALUATION 2750 ► Building Final(required) FEES TOTAL=$74.75 Building Permit Fee $74.75 PAYMENTS TOTAL=$74.75 Perma Pier Foundation Repair of Texas(Eric Lawson) Other on 0212112018 ($74.75) Note:CCO420 NOTICES 1)ALL work must be done in compliance with the 2006 INTERNATIONAL BUILDING CODE. 2)A copy of the signed permit and approved plans must be on site at all times. 3)The project address must be clearly posted at the job site. READ AND SIGN I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by the Building Department and in compliance with the City of Grapevine Ordinance regulating construction. It is understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City of Grapevine.I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY,AND THAT THE DESIGN PROFESSIONAL/OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR MYGOV.US City of Grapevine I BUILDING--RESIDENTIAL ALTERATION I SFRA-18-0573 I Printed 02/21/18 at 2:12 p.m. Page 1 of 3 FEDF�RA 7Y(r", r � � Signature Date MYGOV.US City of Grapevine i BUILDING--RESIDENTIAL ALTERATION I SFRA-18-0573 i Printed 02/21118 at 2:12 p.m. Page 2 of 3 Farther Eir qhieefihg CoiisidtatitS, hie. Texas Registered Engineering Firm F-1499 /57n For Lane,Burleson. Testis 76028 M/7)447-84io February 1, 2018 ALL CHANGES REQUIRE Perna Pier Foundation Repair Company APPROVAL 2821 E. Randol kfill Road OF REVISED PLANS Arlington. Texas 76011 Re: Foundation Repair Plan— Permit Review Letter APPROVED PLANS SHALL BE KEPT ON JOBSITE ATALL TIMES The residence at 1082 Lavon Drive. Grapevine, Texas Perna Pier Job #r 2 179301 3 As requested by Perma Pier Foundation Repair Company. I have reviewed the repair proposal dated January 31, '_'018 provided for the above referenced property. The data indicates the structure has experienced movements that exceed generally accepted guidelines and therefore requires mechanical repairs as shown in the attached drawing. The plan ofrepair slioxvs at least 2 concrete pressed pilings should be installed at the locations indicated. Based on the information provided by Perma Pier, this repair plan appears to meet or exceed the minimum requirements of the 2015 international Residential Code. If the strength of the foundation system is found to be insufficient to support the spacing of the pilings shown on the attached sketch, then additional pilings may be required to adequately support the structure. The structure should be lifted and stabilized in as near original position as possible. Complete leveling ofthis structure should not be anticipated. CONTRACTOR SHALL CALL FOR After the house has been stabilized,the yard should be carefully regraded to cns ii9MT[Ql agc away from the house at all points. (817) 410-3010 If you have any questions concerning these Findings,please do not he SWNTRAtTOR REGISTRATION WILL BE REVOKED UPON Very truly yours, PERMIT EXPIRATION. S. 11. Prather, P.E. CITY OF GRAPEVINE RELEASE_ D FOR CONSTRUCTION OFFICE COPY SHEET: OF: 3 RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING OFMINANCE CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES DATE• So ! BY. BUILDING INSPECTION D O RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY. ALL CHANGES MUST BE APPROVED DEB Q 8 Z01I1 Prather Enqineei-h!g Consultants, late 1 711 k'av Lane,Burleson. Texas 760.M (817)447-5450 PERMA-PIER Foundation Repair of Texas 1082 Lavon Drive, Grapevine,Texas Perma Pier Job ft 2 1793013 V. e 0 nh lu tu L L GL NO NOTES UNLESS OTHERWISE SPECIFIED Prather Engineering Consultants,. Inc. 1570 Fox Lane Burlcsr)n,Texas 76028 (8171)447-8450 Prather En(lineering Consultants, hic 15,70 Fax Lane.lhurleson, Texas 76028 (817)447-8450 TA It i i - II 4 I`� a Prather Engineering Consultants, Inc. Texas Registered Enyineeriny Firm F-1499 1570 Fox Lane,Burleson, Texas 76028 (817)447-8450 February 20, 2018 Perma Pier Foundation Repair Company 2821 E. Randol Mill Road Arlington, Texas 76011 Perma Pier Job#21793013 RE: 1082 Lavon Drive, Grapevine, Texas As requested by Perma Pier Foundation Repair, I have reviewed the repair proposal and the installation data received from Perma Pier Foundation Repair regarding the corrections made to the above referenced property. Perma Pier Foundation Repair corrected the repaired portion of the foundation using 2 concrete- pressed pilings at the above referenced location for our review. Based on the field data provided to us by Perma Pier Foundation Repair,the piling locations and spacings represented are found to be in general compliance with the 2015 International Residential Code, and generally in agreement with Perma Pier Foundation Repair's proposal. In our opinion,the piling depths and the pile driving forces as recorded by Perma Pier Foundation Repair are generally appropriate for this type of structure located in the area where the work was performed. The repair work performed at the subject location is believed to have been acceptably completed based on the information provided by Perma Pier Foundation Repair, and in accordance with good industry practice for the specified foundation repair work. The repairs performed on this location are expected to minimize the foundation settlement observed prior to the repair work. It should, however,be noted that partial repairs modify the basic design of the foundation and differential movements may occur. Partial repairs are a generally accepted industry practice, but the possibility of future movement must be recognized. Non- supported areas are not covered against foundation movements by the contractor's warranty or the repair plan: In my opinion, the future performance of the foundation system at this location should function generally as intended,provided the proper soil moisture is maintained and there is not a loss in the load bearing capacity of the soil. Soils near the structure should be graded such that there is positive drainage away from the foundation. A drainage system can be installed to prevent water from ponding around the foundation if necessary. A foundation maintenance program is recommended, which can be found at www.foundationl)erformance.or . If you have any questions concerning these findings,please do not hesitate to call. Very truly yours, S. H. Prather, P.E. F r", ' .� y � x4055 O. s�lST4..... '? NAI