Loading...
HomeMy WebLinkAboutCOMM2016-2464 Testing of the Medium voltage cables At the Gaylord Texan For CEC DALLAS OFFICE Thomas Coon - Operations Manager Curtis Clover - Sales Manager 783 N. Grove Rd Suite 101 Richardson, TX 75081 Office: 972.907.3783 t.coon@epsii.com c.clover@epsii.com PROJECT DETAILS PROJECT SUMMARY 1.0 SUMMARY 2.0 EQUIPMENT TESTED AND INSPECTED 3.0 INSPECTION AND TEST PROCEDURES 4.0 RESULTS 5.0 TEST RESULTS Table of Contents CLIENT CEC PROJECT Gaylord Texan PROJECT ADDRESS 890 Redbud Lane, Grapevine, Texas START DATE August 7, 2017 END DATE August 10, 2017 EPS PROJECT LEAD Justin Parks EPS FIELD ENGINEERS Justin Parks and Josh Arenas JOB REFERENCE DAL17-147 REPORT PREPARED BY Justin Parks REPORT APPROVED BY Justin Parks Project Details 1.0 SUMMARY This project was initiated to perform medium voltage terminations and testing. All items were tested according to NETA ATS-17 and job specifications. All work was performed onsite by Justin Parks and Josh arenas of Electric Power Systems. 2.0 EQUIPMENT TESTED AND INSPECTED 2.1 (24) Twenty-Four Medium voltage terminations 2.2 (4)Four Sets of Medium voltage cable High-pot tested 3.0 INSPECTION AND TEST PROCEDURES 3.1 4.0 RESULTS 4.1 Tested per Electric Power Systems test procedures within NETA ATS 2017 guidelines and job specifications. Unless otherwise specified, all equipment tested was within Manufacturer tolerances as well as NETA specifications (NETA ATS-17). Project Summary . DA L L A S D I V I S O N (9 7 2 ) 9 0 7 - 3 7 8 3 TE S T E Q U I P M E N T U S E D : M E G G E R : T U L 0 0 1 3 C A L D A T E : 2 - 1 0 - 1 6 / 1 7 HIP O T : T U L 0 0 0 9 C A L D A T E : 2 - 1 1 - 1 6 / 1 7 IN S U L A T I O N T Y P E : E P R 1 3 3 % KV T I M E T I M E VO L T A G E : 2 5 K V G N D : X U N G N D : 5 s t e p s P h a s e A P h a s e B P h a s e C ( M I N ) P h a s e A P h a s e B P h a s e C ( S E C ) P h a s e A P h a s e B P h a s e C CO N D U C T O R S I Z E : 1 / 0 C O P P E R : X A L U M : 1 6 0 . 1 8 0 . 1 2 0 . 1 2 3 0 s e c 1 . 8 0 . 5 0 . 4 8 1 0 s e c 1 1 1 LE N G T H : 2 5 F T S H L D : X U N S H L D 3 2 0 . 2 6 0 . 2 0 . 2 1 m i n 1 . 8 0 . 4 8 0 . 4 8 1 5 s e c 0 0 0 DA T E I N S T A L L E D : 8 / 1 7 4 8 0 . 3 8 0 . 2 8 0 . 2 8 2 m i n 1 . 6 0 . 4 8 0 . 4 6 2 0 s e c 0 0 0 64 0 . 9 2 0 . 3 8 0 . 3 8 3 m i n 1 . 5 0 . 4 8 0 . 4 6 3 0 s e c 0 0 0 78 1 . 8 0 . 5 0 . 4 8 4 m i n 1 . 4 0 . 4 8 0 . 4 2 4 0 s e c 0 0 0 TE S T V O L T A G E 7 8 K v 5 m i n 1 . 1 0 . 4 8 0 . 4 2 5 0 s e c 0 0 0 T E M P 8 4 ° F 6 m i n 1 0 . 4 8 0 . 4 2 7 m i n 0 . 9 0 . 4 6 0 . 4 2 A- G N D 8 m i n 0 . 8 8 0 . 4 6 0 . 4 2 B- G N D 9 m i n 0 . 8 4 0 . 4 6 0 . 4 2 C- G N D 10 m i n 0 . 8 0 . 4 4 0 . 4 2 11 m i n 0 . 8 0 . 4 4 0 . 4 2 A 12 m i n 0 . 6 0 . 4 4 0 . 4 2 B 13 m i n 0 . 5 5 0 . 4 4 0 . 4 2 C 14 m i n 0 . 5 5 0 . 4 4 0 . 4 15 m i n 0 . 5 5 0 . 4 4 0 . 4 P. M . U . T O S E S - C El e c t r i c P o w e r S y s t e m s El e c t r i c a l T e s t i n g a n d E n g i n e e r i n g . . . Full Member D. C . H I G H P O T E N T I A L T E S T R E P O R T CU S T O M E R : JO B N O : D A L 1 7 - 0 0 0 LO C A T I O N : DA T E : 0 8 / 0 8 / 1 7 TE S T E D B Y : J T A CA B L E I D E N T I F I C A T I O N : CE C E L E C T R I C G A Y L O R D T E X A N S R E S O R T GR A P E V I N E , T X CA B L E I N F O R M A T I O N EL E C T R I C A L T E S T D A T A ST E P V O L T A G E T E S T L E A K A G E A T T E S T V O L T A G E CA B L E M F G : G E N E R A L C A B L E HU M I D I T Y 6 1 % MI L S : 3 4 5 M E G G E R T E S T A T 2 5 0 0 V O L T S D C ( I N M E G O H M S ) >1 0 , 0 0 0 >1 0 , 0 0 0 NO . T E R M : 6 0 . 3 Ω >1 0 , 0 0 0 SH I E L D C O N T I N U I T Y 0 . 3 Ω 0 . 2 Ω ST A B I L I Z A T I O N T I M E 1 M I N . RE M A R K S : VOLTAGE DECAY MI C R O A M P S M I C R O A M P S K I L O V O L T S TE S T I N F O R M A T I O N NO . S T E P S : 5 16 3 2 4 8 6 4 7 8 Ph a s e A 0. 1 8 0 . 2 6 0 . 3 8 0 . 9 2 1 . 8 Ph a s e B 0. 1 2 0 . 2 0 . 2 8 0 . 3 8 0 . 5 Ph a s e C 0. 1 2 0 . 2 0 . 2 8 0 . 3 8 0 . 4 8 0 0. 2 0. 4 0. 6 0. 8 1 1. 2 1. 4 1. 6 1. 8 2 Leakage Current (uA) Vo l t a g e ( K V ) St e p V o l t a g e T e s t f o r F e e d e r " P. M . U . T O S E S - C " Phase A Phase B Phase C 30  se c 1  mi n 2  mi n 3  mi n 4  mi n 5  mi n 6  mi n 7  mi n 8  mi n 9  mi n 10 mi n 11 mi n 12 mi n 13 mi n 14 mi n 15 min Ph a s e  A 1. 8 1 . 8 1 . 6 1 . 5 1 . 4 1 . 1 1 0 . 9 0 . 8 8 0 . 8 4 0 . 8 0 . 8 0 . 6 0 . 5 5 0 . 5 5 0 . 5 5 Ph a s e  B 0. 5 0 . 4 8 0 . 4 8 0 . 4 8 0 . 4 8 0 . 4 8 0 . 4 8 0 . 4 6 0 . 4 6 0 . 4 6 0 . 4 4 0 . 4 4 0 . 4 4 0 . 4 4 0 . 4 4 0 . 4 4 Ph a s e  C 0. 4 8 0 . 4 8 0 . 4 6 0 . 4 6 0 . 4 2 0 . 4 2 0 . 4 2 0 . 4 2 0 . 4 2 0 . 4 2 0 . 4 2 0 . 4 2 0 . 4 2 0 . 4 2 0 . 4 0 . 4 0 0. 2 0. 4 0. 6 0. 8 1 1. 2 1. 4 1. 6 1. 8 2 Leakage Current @ 78 KV (UA) Ti m e  (m i n u t e s ) Ab s o r p t i o n  Te s t  fo r  Fe e d e r  "P . M . U .  TO  SE S ‐C  " Phase A Phase B Phase C 10 s e c 1 5 s e c 2 0 s e c 3 0 s e c 4 0 s e c 5 0 s e c Ph a s e A 10 0 0 0 0 Ph a s e B 10 0 0 0 0 Ph a s e C 10 0 0 0 0 0 0. 2 0. 4 0. 6 0. 8 1 1. 2 Decay Voltage (KV) Vo l t a g e D e c a y " P. M . U . T O S E S - C " Phase A Phase B Phase C . DA L L A S D I V I S O N (9 7 2 ) 9 0 7 - 3 7 8 3 TE S T E Q U I P M E N T U S E D : M E G G E R : T U L 0 0 1 3 C A L D A T E : 2 - 1 0 - 1 6 / 1 7 HIP O T : T U L 0 0 0 9 C A L D A T E : 2 - 1 1 - 1 6 / 1 7 IN S U L A T I O N T Y P E : E P R 1 3 3 % KV T I M E T I M E VO L T A G E : 2 5 K V G N D : X U N G N D : 5 s t e p s P h a s e A P h a s e B P h a s e C ( M I N ) P h a s e A P h a s e B P h a s e C ( S E C ) P h a s e A P h a s e B P h a s e C CO N D U C T O R S I Z E : 1 / 0 C O P P E R : X A L U M : 1 6 0 . 3 2 0 . 1 8 0 . 8 6 3 0 s e c 2 4 3 2 3 8 1 0 s e c 2 0 2 0 1 9 LE N G T H : 9 9 0 F T S H L D : X U N S H L D 3 2 1 . 2 1 2 . 2 1 m i n 2 4 3 2 3 8 1 5 s e c 9 1 0 1 2 DA T E I N S T A L L E D : 8 / 1 7 4 8 4 . 2 2 . 6 4 2 m i n 2 4 3 0 3 4 2 0 s e c 5 6 8 64 1 2 8 1 6 3 m i n 2 4 3 0 3 4 3 0 s e c 3 4 6 78 2 4 3 2 3 8 4 m i n 2 4 3 0 3 4 4 0 s e c 1 1 3 TE S T V O L T A G E 7 8 K v 5 m i n 2 2 2 8 3 4 5 0 s e c 0 0 1 T E M P 8 4 ° F 6 m i n 2 2 2 8 3 2 6 0 s e c 0 0 0 7 m i n 2 2 2 6 3 0 A- G N D 8 m i n 2 2 2 6 3 0 B- G N D 9 m i n 2 0 2 4 3 0 C- G N D 10 m i n 2 0 2 2 3 0 11 m i n 2 0 2 2 3 0 A 12 m i n 1 8 1 8 2 8 B 13 m i n 1 8 1 8 2 6 C 14 m i n 1 6 1 8 2 6 15 m i n 1 6 1 8 2 4 RE M A R K S : VOLTAGE DECAY MI C R O A M P S M I C R O A M P S K I L O V O L T S TE S T I N F O R M A T I O N NO . S T E P S : 5 >1 0 , 0 0 0 SH I E L D C O N T I N U I T Y 0 . 4 Ω 0 . 5 Ω ST A B I L I Z A T I O N T I M E 1 M I N . M E G G E R T E S T A T 2 5 0 0 V O L T S D C ( I N M E G O H M S ) >1 0 , 0 0 0 >1 0 , 0 0 0 NO . T E R M : 6 0 . 5 Ω CA B L E I N F O R M A T I O N EL E C T R I C A L T E S T D A T A ST E P V O L T A G E T E S T L E A K A G E A T T E S T V O L T A G E CA B L E M F G : G E N E R A L C A B L E HU M I D I T Y 6 1 % MI L S : 3 4 5 TE S T E D B Y : J T A CA B L E I D E N T I F I C A T I O N : CE C E L E C T R I C G A Y L O R D T E X A N S R E S O R T GR A P E V I N E , T X SE S - C t o P M S - C El e c t r i c P o w e r S y s t e m s El e c t r i c a l T e s t i n g a n d E n g i n e e r i n g . . . Full Member D. C . H I G H P O T E N T I A L T E S T R E P O R T CU S T O M E R : JO B N O : D A L 1 7 - 0 0 0 LO C A T I O N : DA T E : 0 8 / 0 8 / 1 7 16 3 2 4 8 6 4 7 8 Ph a s e A 0. 3 2 1 . 2 4 . 2 1 2 2 4 Ph a s e B 0. 1 8 1 2 . 6 8 3 2 Ph a s e C 0. 8 6 2 . 2 4 1 6 3 8 0510152025303540 Leakage Current (uA) Vo l t a g e ( K V ) St e p V o l t a g e T e s t f o r F e e d e r " S E S - C t o P M S - C " Phase A Phase B Phase C 30  se c 1  mi n 2  mi n 3  mi n 4  mi n 5  mi n 6  mi n 7  mi n 8  mi n 9  mi n 10 mi n 11 mi n 12 mi n 13 mi n 14 mi n 15 min Ph a s e  A 24 2 4 2 4 2 4 2 4 2 2 2 2 2 2 2 2 2 0 2 0 2 0 1 8 1 8 1 6 1 6 Ph a s e  B 32 3 2 3 0 3 0 3 0 2 8 2 8 2 6 2 6 2 4 2 2 2 2 1 8 1 8 1 8 1 8 Ph a s e  C 38 3 8 3 4 3 4 3 4 3 4 3 2 3 0 3 0 3 0 3 0 3 0 2 8 2 6 2 6 2 4 0510152025303540 Leakage Current @ 78 KV (UA) Ti m e  (m i n u t e s ) Ab s o r p t i o n  Te s t  fo r  Fe e d e r  "S E S ‐C to  PM S ‐C" Phase A Phase B Phase C 10 s e c 1 5 s e c 2 0 s e c 3 0 se c 4 0 s e c 5 0 s e c 6 0 s e c Ph a s e A 20 9 5 3 1 0 0 Ph a s e B 201 0 6 4 1 0 0 Ph a s e C 191 2 8 6 3 1 0 0510152025 Decay Voltage (KV) Vo l t a g e D e c a y " S E S - C t o P M S - C " Phase A Phase B Phase C . DA L L A S D I V I S O N (9 7 2 ) 9 0 7 - 3 7 8 3 TE S T E Q U I P M E N T U S E D : M E G G E R : T U L 0 0 1 3 C A L D A T E : 2 - 1 0 - 1 6 / 1 7 HIP O T : T U L 0 0 0 9 C A L D A T E : 2 - 1 1 - 1 6 / 1 7 IN S U L A T I O N T Y P E : E P R 1 3 3 % KV T I M E T I M E VO L T A G E : 2 5 K V G N D : X U N G N D : 5 s t e p s P h a s e A P h a s e B P h a s e C ( M I N ) P h a s e A P h a s e B P h a s e C ( S E C ) P h a s e A P h a s e B P h a s e C CO N D U C T O R S I Z E : 1 / 0 C O P P E R : X A L U M : 1 6 0 . 3 0 . 2 6 0 . 3 3 3 0 s e c 1 6 1 4 1 7 1 0 s e c 3 3 4 LE N G T H : 2 0 0 F T S H L D : X U N S H L D 3 2 0 . 7 0 . 8 0 . 9 1 m i n 1 6 1 4 1 7 1 5 s e c 1 1 1 DA T E I N S T A L L E D : 8 / 1 7 4 8 1 . 1 1 . 6 1 . 4 2 m i n 1 6 1 4 1 7 2 0 s e c 0 0 0 64 5 . 4 4 . 8 5 . 1 3 m i n 1 6 1 4 1 7 3 0 s e c 0 0 0 78 1 6 1 4 1 7 4 m i n 1 5 1 3 1 6 4 0 s e c 0 0 0 TE S T V O L T A G E 7 8 K v 5 m i n 1 5 1 3 1 6 5 0 s e c 0 0 0 T E M P 8 4 ° F 6 m i n 1 5 1 3 1 6 6 0 s e c 0 0 0 7 m i n 1 5 1 3 1 6 A- G N D 8 m i n 1 4 1 3 1 4 B- G N D 9 m i n 1 4 1 3 1 4 C- G N D 10 m i n 1 4 1 3 1 4 11 m i n 1 4 1 3 1 4 A 12 m i n 1 4 1 3 1 4 B 13 m i n 1 4 1 3 1 4 C 14 m i n 1 3 1 2 1 3 15 m i n 1 3 1 2 1 2 PM S - C t o M V C - A El e c t r i c P o w e r S y s t e m s El e c t r i c a l T e s t i n g a n d E n g i n e e r i n g . . . Full Member D. C . H I G H P O T E N T I A L T E S T R E P O R T CU S T O M E R : JO B N O : D A L 1 7 - 0 0 0 LO C A T I O N : DA T E : 8 / 9 / 1 7 TE S T E D B Y : J P CA B L E I D E N T I F I C A T I O N : CE C E L E C T R I C G A Y L O R D T E X A N S R E S O R T GR A P E V I N E , T X CA B L E I N F O R M A T I O N EL E C T R I C A L T E S T D A T A ST E P V O L T A G E T E S T L E A K A G E A T T E S T V O L T A G E CA B L E M F G : G E N E R A L C A B L E HU M I D I T Y 6 1 % MI L S : 3 4 5 M E G G E R T E S T A T 2 5 0 0 V O L T S D C ( I N M E G O H M S ) >1 0 , 0 0 0 >1 0 , 0 0 0 NO . T E R M : 6 0 . 3 Ω >1 0 , 0 0 0 SH I E L D C O N T I N U I T Y 0 . 4 Ω 0 . 5 Ω ST A B I L I Z A T I O N T I M E 1 M I N . RE M A R K S : T e r m s a r e L o a d b r e a k t o S t r e s s C o n e VOLTAGE DECAY MI C R O A M P S M I C R O A M P S K I L O V O L T S TE S T I N F O R M A T I O N NO . S T E P S : 5 16 3 2 4 8 6 4 7 8 Ph a s e A 0. 3 0 . 7 1 . 1 5 . 4 1 6 Ph a s e B 0. 2 6 0 . 8 1 . 6 4 . 8 1 4 Ph a s e C 0. 3 3 0 . 9 1 . 4 5 . 1 1 7 024681012141618 Leakage Current (uA) Vo l t a g e ( K V ) St e p V o l t a g e T e s t f o r F e e d e r " PM S - C t o M V C - A " Phase A Phase B Phase C 30  se c 1  mi n 2  mi n 3  mi n 4  mi n 5  mi n 6  mi n 7  mi n 8  mi n 9  mi n 10 mi n 11 mi n 12 mi n 13 mi n 14 mi n 15 min Ph a s e  A 16 1 6 1 6 1 6 1 5 1 5 1 5 1 5 1 4 1 4 1 4 1 4 1 4 1 4 1 3 1 3 Ph a s e  B 14 1 4 1 4 1 4 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 2 1 2 Ph a s e  C 17 1 7 1 7 1 7 1 6 1 6 1 6 1 6 1 4 1 4 1 4 1 4 1 4 1 4 1 3 1 2 024681012141618 Leakage Current @ 78 KV (UA) Ti m e  (m i n u t e s ) Ab s o r p t i o n  Te s t  fo r  Fe e d e r  "PM S ‐C to  MV C ‐A" Phase A Phase B Phase C 10 s e c 1 5 s e c 2 0 s e c 3 0 se c 4 0 s e c 5 0 s e c 6 0 s e c Ph a s e A 31 0 0 0 0 0 Ph a s e B 31 0 0 0 0 0 Ph a s e C 41 0 0 0 0 0 0 0. 5 1 1. 5 2 2. 5 3 3. 5 4 4. 5 Decay Voltage (KV) Vo l t a g e D e c a y " PM S - C t o M V C - A " Phase A Phase B Phase C . DA L L A S D I V I S O N (9 7 2 ) 9 0 7 - 3 7 8 3 TE S T E Q U I P M E N T U S E D : M E G G E R : T U L 0 0 1 3 C A L D A T E : 2 - 1 0 - 1 6 / 1 7 HIP O T : T U L 0 0 0 9 C A L D A T E : 2 - 1 1 - 1 6 / 1 7 IN S U L A T I O N T Y P E : E P R 1 3 3 % KV T I M E T I M E VO L T A G E : 2 5 K V G N D : X U N G N D : 5 s t e p s P h a s e A P h a s e B P h a s e C ( M I N ) P h a s e A P h a s e B P h a s e C ( S E C ) P h a s e A P h a s e B P h a s e C CO N D U C T O R S I Z E : 1 / 0 C O P P E R : X A L U M : 1 6 0 . 4 4 0 . 2 4 0 . 6 4 3 0 s e c 1 8 9 . 8 1 2 1 0 s e c 3 3 4 LE N G T H : 2 7 0 F T S H L D : X U N S H L D 3 2 0 . 9 0 . 4 8 1 . 6 1 m i n 1 8 9 . 8 1 0 1 5 s e c 1 1 1 DA T E I N S T A L L E D : 8 / 1 7 4 8 1 . 5 0 . 8 2 . 8 2 m i n 1 8 9 . 8 1 0 2 0 s e c 0 0 0 64 9 . 8 3 . 2 5 . 4 3 m i n 1 8 9 . 4 1 0 3 0 s e c 0 0 0 78 1 8 9 . 8 1 2 4 m i n 1 8 9 . 4 1 0 4 0 s e c 0 0 0 TE S T V O L T A G E 7 8 K v 5 m i n 1 6 9 . 4 1 0 5 0 s e c 0 0 0 T E M P 8 4 ° F 6 m i n 1 6 9 9 . 8 6 0 s e c 0 0 0 7 m i n 1 6 9 9 . 4 A- G N D 8 m i n 1 6 9 9 . 4 B- G N D 9 m i n 1 6 9 9 . 4 C- G N D 10 m i n 1 5 9 9 . 2 11 m i n 1 5 9 9 . 2 A 12 m i n 1 5 8 . 8 8 . 6 B 13 m i n 1 4 8 . 4 8 . 4 C 14 m i n 1 4 8 . 4 8 . 4 15 m i n 1 4 8 . 4 8 . 4 PM S - C t o M V C - B El e c t r i c P o w e r S y s t e m s El e c t r i c a l T e s t i n g a n d E n g i n e e r i n g . . . Full Member D. C . H I G H P O T E N T I A L T E S T R E P O R T CU S T O M E R : JO B N O : D A L 1 7 - 0 0 0 LO C A T I O N : DA T E : 0 8 / 0 8 / 1 7 TE S T E D B Y : J T A CA B L E I D E N T I F I C A T I O N : CE C E L E C T R I C G A Y L O R D T E X A N S R E S O R T GR A P E V I N E , T X CA B L E I N F O R M A T I O N EL E C T R I C A L T E S T D A T A ST E P V O L T A G E T E S T L E A K A G E A T T E S T V O L T A G E CA B L E M F G : G E N E R A L C A B L E HU M I D I T Y 6 1 % MI L S : 3 4 5 M E G G E R T E S T A T 2 5 0 0 V O L T S D C ( I N M E G O H M S ) >1 0 , 0 0 0 >1 0 , 0 0 0 NO . T E R M : 6 0 . 3 Ω >1 0 , 0 0 0 SH I E L D C O N T I N U I T Y 0 . 2 Ω 0 . 2 Ω ST A B I L I Z A T I O N T I M E 1 M I N . RE M A R K S : VOLTAGE DECAY MI C R O A M P S M I C R O A M P S K I L O V O L T S TE S T I N F O R M A T I O N NO . S T E P S : 5 16 3 2 4 8 6 4 7 8 Ph a s e A 0. 4 4 0 . 9 1 . 5 9 . 8 1 8 Ph a s e B 0. 2 4 0 . 4 8 0 . 8 3 . 2 9 . 8 Ph a s e C 0. 6 4 1 . 6 2 . 8 5 . 4 1 2 02468101214161820 Leakage Current (uA) Vo l t a g e ( K V ) St e p V o l t a g e T e s t f o r F e e d e r " P M S - C t o M V C - B " Phase A Phase B Phase C 30  se c 1  mi n 2  mi n 3  mi n 4  mi n 5  mi n 6  mi n 7  mi n 8  mi n 9  mi n 10 mi n 11 mi n 12 mi n 13 mi n 14 mi n 15 min Ph a s e  A 18 1 8 1 8 1 8 1 8 1 6 1 6 1 6 1 6 1 6 1 5 1 5 1 5 1 4 1 4 1 4 Ph a s e  B 9. 8 9 . 8 9 . 8 9 . 4 9 . 4 9 . 4 9 9 9 9 9 9 8 . 8 8 . 4 8 . 4 8 . 4 Ph a s e  C 12 1 0 1 0 1 0 1 0 1 0 9 . 8 9 . 4 9 . 4 9 . 4 9 . 2 9 . 2 8 . 6 8 . 4 8 . 4 8 . 4 02468101214161820 Leakage Current @ 78 KV (UA) Ti m e  (m i n u t e s ) Ab s o r p t i o n  Te s t  fo r  Fe e d e r  "P M S ‐C to  MV C ‐B" Phase A Phase B Phase C 10 s e c 1 5 s e c 2 0 s e c 3 0 se c 4 0 s e c 5 0 s e c 6 0 s e c Ph a s e A 31 0 0 0 0 0 Ph a s e B 31 0 0 0 0 0 Ph a s e C 41 0 0 0 0 0 0 0. 5 1 1. 5 2 2. 5 3 3. 5 4 4. 5 Decay Voltage (KV) Vo l t a g e D e c a y " P M S - C t o M V C - B " Phase A Phase B Phase C PM S - C SE S - C Grapevine, Texas 76051 WO-04790545 Service Report August 20, 2017 GAYLORD TEXAN David Nicklas WO-04790545 890 Redbud Lane Project #: Subject: Customer PO.: Scope of Work Summary Report Organization Grapevine WO-04790545 Table of Contents Job #WO-04790545 PAGE NO. Site Location Customer GAYLORD TEXANEnd User DeviceDesignation Substation Cover Letter 14201 - SE REPORT COVER SHEET Main Grapevine, TX 76051 7B Feeder 18 03001 - SE LOW VOLT. PWR. CKT. BKR. Main Grapevine, TX 76051 7B Feeder 19 03001 - SE LOW VOLT. PWR. CKT. BKR. Main Grapevine, TX 76051 A2 03001 - SE LOW VOLT. PWR. CKT. BKR. Main Grapevine, TX 76051 A2 Groundfault 08001 - SE LV Ground Fault System Main Grapevine, TX 76051 A3 03001 - SE LOW VOLT. PWR. CKT. BKR. Main Grapevine, TX 76051 A3 Groundfault 08001 - SE LV Ground Fault System Main Grapevine, TX 76051 A4 Feeder 03001 - SE LOW VOLT. PWR. CKT. BKR. Main Grapevine, TX 76051 B6 03001 - SE LOW VOLT. PWR. CKT. BKR. Main Grapevine, TX 76051 B6 Groundfault 08001 - SE LV Ground Fault System Main Grapevine, TX 76051 B8 03001 - SE LOW VOLT. PWR. CKT. BKR. Main Grapevine, TX 76051 B9 03001 - SE LOW VOLT. PWR. CKT. BKR. Main Grapevine, TX 76051 B9 Groundfault 08001 - SE LV Ground Fault System Main Grapevine, TX 76051 MCV-A Transformer 23210 - SE DRY TYPE TRANSFORMER Main Grapevine, TX 76051 MVC-A 06070 - SE MV HVLcc / Visi-Vac Main Grapevine, TX 76051 MVC-B 06070 - SE MV HVLcc / Visi-Vac Main Grapevine, TX 76051 MVC-B Transformer 23210 - SE DRY TYPE TRANSFORMER ZONE INTLK BREAKER TYPE TRIP UNIT TYPE 0202306805530001 BKR INT. RATING MOUNTING HUMIDITY WO-04790545 LOW VOLTAGE POWER CIRCUIT BREAKER TEMPERATURE 85 °F PAGE END USER CUSTOMER Grapevine, TX 76051 GAYLORD TEXAN SITE LOCATION 7B Feeder 18DESIGNATION SUBSTATION Main DATE END USER ASSET/ID 8/22/2017 71 JOB # % DBID 7B Feeder 18 08-547640 DEVICE 03001 - SE LOW VOLT. PWR. CKT. BKR. TESTED BY EQUIPMENT USEDJames Jillson Sevondary Injection, Megger, Ductor 800 N/A N/A N/A MATCHES DWG OR SPEC GROUND CONNECTION ONPowerpact PJ 100 ka MANUFACTURER FUSE MFR. BKR CATALOG NO.PJA36080U43A N/AFUSE CAT. NO. 800 OFF B.I. THERMAL MEMORY SENSOR TAPS FRAME SIZE MAIN / ARCING CONTACTS BATTERY STATUS PRIMARY DISCONNECTS CELL AND RACKING DEV. CLEAN/LUBE DESCRIPTION CLEAN/LUBECONDITION Acceptable Acceptable N/A N/A N/A ARC CHUTES SECONDARY DISCONNECT CONDITIONDESCRIPTION CLEAN/LUBE N/AN/A DESCRIPTION N/A N/A N/AOPERATING MECHANISM N/A PHASE BARRIERS N/A N/A N/AAUXILIARY DEVICES BLOWN FUSE INDICATOR N/A N/A N/AINTERLOCKS OVERALL CONDITION New CONDITION Acceptable N/A Acceptable Acceptable New BREAKER NAMEPLATE INSPECTION TARGETS 03001, REVISED 4/9/2015(888) 778-2733 www.schneider-electric.us D.O. N/A N/A N/A 17102MFR. DATE / CODE N/A SN / SO NO.Square D Micrologic 5.0A N/A COUNTER READING AL N/A FUSE AMPS N/A COUNTER READING AF RANGE @1000VGIG-OHMS 20°C 216.0 332.7 160.0 246.5 TEST 1 TEST 3 1.5404TEMPERATURE CORRECTION FACTOR TO 20°C, TCF TEST 2 INSULATION RESISTANCE IN:CLOSED: POLE-POLE 258.8168.0 20°C ACTUAL PH A ACTUALACTUAL A - B A-GND CLOSED: POLE-GROUND OPEN: LINE-LOAD 20°C PH B PH C B-GND C-GND B - C C - A 155.0 172.0 136.0 129.0 190.0 208.0209.5 238.8 320.4 264.9 198.7 292.7 CONTACT RESISTANCE - MICRO-OHMS 34 POLE 1 FUSE 2FUSE 1 FUSE 3 N/A N/A N/A POLE 3POLE 2 3232 1 .5 1.5 .1 2 2 2 1 .5 1.5 .1 1 .5 1.5 .1 LONG TIME DELAY SHORT TIME PICKUP SHORT TIME DELAY INSTANTANEOUS PICKUP GROUND FAULT PICKUP GROUND FAULT DELAY LONG TIME PICKUP AS FOUND SETTING AS TESTED SETTING AS LEFT SETTING I2T ON AS TESTED SETTING AS LEFT SETTING I*2 T ONAS FOUND SETTING CT / SENSOR TAP:RATING PLUG: OVERCURRENT SETTINGS CT / SENSOR RATINGS: AS FOUND RANGE MINIMUM MAXIMUM .036 5.046 .036 5.046 .036 5.046 .036 5.046 .036 5.046 .036 5.046 2,000 1,400 0 POLE 3 AS FOUNDAS FOUND AS LEFT AS LEFT 14.413 14.413 14.413 14.413 14.413 NT NT NT CURRENT MULTIPLE TEST AMPERES sec sec LONG TIME PICKUP LONG TIME DELAY 1,067MILLIVOLT DROP 14.413 SHORT TIME PICKUP SHORT TIME DELAY INSTANTANEOUS PICKUP INSTANTANEOUS DELAY GROUND FAULT PICKUP GROUND FAULT DELAY sec sec sec sec sec sec AS LEFT A A A A AA A A POLE 1 FUNCTION POLE 2TEST RESULTS BY SECONDARY INJECTION TECH NOTE(S): COMMENTS: DEFICIENCIES: ZONE INTLK BREAKER TYPE TRIP UNIT TYPE 0202307537480002 BKR INT. RATING MOUNTING HUMIDITY WO-04790545 LOW VOLTAGE POWER CIRCUIT BREAKER TEMPERATURE 85 °F PAGE END USER CUSTOMER Grapevine, TX 76051 GAYLORD TEXAN SITE LOCATION 7B Feeder 19DESIGNATION SUBSTATION Main DATE END USER ASSET/ID 8/22/2017 71 JOB # % DBID 7B Feeder 19 08-547650 DEVICE 03001 - SE LOW VOLT. PWR. CKT. BKR. TESTED BY EQUIPMENT USEDJames Jillson Sevondary Injection, Megger, Ductor 800 N/A N/A N/A MATCHES DWG OR SPEC GROUND CONNECTION ONPowerpact PJ 100 ka MANUFACTURER FUSE MFR. BKR CATALOG NO.PJA36080U43A N/AFUSE CAT. NO. 800 OFF B.I. THERMAL MEMORY SENSOR TAPS FRAME SIZE MAIN / ARCING CONTACTS BATTERY STATUS PRIMARY DISCONNECTS CELL AND RACKING DEV. CLEAN/LUBE DESCRIPTION CLEAN/LUBECONDITION Acceptable Acceptable N/A N/A N/A ARC CHUTES SECONDARY DISCONNECT CONDITIONDESCRIPTION CLEAN/LUBE N/AN/A DESCRIPTION N/A N/A N/AOPERATING MECHANISM N/A PHASE BARRIERS N/A N/A N/AAUXILIARY DEVICES BLOWN FUSE INDICATOR N/A N/A N/AINTERLOCKS OVERALL CONDITION New CONDITION Acceptable N/A Acceptable Acceptable N/A BREAKER NAMEPLATE INSPECTION TARGETS 03001, REVISED 4/9/2015(888) 778-2733 www.schneider-electric.us D.O. N/A N/A N/A 17091MFR. DATE / CODE N/A SN / SO NO.Square D Micrologic 5.0A N/A COUNTER READING AL N/A FUSE AMPS N/A COUNTER READING AF RANGE @1000VGIG-OHMS 20°C 203.0 312.7 156.0 240.3 TEST 1 TEST 3 1.5404TEMPERATURE CORRECTION FACTOR TO 20°C, TCF TEST 2 INSULATION RESISTANCE IN:CLOSED: POLE-POLE 246.5160.0 20°C ACTUAL PH A ACTUALACTUAL A - B A-GND CLOSED: POLE-GROUND OPEN: LINE-LOAD 20°C PH B PH C B-GND C-GND B - C C - A 177.0 159.0 143.0 142.0 182.0 190.0220.3 272.7 292.7 244.9 218.7 280.4 CONTACT RESISTANCE - MICRO-OHMS 31 POLE 1 FUSE 2FUSE 1 FUSE 3 N/A N/A N/A POLE 3POLE 2 3231 1 .5 1.5 .1 2 2 2 1 .5 1.5 .1 1 .5 1.5 .1 LONG TIME DELAY SHORT TIME PICKUP SHORT TIME DELAY INSTANTANEOUS PICKUP GROUND FAULT PICKUP GROUND FAULT DELAY LONG TIME PICKUP AS FOUND SETTING AS TESTED SETTING AS LEFT SETTING I2T ON AS TESTED SETTING AS LEFT SETTING I*2 T ONAS FOUND SETTING CT / SENSOR TAP:RATING PLUG: OVERCURRENT SETTINGS CT / SENSOR RATINGS: AS FOUND RANGE MINIMUM MAXIMUM .036 5.087 .036 .036 .036 .036 .036 .036 .036 .036 .036 .036 2,000 1,400 0 POLE 3 AS FOUNDAS FOUND AS LEFT AS LEFT 14.515 14.515 14.515 14.515 14.515 NT NT NT CURRENT MULTIPLE TEST AMPERES sec sec LONG TIME PICKUP LONG TIME DELAY 1,067MILLIVOLT DROP 14.515 SHORT TIME PICKUP SHORT TIME DELAY INSTANTANEOUS PICKUP INSTANTANEOUS DELAY GROUND FAULT PICKUP GROUND FAULT DELAY sec sec sec sec sec sec AS LEFT A A A A AA A A POLE 1 FUNCTION POLE 2TEST RESULTS BY SECONDARY INJECTION TECH NOTE(S): COMMENTS: DEFICIENCIES: ZONE INTLK BREAKER TYPE TRIP UNIT TYPE 085351560701 BKR INT. RATING MOUNTING HUMIDITY WO-04790545 LOW VOLTAGE POWER CIRCUIT BREAKER TEMPERATURE 85 °F PAGE END USER CUSTOMER Grapevine, TX 76051 GAYLORD TEXAN SITE LOCATION A2DESIGNATION SUBSTATION Main DATE END USER ASSET/ID 8/22/2017 71 JOB # % DBID A2 08-547530 DEVICE 03001 - SE LOW VOLT. PWR. CKT. BKR. TESTED BY EQUIPMENT USEDJames Jillson Sevondary Injection, Megger, Ductor 4000 N/A N/A N/A MATCHES DWG OR SPEC GROUND CONNECTION ONMasterpact NW 100 ka MANUFACTURER FUSE MFR. BKR CATALOG NO.WA6KKZ64A3SXFXXXXA N/AFUSE CAT. NO. 4000 OFF B.I. THERMAL MEMORY SENSOR TAPS FRAME SIZE MAIN / ARCING CONTACTS BATTERY STATUS PRIMARY DISCONNECTS CELL AND RACKING DEV. CLEAN/LUBE DESCRIPTION CLEAN/LUBECONDITION Acceptable Acceptable N/A N/A N/A ARC CHUTES SECONDARY DISCONNECT CONDITIONDESCRIPTION CLEAN/LUBE N/A N/A DESCRIPTION N/A N/A N/AOPERATING MECHANISM N/A PHASE BARRIERS N/A N/A N/AAUXILIARY DEVICES BLOWN FUSE INDICATOR N/A N/A N/AINTERLOCKS N/A N/A OVERALL CONDITION New CONDITION Acceptable Acceptable Acceptable N/A BREAKER NAMEPLATE INSPECTION TARGETS 03001, REVISED 4/9/2015(888) 778-2733 www.schneider-electric.us D.O. N/A N/A N/A 17102MFR. DATE / CODE N/A SN / SO NO.Square D Micrologic 6.0P N/A COUNTER READING AL N/A FUSE AMPS N/A COUNTER READING AF RANGE @1000VGIG-OHMS 20°C 168.0 258.8 141.0 217.2 TEST 1 TEST 3 1.5404TEMPERATURE CORRECTION FACTOR TO 20°C, TCF TEST 2 INSULATION RESISTANCE IN:CLOSED: POLE-POLE 195.6127.0 20°C ACTUAL PH A ACTUALACTUAL A - B A-GND CLOSED: POLE-GROUND OPEN: LINE-LOAD 20°C PH B PH C B-GND C-GND B - C C - A 139.0 152.0 120.0 153.0 209.0 177.0184.8 214.1 272.7 234.1 235.7 321.9 CONTACT RESISTANCE - MICRO-OHMS 13 POLE 1 FUSE 2FUSE 1 FUSE 3 N/A N/A N/A POLE 3POLE 2 1513 1 .5 1.5 .1 2 2 2 A .1 1 .5 1.5 .1 1 .5 1.5 .1 LONG TIME DELAY SHORT TIME PICKUP SHORT TIME DELAY INSTANTANEOUS PICKUP GROUND FAULT PICKUP GROUND FAULT DELAY LONG TIME PICKUP AS FOUND SETTING AS TESTED SETTING AS LEFT SETTING I2T ON AS TESTED SETTING AS LEFT SETTING I*2 T ONAS FOUND SETTING CT / SENSOR TAP:RATING PLUG: OVERCURRENT SETTINGS CT / SENSOR RATINGS: .1 .1 AA AS FOUND RANGE MINIMUM MAXIMUM .036 5.305 .276 .036 5.305 .276 .036 5.305 .276 .036 5.305 .276 .036 5.305 .276 .036 5.305 .276 10,000 7,000 1,000 POLE 3 AS FOUNDAS FOUND AS LEFT AS LEFT 14.880 14.880 14.880 14.880 14.880 NT NT NT CURRENT MULTIPLE TEST AMPERES sec sec LONG TIME PICKUP LONG TIME DELAY 5,333MILLIVOLT DROP 14.880 SHORT TIME PICKUP SHORT TIME DELAY INSTANTANEOUS PICKUP INSTANTANEOUS DELAY GROUND FAULT PICKUP GROUND FAULT DELAY sec sec sec sec sec sec AS LEFT A A A A AA A A POLE 1 FUNCTION POLE 2TEST RESULTS BY SECONDARY INJECTION TECH NOTE(S): COMMENTS: DEFICIENCIES: HUMIDITY WO-04790545 Low Voltage Ground Fault Relay TEMPERATURE 95 °F PAGE END USER CUSTOMER Grapevine, TX 76051 GAYLORD TEXAN SITE LOCATION A2 GroundfaultDESIGNATION SUBSTATION Main DATE END USER ASSET/ID 8/25/2017 85 JOB # % DBID A2 Groundfault 08-548800 DEVICE 08001 - SE LV Ground Fault System TESTED BY EQUIPMENT USEDJames Jillson Current source RESIDUAL GROUND ZERO-SEQUENCE SOURCE GROUND 486 B PHASE 502 C PHASE 497 NEUTRAL PRIMARY INJECTION TESTING CURVE LIMITS (time)TIME DELAY MINIMUM MAXIMUM SECONDS CYCLES TEST CURRENT TEST % PICK- UP CURRENT amps500 150 200 300 750 amps amps1,000 amps1,500 1.1 .23 .55 .61 .26 1.18 N/A N/A N/A2 .38 .95 N/A AFTER TEST N/A INSULATION RESISTANCE NEU. TO GND. @1kV D.C. BEFORE TEST S48891 PICK-UP CURRENT INT. RATING SN / SO NO. 17102 N/A MATCHES DWG OR SPEC GROUND CONNECTION 480 / 277 100 ka MANUFACTURER CATALOG NO. RATED CURRENT MONITOR / TEST PANEL CLEAN/LUBE DESCRIPTION CLEAN/LUBECONDITION AcceptableN/A Solid N/A CONDITIONDESCRIPTION CLEAN/LUBE N/ANo DESCRIPTION N/A N/A CT WINDOW SHAPE Rectangular N/A Acceptable N/A New CONDITION Acceptable N/AAcceptable RELAY NAMEPLATE N/A MANUF. DATE TYPE RATED VOLTAGE 4000 085351560701 Wa6KKZ64A3SXFXXXXA GROUND FAULT SYSTEM TYPE OVERALL CONDITION MULTIPLE SOURCE SCHEME CT WINDOW TYPE MAIN BONDING JUMPER ZONE INTERLOCKS CONTROL POWER XFMR CONDUCTOR ROUTING N/A N/A INSPECTION N/A N/A N/A N/A N/A DESCRIPTION TESTS POLARITY TEST OPTIONAL: CONTROL TEST AT 55% VOLTAGE DESCRIPTION SETTINGS PICK-UP SETTING TIME DELAY SETTING INJECTION TEST DATA A PHASE 08001, REVISED 4/8/2015(888) 778-2733 www.schneider-electric.us .1 A Schneider Electric RANGE TECH NOTE(S): COMMENTS: DEFICIENCIES: ZONE INTLK BREAKER TYPE TRIP UNIT TYPE 0202308727340001 BKR INT. RATING MOUNTING HUMIDITY WO-04790545 LOW VOLTAGE POWER CIRCUIT BREAKER TEMPERATURE 85 °F PAGE END USER CUSTOMER Grapevine, TX 76051 GAYLORD TEXAN SITE LOCATION A3DESIGNATION SUBSTATION Main DATE END USER ASSET/ID 8/22/2017 71 JOB # % DBID A3 08-547590 DEVICE 03001 - SE LOW VOLT. PWR. CKT. BKR. TESTED BY EQUIPMENT USEDJames Jillson Sevondary Injection, Megger, Ductor 2000 N/A N/A N/A MATCHES DWG OR SPEC GROUND CONNECTION ONPowerpact R Frame 65 ka MANUFACTURER FUSE MFR. BKR CATALOG NO.RKF36200U64AE1 N/AFUSE CAT. NO. 2000 OFF B.I. THERMAL MEMORY SENSOR TAPS FRAME SIZE MAIN / ARCING CONTACTS BATTERY STATUS PRIMARY DISCONNECTS CELL AND RACKING DEV. CLEAN/LUBE DESCRIPTION CLEAN/LUBECONDITION Acceptable Acceptable N/A N/A N/A ARC CHUTES SECONDARY DISCONNECT CONDITIONDESCRIPTION CLEAN/LUBE N/AAcceptable DESCRIPTION N/A N/A N/AOPERATING MECHANISM N/A PHASE BARRIERS Acceptable N/A N/AAUXILIARY DEVICES BLOWN FUSE INDICATOR N/A N/A N/AINTERLOCKS OVERALL CONDITION New CONDITION Acceptable N/A Acceptable Acceptable N/A BREAKER NAMEPLATE INSPECTION TARGETS 03001, REVISED 4/9/2015(888) 778-2733 www.schneider-electric.us D.O. N/A N/A N/A 17086MFR. DATE / CODE N/A SN / SO NO.Square D Micrologic 6.0P N/A COUNTER READING AL N/A FUSE AMPS N/A COUNTER READING AF RANGE @1000VGIG-OHMS 20°C 195.0 300.4 143.0 220.3 TEST 1 TEST 3 1.5404TEMPERATURE CORRECTION FACTOR TO 20°C, TCF TEST 2 INSULATION RESISTANCE IN:CLOSED: POLE-POLE 258.8168.0 20°C ACTUAL PH A ACTUALACTUAL A - B A-GND CLOSED: POLE-GROUND OPEN: LINE-LOAD 20°C PH B PH C B-GND C-GND B - C C - A 159.0 161.0 135.0 128.0 206.0 221.0208.0 244.9 340.4 248.0 197.2 317.3 CONTACT RESISTANCE - MICRO-OHMS 23 POLE 1 FUSE 2FUSE 1 FUSE 3 N/A N/A N/A POLE 3POLE 2 2424 1 .5 1.5 .1 2 2 2 A .1 1 .5 1.5 .1 1 .5 1.5 .1 LONG TIME DELAY SHORT TIME PICKUP SHORT TIME DELAY INSTANTANEOUS PICKUP GROUND FAULT PICKUP GROUND FAULT DELAY LONG TIME PICKUP AS FOUND SETTING AS TESTED SETTING AS LEFT SETTING I2T ON AS TESTED SETTING AS LEFT SETTING I*2 T ONAS FOUND SETTING CT / SENSOR TAP:RATING PLUG: OVERCURRENT SETTINGS CT / SENSOR RATINGS: .1 .1 AA AS FOUND RANGE MINIMUM MAXIMUM .037 4.937 .145 .037 4.937 .145 .037 4.937 .145 .037 4.937 .145 .037 4.937 .145 .037 4.937 .145 5,000 3,500 1,000 POLE 3 AS FOUNDAS FOUND AS LEFT AS LEFT 14.012 14.012 14.012 14.012 14.012 NT NT NT CURRENT MULTIPLE TEST AMPERES sec sec LONG TIME PICKUP LONG TIME DELAY 2,667MILLIVOLT DROP 14.012 SHORT TIME PICKUP SHORT TIME DELAY INSTANTANEOUS PICKUP INSTANTANEOUS DELAY GROUND FAULT PICKUP GROUND FAULT DELAY sec sec sec sec sec sec AS LEFT A A A A AA A A POLE 1 FUNCTION POLE 2TEST RESULTS BY SECONDARY INJECTION TECH NOTE(S): COMMENTS: DEFICIENCIES: HUMIDITY WO-04790545 Low Voltage Ground Fault Relay TEMPERATURE 95 °F PAGE END USER CUSTOMER Grapevine, TX 76051 GAYLORD TEXAN SITE LOCATION A3 GroundfaultDESIGNATION SUBSTATION Main DATE END USER ASSET/ID 8/25/2017 85 JOB # % DBID A3 Groundfault 08-548820 DEVICE 08001 - SE LV Ground Fault System TESTED BY EQUIPMENT USEDJames Jillson Current Source RESIDUAL GROUND ZERO-SEQUENCE SOURCE GROUND 496 B PHASE 498 C PHASE 503 NEUTRAL PRIMARY INJECTION TESTING CURVE LIMITS (time)TIME DELAY MINIMUM MAXIMUM SECONDS CYCLES TEST CURRENT TEST % PICK- UP CURRENT amps500 150 200 300 750 amps amps1,000 amps1,500 1.1 .23 .55 .64 .25 1.26 N/A N/A N/A2 .38 .95 N/A AFTER TEST N/A INSULATION RESISTANCE NEU. TO GND. @1kV D.C. BEFORE TEST S48896 PICK-UP CURRENT INT. RATING SN / SO NO. 17102 N/A MATCHES DWG OR SPEC GROUND CONNECTION 480 / 277 100 ka MANUFACTURER CATALOG NO. RATED CURRENT MONITOR / TEST PANEL CLEAN/LUBE DESCRIPTION CLEAN/LUBECONDITION AcceptableN/A Solid N/A CONDITIONDESCRIPTION CLEAN/LUBE N/AN/A DESCRIPTION N/A N/A CT WINDOW SHAPE Rectangular N/A Acceptable N/A New CONDITION Acceptable N/AAcceptable RELAY NAMEPLATE N/A MANUF. DATE TYPE RATED VOLTAGE 2000 N/A N/A GROUND FAULT SYSTEM TYPE OVERALL CONDITION MULTIPLE SOURCE SCHEME CT WINDOW TYPE MAIN BONDING JUMPER ZONE INTERLOCKS CONTROL POWER XFMR CONDUCTOR ROUTING INSPECTION N/A N/A N/A N/A N/A DESCRIPTION TESTS POLARITY TEST OPTIONAL: CONTROL TEST AT 55% VOLTAGE DESCRIPTION SETTINGS PICK-UP SETTING TIME DELAY SETTING INJECTION TEST DATA A PHASE 08001, REVISED 4/8/2015(888) 778-2733 www.schneider-electric.us .1 A Schneider Electric RANGE TECH NOTE(S): COMMENTS: DEFICIENCIES: ZONE INTLK BREAKER TYPE TRIP UNIT TYPE 0202308576120001 BKR INT. RATING MOUNTING HUMIDITY WO-04790545 LOW VOLTAGE POWER CIRCUIT BREAKER TEMPERATURE 85 °F PAGE END USER CUSTOMER Grapevine, TX 76051 GAYLORD TEXAN SITE LOCATION A4 FeederDESIGNATION SUBSTATION Main DATE END USER ASSET/ID 8/22/2017 71 JOB # % DBID A4 Feeder 08-547630 DEVICE 03001 - SE LOW VOLT. PWR. CKT. BKR. TESTED BY EQUIPMENT USEDJames Jillson Sevondary Injection, Megger, Ductor 1200 N/A N/A N/A MATCHES DWG OR SPEC GROUND CONNECTION ONPowerpact PJ 100 ka MANUFACTURER FUSE MFR. BKR CATALOG NO.PJA36120U64AE1 N/AFUSE CAT. NO. 1200 OFF B.I. THERMAL MEMORY SENSOR TAPS FRAME SIZE MAIN / ARCING CONTACTS BATTERY STATUS PRIMARY DISCONNECTS CELL AND RACKING DEV. CLEAN/LUBE DESCRIPTION CLEAN/LUBECONDITION Acceptable Acceptable N/A N/A N/A ARC CHUTES SECONDARY DISCONNECT CONDITIONDESCRIPTION CLEAN/LUBE N/AN/A DESCRIPTION N/A N/A N/AOPERATING MECHANISM N/A PHASE BARRIERS N/A N/A N/AAUXILIARY DEVICES BLOWN FUSE INDICATOR N/A N/A N/AINTERLOCKS OVERALL CONDITION New CONDITION Acceptable N/A Acceptable Acceptable N/A BREAKER NAMEPLATE INSPECTION TARGETS 03001, REVISED 4/9/2015(888) 778-2733 www.schneider-electric.us D.O. N/A N/A N/A 17102MFR. DATE / CODE N/A SN / SO NO.Square D Micrologic 6.0P N/A COUNTER READING AL N/A FUSE AMPS N/A COUNTER READING AF RANGE @1000VGIG-OHMS 20°C 202.0 311.2 134.0 206.4 TEST 1 TEST 3 1.5404TEMPERATURE CORRECTION FACTOR TO 20°C, TCF TEST 2 INSULATION RESISTANCE IN:CLOSED: POLE-POLE 181.8118.0 20°C ACTUAL PH A ACTUALACTUAL A - B A-GND CLOSED: POLE-GROUND OPEN: LINE-LOAD 20°C PH B PH C B-GND C-GND B - C C - A 137.0 140.0 125.0 147.0 181.0 173.0192.6 211.0 266.5 215.7 226.4 278.8 CONTACT RESISTANCE - MICRO-OHMS 28 POLE 1 FUSE 2FUSE 1 FUSE 3 N/A N/A N/A POLE 3POLE 2 2928 1 .5 1.5 .1 2 2 2 A .1 1 .5 1.5 .1 1 .5 1.5 .1 LONG TIME DELAY SHORT TIME PICKUP SHORT TIME DELAY INSTANTANEOUS PICKUP GROUND FAULT PICKUP GROUND FAULT DELAY LONG TIME PICKUP AS FOUND SETTING AS TESTED SETTING AS LEFT SETTING I2T ON AS TESTED SETTING AS LEFT SETTING I*2 T ONAS FOUND SETTING CT / SENSOR TAP:RATING PLUG: OVERCURRENT SETTINGS CT / SENSOR RATINGS: .1 .1 AA AS FOUND RANGE MINIMUM MAXIMUM .034 5.204 .645 .034 5.204 .645 .034 5.204 .645 .034 5.204 .645 .034 5.204 .645 .034 5.204 .645 3,000 2,100 480 POLE 3 AS FOUNDAS FOUND AS LEFT AS LEFT 14.846 14.846 14.846 14.846 14.846 NT NT NT CURRENT MULTIPLE TEST AMPERES sec sec LONG TIME PICKUP LONG TIME DELAY 1,600MILLIVOLT DROP 14.846 SHORT TIME PICKUP SHORT TIME DELAY INSTANTANEOUS PICKUP INSTANTANEOUS DELAY GROUND FAULT PICKUP GROUND FAULT DELAY sec sec sec sec sec sec AS LEFT A A A A AA A A POLE 1 FUNCTION POLE 2TEST RESULTS BY SECONDARY INJECTION TECH NOTE(S): COMMENTS: DEFICIENCIES: ZONE INTLK BREAKER TYPE TRIP UNIT TYPE 085351560801 BKR INT. RATING MOUNTING HUMIDITY WO-04790545 LOW VOLTAGE POWER CIRCUIT BREAKER TEMPERATURE 85 °F PAGE END USER CUSTOMER Grapevine, TX 76051 GAYLORD TEXAN SITE LOCATION B6DESIGNATION SUBSTATION Main DATE END USER ASSET/ID 8/22/2017 71 JOB # % DBID B2 08-547540 DEVICE 03001 - SE LOW VOLT. PWR. CKT. BKR. TESTED BY EQUIPMENT USEDJames Jillson Sevondary Injection, Megger, Ductor 4000 N/A N/A N/A MATCHES DWG OR SPEC GROUND CONNECTION ONMasterpact NW 100 ka MANUFACTURER FUSE MFR. BKR CATALOG NO.WA6KKZ43A9SXXXXXXA N/AFUSE CAT. NO. 4000 OFF B.I. THERMAL MEMORY SENSOR TAPS FRAME SIZE MAIN / ARCING CONTACTS BATTERY STATUS PRIMARY DISCONNECTS CELL AND RACKING DEV. CLEAN/LUBE DESCRIPTION CLEAN/LUBECONDITION Acceptable Acceptable New New N/A ARC CHUTES SECONDARY DISCONNECT CONDITIONDESCRIPTION CLEAN/LUBE N/AN/A DESCRIPTION N/A N/A N/AOPERATING MECHANISM N/A PHASE BARRIERS N/A N/A N/AAUXILIARY DEVICES BLOWN FUSE INDICATOR N/A N/A N/AINTERLOCKS OVERALL CONDITION New CONDITION Acceptable N/A Acceptable Acceptable N/A BREAKER NAMEPLATE INSPECTION TARGETS 03001, REVISED 4/9/2015(888) 778-2733 www.schneider-electric.us D.O. N/A N/A N/A 17101MFR. DATE / CODE N/A SN / SO NO.Square D Micrologic 5.0A N/A COUNTER READING AL N/A FUSE AMPS N/A COUNTER READING AF RANGE @1000VGIG-OHMS 20°C 173.0 266.5 149.0 229.5 TEST 1 TEST 3 1.5404TEMPERATURE CORRECTION FACTOR TO 20°C, TCF TEST 2 INSULATION RESISTANCE IN:CLOSED: POLE-POLE 238.8155.0 20°C ACTUAL PH A ACTUALACTUAL A - B A-GND CLOSED: POLE-GROUND OPEN: LINE-LOAD 20°C PH B PH C B-GND C-GND B - C C - A 138.0 146.0 142.0 132.0 192.0 180.0218.7 212.6 277.3 224.9 203.3 295.8 CONTACT RESISTANCE - MICRO-OHMS 15 POLE 1 FUSE 2FUSE 1 FUSE 3 N/A N/A N/A POLE 3POLE 2 1313 1 .5 1.5 .1 2 2 2 1 .5 1.5 .1 1 .5 1.5 .1 LONG TIME DELAY SHORT TIME PICKUP SHORT TIME DELAY INSTANTANEOUS PICKUP GROUND FAULT PICKUP GROUND FAULT DELAY LONG TIME PICKUP AS FOUND SETTING AS TESTED SETTING AS LEFT SETTING I2T ON AS TESTED SETTING AS LEFT SETTING I*2 T ONAS FOUND SETTING CT / SENSOR TAP:RATING PLUG: OVERCURRENT SETTINGS CT / SENSOR RATINGS: AS FOUND RANGE MINIMUM MAXIMUM .037 5.312 .037 5.312 .037 5.312 .037 5.312 .037 5.312 .037 5.312 10,000 7,000 0 POLE 3 AS FOUNDAS FOUND AS LEFT AS LEFT 14.895 14.895 14.895 14.895 14.895 NT NT NT CURRENT MULTIPLE TEST AMPERES sec sec LONG TIME PICKUP LONG TIME DELAY 5,333MILLIVOLT DROP 14.895 SHORT TIME PICKUP SHORT TIME DELAY INSTANTANEOUS PICKUP INSTANTANEOUS DELAY GROUND FAULT PICKUP GROUND FAULT DELAY sec sec sec sec sec sec AS LEFT A A A A AA A A POLE 1 FUNCTION POLE 2TEST RESULTS BY SECONDARY INJECTION TECH NOTE(S): COMMENTS: DEFICIENCIES: HUMIDITY WO-04790545 Low Voltage Ground Fault Relay TEMPERATURE 95 °F PAGE END USER CUSTOMER Grapevine, TX 76051 GAYLORD TEXAN SITE LOCATION B6 GroundfaultDESIGNATION SUBSTATION Main DATE END USER ASSET/ID 8/25/2017 85 JOB # % DBID B6 Groundfault 08-548810 DEVICE 08001 - SE LV Ground Fault System TESTED BY EQUIPMENT USEDJames Jillson Current Source RESIDUAL GROUND ZERO-SEQUENCE SOURCE GROUND 500 B PHASE 502 C PHASE 496 NEUTRAL PRIMARY INJECTION TESTING CURVE LIMITS (time)TIME DELAY MINIMUM MAXIMUM SECONDS CYCLES TEST CURRENT TEST % PICK- UP CURRENT amps500 150 200 300 750 amps amps1,000 amps1,500 1.1 .23 .55 .58 .31 1.42 N/A N/A N/A2 .38 .95 N/A AFTER TEST N/A INSULATION RESISTANCE NEU. TO GND. @1kV D.C. BEFORE TEST S48891 PICK-UP CURRENT INT. RATING SN / SO NO. 17102 N/A MATCHES DWG OR SPEC GROUND CONNECTION 480 / 277 100 ka MANUFACTURER CATALOG NO. RATED CURRENT MONITOR / TEST PANEL CLEAN/LUBE DESCRIPTION CLEAN/LUBECONDITION AcceptableN/A Solid N/A CONDITIONDESCRIPTION CLEAN/LUBE N/AN/A DESCRIPTION N/A N/A CT WINDOW SHAPE Rectangular Acceptable N/A New CONDITION Acceptable N/AAcceptable RELAY NAMEPLATE N/A MANUF. DATE TYPE RATED VOLTAGE 4000 085351560701 Wa6KKZ64A3SXFXXXXA GROUND FAULT SYSTEM TYPE OVERALL CONDITION MULTIPLE SOURCE SCHEME CT WINDOW TYPE MAIN BONDING JUMPER ZONE INTERLOCKS CONTROL POWER XFMR CONDUCTOR ROUTING INSPECTION N/A N/A N/A N/A N/A DESCRIPTION TESTS POLARITY TEST OPTIONAL: CONTROL TEST AT 55% VOLTAGE DESCRIPTION SETTINGS PICK-UP SETTING TIME DELAY SETTING INJECTION TEST DATA A PHASE 08001, REVISED 4/8/2015(888) 778-2733 www.schneider-electric.us .1 A Schneider Electric RANGE TECH NOTE(S): COMMENTS: DEFICIENCIES: ZONE INTLK BREAKER TYPE TRIP UNIT TYPE 085351560401 BKR INT. RATING MOUNTING HUMIDITY WO-04790545 LOW VOLTAGE POWER CIRCUIT BREAKER TEMPERATURE 85 °F PAGE END USER CUSTOMER Grapevine, TX 76051 GAYLORD TEXAN SITE LOCATION B8DESIGNATION SUBSTATION Main DATE END USER ASSET/ID 8/22/2017 71 JOB # % DBID B8 08-547550 DEVICE 03001 - SE LOW VOLT. PWR. CKT. BKR. TESTED BY EQUIPMENT USEDJames Jillson Sevondary Injection, Megger, Ductor 4000 N/A N/A N/A MATCHES DWG OR SPEC GROUND CONNECTION ONMasterpact NW 100 ka MANUFACTURER FUSE MFR. BKR CATALOG NO.WA6KKZ64A3SXFXXXXA N/AFUSE CAT. NO. 4000 OFF B.I. THERMAL MEMORY SENSOR TAPS FRAME SIZE MAIN / ARCING CONTACTS BATTERY STATUS PRIMARY DISCONNECTS CELL AND RACKING DEV. CLEAN/LUBE DESCRIPTION CLEAN/LUBECONDITION Acceptable Acceptable N/A New N/A ARC CHUTES SECONDARY DISCONNECT CONDITIONDESCRIPTION CLEAN/LUBE N/AN/A DESCRIPTION N/A N/A N/AOPERATING MECHANISM N/A PHASE BARRIERS N/A N/A N/AAUXILIARY DEVICES BLOWN FUSE INDICATOR N/A N/A N/AINTERLOCKS OVERALL CONDITION New CONDITION Acceptable N/A Acceptable Acceptable N/A BREAKER NAMEPLATE INSPECTION TARGETS 03001, REVISED 4/9/2015(888) 778-2733 www.schneider-electric.us D.O. N/A N/A N/A 17101MFR. DATE / CODE N/A SN / SO NO.Square D Micrologic 6.0P N/A COUNTER READING AL N/A FUSE AMPS N/A COUNTER READING AF RANGE @1000VGIG-OHMS 20°C 190.0 292.7 162.0 249.5 TEST 1 TEST 3 1.5404TEMPERATURE CORRECTION FACTOR TO 20°C, TCF TEST 2 INSULATION RESISTANCE IN:CLOSED: POLE-POLE 246.5160.0 20°C ACTUAL PH A ACTUALACTUAL A - B A-GND CLOSED: POLE-GROUND OPEN: LINE-LOAD 20°C PH B PH C B-GND C-GND B - C C - A 168.0 171.0 158.0 177.0 204.0 219.0243.4 258.8 337.3 263.4 272.7 314.2 CONTACT RESISTANCE - MICRO-OHMS 15 POLE 1 FUSE 2FUSE 1 FUSE 3 N/A N/A N/A POLE 3POLE 2 1415 1 .5 1.5 .1 2 2 2 A .1 1 .5 1.5 .1 1 .5 1.5 .1 LONG TIME DELAY SHORT TIME PICKUP SHORT TIME DELAY INSTANTANEOUS PICKUP GROUND FAULT PICKUP GROUND FAULT DELAY LONG TIME PICKUP AS FOUND SETTING AS TESTED SETTING AS LEFT SETTING I2T ON AS TESTED SETTING AS LEFT SETTING I*2 T ONAS FOUND SETTING CT / SENSOR TAP:RATING PLUG: OVERCURRENT SETTINGS CT / SENSOR RATINGS: .1 .1 AA AS FOUND RANGE MINIMUM MAXIMUM .036 5.422 .279 .036 5.422 .279 .036 5.422 .279 .036 5.422 .279 .036 5.422 .279 .036 5.422 .279 10,000 7,000 1,000 POLE 3 AS FOUNDAS FOUND AS LEFT AS LEFT 15.179 15.179 15.179 15.179 15.179 NT NT NT CURRENT MULTIPLE TEST AMPERES sec sec LONG TIME PICKUP LONG TIME DELAY 5,333MILLIVOLT DROP 15.179 SHORT TIME PICKUP SHORT TIME DELAY INSTANTANEOUS PICKUP INSTANTANEOUS DELAY GROUND FAULT PICKUP GROUND FAULT DELAY sec sec sec sec sec sec AS LEFT A A A A AA A A POLE 1 FUNCTION POLE 2TEST RESULTS BY SECONDARY INJECTION TECH NOTE(S): COMMENTS: DEFICIENCIES: ZONE INTLK BREAKER TYPE TRIP UNIT TYPE 0202308725740001 BKR INT. RATING MOUNTING HUMIDITY WO-04790545 LOW VOLTAGE POWER CIRCUIT BREAKER TEMPERATURE 85 °F PAGE END USER CUSTOMER Grapevine, TX 76051 GAYLORD TEXAN SITE LOCATION B9DESIGNATION SUBSTATION Main DATE END USER ASSET/ID 8/22/2017 71 JOB # % DBID B9 08-547560 DEVICE 03001 - SE LOW VOLT. PWR. CKT. BKR. TESTED BY EQUIPMENT USEDJames Jillson Sevondary Injection, Megger, Ductor 2000 N/A N/A N/A MATCHES DWG OR SPEC GROUND CONNECTION ONPowerpact R Frame 65 ka MANUFACTURER FUSE MFR. BKR CATALOG NO.RKF36200U64AE1 N/AFUSE CAT. NO. 2000 OFF B.I. THERMAL MEMORY SENSOR TAPS FRAME SIZE MAIN / ARCING CONTACTS BATTERY STATUS PRIMARY DISCONNECTS CELL AND RACKING DEV. CLEAN/LUBE DESCRIPTION CLEAN/LUBECONDITION Acceptable Acceptable N/A N/A N/A ARC CHUTES SECONDARY DISCONNECT CONDITIONDESCRIPTION CLEAN/LUBE N/AAcceptable DESCRIPTION N/A N/A N/AOPERATING MECHANISM N/A PHASE BARRIERS Acceptable N/A N/AAUXILIARY DEVICES BLOWN FUSE INDICATOR N/A N/A N/AINTERLOCKS OVERALL CONDITION New CONDITION Acceptable N/A Acceptable Acceptable N/A BREAKER NAMEPLATE INSPECTION TARGETS 03001, REVISED 4/9/2015(888) 778-2733 www.schneider-electric.us D.O. N/A N/A N/A 17086MFR. DATE / CODE N/A SN / SO NO.Square D Micrologic 6.0P N/A COUNTER READING AL N/A FUSE AMPS N/A COUNTER READING AF RANGE @1000VGIG-OHMS 20°C 243.0 374.3 180.0 277.3 TEST 1 TEST 3 1.5404TEMPERATURE CORRECTION FACTOR TO 20°C, TCF TEST 2 INSULATION RESISTANCE IN:CLOSED: POLE-POLE 204.9133.0 20°C ACTUAL PH A ACTUALACTUAL A - B A-GND CLOSED: POLE-GROUND OPEN: LINE-LOAD 20°C PH B PH C B-GND C-GND B - C C - A 121.0 147.0 172.0 154.0 198.0 226.0264.9 186.4 348.1 226.4 237.2 305.0 CONTACT RESISTANCE - MICRO-OHMS 26 POLE 1 FUSE 2FUSE 1 FUSE 3 N/A N/A N/A POLE 3POLE 2 2426 1 .5 1.5 .1 2 2 2 A .1 1 .5 1.5 .1 1 .5 1.5 .1 LONG TIME DELAY SHORT TIME PICKUP SHORT TIME DELAY INSTANTANEOUS PICKUP GROUND FAULT PICKUP GROUND FAULT DELAY LONG TIME PICKUP AS FOUND SETTING AS TESTED SETTING AS LEFT SETTING I2T ON AS TESTED SETTING AS LEFT SETTING I*2 T ONAS FOUND SETTING CT / SENSOR TAP:RATING PLUG: OVERCURRENT SETTINGS CT / SENSOR RATINGS: .1 .1 AA AS FOUND RANGE MINIMUM MAXIMUM .035 5.005 .144 .035 5.005 .144 .035 5.005 .144 .035 5.005 .144 .035 5.005 .144 .035 5.005 .144 5,000 3,500 1,000 POLE 3 AS FOUNDAS FOUND AS LEFT AS LEFT 14.155 14.155 14.155 14.155 14.155 NT NT NT CURRENT MULTIPLE TEST AMPERES sec sec LONG TIME PICKUP LONG TIME DELAY 2,667MILLIVOLT DROP 14.155 SHORT TIME PICKUP SHORT TIME DELAY INSTANTANEOUS PICKUP INSTANTANEOUS DELAY GROUND FAULT PICKUP GROUND FAULT DELAY sec sec sec sec sec sec AS LEFT A A A A AA A A POLE 1 FUNCTION POLE 2TEST RESULTS BY SECONDARY INJECTION TECH NOTE(S): COMMENTS: DEFICIENCIES: HUMIDITY WO-04790545 Low Voltage Ground Fault Relay TEMPERATURE 95 °F PAGE END USER CUSTOMER Grapevine, TX 76051 GAYLORD TEXAN SITE LOCATION B9 GroundfaultDESIGNATION SUBSTATION Main DATE END USER ASSET/ID 8/25/2017 85 JOB # % DBID B9 Groundfault 08-548820 DEVICE 08001 - SE LV Ground Fault System TESTED BY EQUIPMENT USEDJames Jillson Current Source RESIDUAL GROUND ZERO-SEQUENCE SOURCE GROUND 497 B PHASE 500 C PHASE 503 NEUTRAL PRIMARY INJECTION TESTING CURVE LIMITS (time)TIME DELAY MINIMUM MAXIMUM SECONDS CYCLES TEST CURRENT TEST % PICK- UP CURRENT amps500 150 200 300 750 amps amps1,000 amps1,500 1.1 .23 .55 .68 .29 1.26 N/A N/A N/A2 .38 .95 N/A AFTER TEST N/A INSULATION RESISTANCE NEU. TO GND. @1kV D.C. BEFORE TEST S48896 PICK-UP CURRENT INT. RATING SN / SO NO. 17102 N/A MATCHES DWG OR SPEC GROUND CONNECTION 480 / 277 100 ka MANUFACTURER CATALOG NO. RATED CURRENT MONITOR / TEST PANEL CLEAN/LUBE DESCRIPTION CLEAN/LUBECONDITION AcceptableN/A Solid N/A CONDITIONDESCRIPTION CLEAN/LUBE N/AN/A DESCRIPTION N/A N/A CT WINDOW SHAPE Rectangular N/A Acceptable N/A Acceptable CONDITION Acceptable N/AAcceptable RELAY NAMEPLATE N/A MANUF. DATE TYPE RATED VOLTAGE 4000 085351560701 Wa6KKZ64A3SXFXXXXA GROUND FAULT SYSTEM TYPE OVERALL CONDITION MULTIPLE SOURCE SCHEME CT WINDOW TYPE MAIN BONDING JUMPER ZONE INTERLOCKS CONTROL POWER XFMR CONDUCTOR ROUTING INSPECTION N/A N/A N/A N/A N/A DESCRIPTION TESTS POLARITY TEST OPTIONAL: CONTROL TEST AT 55% VOLTAGE DESCRIPTION SETTINGS PICK-UP SETTING TIME DELAY SETTING INJECTION TEST DATA A PHASE 08001, REVISED 4/8/2015(888) 778-2733 www.schneider-electric.us .1 A Schneider Electric RANGE TECH NOTE(S): COMMENTS: DEFICIENCIES: HUMIDITY WO-04790545 TWO-WINDING DRY-TYPE TRANSFORMER TEMPERATURE 96 °F PAGE END USER CUSTOMER Grapevine, TX 76051 GAYLORD TEXAN SITE LOCATION MCV-A TransformerDESIGNATION SUBSTATION Main DATE END USER ASSET/ID 8/22/2017 75 JOB # % DBID MCV-A Transformer 08-547560 DEVICE 23210 - SE DRY TYPE TRANSFORMER TESTED BY EQUIPMENT USEDJames Jillson TTR, Megger Acceptable CONDITIONDESCRIPTION CLEAN/LUBEDESCRIPTION N/A N/A N/A N/A N/A Acceptable N/A FANS N/AAcceptable Acceptable N/A N/A N/A N/A N/AVENTILATION / FILTERS N/A PAINT New INDOOR N/ANew N/A MATCHES DWG OR SPEC WEATHER N/A ENVIRONMENT Acceptable N/A GAUGES SUPPORT INSULATORS N/AN/A N/A WINDINGS Acceptable N/A CABINET HEATERS AUXILIARY DEVICES N/AN/A PRIMARY CONNECTIONS TANK / FRAME GROUND NEUTRAL GROUND DESCRIPTION CONDITION SEC. CONNECTIONS Acceptable N/A N/A N/A N/A N/A ARRESTERS CORE GROUND ALARMS / ANNUNCIATOR CONTROLS BUSHINGS CLEAN/LUBE CLEAN/LUBECONDITION TEMPERATURE GAUGES WERE RESETunavailable°CMAXIMUM WINDING TEMPERATURE (1)°CunavailableWINDING TEMPERATURE (1) GAUGES N/A CONTROLLED 23210, REVISED 10/27/2016(888) 778-2733 www.schneider-electric.us / / 1 30 NAMEPLATE DATA RATED CURRENT RATED CURRENT AMPERES AMPERES/ 23,693 3 4 5 kV PRI. PRIMARY VOLTAGE SECONDARY VOLTAGE 277 WYE 26,187 TAP POSITION/CONNECTION 25,564 24,317 25 CLASS 110 24,940 PHASE 337637568-137-01-1SERIAL NO. kVA/ / THERMAL RATINGS DELTA kV SEC. IMPEDANCE 17200 30 % YEAR OF MANUF.TX05061001 2017 MANUFACTURER SPECIFICATION NO.MANUF. LOCATION TYPE AA K FACTOR N/A °CTEMPERATURE RISE Bland, Va 1505.88 B.I.L. RATINGWINDING MATERIAL Cu LB DELTA480 TAP VOLTAGES / WINDING POLARITY SUBTRACTIVE WYE / 1 24,940 2 TOTAL WEIGHT Dry Schneider Electric RANGE INSPECTION INSULATION RESISTANCE TEST TESTED PRIMARY TO SECONDARY AND GROUND SECONDARY TO PRIMARY AND GROUND VOLTAGE (VOLTS DC) (MEGOHMS) WINDINGS TEST RESISTANCE PRIMARY AND SECONDARY TO GROUND 1.0 MINUTE0.5 MINUTE 0.5 MIN. 20C 1.0 MIN. 20C DIELECTRIC ABSORPTION RATIO TEMPERATURE CORRECTION FACTOR TO 20°C, TCF 2.06 5,000 1,000 5,000 112.00 230.72 139.00 286.34 341.96166.00304.88148.00 131.00 269.86 147.00 302.82 1.24 1.12 1.12 CALCULATED PASS/FAIL CALCULATED PASS/FAIL TO % DEVIATIONMEASURED TO % DEVIATIONMEASURED TO % DEVIATIONMEASURED TRANSFORMER TURNS RATIO TESTS CALCULATED PASS/FAIL CALC. RATIO SECONDARY VOLTAGE ENTER PRIMARY VOLTAGE X1 - X0 X3 - X1 H1 - H3 H2 - H1 H3 - H2 X0 - X1 TAP TO TEST 1 94.795 94.782 94.7660.31 %PASS 0.29 %PASSPASS94.491 0.32 %26,187 277 2 92.590 92.568 92.5810.35 %PASS 0.37 %PASSPASS92.243 0.38 %25,564 277 3 90.337 90.393 90.3330.45 %PASS 0.38 %PASSPASS89.992 0.38 %24,940 277 4 88.043 88.056 88.0920.36 %PASS 0.40 %PASSPASS87.744 0.34 %24,317 277 5 85.774 85.756 85.8140.31 %PASS 0.38 %PASSPASS85.492 0.33 %23,693 277 TWO-WINDING DRY-TYPE TRANSFORMER PAGE23210 - SE DRY TYPE TRANSFORMERDEVICE 08-547560DBID 23210, REVISED 10/27/2016(888) 778-2733 www.schneider-electric.us TECH NOTE(S): COMMENTS: DEFICIENCIES: INSULATION RESISTANCE IN: MEG-OHMS 20°C HUMIDITY WO-04790545 SE HVL/cc - VISI-VAC TEMPERATURE 83 °F PAGE END USER CUSTOMER Grapevine, TX 76051 GAYLORD TEXAN SITE LOCATION MVC-ADESIGNATION SUBSTATION Main DATE END USER ASSET/ID 8/22/2017 71 JOB # % DBID MVC-A 08-547660 DEVICE 06070 - SE MV HVLcc / Visi-Vac TESTED BY EQUIPMENT USEDJames Jillson Hi-pot N/A N/A N/A MATCHES DWG OR SPEC GROUND CONNECTION NT N/A N/A N/A COUNTER READING AF/AL ARCING CONTACTS HEATER CIRCUIT MAIN CONTACTS CUBICLE CLEAN/LUBE DESCRIPTION CLEAN/LUBECONDITION New New N/A N/A N/A CONTROL CIRCUIT FUSE HOLDERS CONDITIONDESCRIPTION CLEAN/LUBE N/AN/A DESCRIPTION N/A N/A N/AOPERATING MECHANISM N/A PHASE BARRIERS N/A N/A N/AAUXILIARY DEVICES ARC CHUTES N/A N/A N/AINTERLOCKS Acceptable N/AINS. LINKAGES / BRACES OVERALL CONDITION New CONDITION Acceptable Acceptable Acceptable Acceptable N/A SWITCH NAMEPLATE INSPECTION CONTROL WIRING 06070, REVISED 4/8/2015(888) 778-2733 www.schneider-electric.us @500V N/A MANUFACTURER RATED CURRENT INT. RATING N/A 17-37637568-138 25 kv 4/2017 SN / SO NO. RATED VOLTAGE CATALOG NO. MAX. VOLTAGE 25.8 kv BIL RATING TYPE / STYLE HVL / cc 125 N/A N/A ADDITIONAL INFO PICKUP VOLTS PICKUP VOLTS ADDITIONAL INFO VOLT RANGE N/AVOLT RANGE PICKUP VOLTS VOLT RANGE ADDITIONAL INFO DROP-OUT VOLTS CHARGING MOTOR INFORMATION N/A N/A N/A N/A CLOSE COIL INFORMATION N/A N/A N/A N/A N/A N/A N/A VOLTSVOLTS PICKUP VOLTS VOLTS TRIP COIL INFORMATION VOLTS ADDITIONAL INFO VOLT RANGE N/A N/A N/A N/A N/A OPTIONAL INFORMATION 18 1918 POLE 1 POLE 2 POLE 3 CONTACT RESISTANCE at CONTACT MEASUREMENTS TEST RESULTS 10 A (micro-ohms) MANUF. DATE 600 N/A FUSE AMPSN/AFUSE MFG.N/A FUSE CAT. NO.N/A D.C. A.C.27 VACUUM INTEGRITY (as per Manufacturer) POLE 2 PASS PASS PASS POLE 1 TEST KV POLE 3 N/A N/AVENTILLATION / FILTERS N/A GROUNDING SWITCH LIVE LINE INDICATORS Acceptable N/A N/ABLOWN FUSE INDICATOR N/A N/A Acceptable N/A N/A N/A MV CABLES @1000VMEG-OHMS 20°C 203.0 298.0 151.0 221.6 TEST 1 TEST 3 1.4678TEMPERATURE CORRECTION FACTOR TO 20°C, TCF TEST 2 INSULATION RESISTANCE IN:CLOSED: POLE-POLE 199.6136.0 20°C ACTUAL PH A ACTUALACTUAL A - B A-GND CLOSED: POLE-GROUND OPEN: LINE-LOAD 20°C PH B PH C B-GND C-GND B - C C - A 122.0 140.0 144.0 167.0 179.0 190.0211.4 179.1 278.9 205.5 245.1 262.7 Schneider Electric RANGE TECH NOTE(S): COMMENTS: DEFICIENCIES: INSULATION RESISTANCE IN: MEG-OHMS 20°C HUMIDITY WO-04790545 SE HVL/cc - VISI-VAC TEMPERATURE 83 °F PAGE END USER CUSTOMER Grapevine, TX 76051 GAYLORD TEXAN SITE LOCATION MVC-BDESIGNATION SUBSTATION Main DATE END USER ASSET/ID 8/22/2017 71 JOB # % DBID MVC-B 08-547670 DEVICE 06070 - SE MV HVLcc / Visi-Vac TESTED BY EQUIPMENT USEDJames Jillson Hi-pot N/A N/A N/A MATCHES DWG OR SPEC GROUND CONNECTION NT N/A N/A N/A COUNTER READING AF/AL ARCING CONTACTS HEATER CIRCUIT MAIN CONTACTS CUBICLE CLEAN/LUBE DESCRIPTION CLEAN/LUBECONDITION New New N/A N/A N/A CONTROL CIRCUIT FUSE HOLDERS CONDITIONDESCRIPTION CLEAN/LUBE N/AN/A DESCRIPTION N/A N/A N/AOPERATING MECHANISM N/A PHASE BARRIERS N/A N/A N/AAUXILIARY DEVICES ARC CHUTES N/A N/A N/AINTERLOCKS Acceptable N/AINS. LINKAGES / BRACES OVERALL CONDITION New CONDITION Acceptable Acceptable Acceptable Acceptable N/A SWITCH NAMEPLATE INSPECTION CONTROL WIRING 06070, REVISED 4/8/2015(888) 778-2733 www.schneider-electric.us @500V N/A MANUFACTURER RATED CURRENT INT. RATING N/A 17-37637568-138 25 kv 4/2017 SN / SO NO. RATED VOLTAGE CATALOG NO. MAX. VOLTAGE 25.8 kv BIL RATING TYPE / STYLE HVL / cc 125 N/A N/A ADDITIONAL INFO PICKUP VOLTS PICKUP VOLTS ADDITIONAL INFO VOLT RANGE N/AVOLT RANGE PICKUP VOLTS VOLT RANGE ADDITIONAL INFO DROP-OUT VOLTS CHARGING MOTOR INFORMATION N/A N/A N/A N/A CLOSE COIL INFORMATION N/A N/A N/A N/A N/A N/A N/A VOLTSVOLTS PICKUP VOLTS VOLTS TRIP COIL INFORMATION VOLTS ADDITIONAL INFO VOLT RANGE N/A N/A N/A N/A N/A OPTIONAL INFORMATION 19 1920 POLE 1 POLE 2 POLE 3 CONTACT RESISTANCE at CONTACT MEASUREMENTS TEST RESULTS 10 A (micro-ohms) MANUF. DATE 600 N/A FUSE AMPSN/AFUSE MFG.N/A FUSE CAT. NO.N/A D.C. A.C.27 VACUUM INTEGRITY (as per Manufacturer) POLE 2 PASS PASS PASS POLE 1 TEST KV POLE 3 New N/AVENTILLATION / FILTERS N/A GROUNDING SWITCH LIVE LINE INDICATORS Acceptable BLOWN FUSE INDICATOR N/A Acceptable N/A N/AMV CABLES @1000VMEG-OHMS 20°C 192.0 281.8 136.0 199.6 TEST 1 TEST 3 1.4678TEMPERATURE CORRECTION FACTOR TO 20°C, TCF TEST 2 INSULATION RESISTANCE IN:CLOSED: POLE-POLE 179.1122.0 20°C ACTUAL PH A ACTUALACTUAL A - B A-GND CLOSED: POLE-GROUND OPEN: LINE-LOAD 20°C PH B PH C B-GND C-GND B - C C - A 145.0 134.0 149.0 159.0 188.0 203.0218.7 212.8 298.0 196.7 233.4 275.9 Schneider Electric RANGE TECH NOTE(S): COMMENTS: DEFICIENCIES: HUMIDITY WO-04790545 TWO-WINDING DRY-TYPE TRANSFORMER TEMPERATURE 96 °F PAGE END USER CUSTOMER Grapevine, TX 76051 GAYLORD TEXAN SITE LOCATION MVC-B TransformerDESIGNATION SUBSTATION Main DATE END USER ASSET/ID 8/22/2017 75 JOB # % DBID MCV-B Transformer 08-547570 DEVICE 23210 - SE DRY TYPE TRANSFORMER TESTED BY EQUIPMENT USEDJames Jillson TTR, Megger Acceptable CONDITIONDESCRIPTION CLEAN/LUBEDESCRIPTION N/A N/A N/A N/A N/A Acceptable N/A FANS N/AAcceptable Acceptable N/A N/A N/A N/A N/AVENTILATION / FILTERS N/A PAINT New INDOOR N/ANew N/A MATCHES DWG OR SPEC WEATHER N/A ENVIRONMENT Acceptable N/A GAUGES SUPPORT INSULATORS N/AN/A N/A WINDINGS Acceptable N/A CABINET HEATERS AUXILIARY DEVICES N/AN/A PRIMARY CONNECTIONS TANK / FRAME GROUND NEUTRAL GROUND DESCRIPTION CONDITION SEC. CONNECTIONS Acceptable N/A N/A N/A N/A N/A ARRESTERS CORE GROUND ALARMS / ANNUNCIATOR CONTROLS BUSHINGS CLEAN/LUBE CLEAN/LUBECONDITION TEMPERATURE GAUGES WERE RESETunavailable°CMAXIMUM WINDING TEMPERATURE (1)°CunavailableWINDING TEMPERATURE (1) GAUGES N/A CONTROLLED 23210, REVISED 10/27/2016(888) 778-2733 www.schneider-electric.us / / 1 30 NAMEPLATE DATA RATED CURRENT RATED CURRENT AMPERES AMPERES/ 23,693 3 4 5 kV PRI. PRIMARY VOLTAGE SECONDARY VOLTAGE 277 WYE 26,187 TAP POSITION/CONNECTION 25,564 24,317 25 CLASS 110 24,940 PHASE 337637568-136-01-1SERIAL NO. kVA/ / THERMAL RATINGS DELTA kV SEC. IMPEDANCE 17200 30 % YEAR OF MANUF.TX05061001 2017 MANUFACTURER SPECIFICATION NO.MANUF. LOCATION TYPE AA K FACTOR N/A °CTEMPERATURE RISE Bland, Va 1505.88 B.I.L. RATINGWINDING MATERIAL Cu LB DELTA480 TAP VOLTAGES / WINDING POLARITY SUBTRACTIVE WYE / 1 24,940 2 TOTAL WEIGHT Dry Schneider Electric RANGE INSPECTION INSULATION RESISTANCE TEST TESTED PRIMARY TO SECONDARY AND GROUND SECONDARY TO PRIMARY AND GROUND VOLTAGE (VOLTS DC) (MEGOHMS) WINDINGS TEST RESISTANCE PRIMARY AND SECONDARY TO GROUND 1.0 MINUTE0.5 MINUTE 0.5 MIN. 20C 1.0 MIN. 20C DIELECTRIC ABSORPTION RATIO TEMPERATURE CORRECTION FACTOR TO 20°C, TCF 2.06 5,000 1,000 5,000 119.00 245.14 134.00 276.04 319.30155.00284.28138.00 142.00 292.52 160.00 329.60 1.13 1.12 1.13 CALCULATED PASS/FAIL CALCULATED PASS/FAIL TO % DEVIATIONMEASURED TO % DEVIATIONMEASURED TO % DEVIATIONMEASURED TRANSFORMER TURNS RATIO TESTS CALCULATED PASS/FAIL CALC. RATIO SECONDARY VOLTAGE ENTER PRIMARY VOLTAGE X1 - X0 X3 - X1 H1 - H3 H2 - H1 H3 - H2 X0 - X1 TAP TO TEST 1 94.247 94.286 94.2900.22 %PASS 0.21 %PASSPASS94.491 0.26 %26,187 277 2 92.490 92.510 92.5030.29 %PASS 0.28 %PASSPASS92.243 0.27 %25,564 277 3 90.337 90.393 90.3330.45 %PASS 0.38 %PASSPASS89.992 0.38 %24,940 277 4 87.996 87.990 88.0230.28 %PASS 0.32 %PASSPASS87.744 0.29 %24,317 277 5 85.821 85.809 85.7900.37 %PASS 0.35 %PASSPASS85.492 0.38 %23,693 277 TWO-WINDING DRY-TYPE TRANSFORMER PAGE23210 - SE DRY TYPE TRANSFORMERDEVICE 08-547570DBID 23210, REVISED 10/27/2016(888) 778-2733 www.schneider-electric.us TECH NOTE(S): COMMENTS: DEFICIENCIES: