HomeMy WebLinkAboutCA2018-866 August 2018 A Future With A Past Kevin Karlin Structured Foundation Repairs, Inc 629 West College Street Grapevine, Texas 76051 817 789-0946 RE: HISTORIC PRESERVATION COMMISSION CERTIFICATE OF APPROPRIATENESS #CA18-86 WESTCHESTER PLACE OFFICE CONDO STEVEN COOK, OWNER 629 WEST COLLEGE STREET GRAPEVINE, TEXAS 76051 This letter confirms on August 6, 2018 the Historic Preservation Commission staff approved with conditions #CA18-86 for the property addressed 629 West College Street, legally described as Lot D, Westchester Place Office Condo, City of Grapevine Texas. The following was approved on this Certificate of Appropriateness: 1. Foundation repair to existing building, to include installation of 14 concrete pressed pilings to support the foundation; as per attached plans with the conditions that a permit be obtained from the Building Department. An approved Certificate of Appropriateness is not an approved building permit; a building permit is / is not required. Contact the City of Grapevine's Building Department at 817.410.3165 for fees and information regarding permits. Thank you, olyn J�L, David Klempin Historic Preservation Officer cc. Property Owner CA File THE CITY OF GRAPEVINE HISTORIC PRESERVATION • 636 South Main Street • Grapevine, Texas 76051 Phone 817/410-3556 - Fax 817/410-3038 Date 8/3/2018 CERTIFICATE OF APPROPRIATENESS APPLICATION Property Owner Name, Address 8r Phone Number Steven Cook (Investor) 627 W College Street, Grapevine, TX. 76051 Phone: 817-789-0946 Mobile: Email: Property Address include any suite number 629 W College Street Grapevine, TX. 76051 446 3 6A Applicant Name, Address & Phone Number Kevin Karlin/ Structured Foundation Repairs Inc. 13301 Trinity Blvd. #133 Euless, TX. 76040 Phone: 972-484-1200 Mobile Emall: Le al Description Block Lot Subdivision Tenant Name/Occupancy/Use tj i C5 S Residence (� i' Bui -J)y 4 Request/Description of Work to Be Done Install 14 concrete pressed pilings to support the foundation. Drawings/Sketches Attached V Yes o No Material Sam les Attached lease list Photo ra hs Attached o Current o Historic l hereby certify that this information is correct to the best of my knowledge and that the said work will be done in conformance with all submissions herein set forth, and in compliance with the City of Grapevine's Historic Overlay District Ordinances and Building Codes. APPROVAL OF A CERTIFICATE OF APPROPRIATENESS DOES NOT CONSTITUTE APPROVAL OF OTHER REQUIRED BUILD NG PE�. Signed x Print Name7 Kevin Karlin OvVner or Contractor Office Use o Approved- Approved with Conditions: Staff ►, HPC 760'm > t (2-e- 0 t (L o I Denied Chair— Historic Preservation Commission Date Building Official THIS IS NOT A BUILDING PERMIT. V A SEPARATE BUILDING PERMIT MUST BE FILED AND APPROVED BY THE BUILDING DEPARTMENT BEFORE STARTING WORK. DELIVER TO: HISTORIC PRESERVATION DEPARTMENT OFFICE 817-410-3556 636 SOUTH MAIN STREET, GRAPEVINE, TEXAS 1902 Forest Glen LN Weatherford, Texas 76087 817-948-4004 Info (c-Nortierl la com Initial Report for Foundation Assessment Date: July 26, 2018 Attention: Structured Foundation Repair (The Client) Subject: Foundation Review 629 W College St., Grapevine, Texas 4NNOOTIEO ENGINEERING CON51JLiANiS LlC Authorization and Scope: Nortier Engineering Consultants, LLC (NEC) has been retained by the Client to perform a review of the slab on grade foundation system of the 2 story residential building with brick veneer located at the subject address referenced above. This report provides guidance as to whether or not the existing foundation system is in need of repair. The report also proposes a recommended plan if repairs are needed. Conclusions/Specific Recommendation: NEC performed a visual examination of the foundation for the subject property on 7/26/2018. NEC also performed a floor survey using a Zip -level Pro -2000 series, collecting relative floor elevations, to aid in surface topography mapping of the floor(s). Elevations shown are adjusted for the type of flooring encountered to reflect a consistent measuring plane. The map of the existing floor elevations can be seen in the figure attached to this report. Based on review of the foundation, and reasonable professional engineering opinion, we've determined that settlement of the foundation has occurred and should be repaired. Although complete levelness cannot be guaranteed, or may not be attainable, the proposed plan should improve the performance of the foundation. It is recommended that fourteen (14) piers be installed as indicated on the figure(s) attached to this report. Locations of internal piers [if needed] are intended to be approximate. The Contractor should locate the beams and place internal piers accordingly. Furthermore, the proposed foundation repairs shall meet or exceed the 2015 International Residential Code (IRC) and any local applicable amendments to the IRC. This report is solely based on information gathered during our site visit on 7/26/2018, and does not take into consideration any changes in condition of the foundation or soils after the date which the information was gathered. 1902 Forest Glen LN Weatherford, Texas 76087 817-948-4004 Info(a-Mortierllc. corn WIER ENGINEERING C0N511LiANiS LLC General Recommendations: It is recommended that the soil be graded such that the bottom portion of the foundation is below grade, as per the governing code and a watering system be utilized around the perimeter of the house. Fluctuations in moisture content of the soils near the foundation of the house can cause differential settlement. If the moisture content is kept consistent, the potential for differential movement is mitigated. It is also recommended that the plumbing systems be checked after any repairs are made to the foundation system. Vertical movement of the foundation system can impose stresses on the plumbing infrastructure and cause leaks. Furthermore, grading around the perimeter of the building should be maintained as sloping away from the foundation at a minimum of 6 inches fall within the first 10 feet from the foundation. Such grading configuration should prevent localized water accumulating around areas of the foundation. Saturated soils decline in bearing capacity and can result in differential settlement of the foundation. Limitations: This report is intended for information purposes only, and the sole use of the client and/or homeowner. The scope of this report is limited to the items related to the foundation system only, and it is understood that detection of all existing or potential defects is not feasible for this type of evaluation. The intent of this report does not include judgment on any of the superstructure, detached buildings, retaining or privacy walls, concrete reinforcement, and/or site drainage. In addition, the scope of this report excludes material and soil sampling/testing, procedures and as such were not performed. The report is not to be used by others for any purpose without our written consent. Compliance with any code or specification other than as expressly noted in this report is specifically excluded. It is the responsibility of any Contractor to abide by any other applicable codes or specifications. No warranty for any repairs, future foundation performance, structure, vegetation, or soils at the subject property are offered by this report, nor does this report imply any liability to NEC, nor Daneel Nortier, PE for any work to be performed as a result of this report. It is understood that soils in this area experience movement due to moisture fluctuations. Such soil movement could cause the foundation to move after the recommended repairs have been made. Any provided floor elevation data and recommended actions are based on soil conditions as they exist at the time of the evaluation. NEC does not warrant or imply that other problems may not occur in the future. No warranty, expressed or implied, is made or intended and the limit of liability shall be limited to the fee paid for this report at the time of evaluation. Report Prepared by, o F . 7- +et I Nortier Engineering Consultants LLC * • s*�� Texas Engineering Firm (F-16800) .•. ........ �• of A EEL ORTIERgo j 7/26/2018 o 11.• 15 ... •.' Daneel Nortier, P.E. • • �� .. Professional Engineer (TX #113157) s� ,s 9 Photograph Label SP Separation Stress crack Cleanout New pier 0 10 2( 1 I I All measurements shown in tenth of an inch \\\ OFF O�P�E •TF�IsI •, 9 .• A EELORTIER ......... .. .. i 1 7/26/18 629 W. College Street By: DN Grapevine, Texas CERTIFICATE OF APPROPRIATENESS CITY OF GRAPEVINE RELEA PURSU4bTCA DATEoBY TM OF DEVELOPMENT SERVICES CONTACT BUILDING INSPECTIONS FOR PERMIT INFORMATION SP 3P WVCC11ER ENGINEERING CRNSiLiAN1S Beam =I I H I 1=11= NOTES: —i H I I =1 =1 I_= III= 1) Piles shall be driven to refusal 2) Contractor shall install double piers for shallow foundations (6ft or less), or where indicated Steel Shims 3) Where double piers are used, concrete blocks and steel shims may be use in -leu of top cap Concrete Top Cap (Double Pier - See Note 3) 6" Diameter by 12" Long yi Precast Concrete Cylinder W/ Reinforcing Steel �S�PSE OF•T�+�S�l .... A EEL ORTIER j ...................... i 0,, 11 15 6/20/2016 Precast Concrete Pier Detail Diagram �C Firm # 16800 Not to scale HURTER ENRINEERIN6 CUNSULTANIS CERTIFICATE OF APPROPRIATENESS CITY OF GRAPEVINE RELEAS PURSUANT TO A 61, DATE S� BY � " D PA MENT OF DEVELOPMENT SERVICES CONTACT BUILDING INSPECTIONS FOR PERMIT INFORMATION