Loading...
HomeMy WebLinkAboutTerracon - 5/24/2018CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 95181011.0262 Service Date: 05/24/18 2501 E Loop 820 N Report Date: 06/05/18 Fort Worth, TX 76118-6978 Task: 817-268-8600 Ree No: F-3272 Client Project Coury Hospitality Attn: Mark Brooks 7134 S Yale, Ste 400 Tulsa, OK 74136 Grapevine Main Phase 1 815 South Main Street Grapevine, TX 76051 Project Number: 95181011 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 6206 Supplier: Argos Batch Time: 1000 Plant: Truck No.: 4046 Ticket No.: 11026581 Field Test Data Test Result Slump (in): 41/2 Air Content (%): 2.1 Concrete Temp. (F): 91 Ambient Temp. (F): 94 Plastic Unit Wt. (pcf): 149.6 Yield (Cu. Yds.): 45.0 Laboratory Test Data Set Specimen Avg Diam. No. ID (in) 1 A 4.00 1 B 4.00 1 C 4.00 1 D 4.00 1 E 47,600 Initial Cure: Outside 06/21/18 Comments: Specification 3-5 0-3 Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Placement Method: Water Added Before (gal): Water Added After (gal): Sample Location: Placement Location: Age at Maximum Area Date Date Test Load (sq in) Received Tested (days) (lbs) 12.57 05/31/18 7 47,600 12.57 06/21/18 28 12.57 06/21/18 28 12.57 06/21/18 28 Hold Final Cure: Moist Room 05/24/18 Sample Time: 1030 Daniel Blocker clear 30 Batch Size (cy): 10 PUMP SOG @ GL (D/9) Hotel SOG @ GL(C.6-G.6/7.5-10.5) Compressive Strength Fracture Tested (psi) Type By 3,790 4 Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Daniel Blocker Reported To: Contractor: Report Distribution: See attached distribution list. Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cx000t, 11-16-12, xev.6 Page 1 of 2 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 95181011.0262 Service Date: 05/24/18 2501 E Loop 820 N Report Date: 06/05/18 Fort Worth, TX 76118-6978 Task: 817-268-8600 Ree No: F-3272 Client Project Coury Hospitality Attn: Mark Brooks 7134 S Yale, Ste 400 Tulsa, OK 74136 Grapevine Main Phase 1 815 South Main Street Grapevine, TX 76051 Project Number: 95181011 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 6206 Supplier: Argos Batch Time: 1230 Truck No.: 4027 Field Test Data Test Slump (in): Air Content (%): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Laboratory Test Data Plant: Ticket No.: 12328 Set Specimen Avg Diam. Result No. ID (in) 2 A 4.00 2 B 4.00 2 C 4.00 2 D 4.00 2 E 42,160 Initial Cure: Outside 06/21/18 Comments: 5 1.9 92 92 149.2 44.9 Specification 3-5 0-3 Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Placement Method: Water Added Before (gal): Water Added After (gal): Sample Location: Placement Location: Age at Maximum Area Date Date Test Load (sq in) Received Tested (days) (lbs) 12.57 05/31/18 7 42,160 12.57 06/21/18 28 12.57 06/21/18 28 12.57 06/21/18 28 Hold Final Cure: Moist Room 05/24/18 Sample Time: 1300 Daniel Blocker clear 120 Batch Size (cy): 10 PUMP SOG @ (E.2/13.7) Hotel SOG @ GL(C.6-G.6/7.5-10.5) Compressive Strength Fracture Tested (psi) Type By 3,350 5 Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Daniel Blocker Reported To: Contractor: Report Distribution: See attached distribution list. Reviewed By: Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Cx000t, 11-16-12, xev.6 Page 2 of 2 Distribution Page Report Number: 95181011.0262 Service Date: 05/24/18 Report Date: 06/05/18 Task: Distribution List (1) Coury Hospitality, Mark Brooks (1) AECC Inc, Lee Ledet (1) ArchiTexas, Michael Karnowski (1) City of Grapevine TX, Curtis A Bergthold (1) Construction Management Group of Fair Oaks CA, Blake Cearley (1) JQ Engineering, Mike Oler (1) Manhattan Construction Co, Ben Jensen (1) Manhattan Construction Co, Brad Scheckelhoff (1) Manhattan Construction Co, Chase Pritchard (1) Manhattan Construction Co, Daniel Rideau (1) Manhattan Construction Co, David Saiter (1) Manhattan Construction Co, Frederick Moore (1) Manhattan Construction Co, Robert Montgomery Irerracon 2501 E Loop 820 N Fort Worth, TX 76118-6978 817-268-8600