HomeMy WebLinkAboutTerracon - 5/24/2018CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon
Report Number: 95181011.0262
Service Date: 05/24/18 2501 E Loop 820 N
Report Date: 06/05/18 Fort Worth, TX 76118-6978
Task: 817-268-8600 Ree No: F-3272
Client Project
Coury Hospitality
Attn: Mark Brooks
7134 S Yale, Ste 400
Tulsa, OK 74136
Grapevine Main Phase 1
815 South Main Street
Grapevine, TX 76051
Project Number: 95181011
Material Information Sample Information
Specified Strength: 4,000 psi @ 28 days
Mix ID: 6206
Supplier: Argos
Batch Time: 1000 Plant:
Truck No.: 4046 Ticket No.: 11026581
Field Test Data
Test
Result
Slump (in):
41/2
Air Content (%):
2.1
Concrete Temp. (F):
91
Ambient Temp. (F):
94
Plastic Unit Wt. (pcf):
149.6
Yield (Cu. Yds.):
45.0
Laboratory Test Data
Set Specimen Avg Diam.
No. ID
(in)
1 A
4.00
1 B
4.00
1 C
4.00
1 D
4.00
1 E
47,600
Initial Cure: Outside
06/21/18
Comments:
Specification
3-5
0-3
Sample Date:
Sampled By:
Weather Conditions:
Accumulative Yards:
Placement Method:
Water Added Before (gal):
Water Added After (gal):
Sample Location:
Placement Location:
Age at Maximum
Area
Date Date
Test
Load
(sq in)
Received Tested
(days)
(lbs)
12.57
05/31/18
7
47,600
12.57
06/21/18
28
12.57
06/21/18
28
12.57
06/21/18
28
Hold
Final Cure: Moist Room
05/24/18 Sample Time: 1030
Daniel Blocker
clear
30 Batch Size (cy): 10
PUMP
SOG @ GL (D/9)
Hotel SOG @ GL(C.6-G.6/7.5-10.5)
Compressive
Strength Fracture Tested
(psi) Type By
3,790 4
Samples Made By: Terracon
Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength
samples.
Terracon Rep.: Daniel Blocker
Reported To:
Contractor:
Report Distribution:
See attached distribution list.
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
cx000t, 11-16-12, xev.6 Page 1 of 2
CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon
Report Number: 95181011.0262
Service Date: 05/24/18 2501 E Loop 820 N
Report Date: 06/05/18 Fort Worth, TX 76118-6978
Task: 817-268-8600 Ree No: F-3272
Client Project
Coury Hospitality
Attn: Mark Brooks
7134 S Yale, Ste 400
Tulsa, OK 74136
Grapevine Main Phase 1
815 South Main Street
Grapevine, TX 76051
Project Number: 95181011
Material Information Sample Information
Specified Strength: 4,000 psi @ 28 days
Mix ID:
6206
Supplier:
Argos
Batch Time:
1230
Truck No.:
4027
Field Test Data
Test
Slump (in):
Air Content (%):
Concrete Temp. (F):
Ambient Temp. (F):
Plastic Unit Wt. (pcf):
Yield (Cu. Yds.):
Laboratory Test Data
Plant:
Ticket No.: 12328
Set Specimen Avg Diam.
Result
No. ID
(in)
2 A
4.00
2 B
4.00
2 C
4.00
2 D
4.00
2 E
42,160
Initial Cure: Outside
06/21/18
Comments:
5
1.9
92
92
149.2
44.9
Specification
3-5
0-3
Sample Date:
Sampled By:
Weather Conditions:
Accumulative Yards:
Placement Method:
Water Added Before (gal):
Water Added After (gal):
Sample Location:
Placement Location:
Age at Maximum
Area
Date Date
Test
Load
(sq in)
Received Tested
(days)
(lbs)
12.57
05/31/18
7
42,160
12.57
06/21/18
28
12.57
06/21/18
28
12.57
06/21/18
28
Hold
Final Cure: Moist Room
05/24/18 Sample Time: 1300
Daniel Blocker
clear
120 Batch Size (cy): 10
PUMP
SOG @ (E.2/13.7)
Hotel SOG @ GL(C.6-G.6/7.5-10.5)
Compressive
Strength Fracture Tested
(psi) Type By
3,350 5
Samples Made By: Terracon
Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength
samples.
Terracon Rep.: Daniel Blocker
Reported To:
Contractor:
Report Distribution:
See attached distribution list.
Reviewed By:
Senior Project Manager
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
Cx000t, 11-16-12, xev.6 Page 2 of 2
Distribution Page
Report Number: 95181011.0262
Service Date: 05/24/18
Report Date: 06/05/18
Task:
Distribution List
(1) Coury Hospitality, Mark Brooks
(1) AECC Inc, Lee Ledet
(1) ArchiTexas, Michael Karnowski
(1) City of Grapevine TX, Curtis A Bergthold
(1) Construction Management Group of Fair Oaks CA, Blake Cearley
(1) JQ Engineering, Mike Oler
(1) Manhattan Construction Co, Ben Jensen
(1) Manhattan Construction Co, Brad Scheckelhoff
(1) Manhattan Construction Co, Chase Pritchard
(1) Manhattan Construction Co, Daniel Rideau
(1) Manhattan Construction Co, David Saiter
(1) Manhattan Construction Co, Frederick Moore
(1) Manhattan Construction Co, Robert Montgomery
Irerracon
2501 E Loop 820 N
Fort Worth, TX 76118-6978
817-268-8600