Loading...
HomeMy WebLinkAboutTerracon - 7/30/2018CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 95181011.0389 Service Date: 07/30/18 2501 E Loop 820 N Report Date: 08/08/18 Fort Worth, TX 76118-6978 Task: 817-268-8600 Ree No: F-3272 Client Project Coury Hospitality Attn: Mark Brooks 7134 S Yale, Ste 400 Tulsa, OK 74136 Grapevine Main Phase 1 815 South Main Street Grapevine, TX 76051 Project Number: 95181011 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1654 Supplier: Argos Batch Time: 1341 Plant: 123 Truck No.: 5106 Ticket No.: 12331266 Field Test Data Test Slump (in): Air Content (%): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Result Specification 5 3-5 1.0 0-3 91 50-95 84 Bucket & lift 150.8 7 Laboratory Test Data Set Specimen Avg Diam. No. ID (in) 1 A 6.00 1 B 6.00 1 C 6.00 1 D Bucket & lift 1 E 7 Initial Cure: Outside 0 Comments: Samples Made By: Terracon Sample Date: 07/30/18 Sample Time: 1420 Sampled By: Andrew Cloeter Weather Conditions: Clear Accumulative Yards: 5 Batch Size (cy): 5 Placement Method: Bucket & lift Water Added Before (gal): 7 Water Added After (gal): 0 Sample Location: North Grade Beam, East Side Placement Location: 10' Isolated Grade Beams on North 28 and South Side of Hotel, see attached Age at Maximum Area Date Date Test Load (sq in) Received Tested (days) (lbs) 28.27 07/31/18 08/06/18 7 91,300 28.27 07/31/18 08/27/18 28 28.27 07/31/18 08/27/18 28 07/31/18 Hold 07/31/18 Hold Final Cure: Moist Room Compressive Strength Fracture Tested (psi) Type By 3,230 4 Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Andrew Cloeter Reported To: David with Manhattan Contractor: Manhattan Report Distribution: See attached distribution list. Reviewed By: Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Cx000t, 11-16-12, xev.6 Page 1 of 1 11 ;A, r (I P 0 Distribution Page Report Number: 95181011.0389 Service Date: 07/30/18 Report Date: 08/08/18 Task: Distribution List (1) Coury Hospitality, Mark Brooks (1) AECC Inc, Lee Ledet (1) ArchiTexas, Michael Karnowski (1) City of Grapevine TX, Curtis A Bergthold (1) Construction Management Group of Fair Oaks CA, Blake Cearley (1) JQ Engineering, Mike Oler (1) Manhattan Construction Co, Ben Jensen (1) Manhattan Construction Co, Brad Scheckelhoff (1) Manhattan Construction Co, Chase Pritchard (1) Manhattan Construction Co, Daniel Rideau (1) Manhattan Construction Co, David Saiter (1) Manhattan Construction Co, Frederick Moore (1) Manhattan Construction Co, Robert Montgomery Irerracon 2501 E Loop 820 N Fort Worth, TX 76118-6978 817-268-8600 FIELD DENSITY TEST REPORT Irerracon Report Number: 95181011.0387 Service Date: 07/30/18 2501 E Loop 820 N Report Date: 08/09/18 Fort Worth, TX 76118-6978 Task: 817-268-8600 Ree No: F-3272 Client Project Coury Hospitality Attn: Mark Brooks 7134 S Yale, Ste 400 Tulsa, OK 74136 Grapevine Main Phase 1 815 South Main Street Grapevine, TX 76051 Project Number: 95181011 Material Information Lab Test Data Project Requirements Mat. Proctor No. Ref. No. 1 95181011.0235 Field Test Data Classification and Description Brown Sandy Clay with Trace of LSF Test No. Test Location Hotel Ext. GB 109 G.6/12 (Elevations are below top of Gradebeam) 110 G.6/13 Laboratory Test Method ASTM D698 Optimum Water Max. Lab Water Content Density Content Compaction (%) (pcf) (%) (%) 15.5 113.3 Min/+3 >93 Probe Wet Water Water Dry Percent Lift / Mat. Depth Density Content Content Density Compaction Elev. No. (in) (pcf) (pcf) (%) (pcf) (%) 5.5' BGB 1 6 122.6 14.7 13.6 107.9 95 6.5 BGB 1 6 121.2 14.1 13.2 107.1 95 Datum: S/N: Make: Model: Last Cal. Date: Comments: An asterisk (*) appears next to the test results which do not meet the project requirements as noted above. Services: Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition (ASTM D-6938). Terracon Rep.: Adam Wood Reported To: David with Manhattan Contractor: Manhattan Report Distribution: See attached distribution list. Reviewed By: __Lto Tul Senior Project Manager Test Methods: ASTM D6938 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cRoo07, 11-16-12, Rev.7 Page 1 of 1 Distribution Page Report Number: 95181011.0387 Service Date: 07/30/18 Report Date: 08/09/18 Task: Distribution List (1) Coury Hospitality, Mark Brooks (1) AECC Inc, Lee Ledet (1) ArchiTexas, Michael Karnowski (1) City of Grapevine TX, Curtis A Bergthold (1) Construction Management Group of Fair Oaks CA, Blake Cearley (1) JQ Engineering, Mike Oler (1) Manhattan Construction Co, Ben Jensen (1) Manhattan Construction Co, Brad Scheckelhoff (1) Manhattan Construction Co, Chase Pritchard (1) Manhattan Construction Co, Daniel Rideau (1) Manhattan Construction Co, David Saiter (1) Manhattan Construction Co, Frederick Moore (1) Manhattan Construction Co, Robert Montgomery Irerracon 2501 E Loop 820 N Fort Worth, TX 76118-6978 817-268-8600