HomeMy WebLinkAboutTerracon - 2/01/2018FIELD DENSITY TEST REPORT Irerracon
Report Number: 95181011.0016
Service Date: 02/01/18 2501 E Loop 820 N
Report Date: 02/07/18 Fort Worth, TX 76118-6978
Task: 817-268-8600 Ree No: F-3272
Client Project
Brooks Hospitality Consulting Corp
Attn: Mark Brooks
206 Oldenwood Ct
Colleyville, TX 76034
Grapevine Main Phase 1
815 South Main Street
Grapevine, TX 76051
Project Number: 95181011
Material Information Lab Test Data Project Requirements
Optimum
Datum: Moisture Condition. Serial No: Std. Cnt. M:670 Std. Cnt. D: 2075
Comments: Test and/or retest results on this report meet project requirements as noted above.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
cRoo07, 11-16-12, Rev.7 Page 1 of 2
Water
Max. Lab
Water
Mat.
Proctor
Laboratory
Content
Density
Content
Compaction
No.
Ref. No.
Classification and Description
Test Method
(%)
(pcf)
1
95181011.0004
Yellowish Brown Clayey Sand
ASTM D698
18.4
106.2
+4
94%+
Field
Test Data
Probe
Wet
Water
Water
Dry
Percent
Test
Lift /
Mat.
Depth
Density
Content
Content
Density
Compaction
No.
Test Location Elev.
No.
(in)
(pcf)
(pcf)
(%)
(pcf)
(%)
Parking Garage (P12.5 -P13/17-18)
1
P12.7/17.6
2
1
6
124.7
24.5
24.5
100.2
94
2
P12.8/17.3
2
1
6
124.6
24.7
24.7
99.9
94
3
P12.5/17.5
3
1
6
123.5
22.6
22.4
100.9
95
4
P12.7/17.3
3
1
6
123.1
22.9
22.9
100.2
94
5
P12.6/17.8
4
l
6
122.8
23.5
23.7
99.3
94
6
P12.8/17.4
4
1
6
123.4
22.6
22.4
100.8
95
7
P12.5/17.8
5
1
6
124.6
23.8
23.6
100.8
95
8
P12.8/17.5
5
1
6
122.5
23.0
23.1
99.5
94
9
P12.7/17.3
6
1
6
122.5
23.0
23.1
99.5
94
10
P12.8/17.8
6
1
6
123.4
23.0
22.9
100.4
95
11
P12.5/17.9
7
l
6
122.4
22.7
22.8
99.7
94
12
P12.8/17.3
7
1
6
123.5
23.7
23.7
99.8
94
13
P12.6/17.8
8
1
6
123.7
23.5
23.5
100.2
94
14
P12.9/17.2
8
1
6
125.4
23.7
23.3
101.7
96
(P12 -P13/15-17)
15
P12.5/16.7
1
1
6
123.5
23.9
24.0
99.6
94
16
P12.2/15.7
1
1
6
123.6
23.5
23.5
100.1
94
Datum: Moisture Condition. Serial No: Std. Cnt. M:670 Std. Cnt. D: 2075
Comments: Test and/or retest results on this report meet project requirements as noted above.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
cRoo07, 11-16-12, Rev.7 Page 1 of 2
FIELD DENSITY TEST REPORT Irerracon
Report Number: 95181011.0016
Service Date: 02/01/18 2501 E Loop 820 N
Report Date: 02/07/18 Fort Worth, TX 76118-6978
Task: 817-268-8600 Reg No: F-3272
Client Project
Brooks Hospitality Consulting Corp Grapevine Main Phase 1
Attn: Mark Brooks 815 South Main Street
206 Oldenwood Ct Grapevine, TX 76051
Colleyville, TX 76034
Project Number: 95181011
Services: Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition (ASTM D-6938).
Terracon Rep.: Daniel Moreno
Reported To:
Contractor:
Report Distribution:
(1) Brooks Hospitality Consulting Corp, Mark (1) Manhattan Construction Co, Ben Jensen Reviewed By:
Brooks Jo -. . T upa
(1) Manhattan Construction Co, Brad (1) Manhattan Construction Co, Chase Pritchard Senior Project Manager
Scheckelhoff
(1) Manhattan Construction Co, Daniel Rideau (1) Manhattan Construction Co, David Saiter
(1) Manhattan Construction Co, Frederick Moore (1) Manhattan Construction Co, Robert
Montgomery
Test Methods: ASTM D6938
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
CRoo07, 11-16-12, Rev.7 Page 2 of 2
CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon
Report Number: 95181011.0015
Service Date: 02/01/18 2501 E Loop 820 N
Report Date: 03/09/18 Revision 1 - 28 -day results Fort Worth, TX 76118-6978
Task: 817-268-8600 Ree No: F-3272
Client Project
Coury Hospitality
Attn: Mark Brooks
7134 S Yale, Ste 400
Tulsa, OK 74136
Grapevine Main Phase 1
815 South Main Street
Grapevine, TX 76051
Project Number: 95181011
Material Information Sample Information
Specified Strength: 4,000
psi @
28 days
Sample Date:
02/01/18
Sample Time:
1615
Sampled By:
Daniel Blocker
Mix ID: 9211
Weather Conditions:
Clear
Supplier: Argos
Accumulative Yards:
16
Batch Size (cy):
8
Batch Time: 1545
Plant:
104
Placement Method:
Bucket
Truck No.: 5094
Ticket No.:
10428505
Water Added Before (gal): 0
Water Added After (gal): 0
Field Test Data
Sample Location:
Pier 2072,
Grid Line P5/15.7
Test
Result
Specification
Placement Location:
Drilled Piers, see report
Slump (in):
7
6-8
95181011.0014
Air Content (%):
1.7
0-3
Concrete Temp. (F):
61
45-95
Ambient Temp. (F):
70
36-100
Plastic Unit Wt. (pcf):
148.4
Yield (Cu. Yds.):
44.7
Laboratory Test Data
Age at
Maximum
Compressive
Set Specimen Avg
Diam.
Area Date
Date Test
Load
Strength Fracture
No. ID
(in)
(sq in) Received
Tested (days)
(lbs)
(psi)
Type
1 A
4.00
12.57 02/02/18
02/08/18 7
50,690
4,030
4
1 B
4.00
12.57 02/02/18
03/01/18 28
74,160
5,900
4
1 C
4.00
12.57 02/02/18
03/01/18 28
69,790
5,550
4
1 D
4.00
12.57 02/02/18
03/01/18 28
75,500
6,010
4
Average (28 days)
5,820
1 E
02/02/18
Hold
Initial Cure: Outside
Final Cure: Moist Room
Comments: Average compressive strength of 28 day cylinders complies with the specified strength.
Samples Made By: Terracon
Services: Verify aggregate moisture contents and batch weight corrections, witness batching procedure, sample concrete, perform
plastic concrete tests and cast cylinders for laboratory strength testing.
Terracon Rep.: Daniel Blocker
Reported To:
Contractor: Manhattan
Report Distribution:
See attached distribution list.
Reviewed By:
Senior Project Manager
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
cx000t, 11-16-12, xev.6 Page 1 of 1
Distribution Page
Report Number: 95181011.0015
Service Date: 02/01/18
Report Date: 03/09/18 Revision 1 - 28 -day results
Task:
Distribution List
(1) Coury Hospitality, mark@brookshc.com
(1)AECC Inc, leel@aeccinc.com
(1) City of Grapevine TX, curtisb@grapevinetexas.gov
(1) Manhattan Construction Co, bjensen@manhattanconstruction.com
(1) Manhattan Construction Co, bscheckelhoff@manhattanconstruction.com
(1) Manhattan Construction Co, cpritchard@manhattanconstruction.com
(1) Manhattan Construction Co, drideau@manhattanconstruction.com
(1) Manhattan Construction Co, dsaiter@manhattanconstruction.com
(1) Manhattan Construction Co, frederick.moore@manhattanconstruction.com
(1) Manhattan Construction Co, rmontgomery2@manhattanconstruction.com
Irerracon
2501 E Loop 820 N
Fort Worth, TX 76118-6978
817-268-8600
CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon
Report Number: 95181011.0015
Service Date: 02/01/18 2501 E Loop 820 N
Report Date: 02/12/18 Fort Worth, TX 76118-6978
Task: 817-268-8600 Ree No: F-3272
Client Project
Coury Hospitality
Attn: Mark Brooks
7134 S Yale, Ste 400
Tulsa, OK 74136
Grapevine Main Phase 1
815 South Main Street
Grapevine, TX 76051
Project Number: 95181011
Material Information Sample Information
Specified Strength: 4,000 psi @ 28 days
Mix ID:
9211
Supplier:
Argos
Batch Time:
1545 Plant: 104
Truck No.:
5094 Ticket No.: 10428505
Field Test Data
Test
Result
Specification
Slump (in):
7
6-8
Air Content (%):
1.7
0-3
Concrete Temp. (F):
61
45-95
Ambient Temp. (F):
70
36-100
Plastic Unit Wt. (pcf):
148.4
4.00
Yield (Cu. Yds.):
44.7
Laboratory Test Data
Set
Specimen
Avg Diam.
No.
ID
(in)
1
A
4.00
1
B
4.00
1
C
4.00
1
D
4.00
1
E
Initial Cure: Outside
Final Cure: Moist
Comments:
Sample Date:
02/01/18 Sample Time: 1615
Sampled By:
Daniel Blocker
Weather Conditions:
Clear
Accumulative Yards:
16 Batch Size (cy): 8
Placement Method:
Bucket
Water Added Before (gal):
0
Water Added After (gal):
0
Sample Location:
Pier 2072, Grid Line P5/15.7
Placement Location:
Drilled Piers, see report
95181011.0014
Area
Date
Date
(sq in)
Received
Tested
12.57
02/02/18
02/08/18
12.57
02/02/18
03/01/18
12.57
02/02/18
03/01/18
12.57
02/02/18
03/01/18
02/02/18
Final Cure: Moist
Room
Age at Maximum
Test Load
(days) (lbs)
7 50,690
28
28
28
Hold
Compressive
Strength Fracture
(psi) Type
4,030 4
Samples Made By: Terracon
Services: Verify aggregate moisture contents and batch weight corrections, witness batching procedure, sample concrete, perform
plastic concrete tests and cast cylinders for laboratory strength testing.
Terracon Rep.: Daniel Blocker
Reported To:
Contractor: Manhattan
Report Distribution:
See attached distribution list.
Reviewed By:
Senior Project Manager
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
cx000t, 11-16-12, xev.6 Page 1 of 1
Distribution Page
Report Number: 95181011.0015
Service Date: 02/01/18
Report Date: 02/12/18
Task:
Distribution List
(1) Coury Hospitality, mark@brookshc.com
(1) Manhattan Construction Co, bjensen@manhattanconstruction.com
(1) Manhattan Construction Co, bscheckelhoff@manhattanconstruction.com
(1) Manhattan Construction Co, cpritchard@manhattancontruction.com
(1) Manhattan Construction Co, drideau@manhattanconstruction.com
(1) Manhattan Construction Co, dsaiter@manhattanconstruction.com
(1) Manhattan Construction Co, frederick.moore@manhattanconstruction.com
(1) Manhattan Construction Co, rmontgomery2@manhattanconstruction.com
Irerracon
2501 E Loop 820 N
Fort Worth, TX 76118-6978
817-268-8600
DRILLED PIER OBSERVATION REPORT
Report Number: 95181011.0014
Irerracon
Service Date: 02/01/18 2501 E Loop 820 N
Report Date: 02/09/18 Fort Worth, TX 76118-6978
817-268-8600 Reg No: F-3272
Client Project
Coury Hospitality Grapevine Main Phase 1
Attn: Mark Brooks 815 South Main Street
7134 S Yale, Ste 400 Grapevine, TX 76051
Tulsa, OK 74136
Proiect Number: 95181011
On this date, a Terracon technician arrived at the above referenced jobsite as scheduled for Drilled Pier Observation. See attached sheet
for recorded data.
NOTE: Elevation data provided by others or taken from plans.
Services: Drilled Pier Observation
Terracon Rep.: Daniel Blocker
Reported To:
Contractor: Manhattan
Report Distribution:
See attached distribution list.
Reviewed By:
�,Tuipa
Senior Project Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to
the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
sC0001, 10-16-13, Rev.10 Page 1 of 1
DRILLED PIER OBSERVATION
Report Number: 95181011.0014
Service Date: February 1, 2018
Client: Brooks Hospitality Consulting Corp
Attn: Mark Brooks
206 Oldenwood Ct
Colleyville, TX 76034
Driller: CMG
1 rerracon
2501 E. Loop 820 North
Fort Worth, Texas 76118
817-268-8600 Reg No: F-3272
Project:
Grapevine Main Phase 1
815 South Main Street
Grapevine, TX 76051
Project No.: 95181011
Technician: Daniel Blocker
Pier Identification
P7/15.7
P6/15.7
P5/15.7
Pier Diameter (in.)
24
24
24
Top of Ground Elevation (ft.)
622.54
622.54
622.54
Top of Pier Elevation (ft.)
619.08
619.08
619.08
Depth to Bearing Stratum from Ground (ft.)
17.0
20.3
17.4
Depth of Pier from Ground (ft.)
34.0
37.3
34.4
Required Penetration (ft.)
17.0
17.0
17.0
Actual Penetration (ft.)
17.0
17.0
17.0
Depth from Top of Concrete (ft.)
30.4
33.7
30.8
Condition of Bottom (wet or dry)
Dry
Dry
Dry
Plumb Within Tolerance (yes or no)
Yes
Yes
Yes
Casing Diameter (in.)
26
26
26
Cased Depth (ft.)
20.0
20.0
20.0
Number of Vertical Bars (ea.)
8
8
8
Reinforcing Bar Size (#)
8
8
8
Length of Vertical Bars (ft.)
33.2
36.1
33.2
Time Drilling was Completed
5:15 PM
4:15 PM
3:28 PM
Time Concrete was Placed
5:45 PM
5:15 PM
4:30 PM
Page 1 of 1
Distribution Page
Report Number: 95181011.0014
Service Date: 02/01/18
Report Date: 02/09/18
Task:
Distribution List
(1) Coury Hospitality, mark@brookshc.com
(1) Manhattan Construction Co, bjensen@manhattanconstruction.com
(1) Manhattan Construction Co, bscheckelhoff@manhattanconstruction.com
(1) Manhattan Construction Co, cpritchard@manhattancontruction.com
(1) Manhattan Construction Co, drideau@manhattanconstruction.com
(1) Manhattan Construction Co, dsaiter@manhattanconstruction.com
(1) Manhattan Construction Co, frederick.moore@manhattanconstruction.com
(1) Manhattan Construction Co, rmontgomery2@manhattanconstruction.com
Irerracon
2501 E Loop 820 N
Fort Worth, TX 76118-6978
817-268-8600
CONCRETE SAMPLE PICK-UP REPORT
Report Number: 95181011.0012A
Irerracon
Service Date: 02/01/18 2501 E Loop 820 N
Report Date: 02/06/18 Fort Worth, TX 76118-6978
817-268-8600 Reg No: F-3272
Client Project
Brooks Hospitality Consulting Corp Grapevine Main Phase 1
Attn: Mark Brooks 815 South Main Street
206 Oldenwood Ct
Colleyville, TX 76034
TOTAL NUMBER OF CONCRETE CYLINDERS PICKED UP: 5
Report No.: 95181011.0012
No. of Cylinders: 1 set of 5 cylinders (4x8)
Services:
Terracon Rep.: Daniel Blocker
Reported To:
Contractor:
Report Distribution:
Grapevine, TX 76051
Project Number: 95181011
(1) Brooks Hospitality Consulting Corp, (1) Manhattan Construction Co, Ben
Mark Brooks Jensen
(1) Manhattan Construction Co, Brad (1) Manhattan Construction Co, Chase Reviewed By:
Scheckelhoff Pritchard
(1) Manhattan Construction Co, Daniel (1) Manhattan Construction Co, David �,Tupa
Rideau Saiter
(1) Manhattan Construction Co, Frederick (1) Manhattan Construction Co, Robert Senior Project Manager
Moore Montaomery
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to
the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
BC0001, 10-16-13, Rev.10 Page 1 of I