HomeMy WebLinkAboutTerracon - 2/14/2018FIELD DENSITY TEST REPORT Irerracon
Report Number: 95181011.0042
Service Date: 02/14/18 2501 E Loop 820 N
Report Date: 02/16/18 Fort Worth, TX 76118-6978
Task: 817-268-8600 Ree No: F-3272
Client Project
Coury Hospitality
Attn: Mark Brooks
7134 S Yale, Ste 400
Tulsa, OK 74136
Grapevine Main Phase 1
815 South Main Street
Grapevine, TX 76051
Project Number: 95181011
Material Information Lab Test Data Project Requirements
Mat. Proctor
No. Ref. No.
1 95181011.0006
Field Test Data
Classification and Description
Dark Reddish Brown Sandy Clay
Test
No. Test Location
Basement (C.5 -G.5/7-9)
Laboratory
Test Method
ASTM D698
Optimum
Water
Max. Lab
Water
Content
Density
Content Compaction
(%)
(pcf)
(%) (%)
18.1
106.4
+3 93-98
Probe Wet Water Water Dry Percent
Lift / Mat. Depth Density Content Content Density Compaction
Elev. No. (in) (pcf) (pcf) (%) (pcf) (%)
1
D.5/8.5
2
1
6
123.3
23.2
23.2
100.1
94
2
F/7.8
2
1
6
123.4
23.0
22.9
100.4
94
3
E/8.5
3
1
6
122.6
22.4
22.4
100.2
94
4
F.5/8.2
3
1
6
122.9
22.2
22.0
100.7
95
5
E.2/8
4
l
6
125.1
23.1
22.6
102.0
96
6
F.6/7.5
4
1
6
124.2
23.3
23.1
100.9
95
Basement (B -E.2/5-7)
7
C/5.6
1
l
6
122.3
22.7
22.8
99.6
94
8
D.1/6.5
1
1
6
122.4
22.6
22.6
99.8
94
9
C/6
2
1
6
122.2
23.2
23.4
99.0
93
10
C.8/6.2
3
1
6
122.7
22.5
22.5
100.2
94
11
D.5/6
4
1
6
123.5
21.5
21.1
102.0
96
Basement (E.2 -G.5-7)
12
F/6.2
1
1
6
122.2
23.1
23.3
99.1
93
Datum: Moisture Condition. Serial No: Std. Cut. M:645 Std. Cut. D: 1836
Comments: Test and/or retest results on this report meet project requirements as noted above.
Services: Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition (ASTM D-6938).
Terracon Rep.: Daniel Moreno
Reported To:
Contractor:
Report Distribution:
See attached distribution list. Reviewed By:
__Lto Tul
Senior Project Manager
Test Methods: ASTM D6938
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
cRoo07, 11-16-12, Rev.7 Page 1 of 1
Distribution Page
Report Number: 95181011.0042
Service Date: 02/14/18
Report Date: 02/16/18
Task:
Distribution List
(1) Coury Hospitality, mark@brookshc.com
(1) City of Grapevine TX, curtisb@grapevinetexas.gov
(1) Manhattan Construction Co, bjensen@manhattanconstruction.com
(1) Manhattan Construction Co, bscheckelhoff@manhattanconstruction.com
(1) Manhattan Construction Co, cpritchard@manhattanconstruction.com
(1) Manhattan Construction Co, drideau@manhattanconstruction.com
(1) Manhattan Construction Co, dsaiter@manhattanconstruction.com
(1) Manhattan Construction Co, frederick.moore@manhattanconstruction.com
(1) Manhattan Construction Co, rmontgomery2@manhattanconstruction.com
Irerracon
2501 E Loop 820 N
Fort Worth, TX 76118-6978
817-268-8600
CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon
Report Number: 95181011.0041
Service Date: 02/14/18 2501 E Loop 820 N
Report Date: 03/20/18 Revision 1 - 28 -day results Fort Worth, TX 76118-6978
Task: 817-268-8600 Ree No: F-3272
Client Project
Coury Hospitality
Attn: Mark Brooks
7134 S Yale, Ste 400
Tulsa, OK 74136
Grapevine Main Phase 1
815 South Main Street
Grapevine, TX 76051
Project Number: 95181011
Age at
Material Information
Compressive
Sample Information
Diam.
Specified Strength: 4,000
psi @
28 days
Sample Date:
02/14/18 Sample Time: 1630
Fracture
No. ID
(in)
Sampled By:
Daniel Blocker
Mix ID: 9211
(lbs)
(psi)
Weather Conditions:
clear
Supplier: argos
12.57
02/21/18
Accumulative Yards:
62 Batch Size (cy): 10
Batch Time: 1534
Plant:
111
Placement Method:
pump
Truck No.: 5114
Ticket No.:
11116247
Water Added Before (gal):
5
Field Test Data
4.00
12.57
Water Added After (gal):
28
82,030
6,530
2
Sample Location:
Pier 2022 @ GL (P1/17)
Test
Result
Specification
Placement Location:
see pier report 0040
Slump (in):
7 1/2
6-8
Air Content (%):
2.1
0-3
1 E
Concrete Temp. (F):
60
50-95
Hold
Ambient Temp. (F):
70
36-100
Plastic Unit Wt. (pcf):
148.8
Yield (Cu. Yds.):
44.8
Laboratory Test Data
Age at
Maximum
Compressive
Set Specimen Avg
Diam.
Area
Date Date
Test
Load
Strength
Fracture
No. ID
(in)
(sq in)
Received Tested
(days)
(lbs)
(psi)
Type
1 A
4.00
12.57
02/21/18
7
58,030
4,620
4
1 B
4.00
12.57
03/14/18
28
81,320
6,470
5
1 C
4.00
12.57
03/14/18
28
82,030
6,530
2
1 D
4.00
12.57
03/14/18
28
84,190
6,700
4
Average
(28 days)
6,570
1 E
Hold
Initial Cure: Outside
Final Cure: Moist Room
Comments: Average compressive strength of 28 day cylinders complies with the specified strength.
Samples Made By: Terracon
Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength
samples.
Terracon Rep.: Daniel Blocker
Reported To:
Contractor: Manhattan
Report Distribution:
See attached distribution list.
Reviewed By:
Senior Project Manager
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
Cx000t, 11-16-12, xev.6 Page 1 of 1
Distribution Page
Report Number: 95181011.0041
Service Date: 02/14/18
Report Date: 03/20/18 Revision 1 - 28 -day results
Task:
Distribution List
(1) Coury Hospitality, mark@brookshc.com
(1)AECC Inc, leel@aeccinc.com
(1) City of Grapevine TX, curtisb@grapevinetexas.gov
(1) Manhattan Construction Co, bjensen@manhattanconstruction.com
(1) Manhattan Construction Co, bscheckelhoff@manhattanconstruction.com
(1) Manhattan Construction Co, cpritchard@manhattanconstruction.com
(1) Manhattan Construction Co, drideau@manhattanconstruction.com
(1) Manhattan Construction Co, dsaiter@manhattanconstruction.com
(1) Manhattan Construction Co, frederick.moore@manhattanconstruction.com
(1) Manhattan Construction Co, rmontgomery2@manhattanconstruction.com
Irerracon
2501 E Loop 820 N
Fort Worth, TX 76118-6978
817-268-8600
CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon
Report Number: 95181011.0041
Service Date: 02/14/18 2501 E Loop 820 N
Report Date: 02/27/18 Fort Worth, TX 76118-6978
Task: 817-268-8600 Ree No: F-3272
Client Project
Coury Hospitality
Attn: Mark Brooks
7134 S Yale, Ste 400
Tulsa, OK 74136
Grapevine Main Phase 1
815 South Main Street
Grapevine, TX 76051
Project Number: 95181011
Material Information Sample Information
Specified Strength: 4,000 psi @ 28 days
Mix ID: 9211
Supplier: argos
Batch Time: 1534 Plant: 111
Truck No.: 5114 Ticket No.: 11116247
Field Test Data
Test
Result
Specification
Slump (in):
7 1/2
6-8
Air Content (%):
2.1
0-3
Concrete Temp. (F):
60
50-95
Ambient Temp. (F):
70
36-100
Plastic Unit Wt. (pcf):
148.8
12.57
Yield (Cu. Yds.):
44.8
Laboratory Test Data
Set Specimen
Avg Diam.
Area
No. ID
(in)
(sq in)
1 A
4.00
12.57
1 B
4.00
12.57
1 C
4.00
12.57
1 D
4.00
12.57
1 E
Hold
Initial Cure: Outside
Comments:
Sample Date:
Sampled By:
Weather Conditions:
Accumulative Yards:
Placement Method:
Water Added Before (gal):
Water Added After (gal):
Sample Location:
Placement Location:
02/14/18 Sample Time: 1630
Daniel Blocker
clear
62 Batch Size (cy): 10
PUMP
Pier 2022 @ GL (P1/17)
see pier report 0040
Age at Maximum
Date Date
Test
Load
Received Tested
(days)
(lbs)
02/21/18
7
58,030
03/14/18
28
03/14/18
28
03/14/18
28
Hold
Final Cure: Moist Room
Compressive
Strength Fracture
(psi) Type
4,620 4
Samples Made By: Terracon
Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength
samples.
Terracon Rep.: Daniel Blocker
Reported To:
Contractor: Manhattan
Report Distribution:
See attached distribution list.
Reviewed By:
Senior Project Manager
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
Cx000t, 11-16-12, xev.6 Page 1 of 1
Distribution Page
Report Number: 95181011.0041
Service Date: 02/14/18
Report Date: 02/27/18
Task:
Distribution List
(1) Coury Hospitality, mark@brookshc.com
(1) City of Grapevine TX, curtisb@grapevinetexas.gov
(1) Manhattan Construction Co, bjensen@manhattanconstruction.com
(1) Manhattan Construction Co, bscheckelhoff@manhattanconstruction.com
(1) Manhattan Construction Co, cpritchard@manhattanconstruction.com
(1) Manhattan Construction Co, drideau@manhattanconstruction.com
(1) Manhattan Construction Co, dsaiter@manhattanconstruction.com
(1) Manhattan Construction Co, frederick.moore@manhattanconstruction.com
(1) Manhattan Construction Co, rmontgomery2@manhattanconstruction.com
Irerracon
2501 E Loop 820 N
Fort Worth, TX 76118-6978
817-268-8600
DRILLED PIER OBSERVATION REPORT
Report Number: 95181011.0040
Irerracon
Service Date: 02/14/18 2501 E Loop 820 N
Report Date: 07/02/18 Revision 1 - rebar Fort Worth, TX 76118-6978
817-268-8600 Reg No: F-3272
Client Project
Coury Hospitality Grapevine Main Phase 1
Attn: Mark Brooks 815 South Main Street
7134 S Yale, Ste 400 Grapevine, TX 76051
Tulsa, OK 74136
Proiect Number: 95181011
On this date, a Terracon technician arrived at the above referenced jobsite as scheduled for Drilled Pier Observation. See attached sheet
for recorded data.
NOTE: Elevation data provided by others or taken from plans.
Services: Drilled Pier Observation
Terracon Rep.: Daniel Blocker
Reported To:
Contractor: Manhattan
Report Distribution:
See attached distribution list.
Reviewed By:
�,Tuipa
Senior Project Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to
the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
sC0001, 10-16-13, Rev.10 Page 1 of 1
DRILLED PIER OBSERVATION
Report Number: 95181011.0040
Service Date: February 14, 2018
Client: Brooks Hospitality Consulting Corp
Attn: Mark Brooks
206 Oldenwood Ct
Colleyville, TX 76034
Driller: CMG
1 rerracon
2501 E. Loop 820 North
Fort Worth, Texas 76118
817-268-8600 Reg No: F-3272
Project:
Grapevine Main Phase 1
815 South Main Street
Grapevine, TX 76051
Project No.: 95181011
Technician: Daniel Blocker
Pier Identification
P1/17
P7/18
P8/18
Pier Diameter (in.)
60
36
36
Top of Ground Elevation (ft.)
630.85
628.61
628.44
Top of Pier Elevation (ft.)
626.58
624.25
624.25
Depth to Bearing Stratum from Ground (ft.)
31.0
30.0
25.0
Depth of Pier from Ground (ft.)
61.3
53.9
48.0
Required Penetration (ft.)
30.0
23.0
23.0
Actual Penetration (ft.)
30.3
23.9
23.0
Depth from Top of Concrete (ft.)
57.7
48.4
44.4
Condition of Bottom (wet or dry)
Dry
Dry
Dry
Plumb Within Tolerance (yes or no)
Yes
Yes
Yes
Casing Diameter (in.)
62
38
38
Cased Depth (ft.)
28.0
30.0
27.0
Number of Vertical Bars (ea.)
16
12
12
Reinforcing Bar Size (#)
10
9
9
Length of Vertical Bars (ft.)
59.5
52.4
46.3
Time Drilling was Completed
1:40 PM
9:30 AM
11:30 AM
Time Concrete was Placed
5:40 PM
1:45 PM
2:40 PM
Page 1 of 1
Distribution Page
Report Number: 95181011.0040
Service Date: 02/14/18
Report Date: 07/02/18 Revision 1 - rebar
Task:
Distribution List
(1) Coury Hospitality, Mark Brooks
(1) AECC Inc, Lee Ledet
(1) ArchiTexas, Michael Karnowski
(1) City of Grapevine TX, Curtis A Bergthold
(1) Construction Management Group of Fair Oaks CA, Blake Cearley
(1) JQ Engineering, Mike Oler
(1) Manhattan Construction Co, Ben Jensen
(1) Manhattan Construction Co, Brad Scheckelhoff
(1) Manhattan Construction Co, Chase Pritchard
(1) Manhattan Construction Co, Daniel Rideau
(1) Manhattan Construction Co, David Saiter
(1) Manhattan Construction Co, Frederick Moore
(1) Manhattan Construction Co, Robert Montgomery
Irerracon
2501 E Loop 820 N
Fort Worth, TX 76118-6978
817-268-8600
DRILLED PIER OBSERVATION REPORT
Report Number: 95181011.0040
Irerracon
Service Date: 02/14/18 2501 E Loop 820 N
Report Date: 02/16/18 Fort Worth, TX 76118-6978
817-268-8600 Reg No: F-3272
Client Project
Coury Hospitality Grapevine Main Phase 1
Attn: Mark Brooks 815 South Main Street
7134 S Yale, Ste 400 Grapevine, TX 76051
Tulsa, OK 74136
Proiect Number: 95181011
On this date, a Terracon technician arrived at the above referenced jobsite as scheduled for Drilled Pier Observation. See attached sheet
for recorded data.
NOTE: Elevation data provided by others or taken from plans.
Services: Drilled Pier Observation
Terracon Rep.: Daniel Blocker
Reported To:
Contractor: Manhattan
Report Distribution:
See attached distribution list.
Reviewed By:
�,Tuipa
Senior Project Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to
the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
sC0001, 10-16-13, Rev.10 Page 1 of 1
DRILLED PIER OBSERVATION
Report Number: 95181011.0040
Service Date: February 14, 2018
Client: Brooks Hospitality Consulting Corp
Attn: Mark Brooks
206 Oldenwood Ct
Colleyville, TX 76034
Driller: CMG
1 rerracon
2501 E. Loop 820 North
Fort Worth, Texas 76118
817-268-8600 Reg No: F-3272
Project:
Grapevine Main Phase 1
815 South Main Street
Grapevine, TX 76051
Project No.: 95181011
Technician: Daniel Blocker
Pier Identification
P1/17
P7/18
P8/18
Pier Diameter (in.)
60
36
36
Top of Ground Elevation (ft.)
630.85
628.61
628.44
Top of Pier Elevation (ft.)
626.58
624.25
624.25
Depth to Bearing Stratum from Ground (ft.)
31.0
30.0
25.0
Depth of Pier from Ground (ft.)
61.3
53.9
48.0
Required Penetration (ft.)
30.0
23.0
23.0
Actual Penetration (ft.)
30.3
23.9
23.0
Depth from Top of Concrete (ft.)
57.7
48.4
44.4
Condition of Bottom (wet or dry)
Dry
Dry
Dry
Plumb Within Tolerance (yes or no)
Yes
Yes
Yes
Casing Diameter (in.)
62
38
38
Cased Depth (ft.)
28.0
30.0
27.0
Number of Vertical Bars (ea.)
16
16
16
Reinforcing Bar Size (#)
10
10
10
Length of Vertical Bars (ft.)
59.5
52.4
46.3
Time Drilling was Completed
1:40 PM
9:30 AM
11:30 AM
Time Concrete was Placed
5:40 PM
1:45 PM
2:40 PM
Page 1 of 1
Distribution Page
Report Number: 95181011.0040
Service Date: 02/14/18
Report Date: 02/16/18
Task:
Distribution List
(1) Coury Hospitality, mark@brookshc.com
(1) City of Grapevine TX, curtisb@grapevinetexas.gov
(1) Manhattan Construction Co, bjensen@manhattanconstruction.com
(1) Manhattan Construction Co, bscheckelhoff@manhattanconstruction.com
(1) Manhattan Construction Co, cpritchard@manhattanconstruction.com
(1) Manhattan Construction Co, drideau@manhattanconstruction.com
(1) Manhattan Construction Co, dsaiter@manhattanconstruction.com
(1) Manhattan Construction Co, frederick.moore@manhattanconstruction.com
(1) Manhattan Construction Co, rmontgomery2@manhattanconstruction.com
Irerracon
2501 E Loop 820 N
Fort Worth, TX 76118-6978
817-268-8600
CONCRETE SAMPLE PICK-UP REPORT
Report Number: 95181011.0039A
Irerracon
Service Date: 02/14/18 2501 E Loop 820 N
Report Date: 02/16/18 Fort Worth, TX 76118-6978
817-268-8600 Reg No: F-3272
Client Project
Coury Hospitality Grapevine Main Phase 1
Attn: Mark Brooks 815 South Main Street
7134 S Yale, Ste 400 Grapevine, TX 76051
Tulsa, OK 74136
Project Number: 95181011
TOTAL NUMBER OF CONCRETE CYLINDERS PICKED UP: 5
ReportNo.: 95181011.0039
No. of Cylinders: 1 set of 5 (4x8)
Services:
Terracon Rep.: Daniel Blocker
Reported To:
Contractor:
Report Distribution:
See attached distribution list.
Reviewed By:
�,T
Senior Project Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to
the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
sC0001, 10-16-13, Rev.10 Page 1 of I
Distribution Page
Report Number: 95181011.0039A
Service Date: 02/14/18
Report Date: 02/16/18
Task:
Distribution List
(1) Coury Hospitality, mark@brookshc.com
(1) City of Grapevine TX, curtisb@grapevinetexas.gov
(1) Manhattan Construction Co, bjensen@manhattanconstruction.com
(1) Manhattan Construction Co, bscheckelhoff@manhattanconstruction.com
(1) Manhattan Construction Co, cpritchard@manhattanconstruction.com
(1) Manhattan Construction Co, drideau@manhattanconstruction.com
(1) Manhattan Construction Co, dsaiter@manhattanconstruction.com
(1) Manhattan Construction Co, frederick.moore@manhattanconstruction.com
(1) Manhattan Construction Co, rmontgomery2@manhattanconstruction.com
Irerracon
2501 E Loop 820 N
Fort Worth, TX 76118-6978
817-268-8600