Loading...
HomeMy WebLinkAboutTerracon - 8/06/2018CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 95181011.0396 Service Date: 08/06/18 2501 E Loop 820 N Report Date: 08/07/18 Fort Worth, TX 76118-6978 Task: 817-268-8600 Ree No: F-3272 Client Project Coury Hospitality Attn: Mark Brooks 7134 S Yale, Ste 400 Tulsa, OK 74136 Grapevine Main Phase 1 815 South Main Street Grapevine, TX 76051 Project Number: 95181011 Material Information Sample Information Specified Strength: 7,000 psi @ 28 days Mix ID: D 10000009908 Supplier: Argos Batch Time: 1527 Plant: 123 Truck No.: 5106 Ticket No.: 12331558 Field Test Data Test Result Specification Slump (in): 61/4 * 3-5 Air Content (%): 1.3 0-3 Concrete Temp. (F): 95 50-104 Ambient Temp. (F): 97 28 Plastic Unit Wt. (pcf): 152.6 28 Yield (Cu. Yds.): * = Field Test Results do not meet project specifications. Laboratory Test Data Set Specimen Avg Diam. No. ID (in) 1 A 4.00 1 B 4.00 1 C 4.00 1 D 4.00 1 E 28 Initial Cure: Outside 09/03/18 Comments: Samples Made By: Terracon Sample Date: 08/06/18 Sample Time: 1555 Sampled By: Jalil Edwards Weather Conditions: Mostly Cloudy Accumulative Yards: 9/9 Batch Size (cy): 9 Placement Method: Bucket & lift Water Added Before (gal): 0 Water Added After (gal): 0 Sample Location: Station at gridline G.4/7 Placement Location: Rail station area way slab & beam gridlines G.3/H - 7 Age at Maximum Area Date Date Test Load (sq in) Received Tested (days) (lbs) 12.57 08/13/18 7 12.57 09/03/18 28 12.57 09/03/18 28 12.57 09/03/18 28 Hold Final Cure: Moist Room Compressive Strength Fracture Tested (psi) Type By Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Jalil Edwards Reported To: David with Manhattan Contractor: Manhattan Report Distribution: See attached distribution list. Reviewed By: Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cx000t, 11-16-12, xev.6 Page 1 of 1 Distribution Page Report Number: 95181011.0396 Service Date: 08/06/18 Report Date: 08/07/18 Task: Distribution List (1) Coury Hospitality, Mark Brooks (1) AECC Inc, Lee Ledet (1) ArchiTexas, Michael Karnowski (1) City of Grapevine TX, Curtis A Bergthold (1) Construction Management Group of Fair Oaks CA, Blake Cearley (1) JQ Engineering, Mike Oler (1) Manhattan Construction Co, Ben Jensen (1) Manhattan Construction Co, Brad Scheckelhoff (1) Manhattan Construction Co, Chase Pritchard (1) Manhattan Construction Co, Daniel Rideau (1) Manhattan Construction Co, David Saiter (1) Manhattan Construction Co, Frederick Moore (1) Manhattan Construction Co, Robert Montgomery Irerracon 2501 E Loop 820 N Fort Worth, TX 76118-6978 817-268-8600