Loading...
HomeMy WebLinkAboutTerracon - 8/08/2018FIELD DENSITY TEST REPORT Irerracon Report Number: 95181011.0398 Service Date: 08/08/18 2501 E Loop 820 N Report Date: 08/09/18 Fort Worth, TX 76118-6978 Task: 817-268-8600 Ree No: F-3272 Client Project Coury Hospitality Attn: Mark Brooks 7134 S Yale, Ste 400 Tulsa, OK 74136 Grapevine Main Phase 1 815 South Main Street Grapevine, TX 76051 Project Number: 95181011 Material Information Lab Test Data Project Requirements Optimum Water Max. Lab Water Mat. Proctor Laboratory Content Density Content Compaction No. Ref. No. Classification and Description Test Method (%) (pcf) (%) (%) 1 95181011.0235 Brown Sandy Clay with Trace of ASTM D698 15.5 113.3 Opt - +3 Min 95% LSF 2 95181011.0006 Dark Reddish Brown Sandy Clay ASTM D698 18.1 106.4 Min/+3 Min 93% Field Test Data Probe Wet Water Water Dry Percent Test Lift / Mat. Depth Density Content Content Density Compaction No. Test Location Elev. No. (in) (pct) (pct) (%) (pct) (%) 8" Sanitary sewer line 127 Sta 0+50 (Potholed) -8 1 12 127.5 17.1 15.5 110.4 97 128 -7 1 12 128.6 17.6 15.9 111.0 98 129 -6 1 12 129.5 17.4 15.5 112.1 99 130 -5 1 12 130.7 17.7 15.7 113.0 100 131 -4 1 12 128.4 17.3 15.6 111.1 98 132 -3 1 12 129.6 17.6 15.7 112.0 99 133 -2 1 12 127.5 17.1 15.5 110.4 97 134 -1 1 12 130.5 17.6 15.6 112.9 100 Exterior Wall Backfill 135 P4.5/13.7 (Potholed) -6 2 12 123.4 23.9 24.0 99.5 94 136 -5 2 12 125.4 22.7 22.1 102.7 97 137 -4 2 12 122.4 22.8 22.9 99.6 94 Datum: Std. Cnt. M:672 Std. Cut. D: 2633 S/N: 70708 Make: Troxler Model: 3440P Last Cal. Date: 03,128/2018 Comments: Test and/or retest results on this report meet project requirements as noted above. Services: Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition (ASTM D-6938). Terracon Rep.: Daniel Wright Reported To: David with Manhattan, Wright Construction Contractor: Manhattan Report Distribution: See attached distribution list. Reviewed By: __Lto Tul Senior Project Manager Test Methods: ASTM D6938 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cRoo07, 11-16-12, Rev.7 Page 1 of 1 Distribution Page Report Number: 95181011.0398 Service Date: 08/08/18 Report Date: 08/09/18 Task: Distribution List (1) Coury Hospitality, Mark Brooks (1) AECC Inc, Lee Ledet (1) ArchiTexas, Michael Karnowski (1) City of Grapevine TX, Curtis A Bergthold (1) Construction Management Group of Fair Oaks CA, Blake Cearley (1) JQ Engineering, Mike Oler (1) Manhattan Construction Co, Ben Jensen (1) Manhattan Construction Co, Brad Scheckelhoff (1) Manhattan Construction Co, Chase Pritchard (1) Manhattan Construction Co, Daniel Rideau (1) Manhattan Construction Co, David Saiter (1) Manhattan Construction Co, Frederick Moore (1) Manhattan Construction Co, Robert Montgomery Irerracon 2501 E Loop 820 N Fort Worth, TX 76118-6978 817-268-8600