Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 1/31/2017 (2)2324 Fabens Rd I c n 75225 Li il l t w YA GeL21 352..4. - tQ�(D Fax. 214 352: 4811 REPORT OF FIELD COMPACTION Page i oft Tested For: JLB Partners, LP Date Performed: 1/31/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Gr'a, e"~v ine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-50OIEG Probe Depth: 8 Inches Moisture -Density Relations Proctor No. Material Description Opt. MQ0%) Max DD (pcn DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pcf) Moisture Density 484 9TH BLDG. PAD 2 GRID POINT K,8-36.4 (S. SITE GRID) 1 100.8 22.9 95.5 485 10TH BLDG. PAD 2 GRID POINT K.,7-36.8 (S.. SITE GRID) 3 100.4 23.5 97..4 486 11TH BLDG, PAD 2 GRID POINT K-36.7 (S, SITE GRID) 3 97 24 94.1 487 12TH BLDG, PAD 2 GRID POINT K.6-36„7 (S:, SITE GRID) 3 97.6 24.2 94.7 488 13TH BLDG, PAD 2 GRID POINT K.6-36,4 (S. SITE GRID) 1 98.4 23 93.3 489 SG BLDG. PAD 2 GRID POINT K,4-35.4 (S. SITE GRID) 1 98.2 22.9 931 490 IST BLDG, PAD 2 GRID POINT K 1-35,6 (S. SITE GRID) 3 97.3 23.7 94.4 491 SG BLDG, PAD 2 GRID POINT M.6-35,7 (S.. SITE GRID) 1 98.5 23.3 93,4 492 1ST BLDG. PAD 2 GRID POINT M,4-35,4 (S:, SITE GRID) 3 97 23.5 94.1 493 2ND BLDG. PAD 2 GRID POINT K 4-35.6 (S. SITE GRID) 3 97.7 24.1 94.8 494 3RD BLDG, PAD 2 GRID POINT K.,7-35.4 (S. SITE GRID) 3 96.1 24.6 93.2 495 2ND BLDG. PAD 2 GRID POINT M.6-35.7 (S, SITE GRID) 3 97 23.8 94„1 496 3RD BLDG. PAD 2 GRID POINT M-35 (S. SITE GRID) 3 96.4 24.3 93.5 497 10TH BLDG, PAD 18 GRID POINT K,6-20.7 (S, SITE GRID) 3 97,1 24.8 94.2 498 11TH BLDG. PAD 18 GRID POINT K.4-20.7 (S. SITE GRID) 3 96.9 24.6 94 499 12TH BLDG. PAD 18 GRID POINT K 7-20.6 (S. SITE GRID) 3 97.3 24 94.4 500 13TH BLDG.. PAD 18 GRID POINT K.6-20.1 (S.. SITE GRID) 1 98.8 23.2 93.6 501 SG BLDG. PAD 18 GRID POINT K,4-18.6 (S. SITE GRID) 1 99.2 22.9 94 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering e Cone•l *lion Materials Testing a Environmental Services www.dallaifar,qo.com R,`900 2324 Faberi:, 1W. - Halla F'cxas'75221, 1 , - '0111,11 , ", --- - .­ ........... . VA I ( G'I � C,'O P�4 K V 1 -TA N TS, 1W Q 'T'el. 214-352-4100 Fqx, 214-352-4811 REPORT OF FIELD COMPACTION Page 2 of 2 Tested For: JLB Partners, LP Date Performed: 1/31/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M 16-4962 Gr!Eevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS -5001E7_ Probe Depth: 8 Inches Test Elevation Proctor DryDensity Percent Percent No. ILft Location No. (P cfi Moisture Density 502 1ST BLDG. PAD 18 GRID POINT K,6-18.4 (S, SITE GRID) 3 96.5 24.2 93.6 503 SG BLDG, PAD 18 GRID POINT L-18.1 (S. SITE GRID) 1 98.6 23.1 93.5 504 1ST BLDG. PAD 18 GRID POINT L.4-18,6 (S, SITE GRID) 3 96 24.5 93.1 505 2ND BLDG PAD 18 GRID POINT K,1-18,3 (S. SITE GRID) 3 98.2 233 95.2 506 3RD BLDG PAD 18 GRID POINT K,6-18.7 (S. SITE GRID) 3 99.8 23.5 96.8 507 2ND BLDG PAD 18 GRID POINT L,7-18 (S. SITE GRID) 3 97.5 24.2 94.6 508 3RD BLDG PAD 18 GRID POINT L-18,6 (S SITE GRID) 3 96.8 23.7 93.9 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Test result with asterisk (*), it"any, indicates non-comiultance to provided guidelines. Fargo Convultants, Inc. Z7 Test locations are referenced using an in-house system and are approximate. CET 1Moore, 1�41:1:rials Testing Division The information and results shown on this :report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on. data obtained froin specific samples tested at. Particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, pc,rforrnance, etc. The use of our name and test rCSU11S MUSt I-CCCiVe our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering ® Construction Materials Testing - Environmental Servicer wwv.dallasfareo.com