Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 1/30/2017 (3)......- - - - ., .------ _� -_ _ ...... .._ _... 2"Lf I�abens Rd. I 1 �Gd..... uw � Texas 75225 VAWWw arum+a r,N A e ,, tt+o. 1 cL 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Pagel of Tested For: JLB Partners, LP Date Performed: 1/30/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Gra evine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS -5001 EZ Probe Depth: 8 Inches Moisture -Density Relations Proctor No. Material Description Opt. MC(%) Max DD (pcj) DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 4 Dark Brown and Tan and reddish Brown CLAY (mix) 22.4 96.8 93 to 98 at least +4 5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8 106.1 93 to 98 at least +4 7 Brown CLAYEY SAND - Select Fill 14.3 114 Min. 95 -2 to +2 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pcfl Moisture Density 449 FG BLDG. PAD 1 GRID POINT Q.4-36 IS, SITE GRID) 7 112.6 15.7 98.8 450 FG BLDG, PAD 1 GRID POINT Q.5-34 6 (S, SITE GRID) 7 110.8 15.3 97.2 451 FG BLDG, PAD 1 GRID POINT R,1-33.4 IS, SITE GRID) 7 108.5 16.2 95.2 452 FG BLDG, PAD 1 GRID POINT R.6-31.6 IS, SITE GRID) 7 111.9 14,2 98.2 453 FG BLDG, PAD 1 GRID POINT Q.1-29,4 (S, SITE GRID) 7 112.4 14 98.6 454 FG BLDG. PAD 1 GRID POINT Q_6-26,6 (S, SITE GRID) 7 113.1 13.6 99.2 455 FG BLDG. PAD 1 GRID POINTS 1-257 IS. SITE GRID) 7 113.8 12.9 99.8 456 FG BLDG, PAD 1 GRID POINT S.6-26.1 (S. SITE GRID) 7 109.9 13.2 96.4 457 FG BLDG, PAD 1 GRID POINT U.7-34,6 IS, SITE GRID) 7 112.3 15.4 98.5 458 FG BLDG„ PAD 1 GRID POINT X-35 (S. SITE GRID) 7 110.4 15.2 96.8 459 FG BLDG, PAD 1 GRID POINT Y.1-36.4 IS. SITE GRID) 7 111.5 14.1 97.8 460 FG BLDG. PAD 1 GRID POINT T.6-27,6 (S. SITE GRID) 7 110.7 14.8 97.1 461 FG BLDG, PAD 1 GRID POINT U,3-25.1 (S. SITE GRID) 7 109.8 15 96.3 462 FG BLDG, PAD 1 GRID POINT X.2-26.8 (S. SITE GRID) 7 109.1 15.3 95.7 463 FG BLDG, PAD 1 GRID POINT Z-26,7 IS, SITE GRID) 7 111.2 14.6 97.5 464 SG BLDG. PAD 2 GRID POINT K.4-36.1 (S. SITE GRID) 4 93.2 26.4 96.3 465 SG BLDG, PAD 2 GRID POINT K.6-36.6 (S. SITE GRID) 3 97.4 23.9 94.5 The information and results shown on this report arc for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering ® Construction Materials Testing - Environmental Services ivwm dalla.r farko. com xis xn d ana��vru uatrx r;i wx" [21. 21�4�35 41(}0 1_x214-352-4811i REPORT OF FIELD COMPACTION Page 2 of 2 Tested For: JLB Partners, LP Date Performed: 1/30/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Gra Seville., Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt "fest Mode: Direct Transmission Gauge Model: HS-50OIEZ Probe Depth:8 Inches Test Elevation Proctor DryDensity Percent Percent No. (Lift Location No. (pcf) Moisture Density 466 1ST BLDG, PAD 2 GRID POINT K,4-36.6 (S, SITE GRID) 3 98.1 24.1 95.2 467 2ND BLDG, PAD 2 GRID POINT K.8-36 (S. SITE GRID) 4 91.2 26.9 94.2 468 3RD BLDG, PAD 2 GRID POINT K,4-36.7 (S, SITE GRID) 3 98.9 23.4 95.9 469 4TH BLDG. PAD 2 GRID POINT K.6-36,2 (S. SITE GRID) 1 99.4 22.9 94.2 470 5TH BLDG PAD 2 GRID POINT K.7-36,6 (S, SITE GRID) 3 97.6 237 94.7 471 6TH BLDG. PAD 2 GRID POINT K.6-36.4 (S. SITE GRID) 4 90.6 26.4 93.6 472 7TH BLDG, PAD 2 GRID POINT K..6-36.6 (S. SITE GRID) 3 96.7 24.5 93.8 473 8TH BLDG, PAD 2 GRID POINT K.4-36.7 (S. SITE GRID) 3 98.2 24.1 95.2 474 SG BLDG, PAD 18 GRID POINT K..6 -20A (S. SITE GRID) 5 99.5 20.8 93.8 475 1ST BLDG. PAD 18 GRID POINT K-20 (S. SITE GRID) 3 96.9 24.6 94 476 2ND BLDG. PAD 18 GRID POINT K.4-20,1 (S, SITE GRID) 4 93.4 26.9 96.5 477 3RD BLDG. PAD 16 GRID POINT K_4-20.8 (S. SITE GRID) 3 96 23.8 93.1 478 4TH BLDG. PAD 18 GRID POINT K,6-20,4 (S. SITE GRID) 4 93.1 26.4 96.2 479 5TH BLDG. PAD 18 GRID POINT K..6-20.6 (S. SITE GRID) 4 92.5 27.2 95.6 480 6TH BLDG, PAD 18 GRID POINT K,7-20,1 (S. SITE GRID) 3 96.9 23.7 94 481 7TH BLDG. PAD 18 GRID POINT K.9-207 IS, SITE GRID) 3 97.3 24.2 94.4 482 8TH BLDG. PAD 18 GRID POINT K,7-20..2 (S„ SITE GRID) 3 97.5 23.7 94.6 483 9TH BLDG, PAD 18 GRID POINT K.1-20,3 (S. SITE GRID) 3 95.9 24.3 93 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo Consnlla ts°, Inc. 'fest result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. 714 C:rr y Moore, CE laterrials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipiew s on file in our office. Pest results are based on data obtained from specific samples tested at particular locations noted and are not indicative ofthe dualities of apparently identical or similar specimens, composition, performance, etc. 'I'lie use of our name and test results must receive our written appraval. Deports must be reproduced in their entirety. Geotechnical Engineering s Construction Materials Testing s Environmental Servicer www. dallasiarffo. com