Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 1/28/2017 (2)--- ...,,,... - _ .. ....�����4lialnan 1Ld. P�rllu.b l� 7�91r ...� .. , _.. FARGO COWSUT.TANTS, INC ..__ t cl 214 352 4100 1 ax:.. 211=4 352 48111 REPORT OF FIELD COMPACTION Page 1 of 2 Tested For: JLB Partners, LP Date Performed: 1/28/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Gra evine, Texas Density and Moisture: Per ASTM D-6936 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: S-5001 EZ Probe Depth: 8 Inches Moisture -Density Relations Proctor No. Material Description Opt. MC(%) Max DD (pcfi DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 4 Dark Brown and Tan and reddish Brown CLAY (mix) 22.4 96.8 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pcfi Moisture Density 425 8TH BLDG PAD 18 GRID POINT K.3-21.7 (S. SITE GRID) 3 98,4 23.7 95.4 426 9TH BLDG, PAD 18 GRID POINT K.4-21.4 (S.. SITE GRID) 3 98.1 24.4 95,2 427 8TH BLDG, PAD 18 GRID POINT L-21,2 (S, SITE GRID) 3 99.1 23,4 961 428 9TH BLDG, PAD 18 GRID POINT L,6-21,3 (S. SITE GRID) 3 97.5 23.5 94.6 429 10TH BLDG, PAD 18 GRID POINT K,1-21.1 (S. SITE GRID) 4 93.8 26.4 96.9 430 11TH BLDG, PAD 18 GRID POINT K7-21,7 (S. SITE GRID) 3 99.6 23.3 96.6 431 10TH BLDG, PAD 18 GRID POINT L,3-21 (S. SITE GRID) 3 97 23.5 94.1 432 11TH BLDG, PAD 18 GRID POINT L.,1-21.4 (S, SITE GRID) 3 96.9 23.9 94 433 12TH BLDG. PAD 18 GRID POINT K.4-21.5 (S, SITE GRID) 1 100.6 22.9 95.4 434 13TH BLDG PAD 18 GRID POINT K.3-21.8 (S. SITE GRID) 1 99.4 23.5 94.2 435 12TH BLDG. PAD 18 GRID POINT LA -21A (S, SITE GRID) 3 97 23.4 94.1 436 13TH BLDG, PAD 18 GRID POINT L.3-21,3 (S. SITE GRID) 1 100.1 23 94.9 437 8TH BLDG. PAD 2 GRID POINT L-37.7 (S. SITE GRID) 1 98.8 22.9 93.6 438 9TH BLDG. PAD 2 GRID POINT L.,4-37.3 (S. SITE GRID) 3 97.4 23.9 94.5 439 8TH BLDG. PAD 2 GRID POINT K.6-37.4 (S, SITE GRID) 1 98.3 23.1 93.2 440 9TH BLDG PAD 2 GRID POINT K 1-37.5 (S. SITE GRID) 3 98.6 23.3 95.6 441 10TH BLDG, PAD 2 GRID POINT L,6-37,1 IS SITE GRID) 3 98.1 23.7 95.2 442 11TH BLDG. PAD 2 GRID POINT L_7-37 5 (S. SITE GRID) 3 98 23.3 95.1 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Etagineering ®Construction IVlaterials 'lasting ° environmental Servicer www.dallasfark.,o.com 'ab n iia iii r7, Niia INC I cl.127�4c352 41 00 -1'ax ' 1 G a, r '' 7221 _._ 2t4 ,i�2 4811 REPORT OF FIELD COMPACTION Page 2 of 2 Tested For: JLB Partners, LP Date Performed: 1/28/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Test Elevation Proctor DryDensity Percent Percent No. ILift Location No. (pcf) Moisture Density 443 12TH BLDG, PAD 2 GRID POINT L,6-37.8 (S, SITE GRID) 3 97.7 23.5 94.8 444 10TH BLDG, PAD 2 GRID POINT K,9-37.7 (S SITE GRID) 3 97.5 23.9 94.6 445 11TH BLDG PAD 2 GRID POINT K.2-37,4 (S. SITE GRID) 3 96.1 24.2 93.2 446 12TH BLDG, PAD 2 GRID POINT K,8-37,5 IS. SITE GRID) 3 97 23.4 94.1 447 13TH BLDG, PAD 2 GRID POINT K.1 -37,b IS SITE GRID) 1 99.3 22.9 94.1 448 13TH BLDG, PAD 2 GRID POINT L.3-37.2 IS, SITE GRID) 1 99.8 23.3 94,6 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted% Fargo Consultants, Inc. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. 1MoorG( e, CET Iateriaals Testing Division I he information and results shown on this report are for the exclusive use ofthe client and the client'; designated recipients on file in our office Test results are based on data obtained from specific samples tested at particular location noted and are not indicative of the dualities of apparently identical or :similar specimens, composition., performance, etc. The use of our name and teat results must receive our written approval. IZcriorts rust be reproduced in their entirety. Geotechnical Enpneeriy�g A Gonsi action Materials "Testing ® Environmental Semicos www. dalla l' frim. com