Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 2/8/2017F71P20 FARGO CONSUI.TANTS, INC, 2324 Fabens Rd. • LMI:Ds,'fexas 7522: Tel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page I oft Tested For: JLB Partners, LP Date Performed: 2/8/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Moisture -Density Relations Proctor No. Material Description Opt. MC(Vo) Max DD (pen DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 4 Dark Brown and Tan and reddish Brown CLAY (mix) 22.4 96.8 93 to 98 at least +4 5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8 106.1 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pcfi Moisture Density 692 6TH BLDG. PAD 13 GRID POINT K.1-21.4 (N. SITE GRID) 3 96.2 23.6 93.3 693 6TH BLDG. PAD 13 GRID POINT K-23.1 (N. SITE GRID) 3 96.4 23.5 93.5 694 7TH BLDG. PAD 13 GRID POINT K.5-21 (N. SITE GRID) 1 99.5 23.1 94.3 695 7TH BLDG, PAD 13 GRID POINT K.7-23.6 (N. SITE GRID) 3 98.4 23.4 95.4 696 8TH BLDG. PAD 13 GRID POINT K.6-21.6 (N. SITE GRID) 1 99.2 23.1 94 697 8TH BLDG. PAD 13 GRID POINT K2-23.4 (N. SITE GRID) 1 99.1 23.2 93,9 698 9TH BLDG. PAD 13 GRID POINT K.1-21.6 (N. SITE GRID) 3 97.2 23.5 94.3 699 9TH BLDG. PAD 13 GRID POINT K-23,1 (N. SITE GRID) 1 98.3 23.2 93.2 700 10TH BLDG. PAD 13 GRID POINT K.6-21.6 (N. SITE GRID) 3 97.2 23.8 94.3 701 10TH BLDG. PAD 13 GRID POINT K.7-23.8 (N. SITE GRID) 3 97.4 23.7 94.5 702 11TH BLDG. PAD 13 GRID POINT K.2-21.6 (N. SITE GRID) 1 101.4 23 96.1 703 11TH BLDG, PAD 13 GRID POINT K.2-23.7 IN. SITE GRID) 1 101.2 23 1 95.9 704 6TH BLDG. PAD 12 GRID POINT K.1-29.1 (N. SITE GRID) 4 93.1 26.6 96.2 705 6TH BLDG. PAD 12 GRID POINT K-31.6 (N. SITE GRID) 4 93.3 26.5 96.4 706 7TH BLDG. PAD 12 GRID POINT K.1-29 (N. SITE GRID) 1 99.4 23.3 94.2 707 7TH BLDG, PAD 12 GRID POINT K5-31.7 IN. SITE GRID) 1 99.1 23.1 93.9 708 8TH BLDG. PAD 12 GRID POINT K6-29.6 (N. SITE GRID) 3 97.1 23.5 94.2 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc, The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing •Environmental Servicer www.dallasfarffo.com 07ao2324 Fabens Rd. • llallas,.Texas 75225 FlAnno ❑aarsvYaenaYrs, rKe. 1'cl. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page 2 of 2 Tested For: JLB Partners, LP Date Performed: 2/8/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Test Elevation Proctor DryDensity Percent Percent No. (Lift Location No. (pcf) Moisture Density 709 8TH BLDG. PAD 12 GRID POINT K 7-31.7 (N_ SITE GRID) 3 97 23.4 94.1 710 9TH BLDG. PAD 12 GRID POINT K.6 -29.1(N. SITE GRID) 3 96.3 23.3 93.4 711 9TH BLDG_ PAD 12 GRID POINT K.3-31 (N. SITE GRID) 1 98.1 23.1 93 712 10TH BLDG. PAD 12 GRID POINT K.1-29.4 (N_ SITE GRID) 5 99.2 21.1 93.5 713 10TH BLDG PAD 12 GRID POINT K-31.6 (N SITE GRID) 5 99.3 21.3 93.6 714 11TH BLDG, PAD 12 GRID POINT K.7-29.4 (N SITE GRID) 3 96.5 23.6 93.6 715 11TH BLDG. PAD 12 GRID POINT K.6-31,6 (N. SITE GRID) 3 96.7 23.7 93.8 716 12TH BLDG_ PAD 12 GRID POINT K.1-29.7 (N SITE GRID) 1 99.3 23.1 94.1 717 12TH BLDG. PAD 12 GRID POINT K.6-31.1 (N SITE GRID) 1 99.5 23 94.3 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo �bnsult rls, Ina Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. / Test locations are referenced using an in-house system and are approximate. iG Moore, CET aterials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarffo.com