Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 2/9/2017 (3)RCRG0 2324 Fabens Rd.. Dallas, Texas 75225 rniiri., r rtsi7rr'rnK�e INC. 'rel. 214-352-4100 Fax- 214-352-4811 REPORT OF FIELD COMPACTION Page 1 oft Tested For: JLB Partners, LP Date Performed: 2/9/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth:8 Inches Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarfo.com Moisture -Density Relations Proctor No. Material Description Opt. MQ1%) Max. DD (pcfi DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 4 Dark Brown and Tan and reddish Brown CLAY (mix) 22.4 96.8 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pcf) Moisture Density 718 SG BLDG. PAD 12 GRID POINT M.5-29.4 (N. SITE GRID) 3 99.2 23.3 96.2 719 SG BLDG. PAD 12 GRID POINT M.4-31 (N. SITE GRID) 3 99.5 23.4 96.5 720 1ST BLDG. PAD 12 GRID POINT M.3-29.6 (N. SITE GRID) 1 98.8 23.4 93.6 721 1ST BLDG. PAD 12 GRID POINT M.1-31.4 (N. SITE GRID) 1 987 23.5 93.6 722 2ND BLDG. PAD 12 GRID POINT M.7-29.7 (N. SITE GRID) 4 92.9 26.4 96 723 2ND BLDG, PAD 12 GRID POINT M.2-31.3 (N. SITE GRID) 3 96.9 23.3 94 724 3RD BLDG. PAD 12 GRID POINT M.1-29.4 (N. SITE GRID) 3 96.5 23.6 93.6 725 3RD BLDG PAD 12 GRID POINT M.6-31.6 (N. SITE GRID) 3 96.7 23.5 93.8 726 4TH BLDG. PAD 12 GRID POINT M.1-29.4 (N. SITE GRID) 1 99.1 22.9 93.9 727 4TH BLDG. PAD 12 GRID POINT M,6-31.7 (N. SITE GRID) 1 99.4 23,1 94.2 728 5TH BLDG. PAD 12 GRID POINT M_7-29.6 (N. SITE GRID) 4 91.7 26.6 94.7 729 5TH BLDG, PAD 12 GRID POINT M.2-31 1 (N. SITE GRID) 4 91.9 26.5 94.9 730 SG BLDG. PAD 13 GRID POINT M-21.7 (N SITE GRID) 1 98.9 23 93.7 731 SG BLDG. PAD 13 GRID POINT M.4-23.6 (N. SITE GRID) 1 99 23.1 93.8 732 1ST BLDG. PAD 13 GRID POINT M.6-21 (N. SITE GRID) 3 96.9 23.4 94 733 1ST BLDG. PAD 13 GRID POINT M.1-23.4 (N. SITE GRID) 3 96.8 23.5 93.9 734 2ND BLDG. PAD 13 GRID POINT M.6-21.6 (N. SITE GRID) 1 98.4 23.1 93.3 735 2ND BLDG. PAD 13 GRID POINT M.7-23 (N. SITE GRID) 1 98.6 23.2 93.5 The information and results shown on this report arc for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarfo.com GO2324 Fabens Rd. • Dallas 'texas 75225 rpacao apxss.yrTnNrs, INC. Tel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page 2 of 2 Tested For: JLB Partners, LP Date Performed: 2/9/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine,, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No. (pcf) Moisture Density 736 3RD BLDG. PAD 13 GRID POINT M-21.4 (N. SITE GRID) 3 97.7 23.4 94.8 737 3RD BLDG. PAD 13 GRID POINT M,1-23.6 (N. SITE GRID) 3 97.9 23.3 95 738 4TH BLDG. PAD 13 GRID POINT M.7-21.6 (N. SITE GRID) 1 99.1 23.1 93.9 739 4TH BLDG. PAD 13 GRID POINT M.6-23,7 (N. SITE GRID) 1 98.9 23.3 93.7 740 12TH BLDG. PAD 13 GRID POINT K.4-21.6 (N. SITE GRID) 3 96.7 23.4 93.8 741 12TH BLDG. PAD 13 GRID POINT K.6-23,4 (N. SITE GRID) 3 96.5 23.3 93.6 742 12TH BLDG. PAD 13 GRID POINT K.9-21.7 (N. SITE GRID) 1 99.2 23 94 743 12TH BLDG. PAD 13 GRID POINT K-23.3 (N. SITE GRID) 1 99.4 23.1 94.2 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo anis, Inc. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximates u�y ' Q ry Moore, CET Materials Testing Division 'the information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarffo.com