HomeMy WebLinkAboutFargo Consultants, Inc. - 2/11/2017jff,MR 20 2324 Fabens Rd. • Dallas Texas 7522;. VARGO aatrsr?x°rnraxs.zrra. 'Fel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page I oft Tested For: JLB Partners, LP Date Performed: 2/11/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS -5001 EZ Probe Depth:8 Inches The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. 'fest results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Allaterials Testing • Environmental Services www.dalla.rfarffo.com Moisture -Density Relations Proctor No. Material Description Opt. MC(01o) Max. DD (pcf) DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 4 Dark Brown and Tan and reddish Brown CLAY (mix) 22.4 96.8 93 to 98 at least +4 5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8 106.1 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pcfi Moisture Density 782 SG BLDG. PAD 12 GRID POINT 0.2-28.7 (N. SITE GRID) 1 982 23.4 93.1 783 SG BLDG. PAD 12 GRID POINT 0.4-31.1 (N. SITE GRID) 1 99 23 93.8 784 SG BLDG. PAD 13 GRID POINT 0.1-21.5 (N. SITE GRID) 1 99.3 23.6 94.1 785 SG BLDG. PAD 13 GRID POINT 0.5-24.4 (N. SITE GRID) 1 98.8 23.4 93.6 786 13TH BLDG. PAD 12 GRID POINT 0.4-28.7 (N. SITE GRID) 4 91.2 26.5 94.2 787 13TH BLDG. PAD 12 GRID POINT 0.4-31.4 (N. SITE GRID) 4 91 3 26.4 94.3 788 1ST BLDG. PAD 12 GRID POINT 0.6-28.1 (N. SITE GRID) 5 100.2 21.4 94.4 789 1ST BLDG, PAD 12 GRID POINT 0.1-31.6 (N. SITE GRID) 5 100.5 21,1 94.7 790 2ND BLDG. PAD 12 GRID POINT 0-28 (N. SITE GRID) 3 97.2 23.5 94.3 791 2ND BLDG. PAD 12 GRID POINT 0.3-31.1 (N. SITE GRID) 3 96.9 23.7 94 792 1ST BLDG. PAD 13 GRID POINT 0.8-21.7 (N. SITE GRID) 4 92.3 26.6 95.4 793 1ST BLDG. PAD 13 GRID POINT 0.1-24.4 (N. SITE GRID) 4 92.4 26.4 95.5 794 2ND BLDG. PAD 13 GRID POINT 0.3-21.9 (N. SITE GRID) 1 99.2 23.1 94 795 2ND BLDG. PAD 13 GRID POINT 0.1-24.4 (N. SITE GRID) 1 99.4 22.9 94.2 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. 'fest results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Allaterials Testing • Environmental Services www.dalla.rfarffo.com =1,C70 SARCiA CON9i71.7C1111r'tB,.T•'NO. REPORT OF FIELD COMPACTION Tested For: JLB Partners, LP Project Name: Grapevine Bluff Apartments 2324 Pabens Rd. • Dallas, Texas 75225 Tcl. 214-352-4100 Pax. 214-352-4811 Page 2 of 2 Date Performed: 2/11/2017 Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-50OIEZ Probe Depth:8 Inches Source of Compaction Requirements: Geotechnical Report Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. Respectfully Submitted, Fargo�E'onsrrl nis, Inc. Ga Moores, T aterials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services w2vw. dallasfaroo. com