Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 2/16/2017i ■ �O 2324 Fabcns Rd- • Dallas . Texas 75225 �F F,A rl.r.0 C, ON Sxn.rnxTs, tx❑ "Pel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page 1 oft Tested For: JLB Partners, LP Date Performed: 2/16/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M 16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth:8 Inches Moisture -Density Relations Proctor No. Material Description Opt. MQ0%) Max DD (pcfl DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8 106.1 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pcf) Moisture Density 852 6TH BLDG. PAD 12 GRID POINT Q.3-31.7 (N. SITE GRID) 1 101.4 23.1 96.1 853 7TH BLDG. PAD 12 GRID POINT Q 4-31 (N SITE GRID) 5 102.1 21.3 962 854 6TH BLDG. PAD 12 GRID POINT Q.1-281 (N SITE GRID) 1 101.6 23.3 963 855 7TH BLDG. PAD 12 GRID POINT Q.3-28.5 (N SITE GRID) 3 99.8 24.2 96.8 856 8TH BLDG. PAD 12 GRID POINT Q.7-31.9 (N. SITE GRID) 5 102.3 21.1 96.4 857 9TH BLDG. PAD 12 GRID POINT Q.3-31.6 (N. SITE GRID) 5 99.4 23.2 93.7 858 8TH BLDG PAD 12 GRID POINT Q.5-28.4 (N. SITE GRID) 3 98.9 235 95.9 859 9TH BLDG. PAD 12 GRID POINT Q.1-28.4 (N. SITE GRID) 5 102.8 21.6 96.9 860 11TH BLDG. PAD 12 GRID POINT Q.7-31.6 (N. SITE GRID) 5 100.8 21.4 95 861 10TH BLDG PAD 12 GRID POINT Q,3-28.7 (N. SITE GRID) 5 101.1 21 95.3 862 10TH BLDG. PAD 12 GRID POINT Q.1-31.7 (N. SITE GRID) 5 101.9 21.8 96 863 11TH BLDG. PAD 12 GRID POINT 0.7-28 1 (N SITE GRID) 5 1005 21.9 94.7 864 SG BLDG PAD 13 GRID POINT Q.3-21.7 (N. SITE GRID) 3 96.9 23.9 94 865 1ST BLDG. PAD 13 GRID POINT Q.1-23.6 (N. SITE GRID) 5 98.7 21.4 93 866 2ND BLDG. PAD 13 GRID POINT Q.7-22 (N. SITE GRID) 5 99.2 22.7 93.5 867 3RD BLDG. PAD 13 GRID POINT Q.3-23.6 (N. SITE GRID) 5 101.2 21.8 95.4 868 4TH BLDG, PAD 13 GRID POINT Q.7-21.4 (N. SITE GRID) 5 99.2 21.6 93.5 869 5TH BLDG. PAD 13 GRID POINT Q-23 (N. SITE GRID) 5 98.7 21.4 93 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. 'Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Semices www.dallasfamo.com 2324 Pabens Rd. - Dallas Texas 7522: �anesoaanrsvi rnxrs,.ztrc Tel. 214-352-4100 Pax. 214-352-4811 REPORT OF FIELD COMPACTION Page 2 of 2 Tested For: JLB Partners, LP Date Performed: 2/16/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Test Elevation Proctor DryDensity Percent Percent No. IL ft Location No. (pcfi Moisture Density 870 6TH BLDG. PAD 13 GRID POINT Q.1-22.4 (N. SITE GRID) 3 97.2 23.9 94.3 871 7TH BLDG. PAD 13 GRID POINT Q.3-216 IN SITE GRID) 5 101.4 21.2 95.6 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo 11s7 t Is, Inc. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. 1_1e' G Moore, CET i aterials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing •Environmental Servicer www.dallasfarpo.com