Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 2/18/2017, KO Fh7tRiq Cofv ~: Ux:rA'N7fi. INC. 2324 Pabens Rd. - Dallas, Texas 7522; Tel. 214-352-4100 Pax. 214-352-4811 REPORT OF FIELD COMPACTION Page 1 oft Tested For: JLB Partners, LP Date Performed: 2/18/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Moisture -Density Relations Proctor No. Material Description Opt MC(%) Max DD (pcfi DD Range (%) MC Range 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8 106.1 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pc -0 Moisture Density 899 8TH BLDG. PAD 17 GRID POINT K.2-14 (S. SITE GRID) 5 99.9 21.2 94.2 900 8TH BLDG, PAD 17 GRID POINT L.4-14.3 (S. SITE GRID) 5 99.8 22.9 94.1 901 9TH BLDG. PAD 17 GRID POINT K.3-14.4 (S. SITE GRID) 3 99.5 23.4 96.5 902 10TH BLDG, PAD 17 GRID POINT K.1-14.7 (S. SITE GRID) 3 98.1 24.2 952 903 9TH BLDG. PAD 17 GRID POINT L.3-142 (S. SITE GRID) 3 97.1 24.8 94.2 904 10TH BLDG, PAD 17 GRID POINT L.414.3 (S SITE GRID) 3 96.9 24.6 94 905 11TH BLDG. PAD 17 GRID POINT K.6-14.1 (S. SITE GRID) 5 98.7 22.8 93 906 12TH BLDG. PAD 17 GRID POINT K.1-14.7 (S SITE GRID) 3 96.2 23.8 93.3 907 11TH BLDG, PAD 17 GRID POINT L.7-14.1 (S. SITE GRID) 5 100.3 21.3 94.5 908 12TH BLDG. PAD 17 GRID POINT L.3-14.3 (S. SITE GRID) 3 96.5 23.3 93.6 909 13TH BLDG. PAD 17 GRID POINT K 1-14 7 (S. SITE GRID) 5 101.4 21.8 95.6 910 13TH BLDG. PAD 17 GRID POINT K.3-14 1 (S. SITE GRID) 5 102.2 22.3 96.3 911 3RD BLDG. PAD 14 GRID POINT W.5-20.3 (N. SITE GRID) 5 100.9 21.1 95.1 912 4TH BLDG. PAD 14 GRID POINT W.4-20 4 (N SITE GRID) 3 97.9 23.9 95 913 31RD BLDG. PAD 14 GRID POINT V.1-21.1 (N SITE GRID) 5 100.4 21.5 94.6 914 4TH BLDG. PAD 14 GRID POINT V.3-21.5 (N. SITE GRID) 5 99.6 22.5 93.9 915 5TH BLDG. PAD 14 GRID POINT W.7-20.4 (N. SITE GRID) 5 100.7 21.7 94.9 916 5TH BLDG, PAD 14 GRID POINT V.1-21.9 (N. SITE GRID) 3 96.9 24.5 94 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Gevtechraicul Engineering • Construction Materials Testilag •Environmental Servicer www.dallasfarffo.com ■ ■o_700 2324 Fabens Rd. • Dallas, Texas 7522; FAnGo com;su3,XALi1r$, MC. Tel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page 2 of 2 Tested For: JLB Partners, LP Date Performed: 2/18/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS -5001 EZ Probe Depth:8 Inches Test Elevation Proctor DryDensity Percent Percent No. ILift Location No. (pct Moisture Density 917 6TH BLDG. PAD 14 GRID POINT V.3-21.6 (N SITE GRID) 3 97.6 23.6 94.7 918 6TH BLDG PAD 14 GRID POINT W.7-20.7 (N. SITE GRID) 3 96.7 23.8 93.8 919 7TH BLDG. PAD 14 GRID POINT W.4-20.4 (N. SITE GRID) 3 96.6 24.8 93.7 920 7TH BLDG. PAD 14 GRID POINT V.1-21.7 (N. SITE GRID) 3 96.1 24.4 93.2 921 8TH BLDG. PAD 14 GRID POINT W.3-20 3 (N, SITE GRID) 3 98.9 24.5 95.9 922 8TH BLDG. PAD 14 GRID POINT V.1-21.4 (N. SITE GRID) 3 99.3 24.2 96.3 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo C Fzsullaj4v, Inc. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. gre, CET ?'6.0. Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallas[ar,eo.com