Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 2/25/2017mojZO2324 Fabens Rd. - 1)nllws,.Texas 75225 rA=0,t;0V9tr=AUV.s, xrra.-1-cl.. 214-352-4100 1 pax. 214-352-4811 REPORT OF FIELD COMPACTION Page 1 of Tested For: JLB Partners, LP Date Performed: 2/25/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarffo.com Moisture -Density Relations Proctor No. Material Description Opt. MC(Yo) Max. DD (pcfi DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 2 Light Gray CLAYEY SAND and gravel intermixed 10.2 116.4 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 4 Dark Brown and Tan and reddish Brown CLAY (mix) 22.4 96.8 93 to 98 at least +4 5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8 106.1 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pcf) Moisture Density 1077 11TH BLDG. PAD 17 GRID POINT K,6-9.5 (S. SITE GRID) 1 99.2 23.1 94 1078 11TH BLDG. PAD 17 GRID POINT M.1-9,1 (S. SITE GRID) 1 99.5 22.9 94.3 1079 12TH BLDG. PAD 17 GRID POINT K.6-9 6 (S. SITE GRID) 3 97.2 23.5 94.3 1080 12TH BLDG PAD 17 GRID POINT M-9.3 (S. SITE GRID) 3 97.6 23.3 94.7 1081 SG BLDG. PAD 17 GRID POINT K.4-7.4 (S. SITE GRID) 4 92.3 26.7 95.4 1082 SG BLDG. PAD 17 GRID POINT M.6-9.8 (S. SITE GRID) 5 100.1 21.2 94.3 1083 13TH BLDG. PAD 17 GRID POINT K.1-9.4 (S. SITE GRID) 5 100.2 21.1 94.4 1084 13TH BLDG. PAD 17 GRID POINT M.1-7.4 (S_ SITE GRID) 4 91.8 26.6 94.8 1085 13TH BLDG. PAD 14 GRID POINT S 6-15 6 (N. SITE GRID) 2 110.3 14.6 94.8 1086 13TH BLDG. PAD 14 GRID POINT U.9-15.4 (N SITE GRID) 2 110.4 14.5 94.8 1087 SG BLDG. PAD 14 GRID POINT S-14.5 (N. SITE GRID) 1 99.3 23 94.1 1088 SG BLDG. PAD 14 GRID POINT T.7-14.7 (N. SITE GRID) 3 97.1 23.6 94.2 1089 1ST BLDG. PAD 14 GRID POINT T.4-14.7 (N. SITE GRID) 1 99.1 23.2 93.9 1090 1ST BLDG. PAD 14 GRID POINT S-14.5 (N. SITE GRID) 1 101.3 23.2 96 1091 2ND BLDG. PAD 14 GRID POINT T.6-14.6 (N. SITE GRID) 1 101.4 23.1 96.1 1092 2ND BLDG. PAD 14 GRID POINT S,1-14.4 (N. SITE GRID) 3 97.3 23.5 94.4 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarffo.com V 0 REPORT OF FIELD COMPACTION Tested For: JLB Partners, LP Project Name: Grapevine Bluff Apartments 2324 Fabens Rd. - Dallas, Texas 7522: Tel. 214-352-4100 Fax. 214-352-4811 Page 2 of 2 Date Performed: 2/25/2017 Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo CoysuItrrrrt , Inc. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines - Test locations are referenced using an in-house system and are approximate. G +Ga?erlals oore, CET ' Mu Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallaifarigo.com