HomeMy WebLinkAboutFargo Consultants, Inc. - 3/17/2017�00 e TAR00i CA 0AUX TA NTS. Inc. 2324 Fabcns Rd. • Dallas,'1'exas 7522; 'Tel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page 1 of 1 Tested For: JLB Partners, LP Date Performed: 3/17/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Moisture -Density Relations Proctor No. Material Description Opt. MC(%) Max DD (pcfi DD Range (%) MC Range 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8 106.1 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. ILift Location No (pcfi Moisture Density 1539 9TH BLDG. PAD 9 GRID POINT S.1-46.4 (N. SITE GRID) 3 97.7 23.5 94.8 1540 10TH BLDG. PAD 9 GRID POINT S.7-46.9 (N. SITE GRID) 5 99.4 22.2 93.7 1541 9TH BLDG, PAD 9 GRID POINT S.5-45.1 (N. SITE GRID) 5 99.9 20.9 94.2 1542 10TH BLDG. PAD 9 GRID POINT S.3-45.4 (N. SITE GRID) 3 98.2 23.3 95.2 1543 11TH BLDG. PAD 9 GRID POINT S1-46.6 (N. SITE GRID) 5 99.4 21.9 93.7 1544 12TH BLDG. PAD 9 GRID POINT S_1-46.4 (N. SITE GRID) 3 98.6 23.3 95.6 1545 11TH BLDG. PAD 9 GRID POINT S.5-45 9 (N SITE GRID) 5 99.1 22 93.4 1546 12TH BLDG. PAD 9 GRID POINT S.6-45.4 (N. SITE GRID) 5 100.6 21.7 94.8 1547 13TH BLDG. PAD 9 GRID POINT S.7-46.4 (N. SITE GRID) 5 101.2 21.2 95.4 1548 13TH BLDG. PAD 9 GRID POINT S.5-45.6 (N. SITE GRID) 5 100.7 20.8 94.9 1549 13TH BLDG. PAD 9 GRID POINT V.3-41.7 (N. SITE GRID) 3 99.2 235 96.2 1550 13TH BLDG. PAD 9 GRID POINT U.5-42.1 (N. SITE GRID) 3 98.6 23.3 95.6 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo gonsuftants, Inc. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. A�� Ga Moore, CET A aterials Testing Division The information and results shown on th s report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing •Environmental Servicer www.dallasfar,7o.com