HomeMy WebLinkAboutFargo Consultants, Inc. - 3/20/2017F. q0 2324 Fabens Rd. • Dallas, Texas 7522: VARGO CONfgUIXAWT4,siva. M TcL 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page 1 of 2 Tested For: JLB Partners, LP Date Performed: 3/20/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth:8 Inches The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. 'fest results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials "Testing • Environmental Services www. dallasfarffo. com Moisture -Density Relations Proctor No. Material Description Opt. MC(Yo) Max. DD (pcfi DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 4 Dark Brown and Tan and reddish Brown CLAY (mix) 22.4 96.8 93 to 98 at least +4 5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8 106.1 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pcfi Moisture Density 1559 4TH BLDG. PAD 10 GRID POINT T.6-40 1 (N. SITE GRID) 3 96.6 24.2 93.7 1560 5TH BLDG PAD 10 GRID POINT T.1-40.6 (N. SITE GRID) 4 91.9 26.5 94.9 1561 4TH BLDG PAD 10 GRID POINT T.7-41 7 (N. SITE GRID) 3 96.1 24.6 93.2 1562 5TH BLDG PAD 10 GRID POINT T 4-41 1 (N. SITE GRID) 3 97 23.9 94.1 1563 6TH BLDG PAD 10 GRID POINT T.6-40.6 (N. SITE GRID) 3 98.9 23.6 95.9 1564 7TH BLDG. PAD 10 GRID POINT T.3-40.1 (N. SITE GRID) 5 100.3 22.2 94.5 1565 6TH BLDG. PAD 10 GRID POINT T.1-41.7 (N. SITE GRID) 5 99.6 21.4 93.9 1566 7TH BLDG PAD 10 GRID POINT T.7-41.6 (N. SITE GRID) 3 99.2 24.8 96.2 1567 8TH BLDG PAD 10 GRID POINT T.6-40 4 (N SITE GRID) 1 99.6 22.9 94.4 1568 9TH BLDG PAD 10 GRID POINT T 4-40.6 (N SITE GRID) 5 98.8 21.7 93.1 1569 8TH BLDG PAD 10 GRID POINT T 6-41.1 (N. SITE GRID) 1 98.9 23.3 93.7 1570 9TH BLDG PAD 10 GRID POINT T 7-41.1 (N SITE GRID) 3 98.1 23.7 95.2 1571 10TH BLDG. PAD 10 GRID POINT T 1-40 7 (N SITE GRID) 3 98.3 24.4 95.3 1572 11TH BLDG. PAD 10 GRID POINT T.6-40 6 (N SITE GRID) 3 97.6 24.8 94.7 1573 10TH BLDG. PAD 10 GRID POINT T.4-41 1 (N. SITE GRID) 3 96.8 23.9 93.9 1574 11TH BLDG. PAD 10 GRID POINT T.6-41 (N. SITE GRID) 3 96.2 25.1 93.3 1575 12TH BLDG. PAD 10 GRID POINT T.1-40 6 (N SITE GRID) 4 91.7 27.2 94,7 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. 'fest results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials "Testing • Environmental Services www. dallasfarffo. com F.�3G0 2324 1 �abens Rd. • Dallas Texas 75225 FAACid'CrOW SIOLTRb TS. INN, Tel. 214-352-4100 Fax. 214-352-4811 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo ons !tants, Inc. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. G Moore, CET iaterials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarffo.com REPORT OF FIELD COMPACTION Page 2 of 2 Tested For: JLB Partners, LP Date Performed: 3/20/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Gra evine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Test Elevation Proctor DryDensity Percent Percent ILift Location No. (pcf) Moisture Density, No. 1576 12TH BLDG. PAD 10 GRID POINT T.6-41.7 (N. SITE GRID) 4 92.9 26.8 96 1577 SG BLDG. PAD 9 GRID POINT R.7-44.6 (N. SITE GRID) 3 96.7 23.5 93.8 1578 SG BLDG PAD 9 GRID POINT Q.6-45.1 (N. SITE GRID) 3 97.1 23.9 94.2 1579 1ST BLDG. PAD 9 GRID POINT R.3-44.7 (N. SITE GRID) 1 98.8 23.2 93.6 1580 2ND BLDG. PAD 9 GRID POINT R-44 6 (N. SITE GRID) 3 98 23.3 95.1 1581 1ST BLDG, PAD 9 GRID POINT Q.1-45.1 (N. SITE GRID) 3 97.6 23.7 94.7 1582 2ND BLDG. PAD 9 GRID POINT Q.6-45 (N. SITE GRID) 1 98.5 23.4 93.4 1583 3RD BLDG. PAD 9 GRID POINT R.1-44.7 (N. SITE GRID) 3 96.6 24.4 93.7 1584 4TH BLDG. PAD 9 GRID POINT R.7-44.6 (N. SITE GRID) 3 97.1 24 94.2 1585 3RD BLDG. PAD 9 GRID POINT Q-45.1 (N. SITE GRID) 3 97.7 23.6 94.8 1586 4TH BLDG. PAD 9 GRID POINT Q.6-45.6 (N. SITE GRID) 3 96.1 24.7 93.2 1587 5TH BLDG. PAD 9 GRID POINT R.1-44.7 (N. SITE GRID) 5 99.1 22.4 93,4 1588 6TH BLDG. PAD 9 GRID POINT R.9-44.6 (N. SITE GRID) 5 995 22.1 93.8 1589 5TH BLDG. PAD 9 GRID POINT Q,1-45.1 (N. SITE GRID) 1 98.6 23 93.5 1590 6TH BLDG. PAD 9 GRID POINT Q-45,8 (N. SITE GRID) 5 98.8 22.9 93.1 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo ons !tants, Inc. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. G Moore, CET iaterials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarffo.com