Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 3/22/2017Lf�aGO A^ 2324 Fabens Rd. • Dallas, Texas 75225 rnxusn Cbxgvr rAtr'crc. tnrC: i'cl. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Pagel oft Tested For: JLB Partners, LP Date Performed: 3/22/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Moisture -Density Relations Proctor No. Material Description Opt. MC(Yo) May- DD (pcj) DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8 106.1 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pcfi Moisture Density 1611 13TH BLDG. PAD 9 GRID POINT R.8-44.4 (N. SITE GRID) 1 98.8 22.9 93.6 1612 13TH BLDG. PAD 9 GRID POINT Q-45 (N. SITE GRID) 3 98.6 23.3 95.6 1613 SG BLDG, PAD 9 GRID POINT P.6-44.6 (N SITE GRID) 1 99.9 23.5 94.7 1614 1ST BLDG. PAD 9 GRID POINT P.444.7 (N. SITE GRID) 5 101.4 21.8 95.6 1615 2ND BLDG. PAD 9 GRID POINT P.644.4 (N. SITE GRID) 5 102.2 22.1 96.3 1616 3RD BLDG. PAD 9 GRID POINT P-44.6 (N. SITE GRID) 5 100.9 21.6 95.1 1617 4TH BLDG. PAD 9 GRID POINT P.144.1 (N. SITE GRID) 1 99.5 24.2 94.3 1618 5TH BLDG, PAD 9 GRID POINT P.644,9 (N. SITE GRID) 3 98.4 23.3 95.4 1619 6TH BLDG. PAD 9 GRID POINT P.1-44.2 (N. SITE GRID) 5 100.3 22.2 94.5 1620 7TH BLDG. PAD 9 GRID POINT P.7-44.7 (N. SITE GRID)V 5 100.8 21.1 95 1621 8TH BLDG, PAD 9 GRID POINT P.644.6 (N. SITE GRID) 5 98.9 23.9 93.2 1622 9TH BLDG. PAD 9 GRID POINT P-44.1 (N. SITE GRID) 5 99.4 23.5 93.7 1623 7TH BLDG. PAD 10 GRID POINT R.4-40.1 (N. SITE GRID) 3 97.6 24.8 94.7 1624 8TH BLDG. PAD 10 GRID POINT R.6-40 (N. SITE GRID) 3 98.4 24.2 95.4 1625 9TH BLDG. PAD 10 GRID POINT R.4-39,1 (N. SITE GRID) 1 982 23.3 93.1 1626 10TH BLDG. PAD 10 GRID POINT R 9-39.7 (N. SITE GRID) 5 100.3 21.9 94.5 1627 11TH BLDG. PAD 10 GRID POINT R.7-40.9 (N. SITE GRID) 3 96.2 25 93.3 1628 12TH BLDG. PAD 10 GRID POINT R.6-40.6 (N. SITE GRID) 3 97.9 24.8 95 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on File in our office. fest results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Servicer www.dallasfarFo.com r 107 F'ARCiDrNC, 2324 Fabens Rd. +'.Dallas Tcxas 7522; Tel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page oft Tested For: JLB Partners, LP Date Performed: 3/22/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-50OIEZ Probe Depth:8 Inches Test Elevation Proctor DryDensity Percent Percent No. (Lift Location No. (Pcf) Moisture Density 1629 13TH BLDG. PAD 10 GRID POINT R.4-40.4 (N. SITE GRID) 1 98.4 23.4 93.3 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo onsultants, lift. Test result with asterisk(*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. t}+ Moore, CET Materials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarffo.com