Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 3/29/2017 (2)W?C7V 2324 Pabcns Rd. - Dallas,.'1'cxas 7522; FnRcOGGGG canrsvixnara s, rmo. 'Tel. 214-352-4100 Pax. 214-352-4811 REPORT OF FIELD COMPACTION Page I oft Tested For: JLB Partners, LP Date Performed: 3/29/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth:8 Inches The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. 'fest results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services avww.dallarfarpo.com Moisture -Density Relations Proctor No. Material Description Opt. MC(%) Max DD (pcfi DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 4 Dark Brown and Tan and reddish Brown CLAY (mix) 22.4 96.8 93 to 98 at least +4 5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8 106.1 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pcf) Moisture Density 1732 2ND BLDG, PAD 16 GRID POINT Y.5-18.2 (S. SITE GRID) 4 92,6 26.9 95.7 1733 3RD BLDG. PAD 16 GRID POINT Y.1-18.1 (S. SITE GRID) 3 96.8 25 93.9 1734 4TH BLDG. PAD 16 GRID POINT Y.6-18.7 (S. SITE GRID) 4 91 8 26.5 94.8 1735 5TH BLDG. PAD 16 GRID POINTY.1-18.1 (S SITE GRID) 3 977 24.6 94.8 1736 6TH BLDG. PAD 16 GRID POINT Y.2-18.4 (S. SITE GRID) 1 982 24 93.1 1737 7TH BLDG. PAD 16 GRID POINT Y.6-18.6 (S. SITE GRID) 4 92.8 26.6 95.9 1738 8TH BLDG. PAD 16 GRID POINT Y.7-18 (S. SITE GRID) 3 98 24 95.1 1739 9TH BLDG PAD 16 GRID POINT Y.5-18.7 (S. SITE GRID) 3 96.2 24.6 93.3 1740 10TH BLDG PAD 16 GRID POINT Y.1-18,5 (S. SITE GRID) 3 97.9 24.1 95 1741 11TH BLDG. PAD 16 GRID POINT Y-18 4 (S SITE GRID) 3 96.6 28.6 93.7 1742 12TH BLDG, PAD 16 GRID POINT Y.1-18.6 (S SITE GRID) 3 97.2 23.4 94.3 1743 13TH BLDG. PAD 16 GRID POINT Y.6-18.4 (S. SITE GRID) 1 98.9 23.2 93.7 1744 2ND BLDG. PAD 8 GRID POINT P.7-50 7 (N. SITE GRID) 3 97.6 24.1 94.7 1745 3RD BLDG, PAD 8 GRID POINT P.1-50.6 (N SITE GRID) 4 93.1 26.6 96.2 1746 4TH BLDG. PAD 8 GRID POINT P.6-50.2 (N. SITE GRID) 3 97.2 23.8 94.3 1747 5TH BLDG. PAD 8 GRID POINT P.7-50.7 (N. SITE GRID) 1 98.6 23.5 93.5 1748 6TH BLDG. PAD 8 GRID POINT P.4-50.3 (N. SITE GRID) 5 98.8 23.8 93.1 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. 'fest results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services avww.dallarfarpo.com F■ ■� 2324 Fabens Rd. Dallas, '1'cxas 75225 anntaa 0ONSIMTANTS.INa. Tel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page 2 of 2 Tested For: JLB Partners, LP Date Performed: 3/29/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Test Elevation Proctor DryDensity Percent Percent No. ILift Location No. (pcfi Moisture Density 1749 7TH BLDG. PAD 8 GRID POINT P.6-50.7 (N. SITE GRID) 5 100.4 22.4 94.6 1750 8TH BLDG. PAD 8 GRID POINT P.2-50.5 (N. SITE GRID) 5 98.7 23.3 93 1751 9TH BLDG. PAD 8 GRID POINT P.4-50.1 (N. SITE GRID) 5 99.3 22.6 93.6 1752 10TH BLDG. PAD 8 GRID POINT P.6-50.7 (N. SITE GRID) 5 99.4 21.9 93.7 1753 11TH BLDG, PAD 8 GRID POINT P.4-50 (N. SITE GRID) 5 98.9 22.4 93.2 Source of Compaction Requirements: Geotechnical Report Respectfully Submitted, Fargo Consultants, Inc. Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. Moore, CET 4tera ialss Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineeiin,g • Construction Materials Testing • Environmental Services www.dallasfarFo.com