Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 3/31/2017 (2)FAn cin a o zqn u a,rA tNOC 2324 Fabens Rd. - Dallas, Texas 7522; Tel. 214-352-4100 Fax. 214-352-4811 REPORT OF FIELD COMPACTION Page 1 of Tested For: JLB Partners, LP Date Performed: 3/31/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or sirrlar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarffo.com Moisture -Density Relations Proctor No. Material Description Opt. MC(%) Max DD (pcfi DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 4 Dark Brown and Tan and reddish Brown CLAY (mix) 22.4 96.8 93 to 98 at least +4 5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8 106.1 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pcfl Moisture Density 1778 SG BLDG- PAD 15 GRID POINT H.8-15.5 (N. SITE GRID) 1 99,3 23.6 94.1 1779 1ST BLDG. PAD 15 GRID POINT H-15.2 (N, SITE GRID) 1 99 24.2 93.8 1780 2ND BLDG. PAD 15 GRID POINT H.4-15.2 (N SITE GRID) 1 100.1 24.5 94.9 1781 3RD BLDG. PAD 15 GRID POINT H.6-15.4 (N. SITE GRID) 1 99.4 23.1 94.2 1782 4TH BLDG_ PAD 15 GRID POINT H.1-15.6 (N. SITE GRID) 1 98.7 22.9 93.6 1783 5TH BLDG. PAD 15 GRID POINT H.6-15.7 (N. SITE GRID) 1 101.2 23.2 95.9 1784 6TH BLDG. PAD 15 GRID POINT H.7-15.5 (N. SITE GRID) 3 96.3 24 93.4 1785 7TH BLDG. PAD 15 GRID POINT H.2-15.7 (N. SITE GRID) 3 97.5 23.8 94.6 1786 8TH BLDG. PAD 15 GRID POINT H.6-15.4 (N. SITE GRID) 4 92.8 26.5 95.9 1787 9TH BLDG. PAD 15 GRID POINT H.1-15.1 (N. SITE GRID) 3 96.1 24.2 93.2 1788 8TH BLDG. PAD 8 GRID POINT R-51 (N. SITE GRID) 3 98.7 23.7 95.7 1789 9TH BLDG. PAD 8 GRID POINT R.6-51.6 (N. SITE GRID) 5 99.5 21 93.8 1790 10TH BLDG. PAD 8 GRID POINT R.7-51.4 (N. SITE GRID) 3 97.6 24.3 94.7 1791 11TH BLDG. PAD 8 GRID POINT R-51.6 (N. SITE GRID) 5 99.2 21.7 93.5 1792 12TH BLDG. PAD 8 GRID POINT R.3-51.7 (N. SITE GRID) 5 98.9 22.4 93.2 1793 13TH BLDG. PAD 8 GRID POINT R.7-51.6 (N. SITE GRID) 5 99.8 21.6 94.1 1794 SG BLDG. PAD 7 GRID POINT P.1-54.5 (N..SITE GRID) 1 99.2 22.9 94 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or sirrlar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarffo.com F�1Ga i-' A14 GO C O118t3 INA 1N TS..TNr REPORT OF FIELD COMPACTION Tested For: JLB Partners, LP Project Name: Grapevine Bluff Apartments 2324 Pabens Rd. • Dalfas, 'Texas 75225 Tel. 214-352-4100 Pax. 214-352-4811 Page 2 of 2 Date Performed: 3/31/2017 Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches Source of Compaction Requirements: Geotechnical Report Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. Respectfully Submitted, Fargo onsultants, Inc. Ga y Moore, CET aterials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfarffo.com