Loading...
HomeMy WebLinkAboutFargo Consultants, Inc. - 4/1/2017 (2)R Rawdmn�m_ ... FARGO CONSU7.TANTS_1140. 2324 Pabens Rd. - Dallas, Texas 7522: '.1'cl. 214-352-4100 Pax. 214-352-4811 REPORT OF FIELD COMPACTION Page I oft Tested For: JLB Partners, LP Date Performed: 4/1/2017 Project Name: Grapevine Bluff Apartments Fargo Job No. M16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Gauge Model: HS-5001EZ Probe Depth: 8 Inches The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Eugiiieeriug • Construction Materials Testing • Enviroranienial Services www.dallasfarffo.com Moisture -Density Relations Proctor No. Material Description Opt. MC(Yo) Max. DD (pct DD Range (%) MC Range 1 Light Gray SANDY CLAY 18.9 105.5 93 to 98 at least +4 3 Light Gray and Tan and Brown SANDY CLAY (mix) 19.3 103.1 93 to 98 at least +4 5 Reddish Brown SANDY CLAY with Brown and Tan CLAY (mix) 16.8 106.1 93 to 98 at least +4 Field Test Results Test Elevation Proctor DryDensity Percent Percent No. /Lift Location No (pcfi Moisture Density 1795 1ST BLDG. PAD 7 GRID POINT P.4-54.7 (N SITE GRID) 3 95.9 24.2 93 1796 2ND BLDG. PAD 7 GRID POINT P-.254 5 (N. SITE GRID) 5 98.9 21.8 93.2 1797 3RD BLDG. PAD 7 GRID POINT P.3-54.2 (N SITE GRID) 5 99.4 22.2 93.7 1798 4TH BLDG. PAD 7 GRID POINT P.1-54.6 (N. SITE GRID) 5 100.5 21.3 94.7 1799 5TH BLDG. PAD 7 GRID POINT P-54.8 (N. SITE GRID) 5 99.8 21.6 94.1 1800 6TH BLDG. PAD 7 GRID POINT P.2-54.7 (N. SITE GRID) 5 100.7 20.8 94.9 1801 7TH BLDG. PAD 7 GRID POINT P.4-54 4 (N. SITE GRID) 5 98.7 22.9 93 1802 8TH BLDG, PAD 7 GRID POINT P.3-54.4 (N. SITE GRID) 5 100.3 22.4 94.5 1803 9TH BLDG. PAD 7 GRID POINT P.4-54.6 (N. SITE GRID) 5 99.6 21.8 93.9 1804 10TH BLDG, PAD 15 GRID POINT H.1-15.8 (N. SITE GRID) 1 98.8 22.9 93.6 1805 11TH BLDG. PAD 15 GRID POINT H17-15.5 (N. SITE GRID) 3 98.1 24.1 95.2 1806 12TH BLDG. PAD 15 GRID POINT H.4-15.5 (N. SITE GRID) 1 99.8 23.6 94.6 1807 13TH BLDG. PAD 15 GRID POINT H-15 4 (N. SITE GRID) 1 99.6 23.8 94.4 The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Eugiiieeriug • Construction Materials Testing • Enviroranienial Services www.dallasfarffo.com F1 ,mhlft_ FAnOO OONSVI MA N76. INC. REPORT OF FIELD COMPACTION Tested For: JLB Partners, LP Project Name: Grapevine Bluff Apartments 2324 Fabcns Rd. Dallas, Texas 7522: "1'cl. 214-352-4100 Fax. 214-352-4811 Page 2 of 2 Date Performed: 4/1/2017 Fargo Job No. M 16-4962 Grapevine, Texas Density and Moisture: Per ASTM D-6938 Gauge Manufacturer: Humboldt Test Mode: Direct Transmission Source of Compaction Requirements: Geotechnical Report Test result with asterisk (*), if any, indicates non-compliance to provided guidelines. Test locations are referenced using an in-house system and are approximate. Gauge Model: HS-500IEZ Probe Depth: 8 Inches Respectfully Submitted, Fargo �'onsrrlt nts, Inc. ti Gq;y Moore, CET Materials Testing Division The information and results shown on this report are for the exclusive use of the client and the client's designated recipients on file in our office. Test results are based on data obtained from specific samples tested at particular locations noted and are not indicative of the qualities of apparently identical or similar specimens, composition, performance, etc. The use of our name and test results must receive our written approval. Reports must be reproduced in their entirety. Geotechnical Engineering • Construction Materials Testing • Environmental Services www. daIla sfarpo. com